Loading...
16D-004 (10) 202 NORTH MAIN ST SM-2016-0045 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON IGIS#: 1281- -- _ _i IMap: ; -- 16D � Lot. - 004 _ S IEETMETAL PERMIT Lot: 001 Perm t: !SHEETMETAL ,gory (Cate -SHEETMETAL Permit# SM-2016-0045 PERMISSION IS HEREBY GRANTED TO: Project# JS-2016-001774 Est.Cost: $11,000.00 Contractor: License: Expires: Fee Charged:$25.00 BRIAN TATRO Sheetmetal- 11990 12/28/2016 ,Balance Due:$.0 0 Owner: AIMUA JOSEPH ,#of Fixtures ! - ;Applicant: BRIAN TATRO �IDigsafe# A T. 202 NORTH MAIN ST UseGroup ConstClass ISSUED ON: 18-May-2016 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: DUCTWORK FOR SFH THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2016-006638 17-May-16 219 $25.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck@northamptonma.gov GeoTMSO 2016 Des Lauriers Municipal Solutions,Inc. File# SM-2016-0045 APPLICANT/CONTACT PERSON BRIAN TATRO ADDRESS/PHONE 4 BERARD CIR (413)636-5840 PROPERTY LOCATION 202 NORTH MAIN ST MAP 16D PARCEL 004 001 ZONE URB(75)/URA(25) THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Buildinp,Permit Filled out Fee Paid Tyl2eof Construction: DUCTWORK FOR SFH New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 11990 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO MON PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding_ Special Pen-nit Variance* Received&Recorded at Registry of Deeds Proof Enclosed -Other Permits Required: -Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health -Permit from Conservation Commission Permit from CB Architecture Committee prmit from Elm Street Commission Permit DPW Storm Water Management Sfg�ntur �66&illdifn-I g ffieial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. IVER Commonwealth of Massachusetts { 0162016 City Of Northampton (� Sheet Metal Permit • Permit# (5�/�y" Estimated Job Cost: $ Permit Fee: $0? - Plans Submitted: YES NO Plans Reviewed: YES NO Business License# Applicant License# t ( 4 � O Business Information: Property Owner/rJob Location Information: Name: U �t��.,,, Name: -ToS 1 J Street: C-( L C^r-d C Street: A 0 1— rno r t, City/Town: S City/Town: V)O Telephone: —� 2 "-2 9C? Telephone l3 �" b u L� Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial/M-1-unrestricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family DC Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. iX- over 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work: Renovation: HVAC X Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: i �•, ecJ S - - Fees with Building Permit:$25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential, $100.00 Commercial INSURANCE COVERAGE: I have a current Iia insurance policy or its equivalent which meets the requirements of M.G.L. If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy fe Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER:I am aware that the licensee rings not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waive this requirement. Check One Only �- Owner`�-- Agent ❑ Signature of Owner or Owner's Agent By checking this box❑,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO progrPg4Z TngpPrfinnc Date Comments Fines PCfinn Data l nmmP.ntc Type of License: By ❑ Master Title ❑Master-Restricted City/Town ❑Journeyperson Signature of Licensee / Permit# ❑Journeyperson-Restricted ' °'( t Q License Number: l I Fee$ ❑ Check at ma-m macs gnv�I Inspector