Loading...
30B-097 (3) 139 FEDERAL ST BP-2018-1318 GIS#: COMMONWEALTH OF MASSACHUSETTS a :Block:30B-097 CITY OF NORTHAMPTON Lot,-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Categorv,SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2018-1318 Protect# JS-2018-002344 Est Cost: $18821.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO.- Const. O.const.Class: Contractor: License: Use Group: VIVINT SOLAR DEVELOPER LLC 070940 Lot Size(sp.ft.): 9888.12 Owner: BRUMBERG MARK D&DONNA B LILBORN Zoning:URB(100)/ Applicant. VIVINT SOLAR DEVELOPER LLC AT. 139 FEDERAL ST Applicant Address: Phone: Insurance: 150 PADGETTE ST UNIT B (413)259-8044 0 WC CHICOPEEMA01022 ISSUED ON:6/14/2018 0:00:00 TO PERFORM THE FOLLOWING WORK:ROOF TOP SOLAR, 29 PANELS 8.55 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation:. Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 6/14/20180:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner Department use only City of Northampto us it: Building Departrme Cuqrbp C�Yut/D we Permit 212 Main Street �UN 1 eM Aept' Avai ability - Room 100 - Water/Well vaila ilily Northampton, MA 01 60 truci trait Plans phone 413-587-1240 Fax 41 -58 HXMPT ans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING RM SECTION 7 -SITE INFOATION r✓r'//— ( 9— / J J y 1.1 Pro e A res' \nn This section to be completed by office i�fQf V� Map �)r� Lot ` r Unit Zone Overlay District Elm SL Distrl CB Dlatrkt SECTION 2.PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Rec r C)r i rum c3 /67 F oral IJ4 Name(Pnnt) Cgjj(.yy g, tlrpyas�y/1 Telephone CJ77L� Signature 2.2 Authorized Anent: Savina Cervone 150 Padgette St, Chicopee, MA 01022 Nam M) Current Mailing Address: " 413-217-4033 Signature Telephone SECTION 3.ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by perinit applicant 1. BuiltlingORnn (a)Building Permit Fee ` 2. Electrical p{J (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) #- 5. Fire Protection 6. Total=(1 +2+3+4+5) Check Number �. This Section For Official Use Only Date Building Permit Num Issuen. Signatu Buildi ommissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Exi{ting. II( Propgsed Required by Zoning 'Ibis column to M tilled in by Building Dzpanment Lot Size -`R � Frontage Setbacks Front Side. U R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg a paved routine) M of Puking Spaces Fi1L volume&Lavation A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Wit the construction activity disturb(clearing, grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over t acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION e-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ FN.. lacement Windows Altera0on(s) ❑ Roofing ❑ oors O Accessory Bltlg. ❑ Demolition ❑ Signs [O] Decks jq�Y1 Siding[Dl Other[OJ Brief Description of Proposedp-r 'Yy�/, rk� Installation o roof mounted photovoltaic Oar psterns9 opf inodules0r7�/�� AI aro of ea stagb ro m InY o dm taco 6hdroom "V�s No Attached Narrative Renovating unfinished basement _Yes No Plans Attached Roll -Sheet ea. If New house and or addition to existing housing. Complete the following: a. Use of building:One Family Tyro Family Other It. Number of roams in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? I. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Complianceform attached? h. Type of construction I. Is construction within 100 ft. of wetlands?