06-064 63 CHESTNUT AV EXT lot 22 BP-2016-1536
GIS a: COMMONWEALTH OF MASSACHUSETTS
Mao:Block: 06-064 CITY OF NORTHAMPTON
Lot:-000
Permit: Building
Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT
Permit it BP-2016-1536
Project# JS-2016-002617
Est.Cost: $16000.00
Fee: $75.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: SOLARCITY CORP 108706
Lot Size(sq. ft.): Owner: Joshua Birk
LlititagL Applicant: SOLARCITY CORP
AT: 63 CHESTNUT AV EXT lot 22
Applicant Address: Phone: Insurance:
604 SILVER ST (978) 215-2369 Q
AGAWAMMA01001 ISSUED ON:6/27/2016 0:00:00
TO PERFORM THE FOLLOWING WORK:Roof mounted PV solar 25 - 260 kW panels = 6.5
kW
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature: FeeTvpe:
Date Paid: Amount:
Building 6/27/2016 0:00:00 $75.00
212 Main Street, Phone(413)587-1240, Fax:(413)587-1272
Louis Hasbrouck-Building Commissioner
I • Department use only
or City of Northampton Stehle of Permit:
� .._.
•i � Building Department Curb Cut/Driveway Permit
212 Main Street serer/SeOCAvailability
Room 100 Wafer/WeR Availability
Northampton, MA 011060 Two Sets of Studural Plans
of phone 413-587-1240 Fax 413-587-1272 Plot/Slte Plans
Other Specify
APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING
SECTION 1 -SITE INFORMATION
1,1 Property Address: This section to be completed by office
63 Chestnut Ext Lot 22 Map Lot Unit
Zone Overlay District
_ Elm St.District,,,,,, _� CB District
SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT
j,1 Owner of Record:
Joshua Birk 63 Chestnut Ext Lot 22, Leeds MA 01053
Name(Print) Current Mailing Address: (413)841-1737
Telephone
Signature
$.2 Authorized Agent:
SolarCity Corp/Victoria Junck 604 Silver St Agawam MA 01001
Name(Pring Current Mailing Address-
/
ddress:
/// -7 7 /71,12(7,
/71�
r. / �l J 978-215-2367
Stere Telephone
SECTION 3-ESTIMATED CONSTRUCTION COSTS
Item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building 5 000 (a)Building Permit Fee
2. Electrical 1 1,000 (b)Estimated Total Cost of
Construction from(S) ,
3. Plumbing Building Pennit Fee 17-; m,
4. Mechanical(HVAC)
S. Fire Protection
8. Total=(1 +2+ 3+4+5) 16,000 Check Number 77S'S6Y
This Section For Official Use Only
•
Building Permit Number: Date
f � "���ir
Sgate .ef%G• /O
Buiidcg Comnisaianertinspeciur of Buildings Date
Section 4. ZONING Alt Information Must Be Completed. Permit Can Be Denied Due To Incomptete Information
Existing Proposed Required by Zoning
This column to be filled in by
Building Department
Lot Size
Frontage
Setbacks Front
Side L: R: L: R:
Rear
Building Height
Bldg. Square Footage
Open Space Footage
(Lot area minas bldg&paved
parkinE)
#of Parking Spaces
Fill:
(volume&Location)
A. Has a Special Permit/Variance/Finding ever been issued for/on the site?
NO DONT KNOW YES
IF YES, date issued:
IF YES: Was the permit recorded at the Registry of Deeds?
NO DON'T KNOW YES
IF YES: enter Book Page and/or Document#
B. Does the site contain a brook, body of water or wetlands? NO DONT KNOW YES
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained Obtained , Date Issued:
C. Do any signs exist on the property? YES NO
IF YES, describe size, type and location:
D. Are there any proposed changes to or additions of signs intended for the property? YES NO
IF YES, describe size, type and location:
E. WII the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES NO
IF YES,then a Northampton Storm Water Management Permit from the DPW is required.
SECTION 5-DESCRIPTION OF PROPOSED WORK(check all am/beadle)
New House Addition Replacement Windows Alteration(s) Roofing
Or Doors
Accessory Bldg. Demolition New Signs ( j Decks I I Siding[ I Others, . J�
Brief Description of Proposed
Work: Install solar electric panels to roof of existing home,to be interconnected with homes electrical system.
