Loading...
18C-033 (2) 34 COOKE AVE BP-2017-1367 GIS g: COMMONWEALTH OF MASSACHUSETTS Map:Block: I8C-033 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2017-1367 Project# JS-2017-002281 Est.Cost: $19000.00 Fee:$75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: TRINITY SOLAR 104144 Lot Size(sq.ft.): 27181.44 Owner: BUSHEY ROBERT D&CONSTANCE.1 zoning: SR(l00)/WP(72)/ Applicant: TRINITY SOLAR • AT: 34 COOKE AVE Applicant Address: Phone: Insurance: 32 GROVE ST (508) 577-3391 O WC PLYM PTON MA02367 ISSUED ON:5/26/2017 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 4.275 KW SOLAR ON ROOF - 15 PANELS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House it Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 5/26/2017 0:00:00 $75.00 212 Main Street,Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner Filen BP-2017-1367 APPLICANT/CONTACT PERSON TRINITY SOLAR ADDRESS/PHONE 32 GROVE ST PLYMPTON (508)577-3391 0 -' PROPERTY LOCATION 34 COOKE AVE MAP 18C PARCEL 033 001 ZONE SR(100)/WP(72)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ZONING FORM FILLED OUT ENCLOSED REQUIRED DATE Fee Paid � Building Permit Filled out Fee Paid Typeof Construction: INSTALL 4.275 KW SOLAR ON ROOF- 15 PANELS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 104144 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFQ$MATION PRESENTED: (/Approved__Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit _ Variances Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management I-••oil ' n Slay Air Sign. Buil.imgy mial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. / DepartmentuseDoty City of Northampton Status ofPennit . Jam \ Building Department ewe CWDrireway Permit 212 Main Street Sewer/Septic Avallablhty I� - - A Room 100 W AvaSabgxyr �- ,/ MEM Northampton, MA 01060 Two Sets of Structural Me -phone 413-587-1240 Fax 413-587-1272 Pbaaiffi Plans � `: / Other SPeci APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Atltlreas: his section to be cco�mpletedd}by office Map_ �l_ Lot ✓ l Unit 34 Cooke Avenue Northampton,MA 01060 Zone Overlay District Elm St District CU District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2,1 Owner of Record: Constance Bushey 34 Cooke Avenue Name(Pont) Current Mailing Address'. 413-584-5107 Please See Attached telephone Signature 2.2 Authorized erg}, Trinity Heating Air Inc a 6 Trinity Solar-Ned Greene 4 Open Square Way-Suite 410-Holyoke,MA 01040 Name(Pont) Current Mailing Address'. J( 413-203-9088 __ $ignatu Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars}to be Official Use Only completed by permit applicant 1. Building (a)Building Permit Fee $ 6.000 2. Electrical $ 13,000 (b)Estimated Total Cost of _ Construction from(6) 3. Plumbing Building Permit Fee 4 Mechanical(HVAC) 5. Fire Protection 6. Total=(t +2t3+4+5) $ 19,000 Check Number 2g7e„, j z This Section For Official Use Only Date Building Permit Number'. Issued. Signature: Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Required by Zoning This column m be fluted in by Building Department Setbacks Front Side 11111111111 Rear Miala11111111111111111111■ Bldg. Square Footage h_® Open Space ii� i��- flur area minus bids&paved whin. Me= 11111.1111. A. Has a Special Permit/Variance/Finding['� ever been issued for/on the site? d1 NO 0 DONT KNOW YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW g YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW 93 YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES © NO g IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO V IF YES, describe size, type and location: E. Will the construction activity disturb(ci acing,grading excavation,or filling)over 1 acre or is it part of a common plan that will disturb over I acre? YES NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House n Addition ❑ Replacement Windows Alteration(s) Roofing ❑ Dr Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [01 Decks [q Siding[0] Other[rip Solar Brief Deserted/tin of Proposed Work Install 4.275 kw solar on roof.Will not exceed roof panels,but will add 6 inches to roof height. Alteration of existing bedroom Yes No Adding new bedroom Yes , J No Attached Narrative Renovating unfinished basement Yes at No Plans Attached RNi -Sheet 6a.If New house and or addition to existing housing,complete the following: a. Use of building :One Family Two Family .,_Other b- Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions a Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No 1 Septic Tank City Sewer Private well City