Loading...
32C-052 (8) 1 PEARL ST SM-2017-0016 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON Eats#: 10114 Map: ,_- 32C (Block: 052 - ~ ttt r t 001 SHEETMETAL PERMIT ttt Permit SHEETMETAL NIP mz< 'CategorySHEETMETAL Permit# SM-2017-0016 ' PERMISSION IS HEREBY GRANTED TO: Project# 5-2017-00020.8 ',Est.Cost: $53,000.00 ;Contractor: License: Expires: Fee Charged: .50.00 -- --- ''ALL SEASONS HEATING AIR Sheetmetal- 129 Balance Due:$.00 Owner: GLEASON HELEN C&PATRICK T TRUSTEES OF HELDON REALTY #of Fixtures Applicant ALL SEASONS HEATING AIR DigSafe# _AT: 1 PEARL ST UseGroup IConstClass ISSUED ON: 22-Sep-2016 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: INSTALLATION OF 3 HVAC SYSTEMS FOR OPEN FLOOR PLAN SPACE THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2017-001168 21-Sep-16 1728 $50.00 212 Main Street,Phane:(413)587-1240,Fax:(413)587-1272,Email:Ihasbrouck@northamptonma.gov GeoTMS®2016 Des Lauriers Municipal Solutions,Inc. File# SM-2017-0016 APPLICANT/CONTACT PERSON ALL SEASONS HEATING AIR ADDRESS/PHONE 93 ELM ST (413)247-9842 PROPERTY LOCATION 1 PEARL ST MAP 32C PARCEL 052 001 ZONE CB(1001/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED y OU Fee Paid ( ,L ( r/,1 X 4 co Building Permit Filled out Fee Paid Typeof Construction: INSTALLATION OF 3 HVAC SYSTEMS FOR OPEN FLOOR PLAN SPACE New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 129 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO TION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee F-- Is. El Street Commission Permit DPW Storm Water Management Signature of Building iciaOf7 l Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. Commonwealth of Massachusetts aI City Of Northampton �`I o Sheet Metal Permit N h a : G a l-aDi bPermit» cal 5-0 Car)ti 1 w s • ated Job Cost: $ t .. DOD Permit Fee: $ 50 CC s k. s Submitted: YES NO Plans Reviewed: YES__ NO Business License# !"{ Applicant License# 1AC-1. Business Information: Property Owner!Job Location Information: Name: j?ers.! v c Name: _Th2/satat As o Street: 9.3et—"Man- Street l Q42.4-'; Sus/— City/Town: ytn3�.ra� OIO3City/Town: k)ac't> 44..-Q4on,.r Telephone: t'113-dYl-9via., Telephone: 4k: j30-4ID° Photo ID. required/Copy of Photo I.D. attached: YES NO Stan Initial J-t nrestricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail X Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. X over 10,000 sq. ft. Number of Storks: Sheet metal work to be completed: New Work: X Renovation: HVAC.,X_ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: :.1 Ail rAln� aa a A J Itr - las Dre'- 9Ans.t.a GQ€*12 Fees with Building Permit:$25.00 Residential,$50.00 Commercial.Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential, $100.00 Commercial INSURANCE COVERAGE: I have a current gehnhy insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 yes❑ No❑ If you have checked as indicatethetype of coverage by checking the appropriate box below: A liability Insurance policy ,Pal Other type of indemnity ❑ Bond 1 OWNER'S INSURANCE WAIVER:I am aware that the licensee doer not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waivacthis requirement. Check One Only Owner ❑ Agent ❑ • Signature of Owner or Owners Agent By checking this boxG,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are True and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation:YESNO Frngrocc Lncpprtinny Date f omau^r+rc Final JncpertipM Date FnmrnpnR. Type of License: By ...... o Master {/ `- �//i ll / Title MesteerieSeieted City/Town ❑Journeyperson Si( re of censee Permit#_ X39 ❑Journeyperson-Restricted `-� Fee$ License Number - Check at www mann(rent( Inspector Signature of Permit Approval I , '� 11 I >dl1 am .4 y . ( _ • Z I I T • 4�l . - II � � �, Or gr II A wgtt\'" II SOO 4 II [� h1 At u �� Ii 4 ,1,1 I I fe ` LA II A .Trs.l f r v0...