Loading...
32A-138 (50) FROM : Steve Alves PHONE NO. : 508 238 0021 P02 David C. Maeartney Code Consulting Service, 45 Howard Street South Eaton, MA 02375 Telephone: (508)-238-9471 MEMORANDUM TO: Mr. Roy Brown, Architects, Inc PROM: David C. Macartney, Code Consulting Services 00N4-- DATE: ( January 12, 1993 SUBJECT: Exit Calculations far . During my June 2, 1992 site visit to Fitzwilly's Restaurant, I measured the exit doors from the restaurant for purposes of determining the exit capacity. The following measurements and figures were obtained: Main front exit door - 311 inches clear @ 0,2 inches per person — 150 persons Left front exit door - 39' inches clear @ 0.2 inches per person — 190 persons Left rear exit door - 321/4 inches clear @ 0.2 inches per person — 160 persons Right rear exit doorway - 54 inches clear @ 0.2 inches per person ee 270 persons There is a fifth door in the kitchen which could be utilized a an exit door,but due to its size and condition, 1 did not include it in my computations. My conclusion was that one of the rear exits could be eliminated, If necessary,while still satisfying Massachusetts State Building Code requirements fur number of exits, capacity of exits and remote location of exits. It was my opinion that the left rear exit could be eliminated with the least impact upon traffic flow and exit access, as the main floor aisle and mezzanine provided separate paths into or out of this area of the restaurant. I trust that this information will be helpful to you in your work with the ownership of Fitzwilly's.