32A-065 (3) 63 UNION ST BP-2017-1040 cls#: COMMONWEALTH OF MASSACHUSETTS Mao:Block: 32A-065 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2017-1040 Project# JS-2017-001789 Est.Cost: $37000.00 Fee:$75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: llse Group TRINITY SOLAR 104144 Lot Size(sq.13.): 6359.76 Owner: WOOD SAMANTHA zoning: 31R(4100)1 Appttcant: TRINITY SOLAR AT: 63 UNION ST Applicant Address: Phone: Insurance: 20 PATTERSON BROOK RD UNIT 10 WC WEST WAREHAMMA02576 ISSUED ON:3/20/2017 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 10.24KW SOLAR ON ROOF - 32 PANELS **approved per engineering** POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Numbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House it Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Finah THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeTvpe: Date Paid: Amount: Building 3/20/2017 0:00:00 $75.00 212 Main Street. Phone(413)587-1240,Fax: (4 B)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2017-1040 APPLICANT/CONTACT PERSON'iRINrtY SOLAR ADDRESS/PHONE 20 PATTERSON BROOK RD UNIT 10 WEST WAREHAM PROPERTY LOCATION 63 UNION ST MAP 32A PARCEL 065 001 ZONE URC(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICAT(QN CHECKLIST ENOL• ED REQUIRED DATE ZONING FORM FILLED OUT / Fee.Paid l` ^/i�' Buildin¢.Permit Filled out -�l ' l Fee Paid ✓ Ty eof Construction: STA L 10.24KW SOLAR * i _ SOF-32 PANELS, .rl• H� New Construction i k„ N r Stru tura)interior renovations A "����, Ard ati Addition to Existinr S�y� Accessor Struct re 7 Building Plans Included Owner/Statement or License 104144 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOR ION PRESENTED: pproved_Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER§ Intermediate Project: Site Plan AND/OR Special Pennit With Site Plan Major Project:_ Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special PermitVariance* _ Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW _Water Availability _ Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management —4117/./S> Signa-. of :n....rig Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGI..40A,Contact Office of Planning&Development for more information_ ( Departrnent use only \City of Northampton Status of Permit (L0 /Building Department Curb Cut/Driveway Permit 212 Main Street Sewer/SepticAvailability Room 100 Water/are Avaitabiiity Northampton, MA 01060 Two Sets of Structural Pians "' phone 413-587.1240 Fax 413-587-1272 Plot/Site Pians Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: Tide section to be completed by office 63 Union Street Map Lot Unit Northampton. MA 01060 Zone Overlay District Elm St.Dlstrtct CB Dtstdct SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Samantha Wood 63 Union Street,Northampton,MA 01060 Name(Print) Current Mailing Address- 413-883-2883 Please See Attached Telephone Signature 2.2 Authorized Anent Trinity Heatin. &Air Inc Oil rinl Solar 4 Open Square Way-Suite 410, Holyoke, MA 01040 Name(Print) Current Mailing Address: X A 413-203-9088 Signature �, �� Telephone SECTION 3-ESTIMATED CONSTRUCTION COST$, Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building $ 11,000 (a)Building Permit Fee 2. Electrical $ 26.000 (b)Estimated Total Cost of Construction from(6) 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection pp 6. Total=(1 +22(3+4+5) 37,000 Check Number p// /S 76 This Section For Official Use OnlyOate lVJ Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information _®® Required by Zoning This column m be filled in by Bteldmg neFarcae t Lot Size --- Setbacks Front Side 11111111111 Rear Open Space Footage -11111111.1-__ (1..01 area minus bldg&paved arkint Fill: -11111.11111- (volume&Location) A. Has a Special Permit/Variance/Findin ever been issued for/on the site? NO CJ DONT KNOW V YES 0 IF YES, date issued: IF YES: Was the permit recorded at the€75 YES of Deeds? NO O DONT KNOW €7 YES 0 IF YES: enter Book Page and/or Document # B. Does the site contain a brook, body of water or wetlands? NO Q5 DONT KNOW O YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO Q5 IF YES, describe size, type and Location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO lrJ IF YES, describe size, type and location: E. win the construction activity disturb(clearing,grading,e vation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION S-DESCRIPTION OF PROPOSED WORK(check all applicable) New House f( Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs IC] Decks ID Siding[Cl] Other Solar Brief Description of Proposed Work Install 10 24k solar on roof.Will not exceed roof panels but will add 6 inches to roof height.