\. fj we j W?4i same �A�,yn r ..1IS ti° I ',Jnd ;al ( ,1107 . Jou ALL SEASONS Scalia: :145 Performed by DAVE LAYWRON fan Pay 1 MOR11WW1a1 RETMSPACE 33 SCHOOL STREET F6219-599999 U al 2015 HATFIELD,MA 140.19 1191217213 2016S1p071{35:12 ..LL sFASO4S Ablarytn Sma.." Load Short Form Job: Date: . Entire House an DAVE LAMPRON ALL SEASONS 33 SCHOOL STREET,HATFIELD,MA Project Information For NORTHAMPTON RETAIL SPACE Design Information Htg Clg Infiltration Outside db(F) 0 89 Method Simplified Inside db{ F) 72 73 Construction quality Semi-loose Design TD(M) 72 16 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(grab) 31 25 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Corgi AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 If Total cooling 0 Btuh Actual air flow 7149 cfm Actual air flow 7149 cfm Air flow factor 0.022 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft) (Btuh) (Btuh) (cfm) (cfm) Room2 5600 284611 124048 6123 6308 Bathrooms 350 47728 16540 1027 841 Entire House 5950 332339 140588 7149 7149 Other equip loads 0 0 Equip. Q 0.94 RSM 132152 Latent cooling 23669 TOTALS i 5950 I 332339 I 155821 7149 7149 enknfol c values have been,narwMy ov rMMea Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-022L20 00 1300 wrightsoft` pi9 ht-Su ISO Univ erszi 201515.0A 9 RSu 12110 Page neakIptLOMSAL:.SEASONS Northampton stars mp CUIc=MA. Front Door faces N z)t; ste" 2 $ Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH Upflow,Convertible to pn'e= Horizontal Right or Horizontal Left S9V2C100U4PSAA :`� Lr � Note:GranInes in this document are for representation only Actual model may dotter in appearance. TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of beating,ventilating,end air conditioning equipment can be hazardous and requires specific knowledge and training Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,a['serve all precautions In the literature and oethe tags,stickers,and labels tbatare attached Lathe equipment, February 2016 S9V2C100U4-SUB-1-EN �R�ingersdlRand 0 C .r S. rCD 1."t , a ' i f^ I Upflow Furnace -e � ...yit- 1 t C Size Cabinet CO Cn -L�, ,..,- I ' to _— n I Is _ , d I T i�, i. IS . . o _11 I i , L . . . L V o tr v a a z Product Specification MODEL S9V2C100U4PSAA MODEL S9V2CI0004PSAA TYPE Upflow/Horixontal Type-Fired 409 Stainless Steel RATINGS(a) -Unfired 29-4C Stainless Steel 1st Stage Input BTUH(ICS) 65,00(1 Gauge(Fired/ 20 1St Stage Capacity STUN 63,05(1 ORIFICES-Main 2nd Stage Input MN 100,000 Nat.Gas Qty.-Drill Size 5-45 2nd Stage Capacity B'1'UH(ICS)ml ai 97,000 LP Gas Qty.-Drill Size 5-56 1st Stage Temp.Rise(Min.-Max.) 1 25-55 GAS VALVE Redundant-Two Stage 2nd StageTemp.Rise(Min.-Max.) ;>-(5 PILOT SAFETY DEVICE _- AFUE(%) 96.0 Type 120 V SiNi Igniter BLOWER DRIVE DIRECT BURNERS-Type Multiport Insbot Diameter-Width(Id.) 11X10 Number 5 Na.Used 1 POWER CONN.-V/Pb/HZ in 120/I/60 Speeds(No.) Variable Ampacity tin Amps) 10.8 CFM vs.in,w.g. See Fan Performance Max.Overcurrent Protection(Amps) 15 able -- Motor HP 3/4 PIPE CONN.SIZE(in.) 1/2 RPM Variable DIMENSIONS H x W x 0 Volts/Ph/Hz 120/1/60 Uncrated(tn.) 34 x 21 x 28-3/4 FLA 8.0 Crated(In,) 35-1/2 x 23 x 30-7/8 _ COMBUSTION FAN-Type Centrifugal WEIGHT Drive-No.Speeds Direct-2 Sbipolttjp 01%4/Net(Lbs.) 154/144 Motor HP-RPM 3300/2600 "' For(LS.applications,above input ratings NOTIONare up to 2,000 feet,derete 4%per 1,001)feet for elevations above 2,000 feel'.above Volts/Pb/Hz 120/1/6tlatr level.For Canadian applications,above inpuatings(9Tu H)are FLAupto 4.500 feet,dente 4'N per 1,000 feet for elevations above 4,500 0.66 feet above sea level. f2L1ER-Funrishetlt NO ail Central Pomace heating design arecertied to ANSI 22149/CSA 2.3-latest editlon. Type recommended High Velocity (a Based on U.S.government standard tests. _ re Refer to the Vent Length'table in the installers Guide. Hi VS.(No-Size-ink.) 1-20x25-1 in. ^( All 59V2 furnace models have a vent outlet diameter that etit.lals 2 in. VENT PIPE DIAMETER-Min(in ) 10 The above wiring specifications are in accorpance with National re11r1 2 Round Electrical Code;however.installatios must comply with local codes. HEAT EXCHANGER S9V2C100U4-SUB-1-EN 3 Heating and Cooling Airflow Tables S9V2C10004PSAA Tablet. S9V2C10004PSAA Heating Airflow S9V2C10004PSAA Furnace Heating Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter 1st Stage Capacity=63,050 2nd Stage Capacity=97,000 Airflow Target External Static Pressure Heating Setting Airflow 0.1 0.3 0,5 0.7 0.9 CFM 1191 1199 1206 1216 1224 1.974 1146 Temp.Rise 50 49 49 49 49 Watts 1.33 192 251 310 369 CFM 1314 1304 1294 1284 1274 Medium Low 1280 Temp.Ree 45 45 45 46 46 Heating 1st Watts 173 235 299 359 421 Stage CFM 1478 1.466 1953 1441 1428 Medium lm 1446 i Temp.Rise 40 40 40 40 40 Watts 243 304 364 425 485 C„F1 1498 1511 1524 1537 1550 High 1493 Temp.Rise 39 39 39 39 38 Watts 264 330 397 464 531. (PM 1486 1988 1496 1503 1591 Low 1450 Temp.Rise 60 50 60 60 60 Watts 244 312 380 449 517 CFM 1658 1656 1654 1652 1550 Medium Low 1620 Temp,Rise 54 54 54 54 55 t Heating 2nd Watts 330 408 486 - 564 642 Stage CFM 1869 1857 1846 1811 1}14 Medium tat 1830 Temp.Rise 48 48 49 49 52 Watts 971. 