Loading...
31C-049 (3) 88 - 90 MUSANTE DR SM-2017-0058 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS# ;12176 m °�;,, Map: 31C Block 049 b Lot SHEETMETAL PERMIT Permit SHEETMETALm t,.. Category: SHEETMETAL p. Permit# SM-20I7-0058 PERMISSION IS HEREBY GRANTED TO: Project# JS-2017-000498 Est.Cost: $24,000.00 1Contractor: License: Expires: Fee Charged:1$25.00 1 RICHIES AIR CONDITIONING&HSheetmetal-531 03/28/2018 Balance Due:$.00 Owner: KENT PECOY&SONS CONSTRUCTION INC #of Fixtures: LApplicant: RICHIES AIR CONDITIONING&HEATING INC DigSafe# AT: 88-90 MUSANTE DR UseGroup ConstClass ISSUED ON: 31-May-2017 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: INSTALL SHEET METAL DUCTWORK FOR HVAC SYSTEM,KITCHEN FAN,FRESH AIR UNIT,DRYER VENT ***LINE DRAWINGS DUE BEFORE ROUGH INSPECTION*** THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2017-006447 25-May-17 17953 $25 00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck@a northamptonma.gor GcoTMS y 2017 Des Lauriers Municipal Solutions,Inc. File#SM-2017-0058 APPLICANT/CONTACT PERSON RICHIES AIR CONDITIONING&HEATING INC ADDRESS/PHONE P O BOX 407 (413)789-1244 O PROPERTY LOCATION 88-90 MUSANTE DR MAP 31C PARCEL 049 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid IS T7 Building Permit Filled out Fee Paid AReUf EOn: INSTALL SHEET METAL DUCTWORK FOR HVAC SYSTEM,KITCHEN FRESH itte ,,,yyynnappplY/T AIR UNIT, DRYER VENT New Construction Non Structural interior renovations pQ/`C ft Addition to Existing � � ( I�fv" Accessory Structure Building Plans Included: Owner/Statement or License 531 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project : Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit fromoConservation Commission Permit from CB Architecture Committee �Pertnit fr. Elm Street Commissi Permit DPW Storm Water Management ire of B ilding Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. all Commonwealth of Massachus tt MAY 2 4 7G.i 7 nc.21 Sheet Metal Permit Date : IhP1 kiri Permit# c5/Yl 17-30 Estimated Job Cost:s15-1, MO' Permit Fee: $ Plans Submitted: YES NO ✓ Plans Reviewed: YES NO Business License # o`t`13 Applicant License# S3 I Business Information: Property Owner/Job Location Information: Name: Qta7»dtS AIC t iil'G. X C_ Name: PalS(F. SCS I'S QhCt'RtX71'l0t3 Street: cc, 407 Street: Lot Di G f c..)si JKb City/Town: ARttxiM M1P. o1 OOI-°Lien City/Town: 14.gkni A MitlIz 1 MQ , Telephone: 413 In- I a4i Telephone: 413 `i t t- 10:n? Photo I.D. required/Copy of Photo I.D. attached: YES NO Building Type: Residential: 1-2 family Multi-family Condo/Townhouses Commercial: Office Retail Industrial Educational Institutional Building Cubic Footage: under 35,000 cu. ft.le" over 35,000 cu. ft. Sheet metal work to be completed: New Work Renovation: HVAC ✓ Metal Roofing Kitchen Exhaust System(/' ystem( Chimney/Vents Provide brief description of work to be done: FA(3,R%c f€ ANJ Y$4S(HLt, SNGTT t^riC-Ya_ Ocxsru)VRIC Frit WIAC SysTemi k,tic>iEN Fail , Ffissivi Alt UNIT') 0Pi62 UGIT INSURANCE COVERAGE: / I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yes❑ No 0 If you have checked Yes,indicate the type of coverage by checking the appropriate box below: A liability Insurance policy El/ Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box ,I hereby certify that all of the details and Information I have submitted(or entered)regarding this application are We and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Progress Inspections Date Comments Final Inspection Date Comments Type of License: By eMaster e Title ❑Master-Restricted `F�++..G,A. n ' iSm.6 - City/Town rf- lure DJoumeyperson Signature of Licensee Permit# p DJourneyperson-Restricted License Number: m- 5p I Fee s ❑ Check at www.mass.novldpl Inspector Signature of Permit Approval Load Short Form Job Data: mum Entire House By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Inds nal Lane,Agawam,Ma Project Information For: LOT 27 C VILLAGE HILL, NORTHAMPTON, MA IhU:w.t6 Design Information Htg CIg Infiltration Outside db (CF) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Best Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 28 24 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1432 cfm Actual air flow 1432 cfm Air flow factor 0.016 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.95 ROOM NAME Area Htg load Cig load Htg AVF CIg AVF (ita) (Btuh) (Btuh) (cfm) (cfm) FIRST FLOOR p 1490 38072 12827 618 686 SECOND FLOOR p 1968 50198 15391 814 823 Entire House d 3458 88270 26777 1432 1432 Other equip loads 0 0 Equip. @ 0.92 RSM 24635 