(32 Panels) Alteration of existing bedroom Yes J No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes J No Plans Attached Roll -Sheet 6a.If New house and or addition to existing housing,complete the following: a. Use of building :One Family Two Family Other b- Number of rooms in each family unit. Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h, Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well, City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Please See Attached ,as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signal re of Owner Date I, Trinity Heating&Air Inc DBA Trinity Solar , as Owner/Authorized Agent hereby declare that t a -atements and information on the foregoing application are true and accurate,to the test of my knowledge and belief. Signed under t e pains nd p-nalties of perjury. Neil Grea. e Print Name 0 X 0111U110 Signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable 0 Name of License Holder: Neil Greene CS 104144 License Number 43 Firglade ven e, Springfield, MA 01108 _ _ 03/17/2018 Address Expiration Date X " 413-203-9088 Signatuy' Telephone 8.Registered Home Improvement Contractor. Not Applicable 0 Trinity Heating&Air Inc DBA Trinity Solar 170355 Company Name Registration Number 20 Patterson Brook Road-Unit 10 10/12/2017 Address Expiration Date West Wareham, MA 02576 Telephone 413-203-9088 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(MAL,c.152,§25C(8)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit Signed Affidavit Attached Yes 'j No..._. ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor,CMR 780. Sixth Edition Section 108.33,1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or harm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official that he/she shall be responsible for all such work performed under the building permit, As acting Construction Supervisor your presence on the job site wig be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,von may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature_ Richard B. Gordon, P.E. P.O. Box 264•Farmville.VA 23901 Ph:434.315.5759•E-malt:grichardpegaol.com March 15,2017 Northampton Building Department Northampton, MA Re: Solar Electric Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. Please note the following conclusions regarding framing structure, roof loading,and proposed site location of installation: 1. Existing roof framing: Roof 1: Conventional wood framing 2x6 at 16"o.c.with 91A"span(horizontal rafter projection). Roof 2: Conventional wood framing triangular 3x6 at 26"o.c.with 11'_2"span(horizontal rafter projection). Roof 3: Conventional wood framing 2x6 at 16"o.c,with 5'.5"span(horizontal rafter projection). This existing framing structure below the residence roof is definitely capable for this photovoltaic project after sister of roof 2 rafters with a 2x6 using(2)10d nails 1'o.c. Use of(2)Guard Dor FMGD002 screws is approved,or equal shear strength of approx. 120 lb, 1'o.c.at areas where little space is available only with remainder of member secured with(2)10d nails 1'o.c.If do not sister,then install a 2x4@ 26"o.c. knee wall over an interior bearing wall to limit span of rafters between supports to 6%5"for roof 2. 