Loading...
31A-143 (4) File#SM-2015-0014ry '' APPLICANT/CONTACT PERSON MORANETA0 ADDRESS/PHONE 139 EAST MEADOW ST (413)592-0031 O AfICA PROPERTYLOCATIONR L1430 FZONESAVE MAP 3IA PARCEL 143 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out (1%.5-3 115.`2S Fee Paid Tvpeof Construction- INSTALL 3 FLRS DUCTWORK New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: _Approved __Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER : § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR _Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* _ Received& Recorded at Registry of Deeds Proof Enclosed_ Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning&Development for more information. ECE Q 2 a 2014 J7� OCTCommonwealth of Massachusetts a Peke City Of Northampton nec_ Date: /0/4,-//// Sheet Metal Permit Permit# c45--/9 Estimated Job Cost: $ 26 , coo.o Permit Fee: $PSi -- Plans Submitted: YES NO Plans Reviewed: YES NO Business License# /3V Applicant License# /879 Business Information: Property Owner/Job Location Information: Name: ird rtir sa' ±r.n crud. Name: 'tic Se Street: 12 x C.xar mt.rw.,.s Street:_ay toec„_ _-0;'E, CityITown: Cr is at dart City/Town: Noeter, 7 rig/ ............ Telephone: yi y _ s—!2 -00 3 iTelephone: Photo 1.D. required/Copy of Photo I.D. attached: YES ✓ NO_ ,,� Staff Yt lnifinl J- Mi-unrestricted license .1-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less Residential: 1-2 family ,..-i Multi-family_ Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage:-under 10,000 sq. ft. „✓ over 10,000 sq. ft. Number of Stories: 3 Sheet metal work to be completed: New Work: ✓ Renovation: HVAC -�' Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/ Vents Air Balancing Provide detailed description of work to be done: /Alt 1-00,C. v✓t rwOt.t SC2vi.Ve 3r.-e.e.J Fees with Budding Permit:$25.00 Residential,$50.00 Commercial.Fees for jobs without a Budding Permit$6.00 per$1000 Minimum fees blobs without Building Permit$50.00 Residential,$100.00 Commercial INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Yes i2rido 0 If you have checked Yes,indicate the type of coverage by checking the appropriate box below: A liability insurance policy Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER:i am aware that the licensee does not have the Insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application wnivee this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box3,'Ihereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and Installations performed under the permit Issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation:YES NO Meow-ow tnapertinne Date - Comments Final tncpertipp Date Comment% Type of License:... - ......- By 0 Master Title 0 Master-Restricted Ciy1Fown ❑Journeyperson Signature of Licensee Permiin ❑JourneypersoreRestricted /try $ License Number: Check at www maga geluirlpt Inspector Signature of Permit Approval g Load Short Form Job: 13A wri ht5pft Date: Oct 17,2014 Entire House By: RONG MORAN SHEET METAL 139 EAST MEADOW ST,CHICOPEE,MA 01613 Project Information For 'TIRK-ERICKSON HOUSE"-FIRST FLOOR 34 FORBES AVE,NORTHAMPTON,MA Design information Htg Cig Infiltration Outside db(°F) 0 93 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD CF) 70 18 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 • Moisture difference(grab) 51 14 HEATING EQUIPMENT COOLING EQUIPMENT Make ADP Make NORDYNE Trade "B"SERIES HYDRO-AIR Trade GIBSON J5450 SERIES Model BCRMA4624S3N3 Cond JS4BD-018K6 AHRI ref Coil BCRMA4624S3N3 AHRI ref 4862202 Efficiency 84 AFUE Efficiency 11.5 EER, 13 SEER Heating input 33820 MBtuh Sensible cooling 12600 Btuh Heating output 28184 Btuh Latent cooling 5400 Btuh Temperature rise 44 °F Total cooling 18000 Btuh Actual air flow 588 cfm Actual air flow 588 cfm Air flow factor 0.026 cfrnlBtuh Air flow factor • 0.043 cfm/Btuh Static pressure 0.10 in H2O Static pressure 0.10 in H2O Space thermostat Load sensible heat ratio 0.91 ROOM NAME Area Htg load CIg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) ENTRY/STAIR 146 5766 2662 148 115 5A1H1 16 967 401 25 17 UVING ROOM 296 5177 3834 133 166 KITCHEN 204 4799 3041 123 131 PANTRY/CLOSET 38 1488 406 38 18 DINING ROOM 150 4668 3272 120 141 Entire House d 851 22865 13616 588 588 Other equip loads 0 0 Equip.