Loading...
29-334 (3) 252 ACREBROOK DR BP-2016-1237 GIs#: COMMONWEALTH OF MASSACHUSETTS MO.Block:29-334 CITY OF NORTHAMPTON Lot,-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2018-1237 Project JS-2018-002208 Est Cost$12331 00 Fee: $75.110 PERMISSION IS HEREBY GRANTED TO. Const.Class: Contractor: License: Use Grout): VIVINT SOLAR DEVELOPER LLC 15688 Lot Size(sp.11): 10497.96 Owner: COLEMAN CHARLES L zoning: Applicant: VIVINT SOLAR DEVELOPER LLC AT: 252 ACREBROOK DR ApplicantAddress: Phone: Insurance: 150 PADGETTE ST UNIT B (413) 259-8044 O WC CHICOPEEMA01022 ISSUED ON:5/24/2018 0:00:00 TO PERFORM THE FOLLOWING WORILROOF MOUNTED PV SYSTEM - 19 PANELS @5.60 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy sienature: FeeTYpe: Date Paid: Amount: Building 5/242018 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner Department use only City of orthampton Status of Permit: �1AY 2 i12 Department Curb CuVDri Amin ility 12 ain Street Sewer/$eptic Availability. R om 100 WaterMell Availability n=T )FF,,, oiNg... P"" lllarl ton, MA 01060 Two Sets of Structural Plans - rNONP ION.MA01 40 Fax 413-567-1272 PloVSite Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 7 -SITE INFORMATION 8P- $ /a 3 1.1 Pro This section to be completed by eAe �( tr025�1 /tie Map Lq Lot �3 Unit f or4hau 4ofZ MA 0106 Zone Overlay District EIm SL DNWct CB DIMdet SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2. er of Record: rle.9 Coleman qU kjz2j k i6,r Name(Print) CYPeVrylppj -MCC Telephone /XO-(_,�-JIJ� Signature 2.2 Authorized ADent: Savina Cervone 150 Padgette St, Chicopee, MA 01022 Nam (Para) Curets Mailing Address'. 413-217-4033 9gnature T..phone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by pemiit anolicant 1. Building ..bf (a)Building Permit Fee 2. Electrical {/ S}/'1 (b)Estimated Total Cast of (�J Construction from 6 3. Plumbing Building Permit Fee �7 4. Mechanical(HVAC) / 5. Fire Protection 6. Total=(1 +2+3+4+5) Check Number This Section For Official Use Only Date Building Permit Number: Issued: Signatu : Building Co. sianerllnspector of Buildings Dale f Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To IncompWASAnf.mintIion, Existing Proposed Required by orting - Tb,s rolic n tobe filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: U R: Rear Building Height Bldg.Square Footage % Open Space Footage (Lot arra minus bids&paved kin #of Parking SpBces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O obtained O ,Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the conslmdion activity disturb(clearing, grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors ❑ Accessory Bldg. ❑ Demolition ❑ New Signs X01 Decks [O Siding[0] Other[[:I] Brief Description of Proposetl 4 W rlk Installation of roof mountedphotohotov Itaic sola st ps,(#ofmodules �(,(5 k W Aaeta iGo1`6r"e...ing [edr omn'�e'S No ding new bedroa r Qn� lQo Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 5a. If New house and or addition to existina housing, complete the followana: a. Use of building: One Family Two Family Other b. Number of rooms in each family und: Number of Bathrooms u Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stones? t Method of heating? Fireplaces or Woodsloves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 fl. of wetlands?