water Supply SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Please See Attached , as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I, Trinity Heating&Air Inc OBA Trinit Solar , as Owner/Authorized Agent hereby declare that the statem &and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and nalti s f perjury. Neil Greene Print Name j X / 65/25117 Signature of �x feer/Agent Date SECTION 6-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisot: Not Applicable 0 Name of license Healer: Neil Greene CS 104144 6 License Number 43 Firgle e Aveibue-Springfield MA 01108 03/17/2018 Address Expiration Date 413-203-9088 Signatur Telephone 9.Registered Home hnprovementContnctor: Not Applicable 0 Trinity Heating&Air Inc DBA Trinity Solar 170355 Company Name Registration Number 20 Patterson Brook Road-Unit 10 10/1212017 Address Expiration Date West Wareham,MA 02576 Telephone 413-203-9088 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.C.182,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit Signed J Affidavit Attached Yes y No 0 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Oweer-occupied Dwellings of one(I) or hyo(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 10845.1. Definition of Homeowner Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official that he/she shall be resmonsible for all such work Performed under the building permit As acting Construction Supervisor your presence on the job site will he required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you way be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner'certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature Trinity Solar 20 Patterson Brook Road Wareham, MA 02571 508-291-0007 Date: 5/23/17 I, Constance Bushey do hereby grant Trinity Solar the right to sign on Mom.o a.nom.) my behalf in all matters regarding the permit applications through the township of Northampton for the installation of solar panels and all other related work on my property at 34 Cooke Avenue . Please accept this document,with full signature,in place of all application signatures.Furthermore, should there be any issues or discrepancies with the paperwork,please contact Danielle DeVito at Trinity Solar, 732-780-3779 ext. 9044 or danielle.devito@trinitysolarsystems.com. Sincerely, Y Q �� G"^ u ""wi 34 Cooke Avenue Homeowners Signature UU ` -" Street Address Constance Bushey Northampton --01060 Print name City,State,Zip Code 413-584-5107 Phone Number 4(77 15= � - /7 ,/ INSTALLATION OF NEW `°°MEF°E' ROOF MOUNTED PV SOLAR SYSTEM N ,i- 34 s34 COOKE AVE, $ NORTHAMPTON, MA 01060 . b , , w�N,Re City of Northampton 4 Building Departmentopiii Plan Review oat viC,+Nm MAP ( .... ''«,--.�.._ .,„.,. 212 Main Street LV"' SITE I"" SCALE NTS IIMM_ Northampton, MA 01060 Nu„N1..cON6..Na 36 KE MET NORtRAMPTN,MA 01060 OS".. m64 PSKPOKirtsc ,,,n ,,,,,u.. CCOM.y avnW.e SHEET INDEX amJm.ae= PV-1 COVER SHEET W/SITE INFO&NOTES "E PV-2 ROOF PLAN W/MODULE LOCATIONS PROPOSED PV SOue!A./STEM _..GENCLIIASEWSIG PV-3 ELECTRICAL 3 LINE DIAGRAM ...Me re ... AP APPENDIX °"" MAWIFIG DATE 1 5/221101, „�� a >9 ..,a..... WE WAXER .ewwo.c-.w SWOT mmmm -- 04 0.13tad\A4 (=REF CIX MIT CCNOUCIT/Irl altOKS M9510 AU An''CM DM, CISCOMMT SWIM, MOTELEFI4SIF LW ARP R�.� P1 PV `1."'"`M.,:.` m ,..r,.m„e.aeeeel. SOLAR • Nona smut.susGyms m ,er a .. III -111 !t4TeDsle:Palfz.„--se-IEN, .... ,. num lii its ,e .e . a_ _mm. no, 54 TTDA „ E°„i:L E.T0..sPF%LTsrmmE.00, DHEIO .nnzOROuPL,Er ETOPEAKOFRo f ieweu/Renebne FRONT o1x,irncx PATE crmdime. Q M EP TENETKTE.m.T.PA,..,m PAWL mem UD 34 COOKE ALL P NORTHAMPTON,MA OIOxo , AC R7 Drawing OPozxo w5040.SYSTEM DAWN inrm.em moms our m,/N„ rHm mm„ennn:N R ■ TOTAL PALCInt MIXT: Is MCC EHISEb: WIWI\HS (.111 in COMPANY: XV%MID i.E m.rv. en. BACK I A NN , BE N. ARRAY SCHEDULEII Norm. n "SYMOOLLSOEN a Nemo„NonANN Ill Nonnno nT.�nPA ��. PLUMBING SCHEDULE EQUIPMENTSCHEMREAi Pl PV 'J ®' o T,m a . PAe. ma.n of �I , en. E OTHER OBSTRUCTIONS ssis 3."