2. Roof Loading • 4.33 psf dead load(modules plus all mounting hardware) • 24 psf snow live load(40 psf ground snow live load reference) • 6.2 psf roof materials at roofs 1 &3,7.05 psf with knee wall at roof 2 and 8.75 psf if sister roof 2 rafters( 1.7 psf 2x6,255 psf 3x6, 1.5 psf Ye wood sheathing,3 psf fiberglass shingles 1 layer) • Exposure Category B,106 mph wind uplift live load of 16.6 psf(wind resistance) 3. Address of proposed installation: Residence of Samantha Wood, 63 Union St. Northampton, MA This installation design will be in general conformance to the manufacturer's specifications,and is in compliance with alt applicable laws,codes,and ordinances,and specifically, International Residential Code/IRC 2009. The spacing and fastening of the mounting brackets is to have a maximum of 48"o.c.span between mounting brackets and secured using 5/16" diameter corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter&min. 3" penetration of lag bolt per bracket,which is adequate to resist all 106 mph wind live loads including wind shear. Very truly yours, Rlchar.gr,rd• P.E. " < Mas, _ E.License No.49993 . OySta CF444 Mechanical, Elec.rical, &Civil/Structural Engineering as' \'y$ 4Cqy . f RfCHARO a w . O GORDON m 'NECHMACAL 1 ..t "ryhrTi:RE� At unity. SOI_AR HOMEOWNERS AUTHORIZATION FORM Samantha Wood (print name) am the owner of the property located at address: 63 Union St (print address) I hereby authorize Trinity Solar, and their subcontracting company , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. This authorization includes the transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Customer Signature: w Date: Print Name: Samantha Wood frea L< %Y4 eitl^CSVee-e 3 go _//-7 City of Northampton a �� '� y Building Department 1%//�- " Plan Review 212 Main Street Northampton MA 01)60 INSTALLATION OF NEW ONION STREET. ROOF MOUNTED PV SOLAR SYSTEM ; N 63 UNION STREET `t f NORTHAMPTON, MA 01060 , � g '\ uuei wa.w g � .ppm pmm VICINITY MAP SITE 0' DESCRIPTION DATE SCALE:NTS purled Tdtle. WOOD,SAMANTHA 63 UNION MEET NORTHAMPTON. OMEWL.o.e= GEAPA.. TES� E� "VE" " .. � „nag{ o„.n,mn" SHEET INDEX lle PV-1 COVER SHEET WI SITE INFO&NOTES • maN,ruoToso M "E PV-2 ROOF PLAN W/MODULE LOCATIONS PROPOSED PV SOLAR SYSTEM 11.000.3000 PPRP ""C ' PV-3 ELECTRICAL 3 LINE DIAGRAM P "E NSTPPLAMCnNTRACT°''5 E... FASED TO INDICA,E ..EL AP APPENDIX DIPMIng 311011.311000 3 11.INSTALLATION LMITRACTOMS P030,013.SYSTEM SIM.PP 4 PIMP{P.M09 MIAS{FOE N PIT, UNVERSTANUM.I.00m11.109 1,000 RP PRIOP MI 13.9.4 000N THE NSTALIATION IT PRPM PO ME IMPIMMTIMM..PDE a ,PROMMw POUPPAPTPORIS PM{R(000[13 TOM, PHOTO,MM.MP 00 OVER 0STEM COMPCNEXIM F'°Ce""S St!'""W F'A+C 3PF 3{{3P FIPMPL."3. MC PM MANYI CMOS!M 010001 MVP MWER .103{(1100 1{33030(M CB COPIEME9 POO U01 MILS 55 OTHERMSE INDEATED O ShEpal TO SOT TUM Op MINSTALUDIOLLOMPOMP P0{001PrE 3M°{3.33°°°{3 MD 27„PT.P.e,d �.� ��"PP P1 PV J M'CH MAY COMM 110,0 5 S1MAN HEREIN 7 AMP,COWCPIE NTS TOES PE IN ACCOPOMPE MI pp „ 013.0 pnim SPECIFICATION{ ,"P0�"a.EPM�,."�Pm sw05,"eANP� E . " ,� nity® SOLAR _•raoi_ :ax�._a.... ii i . a:.. �� iX�� Jf F :..,w. s. .� ,..........�. ,.......�.. ..,,.E..u,...........� ._ nEEEortxnEmx.. K. Osn".PMa.,a�.ETAIL �.,�,:� ,o...,.�u.�a C7"Mwop.nAcHMENTON ASPHALT SHINGLE Orr.RO OOUADLELTQ PE"OFECO. NO OESCRIP71014 DATE PrOjeCt NORTHAMPTON, o�s.M, ■ ■ LIIRE:0,■ PROPOSEow,oaw,.,.EM p Ill" ill III 11111.1 0 COMM P 11■■■■1■■ ■1■■■1 no ©® Rth.NE. MM.W.w. ..,....EEA.M MPARAY SCHEDULE SYMBOL LEGEND .,� V P1 PV - 2 „WRINGSCHEDULE EQUIPMENT, o ._.. n ...., z. GWINA"/1100530 HOEHN. MAW CIRCUIT WINNA NOM . I)WHAM MUMMA PAWPAW All!WOW MT riwwmmsrtxmnrwnm¢ngvnewmox IS ADE wcru STRING .w.re MINIMUM MEIN EXTREME NIT 2 SWAGS w n xaminxv MP E WO x... :01 RM.[M10RWPPAV.FId..,iONMA omnnno Wx[.4X -_c .. ,. ,.. rrox omwe N •2 SOWS a.c�ue.EDW..wx. SooxemAII —O m. — _... 3 I WISH LOX MAWR WHEW HAMRA MA RINE ll MN insv.d INDRAWN THE MINIM• DE SIGN TEMPERATU RE CP OA OR LIM Ha OP UMW BEATEN SI AI OMEN MOMS INSTILLED ON ORA ROL DODS AWL INCLUDE A MAD MUMMY&PLINDIAN NNW xi BADECEBESEIRE AEA cm, PERNOTOVOLEM POWER SIMEMMAIN BE PERMUTED WOOD,SAMANTHA ANIMA LE WI X ME FOLLOWING OUTREACH "MAI"AAAAAne"D RED Ee Su,scow I MARIANO SW AMAIMANDLIODIRS MALL BE MO NA EXISTING ZOIA BMW S,�TRTW�rxxsmRWE�ax, O• TWA NCSHALL ��x...EXwC�I„ .oa,HAMPTati.TR.o1o� I4 OTHERWISE SONO .I.,.,R.A,w UNLESS �, Leman,Tee] _ 10[WWI{MAWR SHAN NOT BE INSTALLED OR ARCIA°"'PV Alp AAA SINTEM WI WOWS MAMAS MOINIINICH II IOW WORM II I MONCDOPIORCONDIMICAS mem.coevre O▪PPOSITE ®�p BE NEC PM• .,. ' 'Ix .lot,.II IAN WAR SYSTEM LOAD DEMERS TO I 1"°"(AA OR NADA BAER NW MAW TOM MODULE WPM A NEC 705.12(0) WWII MEI GNOMIC M SITIINC BD 72M IS 7S1 IMRE ION WIRE SIZE IS SAUD UM MS TOTAL PP TRa..,,..om. ,xTR x .