38a-070 (2) 163 GROVE ST BP-2016-1400 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38A-070 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2016-1400 Project# JS-2016-002414 Est. Cost: $35589.50 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: ASTRUM SOLAR 188228 Lot Size(sq. ft.): 15507.36 Owner: PEEPLES GABRIEL Zoning: URB(100)/ Applicant: ASTRUM SOLAR AT: 163 GROVE ST Applicant Address: Phone: Insurance: 15 AVENUE E (508) 259-2387 WC HOP KINTONMAO1748 ISSUED ON:5/27/2016 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 34-9.01 KW SOLAR PANELS TO ROOF POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: of/7//� ^„ � Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oii: Insulation: v KFinal: Smoke: Final: tp I THIS PERMIT MAY BE REVO D1 Y T. CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND ' AL.. frp:0:1 Certificate of Occu•anc • ' /1 1 I Si nature: U'`-{�� FeeType: Date Paid: Amount: Building 5/27/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2016-1400 APPLICANT/CONTACT PERSON ASTRUM SOLAR ADDRESS/PHONE 15 AVENUE E HOPKINTON (508)259-2387 PROPERTY LOCATION 163 GROVE ST MAP 38A PARCEL 070 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid 76 C.1,/G " /0€ (20 Building Permit Filled out Fee Paid Typeof Construction: INSTALL 34-9.01KW SOLAR PANELS TO ROOF New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 188228 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: proved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management mo Signature of Building 0 cial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. y:. i.i qtr: rar • • ,qs. `cr. The Commonwealth of Massachusetts a Board of Building Regulations and Standards FOR �`4 MUNICIPALITY Massachusetts State Building Code,780 CMR USE Building Pen-nit Application To Construct, Repair, Renovate Or Demolish a Revised Mar 2011 One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date Applied: Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map& Parcel Numbers 163 Grove Street, Northampton, MA 01060 1.1a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(N1.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 tone: Outside Flood Zone? Municipal 0 On site disposal system 0 Cheek i f vesD SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Gabriel Peeples Northampton, MA 01060 Name(Print) City,State,ZIP 163 Grove Street (508) 386-8564 michael.whalen@directenergysolar.com No.and Street Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition ❑ Demolition 0 Accessory Bldg. 0 Number of Units Other✓ Specify:SOLAR INSTALLATION Brief Description of Proposed Work2: rooftop solar installation consisting of(34)26Sanels and(34)Enphase microinverters SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) I.Building s 33,089.50 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical S 2500.00 ❑Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x_ 3. Plumbing S 2. Other Fees: $ 4.Mechanical (HVAC) S List: 5. Mechanical (Fire S Suppression) Total All Fees:$ 7 5 Check No1CyGCl Check Amount: 75- Cash Amount: 6.Total Project Cost: S 35,589.50 0 Paid in Full 0 Outstanding Balance Due: lNI\01/4)v\:\--C`‘ v\ 5k - SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CSFA083813 01/30/2017 Christopher J. Murphy License Number Expiration Date Name of CSL Holder 134 Burt St. List CSL Type(see below) No.and Street �+ Type Description Norton, MA. 02766 66 U Unrestricted(Buildings up to 35,000 cu.Ii.) R Restricted 1&2 Family Dwelling City(Fown,State,ZIP M Masonry RC Roofing Covering WS Window and Siding (508) 386-8564 michael.whalen@directenergysolar.com SF Solid Fuel Burning Appliances I Insulation Telephone �� Email address D Demolition SI�STRU SMEAR!Olr Improvement eA So er `nst p 168218 1/19/2017 Energy � ft�trlstop�eF J. Murphy HIC Registration Number Expiration Date I-Itc CVmRaar�Dlame or RIC Registrant Name 1 H t. michaet.whalen@directenergysotar.com Nt14bp cin on, MA. 01748 (508) 386-8564 Email address City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c,152.