Loading...
36-371 171 EMERSON WAY BP-2017-0012 GIS#: COMMONWEALTH OF MASSACHUSETTS Map-Block:36-371 CITY OF NORTHAMPTON Lot: -001 Permit: Building Category:New Single Family House BUILDING PERMIT Permit# BP-2017-0012 Project# JS-2017-000027 Est. Cost: $510400.00 Fee: $2051.90 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: KENT PECOY & SONS CONSTRUCTION INC 052589 Lot Size(sq.ft.): 50616.72 Owner: KROTOWSKI RANDY&MARGARET Zoning: Applicant: KENT PECOY & SONS CONSTRUCTION INC AT: 171 EMERSON WAY Applicant Address: Phone: Insurance: 215 BALDWIN ST (413)781-7008 WC WEST SPRINGFIELDMA01089 ISSUED ON9/8/2016 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT NEW 3209 SQ FT SINGLE FAMILY HOME WITH ATTACHED 3 CAR GARAGE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House ft Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signature: FeeTvpe: Date Paid: Amount: Building 9/8/2016 0:00:00 $2051.90 212 Main Street. Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck-Building Commissioner Fite# BP-2017-0012 �,z ell l APPLICANT/CONTACT PERSON KENT PECOY& SONS CONSTRUCTION INC %p{r(,� ADDRESS/PHONE 215 BALDWIN ST WEST SPRINGFIELD (413)781-7008 PROPERTY LOCATION 171 EMERSON WAY MAP 36 PARCEL 371 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILI ED OIJ Fee Paid a, a5/, 90 Buildim,Permit Filled out Fee Paid TypeofConstruction: CONSTRUCT NEW 3209 SQ FT SINGLE FAMILY HOME WITH ATTACHED 3 CAR GARAGE New Construction Non Structural Int Dor renovat/o s Addition to Existing Areossory Stm tore Building Plans Included: Owner/Statement or License Q2539 3 sets of Plans/Piot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:* Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance' _ Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management 4L< I n Delay . Y,/7 Signature of Building Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning& Development for more information. `3 Nsr 411/4 t\ Department use only Oce y ; City of Northampton Status of Permit: �R, Building Department Curb CWDriveway Permit #4.9 212 Main Street Sewer/Septic Availability •eRoom 100 Water/Well Availability "� Northampton, MA 01060 Two Sets of Structural Plans d hone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify AP C, ION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1-SITE INFORMATION 1.1 Property Address: This section to be completed by office (\ _ Np n 11.1 EI'n ER CI\i WA)/ Map Lot Unit CRT/-kp N1t' 1-61•A AAI CAC (. Zone Overlay District / fly Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 7.1 Owner of Record: J),04 RNCS MARGARQT YCRCJVGL)SKI `C/ Mush Sr 1 CRiftNMP7Ct4 NIA OIOIrC Name(Prig% Current Mailing Address: lC � Telephone Signature 2.2 Authorized Anent: tcel•I pe-i AN11.SCN!S ccINcTRucti t,t4 It.1C. � Ea Jt. ' - f S • .. Name(Print) r Current Mailing Address: �� — � -- (413) '7y:1- 73 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 1140 HOG CG (a)Building Permit Fee 2. Electrical 7_5 000 (b)Estimated Total Cost of Constmcdon from(6) 3. Plumbing Z. I l c o 0 Building Permit Fee 4, Mechanical(HVAC) y,., 000 5.Fire Protection 6. Total=(1 +2+3+4+5) 510 9 ne Check Number ,7j„A 6-/ a?osj. 9O This Section For Official Use Only Building Permit Number Date Issued: Signature: Building Commissionedlospedor of Buildings Date Section 4. ZONING All Information Must Be Completed, Permit Can Be Denied Due To Incomplete Information __® Ruired by ning Tb,,eqcolumn m bZoe f hed n by Building Dparnnent ®-- Setbacks Front, `lq Side .: W.' it: 43` Rear Open Space Footage =MEE pp (Lot area mines bldg N<vaved p5,7 DrkinD A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO T" DONT KNOW O YES O IF YES,date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES 0 IF YES: enter Book Page andtor Document if B. Does the site contain a brook, body of water or wetlands? NO CO DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES © NO 0 IF YES, describe size, type and Location: 0. Are there any proposed changes to or additions