! nnity, .us,a .e ,,,x, SOLAR Iti rrELEcTRK&PMEL • El nCManPA.n.m,w„ 'ice REFER Tndw.m,en, .megut a , nrvruouTIta uuHEumMIX rs rs ww •rmun normenuunee Xdfa. on Demsaxi. sa no mecums micia IN 1 15 HOC PM If RPM. 2 LOWEST DOMED MIMIC¢w¢orv,i EASED ON uxueq renurnmewevrarnewTeuu yTnrvn im000n xvner Eay.a 'E' nmreunu rwuw annou MOOT vm"nn To -Q— TIME'WC I la NOS WO/ff FLIMOMIENTAL5 2/1 MI6 hi 2111•Uf[MOW AT aokfl 0 5'ABOVE Rf if if 410!NW 0111 Of UNflED STA res, 6.I 1110TOVOLTIIC POWER SWIM SHALL BE TO()OMR WITH UNGROUNDED NOTOV01.71if wunarnxo oommnxcmiu ram[paaa N Pxyanix uaarvrou EDT[ I "MA HUI NEC2I'AGAIASIOM u.WA' PmJecTmtl7a axmsmvun wIlfrEnNA,Y,A:,wfly0MR,RELECGPILAI:f IT RHE),P15m5FIAAJL.BE RIO MM � " — UMITY pNORTHAV?IT PIACI; MPTON.MP0oz0rvLAmNDS. Drawing . xa. ° nxm.xrs, SYSTEM PROPOSED PV SOLAR 10[FLEXIBLE CONNII 5RALL 110T BE[MAME)ON CPA.SHILL BE LIMITf D TO 1 r If USED "MR VAD!!""r INVERTER II ® cramp'.informacen 705 II I'J POINT oeCONNECTION NEC � n- RINSED af Q e ®. to- my,,m mnnssuCIEh xDC M.uT.m,xePmrt„.,eMoLOre"xT,m TrmIsr", 51 I 2755W MU 705111D[120101 nmEo,xnxnMn LOm..xx,. LO pro ph aemf s 0050 MAMMA INS WPCS NEC 705-12(0) 1.4.P ALLEGUIPMENT INSTALIIP OUTDOORS YOU HAnyrtrOCAIUM116 COMM VE Min METER II f f If 12•1 f. .EDf ,m TmE.,Mno.m ,n I LOSE Imo I 9[1 m l ti wox`:,:'a:: °Ifff.,rexMP1 1 PV — 3 a'ro�ra.ero,ELO6 ,re"e x VI•10 MO 15. OH n e,T a o :oro"; . Richard B. Gordon, P.E. P.C.Box 264•Farmville•VA 23901 Ph: 434.315.5759•E-mail: grichardpe@aol.com May 23,2017 Northampton Building Department Northampton, MA Re: Solar Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. Please note the following conclusions regarding framing structure, roof loading,and proposed site location of installation: 1. Existing roof framing: Conventional wood framing is 2x6 at 16"o.c.with 12'span(horizontal rafter projection) This existing structure is definitely capable to support all of the loads that are indicated below for this photovoltaic project after sister rafters with a 2x6 using (2)10d nails 1' o.c. Use of(2)Guard Dog" FMGD002 screws is approved,or equal shear strength of approx.120 Ib,1' o.c.at areas where little space is available only with remainder of member secured with(2)10d nails 1'o.c. If do not sister,then install a 2x4 @ 16"as. knee wall over an interior bearing wall to limit span of rafters between supports to 10'-10". 2. Roof Loading • 4.33 psf dead load(modules plus all mounting hardware) • 24 psf snow live load(40 psf ground snow live load reference) • 6.2 psf dead load roof materials with knee wall and 7.9 psf if sister with 2x6(3 psf fiberglass shingles,1.5 psf VC wood sheathing, 1.7 psf 2x6) • Exposure Category B, 106 mph wind uplift live load of 16.6 psf(wind resistance) 3. Address of proposed installation: Residence of Constance Bushey. 34 Cooke Ave,Northampton, MA This installation design will be in general conformance to the manufacturer's specifications,and Is in compliance with all applicable laws,codes,and ordinances,and specifically,International Residential Code/RRC 2009. The spacing and fastening of the mounting brackets is to have a maximum of 64"o.c.span between mounting brackets and secured using 5(16"diameter corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter&min. 3" penetration of lag bolt per bracket, which is adequate to resist all 106 mph wind live loads including wind shear. Very truly yours, Integer Richard B. P. . Massac se - L ense No.49993 MECHANI NGIN: ERING CIVIL ENGINEERING ELECTRICAL ENGINEERING H(.P 2� �yG F RGCNARD B �n% F GONDOLA p 0 MECHANICAL V, N': 45544 Q �� f -00NAU ''G ri.1 ® Massachusetts Department of Public Safety Board of Building Regulations and Standards License CS-104144 Construction Supervisor NEIL G GREENE 43 FRGLADE AVE _ SPRINGFIELD MA014111 P-71--n Expiration Commissioner 03117/2018 Construction Supervisor Restricted to: Unrestricted-Buildings of any use group which contain less than 351000 cubic feet(991 cubic meters)of enclosed space Failure to possess a current edition of the Massachusetts State Building Code is cause for revocation of this Scense. BPS Licensing information visit:Y.MW.MASS.GOVIDPS ('/J/ ///(-1//1,/'(f/7/ (j/ (- fi(/.iY( .i(/( //.%(1�/ �g F,. Office of Consumer Affairs olid Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170355 Type: Supplement Card TRINITY HEATING & AIR, INC. Expiration: 10/12/2017 PHIL SMITH 20 PATTERSON BROOK ROAD UNIT 10 WEST WAREHAM, MA 02576 Update Address and return card.Mark reason for change. -' Address Renewal t Employment ❑ Lost Card -Kinky of Consumer Affairs&Business Reggiano,' License or registration valid for individul use only . found.-,HOME CONTRACTOR Office theConsumer onsuner tand Business ssg: ._ 10 lark Plan - AttainSer1and Business Regulation _ -Registration: 170355 Type: 10 Park Plaxa-Snise 5170 Expiration: 10/12/200 Supplement Card Boston,MA 02116 TRINITY HEATING&NIR,INC TRINITY SOLAR 2 ILSMITHP 20 PATTERSON BROOKROADU � ,. : �.. - - - • I WE9f WAREHAM,MA 02576 Undersecretary of valid without signature A�It CERTIFICATE OF LIABILITY INSURANCE 10/31/2016 DARES" °"""' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pollcypes)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsementis). CONTACT PRODUCER W Arthur J. Gallagher Risk Management Services,Inc. 