§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes No El SECTION 7a OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize ASTRUM SOLAR/area Energy Solan Christopher J.Murphy to act on my behalf,in all matters relative to work authorized by this building permit application. Print wrier's Name(Electronic Signature) Date SECTION 7b:OWNER1.OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true urate to the ' my knowledge and understanding. Ohns 11erS tkIS--t —2P1 t,o Print Own s or Authorized Age� sN Electro ignatur , Date NI ES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor.License can be found at www.rnass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of halflbaths Type of heating system Number of decks!porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost- 1 ACORO DATE(MM/DDIYYYY) CERTIFICATE OF LIABILITY INSURANCE Page 1 of 1 05/25/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER.AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAMF. Willis of Texas, Inc. PHONE FAX c/o 26 Century Blvd. ( v.EXx1)• 877-945-7378 pun No) 888-467-2378 P.O. Box 305191 ADDes s certificates@willis.com Nashville, TN 37230-5191 INSURER(S)AFFORDING COVERAGE RAC* INSURERA ACS American Insurance Company 22667-302 INSURED Direct Energy and its majority owned INSURERB: Zurich American insurance Company 16535-305 subsidiaries and affiliates including INSURERC: Astrum Solar, Inc. dba Direct Energy Solar 7101 Riverwood Drive INSURER D: Columbia, MD 21046 INSURERE: r - INSURER F: COVERAGES CERTIFICATE NUMBER:24405844 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POUCIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED.NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN.THE INSURANCE AFFORDED BY THE POUCIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, aE�X� EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. �N�e I TYPEOFINSURANCEADDL BR pmn y�yyrPOLICY NUMBER / IJj TYYY) pmenomnrn- LIMITS A IX CONMERCIALOENERALWIBILRY XSLG27341226 1/1/2016 1/1/2017 _EEAACCHp�O�CCCURRENCE IS 1,000 000 CLAIMS-MADE X OCCUR PREMISES1 NTE nce) S 100 U00 X SIR: $100,000 MEDEXP(Anyoneperson) s 5000 PERSONAL&ADV I14JURY $ 1.000.000 GEN'LAGGREGATEUMITAPPUESPER: GENERALAGGREGATE S 1,000,000 POLICY JEC LOC PRODUCTS-COMPIOPAGG $ 1.000.000 011132: $ B AUTOMOBILE LIABIUTY BAP595396602 1/1/2016 1/1/2017 JETZWINGLELINIT $ 1,000,000 X ANY AUTO 1 9ODd.YINJURY(Per Person) IS _ ALL OWNED ' O BODILY INJURY(Per aoddenn $ HIRED AUTOS I NON-OWNED MORERTY DAMAGE UMBRELLA LIAB OCCUR EACH OCCURRENCE '5 EXCESS LIAR CLAIMS-MADE AGGREGATE S DED RETEN-ICN$ IS g WORKERS COMPENSATION WC595397302 1/1/2016 1/1/2017 X L PER O7H AND EMPLOYERS'LIABILITY �CTA7IITF FR B ANY PROPRIETOR/PARTNER/EXECUTIVEiN NIA WC595396902 1/1/2016 1/1/2017 E.L.EACHACCIDENT S 1,000,000 OFFICER/MEMBER EXCLUDED? Nxn)der _ELDISEASE-EI1£MPLOYES S 1,000,040 <ttMyya DESCRIPTIONOF OPERATIONS below EJLDISEASE-POUCYUMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS f VEHICLES(ACORD iOI,Additenai Remarks Scheduie,may be attached Ii more space is required) Re: Operations, 06/30/2016. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE City of Northampton 212 Main Street #100 Northampton, MA 01060 C Coll:4905088 Tp1:2010673 Cert:24405844 g 198072014ACORDCORPORATION.Allrightsreserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD COMMONWEALTH OF MASSACHUSETTS- .: DIVISION co! PROFESSIONAL LICENSURE •::;:" • 4,34, gitt!_ , �.��c.���-iJ:`• 'c�•7.:' .'���.L'�::'-��• cry. b'• >; . LICENSE Nar,1 BER EXPIRATION DATE SERIAL NUMBER = Office of Consumer Affairs d Business Regulation ..:.