38A-104 (26) 74 VILLAGE HILL RD-#2N BP-2018-1161
GIS 9: COMMONWEALTH OF MASSACHUSETTS
MamBlock: 38A- 104 CITY OF NORTHAMPTON
Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit. Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL 042A)
Category, SOLAR ELECTRIC SYSTEM BUILDING PERMIT
Permit# BP-2018-1161
Proiect# JS-2018-002083
Est.Cost: $15939.00
Fee:$75.00 PERMISSION IS HEREBY GRANTED TO:
Const Class: Contractor. License:
Use Group: PIONEER VALLEY PHOTOVOLTAICS 111266
Lot Size(sq fl.): 24175.80 OwnerHOSPITAL HILL DEVELOPMENT LLC C/O MASSDEVELOPMENT LLC
Zoning:PV(l00)/SG b(l00)/ Applicant: PIONEER VALLEY PHOTOVOLTAICS
AT: 74 VILLAGE HILL RD - #2N
Applicant Address: Phone: Insurance:
311 WELLS ST- SUITE B (413) 772-8788 Workers
Compensation
GREENFIELDMA01301 ISSUED ON.51712018 0:00.00
TO PERFORM THE FOLLOWING WORK ROOF MOUNTED SOLAR 8 MODULES 2.56KW
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of OccuoancY Signature:
FeeTVpe: Date Paid: Amount:
Building 5/7/2018 0:00:00 $75.00
212 Main Street, Phone(413)587-1240,Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner
Sola
F ti- 9 City of Northampton 31e1>Np1ik ° u
$uilding Department
212 Main Street
MAY 4 2018 Room 100
No hampton, MA 01060 '1 4 - t e
13- 87-1240 Fax 413-587-1272 ` ,r ,
lot Y -
q .`IOr:.MA01060
APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH AA ONE�JOR TWO FAMILY DWELLING
SECTION 1 -SITE INFORMATION ,Pn7/ t < — //0
1.1 Property Address: This sectlon to be completed by office
74 Village Hill Road #2N, Northampton MA Map Lot Unit
Zone Owr4y Dishlct
Elm at District CB Distinct
SECTION 2-PROPERTY OWNERSHIPIAUTHORIZED AGENT
2.1 Owner of Record:
Nick and Janet Papouchis 334 North Mountain Ave Montclair NJ 07043
Name(Print) Cumanl Mailing Address (212) 807-0364
See attachment (A) Telephone
Signature
2.2 Authorized Agent
Pioneer Valley Photovoltaics Cooperative,LLC 311 Wells Street,Suite B,Greenfield,MA,01301
Name(Print) 46Current Mailing Address:
413-772-8788
Signature Telephone
SECTION 3-ESTIMATED CONSTRUCTION COSTS
Item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building $4,782 (a)Building Permit Fee
2. Electrical 11,157 (b)Estimated Total Cost of
Construction M1nm 6
3. Plumbing Building Permit Fee 1/
4. Mechanical(HVAC)
5.Fire Protection
6. Total=(1 +2+3+4+5) $15,939 1 Check Number 7
This Section For ONicial Use Only
Building Permit Numbe Date
Issued:
Signatu
Building mmissienerlinspecharof Buildings Dale
oOU4
.1 q@
QG PVSquared
72-87 j 1Fax.vsquaredcoop
413-772-8668
Phone:413-771-8788/Far:413-771-8668
311 Welts St.,Ste.B/Greenfield,MA 01301
MA Elec.Lic.A13764 INA HIC 140077
Dear Town Inspections Officials,
Please see our enclosed applications to permit a Solar Photovoltaic System in your
jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp,
employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our
Greenfield, MA Headquarters since 2002.
PV Squared is committed to complying with all Commonwealth laws and regulations. Our
worksite guidelines are created with the intention of exceeding all safety, electrical, and
building requirements as defined by their respective jurisdictional entities. This includes
the work of people from multiple disciplines, including electrical engineering, structural
engineering,civil engineering, electricians, construction supervisors, roofers,and their
associated helpers.
We are a company that values training and education.We make certain that every
individual is qualified for the roles and responsibilities that they assume. It is our policy to
pay for the employees travel and training time and cost of the education, including CSL and
Journeyman and Master Electrician classes.
As an electrical contractor we are furthermore guided by thejanuary 30,2009
Massachusetts Board of State Examiners of Electricians (BSEE)judgements, and rulings that
have followed.We pay strict adherence to these mandates and all electrical work is
conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also
understand that non-electrical tasks associated with a Solar installation can be completed
by non-electrical workers, such as CSLs and others. I have attached our installation policy
for your review, as well as a list of example non-electrical tasks.
Should you have any questions or concerns regarding this policy or delineation of work,
please let us know. We are a learning organization that is always trying to improve on what
we do.
Respectfully,
Adam Thurrell
Operations Manager
Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information
Existing Proposed Required by Zoning
This column m be filled in by
Building Depamnent
Lot Size
Frontage
Setbacks Front
Side L:. R: L. R:
Rear
Building Height 1
Bldg.Square Footage
Open Space Footage
(Lot arca minus bldg&paved
arkiv
#of Parking Spaces
votumc&Locative
A. Has a Special Permit/Variance/Finding ever been issued for/on the site?
NO O DONT KNOW O YES O
IF YES, date issued: '..