'PHONE 856-482-9900 Ike emx 858-482-1888 4000 t Laurel NJ 08054 wawa& INSORERIS)AFFORDING COVERAGE _ NAICII -. INSURER A:HDI-GFObal Insurance Company 41343 INSURED TRINHEA-03 INSURER 6:Liberty Insurance Underwriters Inc 19917 TRINITY HEATING&AIR, INC. DEA TRINITY SOLAR NEURERCo 2211 Allenwood Road INwIeERa: Wall NJ 07719 - — - INSURERE: " _ . INSURER F: COVERAGES CERTIFICATE NUMBER:2088149375 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED MOVE FOR THE POLICY PERIOD INDICATED, NOTNETHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO V.HICH TIES CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. MR —AWL sumP /EFF PGLWY B%P LTR TYPE OF INSURANCE INN) VWD pgICY NUMBER IM BrYYI I IMI4DOIYYY1, LIMITS A I,x COMMERCIAL GENERAL LIABILITY I EGGC0000065616 11/1/2016 L 11/1/2017 EACH OCCURRENCE [43000.000 T GLAIMS-!ADE I X .OCCUR - _PREMISES RIRO ElOCACe — ... MED EXP(Any toe person) S PERSONAL d ADV INJURY 52.000.000 GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $2,000,000 I POLICY X SECT [ WC PRODUCTS-COMPICP AGG S2000.000 Ot 3: £ A AUTOMOBILE LIABILITY EAGCC000065716 111/11206 11/1/2017 BODILY INJURY(Per accident) F LUMBERED SINGEL LIMIT ERRmaeMl z,uoo.00G ANT AUTO BODILY INJURY1;0'05de) 5 ALL pWNE0 BpLp`SEULEO E MIRED AON,O XIREUAVipS LoosBODILY z2c$R'mM1 {1A6E '5 A 1 UMBRELLA LBW III XOCCUR EXAGC000065615 '11/1/2016 11/1/2017 EACH OCCURRENCE 0,000.000B X EXCESS OAR1000231934-01/ t 11/2016 11/1/2011 -- GLAIMS-MADE AGGREGATE $4,000.000 OED RETENTIONS Limit XDI 53,000.000 E21.000,000 A ,Ll81w KERS UASUTY COMPENSATION EWVocP0000656t6 iViY1016 itittROt1 STTUTB..... 'ER . ... ANY PROPRIETORIPARTNEIVEXECUUTIVE SON EL EACH ACCIDENT £1,000,000 I OFFICERMEMBER EXCLUDEDTNlp (Mandatory In NH) E L.DISEASE...EA EMPLOYEE 51,000000 IIy RIPtION un�I 1 " DESCRIPTQN OF OPERATIONS Wow EL DISEASE-POLICY LIMIT ,SL000000 1 I I 1 DESCRIPTION OP OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,AEtlWoml Remarks Schedule,may be attached lemon Frye M IpuIM1 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Evidence of Insurance THE EXPIRATION DATE THEREOF. NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORZEO REPRESENTATIVE 611988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents E_ fi 1 Congress Street,Suite 100 Boston,MA 02114-2017 • www.mass.govidia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumhers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Leeibly Name (Business/Organization/Individual): TR ltd .. - _• . . . h&A TR lkkt Sef.aR Address: Z 2.11 ALte:SweoD ROA& City/State/Zip: WALL 15.100 sE9SEY 07715 Phone#: -332-780-377'3 Art you an employer?Cheek the appropriate boa: Type of project(required): f 5^ 1 am a employer with 1 203 employees[full and/or pan-time).• 7. 0 New construction 2.0 lam a sole proprim««pmmenbipand have noemployees working for Tee in 8. ❑Remodeling any capacity(No workers comp.insurance required.) 0 3Q 1 am a homeowner doing all work myself(No workers'comp.insurance required ' 9' Demolition ) 4 0 an a homeowner and will be hiring umuamom to conduct all work on my property twill 10 Building addition ensure that all contactors either have workers'canpmamion insurance or are sok II.�Electrical repairs or additions nopretors with no em$Gyees. I2,0 Plumbing repairs or additions 5 I am a general contractor and I have hired the sub-contractors listed on the attached sheer. Dime sub-contractors have employees and have workers comp.insurances I3.0Roof repairs Thes 6.0We are a corporation and ILSofficers lave exercised their right of exemption per MGL e. 14.DOther 152,§l(4),and we have no employees.[No workers temp insurance required I `Any applicant that checks box el must also fill out the section below showing their workers compensation policy information. t Homeowners who submit this affidavit indicanng they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. :Canuamon that check this box mum attached an additional sheat showing the name of the subcontractors and state whether or not those entities have employees. If the wbcpnnm:sms Moe employees,they must provide their workers'comp policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: HDI-Global Insurance Company Policy d or Self-ins.Lit.