31A-143 (4) File#SM-2015-0014ry ''
APPLICANT/CONTACT PERSON MORANETA0
ADDRESS/PHONE 139 EAST MEADOW ST (413)592-0031 O
AfICA
PROPERTYLOCATIONR L1430 FZONESAVE
MAP 3IA PARCEL 143 001 ZONE URB(100)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out (1%.5-3 115.`2S
Fee Paid
Tvpeof Construction- INSTALL 3 FLRS DUCTWORK
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/Statement or License
3 sets of Plans/Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFORMATION PRESENTED:
_Approved __Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER : §
Intermediate Project: Site Plan AND/OR Special Permit with Site Plan
Major Project: Site Plan AND/OR _Special Permit with Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance* _
Received& Recorded at Registry of Deeds Proof Enclosed_
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission Permit DPW Storm Water Management
Signature of Building Official Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission, Department
of public works and other applicable permit granting authorities.
* Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of
Planning&Development for more information.
ECE
Q 2 a 2014 J7�
OCTCommonwealth of Massachusetts
a Peke City Of Northampton
nec_ Date: /0/4,-//// Sheet Metal Permit Permit# c45--/9
Estimated Job Cost: $ 26 , coo.o Permit Fee: $PSi --
Plans Submitted: YES NO Plans Reviewed: YES NO
Business License# /3V Applicant License# /879
Business Information: Property Owner/Job Location Information:
Name: ird rtir sa' ±r.n crud. Name: 'tic Se
Street: 12 x C.xar mt.rw.,.s Street:_ay toec„_ _-0;'E,
CityITown: Cr is at dart City/Town: Noeter, 7 rig/ ............
Telephone: yi y _ s—!2 -00 3 iTelephone:
Photo 1.D. required/Copy of Photo I.D. attached: YES ✓ NO_
,,� Staff
Yt
lnifinl
J- Mi-unrestricted license
.1-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less
Residential: 1-2 family ,..-i Multi-family_ Condo/Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other
Square Footage:-under 10,000 sq. ft. „✓ over 10,000 sq. ft. Number of Stories: 3
Sheet metal work to be completed: New Work: ✓ Renovation:
HVAC -�' Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/ Vents Air Balancing
Provide detailed description of work to be done:
/Alt 1-00,C. v✓t rwOt.t SC2vi.Ve 3r.-e.e.J
Fees with Budding Permit:$25.00 Residential,$50.00 Commercial.Fees for jobs without a Budding Permit$6.00 per$1000
Minimum fees blobs without Building Permit$50.00 Residential,$100.00 Commercial
INSURANCE COVERAGE:
I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Yes i2rido 0
If you have checked Yes,indicate the type of coverage by checking the appropriate box below:
A liability insurance policy Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER:i am aware that the licensee does not have the Insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application wnivee this requirement.
Check One Only
Owner ❑ Agent ❑
Signature of Owner or Owner's Agent
By checking this box3,'Ihereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and Installations performed under the permit Issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation:YES NO
Meow-ow tnapertinne
Date - Comments
Final tncpertipp
Date Comment%
Type of License:... - ......-
By 0 Master
Title 0 Master-Restricted
Ciy1Fown ❑Journeyperson
Signature of Licensee
Permiin ❑JourneypersoreRestricted /try
$ License Number:
Check at www maga geluirlpt
Inspector Signature of Permit Approval
g Load Short Form Job: 13A
wri ht5pft Date: Oct 17,2014
Entire House By: RONG
MORAN SHEET METAL
139 EAST MEADOW ST,CHICOPEE,MA 01613
Project Information
For 'TIRK-ERICKSON HOUSE"-FIRST FLOOR
34 FORBES AVE,NORTHAMPTON,MA
Design information
Htg Cig Infiltration
Outside db(°F) 0 93 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD CF) 70 18 Fireplaces 0
Daily range - M
Inside humidity(%) 50 50
• Moisture difference(grab) 51 14
HEATING EQUIPMENT COOLING EQUIPMENT
Make ADP Make NORDYNE
Trade "B"SERIES HYDRO-AIR Trade GIBSON J5450 SERIES
Model BCRMA4624S3N3 Cond JS4BD-018K6
AHRI ref Coil BCRMA4624S3N3
AHRI ref 4862202
Efficiency 84 AFUE Efficiency 11.5 EER, 13 SEER
Heating input 33820 MBtuh Sensible cooling 12600 Btuh
Heating output 28184 Btuh Latent cooling 5400 Btuh