Alteration of existing bedroom Yes No Adding new bedroom Yes No
Attached Narrative Renovating unfinished basement Yes No
Plans Attached Roil -Sheet
Ga.If New house and or addition to existing housing. complete the following:
a Use of building: One Family Two Family Other
b. Number of rooms in each family unit; Number of Bathrooms
c. Is there a garage attached?
d. Proposed Square footage of new conduction. Dimensions
e. Number of stories?
f. Method of heating?_ Fireplaces or Woodstoves Number of each
g. Energy Conservation Compliance. Massoheck Energy Compliance form attached?„
h. Type of construction
i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No
j. Depth of basement or cellar floor below finished grade
k. Will building conform to the Building and Zoning regulations? Yes No
I. Septic Tank City Sewer Private well City water Supply
SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
i Joshua Birk ,as Owner of the subject
property
hereby authorizeSOLARCITY
to act on my behalf, in all matters relative to work authorized by this building permit application.
06/17/2016
Signature of Owner Date
i, SOLARCITY CORPNICTORIA JUNCK as owner/Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury
SOLARCITY CORP/VICTORIA JUNCK
Punt Nae
/// 111 06/17/2016
Ji90 Or/Agent `^' � - Date
SECTION B-CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor. Not Applicable 0 '
Name of License Noldet_SOLARCITY/JEREMY GRAVES 108706
License Number
604 SILVER ST AGAWAM MA 01001 _ 02/23/2019
Address Expiration Date
/ 74-279-7650
Sig Telephone
9.Registered Home Improvement Contractor: Not Applicable 0
SOLARCITY CORP/VICTORIA JUNCK 168572
Company Name Registration Number
604 SILVER ST AGAWAM MA 01001 ` 03/08/2017
Address i Expiration Date
rir Arlo//Mr� xif - Telephone
ji Sr
978-215-2367
SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L,C.152.§25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes ❑ No 0
11. - Home Owner Exemption
The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(I) or two(2)families
and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts
as supervisor.CMR 780. Sjxth Edition Section 108.3.5.1.
Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there
is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm
structures.A person who constructs more than one home in a Mm-year period shell not be considered a homeowner.
Such`homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/sheshall be
responsible for all such work performed under the building permit.
As acting Construction Supervisor your presence on the job site will he required from time to time,during and upon
completion of the work for which this permit is issued.
Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to
Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s)
you hire to perform work for you under this permit.
The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of
Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated.
Homeowner Signature_ _
e
14 The Commonwealth ofMassnc'huxetts
Department u/Industrial Accidents
IsEtOWs..11 Mike ofInvestigation.s
� n�27:.`, 600 llianhington Street
<„=+�[ Xauon,MA 02111
mvrv.n amgoWdia
Workers' Compensation Insurance Affidavit liuiklers/CmrirnctursfElectricians/Pluinbers
Applicant Information Please Print LeeibIY
Name{Bushxss'urganinummindiriduai): SOLARCITY CORP. ._______
Address: 3055 CLEARVIEW WAY
City/Siatctlip: SAN MATEO, CA 94402 ('hnnc tt: 888-765-2489
Are yam an employer?Cheek the appropriate bus: Type of prided(required): 1
1.0 I Intra employer with 5000 _ R. EI I ant a general contractor and I h 1I New construction
