31A-169 (10) 66 MAYNARD RD BP-2017-1383 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31A- 169 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2017-1383 Project# JS-2017-002304 gst Cost: $35795.00 Fee:$75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class; Contractor: License: Use Group; PIONEER VALLEY PHOTOVOLTAICS 106329 Lot Size(sq.ft.): 7492.32 Owner: MARTIN ROBERT Zoning:URN WOW Applicant: PIONEER VALLEY PHOTOVOLTAICS AT: fib MAYNARD RD Applicant Address: Phone: Insurance: 311 WELLS ST- SUITE B (413) 772-8788 Workers Compensation GREENFIELDMA01301 ISSUED ON:6/I/2017 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALLATION OF 8.28 KW 23 PANEL SOLAR ARRAY ON ROOF POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House Si Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Finale Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 6/1/2017 0:00:00 $75.00 212 Main Street, Phone(413)587-1240.Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File# BP-2017-1383 APPLICANT/CONTACT PERSON PIONEER VALLEY PHOTOVOLTAICS ADDRESS/PHONE 311 WELLS ST-SUITE B GREENFIELD (413)772-8788 PROPERTY LOCATION 66 MAYNARD RD MAP 3IA PARCEL 169 001 ZONE URB(I00)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid �{,�� Building Permit Filled out J� Fee Paid Typeof Construction: INSTALLATION OF 8.28 KW 23 PANEL SOLAR ARRAY ON ROOF New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 106329 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOyclATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR _Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit _ Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management afio1 ��� 5 -2 / —/7 Sirrie'f u din• 0 icial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning& Development for more information. 40 U4 .1 QA R ----- - PV Squared Solar(www.pvsquared.coop i,-) Phone:413-772-8788 Fax:4I3-777-8668 3n Wells St.,Ste. B(Greenfield,MA 01301 3 L I MA Elec.Lic.A13764(MA 14/C140077 Dear Town Inspections Officials, Please see our enclosed applications to permit a Solar Photovoltaic System in your jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp, employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our Greenfield, MA Headquarters since 2002. PV Squared is committed to complying with all Commonwealth laws and regulations. Our worksite guidelines are created with the intention of exceeding all safety, electrical, and building requirements as defined by their respective jurisdictional entities. This includes the work of people from multiple disciplines, including electrical engineering, structural engineering, civil engineering, electricians, construction supervisors, roofers, and their associated helpers. We are a company that values training and education. We make certain that every individual is qualified for the roles and responsibilities that they assume. It is our policy to pay for the employees travel and training time and cost of the education, including CSL and Journeyman and Master Electrician classes. As an electrical contractor we are furthermore guided by the January 30, 2009 Massachusetts Board of State Examiners of Electricians (BSEE)judgements, and rulings that have followed. We pay strict adherence to these mandates and all electrical work is conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also understand that non-electrical tasks associated with a Solar installation can be completed by non-electrical workers, such as CSLs and others. I have attached our installation policy for your review, as well as a list of example non-electrical tasks. Should you have any questions or concerns regarding this policy or delineation of work, please let us know. We are a learning organization that is always trying to improve on what we do. Respectfully, Adam Thurrell Operations Manager Department use only City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Sae Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: 9 This section to be completedleby office Map 3( f Lot /09! Una 66 Maynard rd, Northampton, MA Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Robert Martin 66 Maynard rd Northampton,MA 01060 Name(Print) Current Mailing Address: 315 735.6308 See attachment (A) Telephone Signature 2.2 Authorized Anent: Pioneer Valley PhotoVoltaics Cooperative,LLC 311 Wells Street, Suite B,Greenfield,MA,01301 Name(Print) / Current Mailing Address: 413-772-8788 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building $35,795 (a)Building Permit Fee 2. Electrical (b)Estimated Total Cost of Construction from(6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) $35,795 Check Number 7045 300 This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed ' Required by Zoning This column to be filled in by Building Department • Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW O YES O IF YES: enter Book Page and/or Document B. Does the site contain a brook, body of water or wetlands? NO O DON'T KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO 0 IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House n Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors ❑ Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [p Siding[0] Other[m] Brief Description of Proposed Work: Insu]Ianon of our mourned photo—,olYlc