@ 0.98 RSM 13344 Latent cooling 1399 TOTALS 851 22865 ' 14742 588 588 Boldrralic values have OMR manually avarHdGbn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -. -4-wrightsott RgM-SuIee Universal x01212.101 R3U1314e 20140a-20r pagai age i /1CCA ...6eI11ng5Vim GagnelMy CoartreMsrWrlgM1iSGR FNACUAORSNE13AruD Celce M. Front comyaces'. Paget W ri9htsofY Load Short Form JO13B Date: Oct 17,2014 Entire House By: RON O MORAN SHEET METAL 139 EAST MEADOW ST,CHICOPEE,MA 01013 Project Information For: "TIRK-ERICKSON HOUSE'-SECOND FLOOR 34 FORBES AVE, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db(°F) 0 93 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TO (°F) 70 18 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(grab) 51 14 HEATING EQUIPMENT COOLING EQUIPMENT Make ADP Make NORDYNE Trade "B" SERIES HYDRO-AIR Trade GIBSON JS4BD SERIES Model BCRMA4624S3N3 Cond JS4BD-018KB AHRI ref Coil BCRMA4624S3N3 AHRI ref 5055016 Efficiency 84 AFUE Efficiency 11.0 EER, 13 SEER Heating input 33820 MBluh Sensible cooling 12180 Btuh Heating output 28184 Btuh Latent cooling 5220 Btuh Temperature rise 44 °F Total cooling 17400 Btuh Actual air flow 588 cfm Actual air flow 588 cfm Air flow factor 0.037 cfm/Bluh Air flow factor 0.049 cfm/Btuh Static pressure 0.10 in H2O Static pressure 0.10 in H2.0 Space Thermostat Load sensible heat ratio 0.90 ROOM NAME Area Htg load Clg load Htg AW Clg AVF (re) (Btuh) (Btuh) (cfm) (cfm) MASTER BED ROOM 194 4243 3576 157 177 BATH 2 95 2774 1427 103 71 CLOSET 41 596 344 22 17 UPR HALL/STAIR 98 2015 1762 75 87 LAUNDRY 63 916 1104 34 55 BED ROOM 2 125 2988 2142 111 106 BATH 3 81 2343 1535 87 76 Entire House d 697 15874 11889 588 588 Other equip loads 0 0 Equip. Q 0.98 RSM 11652 Latent cooling 1269 TOTALS 697 15874 12921 588 588 adNaalic woes nay,been manually evimadrn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 7014-0c,2018:41:35 1 -Pk Wrightsoft Rmhe5HIMP uruwenal:tot 212,1,01 RSu13148 =ogee ADCA ...SeaIngst¢on Oagnewy DocumemfWrigF.vot 1NACWORSHE13B.nip Calc=MJ8 From Dow iacm: Page 1 Load Short Form Job: 13C 4. Wrightsoft Date: Gan,2014 Entire House By: RON G MORAN SHEET METAL 139 EASTMEAOOW ST.CHICOPEE MA01013 Project Information For: 'TIRK-ERICKSON HOUSE-ATTIC FLOOR 34 FORBES AVE NORTHAMPTON,MA Design Information Htg Clg Infiltration Outside db(°F) 0 99 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TO(°F) 70 18 Fireplaces 0 Daily range M Inside humidity(%) 50 50 Moisture difference(grllb) 51 14 HEATING EQUIPMENT COOLING EQUIPMENT Make ADP Make NORDYNE Trade "B"SERIES HYDRO-AIR Trade GIBSON JS4BD SERIES Model BCRMA4624S3N3 Cond JS4BD-018KB AHRI ret Coil BCRMA4624S3N3 AHRI ref 5347708 Efficiency 84 AFUE Efficiency 9.5 EER. 13 SEER Heating input 33820 MBtuh Sensible cooling 11200 Btuh Heating output 28184 Btuh Latent cooling 4800 Btuh Temperature rise 44 °F Total coding 16000 Btuh Actual air flow 588 cfm Actual air flow 588 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.063 cfnVBtuh Static pressure 0.10 in H2O Static pressure 0.10 in H2O Space thermostat Load sensible heat ratio 091 ROOM NAME Area Htg load Cig bad Htg AVF Ctg AVF (f?) (Btuh) (Btuh) (cfm) (cfm) MAIN AREA 396 12683 7767 508 485 BATH 4 49 2006 1640 80 103 Entire House d 445 14689 9407 588 688 Other equip loads 0 0 Equip, @ 0.98 RSM 9219 Latent cooling 969 TOTALS 445 14689 10188 588 588 Bok/itaik values neve eon manually ovanldbn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Oct-2019,52:25 a wrightsorr RIga4Sul0&Universal 201212.1 Al R5U13148 Page l MCA -SettIgs1Ron Gagnewy Documentslwriightoft HVAQMORSHE13C.rup Cabs MJB Front Door races: Pagel