Loading...
21-009 (3) 485 SYLVESTER RD BP-2017-1429 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:21 -009 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2017-1429 Project# JS-2017-002373 Est.Cost:$34000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 110253 Lot Size(sq.ft.): 1067220.00 Owner: MYERS ROBERT&DIANE DROESCHER Zoning: Applicant: SOLARCITY CORP AT: 485 SYLVESTER RD Applicant Address: Phone: Insurance: 604 SILVER ST (978)215-2369 0 Workers Compensation AGAWAMMA01001 ISSUED ON:6/7/2017 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL SOLAR ELECTRIC PANELS TO ROOF - 7.475KW- 23 PANELS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House ft Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occu.anc Si•nature: FeeTene: Date Paid: Amount: Building 6/7/2017 0:00:00 $75.00 212 Main Street,Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck-Building Commissioner File 4 BP-2017-1429 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM (978)215-2369 Q PROPERTY LOCATION 485 SYLVESTER RD MAP 21 PARCEL 009 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APSs...IN CHECKLIST OSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Wee Building Permit Filled out Fee Paid T •eof Construction: INSTALL SOLAR LECTRIC ' NELS TO ROOF-7.475KW-23 PANELS New Construction — Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 110253 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Pennits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management D-1 oli ' nn I-laaJ '{/y 7 Signature of Building Rfictal Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. Department use only City of Northampton Staves of Permit -, Building Department Curb Cut/Driveway Permit tom• • ' 212 Main Street Sewer/Septic Availability Room 100 Watermell Availability JUN - 6 I Northampton, MA 01060 Two Sets of Structural Plans phone$13-587-1240 Fax 413-587-1272 PlotSite Plans Other Spedfy APPLICATION TOCONSTRUCT,ALTER, REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address. This section to be completed by office 485 Sylvester Rd Map ,Z/ Lot Uv? unit Zone Overlay District Elm St District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Diane Droescher 485 Sylvester Rd, Name(Print) CurrentMailing Address: (413)275-2230 7 t P NE -1-D(?. ESC. NK` Telephone Signature 2.2 Authorized Agent: SolarCity Corp/James DiPadua 604 Silver St Agawam MA 01001 .me -rint) ID Current Mailing Address'. 978-847-7170 Signalu - Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS I Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 10,000 (a)Building Permit Fee 2. Electrical 24,000 (b)Estimated Total Cost of Construction from(6) 3 Plumbing Building Permit Fee • 4 Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) 34,000 Check Number 7(4 IS $75 This Section For Official Use Only Building Permit Number: Date Isaued. Signature: Building Commissionerllnspector of Buildings Date AA-1r Section 4. ZONING Alt Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be fined in by Building Department Lot Size Frontage Setbacks Front Side L. R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg&paved parking) u of Parking Spaces Fill: (volume&Iucaiion) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DONT KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DONT KNOW YES IF YES: enter Book Page and/or Document tt B. Does the site contain a brook, body of water or wetlands? NO DONT KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over I acre or is it part of a common plan that will disturb over 1 acre') YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding I I Otheri Brief Description of Proposed Work: Install solar electric panels to roof of existine home to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet sa. If New house and or addition to existing housing, complete the following. a Use of building :One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Diane Droescher as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. law Cb&ca e5 Cvxr- 6/5/17 Signature of Owner Date I, SOLARCITY CORP/James DiPadua ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORP/James DiPadua Pri a e ) 6/5/17 Signature Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable 0 Name of License Bolder:SOLARCITY/Dan Kelley 110253 License Number 604 SILVER ST AGAWAM MA 01001 12/01/19 Expiration Date 774-364-3145 Signature - Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ SOLARCITY CORP/James DiPadua 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2019 A 7 Expiration Date Telephone 978-847-7170 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.C. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ❑ No ❑ 11. - Home Owner Exemption The current exemption for"homeowners'was extended to include Owner-occupied Dwellings of one(I) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780. Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A Berson who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature. _ _ 1 tt Pal Cborman adll reNasocattlir ` Dratmef elnil i golAce/�ts f Ora M , • J f3alraa*pad AMitrD -7.7; r7-7:"7: - ` d*r.n,1L4 81141117 rmmawniNint i Naulo re C oStZmatjrn rounumeAtarrit.DiforialiCagiromieregluttrithosiebmktie Nemo lassietlatistilatilrbodp SctarClly Corp, ....____ kith= 3055 Clea Pew Way San M/io CA WWI AMA 75-2198 An pelaaplpa1 CA *lb 7 MhSML T�apyalp�.a,rl: L�ma ea/pr en 5Yaa 4.plamnia!= oia adI 19. Ono rowmrub. wael.4Meedcr ....,?K. lane NSW ,rminwmetea 20 3o adalapYrorFuton bsib main anima rim obrrhaa mentle * (Asda!¢ Tally tint mg*. 