Loading...
31A-069 (7) 34 -06' 9 rc2,a rvie, Al Spectrum Services ices 43 :gh; tats Road,Sinn MA 01598 69 rentworLn Road.Revert...184k Uric Phone: 538-865A525• iHd.: 5388865-5525 8n 6 c13P'. Hmai::z ts,cc@chaacr.net July 24, 2016 Report For: Wm J Turomsha Design and Construction Attn.: Bill PO Box 141 Leeds, MA 01053 Project: Residence 206 Elm Street Northampton, MA Scope: Al Spectrum Services was contracted to perform a limited asbestos inspection at the above entitled property. The purpose of the inspection was to identify select suspect materials in terms of presence of asbestos so they can be removed prior to renovations. The scope of work was defined by the General Contractor. Date of Inspection: July 19, 20.16 Methodology: Industrial.hygiene services were conducted by Robert F Gravallese, a Professional Industrial Hygienist and Massachusetts licensed asbestos inspector. Those materials suspected to be asbestos containing were sampled, containerized, labeled and transferred to a Massachusetts licensed laboratory for analysis by Polarized Light Microscopy. Sample locations were selected, whenever possible, on the basis of being able to obtain all strafes or multi layer or potentially multi layer materials. When this was not a needed consideration samples were collected at random locations with the aide of the computer application: Geomidpoint.com/random. The program is useful when the area is a regular geometric object such as a square or rectangle. For the purposes of this report the front(street side) of the building will be considered facing North. Analysis: Analysis of the bulk samples were performed by EPA Method 600/R-93/116, July 1993 (Polarized Light Microscopy). All samples were analyzed by Asbestos ID Lab. Woburn, MA. A Mass. DLS licensed and NVLAP accredited laboratory. (Mass#AA 0000216). • Results: ASBESTOS BULK SAMPLING DATA Location Material _ _ ' Composition l Exterior —_- -_ -- -- - ,Exterior, East Transite Shingle Asbestos 15 Non Fibrous 85 Exterior, West Transite Shingle • Asbestos II 20 Non Fibrous 80 T- Trace -Chrysotile is a common form of asbestos. Findings. There is an asbestos containing material on the building in the form of Transite Shingles. It is suggested the material be removed by a Mass. DLS licensed asbestos abatement contractor. All other suspect materials were negative for the presence of asbestos. SUMMARY TABLE (Asbestos Containing Materials) Location Material Condition 1 Quantity Exterior Transite Shingles Not 2600 SF F Damaged Recommendations: The asbestos containing materials should be removed by a Mass. DLS licensed asbestos abatement contractor. There is a ten day notification period which must lapse prior to the start of abatement work. Robert F. Gravallese Al#60817 c: file E s Asbestos identification Laboratory Batch; 14949 S — O 165 New Boston St., Ste 271 te e Woburn, MA 01801 \ r� r-� n v KA: w 781-932-9600 to vvex www.asoestcsd ntficalioniab.com e Friar mikemann'ng@asb ider.:ificationlab.com p1CATf0 Lab Code: 200919-0 July 22,2016 Bob Gravallese Project Number: A-1 Spectrum Services Project Name:206 Elm 43 Eight Lots Road Sutton, MA 01590 Date Sampled: 2016-07-19 Work Received: 2016-07-21 Analysis Method: BULK PLM ANALYSIS EPA/600/,R-93/116 Dear Bob Gravallese, Asbestos Identification Laboratory has completed the analysys of the samples from your office for the above referenced project The information and analysis contained in this report have been generated using the EPA /600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. Materials or products that contain more than 1% of any kind or combination of asbestos are considered an asbestos containing building material as determined by the EPA. This Polarized Light Microscope (PLM) technique may be performed either by visual estimation or point counting. Point counting provides a determination of the area percentage of asbestos in a sample. If the asbestos is estimated to be less than 10% by visual estimation of friable material, the determination may be repeated using the point counting technique. The results of the point counting supersede visual PLM results. Results in this report only relate to the items tested. This report may not be used by the customer to claim product endorsement by NVLAP or any other U.S. Government Agency. Laboratory results represent the analysis of samples as submitted by the customer. Information regarding sample location, description, area, volume, etc., was provided by the customer. Asbestos Identification Laboratory is not responsible for sample collection activities or analytical method limitations. Unless notified in writing to return samples, Asbestos Identification Laboratory discards customer samples after 30 days. This report shall not be reproduced, except in full, without the written consent of Asbestos Identification Laboratory. • NVLAP Lab Code:200919-0 • Massachusetts Certification License:AA000208 • State of Connecticut, Department of Public Health Approved Environmental Laboratory Registration Number:PH-0142 • State of Maine,Department of Environmental Protection Asbestos Analytical Laboratory License Number:LB-0078(Bulk)LA-0087(A r) • State of Rhode Island and Providence Plantations Department o'Health Certification:AAL-121 Thank you Bob Gravallese for your business. Michael Manning Owner/Director July 22,2016 Bob Gravallese Project Number: A-1 Spectrum Services Project Name:206 Elm 43 Eight Lots Road Sutton, MA 01590 Date Sampled: 2016-07-19 Work Received: 2016-07-21 Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116 - - „„o_. ...,u. _.. FleldID Material Location Color Non-Asbestos % Asbestos % Lablo - ,_ .. .,.. _._- .o. .-. 206E 1 Trans gray Non-Fibrous s 85 Detected Chrysotile 15 164882 206E 2 Trans gray Non-Fibrous E0 Detected Chrysotile 20 164883 Friday 22 July 2016e�,? End of Report Page 1 of 1 Analyzed by: /` "' 7 Batch: 14949