_Yes No. Is construction within 100 yr. floodplain_Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank_ City Sever_ Private well_ City water Supply_ SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Domer Date I, Vivint Solar Developer LLC as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Savina Cervone Pri time 6 Si ure of Owne/Agent Dike SECTION 8-CONSTRUCTION SERVICES 6.1 Licensed Construction Supervisor: Not Applicable ❑ Name of Licenea Hader John AJalbert CS070940 License Number 150 Padi=_ette St Unit B. Chicopee. MA 01022 03/25/2019 Atl ress /'� �� Expiration Date �-LOL' "t- 413-217-4033 azure Telephone 8.Registered Home Improvement Contractor. Not Applicable ❑ VIVINT SOLAR DEVELOPER LI,C/John A Ialhert 170848 Company Name Registration Number 1800 W Ashton Blvd. Lehi IIT 84043 1/4/2020 Address Expiration Date Telephone 413-217-4033 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.162,§26CSB Worsen:Compensation Insurance afidavh must be completed and submitted with this application.Failure to provide this affidavit will resWt in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... D No...... D 11. - Home Owner Exemption The current exemption for"homeowners'was extended to include Owner-occupied Dwellings,of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year Period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work Performed under the buildine permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined Qbyy MGL c 111, S 150A. Address of the work: 139 Fetre--Ml V I The debris will be transported by: ylvint solar Developer LLC The debris will be received by: yivint solar Developer LLC Building permit number: Name of Permit Applicant Savina Ce"one Date Signature of Permit Applicant The Commonwealth ofMassaehusetts UVDepartment oflndustrialAccidents Office of Investigations 1 Congress Street,Suite 100 Boston,MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print LeFibly Name(Businms/OrganlzadoNindividu 1): Vivint Solar, Inc. Address: 1800 W Ashton Blvd. City/State/Zi Phone#: apl-3 -Q111 Are you in employer? Check the appropriate box: Type of project(required): LAO I am a employer with 253 4. ❑ 1 am a general contractor and 1 6. ❑New construction employees(full and/or part-time)." have hired the sub-contractors 2.❑ f am a sole proprietor or partner- listed on the attached aheeL 7. ❑Remodeling ship and have no employees These sub-contractors have g, ❑Demolition working for me in any capacity. employees and have workersy ❑ Building addition [No workers' comp.insurance comp.insurance t required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required] t c. 152,§1(4),and we have no employees. [No workers 13.[Z Odrergola[.installation comp. insurance required.] 'Any upplw mt that checks Mx al must atm rill wt ac section below showing drcir wwkm'om.pmsadm policy infemolion. 11W......e who submit this affidavit indicating tory we dpi,ell woh end then the..ride mmranon must mbmita nw eM&W indiutiig such. tConm,rwrs that chmk this box moat attached..additiaW sheet showing Ne name ofde sub�mtmcm.s ends w,"edxr-not th..c entitio hive empbycea. rdre su mtmnm have mplyee,they mon provide Meir wmkm'comp,policy number. Iam an employer drat isprovidbrg workers'compensation insarancefor my employees. Belowirihepolieyandjobsite information. Insurance Company Name: Zurich American Insurance Company Policy#or Self-ins, Lte.