IF YES: Was the permit recorded at the Registry of Deeds?
NO O DONT KNOW O YES O
IF YES: enter Book Page and/or Document#
B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained O Obtained O , Date Issued:
C. Do any signs exist on the property? YES O NO O
IF YES, describe size, type and location:
D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O
IF YES, describe size, type and location: I
E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES NO O
IF YES,then a Northampton Stone Water Management Permit from the DPW is required.
SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable)
New House ❑ Addition ❑ Replacement Windows Alteration(s) Roofing ❑
Or Doors 0
Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [[] Siding[[3] Other[EZO
Brief Description of Proposed
Work: �rmullation of rwf,mun�pAo4�voluia'fyNman wNem roaf In deMMarte farwtil]N
Alteration of existing bedroom_Yes X No Adding new bedroom Yes X No
Attached Narrative Renovating unfinished basement Yes x No
Plans Attached Roll -Sheet
ea.N New house and or addidon to existina housing-complete the following:
a. Use of building ;One Family Two Family Other
b. Number of rooms in each family unit: Number of Bathrooms
c. Is there a garage attached?
d. Proposed Square footage of new construction. Dimensions
e. Number of stones?
f. Method of heating? Fireplaces or Woodstoves Number of each
g. Energy Conservation Compliance. Masscheck Energy Compliance form attached?
h. Type of construction
i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain_Yes No
j. Depth of basement or cellar floor below finished grade
k. Will building conform to the Building and Zoning regulations? Yes No.
I. Septic Tank_ City Sewer Private well City water Supply
SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I, Nick and Janet Papouchis as Owner of the subject
property
hereby authorize Philippe Rigollaud
to act on my behalf,in all matters relative to work authorized by this building permit application.
See attachment (A) 4 .20 .2018
Signature of Owner Date
Philippe Rigollaud ,as BwA"Authonzed
Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
PHILIPPE RIGOLLAUD
Print No
4 .20 .2018
Signature of t Date
SECTION 8-CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor: Not Applicable ❑
Name of License Narver: Daniel Gomez Gonzalez CS-111266
License Number
43 Hatfield Street Northampton MA 01060 03/14/2021
Atltlress ,�,,,,I,.�-G Expiration Date
' vo 413-772-8788
Signature Telephone
S.R gilstemd Nome ImpmwmsM Contractor: Not Applicable ❑
Pioneer Valley Photovoltaics Cooperative, LLC 140077
Company Name Registration Number
311 Wells Street Suite ElGreenfield MA 01301 09/15/2019
Address Expiration Date
Telephone 413-772-8788
SECTION 10-WORKERS•COMPENSATION INSURANCE AFFIDAVIT(M.G.L.C.152,§25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this a�davil will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes....... El No...... ❑
11, - Home Owner Exemption
The current exemption for"homeowners"was extended to include Owneroccupled Dwellings of one(1) or two(2)families
and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts
as supervisor.CMR 780, Sixth Edition Section 108.3.5.1.
Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there
is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm
structures.A person who constructs more than one home in a two-year period shall not be considered u homeowner.
Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be
responsible for all such work Performed under the buildine permit.
As acting Construction Supervisor yew presence on thejob site will be required from time to time,during and upon
completion of the work for which this permit is issued.
Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to
Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you maybe tiable for person(s)
you hire to perform work for you under this pemut.
The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of
Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated.
Homeowner Signature
Attachment A
AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT
I hereby agree to the Project as set out above,and I agree to pay the contract price according to the Terms of Payment.
I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement. 1 hereby
authorize Pioneer Valley PhotoVobnbs Cooperative to proceed with the above-referenced Project In accordance with
this Agreement.I further authorize Pioneer Valley PhotoVob lcs Cooperudve,or Its designated representative,to obtain
required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project to be
used by Pioneer Valley PhotoVokalcs Cooperative for marketing purposes.A check for the First Payment is enclosed
and 1 am returning this Agreement within 21 days of the Proposal date.
JAN z y tore
Hy64M5 �MPau�ifiS &
Printed Name Date
7 L
S,9. re /� Title
-J6t.1UT- Mir If
Printed Name �— Date
naWre U Title
Proposalaw Agee era#00113452 Pape Id 13
N"PeP is-Jan.,25,2018
Commonwealth of Massachusetts
e, Division of Professional Licensure
Board of Building Regulations and Standards
ConstrUCftn 'Saptilivisor
CS-111266 Expires; 03M412021
DANIEL GOMEZ GONT.ALEZ
43 HATFIFi rf 8TREET
NORTHAMPTON MA 01000
Commissioner
Office of Consumer Affairs and Business Regulation
One Ashburton Place - Suite 1301
Boston, Massachusetts 02108
Home Improvement Contractor Registration
IYpe Corpow'Vn
PIONEEH VALLEY I'HO I OVOL T AICs COOP RCExpiration. 9'1512
311 WELLS ST SUITE6 Expiration 09'752019
GREENFIELD.MA 01301
U,d.a Add,aas and Pelurn Card
01L[e o1 Consume AXaus a Bwmesf Pepulauon
HOMF IMPROVEMENT CONTRACTOR Bepi51n4on valid N—dividuel use ony
TYPE'.Lrvlxeneo' before the expiration dale if found retuiPto.
