38A-104 (26) 74 VILLAGE HILL RD-#2N BP-2018-1161 GIS 9: COMMONWEALTH OF MASSACHUSETTS MamBlock: 38A- 104 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit. Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL 042A) Category, SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2018-1161 Proiect# JS-2018-002083 Est.Cost: $15939.00 Fee:$75.00 PERMISSION IS HEREBY GRANTED TO: Const Class: Contractor. License: Use Group: PIONEER VALLEY PHOTOVOLTAICS 111266 Lot Size(sq fl.): 24175.80 OwnerHOSPITAL HILL DEVELOPMENT LLC C/O MASSDEVELOPMENT LLC Zoning:PV(l00)/SG b(l00)/ Applicant: PIONEER VALLEY PHOTOVOLTAICS AT: 74 VILLAGE HILL RD - #2N Applicant Address: Phone: Insurance: 311 WELLS ST- SUITE B (413) 772-8788 Workers Compensation GREENFIELDMA01301 ISSUED ON.51712018 0:00.00 TO PERFORM THE FOLLOWING WORK ROOF MOUNTED SOLAR 8 MODULES 2.56KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of OccuoancY Signature: FeeTVpe: Date Paid: Amount: Building 5/7/2018 0:00:00 $75.00 212 Main Street, Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner Sola F ti- 9 City of Northampton 31e1>Np1ik ° u $uilding Department 212 Main Street MAY 4 2018 Room 100 No hampton, MA 01060 '1 4 - t e 13- 87-1240 Fax 413-587-1272 ` ,r , lot Y - q .`IOr:.MA01060 APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH AA ONE�JOR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION ,Pn7/ t < — //0 1.1 Property Address: This sectlon to be completed by office 74 Village Hill Road #2N, Northampton MA Map Lot Unit Zone Owr4y Dishlct Elm at District CB Distinct SECTION 2-PROPERTY OWNERSHIPIAUTHORIZED AGENT 2.1 Owner of Record: Nick and Janet Papouchis 334 North Mountain Ave Montclair NJ 07043 Name(Print) Cumanl Mailing Address (212) 807-0364 See attachment (A) Telephone Signature 2.2 Authorized Agent Pioneer Valley Photovoltaics Cooperative,LLC 311 Wells Street,Suite B,Greenfield,MA,01301 Name(Print) 46Current Mailing Address: 413-772-8788 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building $4,782 (a)Building Permit Fee 2. Electrical 11,157 (b)Estimated Total Cost of Construction M1nm 6 3. Plumbing Building Permit Fee 1/ 4. Mechanical(HVAC) 5.Fire Protection 6. Total=(1 +2+3+4+5) $15,939 1 Check Number 7 This Section For ONicial Use Only Building Permit Numbe Date Issued: Signatu Building mmissienerlinspecharof Buildings Dale oOU4 .1 q@ QG PVSquared 72-87 j 1Fax.vsquaredcoop 413-772-8668 Phone:413-771-8788/Far:413-771-8668 311 Welts St.,Ste.B/Greenfield,MA 01301 MA Elec.Lic.A13764 INA HIC 140077 Dear Town Inspections Officials, Please see our enclosed applications to permit a Solar Photovoltaic System in your jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp, employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our Greenfield, MA Headquarters since 2002. PV Squared is committed to complying with all Commonwealth laws and regulations. Our worksite guidelines are created with the intention of exceeding all safety, electrical, and building requirements as defined by their respective jurisdictional entities. This includes the work of people from multiple disciplines, including electrical engineering, structural engineering,civil engineering, electricians, construction supervisors, roofers,and their associated helpers. We are a company that values training and education.We make certain that every individual is qualified for the roles and responsibilities that they assume. It is our policy to pay for the employees travel and training time and cost of the education, including CSL and Journeyman and Master Electrician classes. As an electrical contractor we are furthermore guided by thejanuary 30,2009 Massachusetts Board of State Examiners of Electricians (BSEE)judgements, and rulings that have followed.We pay strict adherence to these mandates and all electrical work is conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also understand that non-electrical tasks associated with a Solar installation can be completed by non-electrical workers, such as CSLs and others. I have attached our installation policy for your review, as well as a list of example non-electrical tasks. Should you have any questions or concerns regarding this policy or delineation of work, please let us know. We are a learning organization that is always trying