1002b/laSSW Ma9. Obrillely skid= ' r Mune* d,1 3:0 Wawa wpm*.dl hIa arlyd twos files L�lag thaws deg MSc* gramshaarmdwi tail ILO Cjly nralnerM1I= @a6 Qrm waive sew Astdwanpam pa Ida tIntatenpaba *twirl laa0147t a 133.07(4),and wit love a a 8v1ar/PV =Ors Rio'wad awara D a.hmsaapp ra9aM1 I .. ewe agadydban lis. n4iafar. .YaaeYw,.O�ua*tlran awMel wiska . ' a. m~b lalaooatreamar.tl+�.. Siam *bp'sen-aaaaaaMuwwA�W1w rm<m spar Oaptwat weft a0Arleta labPMMasao eei/alaN rla*w+nmr ban*ply lbw Zurich American I nWranze Contanw tail orMita Lc.A WC0182015CYI Ff�lowrAw9112017 1 T1 a4t N 4 enp-r .r3 Jab S9rMom.`A SA``I k.S�CL R.-0 crow *c J1a e1 Mite NQllivwian'ma4allidila PMe abardlw pie Obawitr aParar.air ul r$mlndr.y Jarman aim aaoaF awls/itidorScia 33A SI p LA m lar a la daalrradodabd padrma of dug at. !MOJA IlinclielW talal- a SU IS Avg poodle is yam gra STOP'KM etarA SA a*Yn alpdi 97-SO4byapleana4v. lahfvd/aa copy oil*ilaaoyas b Soo n a a aka or .. ren issisttie A*A Warm aawy row set ib lu$f ampArmaWaan/tr viler MAn... .paISIlwrdle ad=met >roan- 4fMrmaalit Dpanraur Salm*p.&o✓gia#Map arapa a'd mine low P aewWmuaI .Mal WagrWrbe. 4.,Odor 'Ora 2F!r}eraalu0amt 4 ciP7wra rJpe 4.Nast:at hpanr L P ibW1n C..Mt eral��� Pita.h. • • CERTIFICATE OF LIABI!ATY INSURANCE ( °"""unownw' gAwade THIS DERSACATE IS ESSUED AS AMITER CP BWORMoA ONLY MO CONFERS 110 RIGHTS EPOS TEE CEmF1CATF HOLDER..THIS CERMSFEGITE ECHE HuT AFFI RBA11MT OR NEGATIVELY Mte1D.E%SERE OR ALTER The oovp.N4GE Ahtouo BY THE POLICIES MEOW, HO G£RTR3CATE DY IHSDMNCE DOES WT CopiEra USE A CCNTRACF AETWEEN THE IBSEN2 MSIR ER(S7,AirnionDEO EEPRB (FATIVEpR piORIOERASpTNECERi1PIATE HOLDEIL m AMM II erne* s.=.. A4, :...«..... tF tiRED,'- ^.3'^.._ mast So"On , IS •:-il "i.., it ,.PIM 1134ea"4 EMR In,u MdoeafRMne tthapatv/,aattaionaltAfos may melte auerafottwarit AaditmMtail iusmdff to dwerag ma&rrlghtrIsms ceDiDeds11ildW'A Yb.WSpdLMEatonta,W. .t� _ a1140034WOMS(MUtVri v I sr OH 6116Ei� plWri *.646 aWRA'fiRxa.(A OAK AmaMMaW SAA13,1Ma voursitimoA,NNA•noun4 _u 09123VJ111DAA IEt6ll nP41nReA:2vimAVOaatAimAk Ten ' SAI WPM* Aswan:Ha NO M6E9:154ktfN 'Siang HR tWWka.G Wry mavatio,Aeemn2mUlmm-SDmPm/ �m42 INaY9ftat OtLa.h: tn.1,-GATE . ";ri..4 aAMNEtslg ES .,eN JlWID�d ' THIS IS TO CERTIFY MM1TTHE IWpUEE OF INaMMME AIRED(MOW l'iJE SEM$$UEO TO THB iflarectlAWO NONE KM THE POW(PERIOD S10100t0. NOIWMS1AOWHI MY afeliT.TERM Oft Laid' TgE1 or my pyfiMCT OR OA€$a UaSt YEN AZSPECr TO MPS TIMI L'LM'EECAW MAY BE NAKED DR MAY?ERFNR TNA RAUANCE AFFOIOXD at 11E Kt LIES oestw&fl H6EK4 SORitT TO NL 114 TeWE ENCLUSION$AMJ (MUnu.,tWSICN POURER OMDSSHOWm MAYHAYE BEES RutUOSDBYPNO OWLVS. ti#4'4YOWtlS .,� .v ms.,.�., '. u.“- ,1,..1.4.i tank A A MMmut ERMAI Ln W ka{t201a . VS" fags s Lm1At 1CNASAtV@'A�Nxng • �CtNaTO�N(M '6 IRON %'SitbatS '4208044.4ap=1.4 's UM nERsmtss AsnvMM1 1 s 100DE, ONM1MtxnGN[ImmµrylgLPEp. QmkkLeagatASR rP LOWS N Pact i' . UK - • iWbRr5:4MT1Am`a 2GYaW . a A wmwMauriastc • DnvNMN.nf MOM/0 10100117 leintr* - 'e 1.00010 • • .xWOAMVq� : - #pv'MWaPSw®W .e t'2 8A X IMA :p teatnaneMs. c ttS 'k•WYAAINOs .1U a I ` :P>tZ4gII s WN1ata NV �dx'th ~— • iDdvIXLWnGR ' F1W sI_n eNM.r+u 'i MwmnSm I o . es .yN2�.s .. 's ptNWroae N*wIioga - nrRN-ir?_ qui ^. Va,I.i2 TGA, m4 I tft llrf 0 ;Ap}.Acia� •a aMeAur11K in. ' Am •°91311211M SJY4WN ...it VCENS4Wrt e 1 iffiJANa A � iW3td6@1&U{tt¢ illigMAffik417 't 4 asA5f.Wt4MCrtt,t 1.0101 5 inF twamSdnv • Oils M4Yeueawi`-m.arat �Tes lMum.... Lpppgp • trauftiroicrarratAnosnocomestiratottiNniiii.NewgNwk9tiatay6R$tatnn spot 4..V.btJ ' —^ GERTIFICATSHOIBgjt CANCELLATION . Sm*004ahn WOUIUANY YEME 11WYe mama KO=m CANCEL4gD WPWl: ' a®CwIMaNB 1NL LEPIONDM DM THIS NQU* SRI. RE naLt.MEO W . SelliDoo,C4 WM AMWADNtRwinstsEAUtisYMOYat010. YrNorlae4mAEfMTYm vtNMzrkkomrntaswniw SNPMm2 Dimling 16:04:4w d..n:+. •Ti803054 ACOHDCORK ATIQD.AN Matt teflt. A(M]RU 2$I21114w5) The ADDED name and hen ere mg(etsmd matksofACORD `.lassachusetts Department o' ?.r:r-.c Safety I ® Board of Bu.. ding Regulations and Standards License CS-110253 Construct Li DANIEL KELLEY 11 ROLLING WOODS ROAD HUBBARDSTON MA 01462 -' ...�/� _ 1.__ X' :ra4101- Ct-.?' '11 SW el 12/01/2019 - 7/ Y- ;... ..,,.. °Mee el Consumer Wan&ermines Regubtian HOME IMPROVEMENT CONTRACTOR Registration valid for Individual use only TYPE Suodernea Card before the a rsti ion date. a found realm to:R EalratWo Ma of Consumer Affairs erd easiness Regulation 188512 03472019 10 Park Plaza-Suite 5170 SOLAR CITY CORPORATION Boston,MA 02116 DANIEL KELLEY 9055 CLEARVIEW WAY L y - SAN MATEO,CA 94402 Undelfiregry N d without signature w IIs' r /se net /NCrt'/f/// F/ r=(t,a irete{l1Gif'/ J Office of Consumer Affairs and Business Regulation 10 Park Plaza- Suite 5170 Boston, Massachusetts 02116 Home improvement Contractor Registration Type: Supplement Card ReOstr SOLAR CtTYCORPORA11ON ai ' 24 ST MARTIN STREET BID PUNK 11 Expiration: 03168572 /07(I0712018 MARLBOROUGH,MA 01752 +, n Update Address end return earn. Mark reason for change. f'I nrn:=.1 "EmpIJ4nteSt fTlwstr.3rd .:it;'., MemMemof CoasIJ retake&BvgreesRngnaenn _. RbMEINPROVEAIENT CbNTRACTbR Registration valid for individual use only 4F TYPE:Supplement Gerd before the aaplradon date If found return lo: Yby Realslrllgg EIERE119 Orem of Consumer Athra and Business Regulation 196512 03/012019 10 Park Mina-suits 5170 SOLAR ORYGORPORATION Bpshar,MA 03115 JAMES OIPAOUAQ, ,... .72/1- 3085 CWAY SAN MATEO,ATEO,CA 94402 / Not valid without signature DocuSign Envelope ID:514D460E-AOA2-4DOB-BBFO-A92F9EF85FE7 SolarCity Purchase i bd Vp'_ ng0�fl Customer Name and Address Installation Location Date Diane Droescher 485 Sylvester Rd 6/1/2017 Bob Myers Northampton,MA 01062 485 Sylvester Rd Northampton,MA 01062 Name on Unto Bill Diane Droescher The Solar Home Improvement Agreement between SolarCity Corporation DBA Tesla Energy and You,(the"Agreement")including the Exhibits to that Agreement,are hereby amended as follows: 1. Key Terms and Conditions.Section 1 of the Solar Home Improvement Agreement(the"Agreement"),"Description of the Project and Description of the Significant Materials to be Used and Equipment to be Installed"is replaced in its entirety with the following: Sale and installation of a 7.475 kW DC photovoltaic system consisting of PV modules,corresponding inverter(s)and a mounting system designed for installation and operation at your Home. 2. Key Terms and Conditions,Section 2 of the Agreement,"Contract Price"is replaced in its entirety with the following: The Contract Price for this Project is$33,114.25. The Contract Price is subject to any change orders agreed to in writing by both parties. 