Loading...
18C-180 70 HATFIELD ST SM-2017-0025 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON IGIS# -712178 "`" ,, Map 118C 4 a. Block: i`8°- ---„ ' ' e SHEETMETAL PERMIT Lot: a. permit: SHEETMETAL Category: HEETMETTAL 'Pormit# SM-2017-0025 I PERMISSION IS HEREBY GRANTED TO: Project# {JS-2 0 1 7-000622 �Si0oo0.00 — —!Contractor: License: Expires: FEst.cost:eCharged:$25.00 ':ROCK VALLEY HVAC Sheetmetal-2626 04/28/2016 ;Balance Sue:1'800 !Owner: L P AUDETTE BUILDERS INC of Fixtures: !Applicant: ROCK VALLEY HVAC DigSafe#— —..-IAT: 70 HATFIELD ST lUseGroup I CLonstClass ISSUED ON: AMENDED ON: 02-Nov-2016 EXPIRES ON: TO PERFORM THE FOLLOWING WORK: UNIT B-COMPLETE HVAC SYSTEM,ALL DUCTS SEALED&INSULATED TO ENERGY STAR STANDARDS THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt Nec Date Paid: Check No: Amount Sheetmetal HEC-2017.001785 01-Nov-16 1245 $25.00 212 Main Street,Phone:(413)587-1240.Fax:013)587-1272,Email:lhasbrouckidnarthamptonma.gov GeoTMS®2016 Des Lauriers Municipal Solutions,Inc. File#SM-2017-0025 APPLICANT/CONTACT PERSON ROCK VALLEY HVAC ADDRESS/PHONE 7 APPLEWOOD LN (413)535-7804 PROPERTY LOCATION 70 HATFIELD ST MAP 18C PARCEL I80 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid }t apt�I vis- Building Permit Filled out `F[ VN Fee Paid TvpeofConstruction: UNIT B-COMPLETE HVAC SYSTEM,ALL DUCTS SEALED&INSULATED TO ENERGY STAR STANDARDS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 2626 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER : § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee P it Street Co. iss.. Permit DPW Storm Water Management � Si f uil rh coral ate Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning&Development for more information. Commonwealth of Massachusetts � Nou - Sheet Metal Permit a e: 10/24/2016 Permit# 51,1 '17-25' Estimated Job Cost: $ 10,000 Permit Fee: $ Plans Submitted: YES J NO Plans Reviewed: YES NO Business License# Applicant License # SM2626 Business Information: Property Owner/Job Location Information: Name: Rock Valley HVAC Name: L.P.Audette Builders Inc. Street: P.O.Box 1162 Street: 70 Hatfield Street Unit B City/Town: Easthampton, Ma City/Town: Northampton Telephone: 413-535-7804 Telephone: 413-539-7381 Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses J Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. J over 10,000 sq. ft. Number of Stories: 2 Sheet metal work to be completed: New Work: Renovation: HVAC "I Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/ Vents Air Balancing Provide detailed description of work to be done: Complete HVAC system, all ducts sealed and insulated to energy star standards INSURANCECOVERAGE: J I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yeslip No❑ If you have checked Yes,indicate the type of coverage by checking the appropriate box below: A liability insurance policy it Other type of indemnity ❑ Bond ❑ OWNERS INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check, One Only r Owner Mr Agent ❑ Signature of Owner or Owner's Agent By checking this box❑,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be In compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation:YES NO,-,� Progress inspections Date Comments Final Inspection Date Comments `.. TypeJof License: By //Master Title ❑Master-Restricted �I ' City/Town ❑Joumeyperson Signature of Licensee Permit it ❑Joumeyperson-Restricted License Number: SM2626 Fee$ ❑ Check at www.mass.govtdpi Inspector Signature of Permit Approval N Basement ti /t, 4/a T.217.2'p"� 1-1-',61 7a,.S/ Room11 edws 7;f./s/ cbc ' a.. 14,-/.72-,e4/ tvaS elvS Z-1/5/ . . ... t Job#: Rk ValleyHVAC 1 : so Rock Performed&x: Page 1 Larryaxlege P.O. 6041162 Right 9uik®Unleree12017 74 Harrold Steettlna Easthampton, Me01027 17010RSU24598 Norhampbn,Ma 01060 Phone 413-53578)4 2016-OG-31125226 Phone 413-5394381 _eatbatl968 HaUekt SYeetrup auak1950(fama.com w#N.rcckValleyhvac.com Roa rraBeyhvaaCayahoo cam N �� Level 1 Kitchen Wash/Bath 11 Living Room 0 Entry_ Job#: Rock Valley HVAC S`�9. 1 . 50 Performed for: Page 2 Larry Oudele PO- Box 1162 Rg0t-Srile40Univeral2017 74 Hatfield SkeetUnOB Ea6fltamr 1, Ma 01027 1].0.10RSU24598 Norhan413-53901060 !Thane 413-5357804 201604-3112:5226 Phone413-539-]381 ..ealloaC568 Haeeld Seeetrup aucla1950®9med mm www Mdwalleyhvac.com RockvaYeyhvacayahco.cum N SS 07 of i' Level 2 a Bath Bed allEntry/ Stairs > Master M Bath emir r/ Perrormeci for: Rack Valley HVAC Scale Page 50 larryAucaaa P.O. Boz 1162 Right-SLdeeUniveri 12017 68 Ha16ekl areet Ea6lhanlptan, Ma 01027 17.010 RSU24598 Nprlhampbn,Ma 01060 2016-Oct-24162956 Phone:a-m-53943M Phone. 413-535-7804 _eatbadafia Ha6ekt Steatrup avmossootamaamm a wrockvaleyteaac.mn Reckvaayhva:©yaheacccm wrightsoft° Project Summary Date: Jul 25,2016 Entire House By: Rock Valley HVAC P.O.Box 1162.Easthampton,Ma 01027 Phone:4135354604 Email:Rockvalleyhvac@yaheo.com Webwww.rockval@yhvac.corn Project Information For: Larry Audette 70 Hatfield Street Unit B, Northampton, Ma 01060 Phone: 413-539-7381 494 %SRA v/5 Notes: Email: audla1950@gmail.com ` 1 c5 el Va gcr(O IJ 319 Furnace_ _ Rtk Af ,icko S(an YXLBW3 D53 Hca I•6 Tc'" AP cc- , ( - P r,acn SFx.ah a'`� t' A/L ari, - R li&Lf (Can 5Icnotate' gig 7A go/f1Llotx: R . lot5tt C. Desi. n Information Weather: Springfield, Westover AFB(Worchester Dd), MA, US Winter Design Conditions Summer Design Conditions Outside db 0 °F Outside db 87 °F Inside db 70 °F Inside db 72 °F Design TD 70 °F Design TD 15 °F Daily range M Relative humidity 50 Moisture difference 31 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32576 Btuh Structure 12005 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32576 Btuh Use manufacturer's data n Rate/swing multiplier 0.92 Infiltration Equipment sensible load 11045 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 1 (Average) Structure 758 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1224 1224 Equipment latent load 758 Btuh Volume(ft3) 10491 10491 Air changes/hour 0.50 0.21 Equipment total load 11802 Btuh Equiv.AVF (cfm) 88 37 Req. total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 647 cfm Actual air flow 647 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.94 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2016-0ct-2416.51.57 wrightsoft" Right-Sulo Universal 211717.0.10 RSU24596 Page 1 s\Wes\Desktoptueal iadai66 Hafkk Streel.mp Cak=MJ6 Fran Dow faces: N