of signs intended for the property? YES O NO IF YES,describe size, type and Location: E. Will the construction activity disturb(clearing,grading,excavaboo or filling)over 1 acre or is it pad of a common plan that will disturb over 1 acre? YES O NO iF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Lal Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors D Accessory Bldg. El Demolition ❑ New Signs [O] Decks ID Siding[Dl Other[OI Brief Description of Proposed Work:(ptVATRULT ti6VJ 32-,`1S a.FT SINi FAIHU'1 hthp\e h111^I kTIM H& Tt4REe CJP CAP-AL Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a.if New house and or addition to existing housing,complete the following: a, Use of building_One Family K, Two Family Other b. Number of rooms in each family unit: Number of Bathrooms �- ' 5 c. Is there a garage attached? yCS d. Proposed Square footage of new construction Dimensions e, Number of stories' L f. Method of heating? FOR(6t Alfa Fireplaces or Woodstoves (j/AS Number of each _ g, Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction b i. Is construction within 100 ft of wetlands? Yes X No. Is construction within 100 yr. floodplain XI Yes No j. Depth of basement or cellar floor below finished grade 7 k. Will building conform to the Building and Zoning regulations? r+ Yes No I. Septic Tank_ City Sewer X Private well City water Supply X SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT RAN]}'Y KR.Pin W .as Owner of the subject property hereby authorize 1f.M( ('£tti/ ft N6 SOO CUR1TY.U(2TiCt1 tNC. to act on my behalf, in all matters rein ive to work authorized by this building permit application. 'Vs/ Signature of Own Date ,t{bAM RtNAGJ ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief, Signed under the pains and penalties of perjury. AMM RENAUD Print Name 2 Signature of Owner/Agent Dat SECTION S-CONSTRUCTION SERVICES 8.1 Lice :ed •nstru tion : •e 1,r: Not Applicable ❑ Name of License Holder LE _ ____ CS- O5L5P;`1 License Number 21NS WES -,E16LAS A ClorA elf(el L � G17 Address Entree Date "4". `i 3 7 -700'. Signature Telephone 9 Rea'steretl Hame Improvement Contractor: Not Applicable ❑ En;T 6 - ' : -.'z /Their or.3 .'c [L7 *7 ___ Company Name Registration Number Z-15 CAta ,/ hi .ST. e.' s • ti &L M 71311Z( IL, Address Expiration Data _sie-.er , _ _. Telephone(y 1 3)7 ILe9 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.I.c. 152,g 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes__... No 0 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who docs not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 105.3.5.1 Definition of Homeowner Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to he,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be congidered a homeowner. Such"homeowner'shall submit to the Building Official,on a form acceptable to the Building Official that he/she abaft be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued_ Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter'153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you maY be liable for person(s) you hire to perform work for you under this permit. The undersigned`homeowner'certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature `,,,,- MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton, MA 01060 587-1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 171 Emerson Way, Lot 23 Inquiry Made By: Adam Renaud Kent Pecoy &Sons 413-654-6364 Date of Inquiry: 585-8482 Fire Line Irrigation (Domestic X Number of Units: Type of Single Family X Type of Private X .I Unit(s): Apart. Comm. Ownership: Condo Multi-family Rental (Annlicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Yes: No: site? Yes: No ,-tit Size of Water Maim C\ Material: D J Age: i .'s Approximate Static Street Flow Test Conducted:Yes: No: Pressure: If done attach results f e C. r.<_ Size of Service Connection / .