QLBLS{IALMD rbQLrallpJ OHIce of Conaumel AHelm antl Busin�9(R¢gulabon
IJW» W15?01C 10 Par'Plane,5u11e 5170
biONf.I H VN I E1 u,'W0V01AI(L C6U.' Boston.MA 02116
1+w 11-'rr1 H.GOI,AUD lo
(Ifl l .l'-S SIJIIrC
I Pin Mr. i°3o a loelsecletaq Not valid wl�t 5lgnature
The Commonwealth ofMassachusetis
Department of IndustrialAccidents
I Congress Street,Suite 100
Boston,MA 02114-2017
www.massgov/dia
WIV.rkers'Compensation Insurance Affidavit:Builders/Contractors/Elecrricians/Plumbers.
TO BE FILED WITH THE PERMITTING AUTHORITY.
Applicant Information Please Print L e bl
Name(Business/0rganizatioNIndividua0:Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar
Address:311 Wells Street,SuiteB
City/State/Zip:Greenfield MA 01301 Phone#:413-772-8788
Are you an¢.pryer?Check rhe appmpriatc hos: Type of project(required):
LCD I am a aopinyer with 4B employees(full and/or part-time),' 7. ❑New Construction
2.❑I am a sole pmpnctm or ownership and have no employees working for meth 8. ❑Remodeling
any capacity.[No workers'comp,insurance raluired.]
3.E]I am a homeowner doing all work myself[No workers'campinsurance required.]t 9. ❑Demolition
4Q1 am a Immeownm and will be hiring contractors to conduct all wok on my property. I will 10❑Building addition
cassam that all coomctms either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions
pmpnetors wish an employees.
12.E]Plumbing repairs or additions
5.❑I aneageneralconmctha andInavehiredtheve wori ,cs'colistedon he mmchN sneer. 13.❑Roof repairs
Thescsuboanmmors have employees anhave workers'wrap.insumnee
6.❑wearcaconforming and asofficershaveexercisedthetahighs
su men,,quipar MGL c.
14.QOther Solar PV
152,$I(4),arM we nave rw employees.[No workers'comp.insman<e required.]
'Any applicant Nat checks box#1 most also fill out Ne swoon below showing their workers'compensation policy mf anon.
1 Bomcawoers who submit this affidavit indicating they are doing all work and dam hue outside comm".
must submit a new affidavit indicating such,
tConnsetms that check this Now must musicalan adinwhad s mat showing the game of the suh-c—mochas and state whether or not Nose entities lave
employees. Iftbe subconmcmrs have employees,they must provide their worlaars'comp.policy number.
1 am an employer that is providing workers'compensadon insurance for my employees. Below is rhe policy and job site
Informadon.
Insurance Company Name:HDI Global Insurance Co/Energi
Policy#or Self-ins.Lia#:EWGCR0002412118 Expiration Date:01/01/2019
Job Site Address:74 Village Hill Road#2N, City/State/Zip:Northampton MA 01060
Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00
and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a
day against the violator.A copy of this statement may be forwarded to the Office of Investigations of The DIA for insurance
coverage verification.
I do hereby certify under the pains andpenaldes ofperjury that the information provided above is true and correct
Signature: D ate: 4.20.2018
Phone#:
413-772-8788
Official use only. Do not write in this area,to be completed by city or town officialf
City or Town: Permit/License#
Issuing Authority(circle one):
1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector
6.Other
Contact Person Phone#:
Acclsi CERTIFICATE OF LIABILITY INSURANCE
01/03'2018
THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTTUTE A CONTRACT BETWEEN THE ISSUING INSURERIS),AUTIIORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: Nthe certificate holder is an ADDITIONAL INSURED,tits policy(les)must have ADDITIONAL INSURED provisions or he endorsed.
N SUBROGATION IS WAIVED,subject to Cie tonne and conditions Of Ne policy,certain policies may require an endorsement A statement on
this cartiflcets does not confer rights to Me certi cate holder in lieu of such endonemenps).
PRODUCER RAM,. Lima Powers
Webber B Grinnell °NE 1.1 (413)561 A2 NOP (413)5856481
8 Norh King Street ADDREsi: yowersulwebberandgnrinell tom
ININRERISIAFFORDING COVERAGE Ill
Northampton MA 01060 INSORERA: HDI Global Ins.Goiilmi
RSURED RSUREAe: Markelllmetio
Pioneer Valley Ph01oV011a25 Coopera4ve,Inc. IFUR RERC Intern Ins.CO of Harm ver'EmI
Arm Kim P omarn INSURER p'.
311 Wri SV¢eL SUile B IN SURER E'
Greediest MA 01301 INSURER F:
COVERAGES CERTIFICATE NUMBER Maher Fry 1-2019 REVISION NUMBER
THIS IS TO CERTIFY THATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO TME INSURED NAMEDABOI¢FOR THE POLICY PERIOD
INDICATED NOTWiTHSTANDINGANY REQUIREMENT TERM OR CONDITION OFANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR IAAY PERTAIN.THE INSURANCEAFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERNS.