employees(toll arnPra part-time).* have!OS the sub-eoMrm tors
2.0 I Inn a sole mistletoeor partner_ listed on the attached sheet.I 7. 0 Remodeling
drip and have no employees 'These nth-eim'm1ors have H. 01)emoliliem
working )la in in nny capacity. workers'cent. insurance. 4. [1 Building addition
(No workers' coue.insunnruc 5. 0 We are a co partition owl its
required.] o ficer:/titheexen'isxl their
10-0 Electrical repaint or additions
3.[1 1 am a homeowner duiug all wink fight nfexempiioo per MCA. 11.0 thumbing repairs or additions
tot:dr.INa waiters nnup. c. 152 41('11•and w r have no 12.0 Roorivp'ks
inscnnnce rrxluired.I' employees. I No welters I1L1 Other
comp.insurance requtint.l —'...... ____
-An}amnesia attathecb tins at wasi Axe till rat the woks;trim.4ntinq Sill amisus arwawrvdetmegke irtfinm:uirn. .. .—
'nmainoeui ion,.Milail aril smith a iaaiiading the,lie thing alWilli,tint/ilia)hits InsoleCuIIIinicL.Baal submit a nem a1MM it imtlesinu smlr
4'unuunmv Mat dad.lht' Ion mea;ninda.bs.mahYumal shim NIwtbig ihu nwnr'milk aaa.cunamu.ynllln'n u,nkrr umT,lml.t' inlimnwiun,
/nor an envlh i' r that is prau*ling sorrierr'compensation nunroner far iffy employees. Belem ix the police run//rib the
ittftMnntfAN. 'Zurich j{,,, / comp
Insurance Comp-any Nato.:: 'Zunrich I'Aberl insurance compaar
Policy a at Self ins. I.iv. a: w C- Di8201-4 -O6 .. .__ I:xpimiion nate: Off 01-1l0
(/�� •[.�j �a
Joh Site Atuhrns: ,,j' f 1." (t-V �'e^��_... .' ('ityistntrttip:. _l '_i) K
Atinei,it copy of 1 hr norkeri cool peonal ion }Miley(Weiarnl iuu page(showing the polity number and expiration ii an•).
Pailorc to mxurc coverage as Inquired mtder Se:tinn 25A ol'h1(d. c. I52 can Tend Its IIw imposition of criminal penalties oft
line tip to 51.51111Ap wud/or our-year imprisonment,as well as civil prrudlies in ale limn ON STOP WORK ORDER and a Ibm
or up to$2 fat0)a thy against the V iolottx: Be advised that 0 cops or this statement may he forwarded to the( dice of
in veilgal tonw of Ilk DIA for ittnlmfaf•t'WC'?r yeti 0ci1inn.
-_—
l da hereby r'rrlifl ander Mr pelt m 'pr'nnaies ofrj
perjury thin she information provided rawer is Our and comfit
Si>Y ; . , / 4 �- _"-''". et _ orae: CAI)I 17/1U
Plume ay. .. _...._.--- . ...
--- . _ —_.. _--_ _
Official ase OW. nn ami ogee in this arra,in he rotnplrted Ify vire or lama aflittat
City or Town: l'enaittIieciise d
Issuing Auihorily (circle cure):
I. Board of Ilea Ilk 2. Building I)vpaiinavat .Y. City/Iowa Clerk 4. Electrical Inspector 5. Plumbing Inspeo(ar
6,Other_ ._
Ctmttwl Perr:wr•. _"_._ .__..___._-_ l bent 11: ....._. 1
AIC9RO° CERTIFICATE OF LIABILITY INSURANCE DATE NIMUONYWI
4W...� 00/11/2015
THIS CERTIFICATE 19 ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES MOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. INS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN 11.4E ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE!OLDER,
IMPORTANT: If 1h certificate holder Is an ADDITIONAL INSURED,the polirypea)must be endorsed. If SUBROGATION IS WAIVED,subject to
the terms and conditions of the policy,certain polities may require an endorsement. A statement on this certificate does not confer rights to the
certificate holder in Neu of such endarsementla).
RROOUCtR CONTACT
RSLI NSYS INSULUNRE SERVICES PHON:
NE I NA _. ow
345CAUKANG STREET.aid 1300 LALORNExt _.. . L.M/EFS _... .
CALIFORNIA LICENSE ND.M311S1 _AONNE
PMIEsa_
SAN FRANCISCO,CA 94109 MSVPEPS _ - -
Mtn Suwon Smtil1i)13E3M I IAFYYNmNG nu2RAG5 NNCP
098.301STNOGAWUE1610NS0RA Nod Melon lnsuancn Company 16515
191V(`�L'u an _.._ NNt
9ERB{NIA _ .. 4N/A.
30MCNtanemYtay NSllaIXC:WA tWWA _.