�fiS f::^3 r el F i�`7. • G . Telc Suggested Meter Size: / ( "��Y� 1C. ' Oh'- S" ,-- t"c t , P Comments: The Water Department cannot guarantee dequate water pressure during peak demand _ 0:e times at elevations above 320 feet. 1,✓A 1 r i-z, ics. Hz-2) fA \/.A\ L..,4J LE. G�A "'�9c— rj'rcl_,7{jt. poi, F 'fl r-' ' ; c -;4m. pr Tyr +.�rte re- f. • A corresponding water entrance fee shall be paid prior to making any connection to the municipal wat .. , _ 4. system. • Arrangements of such installation shall be made with the Northampton Water Department with a minimumc' 'C ofworking days notification. _ ry Ali work shall co fo t Northampton Water Department specifications. Jam') DPW Engineering Dept. Water Entry$ ' Meter$ J1 0 Radio $ /J S cc: City of Northampton Building Dept./Commissioner Note: If this availability is for a new construction,it must be hand delivered to the Building Inspector. ,1 MUNICIPAL SEWER/AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587-1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 171 Emerson Way, Lot 23 Date of Inquiry: 6114116 Adam Renaud/Kent Pecoy & Sons 413-654-6464 Reason for Request: New Construction Municipal Sewer Main in Front of Location: Yes No Municipal Storm Drain Available: 5 '/: deep Yes No Size of Sewer Main: Material: Age: Depth of Sewer Main: Length of Sewer Main: Size of Service Connection: Type of Service Connection: Tie-in to Sanitary Main Tie-in to Sanitary Stub • Comments: Trivat2 Seinip,/ IIn-. - Set Up bmi �in City Requires 6" cleanout installed at City Property Line Note: If this availability is for new construction, this form must be hand delivered to Building Inspector. A corresponding"sewer entrance fee"shall be paid prior to making any connection to the municipal sewer system.Arrangements of such installation shaN be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department pecifirations. cc: City of Northampton Building Dept I Commissioner ACORD CERTIFICATE OF LIABILITY INSURANCE DATE IMMMORTn1 7/6/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement, A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). ONTAtt PRODUCER Irene $alis® xHON --_ Borowski Insurance Cyd E41. (913)586-5011 NM;mvlse6->sa 88 King Street, Suite B IPORtSS ibaliaeeborawakiinsurance.com INSURER(S)AFFORDING COVERAGENA10% Northampton MA 111060-3257 wsuReRA:Netherlands Insurance 129171 INSURED _ .—. p15yRER a/Excelsior Insurance '.11045 Rent Pecoy & Sona Construction, Inc INSURER CF8erless Insurance Company 215 Baldwin St INSURER AIM Mutual INSURER E: Nest Springfield MA 01089 INSURERF: COVERAGES CERTIFICATE NUMBER:16-17 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. - 'AbDLSUM� POLICY SW _— LIMBS — ILSR WVO POLICY LTR TYPE LGENERINSURANCE IHSO POLICY NUMBER IMWpDM'YTl (MM,nOJ{YYYti X COMMERCIAL GENERAL LABIUM' I IEACH OCCURRENCE i$ 1,000,000 AGE a RENTED 100,000 A I CLAIMS-MADE OCCUR PSL SES(EB cu n51 & -CHFB'+80556 "701/2016 ; '1/1/2017 MED EXP, y P0990 $ 5,000 ,,. PEH50NAL&ADE IrvJUNV $ 1,000,000 GENU AGGREGATE LIMIT APPLES PER'. t GENERAL CGREGATP. $ 2,000,000 RDC" PRODUCTS-COMP/OP AGG $ 2,000,000 X POLICY /ECT _� L01, E I OTHER .. _ MIRMIOBILEUARM1itt c CQM01NeenVmuGCE LIMIT IE 000.000 I _IgNYAUTO 'BODILY INJURY(Per per009 E —B ALL OWNED ( X SCHOs •D 9A7023T84 011/2016 7/1/2016 BO'OILY INJURY(Pet CCM? $ — — I.. .AUTOS - NON-OWNED i PRIWE DAMAGE X HIRED AUTOS R_ AUTOS Pe c bend- — $ IX UMBRELLA UAB X OCCUR i _EACH OCCURRENCE _ $ 5,,000,000 c t MESS MAO CIAIMSMADE ACGREGATE S 3,000_000 _ I DED I X RETENTIONS 10,000 CUa7836S1 7/1/2015 7/1/2017 IS �WORXERS COMPENSATION PER STATUTE I IERH AND EMPLOYERS LIABIUTY - ANY PROPRIETOPIPARTNER%XECUTiYE LIN'NIA E EACH AcCCE)ENT $ 500,000 OFFICER/MEMBER EXCLUDED? D •(Mandalwy MNNI I MI280 DR 006023-2015A 6/30/2016 6/30/2017 kL DISEASE,EA EMPLOYEE$ $00,000 HrepCRing uOnc,PERATONS below • I EL OSEASEPOLICY UMIT I$ 509,000 I l I DESCRIPTION OP OPERATIONS I LOCATIONS/VEHICLES IACORD NM.Add/Ronal Remarks schedule,may be attached If more apace is required) CERTIFICATE HOLDER CANCELLATION _ SHOULD ANY OF THE ABOVE DESCRIBED POLICIES SE CANCELLED BEFORE