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN LVFY HAVE BEEN REDUCED BY PAID CLAIMSINSIR CUL PARK Hou"c I., .
ITS WPEOFIHSURANCE IN. .1 POLICY NUMBER cp n LM Mail
CCMMERCIALGENEIULUABADY Eq CH OCCURRENCE E 1.000000
CONINUi E ®OCCUR PREMISES T.Avu—r S 100.000
ME°EXP AMY me omni 3 Excluded
A EGGCR0002412118 0110V2018 011012019 PERSONALa AOVIN.IURY 1000 W
GEN L AGGREGATE UNIT APPpES PER GENERAUGGREWTE a 2000.000
POLICY1:1ECT El LW PRODUCTS-COUPIOPAGG S 2.000000
OTHER
AIJTpsORLE UARLRY E«e�aem Ino ulnT y 1000000
gNYgUTO BOnILYINJURYIFWveni I
A oweEO 9CHEpuIEO EAGCRODO241218 01/o1p018 01101/2019 SO111IRLD YIPPac[aen) b
.WTos OVLY AIITos
HIRE, NONLOA Ad O ERtt°MI E S
AUTOSONLY g 1d CDLY PonaS¢nl
uneermsurec motorist BI L 20.ODO
UMBRELLA WB OCCUR FACHOCCUrrl S 30DO 000
B ESCEss LMS CLUMSi IBEFXNE60457 0111 01/01/2019 WGREGATE s 3,000000
OEd I I RETENLON S E
WORRERSCOMPENS k X Mr,TE I ERH
ANDOWLOYIDUFUROUT)c
A ANY PROPRIETORPARTNEWErEOUTrvE YIN EL EACHACCIOENT E 1000000
OPOCERIMEMBER EXOLU DED? ❑ NIA EWGCROD02412116 %/01/2018 01I01/2D19 teed DOD
b,In Fill EL DISEASE EAEMPLOYEE b
eros same,Anne: 1000000
pESCRI PTI ON OF OPERATIONS[Glow EL DISEASE POLICY LIHIT E
Business Pers Proper, $1750 CDC
C commercial Property CPR18ET7801 01/01/2018 01101/2019 InstaIMPOP 8350000
DESCRIPTION OF OKUMNS I L°CANOWS i VENICLES IACOAD 101,A40iBonal Rmuft"FiR ,moi M aNacM4emMiWceb oral
CERTIFICATE HOLDER CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
WE EXPIRATION DATE TIIEREOF,NOTICE WILL BE DELIVERED IN
Evidence 01 Insurance ACCORDANCE WITH WE POLICY PROVISIONS.
AUTHORIZED REPRESENTATNE
019983015 ACORD CORPORATION. All rights reserved.
ACORD 25(2016103) The ACORD name and logo are registered Parke of ACORD
'm....
l ^ O
Papouchis-Northampton i 701-"
An Array for 74 Village Hill Rd,Apt 2 N
Lm
'e
'gym
S
o` �p
6
O
0
E
AmyLrcepp ,.
GIS still doesn't
have building
on the map
Picture of
building(from
previous install)
PROJECT INFORMATION: *GUA,
• Owner: Nick and Janet Papouchis
• Address: 74 Village Hill Road#2N
Northampton,MA 01060 +R
'.ea .
• Phone: (212)807-0364
IN squared Soar
]n aaeflk Sbnl5""a
• Email: nickpapouchis@gmaii.com Ereendod,MA 01301
jgnelsoni@comcast.net dednaap uared.eoop
mammae
• System Size: 2.88 kW
JOB: Papouchis
• Modules: SunPower X22-360-D-AC --
• Rail: Ironridge XR100 Sin: 74 wlap Hill Road e314
• Bases: Ecofasten Quikfoot Northam%oo,MA D1 W
• Snow Load: 40 lbs RENSIoNS:
• Wind Speed: 117 mph
Papouchis
ROOF STRUCTURE: Array
27°Trusses @ 24"O.C.
ROOF MATERIAL:
Asphalt Shingles
PROJECT NOTES:
1. Framing location to be verified on site. Existing Array Picard&Gindin
2. Slide rail assembly as needed to avoid
interfering with splices or bases. Array
3. Unless otherwise noted bases are staggered
and spaced at 48"O.C. �Lte Plan
4. Additional or alternative bases may be used �MgYaM ME: Site Plan
to meet actual roof conditions.