ENAMOR.CA 94102 NSUPFR07Ann Znr CnlryWinra CiUnlwy 40112 .
USURER E.
INSURER
SEMt2I
COVERAGES
ToC CERTIFICATE NNUMBER: SEENSUED REVIMEDNBOM@ER:4
INDICATED.N15 IS ED{NOTWI HSTA TIME PAYIRE UI NEMENt TE LISTED 9E.DW NAVE 8£FN ONTR CO TRE THERiEQ CUMEN DROVE RECT TOLtCY P£TOO
CERNOTWITHSTANDING BE SSUEDdO ANY PERTAIN,
TH.TERN OR COAFD MYHE CONTRACT OR SCRJO DOCUMENT SUS RESPECTTTOTO WM:CEERMTHIS
EXCLNS MAY O ISSUEDDIS OR MAY PERTAIN, THE INSURANCE N AFFORDED HRY THE POLICIESD DCO@BED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.COE
writ moat SUS/ vdICY EFr T>Oucv eRti t-
LTR TYPE nFIN911RANCE NW WWI POLICY NUMBER �BSSTAVYYWI IMW/MYYVVI I UMTS
A IX !COMMERCIAL GENERAL!JAUNT' 01Dh164m600 MOND CNDiR015 _EACROOCURRIINCS 5 3.WU.UW
a+MR RACE i., oCcUR i F 9ESk6FNaYt el,e 5 3,430960
X SIR_ MOOD _ SNOB
PERSONAL A AW INJURY 5 3000000
SEU'L AGGREGATE UNIT AGRIESFER GENERAL AGGREGATE E 60110.000
X POLICY( IT&. 1 IPRc cxs COMP/OP AW,S ,. 600,00.
JLCi I. f LOO
cram
(9
A Ae2aMJ81,FLuaR.rrc BPRTiA$➢iFDI gM1ttZOtS 'L`3'J1Q015 L�HOLP/FINDS LINT y W "
MEND
X IANY
LLOWIE • ' EDGILY NJURY(Kr Frtaml .5 -..
.K AUTOS EG M AUTOS
EOED PRC INJURY(FM9cuMne S
NREM AUTOS .x ALTO PROPERTY MaME E -.
I IFETENFIesall.
S
WOO
UMEREIA MMS 4 I OCN R
C ! EFCHOCCNYNCE S
EXCE55UAD f ICWNIvNAD1 /AGGREGATE 6
•. DEOI IRFTPNTIONS I I
D WORKERSCVRNMA1RlN t�11 IS
W4013'401A INIA06) OMPU2015 090/XI'tl X IPE14 ORH
*HO EMPLOYERS'flA kL aSTA Uttl I..__ER
A ANY PROPRR(NpARTNERIERECURVE Y1NI IkKOIE0015WIMA) L601^N 15 WN1lX116 .EL EASHAmtaxi rE -.1.OW-
NIA
aF sdaary art EKLtS®i t -
{IIyaWFyyq�NRi ( CFL" LCTI}n F:$533.DX1 lEL�£ASE.(A EN E LEOU00
I liagrA I oc°Pi'NAIIONS below E L DISEASE.POLIO,L E 1,000003
I
I
M6VMTONWOPERAiS1N51 mAMM I VIXnCLES.(ACCRO UN,.Manus,HectlvNS+M.ax,®y be abutted R,me weep Is mRM1eCI
DONN Nano/TN.
CERTIFICATE HOLDER CANCELLATION
SalarOly Gorpor 1iOn SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BF CANCELLED BEFORE
'HSS Claanww Way THE EXPIRATON DATE THEREOF, NOTICE WILL BE OEI.hFAED IN
San MARFA 5302 ACCORDANCE MATHTHE POLICY PROVISIONS.
AUTNORMEURWRESENTA11VE
of March RIM a Iaw,anoo Rmifl
Charles Harinder c.G h._
®1385-2014 AGGRO CORPORATION. AN rights resenred.