City of Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 210 Main St ACCORDANCE WITH THE POLICY PROVISIONS. Northampton, MA 01060 AUTHORIZED REPRESENTATIVE /f R Hoy awski/BORZOI tS �G ©1988-2014 ACORD CORPORATION. All rights reserved, ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD INSa25/Pm4On The Commonwealth of Massachusetts u= = Department of Industrial Accidents t— Office of Investigations r4141-3-1,0 600 Washington Street � Boston, MA 02777 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(BusinessfOrganizatior/Individual): KENT PE-CO1 ANp Sotvi CANSyucTIoN 1 NiC Address: 115 Psoo-pini/' .STREET City/State/Zip: ?_SNI Ch J .t.1A _o 10 Phone #: (H13 7 1 700e) Are you an employer? Check the appropriate box: Type of project(required): 1.al am a employer with 3D 4. 0 I am a general contractor and 1 employees(MI and/or part-time).* have hired the sub-contractors 6, gNew construction 2.0 I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have $, ❑ Demolition working for me in any capacity. employees and have workers' [No workers' comp,insurance comp.insurance,- 9. ❑ Budding addition required.] 5. 0 We are a corporation and its I0.❑Electrical repairs or additions 3.❑ I am a'homeowner doing all work officers have exercised their 110 Plumbing repairs or additions myself [No workers' comp. right of exemption per MGL 12 ❑ Roof repairs insurance required.) o. 152, §1(4),and we have no employees. [No workers' 13.0 Other,,,,,,,,, comp. insurance required.] *Any applicant that checks box kl must also fill out the section below showing their workers'compensation policy information. Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that cheek this box must attached an additional sheet showing the name of the sab-coattatos and stats whether or not hose entities have employees. If the sub-contractors have employees.they must provide their workers comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below Ls the policy andjob site information. Insurance Company Name: 6CRAk‘,'SKi 1t>i td RA N;CC Policy#or Self-ins. Lie. #: W M Z SQ(.' flfl4.pz,3 - iOI-f A, Expiration Date: to/ 3u/2-C l kk Job Site Address: 17 ( 6M64S",tv WAY City/State/Zip: NLRTHAatPT2t4 MA Qty,+ Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify un rhepains and ties of perjury that the information provided above is true and correct. Signature: N �J' + Date: 7�{0�1� phone#: .131' 7421 " 7 O Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): I.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: I -7i ENEkser\; \Nips The debris will be transported by: ASSOCA fcc a4 '-p,rvv w'RecKeec The debris will be received by: krPOO SE TRRNwe-P s—AnoN Building permit number: Name of Permit Applicant KENT Pro/ ANI ror1rgdcnoL, �tiC Date Signature of Permit Applicant i. 1r1p Office of Consumer Affairs and Business Regulation 4.,x,.::. 10 Park Plaza - Suite 5170 Boston. Massachusetts 02116 Home Improvement Contractor Registration Registration: 107367 Type: Pnva'c Corporation Expiration. 7/31/2016 Tra 2545'7 KENT PECOY & SONS CONST. INC. Kent Pecoy 215 BALDWIN ST WESTSPRINGFIELD, MA 01089 Update Address and return card.\lark reason for change. Address Renewal Emilio?men( I Ca rd 011itt oflA RW min Again R Itminns Regulating License or istrat lid for indry idol use null HOME IMPROVEMENT CONTRACTOR before the expiration date. If found return ten 'Reg swat on: 107361 Type. Office of Cmsumcr Affairs and Business Regulation -';uz7) Expiration: 7.131/8016 nrmmc coivoiatm, 10 Park Plaza-Suite 5170 Busmen M A 112116 KENT PECOY fl SONS CONST INC Hem Pecs 215 BALeWIN SiI' / TT / — WESTSFRINGFIELD MA 0108.'v _adnwrr. ri:'^ Not valid without 'f —1// out signature Massachusetts Department of Public Safety ci Board of Building Regulations and Standards License: CS-052589 Construction Supervisor KENT W PECOY 215 BALDWIN ST WEST SPRINGFIELD MA 01089 Expiration: Commissioner 09/16/2017 Construction Supervisor Restricted to: Unrestricted-Buildings of any use group which