mounting system for solar panels on south side of house our Alteration of existing bedroom Yes X No Adding new bedroom Yes X No Attached Narrative Renovating unfinished basement Yes X No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building :One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes_No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Robert Martin ,as Owner of the subject property hereby authorize Philippe Algol laud to act on my behalf, in all matters relative to work authorized by this building permit application. See attachment (A) Signature of Owner Date Philippe Rigollaud ,as Oweer/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. PHILIPPE RIGOLLAt1D Print Name f/ 05/25/2017 Signature of OZ t Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable 0 Name of License Holder: Maya Fulford CS-106329 License Number 159 Clark Drive, Giulford VT, 05301 03/14/2018 Address //Lie_ �/^� Expiration Date r 0 413-772-8788 Signature Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ Pioneer Valley Photovoltaics Cooperative, LLC 140077 Company Name Registration Number 311 Wells Street, Suite B. Greenfield, MA, 01301 09/16/2017 Address Expiration Date Telephone 413-772-8788 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes O No ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature Attachment A AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT I hereby agree to the Project as set out above, and I agree to pay the contract price according to the Terms of Payment. I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement. I hereby authorize Pioneer Valley PhotoVoltaics Cooperative to proceed with the above-referenced Project in accordance with this Agreement. I further authorize Pioneer Valley PhotoVoltaics Cooperative, or its designated representative, to obtain required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project to be used by Pioneer Valley PhotoVoltaics Cooperative for marketing purposes. A check for the First Payment is enclosed and I am returning this Agreement within 21 days of the Proposal date. Printed Name Date nl Signature Title Proposal and Agreement k 00011/08 Page z of u Rob Martin-Apra 10,109 c. Quo Weo�nsti otPCIDSzoiacizada Rog,` _ . .. Office of Consumer Affairs and Business Regulation 4114 a' _ _ 10 Park Plaza- Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration —a Registration: 140077 _ Type'. Private Corporation= Expiration: BH872017 Trf 270458 PIONEER VALLEY PHOTOVOLTAICSCOO PHILIPPE RIGOLLAUD - -= _-- - - 311 WELLS ST SUITES GREENFIELD. MA 01301 : Update Address and return card.Mark resew for change. o 2,0"5„, -- ❑ Address 0 Renewal = Employment p Lost Card Ci20 t ,„ !r.o/.LiiiaeAtueM; yE� OR,ee ofd Atain&ambeu Regulation License or regntraaon valid for indiridul use ouIy gq1111OOME IMPROVEMENT CONTRACTOR cBRo • before the expiration date. If found return to: piatrah 140077 Type: Office of Consumer Affairs and Business Regulation 170 Expiration: 9/16/2017 Pmate Corporation10 Park Plaza Suite 5Boston, j�/ Bost ,MA 02116 l� PIONEER VALLEY PHOTOVOLTAICS COOP .--- PHILIPPE Rlf1n i AIM 311 WELLS ST SUITE B GREENFIELD.MA 01301 -- - ---� Ume.ueneny Not valid with* Massachusetts Department of Public Safety Board of Building Regulations and Standards License: CS-106329 Construction Supervisor MAYA FULFORD 159 CLARK DRIVE GIULFORD VT 053015-:, •-,-,w N1 Expiration: Commissioner 03/1412018 A�® CERTIFICATE OF LIABILITY INSURANCE DATE(MLVDDIYYYY) • 1/3/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies) must he endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In Ileu of such endorsement(s). PRODUCER CONTACT Linda Powers NAME: Webber & Grinnell PHONED. (413)586-0111 __- 1 ye).141M586-6481 8 North King StreetDRESS:Power6®webberandgrinnell.coin INSURERJSJ AFFORDING COVERAGE NAICI Northampton MA 01060 INSURER ADI Global Ins. CO/Bnergi INSURED INSURER B Markel Insurance Company _ ___.. . . Pioneer Valley PhotoVoltaica Cooperative, Inc. INsuREacInter'1 Iaa. Co of Hannover/Bvergi Attn: Rim PSnkhax INSURER D: 311 Wells Street, Suite B INSURER E: Greenfield MA 01301 INSURER F: COVERAGES CERTIFICATENUMBERS4aBter limp 1-2018 REVISION NUMBER: THIS 15 TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, ' EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. DTR TYPE OF INSURANCE �ADDiWVDR POLICYDEFF POLICYMWDDI EXP LIMITS LTR ADO i UB POUCY NUMBER I TEFF) (PONDY EXP X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED 100,000 A I CLAIMS-MADE ; X OCCUR PREMISES(Ea'occurrence) $ EGGCR000241217 1/1/2017 1/1/2018 MED EXP(My one person) $ 5,000 PERSONAL 8ADV INJURY $ 1,000,000 EL _. GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE 8 2,000,000 XPOLICY 71,IECO] 1 1 LOC PRODUCTS-COMP/OPAGG $ 2,000,000 PR OTHER' $ AUTOMOBILE LIABILITY - (Ea CAaBBINEDr'SINGLE LIMIT $ 1,000,000. Ai ANY AUTO BODILY INJURY(Pm person) $ ALL OWNED Y AUTOS SCHEDULED AUTOS EAGCR000241217 - 1/1/2017 1/1/3018 BODILY INJURY(Per aviden0 $ PR PERTY ',K. HIRED AUTOS X POO WNED AU (Per axiaentOAM4GE $ Underinsured motodsl01 split $ 100,000 X UMBRELLA UAB X OCCUR EACH OCCURRENCE $ 3,000,000 B EXCESS LAB CLAIMS-MADE AGGREGATE $ 3,000,000 DED X RETENTIONS 10,000 EXAGR000241717 1/1/2017 1/1/2018 ' S WORKERS COMPENSATOR XII$TAME OETH AND EMPLOYERS'LIABILITY — -- - ANY PROPRIETOR/PARTNER/EXECUTIVE Yn N/A EL EACH ACCIDENT $ 1_000,000 OFFICERMEMBER EXCLUDED? I Mandatory andatory in NH) - RNCAR000241217 1/1/2017 1/1/2018 E.L.DISEASE-EA EMPLOYEE $ 1,000,000 It yesdescribe under DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT $ 1,000,000 C Commercial Property CPT/17E174800 1/1/2017 1/1/2018 • Business personal property $1,750,000 Inemlle8on $350,000 DESCRIPTOR OF OPERATIONS/LOCATORS/VEHICLES (ACORD 101.Additional Remarks Schedule,may be attached if more apace is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE For Informational Purposes Only THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Linda Powers/LMP '"--T°"' u_) ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD INS025:2ni4niI The Commonwealth of Massachusetts Department of Industrial Accidents _ e= Congress Street, Suite 100 _.r_�_ a Boston, MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name Basivess/OrganiratioMndividua0: PIONEER VALLEY PHOTOVOLTAICS Address:311 WELLS STREET, SUITE B City/State/Zip: GREENFIELD, MA 01301 Phone ft:413-772-8788 Are you an employer?Check the appropriate box: Type of project(required): I-0 I am a employer with 45 employees(full and/or pare-time}+ 7. 0 New construction 20 1 am a sole proprietor or partnership and have no employees workingfor me in 8. ❑Remodeling any capacity.[No workers'comp.insurance required.] ID I am a homeowner doingall work myself.[No workers'comp. 9. Demolition❑ Y insurance required.]t 10❑Building addition 4.0]am a homeowner and will be hiring contractors to conduct all work on my property. 1 will ensure that all contractors either have workers'compensation insurance or are sole 11.0 Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13. Roof repairs These sub-contractors have employees and have workers'comp.insurance.: ❑ p 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 14.❑� Other SOLAR PV 152,61(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box 01 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. 1Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: HDI Global Ins. Co/Energi Policy#or Self-ins.Lic. #: EWGCR000241217 Expiration Date:01/01/2018 Job Site Address: 66 Maynard City/State/Zip:Northampton, MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to 5250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and aides of perjury that the information provided above is true and correct. Signature: Date: 05/25/2017 phone#:413-772-8788 Oficial use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: duq R MARTIN - NORTHAMPTON SG 1. i •elr a so � y fl =1 ,=-. 11 :: ens _ . cU � n n. l = = In) Et] \� Owner Rob Martin Address: 66 Maynard rd Northampton MA, 01060 1111111a��� Phone: 315.735.6308 e-mail: rwtmartin@gmail.com ___ System Size : 8.28 kW DC PV Array: (23) SPR 360 ACPV in portrait as two Sub-arrays on main house and newly constructed addition. ♦ -a J Mounting: SunPower Invisimount racking on L-feet on Quickfoot bases. Roof Structure: Main house roof 2x6 rough `r cut rafters 18"OC, 35° pitch. Addition roof 2x12 rafters, 16"OC, 8/12 pitch. See PE Letter. Roofing Material: Asphalt composite GZ� May 12,2017 Mr. Matt Valliere Pioneer Valley PhotoVoltaics Cooperative Inc. 311 Wells Street,Suite B Greenfield, MA 01301 Re: Martin residence, Northampton, MA GZA File No. 02.0172356.10 1-25 PV Squared No. 11618 Dear Mr.Valliere, At your request GZA has reviewed the information PV Squared ("you") provided on the roof and supporting structure at the Martin residence at 66 Maynard Road, in Northampton, MA.The purpose of this review was to provide an opinion as to the structure's ability to support proposed rooftop photovoltaic panels.The proposed PV array is to be installed over the existing house and a proposed addition.You have also provided architectural plans for the proposed addition.You also provided catalog information on the proposed photovoltaic (PV) panels. Both the roof structure information and the information on the proposed PV panels are attached to this letter for reference. You are proposing to erect PV panels on the south side of the roof of the house and addition.The house is a two-story wood framed colonial with an attic. The proposed addition will be and "L" off the existing house and the addition roof will intersect the existing house roof with valleys. The architectural plans for the addition call for 2x12 rafters at 16"O.C.The addition roof has been designed with an 8/12 pitch and asphalt shingles.We assume that asphalt shingles will be installed on an appropriate span rated plywood sheathing roof deck.The new roof will frame over the existing house roof where the two roofs intersect. The existing house roof is framed with rough sawn 2x6 rafters at approximately 18"O.C. The rafters span 11'-6"on the horizontal.The roof is pitched 35-degrees and is symmetric about the peak.The roof deck is solid board sheathing.The roofing material consists of asphalt shingles. Conclusion: Based on the information that you have provided, in our opinion,the proposed addition roof will be satisfactorily robust to support the additional dead load of the proposed PV system.Similarly, based on the photographs and information you have provided, in our opinion,the roof of the existing house is also