ACORD 2S(2h14/D1) The ACORD name and logo aro registered marks of AGORA
Office of Consumer AI lairs and Business Regulation
10 Park Plaza - Suite 5170
Boston, Massachusetts 02116
Home Improvement Contractor Registration
• Registration: 168572
Type: Supplement Card
SOLAR CITY CORPORATION Expiration: 3/8/2017
JEREMY GRAVES
3055 CLEARVIEW WAY
SAN MATEO, CA 94402
I:IMake Address and return card. Hark reason for change.
Address Renewal Employment Lost Card
Ocoee ortossumer ABaln d Runners Regulation License or registration valid fur individul use only
.. HOME IMPROVEMENT CONTRACTOR before Ibe expiration date. If found return In:
Office of Consumer Minim and Rosiness Regulation
Registration: 160572 Type: 10 Park Piave-Suite 5170
Expiration: 3/9/2017 Supplement Car Boson,MA 02116
SOLAR CITY CCHVF IWA T Ir'N
JEREMY GRAVES
20 ST MARTIN STREET BLO 211N1 •...•. -r2f. __
PstARLBOROuGH.MA 01752 -1'mbnxretom Not valid..about signature
OSS, c
CS-108708 ea)
JEREMY GRAVES 4 take
179 BRIGHAM STREET
Marlborough MA 111752
02/23/2019
, ., C//t t (/NI/Erie'(Cetl/fl; 'Mile. --eir��»es, //;
Office of Consumer Affairs end Business Regullatlon
10 Park Plaza - Suite 5170
Boston, Massachusetts 02116
Home Improvement Contractor Registration
Registration: 168572
Type: Supplement Card
Expiration: 3/8/2017
SOLAR CITY CORPORATION
VICTORIA JUNCK - - - - - - - --- ---
3055 CLEARVIEW WAY
SAN MATEO, CA 94402 ----------- --- - - - --
Update Address and return card.Mark reason for change.
a iuo-mn Address - Renewal Employment `_I Lost Card
Office Consumer Affairs&Business Regulation License or registration valid for individul use only
ya,,SOME IMPROVEMENT CONTRACTOR before the expiration date. If found return to:
: -h titration. Office of Consumer Affairs and Business Regulation
Registration: 168572 Type: 10 Park Plaza-Suite 5170
Expiration: 3/8/2017 Supplement Card Boston,MA 02116
SOLAR CITY CORPORATION
VICTORIA JUNCK
24 ST MARTIN STREET BLD 2UNI e
�.1AALBOROUGH,MA 01152 Undersecretary Not valid without. _ attire
DocuSign Envelope ID:C36381C0-OAA54FF3-9E62-7817A4467CFF
SolarCity PPA
Customer Name and Address Installation Location Date
Joshua Birk 63 Chestnut Ext Lot 22 5/31/2016
63 Chestnut Ext Lot 22 Leeds,MA 01053
Leeds,MA 01053
Here are the key terms of your Power Purchase Agreement
$0 13 . 70 20yrs
System installation cost Electricity rate 9/kWh Agreemen gm
initial here Initial her
DS
The SolarCity Promise
•We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. -.. Initial here
•We warrant all of our roofing work.
OS
•We restore your roof at the end of the Agreement. �/
•We warrant, insure,maintain and repair the System. _ _. . . -.. . Initial here �j
•We fix or pay for any damage we may cause to your property.
•We provide 24/7 web-enabled monitoring at no additional cost.
•The rate you pay us will never increase by more than 2.90%per year.
•The pricing in this Agreement is valid for 30 days after 5/28/2016.
Your SolarCity Power Purchase Agreement Details
Your Choices at the End of the Initial Options for System Purchase:
Amount due at contract signing Term: •At certain times,as specified in
•SolarCity will remove the System at no the Agreement,you may
Est.amount due at installation cost to you. purchase the System.
90 •You can upgrade to a new System with •These options apply during the 20
the latest solar technology under a new year term of our Agreement and
Est.amount due at building inspection contract. not beyond that term.
90
•You may purchase the System from
Est.first year production SolarCity for its fair market value as
5,954 kWh specified in the Agreement.
•You may renew this Agreement for up to
ten(10)years in two(2)five(5)year
increments.