#:,WC509601302 _ _... __. Expiration Date: 11111018 JobSiteAddress: yl E / City/St te/zip 11I2" L_l,_V r / Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insumace coverage verification. Idohere6ycerdfyuaderr insandpen ' perjury arrheinformotionprovidedabove is true andcorrreM. Signature Date. phrme a and'Yr'r_ 1 Oficial use only. Do not write in this arca,to be complesedby city or town ojjicial. City or Town: Permit/Licensc it Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.CilylTown Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone s: :upntl6Mpjtd 1 MYo�t4lwwo'J x3 -.vss,,, Nol winos "��.�1141TL4Y 4L avmww 4 NMox lO4�N4tl+14 YOI,}'lNytYVj MKLPp :44u4411 ltl4 44 "MmeW summs N p"" Q A WI SW4 N wow'W4tlw 4w�v Mvy em" l(1'lN l ° tlB NojM6Y'PAOWI 1d3SN'PNHOr �$[ WV-*G INIMn o4o:ndw "' C anew! wa a+u Wolv4Wtwoa lxnunrn+m aaaN uapx4lay pM4n1a 4 4Ryp pYIMYe7 M 4B4+a tp Acd lY CERTIFICATE OF LIABILITY INSURANCE anvz0n TMS CERTNTCATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER,TMS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EITEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORRED REPRESENTAT OR PROP ER,MOTHS CERTIFICATE HOLDER, IMPORTANT; If Me CartlficeN holder ie an ADDITIONAL INSURED,Me policy(les)must lava ADDITIONAL INSURED proIRM.of ba endM.d. N SUBROGATION IS WAIVED,s ati to Me term.and C.hMcV.of Ma policy,certeln polities may require an inc orsepal A staroment on ibis ofewhicaM does Me C4MaT ii"he the cafF.Ou haMeT m fpu N arch andarsarnxd(.). PROWCM MARSH OSA IN6 Meal 1226RTHSSEET SURE i?Of (PNC, "rAyn _- - MITDURVERDen CU&M-U6.1tyyLB°'E>a: ;A'oxY .AIIn.OenvtX.ConRryuuaYmarsM1.mlr'I Far.212-9AB11@1 IX&1RYIISl4ParmIXUaOVEMOE I XyC1 _._. . __ W&NIERt'rWS SVec=syE .4e rN.Uano Ianac Company 116535 V pIS91dl l6C NYJnE O-2AVLM1 Amtl YB 1 VW4Soon P bptll l,LC N4 C-Apgr14 Z [t,L6IDrMGC C:,e4dny I4@142 15MTw AsA,I.Nim mus - Lonp UT 34pg3eVRefl NIIvNators ln6urarcgcyme@nY IO9U] Wei F: COVERAGES CERTIFICATE NUMBER: SEATI03174I2245 REVISION NUMBER: 5 THIS IS TO CERTIFY THAT THE POLICIE6 OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD VMECAi ED. NOTYATHSTANOWG ANY REOLAMMENT, TERM OR COMMON CF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIN CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIM"SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPIN. BaIaRAVLE MItYW 4 POLCI'EFF Iea.CYEXP-1 _.... (.a{g - A % COYYERCUL4ENERALWBWr 111AJ1E111EN IIIliP91p1] I1101[C1B 1... _ ,E40 IOAMAGETORFMfO MOCCUNRENCE s 10]C.WII cLMMsmaIM XjPCCuv —— IPREw$E3AE9w- 1 SP) ri ,Cm,Pa0'1 CMEO(U!"'M rev_ml _b IOFW PER$0NAL&YOV INJURY 1 - - rrZN1,0110 GEN'LY,GtE4n*E W APPLiEix_n: j — _CL I NRryO iGENC0.0 uR^AeiE 5 20JN9P� . JJECY '_ ..— % I POLL.v lUG i_PRODNLTS-COMPICPAVG 18 _LWO,OW fl IALLTC4CBafiLtSaXlry CSAPSQ96GIW3 IItIO::A: IIAl1N1T8 AEO EUW �(€T_T,ffiel S I,NCJW x ANY AUnJ �.SJULYINJu YY;,Am Ib �ow»Ea 'scnmlmen —. ICS PNa -aJ 0.µ ( �BQON, YtPweviM.tY�b NOrv.nwNEO E OAMA4E- s X NJT.1 oNLv % ATOS ons CLnD'LW Sea a LSU WU ' i x tmexeLMu® X I OWVH EIINttgZiffN OHHI1ClI 110PMt@ EAC OC_w_R_MICE $ 5,OOL.UW X E[CE9a WB fiL Oltl - L CIAIME-WTU y AG_GNEGATE E SiWO.OW NI T b ACNRMe%CpMFX9An Ar wCK&W190@ IADST 111 )w a N R B AND HYMAVPItl'tuaDry I _ efATlnE, 1ERX ap roRPAR EpXx..d*LVE � wC509@01a0]fMAI II1I0112B1T 11NI20@ 4Ei bract.ACCIOEne 5 1,W0 WC (J IVOReAdaN, i ONNo) EtCWUE -.E.L.M5_0A EM0.0YY641 FO1vb00@abw ICYLIMi E 0.EWEMCESSLASI11Y lll01AP7 11@1SvaFCCRAA PA� v'flW ALI'CIELONLY i IAGGRE6ATE $5,000M "YoneyigMCf OPERATONat LocATWN.IiE"ICLEB IACORUt61,AYlYbryflCnm#e3CMGva.mW 4sI1+CMKdnxro Cpo"wRCMwi CERTIFICATE HOLDER CANCELLATION No,IPampUP SHOULD MY OF THE ABOVE DESCRIBED POLICIES BE CANCF,LLED BEFORE tlB Mem SNCm THE EXNRd9mER a SAM T IDLA M6➢CE WILL BE DfllVERED N NMhamplan.MA TIMTHE EMMYPRO io". N"UNNW,Mh I3®pPRE.ENTFTM Ci US{Ye. Kathl6eP LP.N. C IMP6 ACORD CORpORATiON, AR dghm mXRWM. ACOR025(MIG/03) The ACORD name and logo are registered Mar"of ACOND ton viva nta 800 Lehi, UT 8840 3 Structural Group J.Matthew Walsh, SE,PE Jon P. Ward, SE,PE Senior Structural Engineering Manager Structural Engineering Manager james.wajsh@vlvinfsolar.com jon.wardtdvivintsolarcom June 12, 2018 Re: Structural Engineering Services Brumberg Residence 139 Federal St, Northampton, MA S-5888934; MA-04 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the root of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches,and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence is typical wood framing construction with rolled asphalt and a maximum of two layers of composite shingle roofing. All wood material utilized for the root system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components and consists of the following: • Roof Sections (1 and 2): Dimensional lumber - 2x6 at 24" on center. Survey photos indicate that there was free access to visually inspect the size and condition of the roof members. • Roof Sections (3 and 4): Dimensional lumber - assumed 2x6 at 16" on center. Survey photos indicate that there was not free access to visually inspect the size and condition of the roof members. B. Loading Criteria 8.49 PSF= Dead Load (roofing/framing) 2.59 PSF= Dead Load(solar panels/mounting hardware) 11.08 PSF =Total Dead Load 20 PSF = Root Live Load 40 PSF=Ground Snow Load(based on local requirements) Wind speed of 117 mph (based on Exposure Category B-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C.Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent"Unirac, Inc. Installation Manual", which can be found on the Unirac, Inc. website (www.unirac.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. Page 1 oft vivint. Page 2 of 2 2. The solar panels are 1'/"thick and mounted 4'/z"off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw(5/16"x 4'h") is 235 lbs/inch of penetration as identified in the National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir. Based on our evaluation, the pullout value, utilizing a penetration depth of 21h", is less than the maximum allowable per connection and therefore is adequate. 4. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10 and is specified below. The following values have been verified by in- house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections shall be staggered to distribute load to adjacent members. Modules in Lands ca a Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical S acin in 40 40 40 66 66 66 Max Horizontal S acin in 72 72 72 48 48 48 11 Max U lift Load lbs 218 142 80 368 1 239 135 D. Summary Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly.This evaluation is in conformance with the 2015 International Residential Code with Massachusetts Amendments,current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above,or if more information is required, please contact me. 1A4. OF Regards, $_ Jon P. Ward,SE, PE N v AR MA License No. 52584 NO. 525 ♦ 4FCIeTEaE� ♦ 0910NAL♦♦ ENGAA�Pr II RR, 06/12/2018 vivint. 