Signature of Permit Approval f Lot 1202 N. Main Street HVAC Load Calculations i for j Lot 1202 N. Main St Northampton Ma 4F `at'd i I 1 Prepared By: B.T. Brian Tatro Electrician Springfield Ma 413-782-2290 Thursday, March 31, 2016 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. i I I Pro of ct Report i� Project Title: Lot 1202 N. Main Street Designed By: B.T. Project Date: Wednesday, March 30, 2016 Client Address: Lot 1 202 N. Main St Client City: Northampton Ma Company Name: Brian Tatro Electrician Company Representative: B.T. i Company City: Springfield Ma Company Phone: 413-782-2290 w P - 3 Reference City: Westover AFB, Massachusetts Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 270 ft. Altitude Factor: 0.990 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 0 -0.65 80% n/a 70 n/a Summer: 92 71 36% 50% 73 20 Total Building Supply CFM: 1,281 CFM Per Square ft.: 0.553 Square ft. of Room Area: 2,318 Square ft. Per Ton: 748 Volume (ftp`)of Cond. Space: 19,583 Total Heating Required Including Ventilation Air: 46,632 Btuh 46.632 MBH Total Sensible Gain: 27,909 Btuh 91 % Total Latent Gain: 2,842 Btuh 9 % Total Cooling Required Including Ventilation Air: 30,751 Btuh 2.56 Tons(Based On Sensible+ Latent) 3.10 Tons (Based On 75% Sensible Capacity)NONE= MOM I I Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per RCCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i 1 I I I i C:\Program Files(x86)\Elite\Rhvacw\Projects\Tatro Electric Main St Northampton.rhv Thursday, March 31, 2016, 9:52 AM � Load-Pre- review Report Net Recl ft. Sen i Lat Net Sen i Min Min Sys Sys Sys �� Scope Toni Ton' /Ton Area Gain Gain Gain Lass 11 (( � � � "9' Clg� Htg� Clg� Act Size --------------_.w_._ ___,_.___ ..,__w_t, ...___._. .,______ .-----------------------, ._ CFMJ. CFM3 CFM CFMi CFM Building 2.56 3.10 748 2,318 27,909 2,842 30,751 46,632 612 1,281 612 1,281 1281 System 1 2.56 3.10 748 2,318 27,909 2,842 30,751 46,632 612 1281 612 1281 1,281 22x10 Duct latent 1,403 1,403 Zone 1 1,047 14,254 1,116 15,370 24,229 318 654 318 654 654 1410 10-Kitchen/Mud Hall/Half Bari 441 6,541 151 6,692 10,958 144 300 144 300 300 3-6 11-Dining Room 180 2,601 65 2,666 4,364 57 119 57 119 119 1-6 12-Family Room 426 5,111 900 6,011 8,907 117 235 117 235 235 2-6 Zone 2 1271 15,052 323 15,375 22,403 294 691 294 691 691 14x10 1-Cfte 91 1,166 28 1,194 1,841 24 54 24 54 54 1-5 2-Master Closet 120 296 0 296 340 4 14 4 14 14 1-5 3-Laundry Room 32 79 0 79 90 1 4 1 4 4 1-5 4-Bathroom(2nd Floor) 104 766 28 794 1,763 23 35 23 35 35 1-5 5-Bedroom(Front) 255 2,795 68 2,863 4,738 62 128 62 128 128 1-7 6-Bedroom(rear) 144 1,735 51 1,786 3,282 43 80 43 80 80 1-5 7-Walk In Closet 49 255 15 270 752 10 12 10 12 12 1-5 8-Master Bathroom 204 3,984 63 4,047 4,607 60 183 60 183 183 2-6 9-Master Bedroom 272 3,975 70 4,045 4,990 65 182 65 182 182 2-6 Sum of room airflows may be greater than system airflow because system has multiple zones. i I I C:\Program Files (x86)\Elite\Rhvacw\Projects\Tatro Electric Main St Northampton.rhv Thursday, March 31, 2016, 9:52 AM Total Budding Summary Loads MORON -Rig ' 1D-hw-o: Glazing-Double pane, operable window, heat- 197.4 7,875 0 8,375 8,375 absorbing, wood frame, u-value 0.57, SHGC 0.44 11 P: Door-Metal - Polyurethane Core 21 426 0 183 183 12F-Obw: Wall-Frame, R-21 insulation in 2 x 6 stud 2177.1 9,908 0 2,065 2,065 cavity, no board insulation, brick finish, wood