satisfactorily robust to support the additional dead load of the proposed PV system oppa"oai„E p'et'er V/F/mx March 72,2017 File No.02.0172356.10 T-25 Martin Residence, Northampton, MA Page 1 2 We base our opinion on the information you have provided and the following assumptions. We assume that, owing to their slippery surface,the solar panels will shed snow better than the existing asphalt shingles.We further assume that the panels will be installed parallel to the roof,eliminating any additional wind load. We assume that the roof will be constructed as shown on the proposed architectural plans.The design ground snow load for Northampton is 55 psf. Based on the information that you provided,the proposed PV panels weigh 2.6 psf(4.7%of the design ground snow load). To summarize, in our opinion, the addition, if constructed as designed,will be structurally adequate to support the additional Dead Load of the proposed roof mounted Photovoltaic System, as is the existing house roof. If we can be of further assistance, please call Jonathan Rugg(603)2324794 or Carl,Goldknopf(603)232-8792. Very truly yours, GZAGEOENVIRONMENTAL, INC. ",, //�J, onathan Rugg, P.E.' Carl Goldknopf, P.E. ' Project Manager Senior Consultant — y Bradford Roberts,P.E. emottiOn Senior PrincipaijDivision Manager STRUCita N0.31988 ;p 111 Attachments: -Existing Building, Proposed Addition,&PV information 5OUq J RF 4 nti 0 MARTIN - NORTHAMPTON STRUCTURAL ASSESMENT REPORT 5/2/2017 S•.q' y0` • • s' v Phi q,, ♦ Na Owner: Rob Martin 66 Maynard rd Northampton, MA 01060 System size: DC STC kW: 8.28 Array: (23) Sunpower RES-ACPV-360-WHT. 2 Sub-arrays. (8) Modules on South roof of main house roof and (15) on South roof of newly built addition. See drawing below. Mounting: SunPower Invisimount rails on L-feet on Quickfoot bases. See data sheets Roof Structure: Main house: 2x6 rough cut rafters 18" OC, 35° pitch, Addition roof: 2x12 nominal rafters, 16: OC 33.69° Pitch (8/12). See drawings attached. See building plans for new addition. Roofing Material: Asphalt composite shingles sQVAR Q p -•%, MARTIN - NORTHAMPTON STRUCTURAL ASSESMENT REPORT 5/2/2017 • o , ♦qt . 50 Y a .- In — •O �: n v n = 1 U I flu f u = � m m � LU � nI C'.UMman a MEI Ell an nit snimUM IIIl - In ns a� -)u mlw CI / ® jIIiIiiiiiiuhi!i;1111 4:�W /a. i ms, _ '� ' oo - .s 1 • i i H : s 1111 SpUq 4 QF e MARTIN - NORTHAMPTON `• STRUCTURAL ASSESMENT REPORT 5/2/2017 • / `� q i a '+° Visual report (Main house): * 1. Ceilinglir4ed. h`plywood paneltg Roof pitch 35 - 1z? p, Ii ddilh Jd N P Rafter dire w ns 2x6 rough Rafter dimensiaps 2x6 rough 4 „ cut 5QU4Q $ F 3 . 0 MARTIN - NORTHAMPTON `d STRUCTURAL ASSESMENT REPORT 5/2/2017 Stiei/ f a''y"D‘'• t: t` . , Or 4 ii Rafter spacing 18 OC I Xr<,74deck 1. V< •" _ _. f G ..-:..-...r � Ceiling joist dimen ion , Joist spacing 18" OC (paired to i rough c a rafters) RAFTER STRUCTURE IA�..:. .i'T-4 —a ' e RMPticlr 1"i-en's son: Vv.$‘ Overal Inle Roo;Dirt¢'. as ' Special Notes i l i I I_. 1 i ( i I I l l Roof plan Structural Info FF_ R 'Ranerar.. �,�L @ spaang 1p' c c. RB melenoard am,: frel RH Rlaw n uno hegh: 1I. CT Cain Tie deme --_ o j' sawre . _ � RC 1_Raga n�.r heir _. 4 ,..\\ RT Rafter Tear _. ... �5si.arg l r `KWxbe.alam. — I G _,__. _�_�—. KH Kane no mot — i: LG Eraroer grape:--- General Notes:.__–___. 'ThaIgeml b z e; Section 5ou44, PROJECT . . STRUCTURALASSES M ENT 4 * PV Squared $0�8f 1 'T1 , Q PgADDRESSLl. Y1� vDATA COLLECTED BY: r., _. rr�. �r�1311 wwa.Suite e GuenM4 MA 01391 SHEETI� a,s-nza>ea r a se" reSueCYaNIOnarlaa'en.[Wp IOD NVMSER. j DATE DRAWN BY'. –‘ V 9ou4 4 R O MARTIN - NORTHAMPTON STRUCTURAL ASSESMENT REPORT 5/2/2017 ger • '+o New Addition (see full plan set as well). 2x12 Rafters 16" OC. 8/12 Pitch. e il / '''...". /il : \ ile..*TE =_ Ali 1.1 ' jIjI .,....M -E _-- . ,� 1 ='AMM'iM00�RtMiWAFA l.44MdO�PSM AWAMI. I _ _ IM MEM ! • u _I = 11�i. LIIII Oli IM IN los -- ': ®❑ � c ❑❑. :7ate . PTIMI --....--c. P-Mte —1011 :17.ars- I ....-7 414110 ®w ma-ma Irv�!�rrr� •5i0i�i�0i�i�i'Oi�i�iVAV?fl#. i�AVO• V41I SM I I — o..._ ......... / A. r A."a e � r r. ir • SunPower® X22-360-C-AC Residential AC Module Series Design-Driven Advantages ©22 • #1 module aesthetics ano efficiency' L Unmatched module reliability — -' SERIES • No e ectrolyt'k capacitors 25-year Combined Power and Product warranty Maximize Value for Roof • Sze system for roof, not string inverter • Optimize performance of each module Expand Deployment Options • Complex roofs and parta'shading • Small systems _ _ _ • System expandability Simplify &Speed Installation Optimize System and Installation Efficiency • Factory-integrated microinverter Robust,double-locking AC connectors SunP„wer'AC Modr.es which include t ramp!! meg. • Design flexibility offsite and onsite tPower m coinvel.er, pray de a re o , zonary comh naton of nign • No DC string sizing process effcierny high reliabil ty,and module eve:DC to AC power oc ifie'son. • Fewer nsta'lation stens than competing systems Dr-s:gned specifically for use win Sun Cower nvisi'Vlpt t"andtne • Intuitive commissioning Poi Power Mon toting System,SunPower AC Mo°ules enable rapid Hilalatiorpest in class system aestnet s and JOU J o Ty, Component of Complete System • Bpltf0'Lse wish SUDPower"'' Invi5iM0Uot'" system oerlor mance.All this comes vi[ he Desi Cci bine° newer ann the Sun power Monitor ng System ann P'oc cc:'ha',arty. • Super or system reliaolliy a no aesthetics f y sunpower.com SUNPOWER ,x as zt t;c,,; • SunPower"' X22-360-C-AC Residential AC Module Series Ppwer Data SPR-X22-360-LAC 6,Jar Cells 96 Monocrystallme Maxeon®Ger III Nominal Pr anom) 360N ligh-ta smssion Temper,cgasswitharu Fro-,Gas_ Fowey-avarice -5/-OqE refien we rooting Avg =arid ER:icrI C - __-._. 