_Yes No. Is construction within 100 yr. floodplain_Yes—No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes_No. I. Septic Tank_ City Sewer_ Private well_ City water Supply_ SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, , as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I, Vivint Solar Developer LLC as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Savina Cervone P' Name Signatureof OvmerlAgent Date , SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: John A Jalbert CS070940 License Number 150 Padeette St Unit B, Chicopee, MA 01022 03/25/2019 Ad ress Expiration Date � P/Lt 413-217-4033 azure Telephone 8,Registered Home In prey nt Contractor- Not Applicable ❑ VIVINT SOLAR DFVFI OPER. LLCIlohn A Jalhert 170848 Company Name Registration Number 1800 W Ashton Blvd. Leh' UT 84043 1/4/2020 Address Expiration Dale Telephone 413-2174033 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.182,§28C(8)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes...._. ❑ No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings ofone(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3 5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessary to such use and/or farm structures.A Person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building OfficiaL that he/she shall be responsible for all such work Performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion ofthe work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability ofEmployers to Employees for injuries not resulting in Death)ofthe Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work far you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the Stare Building Code,City of Northampton Ordinances,State and Local Zoning Laws and Stare of Massachusetts General Laws Annotated. Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined /by MGL c 111, S 150A. Address of the work: 4,rcbrCL"�K Lr The debris will be transported by: vivint solar Developer LLC The debris will be received by: vivint solar Developer LLC Building permit number: Name of Permit Applicant savina cewone 55� Date Signature of Permit Applicant ZN The Commonwealth of Massachusetts / Department of IndustrialAccidents OKIce oflnvestigations I Congress Street,Suite 100 Boston, MA 02114-2017 www.massgov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Leeibly Name(BusinessiorganizadoMndlviduap: Vivint Solar, Inc. Address: 1800 W Ashton Blvd. Cit /State/Lir Phone#: fifti-i7 1111 Are you an employer? Check the appropriate box: Type of project(required): L[O [am a employer with 253 4. ❑ I am a general contractor and 1 6. []New construction employees(full and/or part-time)." have hired the sub-contractors 2.❑ 1 am a sale proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These subcontractors have g, ❑ Demolition working for me in any capacity. employees and have workers9 []Building addition [No workers' comp. insurance comp.insura ine.t required.] euired. 5. ❑ We are a corporation and its 10,F] Electrical repairs or additions 3.❑ q ] officers have exercised their 11, Plumbing ns 1 am a homeowner doing all work ❑ rig reDairs or additions myself. [No workers' comp. right of exemption per MOL 12.❑Roof repairs insurance required.] t c. 152,§I(4),and we have no employers. [No workers' 13.aOdaergoiarinstallation._— camp.insurance required.] '.iny om ,.,it 111.1 chak.boa al most also fill our the section blow showing door workers'compmunwo policy infxuation, t ihsveowi an who submit this affidavit indicating that so doing all wok and that hire outside wmnears must submit a new.mda.it indicants,such. r(7mamn as that check this box most mnele:den additional shatshowing the none a it.subcmtncten and nate wheatcrmnot those rarities have "loymn. Vdsc sub-crntrecton have employees,they most ismonds their wakai comp.potiry rumba. lam an employer that is providing warken'mmpensaaon insurance for my employees. Below is the polity and job site information. Insurance Company Name: Zurich American Insurance Company Policy#or Self-ins. Lie�.