3. The following is added to General Terms and Conditions,Section 2.When a change order affects the amount of money to be paid under the Agreement,the timing of the progress payment schedule will remain the same but the amount of any payment shall be adjusted upward or downward to reflect the increase or decrease in the cost of the work to be performed under the Agreement and the completion percentage of any new work to be performed under this Change Order.Key Terms and Conditions,Section 4 of the Agreement,Schedule of Payments,is replaced in its entirety with the following PAYMENT TIMING AMOUNT NOTES Due at Contract $0.00 Deposit Signing Payment 1 Due When Installation $20,870.20 Begins Payment 2 Due Upon Completion $5,217.55 of Install Final REC Value $7,026.50 Payment Final Rebate Value $0.00 Payment 3055 Clearview Way,San Mateo,CA 94402 I 888.765.2489 ) solarcity.com Solar Home Improvement Agreement(Solarloan)Change Order.version 2 2 4.April a,7017 SolarCity Corporation DBA Tesla Energy Contractor License MA HIC 16a572/EL-1136MF Document generated on 5/25/7017 2724644 0 r� 0 DocuSgn Envelope ID:514D4B0E-AOA2-4DOB-BBFO-A92F9EFB5FE7 The pricing in this Solar Home Improvement Agreement Change Order is valid for 30 days after 5/25/2017. If you don't sign this Solar Home Improvement Agreement Change Order and return it to us on or prior to 30 days after 5/25/2017,SolarCity reserves the right to reject this Solar Home Improvement Agreement Change Order unless you agree to our then current pricing. This Change Order shall be incorporated into the Agreement and shall become part of the Agreement only if it is in writing and signed by the parties prior to the commencement of any work covers by this Change Order. This Change Order supersedes any prior change order. Customer's Nam: a eDproescher Solar Home Improvement Agreement Signature: ViaMA' VretSal 3" r SolarCity Date: 6/1/201 approved a Customers • huffs Signature: Signature: btu ' u Lyndon Rive, CEO 9032u?03324Ct Date: 6/2/2017 Date: 5/25/2017 Solar Home Improvement Agreement Isolarloanl Change Order,versio=n z z 4.April 4 2017 SolarCty CorpoaCon DBA Tesla Energy Contractor License MA HIC 16852/EL-1135MR ❑2t EI 7724544 SolarCity Version#67.5-TBD May 24,2017 RE: CERTIFICATION LETTER Project/Job#0102710 AT" OF MgSs Project Address: Droescher Residence 1�" 40 485 Sylvester Rdla. yG HUSSEIN A. Northampton, MA 01062 y KAZAN AFD Northampton - - C1111L — w SC Office Springfield 'O� '�No. 52612 42- Design Criteria: "O, IQ/ Teat- AQ-Applicable Codes = MA Res.Code, 8th Edition,ASCE 7-05,and 2005 NDS CSS/�pL -Risk Category= II -Wind Speed = 90 mph, Exposure Category C, Partially/Fully Enclosed Method -Ground Snow Load = 90 psf - MP1: 2x6 @ 16"OC,Roof DL = 10 psf, Roof LL/SL= 28 psf(Non-PV), Roof LL/SL= 28 psf(PV) - MP2: 2x6 @ 16"OC, Roof DL = 10 psf, Roof LL/SL= 28 psf(Non-PV),Roof LL/SL= 28 psf(PV) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22424 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Hussein A. Kazan, P.E. Hussein Digitally signed by Professional Engineer Hussein kazan T: 609.642.9016 kazan Date:2017.05.25 07:45:19 email: hkazan@solarcity.com -04'00' • Version#67.5-TBD SolarCity HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1 64" 29" 39" NA Staggered 35.2% MP2 64" 24" 39" NA Staggered 35.2% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift OCR MPI 48" 17' 65" NA Staggered 99.1% MP2 48" 17" 65" NA Staggered 49.1% Strecture Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MP1 Stick Frame 16"O.C. 25° __ Member Analysis OK MP2 Slick Frame 16"O.C. 25° Member Analysis OK_ Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1 Member Properties Summary MPS Horizontal Member Spans Rafter Properties Overhang 0.16 ft Actual W ! 1.50" Roof System Properties Span 1 9.93 ft Actual 0 Number of Spans(w/o Overhang) 1 Span 2 Nominal Yes Roofing Natural Comp Roof 303113 A(in^2) 8.25 Re-Roof Yes Span4 Sx(in.^3) 7.56 Plywood Sheathing -- Yes Span 5 Ix(in^4) 20.80 Board Sheathing None Total Rake Span 11.13 ft TL DefI'n Limit 120 Vaulted Ceiling No PV 1 Start 0.75 ft Wood Specks SPF Ceiling Finish 1/2"Gypsum Board PY 1 End 8.83 ft Wood Grade tr2 Rafter Slope 25° PV 2 Start Fb(Psi) 875 Rafter Spacing 16"O.C. PV 2 End ..