549 628 677 695 CFM 1959 1919 1879 1811 1714 nigh 1690 Temp,Rise 46 47 48 49 52 Watts 540 600 660 677 695 rai Ferfary Setting. — 4 S9u2n00u4-Sue-/-ery Heating and Cooling Airflow Tables S9V2C10004PSAA/S9V2C100D4PSAA Table 2. S9V2C100U4PSAA/S9V2C100D4PSAA Cooling Airflow 1—S9V2C20004PSAA/S9V2C20004PSAAPurnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Setting Outdoor (CFM/ 0.1 0.3 0.3 0.7 OS ton) Cooling450 CPM 1125 1125 1125 1125 1125 CFM/Ton Watts 1.73 1.78 236 296 3611 Cooling 420 CFM 1050 1050 1050 1050 1050 CFM/Ton Watts 104 156 210 258 324 Cooling 400 CFM 1000 1000 1000 1000 1000 C'FM/1on Watts 93 142 105 251 309 Cooling 370 CFM 915 925 925 925 925 CFM/Ton Watts 77 123 173 226 i 282 Cooling 2.5 Tan —........_ _....... Cooling 350 CFM 825 875 875 8/5 875 CFM/Ton Watts 68 1.12 160 21.1 265 Cooling 330 CFM 825 825 825 825 825 OEM/Ton — Watts 60 102 147 196 249 Cooling 310 II:FM 775 775 775 775 775 CFM/Ton Watts 52 92 135 183 234 Cooling 290 CFM 225 25 725 725 725 CFMfTon Watts 45 83 125 170 220 Cooling 450 CFM 1350 1.350 1350 1360 1350 CPM/Tan Watts 194 259 326 396 468 Cooling 420 CFM 1260 1260 1260 1260 1260 CFM/Ton Watts 153 224 267 353 421 Cooling 400 CFM 1200 1200 1.200 1200 1200 CFM/Ton Watts 144 202 263 327 393 Coolin4370 CFM 1110 1130 1110 1110 1110 CFM/Ton Watts 119 173 231 291 354 Cooling 3.0 Ton Cooling 350 CFM 1.050 1050 1050 1050 1050 CFM/Ton Watts 104 156 21(1 26a 329 Cooling 330 CFM 990 990 990 990 990 CFM/Tan Watts 91 14D 1.92 247 306 .... .. - Cooling 310 CFM 9311 930 930 930 930 CFM/Tan Watts 78 12S 174 228 284 Cooling 290 CVM 870 870 820 8'70 870 CFM/Ton Watts 67 1.1.1 1.58 209 264 59V2C100U4-SUB-1'EN 5 Heating and Cooling Airflow Tables Table 2. S9V2C100U4PSAA/S9V2C100D4PSAA Cooling Airflow(continued) S9V2C10004PSAA/S9V2C100D4PSAAFurnace Cooling Airflow(CFM)and Power(Watts)vs.External Static Pressure with Filter Airflow External Static Pressure Cooling Unit Setting ... -...... _... Outdoor (CFM/ 0.1 0.3 0.5 0.7 0.9 ton) Gaoling 439 - CFM 1575 1595 1575 15/5 1575 CF Mjion Watts 289 :163 440 519 600 Cooling 420 CFM 1470 1470 1470 1470 1470 CFM/Ton Watts 241 311 383 458 } 535 Cooling 400 CPM 1400 1490 1400 1400 1400 CFM/Ton Watts 213 280 349 0.21 4q5 Cooling 370 CFM 1295 1.295 1295 1.295 1295 CFM/Ton Watts 175 237 302 369 439 Coaling 3.5 Ton Cooling 350 CFM 1225 1225 1225 1225 1725 CFM/Ton Watts 162 213 293 338 405 Cooling 330 CFM 1155 1155 1155 1155 1155 CPM/Ton Watts 131 187 247 308 373 Cooling 310 CFM 1005 11)85 1085 1085 1085 CFM/Ton Watts 1.13 166 222 281 343 Cooling 290 CFM 1015 1015 1015 1(115 1015 GPM(Ton Watts 96 146 194 756 315 —_ Cooling 450 CPM 1900 1800 1800 1800 CPM/Ton Watts 410 494 580 669 695 Coaling 420 CFM 1680 1660 1680 1680 1680 CFM/Tan Watts 342 420 507 585 671 Cooling 400 CFM 1600 1000 1600 1600 1500 CFM/Ton Watts 301 376 454 534 917 Cooling 370 CFM 1480 1480 1480 1480 1480 CFM/Ton Watts 246316 Cooling 4.01on et _ 389 464 Sol Cooling 350 CFM 1400 1100 1400 1400 14110 CFM/Ton ml Watts 213 280 349 421 495 Cooling 330 CFM 1320 1320 1320 1320 1320 CFM/Ton Watts 183 247 313 381 452 Cooling 310 CFM 1240 1240 1240 1241) 1240 CFM/Ton Watts 157 216 279 344 412 CooiInq 290 CPM 1160 1160 1160 1160 1160 aMjion Watts 133 189 248 310 .3 P5 *1 Fat toy Setting 6 59V2C10004-SUR--1-EN General Features NATURAL GAS MODELS ENERGY EFFICIENT OPERATION Central Heating furnace designs are certified by the Furnace is certified by the manufacturer to leak 1%or American Gas Association for both natural and L.P.gas. less of nominal air conditioning CFM delivered when Limit setting and rating data were established and pressurized to.5"water column with all inlets,outlets, approved under standard rating conditions using and drains sealed. American National Standards Institute standards. AIR DELIVERY SAFE OPERATION The variable speed blower motor has sufficient airflow The