17C-041 (16) 63 SHEFFIELD LN BP-2018-1015 GIS#: COMMONWEALTH OF MASSACHUSETTS Mao:Block: 17C-041 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGLLcc.1144/2�A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2018-1015 Project# JS-2018-001843 Est. Cost: $25580.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: VALLEY SOLAR LLC 110400 Lot Size(sa. h.): 15725.16 Owner: CHODOS LEIGH zoning: URBt100yURA(0)/ Applicant. VALLEY SOLAR LLC AT: 63 SHEFFIELD LN Applicant Address: Phone: Insurance: PO BOX 60627 (413) 584-8844 WC FLORENCEMA01062 ISSUED ON.41612018 0:00:00 TO PERFORM THE FOLLOWING WORK22 PANEL ROOF MOUNTED SOLAR ARRAY - 7.15KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House p Foundation: Driveway Final: Final Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeTvoe: Date Paid: Amount: Building 4/6/2018 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (4 13)587-1272 Louis Hasbrouck—Building Commissioner ' So (a,r Department use only 4�pl y? �6 City Tipton Status of Permit ) epartment Curb Cut/Driveway Permit l t , ��s�o 2 Main Street SewenSeptic Availability y1_�1. �.¢�ov� Room 100 WaterrWell Availability Northampton, MA 01060 Two Sets of Structural Plans _ one 413-587-1240 Fax 413-587-1272 PIoUSite Plans Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION aP— 15— la15 1.1 Property Adcdrress. This section to be completed by office r63 JIr.�efpeLD L4NC ( 7 Map 6 Lot Unit FLov—Fvwym,q 0106a- Zone Overlay District Elm SL Disbict CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record L H c C S 63 olo63 Name(Pool) Current Mallinq Atldress 611T 0 8181 Telephone Signature 2.2 Authorized Agent: Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Print) Current Mailing Address. 413-584-8844 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee ��... 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+ 5) �, Check Number This Section For Official Use Only Building Permit Number'. Date Issued: Signature'. Building Co sionerllospector of Buildings Date info�a valleysolar.solar I EMAIL ADDRESS REQUIRED; CON ACTO $PCCiOn 4. ZONING AR Information Must Be ConiPermit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning ibis column m be fitI d to by Building llepanment Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg.Square Footage Open Space Footage % (Lot area minus bldg x:ps,ed rkiv ) A ol-Parking Spaces Fill: columc X Loc,ir.) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW 0 YES O IF YES: enter Book Page and/or Document k B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be Dbtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or addil ions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E, Will the construction activity disturb(Gearing, grading, excavation, or filling)over t acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION$-DESCRIPTION OF PROPOSED WORK tcheck all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors D Accessory Bldg. ❑ Demolition ❑ New Signs [[I] //L Decks [p Sidling(CI] Other IiX solar Brief Desorption of Proposed Work ln,S ,f laY� 0tII pa q, ISFD , 0a QUeL, St LLf IDOf JrTC1I , Alteration of existing bedroom_Yes_No Adding new bedroom Yes No ^'� Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet sa. If New house and or addition to existing housing, complete the following. a. Use of building OneFarri Two Family Other b. Number of rooms in each family unit. Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e, Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attachedo h. Type of construction Is construction within 100 ft of wetlands? Yes No. Is construction within 100 yr. floodplain_Yes_No j. Depth of basement or cellar Floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I. L- EI �-';+ Cf+J�toi , as Owner of the subject property hereby authorize Valley Solar LLC to act on m alf, in all matters relative[o work authorized by this building permit application. 3 ' Signature of er Date 1, Valley Solar LLC as Qx )Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains 4nd penalties of perjury. fLIUQ✓l wan Pint Name �II�I18 Signature of Owner/Agent 7Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable D Name of License Holder _ License Number Lauren Harris _ CS-110400 Address Expiration Date 248 Ho a St. Greenfield MA 03301 7/11/20 Signature Telephone 413-824-7945 Qlatered Hoine IM yernent Contractor: Not Applicable D Company Name Registration Number Valley Solar LLC _ 186338 Address Expiration Date PO Box 60627, Florence, MA 01062 Talephone 413-584-8844 10/27/18 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§2SC(6)) Workers Compensation Insurance affidavit must be completed End submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. _ Signed Affidavit Attached Yes....... No...... D The Common vealtlr of Mtninchusefes Deparintenr ojLrdustrial Accideu(s 1 Congress Street, Suite 100 Boston, MA 02114-2017 unv,nanass.gav/dia \\at'kers' Compensation Insurance Afidavi F.Builders/Contractars/Electricians/Plumlters. TO BE FILED Wl I'll THE PERMITTING AETHORIT)'. .Applicant niform2tion PlItil Prim L bl Natne(BOat....ier,uaxanom'Ipolmduep:Valiey Solar LLC Address:340 Riverside Dr.,PO Bax 60627 City/Siatei Zip:Florence, MA 01062 Phone IS 413-584-8844 an....a, .nnlay v0...k ee vl prl ,,ea.. -- Type of pt olcct (requireU) 6 1 t n ,J. []ti ,nl,alaman lv n ladi k h. Q Rut adelbg p' (11 1.1ap 1111,Ior, 11I.1dl 0 J I'm 0 k lil,df IA i- can, lquIjsj `J. ❑DeHoin I t�l ld -1 d 10 Q Bmld n odddtoa v'r ....0 � 1 I.1 6.. ­11I lIlIa 111,4 ItIll 11 Ij. ILF] FIetr vrcpmrs of addins ' I2.�PIum ing repairau additiofmis 1 6 1 t nd ai_u 3.ElRo, eP-ain e 14 QOthe,Solar �tt J (c -dn pu a>iGL r_ 11,.oacis' .,nplI'll-fl,o I d.a -I III,, I,J A k Ia Ac al-rillolr1l,rl"11 ub II ndssinv c - b,.rb. 1 _.. br r. i.d. .da io,a Isll_r., nbcvbco ,d,a,.aim „ _ „lIn­n.._ pr e. p1 .,p p itt l urm ur enrple vu new is p,,vidi..w...A,,s'cel"'enlnn inaurnme jman,empinyeet. Belml,is the policy utdl we inlormidell Insurance Company Name.Berkley Insurance _ P ,Y i or Sdf-no 1 + MAARP301229 _ Eep,..auon Dem- 2/112019 Noll �iw.v«Wac 63 5-Nil e-A L_Cln� Vniell acnpv of sse'Aers'compensation police declaration pale(shoa'ing the p,lic7 number and expiration date). Fallell,to secure cr,ti-ave as vequ red tide:AIGC 2. ;25.A i. a final cioleimn j unicbable IT,a One LIP all Sl? o 00 and oT ..I,-1 ,, fell,so 'llas eLasell Ilprnzities al he fo rm of a STOP VVOR K 011 e nd afinc of up to S2,0 Of day apa,,ol the s lolmor_A co,} of Illu,lemeni ra, he fonrarded to the Office of In,-'-(_,.eons of DIA for Insula.