� Ey(psi) 135 Top Lat Bradng ..... Full PV 3 Start E(psi) 1,900,000 Sot tat Bracing At Supports PY 3 End E-min(psi) 510,000 Member Loading Summary Roof Pitch l 6/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load l DL 10.0 psf x 1.10 11.0 psf 11.0 psf PV Dead Load PV-DL 3.0 psf x 1.10 33 psf Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load LL/SLL2 40.0 psf x 0.7 I x 0.7 28.0 psf 28.0 psf Total Load(Governing LC) TL 39.0 psf pg Notes: 1. ps=Cs*pf,Cs roof,Cs-pv per ASCE 7[Rgure 7-2] 2. pf=0.7(Ce)(C,)(1,) ; CQ 0.9,G=1.1,15=1.0 42,3 psf Member Analysis Results Summary Governing Analysis Max Moment 0 Location Capacity f DCR Result (+)Bending Stress(psi) 1,100.6 5.1 ft , 1,504.3 730/a Pass ZEP HARDWARE DESIGN CALCULATIONS- MP1 Mounting Plane Information Roofing Material Comp Roof Roof Slope 25° Rafter Spadng 16"O.C. Framing Type/Direction Y-Y Rafters PV System Type SolarCity SleekMountt" Zep System Type ZS Comp , Standoff(Attachment Hardware) Camp Mount Tvoe C Spanning Vents No Wind Design Criteria Design Code IBC 2009 I ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Hg.6-118/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure I IC, 0.95 Table 6-3 Topographic Factor Ka 1.00 Section 6.5.7 Wind Directionality Factor Fr 0.85 Table 6-4 Importance Factor ___ 1 1.0 Table 6-1 Velocity Pressure qh qh= 0.00256(Kz)(Kzt)(Kd)(VA2)(I) Equation 6-15 16.7 psf Wind Pressure Ext. Pressure Coefficient(Up) GCp(Up) 1 -0.88 Fig.6-11B/C/D-14N5 Ext.Pressure Coefficient(Down) GCp(Down), 0.45 Hg.6-11B/C/D-14AB Design Wind Pressure p _ • p=qh (GCp) 6uation 6-22 Wind Pressure Up Pmol __ -14.6 psf Wind Pressure Down Pra°wm 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 69" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -225 lbs Uplift Capacity of Standoff T-allow 637 lbs Standoff Demand/Capacity DCR 35.2% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration I Portrait Staggered Max Standoff Tributary Area Trib 22 sf T PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -281 lbs Uplift Capacity of Standoff T-allow 637 lbs Standoff Demand/Capacity OCR I 44.1% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP2 Member Properties Summary MP2 Horizontal Member Spans Rafter Properties Overhang 0.16 ft ActualW 1 1.50" Roof System Prop t Span 1 10.00 ft Actual D 5.50" Number of Spans(w/o Overhang) 1 Span 2 Nominal Yes Roofilm Material_. Comp Roof 5pnn3 A(in^2) 8.25 Re-Roof Yes Span 4 Sx(in.9) 7.56 Plywood Sheathing _ Yes Span 5 Ix(in^4) 20.80 Board Sheathing None Total Rake Span 11.21 ft TL Def'n Limit 120 Vaulted Ceiling No PV 1 Start 333 ft Wood Species WE Ceiling Finish U2"Gypsum Board PY 1 End 9.42 ft Wood Grade a2 Rafter Slope 25° PV 2 Start fb(psi) 875 Rafter Spacing - 16"O.C. PV End Fs(psi) 135 Top Let Bracing Full PV 3 Start E(psi) 1,400,000 Sot Let Bracing At Supports EV 3 End E-minin(psi) 5710,,000 Member Loading Summary Roof Pitch 6/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.0 psf x 1.10 11.0 psf 11.0 psf PY Dead Load PV-DL 3.0 psf x 1.10 3_3 psf Roof lie Load RLL 20.0 psi x 0.93 18.5 psf Live/Snow Load LL/Stas 40.0 psf x 0.7 I x 0.7 28.0 psf 28.0 psf Total Load(Governing LC) TL 39.0 psf 42.3 psf Notes: 1. ps=Cs'pf;Cs-roof,Cs-pv per ASCE 7[F9ure 7-2] 2. pf=0.7(CO(CO(1F)pg; CQ=0.9,Q=1.1,h1.0 Member Analysis Results Summary Governing Analysis Max Moment @ Location Capacity DCR Result (+)Bending Stress(psi) 1,100.6 5.2 ft 1,504.3 73% Pass ZEP HARDWARE DESIGN CALCULATIONS - MP2 Mounting Plane Information Roofing Material Comp Roof Roof Slope 25° Rafter Spacing 16"O.C. Framing Type/Direction Y-Y Rafters PV System Type SolarCity SleekMounC" Zep System Type ZS Comp Standoff(Attachment Hardware) Como Mount Type C Spanning Vents No Wind Design Criteria Design Code IBC 2009 ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed ' V 90 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-118/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure K, 0.95 Table 6-3 Topographic Factor K,r 1.00 Section 6.5.7 Wind Directionality Factor Ka 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qa- qh = 0.00256(Kz)(Kpzt)sf (Kd)(V^2)(I) Equation 6-15 Wind Pressure Ext. Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-118/C/D-14A/B Ext. Pressure Coefficient(Down) GCp(Down) 0.45 - Fig.6-11B/C/D-14N6 Design Wind Pressure I pp =qh (GCp) Equation 6-22 Wind Pressure Up Pow _ — _ -14.6 psf Wind Pressure Down Pmo.m 10.0 psf ALLOWABLE STANDOFF SPACINGS it-Direction V-Direction Max Allowable Standoff Spacing Landscape 64 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -225 lbs Uplift Capacity of Standoff 7-allow 637 lbs Standoff Demand/Capacity DCR 35.2% X-Direction V-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration i Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -281 lbs Uplift Capacity of Standoff i T-allow 637 lbs Standoff Demand/Capacity I DCR 44.1% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERRED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS ND BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONAI.LY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHAD. UST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE MTH ART. 110.3. (E) EXISTING 4. *ERE All TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TURING MEANS MAY BE ENERGIZED IN THE OPEN POSRON, F58 FIRE SET-BACK _A SIGN OPLL BE PROVIDED WARNING OF THE T y ^?THAMPTON GALV GALVANIZED HAZARDS PER ART. 690.'1. CC 'IIII 1 CF :;e1: T GEC CRWNDING ELECTRODE CONDUCTOR 5, EACH UNGROUNDED CONDUCTOR OF THE UUILIviI\ .: ".li 1 HENT GND GROUND MULTIWRE BRANCH CIRCUIT WILL BE IDENTIFIED BY "- HOG HOE DIPPED GALVANIZED PHASE MD SYSTEM PER ART. 210.5. L. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WDI ART. 250.91. 250.92(B). These plans haus yy r� YiC: led Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER Y kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR And approved. kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE OC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART 690.51(E). 