^�#' WC509601302 _ . . Expiration Date::X111/121019 _ _. _fit Job Site Address:ay—*M ��f City/State/Zip Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure in secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250 00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DLA for insurance coverage verification. I do hereby certify ander t ins andpen perjury at the information provided above is true and correct. Signature: _ -- . - ._. __. Date Maine 801 477 1 Oficial use only. Do not write in this area,to be completedby city or town official. City or Town: Permit Lleense# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: ROYEI TYPE: COMI'MGYOR TWE: CSA 0_ _..4 011042020 VWIW SOLAR JOHN itW W.AM OM 04, V LSRI,UT &069 p ry vMauaehu DMpolmom N pW IC sah" bud Nluilurq IIpuI,YOAS uN MEMMp LkSnM: pd'IOMp C Wmcfion Supuvbor JOIW•.WMRi` . �,• ,, H"Tnx wL 4OUTR11MVTON Ml1 �. ��t'Olnc 'mice•- Eapiotbn: COTT4EIOfIM Owma*19 ACO CERTIFICATE OF LIABILITY INSURANCE DATEmWGD IDonzOa THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORWLTON ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER,THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, MEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURERS), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: N BIB DartlRcate holMr is an ADDRIONAL INSURED,the poliey(lea)must have ADDITIONAL INSURED provisions,or M endorsed. H SUBROGATON IS WAIVED,MAject to the tem.and conditions of the policy,certain Policies may mquim an andureamerd. A stamment on this caNRwte does not confer rights to the cerBRcats holder In(leu of such andamsem s). W D CEP R MARSII USA INC 122517TH COSTREETM SU.TE 13CC IM.Ha.fie, A m Dom. O dRODU 5VA ^.DI1AIIXLu: AIm.Dema.CenRceuen-manh.win Fax.2]2-9E01801 - - --- -- - rN6VRERl91.SfFORpXGGOVEMGE MNCI INGINCRA Axis SpHi llY fuoZe. IxmJF'-vvvnISNUr Inc INSURERS luW llAmtt adnl Su [e CUllEldny Ifi535 - Vv n15addr OLvelNprr LLC pau RBEEI A hent II ce C.mpenyI nOv1 IBMW Ast'Inn BW 1E2391 To, Ll B40E1 xsuRER G:Navlgalors msNrvrve Company NWRER E: COVERAGES CERTIFICATE NUMBER: SEA 00311419315 REVISION NUMBER: 5 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTNITH STANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.Imm 1 FOLCV Ef I POIlCY F11Y Wn TYPE OFNWRAxce PaucvxuxeER A % GgSNERCML6ENERKL1AB1131Y 3]16500(PEN ell$91]R1] II1101/2B1B OCCVRRENCE a 7063 70 EPGH t " 11 'YoO TO RENTcO I CLPIMAMP➢E X IOCCV0. (_PREM$ES(E nenpy_ 6 IOW,OW MW EXP Arn, ne nmmml_ S ROD) _ PERSONAL&AEV INJURY s 1pM EM 31N L AROREGATE Luall APPLIES PER: (GENE GGREGxxf E a)MOM X ! POL..Y JIj' LOC ROO CTS COYPOP AGO S 1000.003 .MER: R AuTOMMILELIMILn BAFW9601W1 ➢10112017 11,0112018 COMNNEINE MT s 10'10000 IE—a� L X UTO ..OILY J ( 1 NV OS ONLY qU 06UsfUI Pn eONLVI F S ED NON OWVEO RdPE OAaAGE y U O60NLY � X OS ONLY L�1 CmxyCal Dea s 260w0 X I UwR LM % OUR 1 177651 0112912011 11101121118 E.I.I.IVRRENGE S 5,00],000 X IXCEa9 LMB DEo aCAMALCYl5,11 I 1 RETENTIONI — IS C WCRIG'AIGp ..TI011 WG'RN6BIYL3(AOS) II0112018 IX SER UTE _ EN AxoeleLo.ERe LAMLW — g YIN WC50NO1403 MA) IIM1120ll 11rGOR e F 1,,00,000 oFFC WM UNNEW Ezc.AloEo+'cuT VE O NIa L.EAc cc ENT a __ IM„Jam,In11q 1 E L GREASE.EAFMItOYEE s TYJ00c0 'Il11''w JeecrlW un[er �EL.DISEASE.POLICY LIMIT 8 1 YJ0ODD OE ELRIPPON OFOPERAIIONSNIPv 0 1 EXCESS LIANIITY GAIIEXCBR8919IV 1➢,0112017 I11mESTIS EACH OCCURRENCE 4,000,0 AUTCIEL ONLY iAGGREGATE 15 NUN CExectio .6 GPERATONS I LCCA .I YES11GLE40GOR.Im.MNYrnY Ra.aS 'GA may ed N[xN 11 menepan.raWlM) CERTIFICATE HOLDER CANCELLATION T..Yn of Nnlhamimon SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 212 Main FIRM THIS EXPIRATION DATE THEREOF, NOTICE WILL BE DELNERED IN NonllanDar MA 01050 ACCORDANCE WITN THE PSI PROWSIONS. AUTRORnEDREPRERGRATNE Ke dlean M.Perste nl. 019 ACORD CORPORATION. All rights mwrved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD vivinte 800 W hshtoni. UT 840 3 Structural Group J.Malthew Walsh,SE, PE Jon P. Ward,SE, PE Senior Structural Engineering Manager Slru vwal Engineering Manager james.walsh@vivinlsolar.com jon.ward@dvivintsolar.com May 21, 2018 Re: Structural Engineering Services Coleman Residence 252 Acrebrook Dr, Northampton, MA S-5909566; MA-04 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information,we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence is typical wood framing construction with a maximum of two layers of composite shingle rooting. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir p2 or better with standard construction components and consists of the following: • Roof Sections (t and 2): Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to visually inspect the size and condition of the roof members. B. Loading Criteria 8.02 PSF= Dead Load(roofing/framing) 2.59 PSF= Dead Load(solar panels/mounting hardware) 10.61 PSF=Total Dead Load 20 PSF=Root Live Load 40 PSF=Ground Snow Load(based on local requirements) Wind speed of 117 mph (based on Exposure Category B-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent"Unirac, Inc. Installation Manual", which can be found on the Unirac, Inc. website (www.unirac.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1'h"thick and mounted 4'h" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. l Page 1 oil vivint. Page 2 of 2 3. Maximum allowable pullout per lag screw(5/16" x 411f) Is 235 lbs/inch of penetration as Identified In the National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir. Based on our evaluation, the pullout value, utilizing a penetration depth of 2'/2", is less than the maximum allowable per connection and therefore is adequate. 4. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10 and is specified below. The following values have been verified by in- house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections shall be staggered to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior d a Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal S acin in 72 72 72 48 L 48 48 Max U lift Load lbs 218 179 168 368 301 284— D.Summary Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly.This evaluation is in conformance with the 2015 International Residential Code with Massachusetts Amendments, current industry standards and practice,and the information supplied to us at the time of this report. If there are any questions regarding the above,or if more information is required, please contact me. AA4. OF Regards, NP Jon P.Ward,SE, PE AR MA License No. 52584 No sz P � �gFOIe TEREO 4. 9S/ONAL Pry 05/21/2018 vivint. e W STRING(5): OFS�U: � SYSTEM LEGEND WE9 ® x,PsuwuLEs wuuin nss PV SYSTEM SIZE'. MRLEFVI CGMP. NEW SfiWXW CC � ]&ILNN PC `t 1 252 ACREBROOK DR NORTHAMPTON,MA 01062 xG� 1GPE-]d u. N » o ,� EWE,N ...IF FEE. i FRONT C41bU5E. — SHWGLE ® MswMsysRugo6CtwECi. �UGRU O—__—__—__—__—__—__—__ M I FEE IRUN a�E' 1-1_�c' „I LES OR LE UN _ #NW„UNCRUN ,uWxTEoHEWMZ, ii J, j I ° I a o j 1 vivint.Solar 01 COLEMAN RESIDENCE J052 NE.FOON. ----------------------------------------------------- NOFSHONPlW.M9.01062 ETON WG s z SITE PLAN .H � - ' Pv1 .o1, E SCALE:71!'=1'-0' oww. wx � _- - -- - -- _- --�- MOUNTING LEGEND I { /.� SFM-TRIMRAIL WRH L� ,SFM-ROOF ATTACHMENT s SFM�TMMWL ' ROOFATTgCHMEM ° SFM-1" L C = `SFM-9"ATTACHED SPLICE .. I bF M.zu9"SPLICE / ^ sM ULES IN FOMAMILANDSPACF v.a zia ��,e ° SF�YOUT W� vnnnt.Solar 1B]]dW nYB COz�M_ aJ, i - uLSCO wen-.ONDI-wcs NFC`Z ONT NMMONR.M]s]O&ID9R M MOUNTING DTAIL 7 VEW 14CCOUNT1 0Ib M�UNT DETAILS � � S 1.0 Irhn SCALE:NOT TO SCALE _ _-__ \ w_N x PhPt9r01G10 5Y[fem 40hEWl LPniWcfur SehMNle AµCpNGI1L1ppSMUF1'pE[OPPEP iulalMMUIC Watts) 36p5 Iptl rGn nE�EGUGEC I.AGG ]Il A1—Alr rv/P IYCe1 M5µaem3lty Mol<rn�ttmytds fnneult iYpc LvnrMr is ACF SGm F.e;WUnt 38W IVV WIre J IDAWIi B�W.V-� WA-ll..Il N/A$Be Air ¢ E Coun[ 19 leare Wuce �_ - & JAA 21MYN.2 IA.GG 1ZL (VIl)1�t 8Ifl E� 3If" O m ITHWN3-EGC/GfC a AW I;lU EMT 3/i" "u 3 THWN�I lOAWtl 31LY]L3]X)tl/P/W EMi 3/<" c m Ga33& o Wwwz_Eg 6Et S awG IjGr�Ni EMT ata^ p a S iTHWWI 6AWG NMI 1L11ry tl/WW fMi A THWN-I-W pAWfl 1111.; Y.MT i� Vl �i d gm <illECW emnmla SrpyYSEe O ? T aPV/son wwrc00xxxxxn � m.Nt W3.ar ♦ /mn Wsa.nEM9�, w � rmnniws mmm.ior:v a � � 1 M _ .