Latent cooling 1489 TOTALS I 3458 I 88270 I 26124 I 1432 I 1432 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 05 Wr.ghtsOft" RighLsu nee u mv¢rsa 20151s01s Rslln310 2017-May-15 1oPage1 Pag 1 PDSWICHIE'S PECOV LOTA 27 C VILLAGE XILLmp Cain=MP Front Door faces. N Load Short Form Job: Data: ' FIRST FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project Information For: LOT 27 C VILLAGE HILL, NORTHAMPTON, MA Iht1s'.w,-66 Design Information Htg Clg Infiltration Outside db(SF) 0 87 Method Simplified Inside db(s F) 70 75 Construction quality Best Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 28 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil Na AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) DINNING ROOM 169 5389 2704 87 145 KITCHEN 13 156 3143 955 51 51 FAMILY ROOM 360 10665 5519 173 295 LAUNDRY/MUD 117 2495 969 40 52 BATH 1 72 1090 85 18 5 BED 3 216 4819 749 78 40 BED 2 204 5482 969 89 52 BED 1 196 4989 876 81 47 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wr htsoft son-may-Is10.52.05 Ri951Sui1 b u nrversa1201515 0.10 RSUI7313 Page 2 ..ADSRICHIE'S PECOY LOTH 27G VILLAGE HILL mp Calc=MJ7 Front Door faces'. N FIRST FLOOR p 1490 38072 12827 618 686 Other equip loads 0 0 Equip. @ 0.92 RSM 11801 Latent cooling 644 TOTALS I 1490 I 38072 I 12445 I 618 1 686 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. _ 2017-May-151052:05 ^. wnyhtsoftt Right-Suite®Univ ersa1201515G 19 RSU17313 Page 'L� ...ADS7RICHIE'S DECOY LOT A 27 C VILLAGE HILL.rup Calc=MJ7 Front Dow-faces: N Load Short Form Job: SECOND FLOOR Bye: RICHIE RICHIE'S AIR CONDITIONING & HEATING SI Indus**Lane,Agawam,Ma Project Information For: LOT 27 C VILLAGE HILL, NORTHAMPTON, MA PAUsKlaCt Design Information Htg Clg Infiltration Outside db (°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Best Design 1D(OF) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 28 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Mg load Gig load Htg AVF Clg AVF (117) (Btuh) (Btuh) (cfm) (cfm) 2ND FLOOR MUD 144 3230 482 52 26 KITCHEN/DINNING 391 9349 1537 152 82 BATH LAUNDRY 2 204 3732 462 61 25 BED32ND 156 5180 2685 84 144 BED22ND 360 7180 967 116 52 BED 1 2ND 270 8535 4545 138 243 FAMILY ROOM 2ND 256 6891 3472 112 186 BATH 2ND 96 1221 62 20 3 STUDY 91 4880 1179 79 63 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. _ Wright-Salt 2017-May-15 ms2 05 Riht-Suiter.U*versal 2015150.10 RSUI7313 Page 4 CLa _ADS\RICHIE'S PECOY LOT A 27 C VILLAGE HILLrup Calc=MJ7 Front Door fares'. N SECOND FLOOR p 1968 50198 15391 814 823 Other equip loads 0 0 Equip_© 0.92 RSM 14160 Latent cooling 845 TOTALS I 1968 I 50198 I 15005 I 814 I 823 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2017May-151652:05W! ht-50R' Rig 2015150.19 R5U1]313 Pages ADSRICHIE S PECOY LOT A 27 C VILLAGE HILL rup Calc-MJ] Front Doorf.w : N ARI Ratings for Tranc 4TTB6024A1 -Expanded Performance Table Page 1 of 2 GgwA4MG847 5?-imie't>sii6eic OD MODEL II)MODEL FURNACE NOM CFM ARI REF if 4TTB6024A1 4TXCB025BC3 TUII2B060A9V3 600 5883636 Published Dale:04/30!70:s COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES OD AMB W WB CAP 72 75 78 80 KW 59 [ 19.2 14.9 16.6 r129 17.7 140 63 20.1 123 [ 14.1 15.7 16.8 [-1.42 85 I [67 213 9.9 11.6 L_.. 133 L 14.4 1.43 I III 7I. ,l 233j1.. 7.6_J 93 L 11AJ 12.1 Il 1.44 -I 59 17.8 14.3 ( 16.0 L 17.6 IL 17.7 1.59 95 63 18.7 11.7 [ 135`IL.... 15.1 -Ir161 -1F-1.60 -I. 67 I 19.9 C 9,3-1 11.0 12.7 13.8 1.62 r 71 216-1 7.0 8.7 10.4 11.5 1.63 L 59 16.4 11 15.4 L.. 16.4 I 16.4 1 1.77 63 17.2 111 12.8 14,5 15.6 1 1.79 105 c 67 18.4 8.7 10.5 12.1 13.2 1.81 71 20.0 r 6.4 8.2 L 9.8 r 10.9 1.83 59 15.1 13.1' 14.7 15.1 15.1 I--1.96 63 15A 10.6 II 123 Ir 13.9 L 15.1 I 1.98 115 67 -1(... 16.9 r 81 r 9.9 L. 11.6 JL`.12.7 2.00 -' 71 l 183 5.9 L 7.6 II 9.2 J 10.4 J 2.02 „ USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW _....... AIR FLAW RATE,CM .i CAPACITY MUMMER JTOTAL POWER � J . L.... 098 I 099 675 II L02 li r-- 101 ARI RATING FOR COOLING cern I CAPACITY(A)TE3r I SEER -ll_ EER 11 730,,, 20600 16.00 ���1300 - A.R.I.Standard Capacity Rating Conditions - ART.STANDARD 210/240 RATR4O CONDITIONS-(A)Cooling 80°F.D.B.,67'F.W R.air aiming indoor coil,95°F.D.B.air entering outdoor coil, (B)nigh Tempnnue}hating 47^e.DB,43°F.Wit air mans outdoor colt 203,an.a aiming Indoor coil (C)Low Lempetmiie Heating INF.DB_,13°F.WE.a entering otnaoorCON 70°F.DB airemmmg boor coil.0))Roga indoor airnow for heating 't is the same as for cooling. A https://w W w.comfortsite.com/resources/literature/ratings/5883636.html 5/5/2014