to improve on what we do. Respectfully, Adam Thurrell Operations Manager Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column m be filled in by Building Depamnent Lot Size Frontage Setbacks Front Side L:. R: L. R: Rear Building Height 1 Bldg.Square Footage Open Space Footage (Lot arca minus bldg&paved arkiv #of Parking Spaces votumc&Locative A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES O IF YES, date issued: '.. IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: I E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO O IF YES,then a Northampton Stone Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [[] Siding[[3] Other[EZO Brief Description of Proposed Work: �rmullation of rwf,mun�pAo4�voluia'fyNman wNem roaf In deMMarte farwtil]N Alteration of existing bedroom_Yes X No Adding new bedroom Yes X No Attached Narrative Renovating unfinished basement Yes x No Plans Attached Roll -Sheet ea.N New house and or addidon to existina housing-complete the following: a. Use of building ;One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stones? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain_Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank_ City Sewer Private well City water Supply SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Nick and Janet Papouchis as Owner of the subject property hereby authorize Philippe Rigollaud to act on my behalf,in all matters relative to work authorized by this building permit application. See attachment (A) 4 .20 .2018 Signature of Owner Date Philippe Rigollaud ,as BwA"Authonzed Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. PHILIPPE RIGOLLAUD Print No 4 .20 .2018 Signature of t Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Narver: Daniel Gomez Gonzalez CS-111266 License Number 43 Hatfield Street Northampton MA 01060 03/14/2021 Atltlress ,�,,,,I,.�-G Expiration Date ' vo 413-772-8788 Signature Telephone S.R gilstemd Nome ImpmwmsM Contractor: Not Applicable ❑ Pioneer Valley Photovoltaics Cooperative, LLC 140077 Company Name Registration Number 311 Wells Street Suite ElGreenfield MA 01301 09/15/2019 Address Expiration Date Telephone 413-772-8788 SECTION 10-WORKERS•COMPENSATION INSURANCE AFFIDAVIT(M.G.L.C.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this a�davil will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... El No...... ❑ 11, - Home Owner Exemption The current exemption for"homeowners"was extended to include Owneroccupled Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered u homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work Performed under the buildine permit. As acting Construction Supervisor yew presence on thejob site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you maybe tiable for person(s) you hire to perform work for you under this pemut. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature Attachment A AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT I hereby agree to the Project as set out above,and I agree to pay the contract price according to the Terms of Payment. I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement. 1 hereby authorize Pioneer Valley PhotoVobnbs Cooperative to proceed with the above-referenced Project In accordance with this Agreement.I further authorize Pioneer Valley PhotoVob lcs Cooperudve,or Its designated representative,to obtain required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project to be used by Pioneer Valley PhotoVokalcs Cooperative for marketing purposes.A check for the First Payment is enclosed and 1 am returning this Agreement within 21 days of the Proposal date. JAN z y tore Hy64M5 �MPau�ifiS & Printed Name Date 7 L S,9. re /� Title -J6t.1UT- Mir If Printed Name �— Date naWre U Title Proposalaw Agee era#00113452 Pape Id 13 N"PeP is-Jan.,25,2018 Commonwealth of Massachusetts e, Division of Professional Licensure Board of Building Regulations and Standards ConstrUCftn 'Saptilivisor CS-111266 Expires; 03M412021 DANIEL GOMEZ GONT.ALEZ 43 HATFIFi rf 8TREET NORTHAMPTON MA 01000 Commissioner Office of Consumer Affairs and Business Regulation One Ashburton Place - Suite 1301 Boston, Massachusetts 02108 Home Improvement Contractor Registration IYpe Corpow'Vn PIONEEH VALLEY I'HO I OVOL T AICs COOP RCExpiration. 