#:EWGCC10006516 ,,,,,,,,,,,, Expiration Date: 11(1/2017 lob Site Address: 9 Pend Seuhte WAY Su rrF 14 10 City/State/Zip: HOLYol,E., MA OiO.ktO Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MOL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the vi later.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verifies ion. Ido hereby fy under pains nettles of:doa that the info h in provided above is nue and correct Signature: 4 Date: tl- 4-at5 t6 Phone • 0 -377• Official use only. Do not write in this area,to be completed by dry or town official City or Town: Permit/License# Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: p��•q, ~4Ecolibrium Solar Installs easily; t. provides fully integrated grounding and bonding with its proprietary module clamping Ecolibriumsolar.com components EcoX is an innovative, simple, and easy to EcoX Features& Benefits install flush-mount solar racking system. By eliminating the mounting rail, EcoX offers a • Certified to UL2703 flexible system layout and streamlines the •Certified System Grounding and Bonding via installation process. module Clamp and Coupling Assemblies EcoX utilizes aluminum components with • Load tested to UL2703, Section 21 stainless steel hardware, ensuring the system • Rain tested to ICC AC286-12, Section 4.1 will withstand harsh installation environments, With EcoX, the racking and modules work •Certified for use with approved 6o cell modules together as a system, creating an •Class A Fire Rating (with or without Skirt) interconnected, continuously bonded structure. f xrzz LISTED Nreollxni US Office: Email: Sales@EcolibriumSolar.com Telephone: 740-249-1877 fitor nielMO cuss- 111111 Aesthetic Design Cable Management A wide range of adjustment makes 7t easy to install a Whether installing with Microinve;tern,Power straight, level system. Components are designed to Optimizers, or String Inverters, EcoX provides wire blend into the array, and the aesthetic skirt creates management provisions to both prep the modules,and a finished look. Alternatively, a skirt free option is to route homerun or trunk cables throughout the array. available to provide a more traditional lookv LLA Layow I Flexible System Design Single Point Grounding The EcoX Estimator is a powerful racking system EcoX and approved modules create a continuously design tool The use inputs ail site conditions and bonded system. The installer can connect a finished can layout multiple roof surfaces. The EcoX Estimator array to ground with a single bonding lug_ outputs a site specific design package with engineering specs and bill oFinaterials. Technical Specifications Racking components:Aluminum, stainless hardware,dark Materials bronze anodized upper surface,mill finish lower surfaces Fleshings:Aluminum,black powder coated finish Grounding/Bonding Validation 11L2703 - see installation manual For specific module approvals Fire Resistance Validation I UL2703-Class A,Type 1 and Type 2 modules Mechanical Load Validation 'UL2733 -see ossttaeion manual For specific module approvals Flashing Validation ICC-ES AC2146/UL441 Rain Test for Roof Flashing 11" vertical range,3.5" North/South range,Adiustabillty connect anywhere in East/West direction Warranty 115 years saIes[aecoitriurnsolarcmn US.?4O-249-1877 +wnuecoibrium oIarcom W EColibriumSolar V Ecollbrium5olar 4. Install Attachments to Roof p positioningFlashing to Shingles Gap between Shingles I When correctly 4d Properof completely covered Remove nails positioned the Flashing correct:Do not leave lV� by Flashing as needed for J' will prevent water a gap between Shingles ! � clearance •_- Il damage to roof from not completely covered water seepage and/or by Flashing freeze/thaw cycles. •r Best practice is to Trim notch in I - position the Flashing Flashing is r s , shingle to „ mounting hole 2-1/2" aligned with clear Base • up from the bottom downhill edge`{[` ! — I edge of the shingle of Shingle fit, • s • course.This pads the ° q \\ • 2-1/2" Base Flashing the edge of cor ect: flush with the edge of Incorrect:Do not allow I the shingle course'Its to Flashing extend mounted on. below the downhill It is acceptable to shift a "`LLL edge of Shingle Flashing uphill on its _� _ ._ _._ -- --__-- shingle course and to trim the uphill shingle to Positioned Incorrectly Positioned Correctly Acceptable Position clear he Base. (when necessary) 4b. Drill 3/16" pilot hole re -NI At the attachment 4c. Apply Caulk to Flashing Apply a horseshoe ...