studs 1613-38: Roof/Ceiling-Under Attic with Insulation on Attic 1270.5 2,311 0 1,784 1,784 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 19A-13p: Floor-Over enclosed unconditioned crawl 1046.5 3,485 0 947 947 space, No insulation on exposed walls, sealed or vented space, passive, R-13 blanket Subtotals for structure: 24,005 0 13,354 13,354 People: 4 800 920 1,720 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 16,691 1,403 12,667 14,070 Infiltration: Winter CFM: 78, Summer CFM: 47 5,936 639 968 1,607 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total Building Load Totals: 46,632 2,842 27,909 30,751 Total Building Supply CFM: 1,281 e 3CFM Per Square ft.. 0.�- M 553 Square ft. of Room Area: 2,318 Square ft. Per Ton: 748 Volume (ft')of Cond. Space: 19,583 777Total Heating Required Including Ventilation Air: 46,632 Btuh 46.632 MBH Total Sensible Gain: 27,909 Btuh 91 % Total Latent Gain: 2,842 Btuh 9 % Total Cooling Required Including Ventilation Air: 30,751 Btuh 2.56 Tons (Based On Sensible+ Latent) 3.10 Tons (Based On 75% Sensible y( Capacity) miff Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads accordingto the manufacturer's performance data a p t your design conditions. I C:\Program Files (x86)\Elite\Rhvacw\Projects\Tatro Electric Main St Northampton.rhv Thursday, March 31, 2016, 9:52 AM I System 9 Summary Loads j aen dotal I 1D-hw-o: Glazing-Double pane, operable window, heat- 197.4 7,875 0 �8,375� 8,375 absorbing, wood frame, u-value 0.57, SHGC 0.44 11 P: Door-Metal - Polyurethane Core 21 426 0 183 183 12F-Obw: Wall-Frame, R-21 insulation in 2 x 6 stud 2177.1 9,908 0 2,065 2,065 cavity, no board insulation, brick finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1270.5 2,311 0 1,784 1,784 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 19A-13p: Floor-Over enclosed unconditioned crawl 1046.5 3,485 0 947 947 i space, No insulation on exposed walls, sealed or vented space, passive, R-13 blanket Subtotals for structure: 24,005 0 13,354 13,354 People: 4 800 920 1,720 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 16,691 1,403 12,667 14,070 Infiltration: Winter CFM: 78, Summer CFM: 47 5,936 639 968 1,607 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 System 1 Load Totals: 46,632 2,842 27,909 30,751 j w Supply CFM: 1,281 CFM Per Square ft.: 0.553 Square ft. of Room Area: 2,318 Square ft. Per Ton: 748 Volume (ft')of Cond. Space: 19,583 Total Heating Required Including Ventilation Air: 46,632 Btuh 46.632 MBH Total Sensible Gain: 27,909 Btuh 91 % Total Latent Gain: 2,842 Btuh 9 % Total Cooling Required Including Ventilation Air: 30,751 Btuh 2.56 Tons (Based On Sensible + Latent) 3.10 Tons (Based On 75% Sensible Capacity) Rhvac is an ACCA approved Manual J and Manual D computer program. j Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. 1 I i i C:\Program Files (x86)\Elite\Rhvacw\Projects\Tatro Electric Main St Northampton.rhv Thursday, March 31, 2016, 9:52 AM System 1 Room Load Summary AU k Illffigma- I ---Zone 1--- 10 Kitchen/ Mud Hall/ 441 10,958 144 3-6 510 6,541 151 300 300 Half Bath 11 Dining Room 180 4,364 57 1-6 608 2,601 65 119 119 12 Family Room 426 8,907 117 2-6 597 5,111 900 235 235 Zone 1 subtotal 1,047 24,229 318 14,254 1,116 654 654 ---Zone 2--- 1 Office 91 1,841 24 1-5 393 1,166 28 54 54 2 Master Closet 120 340 4 1-5 100 296 0 14 14 3 Laundry Room 32 90 1 1-5 27 79 0 4 4 4 Bathroom (2nd 104 