1 -_- -�— - _ - - --PVsTRIOSI PV SYSTEM SLEGEND - NG151'. OFSECTIGN SYSTEMIZE ® yM16MOOMLEG ANI v] ® MFIENL4L CGMP. xEw essswwa I r666Mv nc +2IUMOOMIEs (fwG� Ixc lxlEn6n M..N 6uvcE P.EL6 z sLave.is �%x]X ixreuoxxeor..TIED IT ETUTE -MMin-� i M M>ieaw.aaLCO ACII NEN E' ®-2 WITH. CT ] SIOPE-3TERti auuttE � �. MV C] FF,,�� 1 WIN IN STEM— AAILdAP. U6 w a �GreLEE-32 HE K TF EAC.«w.] 6sM�'avry nMw ` I . X.]v MnreNlu.caMv. xEwwcaxwTUR �gEEEI.ocanw�.a reomE SII SXINGLE --]xrt6xwMux - =<nc Sux� N _—__—__—__— � �- I #x�„xxoHNw6N.M0o�,rEMmP�M� G O Q El z l o o I , a I I F Z I o I J Y W � o vivant sok co ------M-�----------0-------------- ----- ar aaa.nss LL BRGMBERG RESIDENCE 1]BFEOEPALSi WITETTliAMP TAW OULIIV CCOO] pM6Lf691N010- 4 SITE PLAN EA x��rEIWO. PV 1.01 SCALE:3116'=IV o w w J MOUNTING LEGEND <i �c cc-I C<l 115FM�9� I SFM-TRIMRAIL WITH �.. (DIF -.ROOF AgCHGMENxT I \SECTION VIEW s ROOATiACHMENT s SFM-3"RAIL (DIE sw o J x. l IILSCp SG� &q GaourvD NG lues ..,.. TD ( y� ULES IN PORT /IANDSPACE wwxu 1 ...Im,mvxe c SFM LAYOUT ,Mw, a SFM-9"SPLICE sin M�� .r.r vivint-Solar mrs, BR UMBERG RESIDENCE ,.,.,. iue reoeRu s. IM MOUNTING DETAIL //\PV SYSTEOR " SFM-TRIMRAIL i urunnccoury i io LR MOUNT DETAILS S10 SCALE'.NOTTO SCALE y— --� r MOUNTING LEGEND aoor.—. Noor aaresss o.u�Ew � eml x lrwcc MOUNT DETAIL-IPSFM u..rvo Nao a r.ru,K � WITM SIMPLEGR LSCO SGB�GRWNDINGL 5 ..... MOCULES IN PORTRA[i VNJDSPACE 0— v W. 'yo USPLCE n ytl„ IT vivint.Solar W� F�\ � _ len aw alas W l � BRUMBERG RESIDENCE las—FTsi . WPLWUITOH, 0.0108 PJ SYS TEM MOUNTING DETAIL S� TRIMRAIL 1 uiLin�cOUNrN ooesisao�o J MOUNT DETAILS S 1.0 SCALE'.NOTTOSCALE w.e _. PM1olovdtaio System Conduit Conductor Sc He RLL CO NBUCTVAS MUST BE COPPf AI M System Sia lWatls 0555 }a p asm peon A ConGunm/filar ..re r, 23/V FC SVs1em 51ze WaRs1 >YV IN Wee 10AWG wee 3lva�S. N/A-Free Al N/A Free 50 iota]Motluk Count ]9 IBare Co erGmun,41GUGECI 6RWG 1BAPE N/0.Free Ar oN3 E THWN-3 !BAWG 4PVq 2V IB/P EMT 3 THAN-L EGE/GEC BAWG IIGAN) EMT 3 THWNm3 BAWG 31LI IL21NI B/0/W fMT 3 THWN2 EGC/GEC BAWG IIGANI EMT 4TIWN-14 THWNd GEC BAWG IIGPNI EMT O lJ W C e� ? y � i 976 IU5 gR []211108 E1 Seuneo eoim on los I1gewPPM1 see ; n e0v/sos 0p6�e'olil xPa i wu va ntWmlSx xim s' ivmnaYwr a a p a om r IT.NN111. 1 ^ M = F3 FpP1Y5 .. SHEET wra.nMZFxs h we, e HFMF. mi I16 w/ommzsuMA —blee 3 M A ... ovne'sWalrel 3 0 nwe mPm SHEET HV MBE P: h vivint.Solar Residential Solar Power Purchase Agreement Customer Name&Contact Information: Installation Location: Name(s): Mark Brumberg Address: 139 FEDERAL ST NORTHAMPTON MA 01062-2703 Email: markbrumberg@comcast.net Approx.Installation Start and Completion Date: 2018-11-14 Primary Phone: 4133413943: Date of Customer Signature: ZO q IH-OS- Iq H Account No. 5888934 $O $0.168 1Oyr 2 . 9 % Up-Front Cost Energy Price($/kWh) Initial Term Escalator-Per Year Our Promises • We will design,Install,operate and maintain a solar energy system on your home(the"System"). • We warranty all of our work,and that our roof penetrations will be watertight,for 20 years. • We will fix or pay for any damage we may cause to your Property or belongings. • We will not place a lien on your Property,but will record a notice of our ownership of the System. • You will not be responsible for any personal property taxes assessed on the System. • The Energy Price includes a$5 monthly discount for paying by automatic debit from your