222'h Eft., on mental putd'or mtec Rasing-cry. Coef Po,,e,,, -030*/°C Rasing 1 --- Frame Css5 tl - iocnea(h host AA#A roti'rg� •Three bypass c odes Shane-o erarre • Integrareo m i xre-level max mr n' powe. elgnt 455 los(206 kg) pcin:trackng Max Recommended 1 3 in 33 mrn) I MEMte Spacing AC lec,4:a! Data outaJr C 240 V(min/nom./max) 211/240/264 V 0,,L.3„,:@208 V(nim iom./max) 183208,229V Wd^dnde5 anb Certifications Opera-wig mrevi;min nom/max) __- 593/600/605 Hz a rankles ' 25 ye larked power‘,,avant,,, Out; t'0,.,er act (m r.l 099 • b-year l m ted procu a ra ii, I ACb (ority,, cus uu-put,-t 'lilt C 240 V 133 A - UL 1 4 iciuding corro,iance win (EMIL locus Output wrent a 208 V 154 A appcaLl• equ remert IEEE"547 and ACP.. — 20 Cunt O_ w eput=oer 20 Nv Ir-i., 15421 D.,. "-1,-,cv 96 0 k - FCC and 5-003 Cass 6 rs Max.U 20 A 3a CCircuit a 240V 2(5 ng onase) • AC module-yoe 2 Fire Rayed N,lax n , /0 t, Harm,c C r La.205V 0(cAu ooILi • JL2 V]Lsrerl when Laled'....:0 Cc¢ficatiors InvisiMou-rt`a li Testa: Oper ;:rig CondPaons Clay-, FM'l Fume -Ile with z inurs r and A ,en du:mice between 1 Ce-at g lenrp -40--to-185"F(-40`C c 85°C 'sof s.. aeunjornmo Scn>owcr Mdt Arr o crt Temp. - F)5C°C; rnodue frame-s<35 ,889 cm: Max Lsad z c 62 osf3r 305 kg/m from&La,< tern tag ,rre oar(A()MeJLI t des gria'ion Sr, 2 r'ist 6000 Fa 6'1 Kiln?froor I enables insal ation n accoriaricfr with NEC ICE 25 mi-r)r amemr ha a. SJ mph C23 64011 DSCI cance -.. ";'% 'C Test Posent l4 elcwra r:ior;Bec. 1n e2 11 iII SUNP ,: WER .f . (4:4s -,21 vv'Z' i rF s `"s r3 `C"'' •iv S�14r�Y. SunPower® lnvisiVountTM Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • dclamp width spacing tales consistent,even modules g wifaali • P Sim e,p rilled raI splice • UL 2703 Listed integrated grounding Flexible Design _ • Addresses nearly all sloped residential roofs • Design in landscape and portrait • Rails enable easy obstacle management Customer-Preferred Aesthetics - • #1 module and#1 mounting aesthetics • Best-in class system aesthetics Elegant Simplicity • Premium,low-profile design Black anodized components SunPower" InvisiMountn" is a SunPower-designed Hidden mid clamps and end clamps rail-based mounting system The InvisiMount system and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superioraesthetics. • Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and • Best-in-class system reliability and aesthetics • Combine with SunPower mooures and engineered to pair with SunPower modules. The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. sun power.corn (2110 oatasheet SUN P W E R' r SunPower® InvisiMount'M 1 Residential Mounting System Inv s Mount Component Images i dri N M v CanP wd R..1 `Aocu e'/hrc Cane and Pai dx:' M i(annn:: C.,n, ID -e ii S Pal splico Cocnd Lug Assert.; Fr IC£p a. fig:: z a riiiiiiiiu........,. ., InvmMount Component Dera Is nv'cvount Opeating(ono ti ns -ern✓esti yr e;": perzmre _i`cm 40 =m°.9_ 1 i _ _.. • '.(1.2.' a prrt _ rf Ita. I1RFDntorce v�d a, p rF:�r a nr z�el c ssgr':>_czl ,.o nad . a:pa , I ,t _ es ez u ec„r e-vru In rsHMount Warr art les And Certifications n: _a I _ ranir. .. n k- r I Lul.mer 1.3. • u_c„i..i_en Reofkatchmeni Hardware Supported by lnvis Mounr System Design loo r oPar < ,,,rn�rt Roof Artacnmen:Hardware Wartantes ; _J,1.2 Ila le Ps") Any. .rt. I '-fore er PrioT 1 rv:rrHIF PeleuC .dd[aChnrthan-.^...rc mdr .L(_J '-nrT..:- ...Mo.',16. --Modvle Irene(noir-aompauLJe with the M1msu.lou 4zt5rem rew✓ed for hardware intercperob lit,.. ,5 tnp<rtation All Rights caved. SJNPOJJFk ill SLMPOWFR Togo.ano INVISIMOUNT arb Ira len:arks :gisrered r,le.r..,r1.s th po All FeVatle ep<pMy oRFer eSVeRveowners. 5095.06 rOT spcmeaions nduaco m me aafas,eef arewhiecr m mange wimwr noun Document#509506 ftevC SUN POWER '/ vi QuikFoot PRODUCT GUIDE 0 Exploded Product VieM/B.O.M. - 1 - Installation Instructions - 2 iumumm _ Cut Sheets - B Specifications - 4 II .' CL 4 LLI 1 ii iE A I"- 1Ua EcoFasten Solar 1 .. QuikFoot— Product Guide Exploded Product View B'II of Materials Materials Needed For Assembly O .►lif . Item No, Description of Material/Part Quantity 1 QuikFoot Base Plate 1 ® iCOryt 2 Fastener(Lengtn to he determined) 2 et 03 QuikFoot Flashing 1 I —=" 4 EPDM Washer 1 0 6 5/16" EPDM Bondi Hex 18N SWasher available)eb1 i_ 7 options 1 cU Required Tools © 1 \ v h* "11".........."....""*"'"•40, iO r r 4 t* oPp- -t mz 877-859-3947 EmcsstenSolcAlcontent protected ensm5522ghts rese810/09/14 Ll EcoFasten Solar products are protected by the following U.S.Patents 8.151,522828,153,]996281et 398 320166 ]13828.146 299132 8.209.914828.245,454820.2]2,1]4 B2 8,225S57e2 61 n k11 1' , ilL, QuikFoot- Product Guide Cut Sheets: QF-AL-Ease ft yil 2X 0 .33in It. , t' ' [8.38mm] I _ i1 4c' �Al_�� i 16vil u co N 0 o c A 1 .50in [38.10mmj catiiil 3/8"-16 Stud QF-M : 1 .5 ' 1 QFL : 1 .75' 1 i A 1 877-859-3947 EcoFasten SolarAll content protected under copyright All rights reserved.10/09/14 3.1 EcoFasten Solar products are protected by the following U.S.Patents'.8,151522 B2 8.153 700 132 8.181 398 B2 8.166,713 B2 8.146.299 B2 8 209 914 82 8 245 454 B2 8 272 174 B2 8,225557 82 i I QuikFoot- Product Guide Cul- Sheets OFL-812 R.38in [9.53mm ] .032in [0.81mmi —Pr • A t (Illa 12.00in [304.80mm] i I o IIII A. 3.00in 4 [ 76.20mm . 