Loading...
06-055 (19) • inAPo6 - oCS SAGE ENGINEERING AND CONTRACTING, INC. DESIGN-BUILD DEVELOPMENT, ARCHITECTURAL ENGINEERING, AND CONSTRUCTION MANAGEMENT March 28, 2017 Louis Hasbrouck, Building Commissioner City of Northampton 2 12 Main Street Northampton, Ma 010W RE: Linda Manor Extended Care Facility Porch Renovations, 349 Haydenville Road, Northampton, Ma SAGE Project No. 0558 City of Northampton Building Permit No: BP-2017-0353 Dear Mr. Hasbrouck: On behalf of Linda Manor Extended Care and Berkshire Health Care Systems., please find the enclosed Final Construction Control Field Inspection Report dated March 28, 201 7 as required by The 2009 International Building Code and the Massachusetts State Amendment to the 2009 International Building Code for your reference on the existing project in progress named above. Also included is the final construction control affidavit. We are available at your convenience to review the inspection reports or answer any questions or concerns you may encounter regarding this project. Sincerely, / `ryan B Baha; P.E. Project Engineer SAGE ENGINEERING 4 CONTRACTING, INC. 199 SERVISTAR INDUSTRIAL WAY-SUITE 2 WESTFIELD, MASSACHUSETTS 01085 TEL: 413-562-4884 m FAX: 413-562-4899 PAGE 1 OF I www.sayeLlc.com • CONSTRUCTION CONTROL FIELD INSPECTION REPORT Project: Linda Manor Extended Care Porch Ren SAGE ENGINEERING&CONTRACTING, INC. Job Location: 349 Haydenville Road 199 SERVISTAR INDUSTRIAL WAY, SUITE 2 Northampton, MA 010603 WESTFIELD,MASSACHUSETTS 0108$ Inspection Date: 3-28-2017 (413)562-4884 Time: 8:30 AM Sage Job Number. 0558 Building Permit No: BP-2017-0353 WEATHER: Clear,26° EST.%OF COMPLETION: 90% CONSTRUCTION SUPERVISOR: Frank DeMarinis,Sage Engineering&Contracting, Inc. PRESENT AT SITE -Sage Engineering&Contracting,Inc. Equipment: None WORK IN PROGRESS - None WORK COMPLETED SINCE PREVIOUS INSPECTION - Exterior wails have been framed,insulated,and sided. - Interior walls have been sheet rocked and painted - Windows have been installed - Blown in insulation installed both in ceiling and under concrete deck - Electrical has been installed and inspected - PTAC unit has been installed - Bay window was removed and opening cut in wall and trimmed out. - Existing porch door has been removed and trimmed out, - VCT flooring and trim has been installed. OBSERVATIONS Work in Progress Is In Compliance With Plans&Specifications. INFORMATION OR ACTION REQUIRED COMMENTS The renovation work on the porch has been completed in substantial conformance with the approved plans and the space Is safe for Occupancy. / ��L- INSPECTION BY: .4> ov.of 4.485 ENGINE -ryen Balickl,P.E. r^�V + � DATE: 3-26-17 c f '+� 1 DATE: 3- `o chip 4 'S 4 ST H 4,"v "it's ' SrnNAL EPS'A City of Northampton ;.. s — , Massachusetts S $` � d c ' f; 61`f` DEPARTMENT OF BUILDING INSPECTIONS o tt y r:� 212 Main Street • Municipal Building JjNti/ 6C �- Northampton, MA 01060 INSPECTOR Louis Hasbrouck Fax: 413-587-1272 Chuck Miller Building Commissioner Phone: 413-587-1240 Assistant Commissioner FINAL CONSTRUCTION CONTROL DOCUMENT (For professional Engineers/Architects responsible for Entire Project) Project Title:Linda Manor Porch Renovation Date: 8-10-16 349 Haydenvi11e Road 6 55 SR Project Location: Map: Parcel: Zone: Scope of Project: Enclose existing 3 season porch for year round use. In accordance with the Eighth edition Massachusetts State Building Code, 780 CMR Section 107.6: Frank DeMarinis Mass. Registration # 41640 Being a registered professional Engineer/Architect hereby CERTIFIES that I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: [ ] ENTIRE PROJECT For the above named project and that to the best of my knowledge, such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, all acceptable engineering practices and all applicable Laws for the proposed project. Furthermore, I understand and AGREE that I shall perform the necessary professional services to determine that the above mentioned portions of the work proceed in accordance with the documents approved for the building permit and shall be responsible for the following as specified in Section 10.7.6.2.2: 1. Review of shop drawings, samples and other submittals of the contractor as required by the construction documents as submitted for the building permit, and approval for the conformance to the design concept. 2. Review and approval of the quality control procedures for all code-required controlled materials. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine, in general, if the work is being performed In a matter consistent with the construction documents. I shall submit periodically, in a form acceptable to the building official, a progress report together with pertinent comments. Upon completion of the work, I shall submit to the building official a final report as to the satisfactory completion and readiness of the project for occupancy. � - • evAl1OFM4s n Signatu - . • S- - e' red Professional ° FRANK DFLIAIRIJi �R CIVIL No.41640 /� �1S Day of elAPCH 20 C) b< oisrevE° �2 '6 0%AL E°<� The work covered by this permit has been completed in substantial conformance with the approved plans and the space is safe for occupancy.