1401 MINIMUM 8. ALL WIRES SHALL BE PROVrDED WTH STRAIN d— 7- /7 (N) NEW RELIEF AT ALL ENTR+ INTO BOXES AS REQUIRED BY Date NEUT NEUTRAL UL LISTING, Z NIS NOT TO SCALE 9. MODULE FRAMES SHALL 8E GROUNDED AT THE / OC ON CENTER UL-LISTED LOCATION FRONDED BY THE - / - - I1- PL PROPERTY UKMANUFACTURER USING UL LISTED GROUNDING Signature " PO POINT OF iN TERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10, MODULE FRAMES, RAIL, ANO POSTS SHALL HE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS, 5 STAINLESS STEEL - SIC STANDARD TESTING CONDITIONS DP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V v0.T I ......"_- Ymp V TAGS AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINRCHT PVT COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL NEWS PY4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM PV7 PROPERTY PLAN GEN 4168572 1. ALL WORK 10 BE DONE 10 THE BTH EDITION Cutsheels Attached HEC H36 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY PITH THE 2017 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEF SOLAR silVP REV BY DATE COMMENTS Nort!amDton ,Q�� REV P. MAKortre I COMY1NIS UTILITY: Notional Grid USA (Massachusetts Electric) Google �� , .-._. .. i . . r Lei _ 1 `1 '.° .-)'.. ClgAL- TELE N6AlArIC"W" awan: JB-01©2710 00 „c.a.. . o .r, �('� c<NTNNED Siva Nor EC an FOR ne ... .__— DIANE DROESCHER Diane Droescher RESIDENCE Cesar Returner(' �' nc^'�r/�''}`` [Of fit a xmu uo-rl saxnn EIC. C rnp �- ''+,A ` l.y 1 Nal grana°ISMS°N awn CR IN IS Comp V4 w Metal-FTasnin4�. 485 SYLVESTER RD 7.475 KW PV ARRAY , Pon N I1 E NRVi nt'Ewers -.-___-- elMANIZAICN,DWEPTNetlMCCMNnm I(23) NORTHAMPTON, MA 01062 5a O1 .NR ux a NI NL'fllnSC (23) SoiecCity Standard ((SC725 14 St wtn Plw,ewsw z um n 710140P'EICIAN P'T. WOK PS IIMM/I loma vki NAY' SHELF R[\ 11.7£: u 1F: T (�INlo ,t.MA1roP)erilo35 PomssiaN a s<uaarc OR. Multiple Inverters COVER SHEET PV 1 5%24/2017 temL-Six-an NrLlml ••..107011" PITCH: 25 ARRAY PITCH:25 MPI AZIMUTH:268 ARRAY AZIMUTH:268 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 25 ARRAY PITCH:25 MP2 AZIMUTH:88 ARRAY AZIMUTH:88 MATERIAL:Comp Shingle STORY: 2 Stories • PITCH:25 ARRAY PITCH:25 z MP4 AZIMUTH:265 ARRAY AZIMUTH:265 O © s`'_ m ® 0 MATERIAL:Comp Shingle STORY: 1 Story PITCH: 25 ARRAY PITCH:25 a MUM � MP5 AZIMUTH:85 ARRAY AZIMUTH:85 Mr :� EL_A MATERIAL:Comp Shingle STORY: 1 Story �� ®�® ® H U SS2I I1 kazan Digitally signed by Hussein kazan Date: 2017.05.2 5 07:46:04-04'00' ® ® LEGEND Front Of House ®® 441U Nel� 0 (E) UTILITY METER & WARNING LABEL LIQ MoINVERTER W/ INTEGRATED DC DISCO '�� a0 CO & WARNING LABELS mMa�� N. FD'-I DC DISCONNECT & WARNING LABELS ®® ,® 0 Lc AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS 7 1 -- 0 DISTRIBUTION PANEL & LABELS ��g'fN oP Mq�� LOAD CENTER & WARNING LABELS crt .T HUSSEIN A. m O DEDICATED PV SYSTEM METER O KAZAN —4 .... .- . -•»C1W{.— " 0' _ 8 RAPID SHUTDOWN I No. 52612 1$6 yE02 TE#N17. ! i STANDOFF LOCATIONS (E) DRIVEWAY -*stow.VWa- CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE 0HEAT PRODUCING VENTS ARE RED , It II INTERIOR EQUIPMENT IS DASHED 1 Lt.. SITE PLAN ' N • Scale: 3/32" = 1' w CD E 01' 10' 21' S JB-0102710 00 auMSEOMER: DESCRIPTION: . CMrMNED SHALL- 1HE T RE12USED F R IHE J[8 WJYaR: lb;SolarCity Dom OANYONE CE USED FOR TEE DIANE DROE$OHER Diane DroeSCheT RESIDENCE Cesar Palomera Dom 6 ANYONE EX PT SOIMCItt INC., MOONING SYSTEM: NOR SNAIL a 6E DISCLOSED IN rxDIE CD IN ZS Comp V4 w Metal—Flashing 485 SYLVESTER RD 7.475 KW PV ARRAY PART TO 111,OTHERS CElrswE THE RECIPIENTS rs MmuEa NORTHAMPTON, MA 01062 24 St Maw�,,,ewmDmf N NIE SkE EXCEPT x CONNECTOR MITI9 Z NE SIME MID uME Of TIE RESPE[PW (23) SolarCity Standard #SC325 �Er: Rv: DATE Marlborough.MA 01152 saanalY EQUIPMENT,Xnxoui THE w611FN N,hRhk PAGE NNE T (650)63a-lone 1: (650)638-1029 PERMISSION DE SaMatt INC. Multiple Inverters SITE PLAN PV 2 5/24/2017 (016)-sa-att(165-24re) nw.daroly. „....,,,, ,, ,,,,,,,. isliA: h HIHIHI , its/ 4.. 10'_2” 10'-2" (E) LBW 1 (E) LBW ` A) SIDE VIEW OF MP1 NTS i. SIDE VIEW OF MP2 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES �`MP2 X-SPACING X-CANTILEVER 1-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" 41" 0" STAGGERED LANDSCAPE 64" 24" 41" 0" STAGGERED PORTRAIT 48" 17" 62" 0" PORTRAIT 48" 17" 62" 0" RAFTER 2%6 @ 16" OC ROOF AZI 268 PITCH 25 STORIES: 2 RAFTER 2x6 @ 16" OC ROOF AZT 88 PITCH 25 STORIES: 2 ARRAY AZI 268 PITCH 25 ARRAY AZI 88 PITCH 25 C.]. 2x6 @16"OC Comp Shingle C.]. 2x6 @16" OC Comp Shingle X ANDY ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X ANDY ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. X IS ACROSS RAFTERS AND V IS ALONG RAFTERS. PV MODULE 5/16" BOLT WITH INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) � HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. �,SN OF Ago_ ZEP COMP MOUNT C ', a��?\rMGI1MFFFF 1MMIMFF:a:UUpUIIUlMF 3 INSERT FLASHING. �`SCNOT yC. ZEP FLASHING C 'al."Ir ( ) = o HUSSEIN A. m (E) COMP. SHINGLE S as— (4) PLACE MOUNT. KAZAN No. 52612 (E) ROOF DECKINGrall 1 INSTALL LAG BOLT WITH Ali ni yt,0" d4�R 5/16" DIA STAINLESS (5) (5) SFAI INC WASHER. Si H STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH OVALE G WTH SEALING WASHER (6) • (2-1/2" EMBED, MIN) BOLT & WASHERS. • (E) RAFTER C�S STANDOFF ) Scale: 1 1/2" - 1' PREMISE OYER: MStWllO: DEER: CONTINEllAI- METIBERUAR FHE ME ,m NUMBER J B-01 0271 0 00 DIANE DROESCHER Diane Droescher RESIDENCE Cesar Palomera �"4�Ohr�'}" BENEFIT ANYONE E EXCEPT eE S Fan mE I 1 lr aFNFfIT Gf ANYONE OOSEY1OE INC., KOOK SYSTat NW SHALL n K DISCLOSED 1 IN MOLE OR IN ZS Comp V4 w Metal-Flashing 485 SYLVESTER RD 7.475 KW PV ARRAY • ��� PART TO OTHERS OUTSIDE 1HE RECIPIENTS ORGANIZATION, MKIN CONNECTION MIH MIS: NORTHAMPTON, MA 01062 THE SUE AND USE OF ME RESPECTIS£ (23) SolarCity Standard #SC325 • 24 51 Moth Move,ally 2Unit II SCORn1T EWFIAEHT. YOHWT ME WHEN INVERTER: PAGE WE SHEET: REV DATE: Marlborough,MA 01752 PEMeISSON OF swROTY INC. Multiple