Integrated System Control is a solid state device for most heating and cooling requirements and will which continuously monitors for presence of flame switch from heating to cooling speeds on demand from when the system is in the heating mode of operation, room thermostat. Dual solenoid combination gas valve and regulator SECONDARY HEAT EXCHANGER provide additional safety. QUICK HEATING The S-Series furnace has a special type 29-4C'° stainless steel secondary heat exchanger to reclaim Durable,cycle tested,heavy gauge tubular stainless heat from flue gases which would normally be lost. steel primary heat exchanger quickly transfers heat STYLING to provide warm conditioned air to the structure.Low energy power vent blower,to increase efficiency and Heavy gauge steel and'wrap-around'cabinet provide a positive discharge of gas fumes to the construction is used in the cabinet with baked-on outside, enamel finish for strength and beauty. Every BURNERS orientation has at least two venting options.There are no knockouts on cabinet. Multipart Inshat burners will give years of quiet and FEATURES AND GENERAL OPERATION efficient service.All models can be converted to L.P. gas with LP conversion kit. The S-Series furnace utilizes a Silicon Nitride Hot INTEGRATED SYSTEM CONTROL Surface Ignition system,which eliminates the waste of a constant burning pilot,The integrated system control Exclusively designed operational program provides lights the main burners Upon a demand for heat from total control of furnace limit sensors,blowers,gas the room thermostat.Complete front service access. valve,flame control and includes self diagnostics for a.Low energy power venter ease of service.Also contains dry contacts for EAC and HUM. b.Vent proving pressure switches. S9V2CIDOU4-SUB-tEN 7 Features and Benefits 98.0%AFUE ACROSS ALL MODELS Last six errors stored Meets utility rebates Dry contact EAC and HUM connections Lowers utility bills All Molex connections;no spade terminals ELECTRICALLY EFFICIENT Low voltage labeled above and below Efficient airflow design reduces electrical energy use Rain shield over IFC keeps condensate off the control 34 INCH TALL TUBULAR STAINLESS STEEL PRIMARY HEAT Lighter,easier to move and fit into tight spaces like EXCHANGER short basements or tight closets 29-4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Works great with larger,high-efficiency coils Stainless steel is a more durable,corrosive-resistant No knockouts material than aluminumized steel 3-WAY MULTI-POISE/DEDICATED DOWNFLOW Integrated rail system for easy access if required 9 SKU's- Upflow/Horizontal Left/Horizontal Right Reduces or eliminates need for baffles 7 SKU's- Downflow VORTICA II BLOWER,DESIGNED EXCLUSIVELY FOR Added application flexibility and reduction in THE S-SERIES FURNACE specification errors Improved airflow efficiency AIRFLOW Durable,easy to clean,two piece housing At least 400 CFM/ton at 0.5 in.H2O external static Single piece belly band/motor arm assembly pressure;setup airflow options down to 290 CEM/ton REGULATORY Blower deck has full-length rails for easy removal and replacement, regardless of poise All models are air tight;1%or less air leakage as per THREE-WAY MULTI-POISE(UPFLOW.HORIZONTAL ASHRAE 193 LEFT AND RIGHT)PLUS DEDICATED DOWNFLOW Open vestibule design provides a full 34"high open Easier to specify vestibule Shipped ready to install no kits required) DIMENSIONS Every model has at least two venting options Widths are industry standard:175",21'(and 24.5" When in horizontal,trap extends only about 2" Depth remains approximately 28" Barbed fitting on trap at hose connection and on Cabinet will be compatible with industry standard coils, cabinet transition for hose has barbed fitting and as well as,other accessories clamps at both ends for leak resistance. INTEGRATED FURNACE CONTROL Vent table improvements including longer vent lengths; Setup l Status/Diagnostics/Digital Display 2"pipe can be used up to 100K No dip switches a S9V2C100U4SUB-1-EN E Sus ® Intertek The manufacturer optimizes the performance of homes and buildings around the world, A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, arid parts. For more information,visit www.IRCO coat. The menotao1urer has a policy of continuous.product and produm nate improvements and reserves this HO In change design end specifications without nonce, S2015 Irene s9v2C1001.14-su8-1 iEN 24 Feb 2016 p Enp»rmdearnewl COI"Ingersoll Rand ss 1 't 3 4TXC-DS-SUB-3 TAG: SUBMITTAL 4 - 5 ton ComfortTM Coils, Split System Aluminum Heat Pump / Cooling Coils Cased Upflow/Downflow Horizontal 4TXC-DS Series Coils Outline Drawing for Models: 4TXCD008DS3. 