�xa ..._.._. ..x.�..,.r... �.o..x RPM No. Sheet RN EWM DEWING' NIA w .r WOAD WIRIER . .n„m,,„„x.,E AL n i ty1E .. EME . ,. _ EXARxx. . .A ....m....r. . e SOLAR vMassachusetts Department of Public Safety Board of Building Regulations and Standards License' CS-104144 Construction Supervisor REJIGGREENE tl I 43 FIRGLADE AVE SPRINGFIELD MA 01101 N1-A-A Expiration' Commissioner o3i11/8018 Office of Consumer Affairs Id Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170355 Type: Supplement Card TRINITY HEATING & AIR, INC. Expiration: 10/12/2017 PHIL SMITH ---- - 20 PATTERSON BROOK ROAD UNIT 10 - - - - -WEST WAREHAM, MA 02576 Update Address and return card.Mark reason for change. _.. . ,. ri Address r Renewal L Employment Lost Card "rimes of Consumer Agin&Resigns Repletion License or registration valid for iadividul use only Y'pMOME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: 'Art-Registration: Office of Consumer Affairs and Business Regulation 170355 Type: 10 Park Plass-Suite 5170 Expiration: 10/12/2017 Supplement Cord Boston,MA 02116 TRINITY HEATING&AIR,INC. TRINITY SOLAR PHIL RH 20 PATTERSON BROOK ROAD —_ _`� I P net WAREW1M,MA 02576 Undersecretary of valid without signature ACERTIFICATE OF LIABILITY INSURANCE 10/31/20 16 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terns and conditions of the policy,certain policies may require an endorsement. A statement on thS certificate does not confer rights to the certificate holder in lieu of such endorsements). PRODUCER CONTACT NAME: Arthur J. Gallagher Risk Management Services, Inc. 'W No Fitt 856-482-9900 FAX 856482-1888__ 4000 t Lauretic Drive Suite 200 _ ISM Rob-. Mount Laurel NJ 08054 ADDRESS INSURER(S)AFFORDING COVERAGE NAICF INSURER A:H DI-Global Insurance Company 41343 INSURED TRINHEA-03 INSURER e:Liberty Insurance Underwriters Inc 19917 TRINITY HEATING&AIR, INC. DBA TRINITY SOLAR INSURER C: 2211 Allenwood Road _- -- _ - -_- - -'-� — Wall NJ07719 INSURER o___,.. INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:2088149375 REVISION NUMBER: This IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHONM MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRI TYPE OF INSURANCE ADDL SUER' POLICY EFF POLICY EXP LIMRs LTRHMO MD POLICY NUMBER IMMMT NYYYI IMMD/YYYYI • A A I COMMERCIAL GENERAL LIABILITY EGGCC000065616 11/1/2016 11/1/2017 EACH OCCURRENCE 32,000000 DAMAGE TO RENTED Lmm I J C1 1MS.MAOE X OCCUR PREMISES(Ea em) I$100,000 I. _I MED EXP(My one person) 13 PERSONAL 5ADV INJURY 132I ,000.000 �GEN'L AGGREGATE LIMIT APPLIES PER. I GENERAL AGGREGATE '$2000,000 r—' nyPRO- POLICY, X-JECT it- ILOC PRODUCTS.COMP/OPAGG $2,000,000 OTHER. I 3 A 'AUTOMOBILE LIAMIury 111/1/2016 11/1/2017 COMBINLUSINGLE LIMI I IE 1 ,EAGCC000065]16 (Ea lMre) 3,000,000 ANY AUTO BODILY INJURY(Per person) S eurooswTlEO .8y ULEO BODILY INJURY(Per accident)rs HIRED AUTOS 1 AUTO-0vMEO PROPERTY eaddenxngMAGE S ) B UMBRELLA LPB X OCCUR 1000123 836-0�15 11/t/2016 11/1/2017 II/I/2012 1 EALX OCCURRENCE ,53.000.000 I X EXCESS LIB__ I_ Ii CLAIMS-MADE AGGREGATE 33,000,000 I DED , 1 RETENTIONS i ,Limit X Of$3,000,000 321,000,000 A WORMERS COMPENSATION I EWGCCMM065616 '11/1/2016 11/1/2017 PER 0TH AND EMPLOYERS'LIABILITY Ir STATUTE I ER ANY PROPRIETOWPARTNERIEXECUTIVE Y/x N/F 'EL.EACH ACCIDENT _ 51.000,000 OFFICERMEMBER EXCLUDED? T (MYandatary In NH) r_EL_DICF'SE-EA EMPLOYEEI$1,000,000 _ desalt.under i ,DESCRIPTION PTION OF OPERATIONS Mw ] J EL DISEASE-POLICY LIMIT I$1,000,000 DESCRFnAH OF OPERATIONS I LOCATORS I VEHICLES (ACORD 101,Additional Rema Its Schedule,maybe attached IImore space Is required/ CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Evidence of Insurance THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUCt4TH.ORRSED,REPRESENTAHVE 1144)/42 @ 1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD ___" The Commonwealth of Massachusetts w'. el _ Department of Industrial Accidents t_ : I Congress Street,Suite 100 it1- t Boston,MA 02174-2017 www.massgov/dia ° Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name(Busress/OtganiwionMdividual): to Wit4 MEAT I tan B. Ate 7WC.D0...4 nom 4TY 50LA . Address: 2z1I Au.EUwooD ROAN City/State/Zip: wALL, Mad 3E.f5E1 07719 Phone#: 73z-7%o-3779 Are you in employer?Cheek the appropriate box: Typeof project(required): LEI l an a employer with 1203 employees(full and/or Part-urea° 7. 