-'i ite ` )',f)firn,o-nweaite, olC)A4JJadm /1-, k10c 9. Park Plaza - Suite 5170 ' Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168228 I2{ ~ry ;--;.-?2 ,7.-:—...4/71' Type: Supplement Card ASTRUM SOLAR INC. trt =: . ' 1 Expiration: 1/19!2017 - ,t CHRISTOPHER MURPHY14 -, ;' 8955 HENKELS LANE STE 508 '�ti�,> � :� ANNAPOLIS, MD 20701 `- == :'=�_ ..ze t.f.: Update Address and return card.Mark reason for change. scni 0 20M-0511 - Address Renewal - Employment Lost Card //(- trr.m/or ir tee(IN 11 74,J.:(tekINr'1.; r. ---Office of Consumer Affairs&Business Regulation License or registration valid for individul use only 47.44 4 HOME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: q s} ,! • Office of Consumer Affairs and Business Regulation `r :Registration: 168228 Type: 10 Park Plaza-Suite 5170 \'mss-'' Expiration: 1/19/2017 Supplement Card Boston,MA 02116 ASTRUM SOLAR INC. DIRECT ENERGY SOLAR CHRISTOPHER MURPHY G �� 15 AVENUE E >.c:.-.�x_‘,.•-- _ ,i ,� HOPKINTON,MA 01748 Undersecretary 1; t Valid ' hout sig ure Massachusetts - Department of Public Safety Board of Building Reguiations and Standards C'un,tr u tiuii Supui-t i;4,1- I & 2 Family License: CSFA-083813 CHRISTOPHER J. ING �'r 134 BURT ST $ y NORTON MA 02766 ryi ; � �(Ii- )l �1f,. � ++ 1"7" Expiration Commissioner 01/30/2017 AOstructures Inc. PO Box 413 Carnelian Bay,CA 96140 A • 916.541.8586 structures www.AOstructures.com April 25, 2016 To: Direct Energy-MA 15 Avenue E Hopkinton, MA.01748 Subject: Certification Letter Peeples Residence 163 Grove Street Northampton, MA.01060 To Whom It May Concern, A jobsite observation of the condition of the existing framing system was performed by an audit team of Direct Energy-MA at the request of AOstructures, Inc..All attached structural calculations are based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review,including the plans and calculations only apply to the section of the roof that is directly supporting the solar PV system and its supporting elements.The observed roof framing is described below.If field conditions differ,contractor to notify engineer prior to starting construction. The roof structure of(Both Roof's)consists of composition shingle on roof plywood that is supported by pre-manufactured trusses that are spaced at @ 24"o.c..The top chords,sloped at 20 degrees,are 2x6 sections,the bottom chords are 2x6 sections and the web members are 2x4 sections.The truss members are connected by steel gusset plates.The max unsupported projected horizontal top chord span is approximately 8'-0". The existing roof framing system of(Both Roof's)is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The spacing of the solar standoffs should be kept at 48"o.c.with a staggered pattern to ensure proper distribution of loads. Design Criteria: • Applicable Codes=Massachusetts Residential Code,8th Edition,ASCE 7-05,and NDS-12 • Roof Dead Load=8 psf(Both Roof's) • Roof Live Load=20 psf • Wind Speed=90 mph, Exposure C • Ground Snow Load=40 psf - Roof Snow Load=28 psf Please contact me with any further questions or concerns regarding this project. Sincerely, Andrew Oesterreicher,P.E. Project Engineer Peeples Residence, Northampton, MA 1 AOstructures Inc. 790 Carnelian Circle Carnelian Bay,CA 96140 A • 916.541.8586 www.AOstructures.com structures Gravity Loading Roof Snow Load Calculations p�=Ground Snow Load= 40 psf pf=0.7 Ce C,I pg (ASCE7-Eq 7-1) Ce=Exposure Factor= 1 (ASCE7-Table 7-2) C,=Thermal Factor= 1 (ASCE7-Table 7-3) I=Importance Factor= 1 pf=Flat Roof Snow Load= 28.0 psf Ps=Cspf (ASCE7-Eq 7-2) Cs=Slope Factor= 1 p,=Sloped Roof Snow Load= 28.0 psf PV Dead Load=3.8 psf(Per Direct Energy-MA) Roof Dead Load (Both Roofs) Composition Shingle 4.00 Roof Plywood 2.00 2x6 Top Chords @ 24"o.c. 1.15 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.85 Total Roof DL(Both Roofs) 8.0 psf DL Adjusted to 20 Degree Slope 8.5 psf PPPnloc RPCIr1Pnt- Nnrthamntnn MA 9 AOstructures Inc. 790 Carnelian Circle Carnelian Bay,CA 96140 A . 