¢ coreraee vn iRaation. ]A I oby mrtrh I'd /e(/b7tltar su d1 rtnitin- 71 l / (he urformm'innl ivididnbme iso avre, dcnrr r. oI Phone;.413-584 8844 Oficial use Ill Do unr invite to v/rfs nrcu,as he uo aplan d by in nr tmvte nJfciul Cit., a, ra - Pei ledUl.icense R Issuing Autherhp(circle one): 1.Board of Health 2.Bonding Department 3.Cin-/Tox'n Clerk 4.Electrical lnspeetnr i.PlueMng bapeelor 6. Other C,,akn Person: Phone#: City of Northampton . : / Massachusetts L DEPARTT T OF BUILDING INSPECTIONS ! 212 Nai Street eM nicipal auilding .� C- No[thae ton, HA 01060 Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: 63 �eFftetcQ l�� (Please print house number and street name) is to be disposed of at: Valley Recycling. (235 Easthampton Rd, MA 01060) (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: Valley Solar. (POB 60627, MA 01062) (Company Name and Address) j4q�� l �(lq Signature of Permit Applicant or Owner Date Iffor any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. r1 52 S. Broad St, FUSION Lansdale, PA 19446 --_ f27S)361-8040 April 6. 2018 Valley Solar 340 Riverside Or Northampton, MA 01062 RE: Chodos Residence 63 Sheffield Ln, Florence, MA 01062 Client Project$: 63CHOD PFE Project 7F'. 182084 On behalf of Valley Solar, Penn Fusion Engineering LLC(PFE) performed a structural analysis of the roof at the above referenced location. The purpose of our analysis was to determine if the existing roof system is structurally sufficient to .upport the new photovoltaic moudles in addition to the code required design loads.Our analysis is based an the information provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed. System Specifications: Total System Size'. 7.15 kW!DC Panel Specs'. (2 2)Panasonic -VEHN325SAI6 Inverter Specs: (1) Solar Edgge -SE6000A-US Racking System: Snap NRack- Series 100 UL The modules are to be located on the following roof plane'. Mounting Rafter Rafter Horizontal Collar Collar Tie Sheathing Shingle Number of Ceiling Plane Size Spacing Span Ties Spacing Type Shingle Layers Profile 1 2x6 16" l]ft. tin. N A 0" COX 112" Asphalt 1 Flat Shingles The roof design has been analyzed in accordance with the 2015 International Residential Code with design loads as follows'. Ground Snow(Pg) 40 psf Wind Speed W) 120 mph Mounting Plane 1 The calculations for these structural members are attached. It has been determined by this office that the rafters exceed the allowable span for the total design loading Attached are repair details that,when installed,will render the roof system structurally adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with 5,16' lag bolts at 48 on center maximum. Provide a minimum of 2"of penetration into the wood members. This office has determined that the installation of the PV System as specified above will meet the structural requirements of the 2015 International Residential Code and ASCE]-10 when Insulted in accordance with the manufacture's instructions. If you have any questions regarding this analysis, please feel free to contact us. or E7 Pest Regards, Penn Fusion Engineering LLC c� Andrew D. Leone, P.E. c . Principal S•Ary�AL E� Broa FUSION 152 S. A19 46 Lansdale, PA 19946 (267)640-2758 Client Name: Valley Solar PEE Project Number. 