0 New construction 2.0 I am a sole proprietor or pun ership and have no employees working for me in S. o Remodeling any capacity.[No workers'camp instance required.) 9. ❑Demolition 3.0i am a homeowner doing W work myself(No workers'cors.insurance mluired)s 4.0 I am a homeowner contractorsd will be hatingcontractorsI begonia all work on my property. will 10 Q Building addition ensure that all contractors either bass workers'cocpauaion twance or aro sole I I.®Electrical repairs or additions proprietors with nom,piyeca. 12.0 Plumbing repairs or additions 5❑I am a general contractor and I hate head the absocmaaars listed on the attached sheet. 11 These sr&sens o cactus have employees and hworkers'pomp.insurancinsurance.:uue.: 13.❑Roof repairs 6.0 We e a corporation and ks officers have exercised Sir right ofexenption per MGL c. 14.QOHser or 752,§1(4),and we have no employees.[No workers'corp.insurance required I °Any applicant that checks boyel nun also fill out the serum below showing their workers'compensation policy kdanerloi. t He meowms who submit this of avit indicating they are doing all work and then hire outside caaractas most submit a new affidavit indicating such. ttones:tors that check this box amen attached all additional sheet showing the name of the sub-connectors and stat whether Or not due unties haws employee.. If Om subwom otos hew employees,theymust Fronde their workers'comp.policy mm,hn. 1 atm an employer that is providing worker'compensation insurance for my employees. Below is the policy and job site information Insurance Company Name:HDIGlabal Insurance Company Policy it or Self-ins.Lic.#:ETriG0000006516 Expiation Date; 11/12017 Job Site Address: 4 DYEM SOPA,E waY, Su srE 4 l0 City/State/Zip:HDLYoKe, MA 61O4O Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the v'•lator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verifi ion. 1 do herebyrt pains] d, y;,a that the informs lionprovided above is true and correct. Si.tat.e. �./.I IJ Date: 1t-64-20 Ib phone it ! . - 'n -877•• Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: SERIES 100 UL ROOF VOU \ T SYSTEV The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical • innovations have been proven to drive - down costs and improve installation quality on more than 350 MW of solar installations. Pitched Roof Arrays Simplified -----•- '-: '- " .. The SnapNrack Series 100 UL Roof Mount System Ank is an efficnent, visually appealing,photovoltaic(PV) r,y '- module installation system.Series 100 UL is Listed to the UL Standard 2703 for Bonding,meaning that all system components have been Certified by UL for Roof System In 4 Simple Steps: electrical continuity,eliminating the need for additional p 6o to the online Series IDO Configuration grounding hardware- The System's components provide Tool(coni guresnapnrack corn)and select an adequate bonding path which has eliminated the 'Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 2) identify Site Conditions(Array Tilt, Building Listing ensures that SnapNrack partners can provide Height.Roof Type,Wind and Snow Loads) the best in class installations in quality,safety,and 3)Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials • All bonding hardware is fully integrated into the components 4)Place order with your distributor Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel,no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules LISTED PV Mounting System Patent Pending 2703 IIIIMIIIMIIIIIIMIIIIMMIIMIMIIM Start Boll warp StainWee Steel ,naprck Bondrng snaWgMSpit-loch WaheBolt with Split- plice 1pfiert Loci Wpsner Enoplerack Bondrng ntl taWn End SNplkacxSeabeCamer lc, Bnst roasernmog u Y' npfiaac Bontliny Wadplir Lock Bonding/_ 5 dlu W din NuCInM1p Bo[tom �Bontl09 s Hardware with Bdl with Channel Nut Split-Lock a{M1ers °vplilLock ` Metastable Ck Sending ampMid goading �,_ SnapHtaek Boni Washer A!