9'1512 311 WELLS ST SUITE6 Expiration 09'752019 GREENFIELD.MA 01301 U,d.a Add,aas and Pelurn Card 01L[e o1 Consume AXaus a Bwmesf Pepulauon HOMF IMPROVEMENT CONTRACTOR Bepi51n4on valid N—dividuel use ony TYPE'.Lrvlxeneo' before the expiration dale if found retuiPto. QLBLS{IALMD rbQLrallpJ OHIce of Conaumel AHelm antl Busin�9(R¢gulabon IJW» W15?01C 10 Par'Plane,5u11e 5170 biONf.I H VN I E1 u,'W0V01AI(L C6U.' Boston.MA 02116 1+w 11-'rr1 H.GOI,AUD lo (Ifl l .l'-S SIJIIrC I Pin Mr. i°3o a loelsecletaq Not valid wl�t 5lgnature The Commonwealth ofMassachusetis Department of IndustrialAccidents I Congress Street,Suite 100 Boston,MA 02114-2017 www.massgov/dia WIV.rkers'Compensation Insurance Affidavit:Builders/Contractors/Elecrricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print L e bl Name(Business/0rganizatioNIndividua0:Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar Address:311 Wells Street,SuiteB City/State/Zip:Greenfield MA 01301 Phone#:413-772-8788 Are you an¢.pryer?Check rhe appmpriatc hos: Type of project(required): LCD I am a aopinyer with 4B employees(full and/or part-time),' 7. ❑New Construction 2.❑I am a sole pmpnctm or ownership and have no employees working for meth 8. ❑Remodeling any capacity.[No workers'comp,insurance raluired.] 3.E]I am a homeowner doing all work myself[No workers'campinsurance required.]t 9. ❑Demolition 4Q1 am a Immeownm and will be hiring contractors to conduct all wok on my property. I will 10❑Building addition cassam that all coomctms either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions pmpnetors wish an employees. 12.E]Plumbing repairs or additions 5.❑I aneageneralconmctha andInavehiredtheve wori ,cs'colistedon he mmchN sneer. 13.❑Roof repairs Thescsuboanmmors have employees anhave workers'wrap.insumnee 6.❑wearcaconforming and asofficershaveexercisedthetahighs su men,,quipar MGL c. 14.QOther Solar PV 152,$I(4),arM we nave rw employees.[No workers'comp.insman<e required.] 'Any applicant Nat checks box#1 most also fill out Ne swoon below showing their workers'compensation policy mf anon. 1 Bomcawoers who submit this affidavit indicating they are doing all work and dam hue outside comm". must submit a new affidavit indicating such, tConnsetms that check this Now must musicalan adinwhad s mat showing the game of the suh-c—mochas and state whether or not Nose entities lave employees. Iftbe subconmcmrs have employees,they must provide their worlaars'comp.policy number. 1 am an employer that is providing workers'compensadon insurance for my employees. Below is rhe policy and job site Informadon. Insurance Company Name:HDI Global Insurance Co/Energi Policy#or Self-ins.Lia#:EWGCR0002412118 Expiration Date:01/01/2019 Job Site Address:74 Village Hill Road#2N, City/State/Zip:Northampton MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of The DIA for insurance coverage verification. I do hereby certify under the pains andpenaldes ofperjury that the information provided above is true and correct Signature: D ate: 4.20.2018 Phone#: 413-772-8788 Official use only. Do not write in this area,to be completed by city or town officialf City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person Phone#: Acclsi CERTIFICATE OF LIABILITY INSURANCE 01/03'2018 THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTTUTE A CONTRACT BETWEEN THE ISSUING INSURERIS),AUTIIORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: Nthe certificate holder is an ADDITIONAL INSURED,tits policy(les)must have ADDITIONAL INSURED provisions or he endorsed. N SUBROGATION IS WAIVED,subject to Cie tonne and conditions Of Ne policy,certain policies may require an endorsement A statement on this cartiflcets does not confer rights to Me certi cate holder in lieu of such endonemenps). PRODUCER RAM,. Lima Powers Webber B Grinnell °NE 1.1 (413)561 A2 NOP (413)5856481 8 Norh King Street ADDREsi: yowersulwebberandgnrinell tom ININRERISIAFFORDING COVERAGE Ill Northampton MA 01060 INSORERA: HDI Global Ins.Goiilmi RSURED RSUREAe: Markelllmetio Pioneer Valley Ph01oV011a25 Coopera4ve,Inc. IFUR RERC Intern Ins.CO of Harm ver'EmI Arm Kim P omarn INSURER p'. 