Loading...
31C-035 (10) 80 MUSANTE DR BP-2018-0983 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31C-035 CITY OF NORTHAMPTON Lot- PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2018-0983 Projects JS-2018-001791 Est.Cost:$26936.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor. License: Use Group: PIONEER VALLEY PHOTOVOLTAICS 111266 Lot Size(sp. ft.): 21820.68 Owner: DRIMMER GARY zoning: PV Applicant: PIONEER VALLEY PHOTOVOLTAICS AT: 80 MUSANTE DR Applicant Address: Phone: Insurance: 311 WELLSST- SUITEB (413)772-8788 Workers Compensation GREENFIELDMA01301 ISSUED ON.41312018 0.00:00 TO PERFORM THE FOLLOWING WORK:INSTALL ROOF MOUNTED PV ON ROOF - 18 PANELS - 6.48KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signature: FeeTvpe: Date Paid: Amount: Building 4/3/20180:00:00 575.00 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner ervtU ?C; DepaNnent use only City of ort e, ofpermR: Building r „ r+e;, -o us orb.CWDdveaay Pennd 212 Main Street SewarfSelal AvaPidXlky Room 100 WeterMfell Availobft Northampton, MA 01060 Wo sets ofStruqural Plans phone 413-587-1240 Fax 413-587-1272 wisfisPurrs )OW Bps* . APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Procertv Address: This section to be completed by office U 80 Musante Dr, Northampton, MA 01060 Map 310- Lot 03,5- nit Zone Overlay District Elm St District CS Distrkl SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Gary Drimmer 80 Musante Dr,Northampton,MA 01060 Name(Print) Current Mailing Address: (312)316-9088 See attachment (A) Telephone Signature 2.2 Authorized Anent: Pioneer Valley PhotoVoltaies Cooperative,LLC 311 Wells Street,Suite B,Greenfield,MA,01301 Name(Print) Current Mailing Atltlress: !� 413-772-8788 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permitapplicant 1. Building $6,628 (a)Building Permit Fee 2. Electrical 20,308 (b)Estimated Total Cost of Construction from 8 3. Plumbing Building Permit Fee (f�� 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) $26,936 Check Number This Section For Official Use Only Building Pend Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings ff Date Section 4. ZONING All Information Mus[Be Completed.Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filldm by Building Department Lot Size - Frontage Setbacks Front Side L;-R:', L_ R Rear Building Height Bldg.Square Footage Open Space Footage % - (Lotareummusbill,&pavM _.._ #of Puking Spaces - Fill: (volume&Location - -- -- A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW 0 YES O IF YES, date issued:', IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW UM YES O IF YES: enter Book . Page.. and/or Documental B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO 0 IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES © NO O IF YES, describe size, type and location: E. Wil the construction activity disturb(clearing,giading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Stonn Water Management Pend from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alterations) ❑ Roofing Or Doors Accessory Bldg. ❑ Demolition ❑ New Signs [[I] Decks [C] Siding[[I] Other I= Brief Description of Proposed Work: I . 11o-.1 w1.-1ro,Imre 1. n �r 1—mor Alteration of existing bedroom_Yes X No Adding new bedroom Yes X No Attached Narrative Renovating unfinished basement Yes * No Plans Attached Roll -Sheet Its If New house and or addition to existing housing, complete the following: a. Use of building Onel'arl Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction I. Is construction within 100 ftof wetlands?_Yes No. Is construction within 100 yr. floodplain_Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1 Gary Drimmer as Owner of the subject property hereby authorize Philippe Rigollaud to act on my behalf, in all matters relative to work authorized by this building permit application. See attachment (A) 2/21/2018 Signature of Owner Date Philippe Rigollaud , as GwnedAuthorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. PHILIPPE RIGOLLAUD Print Name � 02/21/2018 Signature of eA7ent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Summisor: Not Applicable ❑ Name of License Hold.,:Daniel Gomez Gonzalez CS-111266 License Number 43 Hatfield Street . Northampton MA 01060 _ 03/14/2021 Address Es,son.o Date 413-772-8788 Signature Telephone S.Registered Home Improvement Contractor, Not Applicable 0 Pioneer Valley Photovoltaics Cooperative LLC _ 140077 Company Name Registration Number 311 Wells Street Suite B Greenfield MA 01301 09/15/2019 Address Expiration Date Telephone 413-772-8788 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. _ Signed Affidavit Attached Yes....... 0 No...... ❑ 11. - Home Owner ExemWion The current exemption for"homeowners"was extended to include Owner-occupied Dwellines ofone(I) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section Definition of Homeowner. Person(s)who own a pzrcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling.. attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building OffiJal,on a form acceptable to the Building Official that he/she shall be responsible for all such work performed under the buildine permit As acting Construction Supervisor your presence cn thejob site will be required from time to time,during and upon completion ofthe work for which this permit is issued. Also be advised that with reference to Chapter 152(Norkers'Compensation) and Chapter 153 (Liability of Employersto