Loading...
32c-050-001 . 1.06 „Le\ Sad -sem v Carlson&Schmitt Architects,Inc. July 16, 2002 Anthony Patillo, Building Commissioner City of Northampton 212 Main Street Northampton, MA 01060 Jilt 1 R ZVOZ Re: Bay State Hotel Dear Tony, Per your questions regarding provision for bathroom facilities, I've broken down each floor for occupancy and calculated conformance by water closet/urinal provision, the most restrictive criteria: First Floor: Required: Dining Areas (2) 1065 sf x 1 seat/15 sf= 71 people Bar Capacity (Including adjacent counter seating) 37 ft less 2 ft (drink pick-up) = 35 ft x 1 seat/2'-6" = 14 people Staff 5 people 90 people Provided: 1 toilet at Women's Room plus % toilet at Unisex Handicapped Bathroom x 30/fixture = 45 women 1 toilet and 1 urinal at Men's Room plus Y toilet at Unisex Handicapped Bathroom x 60/fixture = 90 men Second Floor: Required: Dining Areas (3) 1237 sf x 1 seat15 sf= 83 people Staff 5 people 88 people Provided: Same as First Floor 45 women 90 men r South End Hr;41 rd,, Agnwnm,Atassmtuunts 01001 (419}786-5556:e4phaoe (413)7864130f wwwsuston_a9vnibernn • Third Floor: Required: Lounge Areas (2) 687 sf x 1 46 people seat/15 ft = Bar Capacity 29'-6" less 2 ft drink pick-up = 27'-6" x 1 seat/2'-6" = 11 people Staff 3 people 60 people Provided: Women — 1 fixture x 30 people Men — 1 fixture x 60 people By these calculations we meet the requirements for plumbing fixture provision. They appear close but Dan Bishop tells me that in their experience, staffing and diners are somewhat male weighted. And, of course, the new facilities dramatically increase the number of fixtures and the handicapped accessibility at existing same-use areas. If you have any questions, please give me a call. Sincerely, Charles T. Schmitt 2 I'-OIYi 5'-I/4' 4% ! 1'-03'i Xi' 5'-04 y I'-• i E-1.1. 1Y. 1'-O'/i" 51' S'-p�' 11 .T ILII: H/C UNISEX • ®/ H/C UNISEX Iv£N / O:.'�� 6 '^ 113 _ O ':.� O m 113 114 / 7 0 r 114 (�) © � Ci� o 0 I: swam .o. L 7-1. 1 i[ 7-94' j 19�' S' • i% 3'-14 2 T,. 1 Y'-91i -r. 1 ry p. 1 1 WOMEN ° WOMEN - C1 A. III ......... 0 �� ��� 0 LPOL ;r. .. :.. :....::........ _...,.. . . .:. . ....: N- .:....../..:..: ..Ell .111 . . . . ......... . . .. .. . ...: :.. I 1ST FLOOR BATHROOM PLAN caF"_,.-.9z,- 2ND FLOOR BATHROOM PLAN SCALE: I/4" = 1'-0 7- /fp. ,`.\ SCALE: I/4" = 1.-0" '10 J1, \ � ' ,