182082 Client Project Number'. 63CHOD Project Crocus Res.dence Address: 63 Sheffield Lu Florence, MA 01062 Description: Mourn ig Plane 1 Calculations By ADL Date: April 6, 2018 Roof Construction 2x6 Rafters at 16' on center A- 3.25 int Ix- 20.8 in° Sx- 7.S6 in' Wood Species- Doug Fir Larch k2 Fb- 900 Psi Fv= 180 psi E- 1.6e+06 psi Roof Slope 30 , Rafter Span- 11.62 ft Ceiling Attached to Rafters?. No Design Criteria Ground Snow(Pe). 40 psf Design Wind Speed'. 120 mph Live Load. 20 psf Dead Load'. 4.7 psf PV Modules. 3.46 psf Wind Calculations Directionality Factor(Kr), 0.85 Topographic Factor(iI Velocity Pressure Exposure Coefficient 0 (K,) Importance factor(p: 1 Velocity Pressure(q,): 21.93 psf Tributary Square Footage on 10.83 f[' Co.ponenc. Component Roof Pressures: 23.61 i -30.12 psf Snow Load Calculations Exposure Fact., C,) 1 Thermal Factor(C,) I Importance Factor(1): 1 Flat Roof Snow Loads (Ply. 28 psf Roof Slope Factor(C,) 1 Sloped Snow Loads (P,). 28 psf Unbalanced Snow Load 40 psf Member Calculations Bending Ma' 1083.84 in•Ib % 1719.81 Psi Load Duration Factor(Cd) 1.15 Stability Factor(CL) 1 Wet Service Factor(CM): I Temperature Factor(CT): 1 Size Factor(CO 1.3 Flat Use Factor(Cr„)'. I Incising Factor(Cd: 1 Repetitive Member Factor(C,): 1.15 Fe- 900 psi F'y: 1547.33 psi 1719.8b 154733 No Good In Bending Shear V, 373.121b f,: 67.84 psi Load Duration Factor(Cd: 1.15 Wet Service Factor(C.): 1 Temperature Factor(CT). 1 Site Factor(Q): 1.3 Flat Use Factor(Cm) 1 Incising Factor(C,) 1 F,: 180 psi F'.,): 207 psi 67.84,=207 OK In Shear Deflection Live Load Deflection (DI)'. 0.66 in L/212 OK In Live Load Deflection Total Load Deflection(AT)' 0.79 in L/176 OK in Total Load Deflection Uplift Calculation Tributary Square Footage on 10.83 ft2 Component. Uplift Pressure: -30.12 psf Uplift per Lag: -326.26 Its Lag Screw Diameter: 5/16 in Allowable Withdrawal per Inch: 490.99 lbs/in Minimal Screw Penetration'. 0.66 in Install 5/16"diameter lag screws @ 48 on center with minimum penetration of 2'into rafter. \ FUS7 1 c 152 S. Broad St. ION Lansdale, PA 19446 (267)640-2758 Client Name. Valley Solar PFE Project Number. 1 82084 Client Projea Number. 63CHOD Project: Crocus Residence Address. 63 Sheffield n Florence, MP 01062 Description: Mounting Plane I Calculations By: ADL Date: April 6, 201!, r New Sistered Rafter Size: 2x6x4'Doug-Fir Larch#2 or better Nailing Requirements. (2) I Od Nails @ 12"on center with(31 additional I Od Nahs at each end I Od = .12" hank diameter x 3" long minimum Note:Apply repair to each rafter under PV systen E e e •� a = WIN Client: � a Leigh Croups 63 Sheffield Lane ; Florence MA 01062 8 s go Protect Componaffithai 7. Racking:Snap N Rack Series 100 a Panels:(22)Panasonic 325W z 5 Power Opgmizera (22)SE P400 g e 2 Evtc...A wall of builtlin,. w gs Irnerter(1)SE6000H-US b AC Diiact Switch m Utdity Meter 3. Inle ralwalloductioing @ Revenue Oracle Production Panel Meter ;!I Mein Electrical Panel g m ge Aarv;»onol Wmx unin�Lnmowmini_Iw _ pit 3 D r ]w r - o N O N y A Z x 1 O ut N P � m or a s 0 h Chod Os Valley Solar, LLC. el.E„�M Es o,anla� vaA nwl vO ma I., N