Employees for injuries not resulting in Death)ofthe Massachusetts General Laws Annotated,you may be liable for persons) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assume:.responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature __ A } ,,)rvwy�t 4 AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT I hereby agree to the Project as set out above, and I agree to pay the contract price accordino to the Terms o` Payment. I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement. hereby authorize Pioneer Valley PhotoVoltaia Cooperative to proceed with the above-referenced Protect in accordance with this Agreement. I further authorize Pioneer Valley PhotoVoltaics Cooperative, or its designated representative, to obta.n required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project:to be used by Pioneer Valley PhotoVoltaics Cooperative for marketing purposes.A check for the Piny Payment is enclosed and I am returning this Agreement within 21 days of the Proposal date. Printed Name Date Signature Title rr000sai an0 P r.rncm a 00012291 Paye 1 or v Gary Dnmmc, Janaary 2.2010 :,nrnmon all tt •al `d asc a<_hu cett� UPn S,ttn ti Pr C�fps Su,nal L.0 EP sure Bodutnq Requialioas ann Staitgasns -S-I ' * 26n G ?021 DANIEL GOMEZ.GONZ4LEZ a„r 43 HATFIELD STREET NORTHAMPTON MA 0'1060 .�unvrissa^c' �. ACORo' CERTIFICATE OF LIABILITY INSURANCE pATE'N".np'""I Dv0a2013 THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURI ISI,AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT. If the Certificate holder is an ADDITIONAL INSURED,Me Balicy(ias)must have ADDITIONAL INSURED provisions or be,endorsed. N SUBROGATION IS WAIVED,Subject W the terms and conditions of Me policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemen(s). PRODUCER C.O LIMA PPWers W¢OOet B Gunnell PxOMEF5H13)=u86-0111 (413)) 5865431 2.101. B ROHL OFG Street Appi5: PONErs(Tw2bbPrand9nOnEll com INSURENSIAFFMMO COVERAGE Bur Northampton MA FILED INSURER A. HDI FOODS IDs.CO'Ener9i INSUNE. NUMBER B: MIUMII'Eii it Pioneer Valley PMIOVrooics Cooperative l IC RIMIN RC. ItEiI Ins C00f Han00VWIEITI Ann KO PONham INSURER O. 311 Wells Street Suite INSURER E: GlPenfield MA 01301 INSURER F: COVERAGES CERTIFICATE NUMBER: Master E.,1-2019 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELON HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT TERM OR CONDITION OFAM'CONTRACT OR OTHER DOCI IENT NATH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. E%CLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID C WIdS. LTR IF OF INSUMNCE INSID VARD POLICY NUMBER REMS! YYTY) U."Do YYYI LIMITS C7ERCNL GENERAL LIABILITY E5^n G:CUftftEACE £ 1 000 CUR'S-N iGE ®LOLVG PRCIgEE6 Fe o:anewe' ° 100,000 NEO OF uvl ore 1.11 t Excluded A EGGCR0002412118 0F101p013 0110112019 PEACo IIIAD IN1ueY 1000000 GEN L ITAEGATE LY T A"JIFPER GENEFwLAGGUii 2ODDWE Palcr❑:Er,�1 ❑Loc PRooucTS-covP/o=rrw E 2000000 LT" $ AUTOMOBILE LIAMLLIY IOrII eT. In `• s 1000000 v>VTO BODILY InNRv(Ptt cersonl 3 q CINED scnEpJLE EAGCR000241218 011012018 01/01/2019 WD'y.......AV :D", 5 rOE1I A1-O5 LINED ODIC%'ED PRDPEBTYDAOIAOE s A170$C,, .cToswLY m._ aem� Underinsured m toret BI E 20000 UMeRE¢LAUBB = EiiUUCCUIIFmE E 3,000000 B EXE[ss LIAR D.usls IIABE 18EFXNi 01101;2018 01/01/2019 >LCR'oerE $ 3,000000 DEO PETITION• $ WORNE RSCOMMNSMRN AND EMPLOYERS'LN&Litt $U'VTE ERH Y x 1000000 A ArvYPROPRIVER/PARwEwExEctlrn'E I❑ x EWGCROOD2412118 01/012018 0401/4015 EL PATH ADGvoervr s OFFIc=_RiEuaER FxaVDEm 1 000 11, UrryP r EL DSEABE EAflnPLOVEE 3 cFF-EI 7IC1 o°e' 1 1.000 000 Er_RIFnoN of oPEaFnDNs r,i�o« EL mess PE.Po_ICY urart Bpamee:Per:Pmpem 51 5350 0000 DO) Commercial Pmpeny C CPRt8E17801 01C1 2018 01'01/2015 Installation 8350000 DESCRIPTION OF OPERATIONS I LOCATIONS:VEHICLE (ACORD 101.As itlmal N—i salieOUIB,miY ee iNdiM R—No—Is repulrRL CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE FIPIRATON DATE THEREOF,NOTES WILL BE DELIVERED IN Evid¢n!e of Ins Wart:e ACCORDANCE WITH THE POLICY PROVISIONS. AUnbRMEO REPRE SENTATNE ®1988-2016 ACORD CORPORATION. All dghb reserved. ACORD 26(2016103) The ACORD name and logo are registered marks WACORD The Commonwealth of Massachusetts Department of Industrial Accidents I Congress Street,Suite 100 Boston,M4 02114-2017 - wwrrmass.gowdlia \Corkers'Compensation Insurance Affidavit Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH IME PERMITTING AUTHORITY. Applicant Information Please Print Lecibiv Name(Business/Orgmization/Individuap:Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar Address:311 Wells Street, SuiteB City/State/Zip:Greenfield MA 01301 _ Phone# 413-772-8788 Are you an emplay O Cheek the appropriate box: Type of project(required): I.❑J I am a employm wild 48 employees(full mNor pan-rima" 7. ❑New construction 2.❑Imnemte proprietormparmerstip anahavc vo employees working fmmem g. Remodeling capacity.INo workers'comp.insuaucc required.] 3.❑l am a homeowner doing all work myself[No workeo'mmpinsurance required J' 9. ❑Demolition 4.❑t am a homwwner and will be hila tactors to conduct all work on 10 ❑Building addition g con y propmy. 1 coal ear me that an cmtrauor eiNctlure workms'wmpmsatlon insuranpeor are sole 11.❑Electrical repairs or additions proprietors woh m employ«s. 12.E]Plumbing repairs or additions 5❑I am a general centracmr ma I bare mmil the aubconmcmrs lisad on the atreche sheet. 13.F]Roof repairs Thex subcontractors have employces and have workers comp.ansuomce. 