� —t'9240VPoo. SHEETIT " .X..H .ANu: ry mA ` W/0 nmZ OI OMr p SHEET NVM@PPR a nW(irWur r nfP�NxeiFuseoswn}R - - - -♦ -- ... __ _ _ stc v Owmmss M ryummstn sEMvlu ^t W PV FAodmlo Anne Is ITT Conductor Calculations g MOJ ule Make/M—t IinMO Solar 1gM195M WB Wlre gaW calculated humcate art.310 151811161 with amblenttemceresen calculatlans from s g a Maxg,,Poln[Cumn[ in pl 9,1 Ampz o It 31015(0)1311x1. r-Poin[Volta a Vm 33< Vols a MaOpP^{irc ui[VOltage lVod 39J Vol6 6r OnflmP[mtluc[ms wx us.no90'Ralumnamla citg lM relevant ambient temceralure e O yso Optimieer Solar EOge P330 SM1 vn-Gr[u it Cunent k[) 9,61 Ampz atlrynmentaM n<eway llllatllus[mentslmm 310.151011161. m F Ftt'Off XnN"[mtluctaz ere use the 35-C caurm ampanty.ar the Sal taunt.ammo.,wild, a Q i OC Input I.—,, 33O Wartf Max.San.Pa.10EP01 3o Amps the relewnt amblenl@mcemture aM raceway lilt antsu en Y.athcM1emrm less. y OC Maz.I,Its,Vol[age 0g VOl[s Num.Mar.POwer at IT lPm axl 195 Wat[z Th.reang I the twnduave a, nusVrents MU4 be g realerna,or local,m,the continuous DCMa¢Input Eunen[ ]3J5 Amps Max SVstem Vvlta a 1WJVOC IU VIEC) tluryupra led ou[pn mnenl. to pc CC Man.Outpw Current IS Amps Vo[ie mploralureCcefflnenl p19 %/C Calculatial Esample-Wire Bating(III a Ambient Teneeratwe PGANI x Canyon III Max.z[rin rau ngl heel tlepen0enl See SE d,—.nts. AE)—m---ciannuous Duty Output Cumnt .er Make/M.EeI ar Ftlge 5F3BWWus ACOututCwrent Ac[ortlln mart.6Al.g B11 1583 Amps (Oaeool'Tag$1DgaugeMremtectoHOA GOAx096z111Conduc'hors)=3B.4A>=IBJS CfC FBeienry 99 % FED iYM ULTIPLES 140 Van A ACO eraling Voltage 100 V.Its THIS PAN EL 15 FED BY MULTIPLE SOURE PlIb ANO 50 U0 IOXflm(iag 31'.]O gauge wire rz4tl(w 35 A. 35 A>-19.NA Cunt.Max.Out ut Current 16 4mpc ,Off Boo(Tag Al6gauge vnre ntetl bfi5/r, fiSAv 19]9A OC the .,Yl Cunent 10.5 Amps flmffvP mnEu[lor am pacifies designed In mmplianw with art. SM1vrt Circuit Cum.[ 35 Amps MANE Test.SID IIIg Q11a.310.151 B11311a.330.151 B11311U. ax.Output FaubCwren[ 25 V20 mz 310.131011"b"opler9Ta'lail ,g9. LEE.E.11petl8c ^ IemperaNm obtain fmm ASHeAE 30]tlala t,"s. ASHRAE 3012 Highest monthly l%DAE,Temp.:33]'C aS WwezI MIn Mean In reme O.B.: / M OCPO Calculations Drunk,s pled accord,to spenuolis tluaoutput curet PV ormunommal Cwrent hazed off werler mminuous output curve A IS of rt 69081A116 S ti 0p� ca nyerler 15E38NH-I IS Max Output—1111 A a 1251art 690 FLA11 j e 1979 A 120 A(n TPOI — system output current w/con,1-5 d,tv 19 79 a 30A 1Syztem OCPOI s i 71 t m OMer Notes F x •Designed acconing lo,aM IT CMB nla tions are Poo ltgrbe NEC 2011 SHEET •All lntetlar rz¢vap carrying OC mrnshl th ll he metallic NAME- as HEFT NUM BE H' N vivint.Solar Residential Solar Power Purchase Agreement Customer Name&Contact Information: Installation Location: Name(s): Charles Coleman Address: 252 ACREBROOK DR NORTHAMPTON MA 01062-3502 Email ciclmn3@comcast.net Approx.Installation Start and Completion Data 2018-11-08 Primary Phone: 4135860539 : Date of Customer Signature: 2018-05-12 Account No. 5909566 so 60.164 20yr 2 . 