}YNbIP EnG Clamp MW Gamy Standeed Pa Spike J wannest —r f MM tuptp.6AN4 caooar Wire owe.— SnapNraCk ground Lug —r• Assembly (ONE REQUIRED PER ROWOP MODULES) SnapNraere Bonding Vaasa! End Clamp(OCC)Wave �.r VEC Pull Slran GU._w flan Flat Washer SnapHrack landing arm Universal End Clamp Snaperrack Barmy �((J�j 7 ' - Sttared',"F Cram() aszemGY as SnaPulabOY.-' Senated StarnkreeO Congo,.SnaoNraN `SNPN FBOnding waB, steel Flange NO Sonoma O+annw Hat Rain CNlar, Channel ill Serratd Slainle55 a geNutSteel Flange Solt SMPIirMktaiMes141$ reetrerr;wren I Foot eorr StandoffnapNracs snpNrackll Forgoer.Mul Flmsu Foot Base Neave gown) Base Shown) SMlWaek—`�J,�.h% LIsM Meier Root In Base L pNsngg erase Assembly L Foot Base Sa � k apNrack loading -- . Smetan gentling --` EReeMetal �. Standoff Aaumbly l Feet Baca with Flashing Reof Bagse Feel gentling t Feet SnapNrack Series 100 UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Hashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs.&Certifications • listed to UL Standard 2703 or Grounding/Bonding and Fire Classification • Class A Fire Rating Type land Type 2 Modules •Stamped Structural Engineering Reports for all 50 States Grounding • SnapNraek Grounding Lug(One Lug per individual row of modules) Warranty • 10 Year material and worksmanship(download full details at snapnrack.com) Snap rock (877) 732-2860 www.snapNrack.com 0 n r o,, oapresp so.tN>M o +i- rr 2015ySna0", acePvMn i.nre Sy stem el ern reserved NOIR: aww -W16"[AG BOLTS MUST EMBED 2.7 INTO MDF SIWIC U N.MEMS RSTRAFiERS STB 2:MACE L FOOT -TORQUE 5111PMnAIX ALL TR 16"HARDWARE TO ON TOP OF ASHING COMPOSHTW ON L T -SILVER S.S.10-16 FT-U5 MDTIGNIEN NUT CAN BE MOUNTED4T*11ON -HAAS CM MOUNT EITHER STEP 2:SUP ANT OMENTATIDN fI SS.FLANGE NUT OFL ( � L FOOT BASE MID UNDER ROW AAUIOR135' arMASIOPE) OF SHMGLB ABOVE SNNWRACK OMMIEL NUT SS.BDLTAND .. ) SKIT WASHER i • E --- i A S.S.IAO SCREW E 7.f W1111 RAT WISHER SEMIPRO( < / 2.S MINLMLMEMBEDMBR STARDOM MIL '>�' /% IS STANpUD SWNRAOCOMPOSITION SIB 1: OLT T ROOF RASHING BASE TO ROOF WITN/ AG BOLT SNAPNRACICL FOOT BASE. - ' ROOF DEOmIG TYP. / i. �i" / MOF DEMING 1VP. AMMO)L FOOT MOMTOID POINT TOR / USE ON 0314POS1f81N MDF SURFACE Mm LOW TO MODERATE TILT RADS CM BE LEVELED UP TO 7ISING % IR TO TSO LEVELING SPACERS AS SHOWN IN"SIMS 1DD RAIL LEVELING COMPLEIW INSTALLATION RAFTER TTP. ARE E.d[ ccoac 'Meet G_-. Y� S ♦ \�tr,,�P�. PCNA: pm PW100NPEn: arlu*roN nn (1�1 J��( M pwlet Pq^ SiPO PEN dm PEN OETNL DI.HTEREDL FOOT TO EV bEEwA - - -.-. NYRpYTN n. O1''E'� 120113 METER F IX SNAPNRACK -2X SNAPNRACK LEVELING REVISION F USE CARE DURING LEVELING SPACER ' r-- SPACER - _ INSTALLATION TO ENSURE L - - THAT THE SET SCREW IS - 1X 756"-18 X 1"LONG -2X A"-18 X I"LONG - - THE TWO PIECES BEIUGHLY CENTERED NG JOINED EN II- SET SCREW 1 1 SET SCREW _ I I � f - I STANDARD SERIES 100 till I 'F■�' A ATTACHMENTS FEATURE 3"OF 3I '■ _ VERTICAL ADJUSTABIUTY ON ALL MOUNTING POINTS WITH L� lc 74. , THE USE OF 1"LEVELING 10.5 SPACERS __-. 9.5 8.5 TME INCH OF L5 ADJUSTBILTTY IS ACCOMPLISHED WITH SLIDING DETAIL A FEATURESFIRSTABUILT INTO BOTH L FOOT AND STANDOFF CLAMP SCALE S:8 COMPONENTS RAIL HEIGHT=2.5" RAIL HEIGHT=8.5' RAIL HEIGHT-9.5" RAIL HEIGHT=10.5" FOR AN ADDITIONAL INCH OF ABOVE ROOF SURFACE ABOVE ROOF SURFACE ABOVE ROOF SURFACE ABOVE ROOF SURFACE HEIGHT ADJUSTMENT,ADD 7 STANDOFF 17"STANDOFF T'STANDOFF 2'STANDOFF ONE LEVELING SPACER. USE PS TWO SPACERS OF SINGLE LEVELING SPACER ON TOP OF STANDOFF ON TOP OF STANDOFF NOT ATTACHMENT POINTSTS OF L-FEET OR 10' ON L-FEET 10"STANDOFFS. _ v.5 FOR A SECOND ADDMONAL 1 INCH OF HEIGHT _,I' fi.4 TWO LEVELINADJUSTMENT, D ANOTHER LEVELING G SPACERS R. USE NOT T TO EXCEED 10°k OF i 34 