916.541.8586 www.A0structures.com structures Wind Calculations Per ASCE 7-05 Components and Cladding Input Variables V/.rid Speed 90 mph Exposure Category C Roof Shape Gable/Hip Roof Slope 20 degrees Mean Roof Height 20 ft Effective Wind Area 19.3 ft Design Wind Pressure Calculations Wind Pressure P=qh*G*Cn qh=0.00256*Kz*Kzt*Kd*VA2*I (Eq_6-15) Kz(Exposure Coefficient)= 0.9 (Table 6-3) Kzt(topographic factor)= 1 (Fig.6-4) Kd(Wind Directionality Factor)= 0.85 (Table 6-4) V(Design Wind Speed)= 90 mph Importance Factor= 1 (Table 6-1) qh= 15.86 Standoff Uplift Calculations Zone 1 Zone 2 Zone 3 Positive GCp= -0.86 -1.51 -2.37 0.42 (Fig.6-11) Uplift Pressure= -13.67 psf -23.95 psf -37.63 psf 10.0 psf (Minimum) X Standoff Spacing= 4.00 4.00 2.67 Y Standoff Spacing= 5.50 2.75 2.75 Tributary Area= 22.00 11.00 7.33 Footing Uplift= -301 lb -263 lb -276 lb Standoff Uplift Check Maximum Design Uplift= -301 lb Standoff Uplift Capacity = 400 lb 400 lb capacity>301 lb demand Therefore,OK Fastener Capacity Check Fastener= 1 -5/16"dia Lag Number of Fasteners= 1 Embedment Depth= 2.25 Pullout Capacity Per Inch= 250 lb Fastener Capacity= 563 lb w/Cd=1.6&F.S.of 1.5= 602 lb 601.6 lb capacity>301 lb demand Therefore,OK PPPnIPC P ic1Pn/:P Nnrthamntnn SAA '� AOstructures Inc. 790 Carnelian Circle A • Carnelian Bay,CA 96140 structures 916.541.8586 www.AOstructures.com Framing Check (Both Roofs) PASS w=81 plf Dead Load 8.5 psf PV Load 3.8 psf Snow Load 28.0 psf 2x6 Top Chords @ 24"o.c. 0 Governing Load Combo=DL+SL < Member Span=8'-0" Total Load 40.3 psf Member Properties Member Size S(inA3) I (inA4) Lumber Sp/Gr Member Spacing 2x6 7.56 20.80 SPF#2 @ 24"o.c. Check Bending Stress Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1) 875 x 1.15 x 1.3 x 1.15 Allowed Bending Stress=1504.3 psi Maximum Moment = (wL^2)18 = 645.015 ft# = 7740.18 in# Actual Bending Stress=(Maximum Moment)I S =1023.5 psi Allowed>Actual—68.1%Stressed — Therefore,OK Check Deflection Allowed Deflection(Total Load) = U180 (E=1400000 psi Per NDS) = 0.533 in Deflection Criteria Based on = Simple Span Actual Deflection(Total Load) = (5*w*LA4)/(384*E*I) = 0.256 in = L/375 > L1180 Therefore OK Allowed Deflection(Live Load) = L1240 0.4 in Actual Deflection(Live Load) _ (5*w*LA4)I(384*E*I) 0.178 in L/540 > L1240 Therefore OK Check Shear Member Area= 8.3 inA2 Fv(psi)= 135 psi (NDS Table 4A) Allowed Shear = Fv*A = 1114 lb Max Shear(V)=w*L/2 = 323 lb Allowed>Actual--29%Stressed — Therefore,OK PPanIac Racirianra Nnrthamninn MAA d The Commonwealth of Massachusetts i . l (/. Department oflndrsstf'ialAccideirts e l 1 Congress Street,Suite 100 1>k..-..,4--,ss!' WWW.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name(Business/Organization/lndividual):Direct Energy Solar d/b/a Astrum Solar Inc. Address:195 Constitution Dr. City/State/zip:Taunton, MA 02780 Phone#:(508)614-0146 Are you an employer?Check the appropriate box: Type of project(required): LI I am a employer with 75 employees(full and/orpai1 time).* 7. ❑New construction 2.01 am a sole proprietor orpartncrship and have no employees working for me in 8. ❑Remodeling any capacity.[No workers'comp.insurance required.] 1.0I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. El Demolition 4.❑I am a homeowner and wilt be hiring contractors to conduct all work at my property. 1 will 10 El Building addition ensure that all contractors tither have workers'compensation insurance or are sole 11.[]Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached skeet 13. Roof repairs These sub-contractors have employees and have workers'comp.insurance.l 6.