bank account. • If you need to make Property repairs,we will remove and reinstall the System if you pay our estimated costs. At the End of Your Initial Term If You Move • You can renew the Agreement for a subsequent term; • You can transfer the Agreement to the new homeowner, • You can purchase the System;or regardless of credit rating; • You can request that we remove the System at no • You can prepay the Agreement; additional cost. • After the sixth anniversary,you can purchase the System;or • You can relocate the System under certain circumstances. Your Commitment • Pay us for all the power the System produces for 20 years. • Keep your roof in good condition throughout the Initial Term. • Respond to our sales and support teams when scheduling work and completing paperwork. • Maintain a broadband internet connection. • Continue service with your utility for any energy used beyond the System's production. You may cancel this Agreement any time prior to commencement of any work at or near your Property associated with installation of the System. Vivint Solar Developer, LLC (EIN: 80-0756438) is a licensed contractor in each state in which we operate, including Massachusetts,Contractor License Nos. HIC-170848 and ECA3141A. For more Information about our contractor licenses please visit www.v I,1msolar.cowlicenses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACTYOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN &OPT-OUT NOTICE BELOW IN SECTION 25 OF THE GENERAL PROVISIONS FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. The Notice of Cancellation may be sent to this address: help@vivintsolar.com I vivintsolar.com 1800 W Ashton Blvd., Lehi, UT 64043 Phone 877.404.41291 Fax 801.765.5758 ATTN: Processing Department Copyright©2018 Vivint Solar Developer,LLC. All Rights Reserved. PPA(3/2018,V4,0.1) 1 Page 1 of 16 SIGNATURE PAGE AND NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT. These documents are incorporated as part of this Agreement and apply to the relationship between you and us: (1) Residential Solar Power Purchase Agreement, (2) General Provisions, (3) Customer Packet; and (4) Change Orders, as applicable. B. WE HAVE NOTGUARANTEED,PROMISEDOR OTHERWISE REPRESENTED ANY REDUCTION IN ELECTRICITY COSTS IN RELATION TO THE SYSTEM THAT WILL BE INSTALLED ON YOUR PROPERTY. C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. D. IF YOU DO NOT ELECT ANY OF THE END-OF-TERM OPTIONS SET FORTH IN SECTION 2 OF THE PPA THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-TO-YEAR BASIS. CONSULT SECTION 2 OF THE PPA FOR MORE INFORMATION. E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TO A SALES REPRESENTATIVE. F. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by both you and us, before any work may be started. G. YOU, THE CUSTOMER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE TRANSACTION DATE OR,IF LATER,UNTILTHE START OF ANY WORK AT OR NEAR YOUR PROPERTY ASSOCIATED WITH INSTALLATION OF THE SYSTEM. SEE THE ATTACHED NOTICE OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. R&RCH RARNE: C r1 QKEOMMM: Richard U en LDna 202017 YmrteO Name: �ersonNa FmWNam<, Mark Brumberg Dot< 2018-05-18 Dof<: 2018-05-18 FOROFFKEUSEOWY TH6 AGREEMENr 6 NOT EfFEC NOR ENDING UFO W1W5M"DEWWPER,=UWILSIGNEDBYAN Spnofore AUEN00I2EDREVRMWAME. NMNFSOLUDEVELWMUC Noom Nom,. S,pnatare F W° Date 2018-05-18 F.mf<e Nome: Ruth Willardson Dote 2018-05-29 P. No 105361 -