BILLOFMATERIALS FDMR: 1197S
C/T PART MAKE MODEL BY: 1G
DATE: 4/nrzole
24 Base Ecofasten Quikfoot
SGLF. AS SRown
4 Rail Ironridge 17'XR100 BLK Sin: BYan•
24 Midclamp Ironridge XR100 UFO BLK
16 Endclamp Ironridge XR1000FOEnd Stopper ELK A-01
8 Module SunPower X22-360-D-AC
ISheeH%y
-,�------ 426"TO BE VERIFIED ON SITE
eysrce
31,W ft 5. 8
ttO.KMA01301
desig@pvsM✓aeedca°e
a�snzaJm
Joe: Papouchis
1 V. WE: J9YiPade hl P°aPA}N
`N N°rtNmp ONMA01060
I
N
– m
I
__. 1 21 .p
II mc: Array Layout
rpryq; t19)<i
1Y4" —1-- 82Y4" —A' Py; IG
Space reserved Existing Picard&Gindin 1Y4" –�`-- 823/4" —,)` Papouchis DAM amrzo�e
for future array, Arrays Array Array safe: +1s--r.o•
SUE:
Clamp Torque: 80 in-lbs
L-Foot Torque: 250in4bs A-02
Max Span: 64"
Max Cantilever: 21"
Module Size: 61-5/16"x 41.3/16"x 1-13/16"(46mm) �s"L12 o12J
Sunldower' X22-360-D-AC Residential AC Module Series
Design-Driven Advantages
#1 module aesthetics and efficiency' X
Unmatched module reliability' - SERIES
No electrolytic capacitors
25yearCombined Power and Product
Warranty
California Rule 21 Phase 1 compliant
Maximize Value for Roof
Size system for roof, not string Inverter
Optimize performance of each module
Expand Deployment Options
Complex roofs and partial shading
Small systems Optimize System and Installation Efficiency
System expandability
SunPower'AC modules,which include a factory integrated SnrPower
Simplify& Speed Installation microinverter,provide revolutionary combination of high efficiency,high
Factory integrated microinverter
reliability,and module level DC-to-AC power conversion. Designed
Robust,double-locking AC connectors
Design flexibility offsite and probe specifically for use with SunPower lnvlsMoun(T"and the SunPower
No DC string sizing process Mont oring System,SunPower AC modules enable rapid installation, best
-
Fewer installation steps than competing inclasssystem aesthetics,and intuitive visibility into-system performance.
systems
Intuitive commissioning All this comes with the bes:Combined Power and Produc Warranty in
the industry-
Component of Complete System
Built for use with Sun Poweru'InvisiMouni
and the SunPower Monitoring System(Pvssx) Grid Support Utility-interactive Smart Inverter
Superior system reliability and aesthetics
S.inPower's new Type DAC module is Ul tested and certified to UL 1741
SA and provides advanced smart inverter functions.SurPowerlypc D AC
modules are fully compliant with the California Rule 21 Phase 1
requirernmes,and tho Rule 21 grid profile is easily set during
commissioning with SunPower f'VSSx moni:oring hardware.
sunpower.com
SunlDower� X22-360-D-AC Residential AC Module Series
IEFE1547a-2014' CA Rule 21`
SRD Profile (default settings)
min./nITJmax. mm./ om./max.
Frequency(H7) _ 595/60.0/605 _ 585/600/605
Power Facto 0.99/1.00/100 0.85lead_/100/0.Klag
.
Reactive Power x169 Var
Volt-VAI
Voltage C240V 2112 240 1264 V
C208 183/208/228,8V
Max.Current @240V133A
al V 134 A
DC/A( CECCy,nve,sion Efficiency @240V 960%
@208 V 95.5%
Max Units l'er 2C A Branc-i Circuit @240V 12(single phase))
@208V 10(take per') v,
Power 320 W 320 VA
No active phase balancin for phase Installations
SPR- 2-3WDAC Warranties 2S year limited powerwaranty
Nom nal f c ver'(Pnom) 360 W _ 25real,limited product warranty
Po e TOlerase /w 0% UL listed to UL 1741 SA
1
Avg Panel Eflicen_ry' 222% SRDS IEEL 1547-2003.IFFE 1547a201,FCA
i Temp.kee!.(Power) -0.29%%C Rule 21 Phase 1
Three bypass diodes PV Rapid shutdown Equipment
Shape Tolerance -Integated module level maxi rourr power point Equipment Grounding
tracWng UL 6703.UL 9/03 Connecta s and cahl=s
(load break disconnection)
JL 1741 AC Module(Type 2 file rati^g)
Operating Temp. -40 Fro+1WF)-40'Cto -89 C) Cemfirations Enables installation In accordance with.