311 Wri SV¢eL SUile B IN SURER E' Greediest MA 01301 INSURER F: COVERAGES CERTIFICATE NUMBER Maher Fry 1-2019 REVISION NUMBER THIS IS TO CERTIFY THATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO TME INSURED NAMEDABOI¢FOR THE POLICY PERIOD INDICATED NOTWiTHSTANDINGANY REQUIREMENT TERM OR CONDITION OFANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR IAAY PERTAIN.THE INSURANCEAFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERNS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN LVFY HAVE BEEN REDUCED BY PAID CLAIMSINSIR CUL PARK Hou"c I., . ITS WPEOFIHSURANCE IN. .1 POLICY NUMBER cp n LM Mail CCMMERCIALGENEIULUABADY Eq CH OCCURRENCE E 1.000000 CONINUi E ®OCCUR PREMISES T.Avu—r S 100.000 ME°EXP AMY me omni 3 Excluded A EGGCR0002412118 0110V2018 011012019 PERSONALa AOVIN.IURY 1000 W GEN L AGGREGATE UNIT APPpES PER GENERAUGGREWTE a 2000.000 POLICY1:1ECT El LW PRODUCTS-COUPIOPAGG S 2.000000 OTHER AIJTpsORLE UARLRY E«e�aem Ino ulnT y 1000000 gNYgUTO BOnILYINJURYIFWveni I A oweEO 9CHEpuIEO EAGCRODO241218 01/o1p018 01101/2019 SO111IRLD YIPPac[aen) b .WTos OVLY AIITos HIRE, NONLOA Ad O ERtt°MI E S AUTOSONLY g 1d CDLY PonaS¢nl uneermsurec motorist BI L 20.ODO UMBRELLA WB OCCUR FACHOCCUrrl S 30DO 000 B ESCEss LMS CLUMSi IBEFXNE60457 0111 01/01/2019 WGREGATE s 3,000000 OEd I I RETENLON S E WORRERSCOMPENS k X Mr,TE I ERH ANDOWLOYIDUFUROUT)c A ANY PROPRIETORPARTNEWErEOUTrvE YIN EL EACHACCIOENT E 1000000 OPOCERIMEMBER EXOLU DED? ❑ NIA EWGCROD02412116 %/01/2018 01I01/2D19 teed DOD b,In Fill EL DISEASE EAEMPLOYEE b eros same,Anne: 1000000 pESCRI PTI ON OF OPERATIONS[Glow EL DISEASE POLICY LIHIT E Business Pers Proper, $1750 CDC C commercial Property CPR18ET7801 01/01/2018 01101/2019 InstaIMPOP 8350000 DESCRIPTION OF OKUMNS I L°CANOWS i VENICLES IACOAD 101,A40iBonal Rmuft"FiR ,moi M aNacM4emMiWceb oral CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE WE EXPIRATION DATE TIIEREOF,NOTICE WILL BE DELIVERED IN Evidence 01 Insurance ACCORDANCE WITH WE POLICY PROVISIONS. AUTHORIZED REPRESENTATNE 019983015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered Parke of ACORD 'm.... l ^ O Papouchis-Northampton i 701-" An Array for 74 Village Hill Rd,Apt 2 N Lm 'e 'gym S o` �p 6 O 0 E AmyLrcepp ,. GIS still doesn't have building on the map Picture of building(from previous install) PROJECT INFORMATION: *GUA, • Owner: Nick and Janet Papouchis • Address: 74 Village Hill Road#2N Northampton,MA 01060 +R '.ea . • Phone: (212)807-0364 IN squared Soar ]n aaeflk Sbnl5""a • Email: nickpapouchis@gmaii.com Ereendod,MA 01301 jgnelsoni@comcast.net dednaap uared.eoop mammae • System Size: 2.88 kW JOB: Papouchis • Modules: SunPower X22-360-D-AC -- • Rail: Ironridge XR100 Sin: 74 wlap Hill Road e314 • Bases: Ecofasten Quikfoot Northam%oo,MA D1 W • Snow Load: 40 lbs RENSIoNS: • Wind Speed: 117 mph Papouchis ROOF STRUCTURE: Array 27°Trusses @ 24"O.C. ROOF MATERIAL: Asphalt Shingles PROJECT NOTES: 1. Framing location to be verified on site. Existing Array Picard&Gindin 2. Slide rail assembly as needed to avoid interfering with splices or bases. Array 3. Unless otherwise noted bases are staggered and spaced at 48"O.C. �Lte Plan 4. Additional or alternative bases may be used �MgYaM ME: Site Plan to meet actual roof conditions. BILLOFMATERIALS FDMR: 1197S C/T PART MAKE MODEL BY: 1G DATE: 4/nrzole 24 Base Ecofasten Quikfoot SGLF. AS SRown 4 Rail Ironridge 17'XR100 BLK Sin: BYan• 24 Midclamp Ironridge XR100 UFO BLK 16 Endclamp Ironridge XR1000FOEnd Stopper ELK A-01 8 Module SunPower X22-360-D-AC ISheeH%y -,�------ 426"TO BE VERIFIED ON SITE eysrce 31,W ft 5. 8 ttO.KMA01301 desig@pvsM✓aeedca°e a�snzaJm Joe: Papouchis 1 V. WE: J9YiPade hl P°aPA}N `N N°rtNmp ONMA01060 I N – m I __. 1 21 .p II mc: Array Layout rpryq; t19)<i 1Y4" —1-- 82Y4" —A' Py; IG Space reserved Existing Picard&Gindin 1Y4" –�`-- 823/4" —,)` Papouchis DAM amrzo�e for future array, Arrays Array Array safe: +1s--r.o• SUE: Clamp Torque: 80 in-lbs L-Foot Torque: 250in4bs A-02 Max Span: 64" Max Cantilever: 21" Module Size: 61-5/16"x 41.3/16"x 1-13/16"(46mm) �s"L12 o12J Sunldower' X22-360-D-AC Residential AC Module Series Design-Driven Advantages #1 module aesthetics and efficiency' X Unmatched module reliability' - SERIES No electrolytic capacitors 25yearCombined Power and Product Warranty California Rule 21 Phase 1 compliant Maximize Value for Roof Size system for roof, not string Inverter Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems Optimize