4TXCDO1ODS3 _. I 3:8 L..... y onosimmumbh L 4 `1 4 E 1 {_ � /— .m 18-I/8 i 08E8 NG Iry WRAPPER 9 ?I-I/2 FIGURE C MODE 4TX0000SDS3 4TXCDOIODS3 WEIGHT(IRS.I -3 From Dwg. D345686 RevA FRIGERANT CONTROL TX! e HE GHT A ONI It OVERALL WIDTH a-I N 24 1 2 -. OPENING WIDTH^C (INI _ 25 8 30 1 16 TOP OPENING•D 22x'4 22-3/4 GAS CONNECT I ON 7/8 LIOUID CONNECTION 3/S MATCHED FURNACE WIDTH wIR O ADAPTER REQUED) 241.2 DRAIN PAN PLASTIC ©2016 Ingersoll Rand All Rights Reserved Mechanical Specifications General These coos are A.R.I.certified with American Upflow, Downflow, or Horizontal coils shall be designed for cooling and heat Standard Heating&Air Conditioning's matching pump applications. The coil shall be 3/8" seamless aluminum tubing me- condensing units. chanically bonded to aluminum plate fin. Accessories Refrigerant for the 4TXC-DS coils shall be controlled with factory installed Evaporator Defrost Control installed on coil for Non-Bleed TXV refrigerant control. Refrigerant connections are brazed fit- lower ambient operating conditions. tings with an additional Schrader Valve for system service. The coil cabinet shall have a removable front and interior access panel for evaporator coil entering air surface cleaning. The coil includes a drain pan with drain connections for vertical or horizontal operation and a horizontal auxiliary drain pan. PRODUCT SPECIFICATIONS --- SPLIT SYSTEM HEAT PUMP / COOLING COMFORTTM COILS CASED UPFLOW/ DOWNFLOW/ HORIZONTAL 4TX00006DS3HCA 4TXCDOIODS3HCA INDOOR COILTypePLATE FIN PLATE FIN Rows/FPI. 3114 ane Face Area{s4 .1 6-00 7.00 Tube Size 38 3/8 Relrigeranl Control(No Non-BieedTXV Non-BleedTXV Internal check valve) Drain Conn.Size(in) 3/4 NPT 34 NPT Duct Connections See Outline Drawing See Outline Drawing REFRIGERANT R.410A R-410A CONNECTIONS BRAZED BRAZED Line Size--Gaslin.) 718 ]IB Line Size-.Liquid(m.) 3.8 3/8 DIMENSIONS en.) HXWXD HXWXD Crated W x D) 30-50x 27-12x 26-112 34-12x27-112 x 26-t2 Uncrated 26-7/8 x 24-1,2 x 21-1/2 30-3/4x24-112x21-1'2 WEIGHT Obs) Shipping Net 72/64 81173 {1]These indoor coils are A.H.R.I.certified with various split system air conditioners and heat pumps(A.H.R.I.Standard 210/240). Refer to the Split System Outdoor product information site or www.ahrinet.org PRESSURE DROP CHARACTERISTICS FOR COOLING AND HEAT PUMP COILS AIRFLOW(CFM)VS.PRESSURE DROP PRESSURE DROP(INCHES OF WATER COLUMN) Model 05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 4TXCD008DS3HCA 580 870 1100 1300 1485 1650 1805 1950 4TXCDO100S3HCA 555 835 1065 1265 1445 1615 1770 1915 Library Unitary since the menuteautu eat z oolq of continuous product and Product Section Coils oreduCt data improvement n.eservesthe right bchange epecifCa Product Coil hone and design=mph naive _.. Model 4TXC-DS Literature Type Submittal Ingersoll Rand o �l� Date 01/16 6200 Troup Highway ,-,,, File Na 4TXG-DS-SUB-3 us Tyler,TX 75707 Incertek Supersedes New i• Submittal 5 Ton Convertible Air Handler TAM7B0C60H51SC— Standard Coil TAM7B0C60H51EA— Black Epoxy Coil • • It U L 411 TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up.and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.improperly installed,adtisted m altered equipment by an unq affied person could resSi m death or seamen injury Unman working on he equipment,observe an precautions in the literature and softie tags,stickers,and Iabeialhat are attached lathe equipment. February 2015 TAM7A0C60-SUB-1H-EN (1*Ingersoll Rand Outline Drawing I 5 u x 5.551- 1 5 � 1 n x 121110066°6W' rui[ uaTO` a °°°1•11 or SIDES 11011 miillie°• •S (REWIRED) DiE n r«i < W¢ir Ne, a� L Minn mis WS 1.50 F 5oa 'Aa LINE"' / LIQLL1111SEE TABLE 0 3:9 I organ p A B IllIII 1 so anN _ sa� - R)5 315 sa. I. _ M V .1;_i:I i`\L 1 511 MODEL NO. A S C D E F H FLOW GAS LINE LIQ LINE CONTROL BRAZE BRAZE TAMI80C608515C 61.7 51.5 20.5 23.5 20.5 10.3 24.9 UV 7/8 3/8 TA187B0C60M51EA 2 TAM1A0C60-SUB-IH-EN