--repo. ii locations drill a 3/16" shaped generous bead pot hole at a sufficient of caulking on the roof Drill 3/16" depth to fully secure the surface or the bottom of y Pilot Hole Lag Screw and Flashing the Flashing with the to roof. Bottom opening downhill.Start Side of and end the bead near � F t Flashing the Flashng's downhill / CAttachment lil 1 u.ly a�nk �.� edge. a SC--.-- --- ///� Location � " ,nl Il,d t t oirrum. 0 or wnura i Horseshoe s'- I- a. r . s nui shaped Caulking Corner of Array IhiL Downhill Eco%Gena Installation Guide,Rev 1.5 8 of 31 Ecolibriumsolar 4. Install Attachments onto Roofffront.) 4d. Place Flashing, r 1 if necessary,clearance Be sure to orient the 0.7 �/ / ',� trim the up-course r __ Lag SCrew wfth �n Base as shown with its Slide Flashing �/C \, Shingles to clear the l - Sealing Washer offset mounting hole under uphill course- `, Use,Flat Roofing Bar ' Base. ,_ "� -- directed uphill on the of Shingles to lift uphill Shinglesk Line up the Flashing's _ Skirt row the Base can ' '^ "^ mounting hole to pre � -{ O, be rotated 180 degrees / drilled pilot hole and — SN r� which helps hide the \ s square the Flashing to IN yY Base behind the Skirt '^v the shingles Base (see examples belowl. �� '� Install the Base using Adownsl The pe d •= the Lag Screw with its , iii dow slope edge of _ pre-installed Sealing ex FI Hng must not —� �`� Washer.Drive the Lag extend beyond the If needed, �� Screw into the roof „.., , \ m - of Shingles that Notch r Base structure securing the Align with Pilot ii s attached to. too r Base. --�� Base and Flashing to the Hole/Chalk Line - roof top.Torque to 14Lft-lbs.to ensure seal. _iiiiiii __ _ __, �\ \ 0 Torque to.14ft.lbs. Base Positioning - Skirt Row _vs other Rows i Uphill -Ji 0 pF IEI, 1 fil Base can be rotated 360 degrees to Skirt row Base Position Standard Base Position allow adjustability of Clamp position. It's recommended to rotate the Base so its Offset mounting hole Rotates around its offset mounting hole. offset mounting hole is downhill. is uphill. This helps hide the Base behind the Skirt. Eco%Gent Installation Guide,Rev 1.5 9 of 31 U Ecolibrium Solar 5. Install the Junction Box Bracket 5a. Attach Bracket to Base with Self Drilling Screws Bracket can be flipped Base---,....,• for height adjustment ' 0, i., i Elevation of Bracket 2 r{, to Base can be e Flanges Bracket ! anywhere within S pointed this range upward Base--\ a z . X14K rtl u x > x r y" �;* � 7------ - BracketJJq rg� ao-v er-iifinction Box il Ju w « The Junction Box� Brackens attached to the Base with Self ffr„ c Drilling Screws Ysr g v , f Selectone of the #14x1"Self Drilling Screwg `Yb -� previously stalled (3-placesh,a^l0 s 'a Bases in a location `1 suitable for mounting the Junction Box and install the Bracket as - shown. i e.. ,`1 �.. Torque to:loftlbs. �,� '. k 1 Universal Mounting Slots \^ The Junction Box can 6e secured to � V the Bracket with Self Drilling Screws 0 Uphill 4 O or by utilizing the Universal Mounting Slots along with 0 appropriate attaching hardware. EcoX Gen2 Installation Guide,Rev 15 10 of 31 i 1 Enda:MumSole Appendix F. Installing the Skirt-Less Clamp Assemblies 1a.How to Set the Clamp Assembly Height via the Glider Height settings are - , made by utilizing the 5-postion dovetailed engagements of the 1"range of adjustment{1/4"increments} Glider-to-ease,The Clamp Assembi �� y between High&Low positions image to the left shows three theseof positions Jin<ludes Glider} i'rangegeofof trtravel is III poremeit,Th Giider--v,� ncrrJrle ari Th' quates " 1t 1I8"vanat'o from i to adr in adjacent Glider Align Highest- .J ,,��--Align Middle Align Lowest to adjpsiment and setting Mark ! Dovetailed setting Mark setting Mark 1 corrpensaie for irregular ofGlider to of 1 of Glider n6 roof tops t Engagements I o"undulating top of Base i change elevation I top of Base i top of Base ng 1 Start try setting the the iy in i/Q'increments l 7 Glider on the endro4 1 1 Base is �`''" " l I mroid to pus to -arid P Clamed along to level e wa Highest Position Middie Position Lowest Position needed m level the tow — {start here) 1b, Install the Camp Assemblies Set Glides at Uphill edge Acceptable range Align Approx. of Glider for uphill edge R 1 inch of Glider Engagements and - 1 Start in Slide onto Base I Middle Position 1t:b. a . Glider 41 i 1 • Alignment �r ij - 1 Marks - $ r Two vacant slots at Tap ' . Bider Two vacant Setting Marks: - slots at —..! s Lowest Uphill Bottom Base Uphill Middle ft' � 0 Highest Thi 6gdxuatigned L outside of the acceptable range and must be repositioned. EsoX Gent inrtzitation Guide,Rev 15 H s^'a8Pa.le/os 14441 i3ag51 >JNv1U3N13N HI-vpbNLs/)b-yNIHJ-Nvevt iSMbb. ' ARYL -, Q};t an °pPeileuu