Temperature rise 44 °F Total cooling 18000 Btuh
Actual air flow 588 cfm Actual air flow 588 cfm
Air flow factor 0.026 cfrnlBtuh Air flow factor • 0.043 cfm/Btuh
Static pressure 0.10 in H2O Static pressure 0.10 in H2O
Space thermostat Load sensible heat ratio 0.91
ROOM NAME Area Htg load CIg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
ENTRY/STAIR 146 5766 2662 148 115
5A1H1 16 967 401 25 17
UVING ROOM 296 5177 3834 133 166
KITCHEN 204 4799 3041 123 131
PANTRY/CLOSET 38 1488 406 38 18
DINING ROOM 150 4668 3272 120 141
Entire House d 851 22865 13616 588 588
Other equip loads 0 0
Equip.@ 0.98 RSM 13344
Latent cooling 1399
TOTALS 851 22865 ' 14742 588 588
Boldrralic values have OMR manually avarHdGbn
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-. -4-wrightsott RgM-SuIee Universal x01212.101 R3U1314e 20140a-20r pagai
age i
/1CCA ...6eI11ng5Vim GagnelMy CoartreMsrWrlgM1iSGR FNACUAORSNE13AruD Celce M. Front comyaces'. Paget
W ri9htsofY Load Short Form JO13B
Date: Oct 17,2014
Entire House By: RON O
MORAN SHEET METAL
139 EAST MEADOW ST,CHICOPEE,MA 01013
Project Information
For: "TIRK-ERICKSON HOUSE'-SECOND FLOOR
34 FORBES AVE, NORTHAMPTON, MA
Design Information
Htg Clg Infiltration
Outside db(°F) 0 93 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TO (°F) 70 18 Fireplaces 0
Daily range - M
Inside humidity(%) 50 50
Moisture difference(grab) 51 14
HEATING EQUIPMENT COOLING EQUIPMENT
Make ADP Make NORDYNE
Trade "B" SERIES HYDRO-AIR Trade GIBSON JS4BD SERIES
Model BCRMA4624S3N3 Cond JS4BD-018KB
AHRI ref Coil BCRMA4624S3N3
AHRI ref 5055016
Efficiency 84 AFUE Efficiency 11.0 EER, 13 SEER
Heating input 33820 MBluh Sensible cooling 12180 Btuh
Heating output 28184 Btuh Latent cooling 5220 Btuh
Temperature rise 44 °F Total cooling 17400 Btuh
Actual air flow 588 cfm Actual air flow 588 cfm
Air flow factor 0.037 cfm/Bluh Air flow factor 0.049 cfm/Btuh
Static pressure 0.10 in H2O Static pressure 0.10 in H2.0
Space Thermostat Load sensible heat ratio 0.90
ROOM NAME Area Htg load Clg load Htg AW Clg AVF
(re) (Btuh) (Btuh) (cfm) (cfm)
MASTER BED ROOM 194 4243 3576 157 177
BATH 2 95 2774 1427 103 71
CLOSET 41 596 344 22 17
UPR HALL/STAIR 98 2015 1762 75 87
LAUNDRY 63 916 1104 34 55
BED ROOM 2 125 2988 2142 111 106
BATH 3 81 2343 1535 87 76
Entire House d 697 15874 11889 588 588
Other equip loads 0 0
Equip. Q 0.98 RSM 11652
Latent cooling 1269
TOTALS 697 15874 12921 588 588
adNaalic woes nay,been manually evimadrn
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
7014-0c,2018:41:35
1 -Pk Wrightsoft Rmhe5HIMP uruwenal:tot 212,1,01 RSu13148 =ogee
ADCA ...SeaIngst¢on Oagnewy DocumemfWrigF.vot 1NACWORSHE13B.nip Calc=MJ8 From Dow iacm: Page 1
Load Short Form Job: 13C
4. Wrightsoft Date: Gan,2014
Entire House By: RON G
MORAN SHEET METAL
139 EASTMEAOOW ST.CHICOPEE MA01013
Project Information
For: 'TIRK-ERICKSON HOUSE-ATTIC FLOOR
34 FORBES AVE NORTHAMPTON,MA
Design Information
Htg Clg Infiltration
Outside db(°F) 0 99 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TO(°F) 70 18 Fireplaces 0
Daily range M
Inside humidity(%) 50 50
Moisture difference(grllb) 51 14
HEATING EQUIPMENT COOLING EQUIPMENT
Make ADP Make NORDYNE
Trade "B"SERIES HYDRO-AIR Trade GIBSON JS4BD SERIES
Model BCRMA4624S3N3 Cond JS4BD-018KB
AHRI ret Coil BCRMA4624S3N3
AHRI ref 5347708
Efficiency 84 AFUE Efficiency 9.5 EER. 13 SEER
Heating input 33820 MBtuh Sensible cooling 11200 Btuh
Heating output 28184 Btuh Latent cooling 4800 Btuh
Temperature rise 44 °F Total coding 16000 Btuh
Actual air flow 588 cfm Actual air flow 588 cfm
Air flow factor 0.040 cfm/Btuh Air flow factor 0.063 cfnVBtuh
Static pressure 0.10 in H2O Static pressure 0.10 in H2O
Space thermostat Load sensible heat ratio 091
ROOM NAME Area Htg load Cig bad Htg AVF Ctg AVF
(f?) (Btuh) (Btuh) (cfm) (cfm)
MAIN AREA 396 12683 7767 508 485
BATH 4 49 2006 1640 80 103
Entire House d 445 14689 9407 588 688
Other equip loads 0 0
Equip, @ 0.98 RSM 9219
Latent cooling 969
TOTALS 445 14689 10188 588 588
Bok/itaik values neve eon manually ovanldbn
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Oct-2019,52:25
a wrightsorr RIga4Sul0&Universal 201212.1 Al R5U13148 Page l
MCA -SettIgs1Ron Gagnewy Documentslwriightoft HVAQMORSHE13C.rup Cabs MJB Front Door races: Pagel