1,763 23 1-5 258 766 28 35 35 Floor) 5 Bedroom (Front) 255 4,738 62 1-7 480 2,795 68 128 128 6 Bedroom (rear) 144 3,282 43 1-5 584 1,735 51 80 80 7 Walk In Closet 49 752 10 1-5 86 255 15 12 12 8 Master Bathroom 204 4,607 60 2-6 466 3,984 63 183 183 9 Master Bedroom 272 4,990 65 2-6 465 3,975 70 182 182 Zone 2 subtotal 1,271 22,403 294 15,052 323 691 691 Duct Latent 1,403 i System 1 total 2,318 46,632 612 27,909 2,842 1,281 1,281 System 1 Main Trunk Size: 22x10 in. Velocity: 838 ft./min Loss per 100 ft.: 0.104 in.wg Note: Since the system is multizone, the Peak Fenestration Gain Procedure was used to determine glass sensible gains at the room and zone levels, so the sums of the zone sensible gains and airflows for cooling shown above are not intended to equal the totals at the system level. Room and zone sensible gains and cooling CFM values are for the hour in which the glass sensible gain for the zone is at its peak. Sensible gains at the system level are based on the"Average Load Procedure+ Excursion" method. d 6 m Net Required: 2.56 91%/9% 27,909 2,842 30,751 Recommended: 3.10 75%/25% 27,909 9,303 37,212 I sx, -�� .y`� „r�` - _ �&"moi a�" Heating System ,u Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER j Sound: Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh C:\Program Files (x86)\Elite\Rhvacw\Projects\Tatro Electric Main St Northampton.rhv Thursday, March 31, 2016, 9:52 AM 12' DECK 11_5,x 9'-9" 42'44'-b 15'-2" 4" 5'-2" 17'-911 31711 6111 21611 b.-4" 0 m 6 6 - GFCII FCI / FCI m 30 ((1 K Ste✓ HARDWQ D FLOOR w CE I TILE FLOOR \ \ A z GFC11}� �KITGHEN / 20'-T x 14'-2" iY (L cFcl 3 - 14 / NI G �r 20'-9" o C / 14'- 11'-8" 0 O y_Y 11668 - U_ 41'-1 : itLo _ ~ 4-9' b" Pantry 4' v x in - 21611 :o cnLV TILE FLOOR I in Cu t - (V x - m sQ N 2868 1 � It m O I CL c E Ho FAM Y F MIL to z N / 31 811 16,_q„x '-11" :p O \ HARmoo FLOOR aN u p z n 4ARAGE �— w �0'-0"x 22'-6" �\ - O UP 2-b m a d _ ISo 17'-7" a in \ I i —1 C 1 TILE FLOOR fu a) < U Q o I o v) o � aloez I a Ci6� o C rn I I20'-6"x4'-1 PD G _Z fu co Q V w\ 20'b"x 4'1 0 50 e v I I -5 0 0—, Elv- 161 121. 1 DATE: /�eTU r ^ 5-0C�v� 2/3/2016 (,(�J SCALE: 2'-6" 16' 2'-6" 12'-5" 2' b'-7" 21'11 NG AREA 103 s ft 21 SHEEP: 44'-6" A—2 42' 14 19 4' z 0 z :0 3,_ „ 3.5.. o r 12' 30 d z Walkin Gloset T-r T.a- z MASTER BDRM � _ J 15'-11"x o it 16' BEDR D/ v v 12'12'-1 ' r O :o 2' v O r 430w ICE vQ i'-"1-2"_2„ ICEz O B 2666 2466 v � w 1 H iV 113" 1 �m m p5 TBATK -( T'- � cno in in .o m °? - - iv fu c in0. 40 O a er#set 0 Q X66= DN in z d. N lu :0 2'-b" ?1, 0" o N 2'-4" o C, / 2'-4� o r, z 4'-8" CE w '-6"7'4 2-10" �` O o � qa q'-4" BEDROO - / 13'-b"x 14'-1 2%8 U TER BATH 0,-e.,x 13'-0^ 3'-2' r u, in oC a� o o w OFFICE U a t9� �W� 12,10,.x b,1,, b'9" o vo 0 i `o 5c) 0 Q D `n a C6c'no 4. CO r-, 6-7" 6'-10" 2 LIVING AREA DATE: C, c v 11'-2" 13'-3" 1364 sa ft3'-3" 14'-4" 2/3/2016 42' SCALE: SHEET: 2nd Floor A-3 44'-2" 22'-10" 44'-2" 21'-4" 25'-b" 16'-10" 20'-8" - — — — — - - -- - — r- - - - - - - - - - - - r - - - - - - - - - - - � 16'-b" 2x12 joists 12"OC\ ( I S r I t' I D y I I i1 I o s' I� 2x12 joists 12"OC I 2x12 joists 12"OC I / w L- - - - - - - - - - - - - - -4 - - - - - - - - -- - 5' 52'-8" % 3' 40'-8" pD DRAWINGS PROVIDED BY: PROJECT LOCATION SHEET TITLE: NO. DESCRIPTION BY DATE I N rn 7oslad & Associates, P.C. LOT 1 202 N. Main Street N Mo 83 superior Avenue FOUNDATION PLAN O Indian Orchard, MA 01151 Northampton, MA