contain fessthan 36,000 cubic feet(991 cubic meters)of enclosed space. Failure to possess a current edition of the Massachusetts State Building Code is cause for revocation of this license. DPS licensing information visit: W W W.MASS.GOWDPS Vreeland Design Associates An integrative approach to design engineering and site planning Date: August 15, 2016 To: Charles Miller Assistant Building Commissioner Northampton,MA 01060 From: David Vreeland,P.E. Vreeland Design Associates Re: Randy and Margaret Kmtowski, Lot 171 Emerson Way, Florence, MA: Proposed braced walls adjacent to garage doors. Dear Chuck, I have consulted with Jay Heilman, Project Manager, Pecoy Homes,on the attached garage corner bracing for the new residence at Lot 171 Emerson Way, Florence. Because of how the garage is integrated into the main house construction and the diaphragm action of the garage ceiling, I have determined that just the two outside corners adjacent to the double garage doors are needed to be reinforced for wind bracing. Jay has proposed using Simpson Steel Strong Wall Garage Portal System panels#SS W I2xs with high strength#S S W AB3l4x24 bolts,two per panel.The calculated tension load on the panels at a basic wind speed of 90 mph is 5.,625 lbs. The allowable tension load for the Simpson panel is 11,305 lbs. 1 certify that the Simpson Strong Wall#SS W I2xS panels bracing panels are in compliance with the structural requirements of the cull a it Mass State Building Code. Please contact me if you have any questions or need additional information. Sincerely, toot OP*44274 oVREELAND ot/ DAVID N. CS'w CIVIL David Vreeland, P.E. No.aWt7 Vreeland Design Associates 9foforµ od 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 629-3282 ( U Jaf N crtlittmptun O 5& sC , BRassarlfusefts r4TEfl/ Cf DEPARTMENT OF BUILDING INSPECTIONS 3p, w 212 Main Street • Municipal Building np Acor Northampton, MA 01060 I Aspit,roR Kent Pecoy&Sons Construction September 8, 2016 215 Baldwin Street West Springfield, MA 01089 Subject Location: 171 Emerson Drive Map Block: 36-371 Mr. Pecoy, Your building permit application with plans dated 6-23-16 has been approved as drawn and per this memo. All work must meet applicable codes whether or not included within this memo. Please follow up on the following items: These items will need to be accomplished as the project moves forward and before rough inspections; 1. Garage braced walls per engineer's letter. 2. Dormer framing per engineer's drawing. 3. A post footing will be needed for the inside corner of the basement stair. 4. A tempered window will be required adjacent to the active leaf of the patio door. 5. HERS initial and final ratings,duct blast results, and a signed Thermal Bypass Checklist. 6. Smoke, Heat and CO detectors throughout the structure to current building codes. 7. An emergency escape window is required within every bedroom, basement and walk-in attic. 8. An air barrier is required between the tub and the wall cavity. 9. If permeable insulation is used air sealing and an air sealing inspection is required at the exterior and interior skins.Typically the sheathing and drywall. Note:The 2012 IECC with MA amendments is the non-stretch energy code and the 9`h Edition Building Code and new Base Code and Stretch Code are begin July of 2016 with a concurrency until January 2, 2017. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. Read only international codes are available on line at http://publicecodes.cyberregs.com/icod/one must also consider the MA amendments to these codes which can be found at www.mass.gov/dps/bbrs . The current relevant building codes are: 2009 IBC, 2009 IEBC,2009 IMC, 2009 IRC, 2009 or 2012 IECC,AA115, MA amendments. 1. Structures shall conform to 780 CMR 8'h Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3.except those in group I soils(table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. or if high water table or severe soils waterproofing 780 CMR R406.2. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement.780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be%" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing. 780 CMR R406.1 see exceptions. 8. Emergency escape is required out of every basement whether habitable or not,each bedroom and walk- in attics.780 CMR R310.1 9. Crawl spaces can be treated in three different ways,vented (poor idea),exhausted (similar to exhaust only systems),or treating the space with supply and return. See 780 CMR R408 10. Ceiling joist are intended to prevent spread,once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8-16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. 11. Steel straps over the ridge or 1x4 minimum collar ties are required 4'OC in the upper 1/"1780 CMR R802.3.1 12. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 13. A complete window and header schedule is required.780 CMR Table R502.5 for header sizing and number of jack studs required. 14. Wood walls shall be capped with double plates to provide overlapping at corners and intersecting walls with bearing partitions,joints staggered 2' minimum. 780 CMR R602.3.2 a. Exception:A single plate may be used or plates may be excluded over lintels provided the plates/lintels are adequately connected by a 3" x 6" plate .036 galvanized steel nailed to each segment with 6-8d nails 15. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I-joist and or Floor Truss c. Roof truss 16. All I-Joist need to be protected from fire with'''A drywall or 5/8 wood structural panel. (R501.3) 17. A braced wall plan identifying appropriate braced wall areas where required (R301.1) and braced wall method being used.780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. c. When using PFH (R602.10.3.3) or PFG (R602.10.3.4)the nailing requirement is 4" and 3" respectively using 8d common nails or galvanized box nails. PNEUMATIC nails must be full headed with the temper and shank sizing meeting the strict code requirement. 18. When nailing sheathing make sure your pneumatic nailers' pressure is properly set. Nails set too deep perforate the sheathing weakening it and contribute to building damage in high wind events. 19. Ceiling heights minimum 7'for habitable spaces,6'8" for bathrooms includes tub/shower area if a shower head is used, 6'8"for basements, 6'4" at beams/ducts. 780 CMR R305.1. MA amended 20. Hazardous glazing locations, within 24" of a door,or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 21. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule.Order restrictork. 780 CMR R612.2 22. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape.780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size,Casement 20"x41" exception 5 sqft at 1"floor. Minimum clear opening 20"x24" or 24"x20".780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36", maximum step 7%" from the top of the threshold and only in-swinging doors. 780 CMR R311.3 23. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8''4",maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30"or less 780 CMR R311.7.4.3 Exception,4 3/8"on balustrade, 6" in the triangle. Graspable rail 1'X" minimum and 2" maximum rail, height minimum 34" maximum 38", required for4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. Rails must be continuous and returned to the wall if not to newel post.780 CMR R311.7. 24. Guards 36"minimum height above walking surface,a bench is a walking surface,required for more than 30"above floor or grade within 36",4" sphere rule.780 CMR R312.1. 25. Floor joist systems that are not equal to 1'/1" nominal dimension must be covered with Y" drywall or 5/8"wood structural panel or equivalent with some exceptions. 780 CMR R501.3 26. Educate the plumber and electrician about maximum notch and hole sizes,and placement.780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, or holes in joist are a maximum 1/3 the depth not closer than 2"from the top or bottom or to any other hole. Notches are different. 