Loading...
30A-027 (3) 22 LEXINGTON AVE BP-2017-0237 GIS#: COMMONWEALTH OF MASSACHUSETTS (vtao-Block:30A-027 CITY OF NORTHAMPTON Lot:-OW Permit: Building Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2017-0237 Project# JS-2017-000396 Est. Cost: $21000-00 Fee: 575.00 PERMISSION IS HEREBY GRANTED TO: (;oust Class: Contractor: License: Use Group: NORTHEAST SOLAR DESIGN ASSOCIATES LLG 106113 Lot Size(sq. ft.): 20342,52 Owner: aELUZO ASHLEY N&SIMON HILDT Zoning:URB(l001 Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC AT: 22 LEXINGTON AVE Applicant Address: Phone: Insurance: 136 ELM ST (4131247-6045-0 HATFIELDMAO1038 ISSUED ON:8125/2016 0:00:00 TO PERFORM THE FOLLOWING WORK: Roof mounted PV solar 12 panels at 345w = 4.14kW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signature: FeeTvpe: Date Paid: Amount: Building 8/25/2016 0:00:00 575.00 212 Main Street, Phone(413)5871240, Fax: (4 13)587-1272 Louis Hasbrouck-Building Commissioner 4. . --- Department use only City of Northampton Status of Permit: 3 ' 2 2016 Building Department Curb Cut/Ddveway Permit 212 Main Street Sewer/Septic Availability Room 100 WaterlWell Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans ther OSHcity APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property AtldreggThis section to be completed by office Map Lot Unit 22 Lexington Ave, Northampton Ma 01062 Zone Overlay District Elm St.District CB District 7 SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Simon Hildt 22 Lexington Ave, Northampton Ma 01062 Name{Pry Gwent Mailing Andress. 413-345-1281 Telephone Signature _ 2.2 Authorized Agent: Northeast Solar 136 Elm St, Hatfield Ma 01038 Name(Print) Current Mailing Address: _ 913-297-6095 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a)Building Permit fee 2. Electrical (b)Estimated Total Cost of Construction from(S) _ 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5, Fire Protection 6. Total-T-0 +2+3+4+5) 21,000 Check Number r' i(S This Section For Official Use Only Date Building Permit Number: iiiii, Issued: /, - . %V - Signature: �r O — 5s I Building Commissioner/Inspector of Buildings Date Section A. ZONING All Information Must Be Completed.Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be Filled in by Building Department Lot Size Frontage Setbacks Front Side L:'. R. L. ,'.. Rear I Building Height v Sid@ Square Footage % Open Space Footage Met area miens bids&paved _ parkin¢) ....... of Parking Spaces Fill: lvolutrnn&Location) A. Has a Special Permit/Variance/Finding ever been issued far/on the site? NO 0 DONT KNOW ® YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW Q YES Q IF YES: enter Book Page and/or Document # B. Does the site contain a brook, body of water or wetlands? NO © DONT KNOW Q YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained Q , Date issued: C. Do any signs exist on the property? YES Q NO a IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO Q IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NC) IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition El I Replacement Windows Alteration(s) ❑ Roofing 7 Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks Iq Siding [O] (Other[X Brief Description of Proposed ! i /_/// Ia,lyO3(! ,SN, Work: Install 12 Solar Electric panels on roof !+ K V" Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes _No Plans Attached Roll -Sheet Oa.If New house and or addition to existing housing, complete the following: A Use of building:One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves_ Number of each _ g. Energy Conservation Compliance. Masseheck Energy Compliance form attached? h. Type of construction is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No I, Septic Tank City Sewer — Private well _ City water Supply SECTION Ta•OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Simon Hildt ,as Owner of the subject property Northeast Solar hereby authorize to act to act on my behalf,in an alive to work authorized by this building permit application. eC/7 -QOM_ Signature of Owner Date Northeast Solar I, as Owner/Authorized ... Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Ann Bronner Print Name —...... ..—......._.. 6/6/2016 Signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 0.1 Licensed Construction Supervisor: Not Applicable ❑ Phillip Baunsgard CS106113 Name of License Holder: License Number 41 Heath Rd Colrain, Ma 01390 6/7/17 A.. - Expiration Date • ��i// 413-247-6045 . .r .n _ - < e *Owns 9,Registered Home Improvement Contractor: Not Applicable ❑ Northeast Solar. 169641 Company Name Registration Number 136 Elm St. Hatfield, Ma 01035 7(14/17 Address Expiration Date Telephone 413-24 7-6 04 5 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application.Failure to provide this affidavit wilt result in the denial of the issuance of the building permit._ Signed Affidavit Attached Yes X3 No C 11. - Home Owner Exemption The current exemption for"homeowners'was extended to include Owner-occupied Dwellings of one(I) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner gets as supervisor.CMR 780, Sixth Edition Section 108.35.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,oris intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two-Fear period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Lows Annotated,you may be liable for persons) you hire to perform work for you under this permit. The undersigned"homeowner`certifies and assumes responsibility for compliance with the State Building Code.City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Lays Annotated, Homeowner Signature. Vreeland Design Associates An integrative approach to design engineering and site planning Date: August 18, 2016 'Po: Ann Bronner NorthEast Solar 136 Elm Street Hatfield,MA 01038 From: David Vreeland,P.E. Vreeland Design Associates Re: Simon Hi1dt,22 Lexington Ave,Florence, MA:Structural assessment of existing garage roof to support proposed solar array. I have investigated the existing roof framing and reviewed the plans,dated 5/10/16, for the south roof extension for the 14'x 22' garage for the proposed PV solar pane! installation.The existing rafters are 2x6 installed at 16" on-center, spanning 7'. The south roof extension is framed with 2x6 rafters at 16"on-center, supported on the south wall and on 2-2x6 eave beam 6'-6"off the south wall.The 2-2x6 eave beam is supported by 4x4 posts installed at 6'-9" on-center. The roof and roof extension have a roof slope of 5/12_The roofing is asphalt shingles. 12 solar panels are proposed on the south roof. I have reviewed the mounting details for the proposed array. Based on my calculations and a PV solar panel unit weight of 42±lbs,with the attachment points of the array placed at a maximum of 4' on center and staggered to minimize the load to any one rafter,the existing roof framing is adequate to support the proposed PV solar array and the snow and wind load requirements of the current MA State Building Code. Please contact me if you have any questions or need additional information. Sincerely, xZN OF Mrs p o`er DAVID A. 6G 'i\ (L 1 I ) 4# EP YREEtAND To David Vreeland, PE m o,aunt o Vreeland Design Associates sOt eP K�� A4stettm 116 Riva Road, Leyden, MA 01337 Phone: (413)624-0126 Email: dvreeland@verizan.net Fax: (413) 624-3282 i :qif i „ iii'44:41"tcr Shy � yy y .4l I *1 -ba;_ ,J{ k3 ) 44% :nil`. SunPower® X21-345-C-AC Residential AC Module Series Power Data SPR421-34S-C- C SPR-X21 335{AC _ w _ h yr v r finnnl - Iwryia LLne.e lrl r . i Fr.r1C (if =nn< nommh P IL P 21 ,� 2iv nnarg n. � i (P' 1 0 _ P • r h,. uia^ir,t Ham- it .i . 