System and Installation Efficiency System expandability SunPower'AC modules,which include a factory integrated SnrPower Simplify& Speed Installation microinverter,provide revolutionary combination of high efficiency,high Factory integrated microinverter reliability,and module level DC-to-AC power conversion. Designed Robust,double-locking AC connectors Design flexibility offsite and probe specifically for use with SunPower lnvlsMoun(T"and the SunPower No DC string sizing process Mont oring System,SunPower AC modules enable rapid installation, best - Fewer installation steps than competing inclasssystem aesthetics,and intuitive visibility into-system performance. systems Intuitive commissioning All this comes with the bes:Combined Power and Produc Warranty in the industry- Component of Complete System Built for use with Sun Poweru'InvisiMouni and the SunPower Monitoring System(Pvssx) Grid Support Utility-interactive Smart Inverter Superior system reliability and aesthetics S.inPower's new Type DAC module is Ul tested and certified to UL 1741 SA and provides advanced smart inverter functions.SurPowerlypc D AC modules are fully compliant with the California Rule 21 Phase 1 requirernmes,and tho Rule 21 grid profile is easily set during commissioning with SunPower f'VSSx moni:oring hardware. sunpower.com SunlDower� X22-360-D-AC Residential AC Module Series IEFE1547a-2014' CA Rule 21` SRD Profile (default settings) min./nITJmax. mm./ om./max. Frequency(H7) _ 595/60.0/605 _ 585/600/605 Power Facto 0.99/1.00/100 0.85lead_/100/0.Klag . Reactive Power x169 Var Volt-VAI Voltage C240V 2112 240 1264 V C208 183/208/228,8V Max.Current @240V133A al V 134 A DC/A( CECCy,nve,sion Efficiency @240V 960% @208 V 95.5% Max Units l'er 2C A Branc-i Circuit @240V 12(single phase)) @208V 10(take per') v, Power 320 W 320 VA No active phase balancin for phase Installations SPR- 2-3WDAC Warranties 2S year limited powerwaranty Nom nal f c ver'(Pnom) 360 W _ 25real,limited product warranty Po e TOlerase /w 0% UL listed to UL 1741 SA 1 Avg Panel Eflicen_ry' 222% SRDS IEEL 1547-2003.IFFE 1547a201,FCA i Temp.kee!.(Power) -0.29%%C Rule 21 Phase 1 Three bypass diodes PV Rapid shutdown Equipment Shape Tolerance -Integated module level maxi rourr power point Equipment Grounding tracWng UL 6703.UL 9/03 Connecta s and cahl=s (load break disconnection) JL 1741 AC Module(Type 2 file rati^g) Operating Temp. -40 Fro+1WF)-40'Cto -89 C) Cemfirations Enables installation In accordance with. kid ax_Arnblent Temµ 122'F(50v NEC 6906 Max.Lead Wind 62 psf 3000 Pa 305 kg/m'front&back NEC 690.12 Rapid Shutdown(Inside and Sir 125 psf.6000 Pa,611 kg/m'fro^t ovaide'he array; Impact Resistance 11nch(25 mm)diameter hall at 52mph I23 Ms) NFC 690.15 AC Conneaors,69033aa) (E7(1) FCC and ICES 003 Class B When used with InvisiMount racking(J-2703) Sdav Celle 96 Monocrystal'ine Maxey,-Gen III Integrated grounding and bond ti II -tansn sbn tenperen glav tlanti- Fm IClos_ Class Afire rated I.,, llrc eg PID Test Potential-induced degetlaaon free o nen al Ratirg 0 [ oor drated - . Franc CISo,I dlackarydyd p'ighest AAMk, ring? amm OLOEIN Weight 45 x Ibsen 6 kg) I - _ Recorrr oed Ma g 13 ill (33 Module Starlitnm T 11 1 C-I rc, Ftr. i b 2014 Iti.ax0 roW yl �. Y [ I r l p21 tot1 .7 r ml 1- J I i - It '_ r ab 1Y 1x3lo IIIl rtl y1 a C P _ I I - II1 al ISI i eVi ._Lror d.e it - e ..((aurin I illi.na for]oiarL M�YM1M1y��lryf , ZAL IRONRIDGE XR100 Rail See Description / Length Rai Section Properties Property Value Total Cross-Sectional Area 0582 in' .66 Section Modulus(X-a)s( 0.297 in .46Moent of Inertia (X-a)(6) 0.390 in Moment - — Moment of Inertia (Y-ass( 0.08.5 in' Torsional Constant 0.214 in' Polar Moment of Inertia 0126 in" 1.99 APPROVED MATERIALS: 2.44 6005-T6,6005A-T61,6105-75,6N01-T6 234 I (34,000 PSI YIELD STRENGTH MINIMUM) I_ 58 -L ---�I - 1.25 Clear Pad Wick Pad Description/Length Material Weight Number Number XR-100-132A XR-100-137B %R100. Ratl 137'i l l Feeti 7.SO Ibs. %R-IOP168A %R-100-1688 XRI00, Rail 168" 14 Feet 6000-Series 9.55�s. XR-100-204A XR-100-201B %R100, Rai120F"Ill Feet) Ali11.601bs. v1.1 /llr IRONRIDGE XR100 Bonded Splice XR-100 RAIL 12.0 1 XR-100SPLC-BD KIT, XR100 BONDED SPLICE 2 1) Splice, XR100,Mill 12" long 2) Screw, SeN Drilling Isf 1.24 63 1.93 .31 T 0.42 S - 93 #12-14 TYPE-B'THREAD Property Value Properly Value Material 6000 Series Aluminum Material 300 Series Stainless Steel Finish Mill Finish Clear v1.0 F le ,, lq F OuikFOOt PRODUCT GUIDE Exploded Product View/B.O.M. - 1 Installation Instructions - 2 Cut Sheets - 3 r Specifications- 4 tr ,I 1 I 9 IY�ff o0a EcoFasten Solar® v QuikFoot— Product Guide Exploded Product View, Bill of Materials Materials Needed For Assembly 7 Item No. Description of Material/Part Quantity 1 QuikFoot Base Plate 1 6 2 Fastener(Length to be determined) 2 3 QuikFoot Flashing 1 5 4 EPDM Washer 1 5 L-102-3"Bracket"(other options available) 1 4 6 5/16"EPDM Bonded 18.8 SS Washer 1 7 3/8"Stainless Steel Hex Nut 1 3 Required Tools 2 1 f ,wFast6-394] Educm am Solar"M content protected antler 151 ighl.All 1Nod53,7 0 62 8181398 8214 1.1 EtnFaaMn Sder OrMucts are pmt¢d Hey 1pe(alloMng US.Parents 9.151.522 B26,15A]00828.181 J96828.166]13826,146,299 326,209,914026,24545492 6,2]2.1]40]822555]02 ' QuikFoot— Product Guide Cut Sheets: QF-AL-Base 2X 0 .33in �8.38mm] c E E N tf3 00 1 .50in 38.1Omm . 3J8"-16 Stud E v � QF-M : 1 .5' QF-L_ 1.75" ++ 877-859-3R47 ec0Fa5ten$oiaF'al corgeni protected under wpyrgh[.NI rights reservetl.10109/14 --- � 3 i� E.Fntan sdarprotluch eR pmwgC WMe tolb ng LL5.Paly Pals 522 B28,153700 B2 6.191 398 62 8.1N]13 B28,116 29152 8,20991482.299950 B28$12199628.225.651 B2 QuikFoot- Product Guide Cut Sheets: QFL-812 R.38in —�9.53mm 032in 10.81mm1 12.00in 304.80mm 3.00in 76.20mm' +ao� .50in 8.00in 12.70mmj 203.20mm 877-859-3947 EcoFaslen Solar'Pb content pmledetl urger copyright All rignis reservetl.10109114 33 EwFasfen 5darpmNctt are prolechN by Mefdlwlin9 U.5.Pahnis8t5t$2203B i53]OO B20 t¢1 X98028166]te B28 i<62698]8209,9t4 B2 H]OS C56 B20;iRs]2 B2H235S5]B2 QuikFoot- Product Guide Cut Sheets: Bracket Options-SCL-101-3 3/8' T - A 46 SERRATIONS Ali M I 1 7/8'' - RI/16' 1/4" 3/4" - 1/16" R.005 R.010 2X R.01 O 4 00 60. + 3/8,. .006.002 Q' 7/8'' X 820 ALIS A R'n"Fastan -859394] EcoFasten Solar,All wntenl protected under copyright.All rights refiervea.10109114 3] Sdar pmtluda are phaected by the Mluwing U,5,PaMnt 8151522 B28,153]00 828.181395 B28.166]13 B28,146299 B28.209914 B2&245 454 628.272174 828225 557 B2 ' QuikFoot- Product Guide Specifications PART 1 -GENERAL 1.1 SUMMARY 1.3 SUBMITTAL A. WORK INCLUDES - A. Submit manufacturer's written specifications. B. Base plate is 6000 series aluminum with one 1. QuikFoot base plate attachment bracket that B. Submit standard product cut sheets. PEM Type Press-In Stud 18.8 SS, attaches directly to the roof deck. C. Submit installation instructions. C. Fasteners to be compatible with chosen roof 2. Provide appropriate bracket and fasteners D. Submit product specific load test data,showing application and meet specified pull out values for the roof system. ultimate and allowable load values specific to as shown in load test data. B. RELATED SECTIONS the roof deck specified for the project. D. Counter Flashing is.032 gauge aluminum em- 1.Section D7600:Flashing and Sheet Metal bossed to accept shape of stainless steel base 2.Section D76Dd.Roofing 1.4 QUALITY ASSURANCE plate 3.Division 1:Administrative and Procedural Installer to be experienced in the installation of Requirements specified roofing material for no less than 5 years in 23 FINISH 4.Divisiori Thermal and Moisture Protection the area of the project. 1.2 SYSTEM DESCRIPTION A. Bracket is mill finish aluminum A. COMPONENTS: 1.5 DELIVERY/STORAGE/HANDLING B. Base flashing-Black-kynarpainted Inspect material upon delivery.Notify manufacturer L QuikFoot system consists of aluminum within 24 hours of an missing or defective items. bracket and base plate with(1)stainless steel y g PART 3 - EXECUTION m Keep material dry,covered,and off the ground until such,(1)stainless steel nut,(1)EPDM washer installed ancli bonded stainless steel and EPDM . 