amean.MPnlcez PLOT LINES WITH HOOP 6] Hamid Lane pno ry SETBACKS F MA006] ]15 kWOCfi 6kWAC r £€ O EQUIPMENT SCHEDULE 0 CONDUIT&CONDUCTOR SCHEDULE 6 [TAGDESCRIPTION PART NO, NOTES TAG DESCRIPTION OR CONDUCTOR TYPE GOND. NO.OF CONDUIT CONDUIT y ,Y a 1 PVARRAY Series 100 Snap N Rack 100 Series Roof Mount System _. GUAGE COND. TYPE SIZE 2 SOLAR PV MODULE 'VBHN325SA16(22)Panasonic 325W PV modules 1 USE20PV WIRE• 10 4 _EGC - — 2 5 3 POWER OPTIMIZERS IP400 (22)SolarEtlge P400 — -Cu-- — s a - - - ] THHN 2�o XHHW 2po RH_W-2❑ 8 4 p 4 AC DISCONNECT 3R Nema 3R Combiner Box&DC Disco h@ EGC - 6 - 1 s $ } arca ) — $ 5 DC/AC INVERTER SE6000H-US SolarEtlge 6.OkW wl built in OG Disco&ROM 3 (THWN-2 or XHHW-2❑or RHW-2 fi 3 At SER 8 (@ house) _ EGC 10 1 -- —1RB —to 4 THWN-2❑or XHHW-N or RHW-2 6 3 At " SER 6 AC DISCONNECT DU221RB Square D 30(adjacent to utility meters A house) 5 THWN-2❑or XHHW-2•or RHW-2 210 2 N SE $�'g - 6 RACK BOND ON ELEC CONO 6 1 Cu Solid f T GENERATION METER GE -210+ Revenue Grade206A Meter .__._._ 5 $ 8 SERVICE PANEL I 240V AC.206A MAIN,200A BUS,30A Inverter &8 5 !t _ - OCPD 30 o0 E 9 —UTILITYMETER 883306312 1201240VAPH,3W Q Motlnlesl 2 1 • •� $ Opbmizers q nc ol.� To/From Why o String M 9 ih 11 WM <4w $ IT Meter 0(2 nq� , — M • Utility r Q g 6 F0 j€ 1 I vme5 10 � w € Js wkkm 8s " T Meter � � i tc a• $u • ROM 1 rw Mod Les/ =� 4 s' Optimizers in String • I � I 8 45p�q 2 5 tg is L IHTERIOR wv.. ry 79s 57 ---- —' q -- --- -- m g ° V EXTERI IR O M sk F p €� 4Ji�ounnNYllcy Humvimnmvm�m.lne. T' Panasonic Panasonic's unique helerolunction technology uses ultra-thin amorphous silicon layers.These thin duat layers reduce lasses, resulting in higher energy output than conventional panels. O Advanced bifacial cell designed for increased energy output. The cell untizes sunlight reflected back from the rear side material which captures more tight and converted into energy. Penas[nic t1✓♦ � � 1111111 High Efficiency at High Temperatures 25 Year Product and Performance Warranty-- As temperature increases, HIT®continues to Industry leading 25 year product workmanship perform at high levels due to the industry leading and performance warranty is backed by a century temperature coefficient of-0.258%/°C. No other old company-Panasonic. Power output is module even comes close to our temperature guaranteed to 90,76%after 25 years,far greater characteristics. That means more energy than other companies. throughout the day. Quality and Reliability Higher Efficiency 19.7% Panasonic's vertical integration,20 years of Enables higher power output and greater energy experience manufacturing i and 20 internal yields. HIT®provides maximum production for your tests beyond those mandated by current limited roof space. standards provides extreme quality assurance. Low Degradation Unique water drainage HIT"N-type" cells result in extremely Low Light The water drainage system give rain,water and Induced Degradation ILIDI and zero Potential snow melt a place to go, reducing water stains and Induced Degradation [PID)which supports soiling on the panel.Less dirt on the panel means reliability and longevity.This technology reduces more sunlight getting through to generate power, annual degradation to 0.26%compare to 