1I :;) wmmadon k 2 50in 8.00in [ 12.70mm ] Dui ,-....-- [203.20mm] y 877 859-3947394] EwFssten5olce cofent protectednqU.S. tents: .151.522 B2 rights 7005reserved 1198828 32 EcoFasten Solar products are protected by the following LLS.Patenls:8451 S22 B28.153.�09828.18189B 828A66]13828.148.299 82 8,209.914 B28.245.454828.272.174 B282255A B2 ,I's i iii QuikFoot— Product Guide Cut sheets Bracket Opt'ons - SCL i C'-3 li . 1 , i '1 .1'2; .i , 3/8" 1 I �. 4, ; co A 46 SERRATIONS , cos 1 `+J cill so_la _ 1 v i i i R1/16' 1 7 — 1/4" / bo 6" 44 � 3/4.. I, R.005 � . tii R.010lir „, • 2X R.01 o4 60.00° c ° 3/8"-.002 \. 1/8" �`� \\/ 0 7/8' X 82° DETAILSCALE 1 , i 87 7-859-3941 394] Eauctsaten Solar'All content protectednqU.S. tens: .151.522 B2 rights reserved 1198 82 10/09/14 3> EwFas�en Solar products are°mtecte40v the following U.B.Patents:8.15L522828.153]96 B20.i0t,398028166,713 828.146.299 B2 8,209,914028,245,454028.272,174828.225.557 082 QuikFoot— Product Guide Soeci[i,cations PART 1 —GENERA: _' SUMMARY 1.3 SUBMITTAL A. wORK INCLUDES A. Submit manu`acturer's written specifications- B. Base plate is 6000 series aluminu m with one I ' 1. Quikroot base plate attachment bracket that B. Submit standard product cut sheets . PEM Type Press-InStud18.855- ataches direct to the roof deck. C. Subm t nstal at on instructions. C Fasteners to he compatible with chosen roof 2 Provide appropriate bracket and fasteners and meets rr `e oof syste'r. D. Submit orodu¢spedAc load test data, showapplicationpear ed pull out values ! heirultimate and allowable load values specific to as shown in Toad test dataet . B. RELATED SECTIONS the roof deck specified forme project D. Counter flash ng is.037 gauge aluminum em- Section 07600. Flasuirp and Sheet Metal bossedunte flash aCCep sape0-37 of stainless steel base i s L Section 07500 Ree ng 1 a QUALITY ASSURANCE plate 3Dnior'.Administrative and Procedara', 'nstal he experienced in (he Installation of Recuremen s specified roofing material for no less than 5 years in 2 3 FINISH 4 ['Ripon]Thermal and Mo stare Protection the area of t re prpIect. 12 S.Si EN1 DESCRIPTION] A. Bracket is millfinish alum Hurn A. COMPONENTS 1.5 DELIVERY/STORAGE/HANDLING B. Base flashing- Blaclk-kynar painted Inspect material upon delve ry.Notify manufacturer 1 Quik-not system consists of aiummum with n 74 hours of any missing or defective items. PART 3-EXECUTION bracket and base Mate with(i)stainless steel Keep materialleddry,covered and off the ground until stud, (1)stainless steel nut,(1)FP,DM washer . and(1)oondeo stainless steel ane EPDM 3.1 EXAMINATION CID waster_ A. Substrate'. Inspect ast nd verify if on which brackets CID 7. Fasteners PART 2- PRODUCTS aretooeInstalledandverifythat itwill wlth- A To be of meal compatible witn Quikroot stand b-ackeL 2.1 MANUFACTURER any additional loading that may be incurredEco . B Fasteners should be selected fo-compat- steners289asten Street, Morrisville,VT 05661 9 Notify General Contractor of any deficier cies C Fasteners ength should exceed or be (87Q 859""3947 before installing EcoFasten Solar brackets equa-to thatthe of:he allowable load of `^'w'r^'emfas[ensolar_com C Verify that roofing material has been installed system.See test data at r r www.ecofastensolarmm 2.2 MATERIALS correct brackets prior oinstalling solar attachment A. Attachment Bracket brackets_ 3 Sealant(i(required by roof manufacturer): 6000 Series Aluminum((noose one) • 4 oberoof manufar.merapproved- 3.2 INSTA_IATION 41 4 Num num counter flashing 1 C P SQ Slotted A. Comply with architectural dr awonsfrigs and protect S Aluminum attachment brac<et 2 F111-A e stem. 's recommendations for location of 3 SCLCNK system. Comply woh Manufacturer's written in ,A- © B. DESIGN REQUIREM NIS_ 4 SCL 1013 stallation instructions tonnstallation and layout 1 Bracket spacing to pe recommended by 5 SCF 1 3" protect engineer. 6.L-102-6" 2. Install a minimum of two fasteners per /.7-101 base plate. 8.Comp Slide 3. It is mportant to design new structures or 8.Custom assess existing a uctures to make sure that they can wtthstano retained loads. • 877-559-3947 EcoFasten Solar All content protected under copyright.All rights reserved 10/09/14 4.1 EcoFasten Solar products are protected by the following U.S.Parents:8.151,522 82 8,153 700 B2 8.181 398 82 8.166 713 B2 8.146.299 B2 8,209.914 B2 8 245 454 02 8 272.174 82 8.225 557 B2 Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 INSTALLATION CREW OPERATING POLICY This policy applies to all PV Squared employees in Massachusetts, but is particularly directed at those involved in the installation of solar electric and other renewable energy systems (licensed electrician, learner/apprentice electrician, licensed constructor supervisor, supervised carpenter and laborer). When engaged in this work as an employee of PV Squared on a PV Squared project