9lEr 14 �� 5I9 ATTACHMENT POINTS ON I II` I` L-FEET OR 30"STANDOFFS. RAIL =Liai HEIGHT ROF SURF ABIL ROOF SURF RAIL HEIGHT S5.4"RF ABHEIGHT SURF ABOVENELROOF SURFACE ABOVEELROOF SURFACE ABOVEELROOFTSURFACE ABOVEELROOF SURFACE ONE L FOOT ONE L FOOT ONE L FOOT ONE L FOOT PLUS ONE SPACER PLUS TWO SPACERS " UNDER L FOOT UNDER L FOOT I� MAINSTREAMfD ENERGY CORP DESIGNER GMym eiSCALE I l� DNS PART NUMBER IDESCRIPTION REV 2JII plyl�lll V IIS-U\SIN .... DRAETEP o"°'" 5100 D06 SERIES 100 RAIL LEVELING F � APPROVED 8Y DATE 120113 SNAPNRACK SERIES 100 ON FLASHED L-FEET REms10N FLASHED L-FEET ARE OPTIMIZED FOR QUICK - AND ROBUST INSTALLATION ON STANDARD - - COMPOSITION SHINGLE ROOF SURFACES -— FOR OTHER ROOF TYPES STANDOFFS ARE RECOMMENDED -SNAPNRACK MODULE ATTACHMENT HARDWARE I rSNAPNRACK _____ _ STANDARD RAIL ." 1 - — a —I _T_ 7 �r_ T ROOF RAFTER TYP(ROOF ATTACHMENTS SHOULD . -- �` - ��- ALWAYS BE EMBEDDED INTO ROOF RAFTERS OR STRUCTURAL MEMBERS SUCH AS STEEL PURLINS) ROOF SHEATHING, UNDERLAYMEM,-L AND ROOFING MATERIAL TYP. SNAPNRACK FLASHED 1-FOOT=/' MAINSTREAM ENERGY CORP DESIGNER �JO�C`d�IQlll VPC OJ GR/SiER OFIY FKas SCALE DNS PART NUMBER DESCRIPTION - REV roum aaay.r�wm SERIES 100 OVERVIEW ON FLASHED F ool LFEET DATE 120113AP APPROVED/3Y cia solar • • • f cc SolarEdge Single Phase Inverters pC For North America UJ SE3000A-US/ SE3800A-US I SE5600A-US/ SE6000A-US SE16OOA-US/SE1O000A-US/SE114O0A-US 2 a M t r • The best choke for SolarEdge enabled systems • Integrated arc faun protection(type 1)for NEC 2011690/1 compaante Superior efficiency{98%} ▪ Small,lightweight and easy to install on provided bracket • $uiitin modnle-Ievel monitoring e i Internet connection through Ethernet or Wireless si Outdoor and indoor installation • Fixed uoitage inverter,DC/AC conversion only ei Pre assembled Safety Switch far faster installation Optional-revenue grade data,ANSI C12.1 1AMn(Jti AlY EHaNfE JAPAN -1-Mt. AJC1RALIA-THE NE1HER LAND, WWW,s&aredge.us Solar - I I - Single Phase Inverters for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE70000A-US/SE11400A-US SE3000A-U5 5E3800A US 5E5000A US SE6000A-US SE7600A-US SE10000A US SE11400A-US OUTPUT .. N cnmrar AC Fower 0.4w, 300: 3800 S.A10 6000 7600 9989@205V 11100 I VA 103)0 @240v Max AC Powe!output 33X 4150 5409@dUBV tilt 8350 10800@208V 8000 V/. 545C€24ov Ig3sO p24Jv i_. I 414 C 4pat vonage NI n Non r:°.'- 18 278 224 i J l 3 C 0. Vet VOItageFn No i Marr . i . . .il J .... J / J. / J 1 24C-264Vat I C equeKr . n Nom War n93 €1 6051 tl coon,rvc tnng`7 60 5051 Yx M 1.,208V 4810208V MaxmousOutput Current 125 1 16 25 32q2 u12anV c7< A 21 C 2406 C OF01 Tmessnlc onn.y NI44tonng,...landing Prou-ction CountryConfigurable iM1rebholtls Ves Yxa _ INPUT W win Pow rpoul 4050 I51W 6750 8100 10250 13500 L'350 V! r 1rasmrmer4 .ess.ungrounded Yes.. Max .Pu'.Vonag.. 500 vaa Nom UC Inout Voltage 325 @ 208V/350 @ 240V Vdc 165.,a 2080 33@208v p Current 95 13 18 23 345 Ads ]s s C'z40V 1..30.5@240V L.. . Mos Input snort Circuit Current 45 FOc Reverse-Pnlenq Pratecton vee -. 1 oF3und caUlt yo anon un mverte�EMc er[Ycon 6� ty 977 .... 982 9ti3 9R 3nsiM1n \1 98 1 98 Y° ECWegned EXluenty 975 98 I °]Sfry]OBV 975 975 97@2086 975 ... _..... 980.240V 975@.24CV Nip t re Power CO umpLoo <25 _ - _. _- << N . . ADDITIONAL FEATURES�- - - - -- -- --- — _ -'Supported Comrnumcotion 4fiertaces 85u85.RS232 Mhernet 21gB e10poonall Revenue Grape Data.ANSI C12 1 _. . . .• opbonarr - _. I . . .... Rapid St umnwn-NEC 2014690.12 1 unctIonality enabled when SolerEage rapid shutdown kit 3 Installed" STANDARD COMPLIANCE Safety C UL1741 0.161 EE15 998.C5A 272 Grief C nnetnon 5[andarm IEEEl5g7 Emissions FCC parte class a INSTALLATION SPECIFICATIONS AC Output conduits /AWG range 3/4 minimum/1b 6AWG 3/ Min um/88AWG - DC pt rondult size,p of strings% 3/C rr rnr/]CsbinRs/166AWG 3/4 m/L2 strings/ ANG range _ 14-6 AWG Dimens ons with 5atety'w W. 3b.125s72/275 xV_x!84 30=i 125 e I0.5/ ia. plmv/w) 7750315.260 mm VieigM1i with Safety 5wM1[6 51.2/212 5A]/24] 8E4/40.1 Ib/kg Naturat [ Natural Convect-1.7r, and interna! Fad fuser reLlateabre3 an lu3 - I rePlaceabe) I Morse c25 050 (IBA Min Max0 erabngTemperature RanB$. . -13tCs140;-25C+50I401e r60 versionavailable'9 Protecnen Rating NEMA 3N r' EM .