0.70% in conventional panels,guaranteeing more power for the long haul. e i Ol.umB,sd solar - . • = • Single Phase Inverters for North America • • iii, 'HID � WgK'e 4 • 11111111/ �) 0 .v ' e 9 e e e e •- e � s e Optimized installation with HD-Wave technology Specifically deSt+ed to Workwith poweroptimizers Record h:eaktng efficien_ry r+xed ao4�ge inv:r[er for longer strings Int ed ac<ultp tenon and rand shutdown far NEC 2014 and 2077. perasvde 69011and 65012 U'.1741SA11,ttf d, for CrU'CRuie2kgridrompliance Ext er ly hall g — High Iiw bit/ ,art,ut any ele<Golvnc caoac`toa Y' Outdoorand indoor Vnstdllationwave Opttonab. Revenue grade data,ANSI C12.20 Class 0 510.56.accuragQ solar • e z Single Phase InverterSfor North America SE30o0H US 5E3808H-J5 Si.5000H-US 516000H US SE7500H-US Si,1000H us OUTPUT fAae , '. .. 1,j,-- .. 4CO [ �L4e11m Aem.- ! r J de. I d6d: oL r —31 NPU' is tl - g. .. . Ft, Ills ADDITIONAL FEATURESh L,v ,e,vi <aa vn M1EC �n STANDARD COMPLIANCE C INSTALLATION SPECIFICATIONS s L, ps n3 i vulcM1 112 1 Is solar - • • SolarEdge Power Optimizer Module Add-On For North America 25�e� PV power optimization at the module-level Up to 1;%r^,ora it r. . Superior eKciencv(9,9 5> , P t t 5,to oil typ o dine rn etch losses, fmm manufacturing tolerance to partial shading Ie L ,sic 1i oe,tnfor maxis m spa ce uti I z,,ron l,t pstallanon with i angle halt Next gene2tlon maintenance with module-level monitoring M reel , shutdown I oii inttaller andfreighter safety solar ' • • SolarEdge Power Optimizer Module Add-Cin for North America P300 P3110 P370 P400 P405 (mrm-cell mod- IbrbII RP r IID,M1"I"Power (no,73&46-cell If.,T"W, ul¢sl bo-cell rr oawesi 59­d 72 cell nwCvlu) mOOulet) mOtl 72z) INPUT ,.... ,� c ..� 12 ... OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED 10 C FERFSING SM AR EDGE INVERTER) u.. a_ OUTPUT LURING STANDBY(POWER OPTIMIZER DISCONNECTED FRO M SI LAREDGE I NVERTER OR 50;AREDGE INVER'i ER OFF) STANDARD COMPLIANCE F 15 oa TSc INSTALLATION SPECIFICATIONS Max FPO GY+" V,11,, L- In.PI 7 'nR Je I Lr vt.0 .I t •te .>- � caf L.a Lr 5' 4t, PV SYSTEM DESIGN USING SINGLE PHASE SIN6lE PHASE THREE PHASE 20flV THREE PHASE J90V ASOLAREOGE INVERTER— HD-WAVE Mlr. TLer R .. _.. SNAPNRACK SERIES 100 RACKING SYSTEM TYPICAL ROOF LAYOUT REVISION. NOTES: -STANDARD LAG BOLT SPEC ASSUMES 5/16" LAG BOLTS WITH 2.5" EMBEDMENT IN ROOF STRUCTURAL MEMBERS/RAFTERS -TORQUE ALL T6" HARDWARE TO THE FOLLOWING: ROOF RAFTERS OR -SILVER S.S. 10-16 FT UES STRUCTURAL MEMBERS -BLACK S.S. 7-9 FT-LBS RAIL CAN MOUNT TO EITHER SIDE OF POST(UPSLOPE VS. DOWNSLOPE) -FOR UNEVEN ROOF SURFACES, USE SNAPNRACK MODULE UP TO TWO LEVELING SPACERS PER L MID CLAMPS MODULE OVERHANG FOOT OR STANDOFF. SEE DRAWING t (NOT MANUFACTEEDURERS RS 'STANDARD RAIL LEVELING" FOR (N MANUFACTURER'S DETAILS AND LIMITATIONS RECOMMENDATIONS) MODULE OVERHANG r, i STANDOFFS ARE BOLTED INTO ROOF RAFTERS OR STRUCTURAL MEMBER "RAIL SPAN" DISTANCE BETWEEN ROOF ATTACHMENTS "RAIL END OVERHANG" (NOT lb EXCEED 34%OF ACCEPTABLE RAIL SPAN) "Al'AINSTREAM ENERGY CORP DESIGNER. GMCRree1— SCALE. DNS .PART NUMBE R. DESCRIPTION. REV l ply\UN �VU1J1- DRAFTER. oRy," S100 D05 SERIES 100 TYPICAL LAYOUT F 6�9 f0I®au w®oyahm .,..__':.::.. ., APPROVED BY. °nre 120113