1 n0 < 'I_- c Sir Iii�n�n Lege3crm J ma.ingni 94499 fieri[ 1;$I^s -a) 00 04 Pahang Hag I aurae°J 13a 4 r) Ate Egg han-fh4 IP .r arJ '$3 bdru9v Warranties and Certifications �0 ,rrr r r Hz - 9r<r rhC.SHe en nli. 09 E40 1,14 reVI"I Or .1, , 1 1 i Cur'40 'Eh” NE' I „.4 L 9 ni ✓m e, AC I l.. r 11 n ,on f C 1 N 1 4 Ir r 4 1 IEEE 1tra 12-hang(phase I r:od le ii'a i(a'+i 4 I t PA 2P A F IEr 2 2J( 1 1011rr ciel I,L l ip- [I I Iran lr.l ui i r 490114 a'Ur•.= i rnnuti•, (En A F : i e'r in 1n.l:ma' Ha, ani rn To if 122 r ,0`CI , ,ni�f eH.'" vod 52 Fr 3414 PE 305<rma ^rr r R hark Enna 12E,[9 haN.fA Eh' (6,grE4 g aggeter ha lel 'nit Ofl EnE0p PIC.less 1 it thi p.ai.YW * _ a ` 143 inJ �oe !$ SUNPOWEW �j ti , ,ar,H''kM✓t t 44r' jxwf'rs m.t,n'.3a+�g,Q' „,' .'.'paa a•„rt 2z° :451ea�i-4S`l°�.'t_ t xri,�V "tiu.`7 Mt ,ve xT r 9; • lik• l.' IC r - �l .$f t'xtr -:. electtL ... r:,1.4.1.....„,;;;,..„..4, �; }teMain house aurty ` g ' } sre - 1F .l S '*. 44/ .. in '••• -",a1' t1/4;3.1!.:: (1.*-'''‘' •rt ^ .:: L " kivye4q basem t s 5 „ . ', u YI4J .;�r " x v n *volt ' ? JJC ir " a • rt • • 1. nsS}.Y:Yf • ._ -:Vr*d� ^ 2. �i 'r� l- ' 7,4 w4Cr ' x .., t) ? 2 ( tx , il ] 4•111;4;...-';:i''' s mo ,> St Fb ?'hNT. 44.4t.•;;; t '3 •-e.‘"•-';', e. yR :i a\d, yW - i: s. - • r�` a• y.„fit V ltrhsame v lYF f M {irtv .r � vro ''• r 'l ' t t at1, i a v A C tA- x ••,:cit:• 4�i. It7. , ;46.4: 4”•'• 'l.*:-..,..6,N.:..."44'..F §. nK .,,i` NS4 . ✓ mo ° • - 41C...4i • ii aS.- ---- ...- - I 1 ' • ifr .lY _ . , � fitly '4 ` w \, :;-40 � 5�Y . .c'r' k1 � N � [ ,- ` 4.71,,V.:•-• ` F ? 44Gnt9q • ."y � -. ',, -, n, ', „j "rb. p , "� F ' art re a.a } ! ..40: J ." . , , ,;---7'4. 4 _' r c rc -4 - *fe ,rK { � ,-c t.' +.. y j, "T.' -a . x' xj''* w ,„'• -1. .:.%:",.: r . W IS ' ' AT $ 1 n + °xtvytibv4LLt h . . 'wy —Ro 2 • .. 1 ... iQ y !'! Y % v *74t. i:-7. Stq ' . d • • • it T '"" ye % t t - ?� auR: .o-t ,572m}tr- . .. ♦ 114^ t :j• :::' rt ;yeP\ y _. 'S .3sswa4 """orrr . \ /E... a • , \ ye.f wrL S sr „ tt4zx t ci; IM I, "t ' ”- k 1 �` x tiwi fir t L � 4--'147.•.'-",::••-•":;.<.".. ..!;..";i-,1 . b E ' t - ': \� . 4, yi ^ I I`44 I3 't4 .y,} } F2- ; T -0-tit-t4 472 , 4. '' r1rN �. iy`^ rsY tL ; t a- 1 , rr" , �o � \ ; v \"4.-...-4,,,,,-i ! :5 .?xriy ~aa . tiYyxy- '' �v ". r ; n aA hy a4-,,: s' .+ +}�f•F .4-1r;t :170.;' :r!:1 ; * �v4v i '''—'4" 1qv +, ry,.i sh x.- ° k F ' ° f . Nt k4i Px i ^T • #. *..„3. r..c -t A e NI9 rEv t m 6„b , Y (•„ o s - ^"'w .�2.sy <s : z. .,, w�W sj `w •*{..., ...... ..:1-..:T4,... -•:,. rt "M]1 y a A;4ti 1ika i-r �' r 1 ' 4 ' r • '' •''RTh rRi� . cy. k r . � "� mPonr 1:VI•1 . 5 • t � - 2:. A. odtienia ` t .i 72�'r £ . ' x -r� .a, =� GiiY of Depart" Jw + . 'v i #"j . - . -r$\B � f : e ,, x { ...;4 x : `s %\ • vadtn9avetQtanStrP� ortz NAP, .'n; t 1 ' '!rcc : r;:> atts4tn • Nodx •t . "' aL.5 � . t *! . - /c•4•:.=, ' r �j 7 Oitfie�C5 j rF4 J -- E 1 /. -� �s gehzo< ..r AshleyAve 9t � 22LeXinMa 0106 Northampton, - } SunPower®' InvisiMountTM I Residential Mounting System ',aoo l i l ,-i IrwvoisiMounComponent Images t m.. ,,,ii ....„ .., _ +� ;r.p „,,,. .,,,Th at nil al I! 7- .... ....„ ,,::,.... , . ..„,, 4„,,,, .., InvlsiMount Component Details InvlsiMount Operating Conditions ,un 1"Co oo^ G'rc LG Fl l .laooal :e�pe� ._max 'l „rls InvisiMount Warranties And Certifications c l Roof Attachment Hardware Supported by - InvlslMountSystemDesignTool • r _ ., t ,, ., v _ 41i ,r le:, . l ni SUNPOWER` tt..il.l_ lute _: a , :l] — .11i _a. —a it u. Northeast 1 1 it _ _ _ 11411w t V LI 1. F 11J I .....1 1 tt7J Typical feet placement w/ 16" o.c. rafter spacing, i_ ., IA IlD 1 .f. .. -111 1 Typical feet placement w/ 24" o.c. rafter spacing "41"; ; ': 4. th ;1 II lil I IIIIt 1III 1 I III . a. _,I.' t !'I I'll' ' L^'I vt-. 1 I 1 . .. .. .. .. .I .