6.❑We am a<orpoation and in officers have exercised Web right a.'exempnon per MGI.c. 14.QOther 152,§1(4),and we have no employees[No workers'comp.insurance require_] 'Any applicant that cheeks box#1 mast also fill am the seance below at owing their workers'compensation policy iNorgagoon. t Homeowners who submit this amdavit indicating they are doing all wr rk and then hve outside contractor moat submit a new affidavit indicating such. lConaacam,that chink this box mus[attache an additional sheet showirg the mete of than subcontractors and state whether or not those entities have nnplayees. If the subcontractors have emplayeee,they must provide Nair workers'comp.policy number. I"an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:HDI Global Insurance Co/Energi Policy#or Self-ins.Lia#:EWGCR0002412118 Expiration Date:01/01/2019 Job Site Address:80 Musante Or City/State/Zip:Northampton, MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL a 152,§25 A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties it the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be--.'orwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains andpenalaes ofperjvey,that the information provided above is nue and correct Signature: /[f=_ Date �'� ' 2/21/2018 Phone#:413-772-8788 Official use only. Do not write in this area,to be completed by city or town official. City or Town: _Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.Cityf Fown Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: a gau4'Q Drimmer - Northampton rr Southern and Western Roof ACPV Array (Asphalt Roof) Owner: GaryDrimmer ddress: 80 Musante Dr _ Northampton, MA 01060 Phone; (312)316-9088 e-mail: garyd7@yahoo.com �• System Size : 6.48 kW DC PV Arrav: (18) SunPower SPR-360 - ACPV: See sketch for layout Mountine: Invisimount racking on L- feet on Quickfoot bases Roof Structure: Southern roof is 36.87"and Western roof is 22.62°. Trusses. Roofing Material: Asphalt shingles Notes: New construction I i r< New England Construction Engineering, PLC 436 Campbell Street (NECE) Structural Construction Solutions White River Junction, VT 05001 Jonathan Rugg, P.E. 603-903-9798 i.rugg@NewEnglandConstructionEngineering.com January 30, 2018 Ms. Miira Gates Pioneer Valley PhotoVoltaics Cooperative, Inc. 311 Wells Street,Suite B Greenfield, MA 01301 Re: Drimmer Residence, Florence, MA PV Squared Project No. 11953 NIECE Project No. 18-001 T-72a Dear Ms. Gates, At your request New England Construction Engineering, PLC (NECE) has reviewed the information that Pioneer Valley PhotoVoltaics Cooperative, Inc. (PV Squared) provided on the roof and supporting structure of the Drimmer residence,at Lot A27A,Village Hill, in Northampton, MA.The purpose of this review was to provide an opinion as to the structure's ability to support a proposed rooftop mounted photovoltaic(PV) array.The information that you provided includes, architectural plans, and engineered wood truss plans; both are attached to this letter for reference. You are proposing to erect solar panels on two sections of the house roof. The house is a recently constructed two-story story wood framed two-family home. You have provided Architectural Design plans by The Pecoy Company dated November of 2015.The roof is supported by manufactured wood trusses at 24" O.C.You have also provided manufactured wood roof truss design output from Universal Forest Products for these trusses.This truss design output bears the seal of a Massachusetts licensed Professional Engineer and is dated May, 2016. You are planning two PV arrays.The south array is on a 36.9-degree section of roof.The roof is symmetric about the peak here, and the trusses span approximately 21' in this location.The top and bottom chords, and webs,are#2, 2x4,SPF.The trusses were designed for a 10psf top and bottom chord dead load, and a 40psf design ground snow load (Pg). The west array is on a 23.6-degree section of roof.The trusses here span approximately 33'.The top and bottom chords are a mix of MSR Fb=2100psi, and#2, 2x4 SPF.The webs are a mix of#2 SPF, 2x4 and 2x6.The trusses were designed for a 10psf top and bottom chord dead load, and a 40psf design ground snow load (Pg). New England Construction Engineering, PLC PV Squared—Drimmer Residence Jonathan Rugg, P.E. Northampton, MA Page 2 of 2 The design plans specify a structural wood sheathing roof deck.The roofing material consists of asphalt shingles. Conclusion: Based on the information that you have provided,we conclude that the roof will adequately support the proposed PV array. We base this opinion on the following assumptions.We assume that the residence was constructed as designed, including the installation of all required lateral truss bracing.We further assume that the FV panels will shed snow more readily than the existing asphalt shingles. We also assume that the panels will be installed parallel to the roof, eliminating any additional wind load.The g'ound snow load (Pg)for Northampton is 40 psf. Based on information that you have provided on similar projects,we assume that the proposed PV panels weigh approximately 2.6 psf. In summary, the roof will adequately support the design snow load and the additional dead load of the proposed roof mounted PV array. Thank you for the opportunity to assist with this project. If we can be of further assistance, please contact Jonathan Rugg at NECE. o11tOFwS'p- Sincerely, JONATHAN A .n o' RUGO 7 " No. 51882 A-nathan Rugg, P.E. �l New England Construction Engineering, PLC. •�Ctt�sq/ Attachments: Building information, C✓ V P S m A N II C y_ 6 e ( a E I � . a . I� 2 4 c o e °t C n d I S pp NSIO?S DEStRi FO& THE DRIMMEA RESIDENCE _ GG LOT A27A • VILLAGE HILL TM '0. HA eG„ 3 ~a wl tiLCayyl�'.( I l3ls[3tld �; A Hl weWelS(5135tlJOtlOI I ' slVlp iA?aD WesMRua eylWtarn spm wtow Npy p+a�apuuw,R VOUIDpqu!ryeugyala p6viwaS.(OL ! 'l Id195Ntl p+apuWY tasuaala/Wa iBL 2WL pn!'L l ZOStl s.nW88WJ mpigpmtl IawgawaVq FALL a41 Ww auepave'n.peu&np c.6SM Y!411fi 'L>I�BSZt4(qkN Idaara(s1Wp11e IpMn pl W L 6wpuvlsVlvn p apaHp alela fiupnp of�e w(sHyw Rq)mV:au4m IaweQ-aw apnoy IH IK00 L=M]B VIM'sipuuw:ayp Aue p4a pcp vuuw aUluawaVgll✓a apvnO4E Aq 4plle P9E a!fiuelv�ea¢VA ew Aue puip uwupp aipw�0KW08al (w6!spsspl xrw s!VG.(L spNlaeX NWONu�waumuv-wuo o, Upttry wlp/pw UnvW lsd 'Ot eigqu68a0 U.spV.ssrvl siyl(91 Klgpm aswaVlp sa',un weep OLlry ara saleq Iry(s '. a.!I�ayp VlM lwunawswusNeyaro la lsa O'OYW DnIp'i 18Ybwp WL/p1p1P9lpKpla'+wlpw ww s .-pzu waw o.�paao'OIa Mw: N�a.�woh,m.wn(c L t=IJ'E*3 RIIeNed]dv3 11 AU�aIeJ Excucpo.Iry118a PO%H'SPL 3]Stl ll]112 osL=ICO a!fia1M OB 1=10'J aVw�l'.uxrys sw!pn.M$nYNV9�M Wes�4gwry yJ:Ksoa.a 1118V1 wl w:nYas We'pamEn U. WeWI/avlyunlawx(LI^48V3}JWa(asaaq)Stl3MlY'pasalaw I]Ev3'llle]4pi=V'6aB's=l]J9 Isa05=IQJl w.,SPG 3]Sb 1 (L 5330M SLBVOLP=B-G LSW92BZ=fIS 991IWY-B9'9LLUP'f=0L5'EB>/eLZL=OPO'Sf92tL-=ZI O'HLUfiY-214 s83M ..11f=OLt'LBCLJ6h1101'LBEL5pS—ll% 1BfLM4P=SL-LI LfifL —2pL L'>BHE2B(=f LQL Po 1O9 cesreBel-=Pe 'HaT/69=EtEZSL1161-190£49]OL-=S19'LL4E902�11'oLBR>BL—pL54855BLl=Yt->ZBHNM—bi LBLpH4=E-2 d01 umys uay.ulWMa ml p(gl NZyawl las- ual YaYVdwo] (q, -1 ) 33]HM (f T1GOF=H'HLLskx¢L=LWIan 1 V "H-aw (LY4 wwl Bf'NY=6L=H'fo-E�O u�w)gyryLW24L fawiW 9NgLltl3tli 2oN 3dS 424. wm3 'iuoeqEL4 O4'9'OL'> EWp!w V Leal.vPtl&B4 S93M ,I�v3 3HL'4 Ip s11 ImIztl50eE2KB JS913R spOLmWd. 8m M p&9 Oy0HJ109 2CN 3dS p2'Ll s18+.Yev WalaaLa'suwndx PZ-L/opo!Iaae Alp4gfiw41aaVs papas lr•'Nr41$ 0$gHJ d01 .Ian.3.3BL jW{Z 3dS O209g1]dOl MIIJbb9 tl39Wll .t=13 gfet IVGe. 03C bB0< 2tro 00 Illvuya Iww/1) GMZ• lu/6hYJtl aMJ OOi N aN H OLO ML w0 9M 53A Ws�Sdad 90 IIJB ZISIOLLIV Wt lzla tO MP (IU BHO JB EtL Y,q¢gwnl 90L l0]i MVLBL WLV Opt W" it9 SBP (NKA te'0 Ol SSL IZZI, 1 fOtlY-^'au51a"MI d.0 53 d Dn uapn ( lf3a 'ml o-ukL Onlords °(�pe)9xll Ol _. --- 2LY9PE4EL LLT9'-0L PEa EL 9 _PEU p3' L-tOisL9LTr8'o-02o-Lq-9'PZ4Gi'OT'SP 03 Zf�' lid-Of.TPL91 60 �X We'l�W e_IeN, osro - u-rs srIz PPpL PtZC � 4 i4i L 48 L LLY/e �.L ,L s✓n 6o-pP pr�"_avo4°hlR�W.B.�=".�8.°h"�sak�0e45F},'xpP3�-a HwexnsoaxwnLrnsirxlv..ol ,., . N o � T¢sTps IVwxMjfll$elt M%CO6VX3yyX niueu x® �cuwx � . um -Avfw _- - JS ReMerar I IN,- 10-z-li 1sT1z ]' °�A2PtLd?MIYi��P4:V:�PA ' 1rltza�a ' 451z 9s0� m= a4= 1z 11 s rM _ 2U B].0 �- 611-0 Pb1e CYbe6 r,rr�o-3u ow - -- -- LDSONC 'a) -- -- -- iCLL dp,0 SP�CN(i SDD L&. OFFL in (bcl 6aeM1 IM MIES GMP Ro95mv-0p0 RSUt GIp COL 115 TC DB] VerlLLl U.fO i8 =9W 4W MRO 19]/144 iCDL 1G0 L+^'6wa'L 115 BC 059 vwgR) D.1B i-0 >909 tE0 BCll 00 RWS Ina VFS WB OW IbrtlTll 0.03 0 Nv Ne T 0A CftlB IgCX�?PIA3] (MMIU) NSIb.'LL) O.2 ]d =999 3W WwfIL1051p R=4% TOPCTIC BR1CpIG. XJPD d45FF W3 TCP CXCQV SNtlurel weM SliaNlrq olre]IyaagiMa22DwPL61n,eYepleM wNsb. BOTCHJPO 2n45PEtb2 WTCR D ROE xAiW EireclN aRlip2w1000 xpnmg. W n .45FF Not gFtC1tlN4. INNx 9Y2060GA(mm.0-M)6-1 WN (m,n 0.2D) MaaX "I%LC6) Msa LgXY}-DylG 0y6=9MLC 9) FORCES (EI-MarC PMx.T -MW2%(Ip)wl¢sucetl sMvn. TCVCIM 2lD—l0TM34,110-10114053-11-IDi W55AJ1=-106)144 WT CXCRO 69=:21 PRM.612=-] %,1213-.MW.T13=-]9n096T=-R19z4 WE65 3]=1141405,4.7-24Y2E,3 =1]4146528-24&M 29=13692424 A=l NQ141 1)Wnd 1)J .0.9CE]-0s:1Wnp1:]col=s Optl:BCOLS Cgs1:n=24n:CeL II'.ExP c.mclmM:WM1 % nsaae)aMnb Etlwizl WM.agdpWLlW ri011e�N:erq wqd kM1alk rp'lIeN4B1;GCM mwnpers eMla�SMKFgS br msAms511om Wmpv WL=t W ge1e 911P WL=100 2ITLLL'.A9GE]-0s:PFJ00 ps110a1 rcalsn'wl'. IpwY IL,Fap C'.PaNaWYEIp,:CI=11 311`ha B1snw kmCs MW Mn mpEpel y19s Emi;n. 4l Tlllal..sM paerr pspg]br a t0.0 W WYpm tME Ilre baE nwmlwlre'llxip eny Ma 4vx Im65. sl'mn.nd ny pttn ee .naNre aaa✓mOP9an ub Damm mwp mau.lesawNreaiecbri9le 36D mn pr zDowoevallfiloxwcen ulapoeom awre•m anva�mempa�..m 9ca-109PM. _ ])�rs Wun ouvgnM nl swoon(wvM tle AN Im meLma PesNminl Coh eevwlv)R502 11 ..M.. anE reMw A alanoaN SH5U1PI1 B)'Seningo pltliprssks IMUSy segs'Hamper erq fwly mMtl was useo in Ms awryvs eM sesig�M pa pres. Lwoc4sEry)sMmare tM Gi i JGNNM PRESLEY �na aW16 w '. b "G15TE� I �aJ11µESLD+ F h [ ....... . PROJECT INFORMATION: B sQUA • /meq Owner: Gary Drimmer • Address: 80 Musante Drive Northampton, MA 01060 ar��I// '•. . . • Phone: 312-316-9088 __ _ W Squaretl Solar 311 Wells • Email: garyd7@yahoo-eom hreet Suite B_ creennela,mnm3m _ deeigh@11gaared.eooq • System Size: 6.48 kW ` al3-77 8788 • Modules: Sun Power X22-360-D-AC ` JOB: Drimmer • Rail: Sur-Power lnvisimount ---- • Bases: EcoFasten Quikfoot Sire. aB Mr:amr on, • Snow Load: 40 IIs Northampton,MA010W • Wind Speed: 120 mph REVISIONS: ROOF STRUCTURE: - - • South Array:37a slope trusses @ 24"O.C. • West Array:24°slope trusses @ 24"O.C. ROOF MATERIAL: Asphalt shingles throughout Space reserved for SSM-R2 other condo array. PROJECT NOTES: /1 Site Plan 1. Framing location to be verified on site. 2. Slide rail assembly as needed to avoid interfering with splices or bases. BILL OF MATERIALS 3. Unless otherwise noted bases are staggered CR PART MAKE MODEL and spaced at 48"O.C. 4. Additional or alternative bases may be used 40 Base EcoFasten Quikfoot TITLE Site Plan to meet actual roof conditions. 12 Rail Sun Power lnvisimount 24 Midclamp Sun Power lnvisimount men: IISI BY JS 24 Endclamp Sur-Power lnvisimount DATE'. 30112018 18 Module Sun Power X22-360-D-AC SCALE. a:Shnwn 3 Snowguard Rail Alpine Snowguard 8'SSM-R2 W/C1-69 Color Strip SME. 8.s^.11 2 Sowguard Splice Alpine Snowguard SSM-R2 4 Snowguard Bracket Alpine Snowguard SSM-R2 A-01 4 Snowguard End Bracket Alpine Snowguard SSM-R2 Imeen orzl Clamp Torque: 85 in-lbs N ,� Roof294" � L-Foot Torque: 375 in-lbs + 'r Array 248y4" Max Span: 48" y O Max Cantilever: 113 adjacent span # e.g 32"span= 10-2/3"cantilever Module Size: 61-5/16'x41-3/16"x113/16"(461 a N PvS"oaretl Solar m -- --- ---- ----- - ----- Array t0 be flush with 377 Array seeel,Smree ridge and gable to allow G,e-fidd MA El381 -- _ roof for other condo'sacn§n@pn4�a.etic.up array. 4137728788 4 IDB'. Drimmer I � N — Use blocking or decking rvo,vnampmn MA omso —. attachments as needed. eEvrslorvs'. I I Array to be flush with ridge and gable to allow roof for other condo's array. y- Array 125Ytl" � II rmE: Array Layout /Spa,,araysl Nand stagger to hold snow. FDNM: 11953 BY JG DATE'. 3/21/2818 L-Feet above rail at bottom of ' '. array only. Below rail otherwise. SIZE 8.5"x11" Alpine Snowguard SSM-R2 /� on South-facing roof A_02 (meet 2r 2) a ls SunPowerl X22-360-D-AC Residential AC Module Series Design-Driven Advantages el module aesthetics and efficiency' Unmatched module reliability' SERIES No electrolytic capacitors 25 year combined Power and Product Warranty California Rule21 Phases compliant Maximize Value for Roof Size system for roof, not string inverter Optimize performance of each module [7 Expand Deployment Options Comple,,roofs and partial shading Srn@fl SySoPMS Optimize System and Inshallat on Efficiency System expandabilicy S,jriP,)v,(,i Ac `TILJ'11110sAl Cl include a factcry irtegrated Sur Power Simplify& Speed Installation mi,roinverter provide a e Anio,viy c ,Minstior of high eff(wi i y F igr Factory inneguated morisinverter cli,bilhic and Morrie level DC to A( poser or.xsecr Designed Robust,double uchngAC connectors Design flexibility offsite and prone specifically for use with SurnPower invivilblounIT" in(,the AiiiPcower No DC string sizing process clouninoijois System,San power AC i enable rapid it stallminoi hcu Fewer installation steps than competing it-class qY, Pin acts he , ,1 (1 11 Unite ioiliu, No z1vie, [Dert,,rarce systems Intuitive commissioning All this comes..-in the best Cierbirod Power and Prodi i win any in the industry. Component of Complete System Built for use with Sur Rr,xer' I rivincrount" 3rd the S.iriPawpr boorlizoring System(PVS5x) Grid Support Utility-Interactive Smart Inverter SLJIJFric)r system reliability and aesthetics rul-Po,ser 1,r ea -) r module it I JL ce-Lcu and certified G UL r741 SA andlti,inie, advvrced nanirvertev fir cut,r sv ii iro,,e A,1)A( or I,, cr,,fAP),, unpliar, with the Calirorr,a Role 21 Pnae r f0flLu[ri chic and the Pule 21 grid flioni,it e tilt ret J, i r(iiiiini,vuin vi h t r Fn ^t PISS, rrornit,ing haid,afe sumpower.corn -,v, SUNP WER' v SunPowerl X22-360-D-AC I Residential AC Module Series IEEE 1547, 2014 CARuc21 SRD Frofil6 (default Soar Set ./ mmJ nom./max. '�___ _._._.. . __.. _. . _ mr../nemmax Frequency(Hz) 595/600/605 585/600/605 I'oael Force, 099/1.00/ 100 OSS lead rt OC 1085 lag. Rea¢ive Power 169 1,at _ Volt-VAI Vo tage E1240 V 2 11 2 C 264 V .'208V ifi /201 222881 Mzx Luren[ (2901 1 54AA C:205 V 1 - __- P 240 DC aC t( .onversio-F15cency V 96 DE; (2G820A_V 955% Max.Units Per 20 AR c Circuit 1240V 12[ ingle'IDase) b,2(2 10(:ec pcle;m,o Power 320 1,1 -MVA No T.i,e phase balancing fora pease if,scal scans - SEE Q236GD-AC 25 yearlimted po e arrarty Pon,nI Fo( e-(Pncm; c66 N �yEar Im ted p d n warra-ty P.",1"'I"a'Ce Ul r6tee cv UL1741 SA Aeg Pane,Efficie-cy 2229, 3RDS:IFFF 1547 2D03,IEEE 1547a-2014 CA ;e11 beef.(Poser) _ (°tr C Rule 2l Phase) Three hgpass diode, PV Raoid Shutdown Equome^t Shade Tolerance I-to,'seen mec ele.elnaxm Ill11,1, far< EGuloment Grounding vackrg _ U.6703.UL 5703 Connecta,and cab.es (load break dlSConnecii)P: L_1741 AC Module;lyce 2 file eating; Oper.tingToms 0 F so I 18 F( 44 C1_+85 C) C crt fica:101is E Sblpe nicalkit felt inaccord, ce oith. Ma 4 enlTemp 12 FIPO'C NEC 69C6 Ma oat Vi,d 621 300OPa1 xgPr2fro tS ack AEC SCC 12 R P d Shutdo . r (1 15CE d 0 145 as 600C Pa Ell kg Isr. t.rsioe the ai ' Impact Resists se l .n( 2y 7 ter I a:52 myhSIC r'5) NEC 691 Cc-11a1 6 )33(/17- (F),p K( one ICES-003 Class B Fe.-sed 1h lr N :mi L 0.,LP03) ' SolarCelS _ 96Mon Iysall eMl rn( III H,I to e peed�4^• a r tegat re 1d ganc a -_ rro [ a2s ml - _ Class fire rated - - - c lecti�sra,coatie -. PID Test Potent iaflnd,cad degradatlonir PT Er, rnan[al Rating Outdoo,,rrate _ - - - Fare C loss I. ka od dfh1"esAAI gl r oz�r V'S 1 45 5 he 06 Rsccfe ded had, and, 1 tdut a F I o t wmm r(z nl 6 , ®�eiw e -F f, I e � ^I I I �rIfl3N� U r°s r I(r i<II I, i r dneJ^ ye♦yq�ryypa�p Rr+ s. . Simple and Fast Installation Integrated module-to-rail grounding - Preassembledmid and end clamps I totalling mid clamp for easy placement Mid clamp widrh facilitates consistent,even module spacing .z. Simple,pre drilled rail splice -L 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management Customer-Preferred Aesthetits ttr module and41 mountingaesthetics Best-in-class system aescherics Eegant Simplicity Premium,loss profile design Black anodized components SunPower' InvisiMount" is a SunPower-designed • Hidden mid clamps and end clamps rail based mounting system. The lnvisiMount system and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics. Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and Bestin system reliability and aesthetic Conbine with Sun Power modules and engineered to pair with SunPower modules. The resulting moriforing app system level approach will amplify the aesthetic and installation benefits for both homeowners and installers- sunpower.com oo— • •wer�`� lnvis!MountTMResidential • .10JUI 71 TF arJg4 y I se ucirp aRJ a,l U.JClamp cr-'I:Hm'p R IAC')1ISpnce JL,,;1,tC)' c'JCap Corrporer, .areal eDr- Te ,eare i msa ' >•Rc,4cr _.._ ..P' J,Fr - orce k"�e aarrp Baa r see � „ aD -zoo sn to nCck Cd J, r,Fr rr g ,,s nC sail 6Nd tl M ,n II _„ iL a � X J,J S a AIJr' CHIC 6805-i= l ,ea, p ...r m% Gro JL Jam , . ia ne. IA7 7C c,, I . EW C.n9.,ck el P� k1%,I'_ __. ,L a,Liscc u ..a rc .tetl Co p[ CI 11DIN -,t _ kph C Co I C9 t F C- c !c Fir r ;Pca -t t, d., _ Ic iae rt...0 V- �I oce 4C F �i'crf, 4elano - Prcr["arc ,ueRi` J-C _Iaoor. M otl u l e lAm,'h17z Am,Ale miN hie ir,,a. , vcqu,, dbi vicneremi ogzo o"IS.-P—rGwpo-A llRb[ Arerz5 MN F. tSUNPOrEk I,ar A I NV S NOU.,i a I dJ& rks0 m—1 ratlenarkz OF SunPirvvei Co'poi r. III All, arksm epic 'o(hvu . i c u 11 LIII n th. n e.al u, I , no rmce. DOC melt e50MO6 ReVC QI' u I R FOO t PRODUCT GUIDE Fxploded Product View/F O.M, Installation Instructions - �"'�'" tut Sheets - > Spee is tions - 4 a+6 �I W I CL L u Q -- o),EcoFasten Solar 11•, QulkFoot— Product Guide _ Exploded Product.View, Bill of Materialc i I ul l '.. Materials Needed for-Assembly t , � IT Item No. Description of Material/Part Quantity l 1 QulkFoot Base Plate 1 6 2 Fastener(Length to be determined) 2 I Ij i 3 QulkFoot Flashing 1 4 S 4 EPDM Washer 1 5 L-102-3"Bracket*(other options available) 1 i.. 4 6 5/16"EPDM Bonded 18.8 55 Washer 1 7 3/8"Stainless Steel Hex Nut 1 11 I j1h" p 11 4fri, Required Tools ti V 1 � r -1 877-859-3947 EcoFasten Solar All content protected under copyright.All rights reserved.10109114 1.1 E-Faslen Sell aroducts are reached by the olbWmq U S.Patents:8.151.522 32 8.153,900 B2 8.181,398 B2 8.166,713 82 8.146.299 32 8,269 914 32 8 245 454 Be 8 272.174 B2 8,225,557 B2 ^I I I ' QuikFoot— Product Guide CuC Sheets: QF-AL-Base 1 1 i it 2X 0 .33in [8.38mm] it it I � li 1i I f IJ 4 CD O W CodN So So it �Y 1 ) I J 1 .50in [38.lOmm] 3/8"16 Stud E E E o -ter QF-M : LS" QF-L : 1 .75 ��L __.__.... 1 1 . f 'I 877-859-3947 EcoFasten SolarAll content protected under copyright All rights departed 10109/14 3.1 EcoFasten Soler ptoduas ere protected by the following a S.Patents:8.151.522 82 8.153 700 52 8.IBI 39B B2 8.166 713 62 8.146 299 62 8 209 914 82 8 245454 B28 272.174 B2 8 225 557 82 is It{ 1 rtl ' v QuikFoot— Product Guide Cut Sheets QFL-812 i R.38in —[9.53mm] .032in it rt V 0.81 mm 1 f � l x 12. I00n [304.80mm] I* h � I 3.00in li IW 76.20mm] SOin 8.00in [ 12.70mm] [203.20mm] 877-859-3947 EcoFesten Solar All content protected under copyhghtAll rights bosomed 10109114 3.3 EcoFasten Solar products are protected by the following U S.Patents 8.151522 B2 B.153,700 B2 8.161,398 B2 8.166 713 B2 8.146299 B2 B,209 914 B28 245,454 82 8,272.174 B2 8,225 557 82 fl" I � r QuikFoot— Product Guide Cut Sheets: Bra cket Options SCL-101 3/8" 46 SERRATIONS I I I v AI� i R1/16" 1 7/8' 1/4" _ ETT7 3/4 6 — _�--- R.00S If ,J R.O1O 02XR,11 4 � 60.000 Q +.006 ` / _ � 3/8"_.002 -- 1/8" 0' 7/8" X 820 DETAIL is SCALE 3:1 f) _r { ' ~ 877859-3947 Ecolosten SolarAll content protected under copyright All rights reserved 10/09114 32 9 E-F-.,Solarpbards ere prob-ted by th.following U S_PBIedc 8,151.522 B28.153 700 62 8.181 998 32 9.1661 713628,146 299 82 8209.914 92 8 245 454 82 8$92,174 B28225 557 Br II �\ uikFoot— Product Guide 5 eci Fications Q P ,, 11 , 9✓il 711e t ). I I, II PART 1 —GENERAL 1.1 SUMMA3Y rTla ,u 1. 1.3 SUBMITTAL „ A. WORK INCLUDES A. Submit manufacturers written specifications. B. Base plate is 6000 series aluminum with one 1. QuikFoot base plate attachment bracket that B. Submit standard product cut sheets. PEM Type Press-in Stud 18.8 S5. attaches directly to the roof deck C Submit Installation instructions. C Fasteners to be compatible with chosen roof 2- Provide appropriate bracket and fasteners s c D. Submit product specific load test data, showing application and meet specified pull out values for the roof system- ultimate and allowable load values specific to as shown in load test data. II11 ^t B. RELATED SECTIONS the nearness specified forthe project. D. Counter flashing is.032 gauge aluminum am - B Section 07600.Flashing and Sheet Metal bossed to accept shape of stainless steel base 2 Section 07500.Roofing 7 A QUALITYASSURANCE plate 1 13 Division 1 Administrative and Procedural Installer to be experienced In the installation of 1 j Requirements specified roofing material for no less than 5 years In Z3 FINISH 4.Division 7,Thermal and Moisture Protection the area of the project. r 7 A. Bracket is mill finish aluminum .c 5 'STEM DES'RIPT!ON 15 DELIVERY/STORAGE/HANDLING B. Basetlashing-Black-kynarpainted A. COMPONENTS Inspect material upon delivery. Notify manufacturer 1- QulkPoot system consists of aluminum within 24 hours of an missing or defective items. bracket and base slate with(1)stainless steel y g PARTS- EXECUTION t 111,l ndmuai ul y,Lsl cold uif lire gmu lu unci (1)stainless steel nut (1)EPDM washer installed. 31 eYAMINAT!nN a^d,"i boded stainless slee - t . U 11 I'll l i � washer A Substrate'. Inspect structure on which brackets 1 2. Fasteners FART 2 - PRODUCTS areto be installed and venbethat it will with- A To be of metal compatible with QuAFoot stand i bracket. Z.', MANUFACTURER any additional loading that maybe incurred. B. Fasteners should be selected for compat- EcoFasten Solar® ibility with the roof deck. 289 Harrel Street,Morrisville,VT 05661 B. Notify General Contractor of any deficiencies C.Fastener strength should exceed or be (877)859-3947 before installing EcoFasten Solar brackets. was,.ecofas[ensolarcom 4 equal to that of the allowable load of the !:F C. Verify that roofing material has been installed system.See test data at ,� correctly prior to installing solar attachment tr ' 2J. MATERIALS yP g www ecofastensolar.com l I t . 3. Sealant(it required by roof manufacturer) AAttachment Bracket brackets : 4 . 60005eries Aluminum(choose one) to be roof manufacturer approved. INSTALLATION /' 3.2 Complywith 4. Aluminum counter flashing L CP-SQ Slotted q. Comply with architectural drawings and project S. Aluminum attachment bracket 2-f-111-A . engineers recommendations for location of 3 P-3 CSK f~ system Comply B. DESIGN REQUIREMENTS'. 4.SCI-101-3 instructions Manufacturer's written i Y 1. Bracket spacing to be recommended by S.I-102-3" stallabon Instruuctions for installation and layout project engineer. 6.L-102-6" 2. Install a minimum of two fasteners per 7.Z-101 t base plate. 8.Comp Slide 3. It is important to design new structures or 8.Custom €`. . assess existing structures to make sure that they can withstand retained loads. f 877-859-3947 EcoFasten SolarAll content protected under copyright.All right reserved 10/09114 41 EmPasten Solar areduch,are protected by the following 0 5.Patents:8,151.522 B2 8,151700 B2 8,181,398 B2 0.166913 B2 8.146299 22 8 209 914 82 6.245454 B2 8 272.174 B2 0,225557 B2 Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 INSTALLATION CREW OPERATING POLICY This policy applies to all PV Squared employees in Massachusetts, but is particularly directed at those involved in the installation of solar electric and other renewable energy systems (licensed electrician, learner/apprentice electrician, licensed constructor supervisor, supervised carpenter and laborer). When engaged in this work as an employee of PV Squared on a PV Squared project site, activities of PV Squared employees are covered under the General Liability Insurance maintained by the Cooperative. It is the intent of this policy to provide clarity to installation situations where the applicable codes and regulations are unclear, ambiguous, or silent. It is possible that a municipal building or electrical inspector could interpret the codes and regulations in a manner that differs from what appears here. But this policy sets out, in writing, how the cooperative interprets legal work requirements and unclear details. It is an internal consensus working model, intended to be revised and improved from time to time. As a general matter, a city's or town's Building Commissioner is charged with enforcing the State Building Code, Plumbing and Gas Code, Electrical Code and Architectural Access Code. The commissioner addresses concerns about the safety, accessibility and security of construction of homes and businesses. The commissioner also enforces zoning bylaws. In accordance with Massachusetts General Law, employees of the cooperative who perform electrical tasks and activities must hold a Massachusetts journeymen's electrician license or be under the direct supervision of such licensed personnel. These tasks and activities include installing electrical wiring, conduits, apparatus, devices, fixtures or other appliances for carrying or using the electricity associated with Renewable Energy Generators (electrically active solar photovoltaic modules, wind turbine-generators, hydroelectric generators, etc.). In no circumstances shall the Massachusetts licensed journeymen have more than one learner or apprentice working with him/her or under his/her supervision. Mounting structures come in a variety of configurations and have differing functional and physical characteristics. A structural component or assembly becomes associated with electrical work as the Renewable Energy Generator is electrically bonded to the mounting structure. Unless otherwise noted in M.G.L. c.143 S§3 through 5560 inclusive, all structural work defined as follows shall not be required to be performed by a Massachusetts licensed journeymen electrician: • Structural improvements • Elements of a Renewable Energy Generator's support structure that fall under a building permit (e.g., assembly of top-of-pole mounting structure on steel pole with concrete foundation prior to execution of any required electrical bonding of the support structure and associated renewable energy generator (solar electric module) to the support structure Policy # 9 Installation Crew Operating Policy Pioneer Valley F'hotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by I.he Board of Directors on April 28, 2011 • Roof-top mounting support structures including but not limited to posts, stand-offs, flashings, feet, and mounting rails • Operation of heavy equipment