❑we arc a corporation and its officers have exercised their right of exemption par MGL e. PV Solar Install 14.1 Other 152,§1(4),and we have no employees.[No workers'comp,insurance required] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeownem who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractora that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have 1 . employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. raft an employer that is providing workers'compensation insurance for my employees. Below is the policy andj'obsite information. Insurance Company Name:Zurich American Insurance Company • Policy#or Self-ins.Lie.#:WC595397302 Expiration Date:01/01/2017 Job Site Address:163 Grove Street City/State/zip:Northampton, MA 01061 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c.152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as wel/as civil penalties in.the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement maybe forwarded to the Office of Investigations of the DIA for insurance coverage verific: '. • / Idohereby c,_tify ter he,aims aIpe.. es ofpeijury that the Informnallon provided above It'true and correct, _i:n• ure: _Ai i Date: L Phone/#: f .. �� (508) 386-8564 r Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone II: M215 - MICROINVERTER [elenPhase JENERGY E enphase .:: GY -ENERGY - Maximum energy production The Enphase Energy Microinverter PRODUCTIVE - Resilient to dust, debris and shading - Performance monitoring per module System improves energy harvest, increases reliability, and dramatically - System availability greater simplifies design, installation and RELIABLE than 99.8% - No single point of system failure management of solar power systems. The Enphase System includes the - Quick and simple design, installation S M ART and management microinverter, the Envoy Communications - 24/7 monitoring and analysis Gateway, and Enlighten, Enphase's monitoring and analysis software. SAFE - Low voltage DC - Reduced fire risk US enphase.com M215 MICROINVERTER TECHNICAL DATA Input Data (DC) M215-60 2LL-S22/S23 and M215-60-2LL-S22-NA/S23-NA (Ontario) Recommended input power(STC) 190-260W Maximum input DC voltage 45V Peak power tracking voltage 22V-36V Operating range 16V-36V Min./Max.start voltage 26.4V/45V Max. DC short circuit current 15A Max. input current 10.5A Output Data (AC) @208 Vac @240 Vac Maximum output power 215W 215W Nominal output current 1.0A (arms at nomina'dJration) 0.9A(arms at nominal duration) Nominal voltage/range 208V/183-229V 240V/211-264V Nominal frequency/range 60.0/59.3-60.5 Hz 60.0/59.3-60.5 Hz Extended frequency range 60.0/59.2-60.6 Hz 60.0/59.2-60.6 Hz Power Factor >0.95 >0.95 Maximum units per 20A branch circuit 25(three phase) 17 (single phase) Maximum output fault current 1.05 Arms,over 3 cycles;25.2 Apeak, 174ms duration Efficiency CEC weighted efficiency 96.0% Peak inverter efficiency 96.3% Static MPPT efficiency(weighted, reference EN50530) 99.6% Dynamic MPPT efficiency(fast irradiation changes,reference EN50530) 99.3% Night time power consumption 46mW Mechanical Data Ambient temperature range -40°C to +65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 17.3 cm x 16.4 cm x 2.5 cm(6.8" x 6.45" x 1.0")* Weight 1.6 kg(3.5 lbs) Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 *without mounting bracket Features Compatibility Pairs with most 60-cell PV modules Communication Power line Warranty 25-year limited warranty Monitoring Free lifetime monitoring via Enlighten softrware Compliance UL1741/IEEE1547, FCC Part 15 Class B CAN/CSA-C22.2 NO.0-M91,0.4-04,and 107.1-01 Enphase Energy, Inc. 142-00010 Rev 02 201 1st Street Petaluma, CA 94952 Phone: 877-797-4743 Fax: 707-763-0784 in=o(genphaseenergy.corn http://www.enphase.com . PR BF - 255 -265 ,, POLYCRYSTALLINE SOLAR MODULE The new Q.PRO BFR-G3 is the reliable evergreen for all