3.1 EXAMINATION washer. A. Substrate:Inspect structure on which brackets 2. Fasteners PART 2-PRODUCTS are to be installed and verify that it will with- A.To be of metal compatible with QuikFoot stand bracket 2.1 MANUFACTURER any additional loading that may be incurred. B.Fasteners should be selected for compat- EcoFasten Solar ibiliLy with the roof deck. 289 Harrel Street,Morrisoille,VT 05661 B. Notify General Contractor of any deficiencies C Fastener strength should exceed or be (877)859-3947 before installing EcoFasten Solar brackets. equal to that of the allowable load of the wwwecofastensolar.com system.See test data at C. Veri roofing material has been installed 2.2 MATERIALS correctlyec:tly prior to installing solar attachment www.ecofastensolar.com 3. Sealant(if required by roof manufacturer): A Attachment Bracket brackets. to be roof manufacturer approved. 6000 Series Aluminum(choose one) 3.2 INSTALLATION 4. Aluminum counter-Flashing t.CP-SQ-Slotted A. Comply with architectural drawings and project 5. Aluminum attachment bracket 2.F-111-A engineer's recommendations for location of 3.P-3-CSK system.Comply with Manufacturer's written in- B. DESIGN REQUIREMENTS: 4.SCL-101-3 stallation instructions for installation and layout. 1. Bracket spacing to be recommended by 5.L-102-3' project engineer. 6.L-102-6" 2. Install a minimum of two fasteners per 7.Z-101 base plate. 8.Comp Slide 3. It is important to design new structures or 8.Custom assess existing structures to make sure that they can withstand retained loads. EcoFaatSolarAl content protected under coprg2LAl rights resenedl. gh[s8ervtl. 14 47 EwmaeaSdarproyuctt am ProI,etl by hecalowng lSPahns 8151S22 328.153,]0 0828]61398B28,166 713 B26,146 299 82 8209 914 82 8.245 454 82 8,272 174 32 8225 55782 ' 3/8" — r A 46 SERRATIONS T T 1� RI /16" �-- 17/8" - 1/4' 1 3/4" — 6" rt R.005 R.010 V — 2X R.01 60.00° 3/8"+.006 + 1 .002 /8" .X = +/- .1 7/8' X 82° DETAIL A SCALE 3:1 .XX = +/- .01 .XXX= +/- .005 A 289 Harrel Street aODEcoFasten Solar Morrisville, vT 05661 SCL-101 -3 ® Toll Free Plane 1.877.859.3947 Toll Free Fax 1.888.768.9994 MATERIAL: Q, web www.ecofastensolar.wm 6000 SERIES ALUMINUM e-mail info@ewfastensolar.wm SCALE: 1:1 1/6/2012 SHEET 1 OF 1 Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT#9 Current version adopted by the Board of Directors on April 28, 2011 INSTALLATION CREW OPERATING POLICY This policy applies to all PV Squared employees in Massachusetts, but is particularly directed at those involved in the installation of solar electric and other renewable energy systems (licensed electrician, learner/apprentice electrician, licensed constructor supervisor, supervised carpenter and laborer). When engaged in this work as an employee of PV Squared on a PV Squared project site, activities of PV Squared employees are covered under the General Liability Insurance maintained by the Cooperative. It is the intent of this policy to provide clarity to installation situations where the applicable codes and regulations are unclear, ambiguous, or silent. It is possible that a municipal building or electrical inspector could interpret the codes and regulations in a manner that differs from what appears here. But this policy sets out, in writing, how the cooperative interprets legal work requirements and unclear details. It is an internal consensus working model, intended to be revised and improved from time to time. As a general matter, a city's or town's Building Commissioner is charged with enforcing the State Building Code, Plumbing and Gas Code, Electrical Code and Architectural Access Code. The commissioner addresses concerns about the safety, accessibility and security of construction of homes and businesses. The commissioner also enforces zoning bylaws. In accordance with Massachusetts General Law, employees of the cooperative who perform electrical tasks and activities must hold a Massachusetts journeymen's electrician license or be under the direct supervision of such licensed personnel. These tasks and activities include installing electrical wiring, conduits, apparatus, devices, fixtures or other appliances for carrying or using the electricity associated with Renewable Energy Generators (electrically active solar photovoltaic modules, wind turbine-generators, hydroelectric generators, etc.). In no circumstances shall the Massachusetts licensed journeymen have more than one learner or apprentice working with him/her or under his/her supervision. Mounting structures come in a variety of configurations and have differing functional and physical characteristics. A structural component or assembly becomes associated with electrical work as the Renewable Energy Generator is