PRODUCT SPECIFICATIONS cc a -•ATXNGSrE /PH/HL 200-230/1/60ATINGS fa, See D.C.Specifications - - COIL-Type Plate Fin Rows F.P.I.Rows-F4-14 Face Area(sq.ft.) 596 uhe Size tCo 3/8 Refrigerant Central FF.V Oram Conn.size pad"l 3/4 NET DUCT CONNECTIONS See Outline Drawing INDOOR FAN-Type Centrifugal Diameter-Width(in.) 11x10 No,Hoed - Drive-No.Speeds Direct-Venerate CFM vs,in.w.g. See Fan Performance Table N0.Motors-H.P. 1-1 Motor Speed RPM Variable ECM Volts/Ph/Hz 206-730/1/60 F.L.Amps 55 FILTER Filter Furnished' No ype Recommended Throwaway No,-Size-thickness 1-22 x 20-1 in. REFRIGERANT R-41O1 Ref.i.me Connections Brazed - Coupling or Conn.Srze-in.Gas 2/8 Coupling or Conn.Sire-In.Liq, 3/8 DIMENSIONS HxWxD Crated(In.) 62-3(4x25-I/4 x 23-1/2 aerated 61-11/16x23-1/2x21-3/4 - WEIGHT Shipping(Lbs.)/Net(Lbs.) 175/163 r=) These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps(AHRI STANDARD 710/240). Oa) 3/4"Male Plastic Doe(Ref. ASTM 1705-76) ,Mk'''.,-, AsPl 1 , e r r.l EA'.MIX":'s,.::. a"- .s`'* ..;Y a-:,. 240 Volt 208 Volt Heater Model No. No.of Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Circuits kW STUN Amps per Circuit Overload kW BTUH Amps per Circuit Overload Circuit Ampacity Pmtectitln Circuit Ampacity Protection No Heater _ 0 - _ 5.5*" 7 15 - - 5.5"" 5 15 BAYEVAC04++1 1 3,84 13100 16.0 27 30 2.88 9800 138 24 15 BAYEVAC05++1 I 4.80 16400 29.0 32 35 360 12300 17.3 29 30 BAYEVA008++1 1 7.68 2620032.0 47 50 5.76 19700 27.7 41 45 BAYEVAC10++1 _ 1 9.60 32800 40.0 57 60 7.20 24600 34.6 50 50 BAYEVAC10LG3 1-3 P11 9.60 32800 23.1 35 35 7.20 24600 20.0 31 35 BAYEVRC151G3 1-3 PH 14.40 42000 34.6 49 50 10.80 36900 30.0 44 45 BAYEVBCISBKI-Clrcult P:/ 2 9.60 32800 40.0 57 60 7.20 24600 34.6 50 50 BAVEVBCt5B81-CVafrt 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 BAYEVBC20BKI-Cirb.rit 1 9.60 32800 40.0 57 60 7.20 24600 34.6 50 50 BAYEVBC20BK1-Circuit 2 2 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 BAYEVCC25BK1 rid-Circuit 1 9.60 32000 40.0 57 60 7.20 24600 34.6 50 50 f"IBAVEVCC25BKI-Circuit 2 3 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 13AYEVCO25BK1-CrmR 3 4.80 16400 20.0 15 25 3.60 12300 17.3 22 75 1. "Motor Amps 2. See Air Handler nameplate for additional information. 3. Heater model numbers may have additional suffix digits. "r MCA and MOP for°mutt 1 contains the motor amps or Header not quatfted for 208V when installed in benzoate.ief position wltfe S Hear Pump- TAM7AOC6O-SUB-1H-EN 3 ., , it:° f�1"1* . TING ) ZI -: OUTDOOR COOLING rXT RNAL TATIC PR UR (C . tCFM/C.-` t T. .•�] HEATING MDLTIPLIER AIRFLOW AIRFLOW AIRFLOW AIRFLOW (TONS) SETTING Pow Ea SEITTNG PowER ,`.{ ' 370 CFM 1316/1904 1328/1330 1328/1244 1320/1146 1308/1033 400 CFM • 1909 mr;1929 3926 1919 1910 CFM/ton Watts 194/201 258/234 319/260 364/216 4306/280 CFM/tan Watts 205 275 33) 391 440 3S tons n 19661328988 .°. 390 CFM 1381/ 1391/1394 1390/1312 138383/1220 13)0/1115 420 CFM 146) 198] 1489 1982 1474 CFM/[on Watts 220/225 28 /260 344/28] 396/304 439/310 CFM/ton watts 230 303 367 423 474 rn t a 'n 370 CFM 1485/1583 1993/1516 1493/1491 1486/135) 14)5/1263 p 900 CFM 1586 1600 1604 1601 1592 CFM/[on Watts 269/2)8 337/319 398/392 452/362 498/370 CFM/te11watts 285 360 as 9282140:kr 490 543 F: 4 tans 390 • CFM 1557/1654 1564/1589 1564/1516 1559/1436 1598/1347 420 CFM 1659 16]2 16]] 16]5 1667 CFM/[on Watts 306/313 376/350 440/3]9 496/400 544/409 CFM/tan Watts 322 399 471 535 591 3701 CFM 1652/1148 1659/1685 1660/1616 1655/1540 1646/1456 400 CFM 1769 1782 1789 1788 1783 CFM/[on ta watts 360/365 433/403 500/433 559/454 610/465 CFM/tan Watts 385 467 543 611 671 4.5 tuns "tlielailati .. , . s L'44;3 6 390 CFM 1736/1831 14742/17470 1144/1703 1)40/1629 • 1732/1549 920 CFM 1854 1869 1815 1871 1872 CFM/Lon Watts 413/416 489/454 558/484 620/506 673/518 CFM/ton watts 439 525 604 676 )39 iv. trjt: 370 CFM 1826/1921 1833/1862 1835/1791 1832/1726• 1826/1650 p 400 Csi,FM 1963 19]8 1985 1988i. 1985 CFM/ton Watts 475/476 555/515 627/545 692/568 748/580 CFM/ton Watts 515 606 689 766 833 via .541934.-tiiiiiirigWillt.4say.. ...424).4 X. rIllile•GtiK 'jet 53999 390 CFM 1924/2021 1932/19)61-1193‘i/1900 1933/1832 1927/1758 920 CFM 2066 2082 2090 2093 209r0 CFM/ton Wats 551/550 634/588 710/619 777/641 him 836/654 iitorCFM/ton Watts 595 691 779 859 928 Mg :.. 