3055 Clearview Way, San Mateo,CA 94402 1888.765.2489 I solarcity.com 1875101
Power Purchase Agreement,version 9.2.0,March 28,2016
SAPC/SEFA Compliant
Contractors License MA HIL 168572/EL-1136MR
Document generated on 5/28/2016 •
Copyright 2008-2015 SolarCity Corporation,All Rights Reserved
-re.
DoseSgn Envelope a C36381CODAA5-4FF39E62-78I7A4467CFF
23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in
YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and l acknowledge that)have received a
TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement.
DATE YOU SIGN THIS CONTRACT, SEE EXHIBIT 1 THE
ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Joshua Birk
EXPLANATION OF THIS RIGHT, roowes:we nr:
24. ADDITIONAL RIGHTS TO CANCEL. Signature: Ael4a
IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL
THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: 5/31/2016
THIS PPA AT NO COST AT ANY TIME PRIOR TO
COMMENCEMENT OF CONSTRUCTION ON YOUR HOME.
25. Pricine
The pricing in this WA is valid for 30 days after S/28/2016. customer's Name:
If you don't sign this PPA and return it to us on or prior to
30 days after 5/28/2016,SolarCity reserves the right to Signature:
reject this PM unless you agree to our then current pricing.
Date:
Power Purchase Agreement
SolarCity
approved
Signature: "`—
Lyndon Rive, CEO
Date: 5/28(2016
ONO
Version#55.7-TBD
a . arCity.
SolqN OF
lune 16, 2016 O
f CHRIS H. KIM `r"
3 CIVIL
RE: CERTIFICATION LETTER 524300 F.
Project/Job# D102202 "%Et/
Project Address: Birk Residence -9 (d
63 Chestnut Ext Lot 22
Leeds, MA 01053
AHJ Northampton
SC Office Springfield
Dig itaPly signed by Chris Kim
Design Criteria: Chris Kim Lo°a„on:aaa 76=,:33:563,3
Date.Nl6Mvr61933i6
mm
-Applicable Codes = MA Res.Code, 8th Edition,ASCE 7-05, and 2005 NDS
- Risk Category = II
-Wind Speed =90 mph,Exposure Category C
-Ground Snow Load=40 psf
- MP2: Roof DL= 9.5 psf, Roof LL/SL = 28 psf(Non-PV Areas),Roof LL/SL = 28 psf(PV Areas)
Note: Per IBC 1613.1; Seismic check is not required because Ss =0.22309 < 0.4g and Seismic Design Category(SDC) = B< D
To Whom It May Concern,
Ajobsie survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCty.
Structural evaluation was based on site observations and the design criteria listed above.
Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading
indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions
adopted/referenced above.
Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the
manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for bading.
The PV assembly hardware specifications are contained in the plans/docs submitted for approval.
Version#58.7-TBD •
SolarCity
HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES
Landscape Hardware-Landscape Modules'Standoff Specifications
Hardware X-X Spacing X-X Cantilever Y-Y Spacing I Y-Y Cantilever Configuration Uplift DCR
MP2 R" 24" 39" NA Staggered 40.9%
Portrait Hardware-Portrait Modules'Standoff Specifications
Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR
MP2 48" ll" 65" NA Staggered 45.3%
StructureMounting Plane Framing Qualification Results
Type Spacing Pitch Member Evaluation Results
MP2 Pre-Fab Truss @24 in.0.C. 25° Member Analysis OK
Refer to the submitted drawings for details of information collected during a site survey. Al member analysis and/or evaluation is based on framing information
gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC.