JarsNV`e3eP aPe38 anu "sn MuA u 1:::4»!M les PaaJ asse-4'a . A sM1a 'Sala:MI J° MIB� a l aLdnyl d8 JMn Adb adtuZ' 4 JOAPunuotzIaL Pup Joo i .. xu sept% .1 ifewv =tom �P,'N °uo rywru �ollueut aditi, • :"?au'ae,- 33 a3sds pa14eua a8p3 dos d,%8e my„ �e°"sjui . a!e • au • It a ;- yh t}i �'n . S U � � • u4 > 7o0_00-t gs gn_ oe/Sn700093SSn-V00Ylt3S sn e000s3sisn °oss3sisn booasm e3Saaua� � asa ,n7 yd osia a�6u►S a6p3a °S solar " • • c Single Phase Inverters for North America SE3000A-US I SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US SE3000A-US Sf3SWA-U5 SE5000P-US Sff000A-05 SE7600R-Ug SE1Y000A-US SE11400A-US OUTPUT N. al AC Power Output 3000 3800 5000 6pW )600 9980@208v 11400 VA Max AC Power Output 3300 9 4150 1500)@2UBV 60W 6350 10800@208V 12000 VA 54502<N 10950 e240V AC Output Voltage Min Nom-Mm'- 183-208-229 22g vac 1 i J J - AC Output Voltage Min•Nom Max n"' i 211.240.264 vac J J J J J 'r I AC Frequency Mm.Nom.-Max' 593.60.605(with Hi country Setting 57-60.60.5) H) j 24@208V ' 48 60 208V MaxRonnnuous Output Current II.5 16 25 3.2 47 5 A 21@240v I 42@240V I , GED]Threshed 1 Utility Mnn m,:1g IflandingProtection.Country ConfigurablThresholds _ ves ; .e:_ INPUT Maximum DC Power:5TCI I 4050 7 5100 I 6750 8100 10250 7 13500 ' 15350 7,—VI Transformer-less.Ungrounded Yes Max Input voltage 500. . . . . . . . . vdc.. Nom.DC Input Voltage 325 @ 208V/350BD 240V Vdc Max Input Current 9.5 I 13 16.5 RE 208V 18 2333@208V 34.5 Ads 15.5 @'240V 130.5@200V I Max Input Short Circuit Current 45 Adc Reverse-Pnlarty Protection __.._ _.. _. Yes _.._... i_.. Ground,Fault Isolation Detection J 600ko Sensitivity Maximum inverter£M cY 977 98.2 98.3 I 983 l 98 98 98 Y CECW hid Efficiency9J.5@208V 9)@208v • 8 97.5 98 98@240V • 975 97.5 1925@24UV 97.5 b Nighttime Power Consumption 525 _ _x4 _ W -__ i_ . ADDITIONAL FEATURES Supported Communication Interlaces R5485,RS232,Ethernet,ZigBee tophenal) _.. _. .. Revenue Grade Data,ANSI CII.1 Ophonal°' Rapid Shutdown-NEC 2014690.12 Functionality enabled when SolarEdgerapidshutdown kit is installed' STANDARD COMPLIANCE SafetyoULI)41 UL16998 04199.8 CSA 222.. ,. _... Grid Connection Standards IE6E3547 Cm2sOn5L FCC pa rtly class B • INSTALLATION SPECIFICATIONS _ AC output mntlult»a/AWG range • 3/4"minimum/]66 AWG 3/C m /83AWG OC input conduit sire Y e/ of Aringsl 3/4'mrnimum/1-2 str]ngs/16.6 AWG 3/4'minimm/]-25lrings/ AWGrange14.6 AWG _. . . _ _ .. DimansiOm with Solely Switch 3057125n10.5/ ml 30.5012.5x22/7)5 x3150 184 _ eigx0w. . 775 x 3/ 0160 mm Weight with 5aIe1y Switch -,i... 512/233 I 54.7/24.7 88</4 40.] ! Ih/kg • Natural - convection Conroe Natural Convection and inFans{userreplaceable) • r ran liner Norse r25 550 dart MnMrnng-Max Deflating -13 to 5140/-25 to c60{4010 060 n available-IRae 'F/ C Pro ecnon Rating NEMA 38 Eapt3= RoHS solar • • • = N SolarEdge Power Optimizer 2 Module Add-On }-- P300 / P350 i P404 / P405 / P500 0- CC UJ ta xya Q PV power optimization at the module-level • Up to 25%more energy • Superior efficiency(99.S%) • Mitigates all types of mottles crosmatch4oss,from ma-rummer ag tolerance to partial shading • Flexible system design for maximum space oniitanon Pi Fart innatfanon with a single bop • Next generation maiplenance with module level monno-lng . Module lave voltage Shutdown for insta9er and 5rehghfer safety __. 1 .. v.. . ^In•err, solar " • • SolarEdge Power Optimizer Module Add-On P300 / P350 / P404 / P405 / P500 P3® P350 P500 P400 P405 )for 60-cell Itor high Power for 96-cell for 60-cell for thin film modules) 60-cell and for modules) and 72 cell modules) 72cellmodules) short strings) _. . INPUT RNcd sir I( >.mC 300 1 _.O 4O5 d0i +050mar re.5 mi:Vbags. ES r FG 90 lL Noon arty. mc.e..rC L_ F _orRIP .en{.c 8 a. 8 CO 8 Bn 12.5.5 :2.5 305 .nc rAn.m.aL aivw'Cunt r. IC 11 101 Ad[ L ar�x, [(ry:n er 99.5 [hbc Cr'xr, 988 r1.Cr., JF C!H-Cry OUTPUT DURING OPERATION)POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE IN VERTERI 1.a+i. n.Oclpu:Cu'ren. IS .a_ DC:Anun Cru t[sit vol lage 60 R5 Vcr OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Ss'ety Culou c [age per IOwe'P6nm aer .Cr STANDARD COMPLIANCE FCC F0115Class 011061000-6-? IFC610006-3 EC62i 09-1 lCiasz'.I 3.7'etvl.b:I2di ^cH y Ye• rnr Snle'.Y VDE ARS 2100-712201305 INSTALLATION SPECIFICATIONS Maa.^uo dllav,rr.yrslem Vc Fr 'AGO Vdi 2-.. .2x275/5 S9'• LOS 128r 152.35/ 128e 2�2..r ' 126.IS? SCI ni 5x5597*1.37 5r5.F7r16° 55)97.196 nc ad�pcablop IfiU/17 830/26 99d/2' 1064./23 ri/R .v ncr VI MCd Oi ryp rarnector MCd L LRnn L:•rr0. 15. 