-= - RoHS cc solar - • • ust SolarEdge Power Optimizer Module Add-On (-- 2300 P350 i P404 P405 l P500 C— cc w Q / ,i PV power optimization at the module-level • Uo tc i5#more energy • Sup.ce efic ertty{99 5%1 ▪ Amngate5 a9 types of rnndules mismatch-loss from manu'acvmng to crane to parta7 shad r) • Ficvlbrr uyxte trtles er for maximum space un Manon fast r talloror wnh a sngie boR Nt ger rt in naictc,ante rvah module levei monitorng ▪ iMeo:dw-tsvel phage sautdewtt for m4la1ler ane firenehter sJ;ery solar " • • a SolarEdge Power Optimizer Module Add-On P300 ( P350i Pana P405 P500 P300 P350 P500 P404 P405 [fur 60Eel (for h,gh-power (for 96-cell Ifor60-cell do it hi n firm modu les( 60-cell and for modules) and 72 cell, nodule() 72 cell modules) short strings) INPLIT ICi. . �.. 1S .1. h— .I ✓.. c n , • _ c OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREOGE INVERTER) OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREOGE INVERTER OFF1 STANDARD COMPLIANCE R INSTALLAl ON SPEC FICATIONS nom . _:1_ Inn .Lvi LIC➢ .e,'.f VALr PV SYS M LESION USING A SOLAR(UGF ININVERTER SINGLE PHASE THREE PHASE I 3 .. PAGE 51 LEAVES POWER DISTRIBUTION CU9AL BUG•BITES" SP I. 9DC Insulation Piercing Connectors LIMO ' Eliminate S need for conductor lnsublan elnppinp No taping reouired eller melell611on Fol copper to capper.copper 30 aluminum,or aluminum to aluminum eppeceSfon5 .. For uge on Nsulaled conductor only IPC SERIES _ i' NAPO CATMOG _YORE/WIGS TOPOUE I C411 ' EST.6N PING _ NUIROER NM1SN NA64 TAPVOL/5 1E RLBS ON wflEMlAr) UNIT 11110 IPC 1002 Iru 8 2.6 300 1 16 1 f 2.67 'ern 13107 IPC40M 00.4 6 A OM 11 1130 ON 19108 91/C46202 O-0 000 5 I 406 CMA y 13109 NY C30 N . -6 MO 30 4.17 CRN 13113 )0Cady 350.445 N 10 300 25 IIS cin 13114 1PC 3455 350 410 350-4.0 YG 25 i 09 CM 13115 41PC 301 603•130 10.12 300 25 2.05 CPI 13104 'IOC 3025 501.150 250-4 WO 55 4A CRN 13105 "IPC 5050 500.302 5w-150 WO 75 2.64 EA. CAUTION 13106 'IPC 7501 7W-500 5m.308 500 75 2R 61 USO BLs'BIIes on 350 Volts.Wets 3m Pao 11224M391ounds0•e114me) __.. — _- insulated cable only) t Na tea craw Do 2301 easel on GSM c &b 1 Dual-Rated �l SP GUTTER TAP CONNECTORS CU9AL High strength aluminum aloy6061-T6,11nplated LISTED BOOV 90 C Ley-In designed main conductor noting continuous Tap persist or perpendicular to main Q GP SERIES ;, NO/00 CATALOG COMWCTOtMNuE AMM03.OAIPNsCx60x1 CRN ER&OPPOG 1///// N41001R NIMekT WIN W N -- L OTT *EIONTOMI MIT / / 1311? OPV 2.12 4.12 SIX PG 11 119.. 1 143 RN / 13111 OP/0 W-2 1ra-/2 SOL I 3'4 IV. 1 1.19 CTN `� I{I/�1.� 13119 MIO 250.119 250-6 I'L. 1I. 3'h 1 254 LIN � ..I 13121 OP350 353.00 3506 1'f.. 1'l. 2'i.. 2r6 CIN 555 For13122 OP 3 505-350 510.2 0. . 3.10 CM!08i par-to-aluminum. 11123 OP 350.500 500.2 2 1r. 3v. xs CTu CDPDer-lo-dllmlinum, - - aluminum-to-aluminum /GPIMPbMi wen. O.de-IMMor M neon mended b 4110IP1=sten p'PPeoen 6000 ROT Snap-on insulating covers for use wllh GP connectors For Indoor use only GPC SERIES xAB CAT/CC FORCONNECTOR ' 1 eMROZ CMB15WN4 Nxl 1 OTT I eIG SNIP1/0/1 U, x13137 04Cesn CO 0P2eroe COLOR 1__.19 W L I Iz wEIONTIea GIN :•••1 livi GPC 2' c YELLOW 4a cru .,t.1`„ 13131 Gee 0 1 RA I , Ia CTN •,.� p)••�� v140 OPC230 c - . 5o 340 CTN 13141 ore 35 m� z cin �l���r V:---1„..,/- 13142 OPC500 02530 0 2 0+6 RN 13131 OPC TO cn rs0 ICN,,,„ _- - • un: CM ' In.lli ' w 0tea ves-use Corn 11 Nn.1e0e Pa/k.Clnlon CTtw05413•PMn0 R50-664.4505'Fax 060.6e4 4506 TOLL FREE 1-60010.1130(Oubde CT) ® Le With LG, Ufescond it's all possible. C— MOnOX f • • , , 4 4r ,_ i . . . 60 ref! fr . . . . . ) . • l l ' ' ' • . a. 4 4 /._/D':� v , LIGHT AND ROBUST PQ CONVENIENT INSTALLATION 100%EL TEST COMPLETED Ry THE EXTRA 2X POWER - I RELIABLE WARRANTIES POSITIVE POWER TOLERANCE MonoX ® LG270S1 C-A3 41ECHANICAL PROPERTIES FI EC IRI(AI PROPERTIES I STO} EI ECTRICAI PROPERTIES I NOC]'1 CERTINCAFIONS AND WARRANIV _... .T TEMPERATURE CFIEFFICIENTS pIMEN51pN51MMllNI CHARACTERISTIC CURVES ° WIsIG.rtsall pnsSiMt rfec Gond O