kid ax_Arnblent Temµ 122'F(50v NEC 6906
Max.Lead Wind 62 psf 3000 Pa 305 kg/m'front&back NEC 690.12 Rapid Shutdown(Inside and
Sir 125 psf.6000 Pa,611 kg/m'fro^t ovaide'he array;
Impact Resistance 11nch(25 mm)diameter hall at 52mph I23 Ms) NFC 690.15 AC Conneaors,69033aa) (E7(1)
FCC and ICES 003 Class B
When used with InvisiMount racking(J-2703)
Sdav Celle 96 Monocrystal'ine Maxey,-Gen III Integrated grounding and bond ti
II -tansn sbn tenperen glav tlanti-
Fm IClos_ Class Afire rated
I.,,
llrc eg PID Test Potential-induced degetlaaon free
o nen al Ratirg 0 [ oor drated
-
. Franc CISo,I dlackarydyd p'ighest AAMk, ring? amm
OLOEIN
Weight 45 x Ibsen 6 kg) I - _
Recorrr oed Ma
g 13 ill (33
Module Starlitnm T
11 1 C-I rc, Ftr. i b 2014
Iti.ax0 roW yl
�. Y [ I r l p21 tot1 .7
r
ml 1- J I i -
It '_ r ab
1Y 1x3lo IIIl rtl y1 a
C P _
I I - II1 al ISI
i eVi ._Lror d.e it - e ..((aurin I illi.na for]oiarL M�YM1M1y��lryf
,
ZAL IRONRIDGE XR100 Rail
See Description / Length
Rai Section Properties
Property Value
Total Cross-Sectional Area 0582 in'
.66 Section Modulus(X-a)s( 0.297 in
.46Moent of Inertia (X-a)(6) 0.390 in
Moment
- — Moment of Inertia (Y-ass( 0.08.5 in'
Torsional Constant 0.214 in'
Polar Moment of Inertia 0126 in"
1.99 APPROVED MATERIALS:
2.44 6005-T6,6005A-T61,6105-75,6N01-T6
234 I (34,000 PSI YIELD STRENGTH MINIMUM)
I_
58
-L ---�I
- 1.25
Clear Pad Wick Pad Description/Length Material Weight
Number Number
XR-100-132A XR-100-137B %R100. Ratl 137'i l l Feeti 7.SO Ibs.
%R-IOP168A %R-100-1688 XRI00, Rail 168" 14 Feet 6000-Series 9.55�s.
XR-100-204A XR-100-201B %R100, Rai120F"Ill Feet) Ali11.601bs.
v1.1
/llr IRONRIDGE XR100 Bonded Splice
XR-100 RAIL
12.0
1
XR-100SPLC-BD
KIT, XR100 BONDED SPLICE
2
1) Splice, XR100,Mill 12" long 2) Screw, SeN Drilling
Isf
1.24
63
1.93 .31
T
0.42 S -
93
#12-14 TYPE-B'THREAD
Property Value Properly Value
Material 6000 Series Aluminum Material 300 Series Stainless Steel
Finish Mill Finish Clear
v1.0
F
le ,, lq F
OuikFOOt PRODUCT GUIDE
Exploded Product View/B.O.M. - 1
Installation Instructions - 2
Cut Sheets - 3
r
Specifications- 4
tr
,I 1
I 9 IY�ff
o0a EcoFasten Solar®
v
QuikFoot— Product Guide Exploded Product View, Bill of Materials
Materials Needed For Assembly
7 Item No. Description of Material/Part Quantity
1 QuikFoot Base Plate 1
6 2 Fastener(Length to be determined) 2
3 QuikFoot Flashing 1
5 4 EPDM Washer 1
5 L-102-3"Bracket"(other options available) 1
4 6 5/16"EPDM Bonded 18.8 SS Washer 1
7 3/8"Stainless Steel Hex Nut 1
3
Required Tools
2
1
f
,wFast6-394] Educm am
Solar"M content protected antler 151 ighl.All 1Nod53,7 0 62 8181398 8214 1.1
EtnFaaMn Sder OrMucts are pmt¢d Hey 1pe(alloMng US.Parents 9.151.522 B26,15A]00828.181 J96828.166]13826,146,299 326,209,914026,24545492 6,2]2.1]40]822555]02 '
QuikFoot— Product Guide Cut Sheets: QF-AL-Base
2X 0 .33in
�8.38mm]
c E E
N
tf3 00
1 .50in
38.1Omm .
3J8"-16 Stud
E
v �
QF-M : 1 .5'
QF-L_ 1.75" ++
877-859-3R47 ec0Fa5ten$oiaF'al corgeni protected under wpyrgh[.NI rights reservetl.10109/14 --- � 3 i�
E.Fntan sdarprotluch eR pmwgC WMe tolb ng LL5.Paly Pals 522 B28,153700 B2 6.191 398 62 8.1N]13 B28,116 29152 8,20991482.299950 B28$12199628.225.651 B2
QuikFoot- Product Guide Cut Sheets: QFL-812
R.38in
—�9.53mm 032in
10.81mm1
12.00in
304.80mm
3.00in
76.20mm'
+ao�
.50in
8.00in
12.70mmj
203.20mm
877-859-3947 EcoFaslen Solar'Pb content pmledetl urger copyright All rignis reservetl.10109114 33
EwFasfen 5darpmNctt are prolechN by Mefdlwlin9 U.5.Pahnis8t5t$2203B i53]OO B20 t¢1 X98028166]te B28 i<62698]8209,9t4 B2 H]OS C56 B20;iRs]2 B2H235S5]B2
QuikFoot- Product Guide Cut Sheets: Bracket Options-SCL-101-3
3/8'
T -
A
46 SERRATIONS Ali
M
I
1 7/8'' - RI/16'
1/4"
3/4" - 1/16"
R.005
R.010
2X R.01
O 4 00
60.