applications, with a black frame design for improved aesthetics. The third module genera- II 11111 11111tion from Q CELLS has been optimised across the board: improved output III yield, higher operating reliability and durability, quicker installation and - more intelligent design. ��� n . IIIIIIli `_. INNOVATIVE ALL-WEATHER TECHNOLOGY PROFIT-INCREASING GLASS TECHNOLOGY IiIIllh • Maximum yields with excellent low-light • Reduction of light reflection by 50%, illyM and temperature behaviour. plus long-term corrosion resistance due • • Certified fully resistant to level 5 salt fog to high-quality • Sol-Gel roller coating processing. 'Ii ENDURING HIGH PERFORMANCE • Long-term Yield Security due to Anti LIGHTWEIGHT QUALITY FRAMEPID Technology', Hot-Spot Protect, • Stability at wind loads of up to 5400 Pa and Traceable Quality Tra.QT"". with a module weight of just 19 kg due • Long-term stability due to VDE Quality to slim frame design with high-tech alloy. Tested—the strictest test program. MAXIMUM COST REDUCTIONS SAFE ELECTRONICS • Up to 31% lower logistics costs due to EUPD RESEARCH E QCfLLS e1u•�o�rts • Protection against short circuits and higher module capacity per box. TOP BRAND PV Ann PienW„a,4, thermally induced power losses due to CJ,S•: 419) breathable junction box and welded EXTENDED WARRANTIES Zo�d 3, PMRST cables. • Investment security due to 12-year :4414. • Increased flexibility due to MC4-inter- product warranty and 25-year linear mateable connectors. performance warranty2. VDE Phntnn. Quality Tested QCEUS i ryn roiaer+;r But Polycrystalline J icy,°aira etch solar module 2013 ▪Feyent vcdut wn¢iRerne 11.1.2552 235 THE IDEAL SOLUTION FOR: ID.40032587 ®Rooftop arrays on Ground-mounted ®Rooftop arrays on commerciallindustri- solar power plants residential buildings 21 buildings 1 APT test conditions:Cells at-1000V against grounded,with conductive metal foil covered module surface, 25°C, 168h 2 See data sheet on rear for further information. Engineered in Germany Q CE LLS MECHANICAL SPECIFICATION Format 65.7in x 39.4in x 1.38in(including frame) 63.7':6,0..» (1670 mm x 1000 mm x 35 mm) >s6•,+r-•: Weigh 41.89 lb(19.0 kg) '-4, + I Front Cover 0.13in(3.2 mm)thermally pre-stressed glass ''"""""" 0n as~°" rl / with anti-reflection technology f ❑. '""' )r Back Cover Composite film ' _0 . # <1 Frame Black anodized aluminum _ Cell 6 x 10 polycrystalline solar cells Junction box Protection class IP67,with bypass6',:.,,,�.f'°" diodes i__ ,, I Cable 4 mm2 Solar cable;(+)x45.67 in(1160 mm),(-)245.67 in(1160 mm) 4., ,13"., a,. ODM., H Connector SOLARLOK PV4,IP68 0-3r,,6,.,.oiQi,3,3•,f.., :"3,s,..> ELECTRICAL CHARACTERISTICS PERFORMANCE AT STANDARD TEST CONDITIONS(STC:1000 W/m2,25'C,AM 1.5G SPECTRUM)' NOMINAL POWER(+5W/-0 W) [W] 255 260 265 Average Power P,/PP (WI 257.5 262.5 267.5 Short Circuit Current I, [A] 8.90 9.09 9.28 Open Circuit Voltage V. [V] 37.83 38.18 38.52 Current at Pero tete (Al 8.37 8.53 8.69 Voltage at 121eP Vere IV) 30.77 30.78 30.79 Efficiency(Nominal Power) n 1%] 215.3 215.6 215.9 PERFORMANCE AT NORMAL OPERATING CELL TEMPERATURE(NOCT:800 W/tn=,45 t3'C.AM 1.56 SPECTRUM)2 NOMINAL POWER(+5W/-0W) (WI 255 260 265 Average Power Pep, (W1 189.7 193.4 197.1 Short Circuit Current Iso [A] 7.18 7.33 7.48 Open Circuit Voltage V. IV) 35.22 35.54 35.86 Current at Pew few IA] 6.56 6.68 6.80 Voltage at Pe,p VAIN. [V] 28.92 28.94 28.97 Measurement tolerances SIC:±3%(P„,„);*10%(I,,,.,Imo,V.„°) 1 Measurement tolerances NOCT:t 5%(P,);±10%(Ix,V,,I..,V O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ii" -°crus At least 97%of nominal power during f s 2 i n _ x w,.°.6 b 7s.r�a first year.Thereafter max.0.6%degra y s • dation per year. At least 92%o'nominal power after ` iw „ 10 years. 