site, activities of PV Squared employees are covered under the General Liability Insurance maintained by the Cooperative. It is the intent of this policy to provide clarity to installation situations where the applicable codes and regulations are unclear, ambiguous, or silent. It is possible that a municipal building or electrical inspector could interpret the codes and regulations in a manner that differs from what appears here. But this policy sets out, in writing, how the cooperative interprets legal work requirements and unclear details. It is an internal consensus working model, intended to be revised and improved from time to time. As a general matter, a city's or town's Building Commissioner is charged with enforcing the State Building Code, Plumbing and Gas Code, Electrical Code and Architectural Access Code. The commissioner addresses concerns about the safety, accessibility and security of construction of homes and businesses. The commissioner also enforces zoning bylaws. In accordance with Massachusetts General Law, employees of the cooperative who perform electrical tasks and activities must hold a Massachusetts journeymen's electrician license or be under the direct supervision of such licensed personnel. These tasks and activities include installing electrical wiring, conduits, apparatus, devices, fixtures or other appliances for carrying or using the electricity associated with Renewable Energy Generators (electrically active solar photovoltaic modules, wind turbine-generators, hydroelectric generators, etc.). In no circumstances shall the Massachusetts licensed journeymen have more than one learner or apprentice working with him/her or under his/her supervision. Mounting structures come in a variety of configurations and have differing functional and physical characteristics. A structural component or assembly becomes associated with electrical work as the Renewable Energy Generator is electrically bonded to the mounting structure. Unless otherwise noted in M.G.L. c.143 §§3 through §§60 inclusive, all structural work defined as follows shall not be required to be performed by a Massachusetts licensed journeymen electrician: • Structural improvements • Elements of a Renewable Energy Generator's support structure that fall under a building permit (e.g., assembly of top-of-pole mounting structure on steel pole with concrete foundation prior to execution of any required electrical bonding of the support structure and associated renewable energy generator (solar electric module) to the support structure Policy # 9 Installation Crew Operating Policy Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 • Roof-top mounting support structures including but not limited to posts, stand-offs, flashings, feet, and mounting rails • Operation of heavy equipment involved in moving, hoisting, digging and other tasks • Earth work, excavation and concrete work • Manual labor involved in moving loading and unloading of equipment • Moving, hoisting, and attaching an electrically bonded panel assembly (defined as one or more assembled and electrically bonded solar electric modules) to an existing structural support designed to host the panel assembly. Note however that construction of a panel assembly is an electrical task due to the required electrical bonding activities. Repair and Servicing of Installed Equipment Repair or replacement of an electrically bonded and/or energized renewable energy generator (e.g., installed solar electric panel) will be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician. Replacement of an installed inverter must be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician, if the work requires removal of AC and/or DC conduit and associated wiring that originates outside of the installed inverter (e.g., removal of external AC conduit and wiring between the inverter and point of interconnection with the on-site electrical service). Note that this activity may require a wiring permit in some local jurisdictions. This requirement also applies to the servicing of an installed inverter that involves replacement or repair of components and wiring internal to the pre-manufacturer inverter (i.e., factory installed components that were originally shipped with the inverter) even though such activity may not require a wiring permit. Replacement of an installed inverter may also be performed by a qualified technician who may or may not be a licensed electrician or properly supervised learner or apprentice working with a licensed electrician if the inverter is of a "plug and play" design. Such a qualified technician can also performed other tasks that include installation and servicing inverter-based performance monitoring systems (e.g., replacing internal communication cards, making "plug and play" ethernet connections, etc.), assuming these activities do not require creation of a new AC power source circuit to operate the communication system(s). Policy # 9 Installation Crew Operating Policy Non Electrical Work at a typical PV Squared installation: • All Material Handling tasks o Module prep and moving o Ladder lift set up o Ladder set up o Trash/recycling removal and sorting • Structural Improvements o All carpentry work • Roof Mount Array o Fall protection anchor setup and removal