9 % Up-Front Cost Energy Price($/kWh) Initial Term Escalator-Per Year Our Promises • We will design,install,operate and maintain a solar energy system on your home(the"System'). • We warranty all of our work,and that our roof penetrations will be watertight,for 20 years. • We will fix or pay for any damage we may cause to your Property or belongings. • We will not place a lien on your Property,but will record a notice of our ownership of the System. • You will not be responsible for any personal property taxes assessed on the System. • The Energy Price includes a$5 monthly discount for paying by automatic debit from your bank account. • If you need to make Property repairs,we will remove and reinstall the System if you pay our estimated casts. At the End of Your Initial Term If You Move • You can renew the Agreement for a subsequent term; • You can transfer the Agreement to the new homeowner, • You can purchase the System;or regardless of credit rating; • You can request that we remove the System at no • You can prepay the Agreement; additional cost. • After the sixth anniversary,you can purchase the System;or • You can relocate the System under certain circumstances. Your Commitment • Pay us for all the power the System produces for 20 years. • Keep your roof in good condition throughout the Initial Term. • Respond to our sales and support teams when scheduling work and completing paperwork. • Maintain a broadband Internet connection. • Continue service with your utility for any energy used beyond the System's production. You may cancel this Agreement any time prior to commencement of any work at or near your Property associated with installation of the System. Vlvint Solar Developer. LLC(EIN: 80-0756438)is a licensed contractor in each state in which we operate.including Massachusetts,Contractor License Nos. HIC-170848 and ED 13141A. For more information about our contractor licenses please visit www.vivintsolareom/licenses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN & OPT-OUT NOTICE BELOW IN SECTION 25 OF THE GENERAL PROVISIONS FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. The Notice of Cancellation may be sent to this address: help@vivintsolaccom I vivintsolar.com 1800 W Ashton Blvd., Lehi, LIT 84043 Phone 877.404.4129 1 Fax 801.765.5758 ATTN: Processing Department Copyright©2018 Vivint Solar Developer, LLC. All Rights Reserved. PPA(3/2018,v4.0.1) I Page 1 of 16 SIGNATURE PAGE AND NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT. These documents are incorporated as part of this Agreement and apply to the relationship between you and us: (1) Residential Solar Power Purchase Agreement, (2) General Provisions, (3) Customer Packet; and (4) Change Orders, as applicable. B. WE HAVE NOTGUARANTEED,PROMISED OR OTHERWISE REPRESENTED ANY REDUCTION IN ELECTRICITYCOSTS IN RELATION TO THE SYSTEM THAT WILL BE INSTALLED ON YOUR PROPERTY. C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. D. IF YOU DO NOT ELECT ANY OF THE END-OF-TERM OPTIONS SET FORTH IN SECTION 2 OF THE PPA, THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-TO-YEAR BASIS. CONSULT SECTION 2 OF THE PPA FOR MORE INFORMATION. E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TO A SALES REPRESENTATIVE. F. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by both you and us, before any work may be started. G. YOU, THE CUSTOMER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAYAFTER THE TRANSACTION DATE OR,IF LATER,UNTILTHE STARTOF ANY WORKATOR NEAR YOUR PROPERTY ASSOCIATED WITH INSTALLATION OF THE SYSTEM. SEE THE ATTACHED NOTICE OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. ROPOUEM RATNE: V�"'AaY custowl" Sp�Nrt aveYates sgnohve I vnMed Nome: Charles Coleman 2018-05-12 D.02018-05-12 EOROFFICELMEOMY TNIS A(iIEEM 5 NDT EMC NOR 5114DM6 URONVN1WS DEVFUDRER,UCUMILWNEDRYAN Sgnarat AU IZEDRERRESENTAME. VNRRSDUIIDENEU]RR,LLC vmted Nan[ 2018-05-12 R.inrre Nomr Ruth Willardson �. 2018-05-15 voceavp no 105361