InvertersSTRUCTURAL VIEWS PV 3 5/24/2017 ( r—(56aa15xam6ae Z4n9o...wo-arMdR,s , SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONNDENTAI- THE INF MATON HEREIN m"ism J B-01 0271 0 OO PREMISE ONNEA. DESCRIPTOR: DESIGN CONTAINED SHALL NOT BE USED FOR NE DIANE DROESCHER Diane Droescher RESIDENCE Cesar Palomera �c.L &NEM Of ANYONE EXCEPT SCORCH',NC, MOINDIC SRTI SolarCity. N SHALL IT BE DISCLOSED N oswxaLL OR IN zs Comp V4 w Metal—Flashing 485 SYLVESTER RD 7.475 KW PV ARRAY -PIN PART TOO ERS OUTSIDE THE RECIPIENT'S u>oulEs NORTHAMPTON, MA 01062 CNLATON.EXCEPT M CONNECTION WTI NE SALE ARD USE Of THE RESPECT* (23) SolarCity Standard #50325 24 St. Wein o,n.,BUR6e4 z Una 11 SaIIACIIY EpAFMENi, WTIWi THE WRITTEN PAW NNE MEET: RR DAT. I6j8-10 B MA 01752 PERMISSION Of ffIaaTy INC. mum: T: (650)6]8-1028 E (650)638-1029 Multiple Inverters UPLIFT CALCULATIONS PV 4 5/24/2017 0388)-SOL-CITY Q65-1489) .....NvmxRxN GROUND SPECS MAIN PANEL SPECS ' GENERAL NOTES I INVERTER SPECS MODULE SPECS LICENSE BOND (N) 08 GEC TO TWO (N) GROUND Panel Number:NoMatch v I: DC Ungrounded INV1 -Week I SAM 5.2 n LABEL a -(j3)SolarCIty Standard #SC325 GEN 8168572 3005 AT PANEL MTH IRREVERSIBLE CRIMP Meter Number:93553949 Inv 2: DC Ungrounded Proctor. 5200W,240V,91.92 Ponta 5200X,240V/208V.91.5% PLC,ZOee,RCM PV Module. 325W, 306.5 PTC, 40MM, elk Frm, MC4, 600v, ZEP, 96-C ELEC 1136 MR Overhead Service Entrance lie-In: Supply Side Connection INV 2-(1)DeIto I50 311 IL LABEL A Ylrorter:MOW, 240V, 97.5%, Zighm,PLC. ROM Vac 69,6 Vpmar 576 INV 3 Ise AND Imo ARE SHOWY N THE DC STRINGS COMER E 200A MAIN SERMCE PANEL E`) 200A 2P MAIN CIRCUIT BREAKER MULTI-CONTACT CSocket Delta ! / Branch Socket (E) WIRING BRYANT BRYANT Inverter 1 IND CUTLER-HAMMER B Load Center (N) 125A Load Center Q A 0 / I 200A/2P Disconnect ID(N) Q Delta • pc- D I Sa;ivia 5.2 IL i p MP is ix7 I _ t ( SAA/2P` E E JOA/2P mo. ---*----Sr EGc--J g N _ W __ ''tljjtp(1 111 II (E)LOADS J- - EGA - �. I © �- MP 1: 2x4 i Vil GED A t i ' L�. 10:0 7'_.'-Eos ,.j J Gc I }_ J Inverter 2 N `(1)canaax Kn: 3/4• MC a.'GEG 1, rim,{'____ @ Oetta k Salivia 3.8 TL ` 20A/2P MULTI-CONTACT Ori �- E LI ® ac -- - LE Branch Socket 9 C 3 To 120/240v _ _ SNa.E PHASE 0 I A t Dc r. L_ L_ ✓ - / Doc—{76+ MP 2: 2x4 UMW DUNCE ------------- 1- '-T� �„__� J °C� f I GAD EGL II S— PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Vocs = MAX VOC AT MIN TEMP POI---(2)aweaye, D (t)ERVANTlEN2%JO B s)cam�f Senna A _(2)Mr «HA +P Cappre ) Lead Center, RV" 120j240Y, NEMA 3R AC Sn RSS Rapti RutdOIn,BODY, 20A, NEMA 4X, MC4 Brandt Socket;1104 U-Mit cmnala, Finale Eemale Male DC -(2)6SC0/WD ilbul6 ` -(1)CURER-N1IMff,,RR 188250 Insulation Piero 9 Cocwoct r, Man 4/0-4, Ta 6-14 Bracket, /ZE`, 2 Spam C (2)Data I SoliNa -(2/MULTI-CONTACT PV-AZ54 Ir-� QL�p SmartRSS Rapid 91utdow1.6Wv,, 20W NEMA 4X X04 I_ Brunch Hug; MC4 U-JONI Vivisector.Mole Mole Timm F (IBA M TI 481 2gRliD/z4av, NEMA 3i E (I)CURER-HAMMER I Da2I2URe �- Y� ,.L (UAWG 16, Rolle Bore Capper 125A. Disconnect: 60A. 24OVac, Nan-FUSWe, NEPA St 1.JnE1 -(1)CU11ER-HANNEP 19R230 -(I)CUTTER-HAMMER f DCI00x8 -(I) -_(t) Wacker; 30A/21I, &o-awufrd M^ q1: 40-100k,Gourd Duty(LG) {N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEP110N NO. 2, AOBITICNAL k'd'^: 20Afte,2`.meoee ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCA1ON OF (E) ELECTRODE SSC-SUPPLY 9DE CONNECTION. DISCONNECTING MEANS SHALL er SIITAfE • AS SERWCE EDITTMENI AND.SHALL BE RATED PER.NEC. FT(t ANG /6. MM4-2. BaG --_ �//y,��FI�TgT)--(I)ANG/10, THMI-2.Mods --_ LT(2)AW0 PO, PV Mire. 6WV.OM" Vac' =31835 VDC Iso -12.06 AX /' NT—(2)A%G PO, PV Me. 600V, Black Vac* =553.61 VDC Is• >603 ADC ©W(1)ANG g THM4-2. Redo ed /�'L(I)Av.G IIB THMZ-2,Red O&J (I)AttU Solid eco Copper 16C VmP -230,4 VDC me-11.3 ADO l I 1 D)A%G IB, Seed BTS COPpn EGG vmp 4032 VDC imp,5,65 AUC L {t}A%G�L MYd-2,YIMte NEUTRAL Ymp =2240 VAC Irp=37.4 MC �'L(i}A% SID m$-2 Pita $EIDRft Vmp =240 VAC Ienp 2'.6 AAC CL-(llCaW i Xie 3/c ETT `l (11Gencey# it 3/4'EMT -(1)Aws 1MNi-E,Meer EGCja-(I)Ca4u KH,3/4•EMT -(I)ANO imni-,2,Gran ECC/GEC-(t)Cmd&RIF 3j4•EMT r�,-'{3}AWG(10. Pv%ke,SWV,sok YCc' =55361 VDC Iso=6.03 ADC ��IT{i)A%G I}0. PV Ate, 600N 6beX - Vac• :=3213r4 J1fi.35 VDC iso=6,0.1 ADC ©FFTT(i}AM: /6 1HM4-1,Dad- (Om/I0,RINN-1,Block © 'M*1 (I)AWG I6 SdM Bae capper ECC Vmp =4032 VDC Imp=545 ADC I / I rol-(I)ANG A.S lid Bare Copper ECC Vmp =230.4 voc Imp=5.65 ADC IYx-(1)AWG /6 1HNN-2, Red ®IRI-(I)AM:/I0, THM4-2 Red L'*1 (1)Condit Kt 3/4' EMT ��k`1 (I)CmNit Nlti 3/4' EIAs IICCLL....(1)ANC jO 1HNN-2, NLite NEUTRAL Vmp =240 VAC Imp=37.4 MC LI-(I)ANG ff10 1NVM-2, NMte NEUTRAI, Vmp 240 VAC Imp 15.8 MC (4)A%G gin. PV Mre. 600V.Bath VOC' 316.35 VDC Iso =13 W ADC ' /^ "(4)ARG 110, PV Wye. 600V, Block voc" =31635 VDC iso =6,03 ADC -(1)AM;/6 Solid Bar Capps GEC -{t)Conduit NI, 3/4'ENT _-(DANS R THW4-2, Mem EGL/GEC-(1)Conduit ND 3/C EMT _ O E)ANG P. SIN Bore Copper WC Vmp =230,4 VDC Imp-113 ADC (2)AM:/6Di4-3/ ENT 3 (1)e ra/6, Bale Bore Copper EVC Vmp 2304 VDC Imp=5.65 ADC (i}Cmduf Nd. Et terrain/Nit;NC 81i %4q Co s, EG Vmp =31603 VC ImP=11.3 ADC ®051-(1)A%G I. $alltl Bare Copper' EGG VmP '2301 VDC Imp.11.3 ADC CCCkkk (t)CmJul 5A-S(l' FYS k*�(IACcc6t Nib tf4 FIE COMMENSAL- ME INFORMATION HERRN AM RIMER: JB-0102710 OO PUDE GONER 0E506/II0N DEBq: \ UNTAMED AAD NOT BE u9m FOR THE DIANE DROESCHER Diane Droescher RESIDENCE Cesar Palomera tM45ol3CCi}l r BENEFIT 41L ANYONE Exam MANORS INC., Ywx1Ma cnp 485 SYLVESTER RDPVeta l.r 14f{ 'TBE W41C6E'I IN T."CNE DR w ZS Comp V4 w Met01-Flashing 7.4-75 KW ARRAY IN PART TO OWNS COME DYE tSGN OES ORGANIZATION,EXCEPT IN CONNECTION MTH WORMNORTHAMPTON, MA 01062 THE SALE AMID USE OF THE REWECBVE (23) SolorCity