2. At least 83%of nominal power after 2 " f' a 25 years. j a All data within measurement tolerances. Ir Full warranties in accordance with the 'r warrarty terms of the 0 CELLS sales IRRADIANCE(WWI organisation of your respective country. 0 a '3 w ]f Q f,,,a,,,,,,,,oq.m,,,,,,"N,I,,rnano,,,„ y The typical change in module efficiency at an irraciance of 200 W/mz in relation z, ., < m„mCORA s.,,.6*p..) to 1000 W/mz(both at 25°C and AM 1.5G spectrum)is-2%(relative). I TEMPERATURE COEFFICIENTS(AT 1000 W/113,25°C,AM 1.56 SPECTRUM) Temperature Coefficient of I, a 1%/K] +0.04 Temperature Coefficient of V. p (%/K] -0.30 g Temperature Coefficient of P,,,, y 1%/K] -0.42 NOCT [°F] 113 t 5.4(45 t 3°C) PROPERTIES FOR SYSTEM DESIGN o Maximum System Voltage V5,5 [V] 1000(IEC)!600(UL) r Safety Class II a Maximum Series Fuse Rating IA DCI 20 Fire Rating C E Max Load(UL)' [Ibs/ft21 75(3600 Pa) Permitted module temperature -40°F up to+185°F 2 on continuous duty (-40°C up to+85°C) a Load Rating(UL)' [lbs/ft21 75(3600 Pa) 'see installation manual s • QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION E UL 1703;VDE Quality Tested:CE-compliant; Number of Modules per Pallet 29 F IEC 61215 tEd.2);IEC 61730(Ed.1)application class A Number of Pallets per 53'Container 32 sAo P. Number of Pallets per 40'Container 26 P. 0 E Cf..0us PalletDimensions(LxWxH) 68.5inx44.5inx46.0in - L:`:11 (1740 x 1130 x 1170 mm) Pallet Weight 1323 lb(600 kg) o NOTE:Installation instructions must he followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha Q CELLS USA Corp. 80CI Irvine Certer Drive,suite 1250,Irvine CA 92618,USA I TEL+1 949 748 59 96 I EMAIL q-cells-uszegcells.com I WEB wew.q-cells.us Engineered in Germany Q CELLS Ecolibrium Solar ECOX Bill Of Materials Part Name Quantity ES10065 EcoX Connector Bracket,Large 34 ES10103 EcoX Clamp Assembly 84 ES10121 EcoX Coupling Assembly 27 ES10124 EcoX Landscape Skirt,32/33mm 9 ES10132 EcoX Power Accessory Bracket 34 ES10139 Trunk Cable Clip 68 ES10144 EcoX Junction Box Bracket 2(Optional) ES10184 PV Cable Clip 102 ES10186 EcoX North Row Extension 6 ES10195 EcoX Base,Comp Shingle 84 ES10197 EcoX Flashing,Comp Shingle 84 ES10201 EcoX Bonding Jumper 14 ES10297 EcoX Portrait Skirt,Single,32/33mm 1 EcolibriurnS(,l<rr Nt Roof Weights N 'f.flA In Conformance with Solar ABCs Expedited Permit Process Module Quantity: 12 Weight of Modules:497 lbs Weight of Mounting System:62 lbs Total Plane Weight:559 lbs Total Plane Array Area:216 ft2 Distributed Weight:2.59 psf Number of Attachments:31 Weight per Attachment Point:18 lbs Roof Design Variables Design Load-Downward:918 lbf Design Load-Upward:720 lbf Design Load-Downslope:460 lbf Design Load-Lateral:252 lbf F colibrium' , V Layout =J\ I 1 • • • . • T • • �- • • -----•-• ♦ • • • 4,111 • • I Skirt 1 Coupling = End Coupling ® Clamp End Clamp Note:If the total width of a continuous array exceeds 35 ft,break array to allow for thermal expansion and contraction.See Installation Guide for details. • North Row rxtension Warning:PV Modules may need to be shifted with respect to roof trusses to comply with • Bonding Jumper maximum allowable overhang. Ecolibriurn Siihr Plane Calculations (ASCE 7-05):A 0-", X ,t,t Roof Shape:Gable Edge and Corner Dimension:3.0 ft Attachment Type:Composition Shingle-ES Flashing Stagger Attachments:Yes Average Hoof Height: 16.0 ft Include Snow Guards:No Least Horizontal Dimension:15.0 ft Include North Row Extensions:No Roof Slope:20.0 day Preferred Landscape Spacing:48.0 in Truss Spacing:24.0 in Preferred Portrait Spacing:48.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.91 0.91 0.91 Roof Snow Load 30.6 30.6 30.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 30.6 30.6 30.6 psi Downslope:Load Combination 3 10.6 10.6 10.8 psf Down:Load Combination 3 29.2 29.2 29.2 psf Down:Load Combination 5 12.2 12.2 12.2 psf Down:Load Combination 6a 29.9 29.9 29.9 psf Up:Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 29.9 29.9 29.9 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 48.0 48.0 48.0 in Max Spacing Between Attachments With Rafter/Truss Spacing of 24.