12/39 n. . > P1arg Tr p e .r r .c rn _RS i d0 _55 C Prcnon RPCP/NEP A6r +. nra rvun nq 0 100 FV SYSTEM DESIGN USING A SOLAREDGE INVERTER SINGLE PHASE THREE PHASE _i . . . g1enRtH P3Gfp3SCPS( 6 8 IL P4CC P405 6 .. r n ^ Sv'nsire.t,IPuw.er Op±mrzu 51 .an e^r Pewrr ee'Slr cB 450 1250 ae�c Si c, . .t, nIlonotha o,Oncnuoc.z Yes powered by Q.ANTUM _ti i t i Q.I\ EA LK=�G4 i1 285=295 Q.ANTUM SOLAR MODULE The new high-performance module - is the ideal solu- tion for residential buildings thanks to its innovative cell technology . The world-record cell design was developed to achieve the best performance under real conditions -even with low radiation intensity and on clear, hot summer days. 0(-"'A Y,ANTUM TECHNOLOGY:LOW LEVEUTEO COST OF ELECTRICITY �' Higher yield per surface area and lower BOS costs and higher power classes and an efficiency rate of up to 18.0%. t, INNOVATIVE ALL-WEATHER TECHNOLOBn Optimal melds,whatever the weather with excellent tow-light and temperature behaviour. r�,, ENDURING HIGH PERFORMANCE Eii Long-term yield security with Anti PID Technology', Hot-Spot Protect and Traceable Quality Imo'. EXTREME WEATHER RATING CREAMS High-tech aluminium alloy frame,certified for ttwaaaamrv' high snow(5400 Pa)and wind loads(4000 Pal. • a MAXIMUM COST REDUCTIONS 0 Up to 10%tower logistics costs due to higher module capacity per box. VDE I l r Ph Man 1 © o A RELIABLE INVESTMENT +sty Tia *OWq Indus/ye 12-year product warranty and 25-year linear _ _ yurrewitaarr 411110106performance warranty'. io 6 m merse, APT test conditions Cells at.15004 against grounded.wdh conductive metal top corned rnodue sunace, Pet 16ah Sen data sheet on rear for further THE IDEAL SOLUTION FOR: mt«ma+wn. animal 1610mm a 1000mm x 32mm Onnudmg tramel _ 41.4.11. —_. . . we Rn 18.843 1$05 tnr 3.2mm tnelnICIr pre stressed glass whh II - r`air •'sem ant-rellecton lechnmOge II r Bath Cove Composite 11 1I ri .� ,�... _ — -_-m II.,.J Fame Biala amctl lour II - "1O Lea 6 x 10 msncenoeylue Q.A NUN sol a.cells loan aa bc, b /door vIII 40 - a 15d9a-m IcO )ion Cd P67 With 0yca59 does I I1 Cable a m Sc'a sable I 1000 mm. a 1000mm '� II CenmAiry MviF{ontxl MCII.y MGd m?ermat<apie.-008 ' POWER GLASS 185 290 295 MINIMUM ifRNRAANCE Ai STANDARD TEST CONOtTCCieS STC rPOWEP 761ERANCE 45W f-OWI Pon(at MPP P_, 28$ LVO 295 Seel Court Count Iso 9_45 9-63 970 5 open bran V Ptne V• 3891 39.19 3948 y CuvuL, anl MPP' , El 98 9.07 9.11 Vawe<atMCP Vat 3113 3).95 32.19 Eft venal' n z'7.1 ?114 3177 V NIM414 pLRFORwAACf AT 408MAE OPERARNC COFO1?1ONS.NOC' � r Al Power et MPP ?Pee, 210.7 214 2:6 ^ .: lM 5 Shad cram Conlon yr 771 Z» 782 T 6' open f,muiL Vorzafe- VF 36 18 3665 36.92 W Collet al MPP' In 704 7.12 720 ,f I�. V ltage at MPP" Vxn 2592 30.'.2 30.30 tel} LO m,e:C sse_.m Rv I SO MeaSaddes.101flor-05 SIC a 3%.NO x51 B44 a NI%..aced-Jr AM _6 11i>rta re ser cess salsas "sr 0 CELLS PERFORMANCE WARRAW 4 PEREORMAMGE AT LOW NeRAOIANCE M least 985,of nominalpo.e'au,+g f "v i - ,41 Ytar.ilx, O.0%0334. •... :..•: n xr ri _ _ ` At l 836 A 324v,1110M COI P9499 0949 .09 9 nI nom nal coax Go 9 Oy -- m. • 5n es ma me ew craps sat m of ywr rtsoKfYe Counts,. hada mili0esrn u.0 per 0 era rt.I r1V 9C 6 '2 C.'.00:VL¢} TEMPERATOR£tOEFEICIEMTS Temperawn Coefficient of I, a (%/ J 40.04 rempelamre Caeftenm et V. 0 MAI -034 t Temperature Cean,crwl ai?or V t%/KI 039 Nara*Optntiaq Cell Temoua1e< MOOT rd1 d5 Manmvm Sttsm Wattage V66 01 1000 aafety Clots T Cs Maximum Reanu Lunar' I. IAl 70 Ore Rawl/ C W duff Snow Load IPai 4000!5400 Pinioned Meddle ltmareatmx 40t ok e85'C int wtl 1149C9011011941 4+4010.t tu$5On Cantlnutlpt Outa QUALIFICATIONS AND CERTIFICATES PARTNER VDC OwRy Teateo,IEC 61115 fEa 2) IEC 61730(Ed El.appucevon nns A 61140t stem damp i es wee,G4 EN 50380. •f ayeC E NOTE stus ., xe4.SE ma-si8souat .or eoperas" C,ract nu le. .0 se dspa.Tent .mule . a an o'approved ate al on m a .me o'As Gmcsm Hasselll 0CELLS iib) 5onre.'alle.17.Il.0 '66 maeeu$Mallen-Orman iTEL.<910i349a be 99-13444.Paz.49(0,249e 009922000'WAG toeed9/es 0rs l W@ woo a tea wm v. May 25,2017 To: Inspectional Services From:Rachel Bruso—Trinity Solar Subject: Permit Applications for solar installation Attached please find the building and electrical permit applications and all of the other necessary documents here.There is also two checks enclosed for these applications. If there are any questions, please feel free to let me know. Thank you very much! Rachel Bruso Rachel.Bruso@trinitysolarsystems.com 413-203-9088 Ext. 1511 Trinity Solar 4 Open Square Suite 410 Holyoke, MA 01040