Loading...
31B-106 (5) 10 BRIGHT AVE BP-2017-0345 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31 B- 106 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Categorv: shed BUILDING PERMIT Permit ft BP-2017-0345 Project# JS-2017-000565 Est,Cost: Fee:$30,00 PERMISSION IS HEREBY GRANTED TO: Const.Class_ Contractor: License: use iron ;_ Homeowner as Contractor__ Lot Sizetsa,ft.): 4$713,72 Owner: PACHUCKI MARK Zoning: URC(100)/ Applicant: PACHUCKI MARK AT: 10 BRIGHT AVE Applicant Address: Phone: Insurance: IO BRIGHTAVE (413) 341-3095 () NORTHAMPTONMA01060 ISSUED ON::9115/2016 0:00:00 TO PERFORM THE FOLLOWING WORK:96 SQ FT SHED POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 9/1520160:00:00 $30.00 212 Main Street, Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2017-0345 APPLICANT/CONTACT PERSON PACHUCKI MARK ADDRESS/PHONE 10 BRIGHT AVE NORTHAMPTON (413)341-3095 Q PROPERTY LOCATION 10 BRIGHT AVE MAP 31 B PARCEL 106 001 ZONE URC(I00)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid -47):) 7 T /litet ,;�4±/0)0Building Permit Filled out �r �J�J Fee Paid Typeof Construction: 96 SO FT SHED New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON 'FORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 9 6 City of Northampton sem. Massachusetts h$ �., rl i (A 212DEPARTMENT OF BUILDING INSPECTIONS o : "'Task P 212 Main Street • Municipal Building 2 �. �_- ' Northampton, MA 01060 CL.- SEP 13 A ESS,ORY_STRUCTURE PERMIT APPLICATION (For freestanding structures less than 200 sq. ft., at least 5 feet from any other structure) Z Check# U dl 2,f) PLEASE TYPE OR PRINT ALL INFORMATION 'W /vp \ 1. Name of Applicant: Mark C. Pachucki & Winslow Carroll (MARl &L4 i4Lizie;ffi€,Ct�M ) Address: 10 Bright Avenue Telephone: 413-341-3095 2. Owner of Property: same Address: same Telephone: 3. Status of Applicant: X Owner Contractor 4. Structure Location: shed in backyard of 10 Bright Ave Parcel ID:Zoning Map# Parcel # District(s) (TO BE FILLED IN BY THE BUILDING DEPARTMENT) 5. Use of Property: Single or Two Family: X Multifamily: Commercial: 6. Description of Proposed Structure: One Story Shed under 200 sq. ft.: X Freestanding Deck under 200 sq.ft., less than 30"above grade: SIZE OF STRUCTURE: 96 square feel Other(describe): 7. Attached Plans: Sketch Plan X Site Plan X Plot Plan X 8. Does the site contain a brook, body of water or wetlands? NO X DON'T KNOW YES IF YES: Has a permit been, or need to be, obtained from the Conservation Commission? Needs to be obtained Obtained , Date issued CONTINUED ON NEXT PAGE 9. ALL INFORMATION MUST BE COMPLETED: PERMIT CAN RE DENIED,j1UE TO (,ACK OF INFORMATION. This column to be filled in by the Buitdi t Department Existing Proposed Required by Zoning Lot size 42' x 109' = 4578 s.f. shed: 12' x 8' = 96 s.f. Frontage N/A N/A N/A Front: 36.6 feet 97 feet Setbacks: Side: 6.3 feet (L) 13.5 feet(R) 8 feet(R) Rear: - 31.5 feet 4 feet Height 2 stories 11 feet % Open space: Lot sze(457&)-Bonding(24 x (Lot area minus bldg and 40'=960')-driveway(13'x 73'= 2572 sf.156.2%ope open= 950')=2668sf.158.2%open 2572 s.fi 562%open paved perking) 10.Certification: I hereby certify that the information contained herein i- rue and accurate to the best of my knowledge. DATE:09106116 APPLICANT'S SIGNATURE _........ — r NOTE; Issuance of a permit does not relieve an applicant's burden to comply with all zoning requirements and obtain all required permits from the Conservation Commission, Department of Public Works and other applicable permit granting authorities SIMPLE SHED + 20 1/T Cut rafters Sheathing, 1x6 fascia from 102x6s Dnp cap Flashing _Asphalt shingles 21R 1x2 -=-__111811 5 L over building paper 1x8 fascia ` I k 1 RaftCr Sheathing 4 118 ktr T'11-1)16" Soffit vent-- '-.... "'.�„r Budding paper 31Y2 7 1” flashing \ L. ^ r RAFTER DETAIL .. Dip cap ._ x4 h'm i Nailer —' a 1°76 a 7- )'3/4"quarter round /. -Stdmg- p R Siding _window insert \-Soffit vent ;` —Siding FRONT DETAIL REAR DETAIL CORNER DETAIL __Floor joist 1/2 plywood sheathing(typical) Double 278 Double 2x5 2x6 rafters 2x4 blocking 916E DETAIL header header 16"00 r `,,--_ — I I Front wall, -- - ' • 10'7-1/4"high x 12 wide F;8172 Zflashng AIL a ]'&12"hrghxl2 wide 1/4 1 7 LILA , morn�sed o I 26 r 6-516 8-314 . - i puha Mk. 412 Suds r X37-314" o - 37314 11 i / t I I 1 ii— I I 1 5185H-11 (typical) _ i ply pressure-Treated plywood 2x6 pressure-treatedjoists 16"0C Concrete blocks set on 6"of grave `~"7 8'x 12 overall ._ .GprT::. B_ LD,N3 LOCAT :ON 0 iRAC` S N0/I CU ,Ah TEED NOTE: PROPERTY LINES SHOWN ARE APPROXIMATE, A FULL FIELD SURVEY IS REQUIRED 42 $ REFERENCE PLAN: TO ACCURATELY DETERMINE THEIR LOCATION. BOOK 11791, PLAN BK. 235, PG. 101 PAGE 164 NOTE: ri SUBJECT TO EASEMENTS AND — RIGHTS OF WAYS OF RECORD. o f+ FF Arcxi,T,.o to eage o. NOTE: saved arweway SUBJECT TO EASEMENT AND ENCROACHMENT AGREEMENT RECORDED IN BOOK 6888, PAGE 286. 42'± BRIGHT AVENUE TO: RESIDENTIAL MORTGAGE SERVICES & CONNECTICUT ATTORNEYS TITLE INSURANCE COMPANY TO THE BEST OF MY INFORMATION, KNOWLEDGE AND BELIEF I HEREBY REPORT THAT I HAVE EXAMINED THE PREMISES AND BASED ON EXISTING MONUMENTATION ALL VISIBLE EASEMENTS, ENCROACHMENTS AND BUILDINGS ARE LOCATED ON THE GROUND AS SHOWN AND THAT THE BUILDINGS ARE ENTIRELY WITHIN THE LOT LINES, EXCEPT AS NOTED. I FURTHER REPORT THAT THE PROPERTY IS NOT LOCATED WITHIN A FLOOD PRONE AREA AS SHOWN ON FEDERAL FLOOD INSURANCE MAPS FOR COMMUNITY #250167 —NOTE— SURVEYOR: Gkh1,tk'Q ?. h n THIS PLAT FOR MORTGAGE LOAN PURPOSES ONLY AND DOES NOT CONSTITUTE A PROPERTY SURVEY —MORTGAGE LOAN INSPECTION PLAT— v.‘"?. RANDALL NORTHAMPTON, MASSACHUSETTS 11 cs E �1 PREPARED FOR IZER NI MARK PACHUCKI & WINSLOW CARROLL X35032 SCALE: i 30' FEBRUARY 16, 2016 °� s °,, H ROI D L. AATON AND ASSOCIATES, INC. REG _ EKED RP FESSIONAL LAND SURVEYORS 255 RUSSELL STREET — HADLEY — MASS:.CHUSE—TL ., - -47 ' + 4' a i tyt 2cI Stied 1 8, BOOK 117431 , PAGE 1641 r - ♦ ,s r4 O O co #1 o co aPF ‘16,H- GE I / /I 42 ' ± 1 BRIGHT AVENUE