o Layout and mounting bases o Racking up to but not including"bonding/grounding related activities" o Leveling of racking o Sealing seams/patching roofing/additional flashing • Ground mount array o Site work, earth moving o Trenching/digging o Construction of racking up to but not including "bonding/grounding related activities" • Conduit run o Making holes in structure o Fire blocking,sealing penetrations o Stickers • Power Board o Build wall, hang plywood o Stickers • Interconnection o Stickers • Monitoring o Wifi options o Any"plug and play'devices o Programming of monitoring devices o Computer based activities • Installation completion o Final building inspections o Install pictures-See checklist o Update one line and roof drawings to reflect as built o Completion checklist o Notes for others o COC left onsite • Misc o Truck Organizing o Material List, ordering o Daily check-in o Customer interaction and training activities e Open L-feet facing UP on Ecofasten '� main house 7� �1A Qui kfoot bases attached to(3)2x6 ����� ��Igil r) wood blocking with(2)GRK RSS 11) 5/16" x 3-1/r fasteners,as needed Install rail within clamp to comply with allowed rail cantilever Array Start Point admgon 44 range allowing to fit - 2 x 12 Rafters @ 16" OC e''7 flashing below ridge See Note#1 `�''� mew ESTIMATED BILL OF MATER IALS I PART MAKE&MODEL NO'. k i - - - - 430' roof - — _� RAIL INvlsMou NTsro 15 SPLICE• INVISIMOUNi STD 12 l BASE OPEN L-FEFT ONQUIKFOOT 47 4. - - - - 371" array& railing; - — - - 1" BLOCK (3)2X6 FLAT 4 MOD. SPR X22-310-C-AC-WHT 15 .nn''''b' i 3" '� _ _ _ — _ _ _ PI ...� `1 PROJECT tiorEs.4 fro r - N. ' \ I start 0 1' n corner as PHI ma, Allow wmb _. . W __ 1 ® valley with house.• CJD 54' , 129 � r, 129 _. verified on __ 2 Exact framingl b - - _. _. - 3 _. - 21 a 58 4" 3. SlideInter r .Ins withblor as needed avoid LS ® ri _� ® ses. 4. Unless otherwise1 d bases are 4 _._ staggered s4z R C. o�9 i 4( 36' 32" / / n82Y. 3P" Xtin 5Max. p ] for Main tilever a 17% " 64 for Add . army b Max. Mown 24"for ® � . ® ei® ® � 124' both ubd should exceed gnofadj P 7 Additional alternative bases be 1217„) 129y" __ k ® _ ja „ I array rtequipment specifications. ®- 156" roof 11a � p �lnrrnnl r�tl A M 5pI I yfrom bases an and tl Id np5 0. Modulena G5 frame with ons o } pr„ ® ® — ® " I ® I. ID. Clamp cenfwithin2 and lB. of either ee module frame 4" ---)`W9 3Y4" > 16" i- n. Torque fl`VISIMOLII11 clamps In Bso-ms _ 12. Torque CF to-rail 1 nuts375 in lbs. 176" roof --__ 123%z' -- k . 583/'' _ 13. Roof materials asphalt shingles IA RPI NI n- mOpen on Ecofasten 7-ici-7:--N\ a uikfoo t6 aseRsSattached t eet facing Pooffs structure 185/4'arraySiclamp r.l nge 14" I twith - -- - 1 i railing1 —4 staggered and spaced not more than 48" \ / 29" J09. MARTIN • SITE. 66 Maynard Road ADDITION = Northampton,Mnom60 p' ,(/ nA } a REVISION DESCRIPTION DATE CJc e/ S �j�cc�� 1#O '/cK. cei weet 4 198" roof - - k � a /� c� S r7 Leper Qe � City of Northampton HILL. Array Layout &1112 Department By. DG 61e Plan Review DATE: 5/2.1/2017 v rzaPAGE' SGL: 3r8"=1'-0" 2112 Main Street sHFo 11618s¢e 1r'xn" sHEEr A_01 Northampton, M' 110"' PV SQUARED 311 WELLS STREET, SUITE D "/ GREENFIELD, MA 01301 11> a ' main house Open L-feet facing UP on EcofastenC Array Start Point daacedtmor2 x 6 Rafters @ 18" OC staered and saced not mare th48" / 44 addition`-le 1 Plan View ri I 372" roof ESTIMATED BILL OF MATERIALS ) IK \I PART'. MAKE 8, NO'. RAIL INVISIMOUNT STD } 208Y2' array& ailing \ vw.rorr SPLICE EVISIMNT STD2 rt,uoat BASE OPEN ONQUIKFOOT T 24 -v., BASE oPCEEET ON Ec044F NDE) 24 } _. - O. } MOD. SPRH22-360-CAC-WHT 8 } 0 ® ® ® ® a. PROJECT NOTES'. 1. Array start point at North East corner as __ _ indicated. Allow4"minimum at roof 2 ___ _ _.. _. ... __ _ __. _. ___ _ __ valley With addition. y18 d 2. Exact framing location to be verified on 61555 00 1/4' 42" 3. Slide rail assembly as needed to avoid a array i 97)/4" k 1111/4" ' interfering with 4. vmefsomerwNsnoted or bases. 4. re it 5. Max.allowable rail span is 72" or ® ® -- -® -- 1 ltl J -® - Pi I - - --® ® 6. Maxellow allowable for Addition.lover is 24Mlon staggeredspaced 48 OC rai _ both ba -n shouldle exceed iLS 123" _ �-_ __ - _ _ —array ® installed length tali t span. fie 7 Additionalbasesmaybe tntlnalternativeroof conditions in compliance with rail and equipment specifications 1 " k 28' _. -- i i 5" 8. Maintain splices 7/z k 28' 36" i i11Yz 8Y4 p 'away from bases and 1so" module ps has roof 9. Module 65 frame wlln dimensions of 614'x412"x10". -- _ Torque and 16 . _ t end of theframe. T q v ampsto85in-lbs. �_ kque LF -lbs.p ® ® I ® 13. material rs asphalt es 6'min _ __ _- _ _ - clamp range 14" I 83'array 44Y4' 8t railing k v yyalll&r --x Jo0'. MARTIN Open L-feet facing UP on Ecofasten o o o - 53 sire 66 Maynard Road 8PT bases attached to roof decking by \l,�.j o Northampton,MA 01060 (8)XHD 415 fasteners as neded to ��` # REVISION DESCRIPTION DATE maintian allowed rail cantillever o 0 0 MAIN HOUSE a erg,n.. } P 132'' roof k TITLE Array Layout City of Northampton 9v' Dc FRN 4. 11618 Building Department enl DATE srz4rzol> SHEA {(///{,L/�//�L ✓//////////// { / Plan Review SCALe. ve 17' SHEET. A-02 SIZE: 11Th lir. 212 Main Street Northampton, MA 01060 tn." PV SQUARED VnT WILLS TTT wnsemO. IAA 01101