Standard #5C375 24 St Mode DM BUMPS 2,UAB 11 SMARTIES mem WITHOUT THE NRIIIEN PACE MB 9187: REV DATE MMemaup,NA 01152 PERMISSION aswPan Nc Mu ple Inverters THREE LINE DIAGRAM PV 5 5/24/2017 wee-1see-erre --2.ia9) tumid mg-ma WARNING'.PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label Location: (C)(CB) WARNING (Ac)(PGI) WARNING (DC)(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 ELECTRIC SHOCK HAZARD NEC 690.17.E ELECTRIC SHOCK HAZARD NEC 690.35 F DO NOT TOUCH TERMINALS THE DC CONDUCTORS OF THIS ( ) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND INVERTER IS PHOTOVOLTAIC DC (DC)(INV) IN THE OPEN POSITION MAY BE ENERGIZED UNGROUNDED DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PHOTOVOLTAIC SYSTEM (INV) MAXIMUM POWER- (DC) (INV) EQUIPPED WITH RAPID Per Code: POINT CURRENT(L HE) Per Per Code: SHUTDOWN CEC 690.56(C) MAXIMUM PE':WER- POINT VOLTAGE(Vmp) NEC 690.53 MAXIMUM SYSTEM VOLTAGE(VOC) SHORT-CIRCUIT CURRENT Use) A Label Location: WARNING (P01) Per Code: INVERTER OUTPUT CONNECTION NEC 690.64.B.7 Label Location: DO NOT RELOCATE DC (INV THIS OVERCURRENT WARNING DEVICE Per Code: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED CONDUCTORS MAY HE UNGROUNDED AND ENERGIZED Label Location: CAUTION (D)(P01) PHOTOVOLTAIC SYSTEM Per Code: CIRCUIT IS BACKFED NEC 690.64.64 Label Location: WARNING (DC) (CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED CAUTION (P01) IN THE OPEN POSITION DUAL POWER SOURCE Per Code: DC VOLTAGE IS SECOND SOURCE IS NEC 690.64.6.4 ALWAYS PRESENT WHEN PHOTOVOLTAIC SYSTEM SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label Location: PHOTOVOLTAIC POINT OF (P01) Label Location: INTERCONNECTION Per Code: PHOTOVOLTAIC AC (AC)(P01) WARNING ELECTRIC SHOCK NEC 690.17 4; NEC 690.54 (AC):AC Disconnect DISCONNECT Per Code: HAZARD DO NOT NALS (C(CB): Combiner Box TTHMINALS TERMINALS ON NEC 690.14.C.2 BOTH THE LINE AND LOADF SIDE MAY BE IN THE OPEN (D): Distribution Panel POSITION FOR SERVICE (DC): DC Disconnect DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. (IC): Interior Run Conduit Label Location: PV POWER SOURCE (INV): Inverter With Integrated DC Disconnect MAXIMl1M AC (AC)(P01) MAXIMUM AG (LC): Load Center OPERATING CURRENT A Per Code: OPERATING CURREM (M): Utility Meter INC VOLTAGE OPERATING VOLTAGE ( )M GE V NEC 690.54 ING OLM GE v OPERA'0POI : Point of Interconnection MA CWMENIIAL- THE ILFORMAIION HEREH COHi.WED SHALT NOT BE USED FOR =T.", 3055 Clearvie6 Way 1HE EElkm OF ANYONE EXCEPT SDIMC1tt INC.,NoR s ALT IT BE DISCLOSED 1.I i114 //\�q/�_real T:(550)5z3atOzan e EA F:Ic501 6.36-i0z9 IN WOLF OR IN PART 10 OTHERS OUTSIDE NE REtlPENTS ORGANIZATION, Label Set %l(il Jol w' ■ _' (asermLCln(765.x489)waw.36-ion corn EXCEPT M CONNECTION BATH THE SALE AND USE OF ME RESPEC11W M V SOL/LRCM(EQUIPMENT, %MOAT NE MITTEN PERMSSEN OF SOIMUIY INC. re ' y• , '" Model RSSG004-2 Connection Diagram: __ DELTA RAPID SHUTDOWNVox 1^f' „ n W. [T , y ON O Fminis1 OFPV N� a w 7i®. V�e IE1 / ° d4 ^4" �,/C gyrus d t P i / .. y �r .-JL. —;1! P 4, a 4T Ae .wra.a• � x OC PV. On•conduit BREAKER GRID __ -.- QAC kir all wiring I I Technical Specifications " . .. Ratings .J'. 2qT. . _- MaxxrtSystem ,'.'*#d Dr r ...lu'.�""bal,.. P,.t f.." h'"J f. . M .System WWI"WWI" VI600V DC fiUODC - wMax.Number Off Input Circuit 4uit 1 4 j Rated Input Current Per String 20A 10A 4,..7/ J/ '? Awsa • Fuse Rating N/A ISA / Max.Puf tubelbgr of MaNumMrof output clrcwt 1 2 \ . Game OutputCurrent Per Circuit 20A 20A / Maximum Current Controlled Conductor 25A 25A Output Terminal Wire Size 10 AWG 128AWG Output Conduit Size WA 3/4"(two holes) , Control Signal Method PLC Slgul 5V Signal Wire 5V Signal Wire Voltage Rating WA 600V --- 5V Signal Wire Size Range WA 24-14AWG General Data Rapid Shutdown Device Enclosure Size in Inches L x WED(mm) 7.87 x 591 x 2.00(AO x 107 x 53) 1244 x 1004x 2.16(316 x 255 x55) • 266I1is(1.3kg) 6SIbs(3.01G) for Delta 3. 0N7 .6 TL Inverters Input Connectors MC-4 PV Connector or A7,phend„4 PV Connector MC-4 PV Connector orAmphenol 11.4 PV Connector output Connectors C4 PV Connector orAmphena H4 PV Connector Screw Terminal Blocks Operating Temperature 40-158°F(40-70°C) 40-156°F(40-70°C) Delta's Rapid Shutdown Devices provide an automatic disconnect of 600VDC Storage temperature 40-185•F(40-85'C) 40-185"F(40-85°C) residential or small commedcial PV array system,fully compliant with the Rapid Shutdown requirements of NEC 2014 article 69012. It is compatible with Delta's a bo-100% 0-100% Max,Operating Altitude 2000m above sea level 2000m above sea level single-phase residential Inverters. al 10 Years 10 veers Standard Compliance KEY FEATURES Enclosure Protection Rating NEMA4x NEMA OX -NI-MA 4X Protection UL 1741,CSA 22.2107-1 UL 1741.OSA 22.2107-1 •Compact and Lightweight NEC Cole NEC 2014 Male 690.12 NEC 2014 Article 890.12 •Rack Mount Installation Delta Products Corporation,Inc. •Fast Connect with PV Connectors 46101 Fremont Blvd •Compliant with NEC 2014 article 69(111 Fremont,CA 94538 •PLC Communication(Model RSS-600 1-1 only) Sales Email. InverterSupport delta-rp.com Support Email: Inverter.Support©delta-corp Sales Hotline: +1-377440-5851 or $ +1-626-369-8021 Support Hotline: +1-077-4424832 Support(Intl.): +1-626-369-8019 A C US AELTI1 Monday to Friday lino Pars:tern PST{apart tom Holden)www.delta-amencas.com/solarinverlers Q AELTI1 • • Delta Solar Inverters Datasheet for SolarCity .w `uAi e.,.. P.�... v.