27. Drilling or notching of more than 50%of the wall plate width of an exterior wall or load bearing partition requires a 16 GA 11/2" strap across the area and 6" beyond each side with 8- 10nd nails. 780 CMR 8602.6.1 28. Where dryer ducts penetrate the wall they must be sealed with fire caulk.780 CMR M504,2 29. Dryer ducts must terminate outside of the building, have a backdraft damper, cannot include a screen, and require 3' clearance from windows, 780 CMR M504.4 30. Dryer duct transition is limited to 8' of aluminum flex, must be exposed, and the proper UL listing. 780 CMR M504.6.3 31. Dryer duct maximum equivalent length is 35' less 5'per 90°elbow or per manufacturer's specs. 780 CMR M502.6.4, no screwed connections use foil tape appropriate for the use. 32. Dryer ducts when concealed must have a permanent label or tag within 6'of the duct connection 780 CMR M502.6.5 33. Makeup air is required for dryers exhausting more than 200 CFM. 780 CMR M504.5 34. Makeup air is required for any exhaust hood over 400 CFM.780 CMR M505.2 35. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1"clearance for 5'from the duct outlet for all fireplaces and airtight doors. 2009 IECC 4024.3 36. Fire and draft stopping shall be completed before rough inspection.Typical locations,top (ceiling) and bottom (floor) plates, soffits, and every 10'within enclosed cavities. 780 CMR R302. 37. Ignition barriers are required over all thermal plastics and must be in place before final. 780 CMR R316. 38. Dwelling/Garage fire separation.An attached garage(within 3'of main structure)is required to have 34" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have''/:" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 39. Energy aspects shall comply with the stretch energy code.780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist, Duct blast testing when practicable. f. All band joist insulation must be enclosed within an air tight cavity, which you must create. 40. Vapor retarders.Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow(convection)a vapor retarder or barrier is intended to stop molecular moisture transfer(diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99%of the moisture in a structure.This is evident every time one exposes fiberglass insulation and finds black insulation, which has filtered dirt out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 41. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 42. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note:ThruLoks are engineered for post attachment supporting a railing. Lateral attachment is required for each deck per section 502.2.2.3. 43. Smoke and CO detectors as required.780 CMR R314 and R315. a. Smokes in each bedroom,within 10'of a bedroom door, and at the bottom of a stair leading to a finished floor above. b. CO within 10' of bedroom doors,at each level,for every 1500 sqft, (plumbing code in the mechanical room) Except if there are no fossil burning fuels or attached garage. c. Heat detector in attached garage, and other large unfinished unconditioned spaces. 44. Closets beneath stair which have doors must be drywalled with'A". 780 CMR R302.7 45. If there is mechanical equipment or a combustible root 30 sqft of space,and 30" measured from top of ceiling joist to bottom of rafters an attic access of minimum RO of 22"x 30" is required to be located in an accessible place. It must be insulated equal to surrounding, gasketed, and secured in place. 46. Clearances above gas stoves and cook tops burners is 24" to non-combustible or 30"to combustibles. Relevant items must be submitted to the building department for approvals before inspections and or Certificates of Occupancy can be issued. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday,8:30 am to 4:30 pm, excepting we dose for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller@northamptonma.qov Thank you forY�//uurrr operation onntthese matters. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement