Loading...
31C-059 HERS 15 HIGGINS-2 Air Leakage Property Organization HERS 15 Higgins Way Power House Energy Consulting Confirmed Northampton, MA 01060 413-230-3043 2017-10-30 David Gagne Rating No:HERS-961 Weather:Chicopee,MA Rater ID:7013322 HERS-961 15 Higgins Way Builder registered.blg Pecoy Companies Whole House Infiltration Blower boor Test HeatingCooling Natural ACH 0.10 0.08 ACH @ 50 Pascals 1.79 1.79 CFM @ 25 Pascals 310' 310 CFM @ 50 Pascals 486 486' Eff. Leakage Area (sq.in) 26.7 2fi.7 Specific Leakage Area 0.00014 0.00014 ELA/100 sf shell (sq.in) 0.63 0.63 CFM50/sf shell 0.12: 0.12. Duct Leakage Leakage to Outside Units CFM @ 25 Pascals CFM25 / CFMfan CFM25 / CFA CFM per Std152 CFM per Std 152 / CFA CFM @ 50 Pascals Eff. Leakage Area (sq.in) Thermal Efficiency Total Duct Leakage Units Total Duct Leakage Ventilation Mechanical Balanced. ASHRAE' ASHRAE Sensible Recovery Eff. (%) 63.0 62.2-2010 62.2-2013 Total Recovery Eff. (%) 0.0 Rate(cfm) 52 36 47 Hours/Day 24.0 24.0 24.0 Fan Watts 55.0 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the whole-building requirement under that version of the standard. Both values incorporate any appropriateinfiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate- Residential Energy Analysis and Rating Software vl5.4.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2017 Noresco, Boulder, Colorado.