�tdw e u "£S4 INPUT MCI .1111111111.1...ei_ ® l&OA 200n x19.Wev xo O AP Nee tusk& IIMIIIMIIIIINNINNIMAIN x5. , ���(�� ® 6000W4200µ 5wW ./ F&..i avast ® Sternal ES Sciara ACi [V ani CI • • Mall OUTPUT I11111/11...111111 Aw�w x � w4VI s 00W 2OV/ MOO V 7600W V ® n. ® Cov 5 w4OMVYv 190080 Naw ®wv ® BVMme n xu simmim strew sem ss®]mv a p®xmVs O ®ewv ® m 0 • ®Nov a ®NOv MNov ®]mv L .111/S111151101111111111 s"'-'•' i Y 1111S1111 'Is' 1111 1 ar tae <sO egosyet®im 0 , 1 . NISIIIIIIIIIMI MS adiiiirew97x519 9015%®0819 61 dvs4 tune/sclw'Gl A {y x _ Ofxa-esd 111111110111.111.111 1O.°°"sina ins! MECMMVCµD[y.Y 195&158 x 95*P95 X401 a 216mml mnsWOawim emmi illinailliall l3.0 19541 65.01S,@s5 kg! 11111111111111S1111111 "1"84 co^"a{" ® Sprisp ermmela in by!!ISIS AWL II n - weG e Cmwpnmeo6mi6cmntsl 2 we m emryIe imam wn nu numm eoo tux AWG.e-AWS PoAndmp m SSC WU8I 7.� ® [swam uemiwm STANDARDSIDIRECTIVES 1111=111111111111111111111111•11 NEMA&MEC 600684-II Sat Hsi Solar Inverters ® Y""' 2Na1071.1 SIN LIL 199t Transformerless(TL}3.8 kW. 5.2 kW,6.6 kW, '7.6 kW 11111111111S1 !SEE 1647.1EES 1547.1• ® FCC SW ISCIISS 8 Wide Operating Voltage Range.65-550V _® ULn SWOQNEC ryC 60011O10S SMART ROE) •Wide Operating temperature Range'.-IS-158°P(-25- Mt) 111111.1111111.1111.1 Salamis we Ana 21..�Cs�A.m x CenoCWIWY)ar.ua High CEO Efficiency:97.5% miniiiiwirsamulavaminas -Integrated AFCI(Arc Fault Circuit Interruption) • -NEMA M%plus Salt Mist Corrosion Protection Doycfmkokerememce. Natural Convection Cooling maw ck945111 _ • Dual MPPT(5.2kW/6.6kW/].6kW) 'twri Sas!Haan@ ae �°,ea'""_wee, • Compact and Lightweight a AELTII .me on.,..«emxA.,,, T UL„9,/IEEE,6IlIEE[15411ICEO Sd• Gi AELTl1 Listed JUL.1699131 Type 1)1 NEC 690.11 c "iOIdrCILY Z pSotar Next-Level PV Mounting Technology 'rSoIdf�ILt/ ® d$ p$olaf Next-Level PV Mounting Technology IIZS Comp Components for composition shingle roofs a . 1, ......z.... :.... Mounting Block Array Skirt Interlock 440 Pad No.850-1633 Par No.850-1608 or 500-0113 Pad No.850-1388 or 850-1613 Listed to UL 2703 and UL 2582 Listed to UL 2703 Listed to UL 2703 c.44%41®4 ���S.• 4. e F ett1� t ch 411'1::� ,:1. Flashing Accessory Grip Ground Zep V2 1�:1�� Part No 850-1634 Pan No.850-1605 or 8501421 Part No.850-1511 1* Listed to UL 2703 and UL 2582 Listed to UL 2703 lasted to UL 467 and UL 2703 I weSaaraso Description • PV mounting solution for composition shingle roofs Pc • Works with all Zep Compatible Modules prv1 Auto bonding UL-listed hardware creates structural and electrical bond Class • ZS Comp has a UL 1703 Class ss'A'Fire Rating when installed using modules from 1111 any manufacturer certified as'Type V or'Type 2" Captured Washer Lag End Cap DC Wire Clip OUSTED Part No.850-1631-001 Part No. Part No.850-1509 Specifications 850-1631-003 (L)850-1586 or 850-1460 Listed to UL 1565 (R)850-1588 or 850-1467 Designed for pitched roofs Installs in portrait and landscape onentations ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 wind tunnel report toASCE 7-05 and 7-10 standards ZS Comp grounding products are UL listed to UL 2703 and UL 467 ZS Comp bonding products are UL listed to UL 2703 1 Engineered for spans up to 72 and cantilevers up to 24' T 'a Zep wire management products listed to UL 1565 for wire positioning devices (� Attachment method UL listed to UL 2582 for Wind Driven Rain C - Leveling Foot Part No.850.1397 zepsolar.com zepsolar corn Listed to UL 2703 This document does ereev expressby pop W arranty is mnared nit . productwarranty for -.._ Yas Sow4about -ecP d product rtse Ns warranty forah product ser shipped s productsthe1 referred to the productwar x k poohng a pped Z W n mse„worrier seeresportsbolor verifying duopyol Zee products Specifications oroPatents and Appspaimm pr c for verifyingM1a suitability yo p5Mrspmtlutlalor a5pec Specifications subject oMonwwl Patents enO Pops npats[oro nvwnent ft 860-18.90-001 Roil C Date 6sl eected: May 24.2016431 PM ewnenl p 81,0-1890-001 Rev C Date lost exported:May 24,2016451 PM SC325 SolarCity ELECTRICAL AND MECHANICAL CHARACTERISTICS .7 1. ELECTRICAL DATA MECHANICAL DATA More power1 Om ono,rpm Ix)ONIMax comet valtor p]ICI ]6II I Weight W Max camel mama'Mt r MI a L5 (aka)lv.. m nner-In, raC4 e Color Black less panels . er . )IA) — T!Cad 5400 Pa Rta) Po• a v) load 2400 pa Type Type , Bo B P LociMIR.arc c v I MI IR_ — _w—e _ r EPEE— r , 3 TEMPERATURECHARACTERISTICS - . . (m L I c nn u O n J( / °) mi ti -id O s �� / h e o . D. » I Ie� /: 7Ih / AT T (NORMAL OPERATING CONDITIONS) '� III ) • volratie COMM C.( AA nx Bomar urs m(enp)InI 155 ' y of o CI 66' cram it tacti A ne( I 1 More power per panel • IRRADIANCE 20%) - "moi wwwo DD With a sunlight to electricity Our 325W panel generates 20%more power than a standard 270W panel. VO' "Iv) conversion efficiency of over 19.4% DEPENDENCE ON IRRADIANCEP 1 ma the panel ranks amongst the More energy every year n More yearly energy(kWh)compared te other panels as they peNonnnp_000mna highest in the industry. That means better in the heat. panels can harvest more Outstanding Outstanding durability our energy from the sun, which means wthmore than 20addYDnaltests performed beyond what is LMRTED r ..tI Dyn„saob oPmin) currently mandated,neve WARRANTY •" `°°"°" panels far exceed clustrY standards. years Pmlm - zsv It takes fewer of our panels to More layers more power .n wt. power your home. Plus, they Manufactured bvp e S n panel axes �\ H I c u o e n er which ad d Iver of thin n nm silicon n.rERULs s e: m generate more power output o P of high efficiency Ystall neslto - glass 200w1 __ u - - -- r I wDa mnnum during the hottest times of the day, Leading warranty M" wn Our panels rank among the best in warranty coverage - - - - --- ° io z +° su ap ru v0 even In vv a rmer climates. with workmanship that extends to 15 years. A CAUTIONPleasse read tra „Iaaon manual carefully before using the product RDM &� o c c _ �. SolarCity spa¢ry.Bram }i3 "•• aoacWmm