593/S'n+: . R0 ';; : + ". • t Factory Setting If[M1e air ohandled lied In tlownflow or horizontal confi ' • "Not an actual OD size Sapp guresu ns, waelr blw • Status LED will blink Once per 100 CFM requested.In torque mode,actual airflow may be • Ano eating modetl default Ctto onsan above 2000 CFM could result in water blow-o8. lower. All heating modesusre with w ConstantCFM no. • Torque mode will reduce airflow when static is above a Cooling alrFlow values are wet coo,no filter ppro*)mately 0.4"water column. W H IJ,':GIFSsi:Lr)JiS SI^.Lia:�;l iii>�TSi,cti.:° BAYEVAC04BK1 MODEL NO. BAYEVACO4LG1 BAYEVACO8BK1 BAYEVAC10BK1 BAYEVAC1OLG3 BAVEVCB15LG3 BAYEVBC158K1 BAYEVBC2OBK1 BAYEVCC25 BN1 BAYEVACO56K1 BAVEVACOBLGI BAVEVAC10LG1 y BAYEVAC05LG1 Oa TAM7BOC60 1063/1]88 1063/1500 1125/1500 1000/1188 1125/1563 1250/1625 1500/1750 1625(01/1813 3 D m Note:Minimum auxllla heating airflow isautomatically configured by Me air handler model andthe auxiliary heater model number. This is not field adjustable. : Heater11ot qual filth for ZOSV when installed in horimntal left pposldOn without Heat Pump r C tii2 Features and Benefits • Unique cabinet design • Mortice®blower with polarized plug connections 2%or less air leakage and integrated slide deck for easy removal - Precision applied —durable door seals • Aluminum coil with integrated slide deck for easy removal and polarized plug connections on coil EEV - Specially designed air seal around refrigerant, • Patented enhanced coil fin condensate and conduit connections • Electronic Expansion Valve(EEV)with low ambient - Double wall foamed cabinet system and low superheat compressor protection - R-4.2 insulating Value(Avg Insulating Value R- • Dual refrigerant compatible as shipped 8.2) • Slide in electric heaters with polarized plug connections(sold as accessory) - No loose fiber design • Slide in hot water coils with polarized plug - Smooth cleanable interior design connections(sold as accessory) - Sweat eliminating design • UVC light kit with safety switch and polarized plug connections(sold as accessory) - Composite foamed cabinet doors • Labeled panels and connections - Water proof cabinet design • Molded in 1" standard filter rail - Integrated horizontal drain pans • Variable speed ECM motor - Modular cabinet • Soft start fan motor operation • Multi-position up/down flow horizontal left/right • Comfort RH'mode • Side return option(sold as accessory) • Built In fan delay modes • • Control board protection pocket built into cabinet Maximum width of 23.5" wall • Compact 20.8"depth with doors removed • Pre-marked Conduit Connection Locations • Pused 24v power • Alert port to view control board codes without door Salary door switch removal • 5 Year Warranty • Alert code notification • 10Year Warranty Registered • Low voltageterininal connection point • Optional Extended Warranty Available • Phillips head door fasteners A Kai na-a CERTIF1E6., raiJn�� CERTIFIED., cAI� us eed a21<" Intertek The manufacturer optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.IRCO.com. The(Maul.anurer has policy of cornmoous product,ndpro®rot data improvements nprI reserves the del to change design and speolsearonswanout nee. :2o1s Wane iAM4A0C6O-SIIB9X-EN 11 Feb 2015 Supersedes TAM7AOCOO-SUe-1G-EN IFebr.ar 20141 CII Ingersoll Rand oTRANE` Submittal rf r 'f Split System Cooling 4.0 Ton 4TTR3048E1000N _ TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment The instal lation,stalling up,and servicing of beating,ventilating,and air conditioning equipment can he hazardous and requires specific knowledge and training.Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury.When working oe the equipment,observe all precautions in the la?rature and on the lags,stickers and labels that are aiMhvd rothe equiprnant August 2016 4TTR3048E-SUB-1B-EN (iR)Ingersoll Rand. • TRANS' ( SERVICEPANEL . C III �y ��� ) ELECTRICAL AND REFRIGERANT %/������I ) COMPONENT CLEARANCES a,KAA��� /, , PER PREVAILING CODES A /C� TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1624 IS FEET/ ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305112"1 FROM WAL L AND ALL SURROUNDING SHRUBBERY ONTW'O SIDES. OTHER TWO SIDES UNRESTRICTED ELECTRICAL SERVICE - K PANEL r !.) 