+
3/8,. .006.002
Q' 7/8'' X 820 ALIS A
R'n"Fastan
-859394] EcoFasten Solar,All wntenl protected under copyright.All rights refiervea.10109114 3]
Sdar pmtluda are phaected by the Mluwing U,5,PaMnt 8151522 B28,153]00 828.181395 B28.166]13 B28,146299 B28.209914 B2&245 454 628.272174 828225 557 B2
' QuikFoot- Product Guide Specifications
PART 1 -GENERAL
1.1 SUMMARY 1.3 SUBMITTAL
A. WORK INCLUDES - A. Submit manufacturer's written specifications. B. Base plate is 6000 series aluminum with one
1. QuikFoot base plate attachment bracket that B. Submit standard product cut sheets. PEM Type Press-In Stud 18.8 SS,
attaches directly to the roof deck. C. Submit installation instructions. C. Fasteners to be compatible with chosen roof
2. Provide appropriate bracket and fasteners D. Submit product specific load test data,showing application and meet specified pull out values
for the roof system.
ultimate and allowable load values specific to as shown in load test data.
B. RELATED SECTIONS the roof deck specified for the project. D. Counter Flashing is.032 gauge aluminum em-
1.Section D7600:Flashing and Sheet Metal bossed to accept shape of stainless steel base
2.Section D76Dd.Roofing 1.4 QUALITY ASSURANCE plate
3.Division 1:Administrative and Procedural Installer to be experienced in the installation of
Requirements specified roofing material for no less than 5 years in 23 FINISH
4.Divisiori Thermal and Moisture Protection the area of the project.
1.2 SYSTEM DESCRIPTION A. Bracket is mill finish aluminum
A. COMPONENTS: 1.5 DELIVERY/STORAGE/HANDLING B. Base flashing-Black-kynarpainted
Inspect material upon delivery.Notify manufacturer
L QuikFoot system consists of aluminum within 24 hours of an missing or defective items.
bracket and base plate with(1)stainless steel y g PART 3 - EXECUTION
m
Keep material dry,covered,and off the ground until
such,(1)stainless steel nut,(1)EPDM washer
installed
ancli bonded stainless steel and EPDM . 3.1 EXAMINATION
washer. A. Substrate:Inspect structure on which brackets
2. Fasteners PART 2-PRODUCTS are to be installed and verify that it will with-
A.To be of metal compatible with QuikFoot stand
bracket 2.1 MANUFACTURER any additional loading that may be incurred.
B.Fasteners should be selected for compat- EcoFasten Solar
ibiliLy with the roof deck. 289 Harrel Street,Morrisoille,VT 05661 B. Notify General Contractor of any deficiencies
C Fastener strength should exceed or be (877)859-3947 before installing EcoFasten Solar brackets.
equal to that of the allowable load of the wwwecofastensolar.com
system.See test data at C. Veri roofing material has been installed
2.2 MATERIALS correctlyec:tly prior to installing solar attachment
www.ecofastensolar.com
3. Sealant(if required by roof manufacturer): A Attachment Bracket brackets.
to be roof manufacturer approved. 6000 Series Aluminum(choose one)
3.2 INSTALLATION
4. Aluminum counter-Flashing t.CP-SQ-Slotted A. Comply with architectural drawings and project
5. Aluminum attachment bracket 2.F-111-A engineer's recommendations for location of
3.P-3-CSK system.Comply with Manufacturer's written in-
B. DESIGN REQUIREMENTS: 4.SCL-101-3 stallation instructions for installation and layout.
1. Bracket spacing to be recommended by 5.L-102-3'
project engineer. 6.L-102-6"
2. Install a minimum of two fasteners per 7.Z-101
base plate. 8.Comp Slide
3. It is important to design new structures or 8.Custom
assess existing structures to make sure that
they can withstand retained loads.
EcoFaatSolarAl content protected under coprg2LAl rights resenedl.
gh[s8ervtl. 14 47
EwmaeaSdarproyuctt am ProI,etl by hecalowng lSPahns 8151S22 328.153,]0
0828]61398B28,166
713 B26,146 299 82 8209 914 82 8.245 454 82 8,272 174 32 8225 55782 '
3/8" —
r
A
46 SERRATIONS
T T
1�
RI /16"
�-- 17/8" -
1/4'
1 3/4" — 6"
rt
R.005
R.010
V — 2X R.01
60.00°
3/8"+.006 + 1
.002 /8"
.X = +/- .1 7/8' X 82° DETAIL A
SCALE 3:1
.XX = +/- .01
.XXX= +/- .005
A 289 Harrel Street
aODEcoFasten Solar Morrisville, vT 05661 SCL-101 -3
® Toll Free Plane 1.877.859.3947
Toll Free Fax 1.888.768.9994 MATERIAL:
Q, web www.ecofastensolar.wm 6000 SERIES ALUMINUM
e-mail info@ewfastensolar.wm SCALE: 1:1 1/6/2012 SHEET 1 OF 1
Pioneer Valley PhotoVoltaics Cooperative
POLICY DOCUMENT#9
Current version adopted by the Board of Directors on April 28, 2011
INSTALLATION CREW OPERATING POLICY
This policy applies to all PV Squared employees in Massachusetts, but is particularly
directed at those involved in the installation of solar electric and other renewable energy
systems (licensed electrician, learner/apprentice electrician, licensed constructor
supervisor, supervised carpenter and laborer).
When engaged in this work as an employee of PV Squared on a PV Squared project site,
activities of PV Squared employees are covered under the General Liability Insurance
maintained by the Cooperative.