0 ]Inerae• r arMatea.0 ] Oc !c5"^[ ! lO t R°Ni�r)r r' car)rJ 1 +arcitr zm
STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP2
Member Properties Summary
MP2 Horizontal Member Spans Ratter Properties
Overhang 116 ft Actual W 1.50"
Roof System Pro Span 1 7.80 ft Actual D 5.50"
Number of Spans(win Overhang) 3 r Span 2 7.33 ft Nominal Yes
Roofing Material Comp Roof Span 3 6.97 ft A _ &.25 k1^2
Re-Roof No Span 4 S, 7.56 in.^3
Plywood Sheathing Yes Span 5 I, 20.80 in.^4
Board Sheathing None Total Rake Span 25.66 ft TL De0'n Limit 120
Vaulted Ceding No PV 1 Start 130 ft Wood Specks SPF
CoWng Finish 1/2"Gypsum Board IN 1 End 22.50 ft Wood Grade #2
Rafter Slope 25° PV 2 Sbrt Fp 875 psi
Rafter Spacing 24"O.C. PV 2 End F. 135 psi
Top Lat Bradng FuN PV 3 Start E 1400000 psi
Sot Lat Bracing At Supports PV 3 End Em;,, 510000 psi
Member Loading Summary
Roof Pitch 6/12 Initial Pitch Adjust Non-PV Arms PV Areas
Roof Dead Load DL 9.5 psf x 1.10 10.5 • f 10.5 •sf
PV Dead Load PV-DL 3.0 psf I x 1.10 3.3psf
Roof Live bed RLL 20.0['sr z 0.93 18.5 psf
Live/Snow Load LL/SL''' 40.0 psf x 0.7 I x 0.7 iii 28.0 psf 280 psf
Total Load(Governing LC) Ti. 38.5 psf 41.8 psf
Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-21 2. pf=0.7(Ca(CD(Is)Py; CC=0.9,ce=1.1,Is 1.0
Member Design Summar/(per NDS)
governing Load Comb CD CL(+) CL(-) CF Cr
D+5 1.15 1.00 0.78 1.3 1,15
Member Analysis Results Summary
Governing Analysis1 Max Demand 0 Location Capacity DCR Result
Bending(-) Stress 1 -768 psi 9.0 ft -1168 psi 0.66 Pass
CALCULATION OF DESIGN WIND LOADS- MP2
Mounting Plane Information
Roofing Material Comp Roof
Roof Slope 25°
Rafter Spacing 24"O.C.
Framing Type/Direction Y-Y Rafters
PV System Type SollarCity SleekMount'M
Zep System Type ZS Comp
Standoff(Attachment Hardware) _ Comp Mount SRV
Spanning Vents No
Wind Design Criteria
Wind Design Code ASCE 7-05
Wind Design Method Partially/Fully Enclosed Method
Basic Wind Speed V 90 mph Fig.6-1
Exposure Category C Section 6.5.6.3
Roof Style Gable Roof Fig.6-118/C/D-14A/8
Mean Roof Height I h 15 ft Section 6.2
Wind Pressure Calculation Coefficients
Wind Pressure Exposure K, 0.85 Table 6-3
Topographic Factor Ko 1.00 Section 6.5.7
Wind Directionality Factor Ka 0.85 Table 6-4
Importance Factor I 1.0 Table 6-1
Velocity Pressure tin qh = 0.00256(Ks)(Kzt)(Kd)(VA 2)(I) Equation 6-15
15.0 psi
r wind Pressure
Ext. Pressure Coefficient(Up) GCp(Lip) -0.88 Fig.6-118/C/D-14A/13
Ext.Pressure Coefficient(Down) GCp(Down) 0.45 Fg.6-IIB/C/D-14A/B
Design Wind Pressure p p = qh(GCp) Equation 6-22
Wind Pressure Up Paw -13.1 psf
Wind Pressure Down Pawns ns 10.0 psf
ALLOWABLE STANDOFF SPACINGS
X-Direction Y-Dinxtlon
Max Allowable Standoff Spacing Landscape 72" 3g"
Max Allowable Cantilever Landscape 24" NA
Standoff Configuration Landscape Staggered ,-.
Max Standoff Tributary Area Trib 20 sf
PV Assembly Dead Load W-PV 3.0 psf
Net Wind Uplift at Standoff T-actual -224 lbs
Uplift Capacity of Standoff T-allow 548 lbs
Standoff Demand/Capacity DCR I 40.9%
X-Direction Y-Direction
Max Allowable Standoff Spacing Portrait 48" 65"
Max Allowable Cantilever Portrait 17" NA
Standoff Configuration Portrait Staggered
Max Standoff Tributary Area Trib 22 sf
PV Assembly Dead Load W-PV 3.0 psf
Net Wind Uplift at Standoff T-actual -248 lbs
Uplift Capacity of Standoff T-allow 548 lbs
Standoff Demand/Capacity DCR 45.3%