involved in moving, hoisting, digging and other tasks • Earth work, excavation and concrete work • Manual labor involved in moving loading and unloading of equipment • Moving, hoisting, and attaching a electrically bonded panel assembly (defined as one or more assembled and electrically bonded solar electric modules) to an existing structural support designed to host the panel assembly. Note however that construction of a panel assembly is an electrical task due to the required electrical bonding activities. Repair and Servicing of Installed Equipment Repair or replacement of an electrically bonded and/or energized renewable energy generator (e.g., installed solar electric panel) will be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician. Replacement of an installed inverter must be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician, if the work requires removal of AC and/or DC conduit and associated wiring that originates outside of the installed inverter (e.g., removal of external AC conduit and wiring between the inverter and point of interconnection with the on-site electrical service). Note that this activity may require a wiring permit in scme local jurisdictions. This requirement also applies to the servicing of an installed inverter that involves replacement or repair of components and wiring internal to the pre-manufacturer inverter (i.e., factory installed components that were originally shipped with the inverter) even though such activity may not require a wiring permit. Replacement of an installed inverter may also be performed by a qualified technician who may or may not be a licensed electrician or properly supervised learner or apprentice working with a Licensed electrician if the inverter is of a "plug and play" design. Such a qualified technician can also performed other tasks that include installation and servicing inverter-based performance monitoring systems (e.g., replacing internal communication cards, making "plug and play" ethernet connections, etc.), assuming these activities do not require creation of a new AC power source circuit to operate the communication system(s). Policy # 9 Installation Crew Operating Policy Non Electrical Work at a typical PV Squared installation: • All Material Handling tasks o Module prep and moving I Ladder lift set up o Ladder set up o Trash/recycling removal and sorting • Structural Improvements o All carpentry work • Roof Mount Array o Fall protection anchor setup and removal o Layout and mounting bases o Racking up to but not including"bonding/grounding related activities" I Leveling of racking I Sealing seams/patching roofing/additional flashing • Ground mount array I Site work,earth moving o Trenching/digging o Construction of racking up to but not including "bonding/grounding related activities" • Conduit run o Making holes in structure o Fire blocking,sealing penetrations o Stickers • Power Board o Build wall, hang plywood o Stickers • Interconnection o Stickers • Monitoring o Wif options o Any"plug and play"devices o Programming of monitoring devices o Computer based activities • Installation completion I Final building inspections o Install pictures-See checklist o Update one line and roof drawings to reflect as built o Completion checklist o Notes for others o COC left onsite • Misc o Truck Organizing I Material List,ordering o Daily check-in 0 Customer interaction and training activities 5�U4 � A� Q�G PVSquaredSolar) IF=413-772-8668 Phone:413-772-8788 IF=413-771-8668 311 Wells St,Ste.B j Greenfield,MA 01301 4++., , ,o + MA Elec.L(c A13764 j MA HIC 140077 Dear Town Inspections Officials, Please see our enclosed applications to permit a Solar Photovoltaic System in your jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp, employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our Greenfield, MA Headquarters since 2002. PV Squared is committed to complying with all Commonwealth laws and regulations. Our worksite guidelines are created with the intention of exceeding all safety, electrical, and building requirements as defined by their respective jurisdictional entities. This includes the work of people from multiple disciplines, including electrical engineering, structural engineering, civil engineering, electricians, construction supervisors, roofers, and their associated helpers. We are a company that values training and education.We make certain that every individual is qualified for the roles and responsibilities that they assume. It is our policy to pay for the employees travel and training time and cost of the education, including CSL and Journeyman and Master Electrician classes. As an electrical contractor we are furthermore guided by the January 30, 2009 Massachusetts Board of State Examiners of Electricians(BSEE)judgements, and rulings that have followed.We pay strict adherence to these mandates and all electrical work is conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also understand that non-electrical tasks associated with a Solar installation can be completed by non-electrical workers, such as CSLs and others. I have attached our installation policy for your review, as well as a list of example non-electrical tasks. Should you have any questions or concerns regarding this policy or delineation of work, please let us know. We are a learning organization that is always trying to improve on what we do. Respectfully, Adam Thurrell Operations Manager b