electrically bonded to the mounting structure. Unless otherwise noted in M.G.L. c.143 §§3 through §§60 inclusive, all structural work defined as follows shall not be required to be performed by a Massachusetts licensed journeymen electrician: • Structural improvements • Elements of a Renewable Energy Generator's support structure that fall under a building permit (e.g., assembly of top-of-pole mounting structure on steel pole with concrete foundation prior to execution of any required electrical bonding of the support structure and associated renewable energy generator (solar electric module) to the support structure Policy # 9 Installation Crew Operating Policy Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 • Roof-top mounting support structures including but not limited to posts, stand-offs, flashings, feet, and mounting rails • Operation of heavy equipment involved in moving, hoisting, digging and other tasks • Earth work, excavation and concrete work • Manual labor involved in moving loading and unloading of equipment • Moving, hoisting, and attaching an electrically bonded panel assembly (defined as one or more assembled and electrically bonded solar electric modules) to an existing structural support designed to host the panel assembly. Note however that construction of a panel assembly is an electrical task due to the required electrical bonding activities. Repair and Servicing of Installed Equipment Repair or replacement of an electrically bonded and/or energized renewable energy generator (e.g., installed solar electric panel) will be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician. Replacement of an installed inverter must be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician, if the work requires removal of AC and/or DC conduit and associated wiring that originates outside of the installed inverter (e.g., removal of external AC conduit and wiring between the inverter and point of interconnection with the on-site electrical service). Note that this activity may require a wiring permit in some local jurisdictions. This requirement also applies to the servicing of an installed inverter that involves replacement or repair of components and wiring internal to the pre-manufacturer inverter (i.e., factory installed components that were originally shipped with the inverter) even though such activity may not require a wiring permit. Replacement of an installed inverter may also be performed by a qualified technician who may or may not be a licensed electrician or properly supervised learner or apprentice working with a licensed electrician if the inverter is of a "plug and play" design. Such a qualified technician can also performed other tasks that include installation and servicing inverter-based performance monitoring systems (e.g., replacing internal communication cards, making "plug and play" ethernet connections, etc.), assuming these activities do not require creation of a new AC power source circuit to operate the communication system(s). Policy# 9 Installation Crew Operating Policy Non Electrical Work at a typical PV Squared Installation: • All Material Handling tasks o Module prep and moving o Ladder lift setup o Ladder set up o Trash/recycling removal and sorting • Structural Improvements o All carpentry work • Roof Mount Array o Fall protection anchor setup and removal o Layout and mounting bases o Racking up to but not including"bonding/grounding related activities" o Leveling of racking o Sealing seams/patching roofing/additional flashing • Ground mount array o Site work,earth moving o Trenching/digging o Construction of racking up to but not including "bonding/grounding related activities" • Conduit run o Making holes in structure o Fire blocking,sealing penetrations o Stickers • Power Board o Build wall, hang plywood o Stickers • Interconnection o Stickers • Monitoring o wife options o Any"plug and play'devices o Programming of monitoring devices o Computer based activities • Installation completion o Final building inspections o Install pictures-See checklist I Update one line and roof drawings to reflect as built o Completion checklist o Notes for others o COC left onsite • Misc o Truck Organizing o Material List,ordering o Daily check-in o Customer interaction and training activities