It is the intent of this policy to provide clarity to installation situations where the
applicable codes and regulations are unclear, ambiguous, or silent. It is possible that a
municipal building or electrical inspector could interpret the codes and regulations in a
manner that differs from what appears here. But this policy sets out, in writing, how the
cooperative interprets legal work requirements and unclear details. It is an internal
consensus working model, intended to be revised and improved from time to time.
As a general matter, a city's or town's Building Commissioner is charged with enforcing the
State Building Code, Plumbing and Gas Code, Electrical Code and Architectural Access
Code. The commissioner addresses concerns about the safety, accessibility and security of
construction of homes and businesses. The commissioner also enforces zoning bylaws.
In accordance with Massachusetts General Law, employees of the cooperative who perform
electrical tasks and activities must hold a Massachusetts journeymen's electrician license
or be under the direct supervision of such licensed personnel. These tasks and activities
include installing electrical wiring, conduits, apparatus, devices, fixtures or other
appliances for carrying or using the electricity associated with Renewable Energy
Generators (electrically active solar photovoltaic modules, wind turbine-generators,
hydroelectric generators, etc.).
In no circumstances shall the Massachusetts licensed journeymen have more than one
learner or apprentice working with him/her or under his/her supervision.
Mounting structures come in a variety of configurations and have differing functional and
physical characteristics. A structural component or assembly becomes associated with
electrical work as the Renewable Energy Generator is electrically bonded to the
mounting structure.
Unless otherwise noted in M.G.L. c.143 §§3 through §§60 inclusive, all structural work
defined as follows shall not be required to be performed by a Massachusetts licensed
journeymen electrician:
• Structural improvements
• Elements of a Renewable Energy Generator's support structure that fall under a
building permit (e.g., assembly of top-of-pole mounting structure on steel pole
with concrete foundation prior to execution of any required electrical bonding of
the support structure and associated renewable energy generator (solar electric
module) to the support structure
Policy # 9
Installation Crew Operating Policy
Pioneer Valley PhotoVoltaics Cooperative
POLICY DOCUMENT #9
Current version adopted by the Board of Directors on April 28, 2011
• Roof-top mounting support structures including but not limited to posts, stand-offs,
flashings, feet, and mounting rails
• Operation of heavy equipment involved in moving, hoisting, digging and other tasks
• Earth work, excavation and concrete work
• Manual labor involved in moving loading and unloading of equipment
• Moving, hoisting, and attaching an electrically bonded panel assembly (defined as
one or more assembled and electrically bonded solar electric modules) to an
existing structural support designed to host the panel assembly. Note however that
construction of a panel assembly is an electrical task due to the required electrical
bonding activities.
Repair and Servicing of Installed Equipment
Repair or replacement of an electrically bonded and/or energized renewable energy
generator (e.g., installed solar electric panel) will be performed by a licensed electrician
or properly supervised learner or apprentice working with the licensed electrician.
Replacement of an installed inverter must be performed by a licensed electrician or
properly supervised learner or apprentice working with the licensed electrician, if the work
requires removal of AC and/or DC conduit and associated wiring that originates outside of
the installed inverter (e.g., removal of external AC conduit and wiring between the
inverter and point of interconnection with the on-site electrical service). Note that this
activity may require a wiring permit in some local jurisdictions. This requirement also
applies to the servicing of an installed inverter that involves replacement or repair of
components and wiring internal to the pre-manufacturer inverter (i.e., factory installed
components that were originally shipped with the inverter) even though such activity may
not require a wiring permit.
Replacement of an installed inverter may also be performed by a qualified technician who
may or may not be a licensed electrician or properly supervised learner or apprentice
working with a licensed electrician if the inverter is of a "plug and play" design. Such a
qualified technician can also performed other tasks that include installation and servicing
inverter-based performance monitoring systems (e.g., replacing internal communication
cards, making "plug and play" ethernet connections, etc.), assuming these activities do not
require creation of a new AC power source circuit to operate the communication system(s).
Policy# 9
Installation Crew Operating Policy
Non Electrical Work at a typical PV Squared Installation:
• All Material Handling tasks
o Module prep and moving
o Ladder lift setup
o Ladder set up
o Trash/recycling removal and sorting
• Structural Improvements
o All carpentry work
• Roof Mount Array
o Fall protection anchor setup and removal
o Layout and mounting bases
o Racking up to but not including"bonding/grounding related activities"
o Leveling of racking
o Sealing seams/patching roofing/additional flashing
• Ground mount array
o Site work,earth moving
o Trenching/digging
o Construction of racking up to but not including "bonding/grounding related
activities"
• Conduit run
o Making holes in structure
o Fire blocking,sealing penetrations
o Stickers
• Power Board
o Build wall, hang plywood
o Stickers
• Interconnection
o Stickers
• Monitoring
o wife options
o Any"plug and play'devices
o Programming of monitoring devices
o Computer based activities
• Installation completion
o Final building inspections
o Install pictures-See checklist
I Update one line and roof drawings to reflect as built
o Completion checklist
o Notes for others
o COC left onsite
• Misc
o Truck Organizing
o Material List,ordering
o Daily check-in
o Customer interaction and training activities