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Penmeter of PV Array 16.0 16.0 16.0 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 48.0 48.0 41.2 in Max Spacing Between Attachments With Rafter/Truss Spacing of 24.0 In 48.0 48.0 24.0 in Max Cantilever from Attachment to Perimeter of PV Array 16.0 16.0 13.7 in EcolibriumSolar Roof Weights EQQX In Conformance with Solar ABCs Expedited Permit Process Module Quantity:22 Weight of Modules:911 lbs Weight of Mounting System:106 lbs Total Plane Weight:1017 lbs Total Plane Array Area:395 ft2 Distributed Weight:2.57 psf Number of Attachments:53 Weight per Attachment Point:19 lbs Roof Design Variables Design Load-Downward:918 Ibf Design Load-Upward:720 Ibf Design Load-Downslope:460 Ibf Design Load-Lateral:252 lbf Ecolibrium Solar LayoutECOX i 1 II } I I I I III li Skirt - Coupling usi End Coupling O Clamp End Clamp Note•If the total width of a continuous array exceeds 35 ft,break array to allow for thermal expansion and contraction.See Installation Guide for details. • North Row Extension Warning:PV Modules may need to be shifted with respect to roof trusses to comply with • Bonding Jumper maximum allowable overhang. Ecolibrium Solar Plane Calculations (ASCE 7-05): B CQX Roof Shape:Gable Edge and Corner Dimension:3.0 ft Attachment Type:Composition Shingle-ES Flashing Stagger Attachments:Yes Average Roof Height: 17.0 ft Include Snow Guards:No Least Horizontal Dimension:16.0 ft Include North Row Extensions:No Roof Slope:20.0 deg Truss Spacing:24.0 in Preferred Landscape Spacing:48.0 in Snow Load Calculations Preferred Portrait Spacing:48.0 in Description Interior Edge Corner Unit Flat Roof Snow l oad 33.6 33.6 33.6 psf Slope Factor 0.91 0.91 0.91 Roof Snow Load 30.6 30.6 30.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 30.6 30.6 30.6 psf Downslope:Load Combination 3 10.6 10.6 10.6 psf Down:Load Combination 3 29.2 29.2 29.2 psf Down:Load Combination 5 12.2 12.2 12.2 psf Down:Load Combination 6a 29.9 29.9 29.9 psf Up:Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 29.9 29.9 29.9 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 48.0 48.0 48.0 in Max Spacing Between Attachments With Rafter/truss Spacing of 24.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter Of PV Array 16.0 16.0 16.0 in Spacing Results(Portrait) Description Interior Edge Corner Unit - Max Allowable Spacing Between Attachments 48.0 48.0 '41.2 in Max Spacing Between Attachments With Rafter/Truss Spacing of 24.0 in 48.0 48.0 24.0 in • Max Cantilever from Attachment to Perimeter of PV Array 16.0 16.0 13.7 in Ecolibrium Solar X Customer Info Name:Gabriel Peeples Email: Phone: Project Info Identifier:2794 Street Address Line 1: 163 Grove St Street Address Line 2: City:Northampton State:MA Zip:01060 Country:United States System Info Module Manufacturer:0-Cells Module Model:Q.PRO-G3-265 Module Quantity:34 Array Size(DC watts):9010.0 Mounting System Manufacturer:Ecolibrium Solar Mounting System Product:EcoX Inverter Manufacturer:Enphase Energy Inverter Model:M215 Project Design Variables Module Weight:41.4 lbs Module Length:65.7 in Module Width:39.4 in Basic Wind Speed:92.0 mph Ground Snow Load:40.0 psf Seismic:0.0 Exposure Category:B Importance Factor:II Exposure on Roof:Partially Exposed Topographic Factor:1.0 Wind Directionality Factor:0.85 Thermal Factor for Snow Load:1.2 Lag Bolt Design Load-Upward:820 lbf Lag Bolt Design Load-Lateral:288 lbf Module Design Moment—Upward:4875 in-lb Module Design Moment—Downward:4875 in-lb Effective Wind Area:20 ft2 Min Nominal Framing Depth:2.5 in Min Top Chord Specific Gravity:0.42 t