85 Tn 22 i791 DIAHOLE _ 1Alt A LOW VOLTAGE P 28 1 /B1 DIA K.D.WITH 22717281 DIA HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL '1 POWER SURLY I E' 'y LIQUID LINE SERVICE VALVE H ID"FEMALE BRAZE - CONNECTION WITH 1C SAE 1L --j- t_ t FLARE PRESS TAP FITTINGS FIG1 K.O.FOR ALTERNATE ELECTRICAL ROUTING From Owe 0152828 GAS LINE 1/4 TURN BALL SF WILE VALVE, IDFEMALE BRAZED CONNECTION WITH 1/4-SAE FLARE PRESSURE TAP FITTINGA Model Base A B C D E F G H ) K 4TTR3098E 3 933 829 756 152 98 219 86 508 (36-3/4) (32-5/8) (29-3/4) 7/8 3/8 (6) (3-7/8) (8-5/8) (3-3/8) (20) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[d8(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTR3048D 74 72.5 72.3 69.2 67.5 729 60.2 55.2 54.2 Note:Rated in accordance with AHRI Standard 270-2008 For reference only66 4TTR3048E-SUB-IR-EN THANE' Product Specifications OUTDOOR UNIT(.)(b) 4TTR3048E1000N i) Certified in accordance with the Air-source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(C 208/230/1/60 a Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 28 (o) Rated in accordance with AHRI standard 270. BR.CM.PROT.RTG.—MAX.(AMPS) 45 i Calculated in accordance with Nati Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR CLIMATUFF®-SCROLL Mi This value shown for corn pressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1-1 Ms specification sheet is used to compute minimum branch circuit VOLTS/PH/HZ 208/230/1/60 selection anrreny d max.fuse size.The value shown is the branch circuit t. ) No means no start components.Yesmeans quick start kit R.L.AMPS Id)—L.R.AMPS 21.8-127 components.PTC means positive temperature coefficient starter. FACTORY INSTALLED in Standard Air—Dry Coil—Outdoor START COMPONENTS(=) NO s) This value approximate.For more precise value see Unit nameplate. rm Max.linear length 60fL;Max.lift—Suction 60 ft. Max.lift—Liquid INSULATION/SOUND BLANKET NO 60R.For greater length consult efrigerant piping software Pub.No. COMPRESSOR HEAT NO 32-3312-0'(*denotes latest revision). OUTDOOR FAN PROPELLER DIA.(IN.)—NO.USED 23—1 TYPE DRIVE—NO.SPEEDS DIRECT—1 CFM @ 0.0 IN.W.G.0) 3915 NO.MOTORS—HP 1—1/5 MOTOR SPEED R.P.M. 835 VOLTS/PH/HZ 200/230/1/60 EL.AMPS 0.93 OUTDOOR COIL—TYPE SPINE FIN'e ROWS—F.P.I. 1-24 FACE AREA(SQ.FE) 19.07 TUBE SIZE(IN.) 3/8 REFRIGERANT LBS.—R-410A(O.D.UNIT)WI 6 LBS.,7 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.O.GAS m: 7/8 LINE SIZE—IN.OD.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED(IN.) 42 x 30.1 x 33 WEIGHT SHIPPING(LBS.) 233 NET(LBS.) 197 4TTR3048E-SUB-1B-EN 3 • TRANE Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include:Centrifugal oil pump and low 115°F Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and Casing efficient heat transfer.The coil is protected on all four sides by louvered panels. Unit casing is constructed of heavy gauge,galvanized Low Ambient Cooling steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel.The As manufactured,this system has a cooling capacity to corner panels are prepainted.All panels are subjected 55°E The addition of an evaporator defrost control to our 1,000 hour salt spray test.The base is made of a permits operation to 40°F The addition of an CMBP-G30 weatherproof material to resist corrosion. evaporator defrost control with TXV permits low Refrigerant Controls ambient cooling to 30°F. Thermostats—Cooling only and heat/cooling(manual Refrigeration system controls include condenser fan, and automatic change over). Sub-base to match compressor contactor and high pressure switch.High thermostat and locking thermostat cover. and low pressure controls are inherent to the compressor.A factory supplied liquid line drier is Evaporator Defrost Control —See Low Ambient standard.Some models may require field installation. Cooling. p Et4 qe Intertek TRANE Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Cars,Ingersoll Rand°,Thermo King' and Trane"—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results.For more information,visit www.ingersollrand.com. Ingersoll Rand has a policy 0f continuous product and product data improvements end reserves the right to change design and specifications without notice. lN2012 Ingersoll Rand All rights reserved 4TTR3048ESUB-1B-EN 29 Aug 2016 p Supersedes 471,3048D-SOB-1A-ENmecember20141 �f1 Ingersoll Rand.