Loading...
32C-281 (10) 100 WILLIAMS ST BP-2016-1338 GIs #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 32C-281 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:woodstove BUILDING PERMIT Permit# BP-2016-1338 Project# JS-2016-002304 Est. Cost: $2800.00 Fee: $40.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: BERNARDSTON FARMERS SUPPLY 99401 Lot Size(sq.ft.): 5532.12 Owner: MALZONE WESLEY Zoning. URC(100)/ Applicant: BERNARPSTON FARMERS SUPPLY AT. 100 WILLIAMS 'ST Applicant Address: Phone: Insurance: 43 RIVER ST (413) 648-9311 O WC BERNARDSTONMA01337 ISSUED ON.•5/17/2016 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL PACIFIC ENERGY - NEO 1.6 WOODSTOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W.', Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 5/17/2016 0:00:00 $40.00 212 Main Street,Phone(413)58117-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner _ JD of Northampton RECEIVED Massachusetts s r Massachlusetts I` ' NT OF BUIT`DING INSPECTIONS �. r 3 f� Street •�/1► N�unicipal Buildingorthampton,' MA 01060OEp�OF BM WNOINV NORTFb1MPTQtLMA SINGLE OR TWO FAMILY SOLID FUEL APPLIANCE PERMIT APPLICATION FOR WOOD, COAL, PELLET, CORN,STRAW OR SIMILAR STOVES, OR FIREPLACES Check# 11 66 Please fill in all appropriate information 1. Name of Applicant : 6c fir" )410(7/1 J Address: 106 OX_A �Z'o — 00 tyl A44 a'073;" Telephone: 377-3114� 2. Owner of Property : �� JQleorm Address: /OO ��i`//i�"MS 'Sy- X/69KttvP/erg &0W Telephone: 3�6177g6'- 3. Status of Applicant : Owner Contractor i 4. Type or Brand of Stove T 5. Estimated Cost : ,1(?00, If applicant is not the homeowner::-. Contractor name_`l�)aU�?los / 4b� Construction Supervisor's License Number Expiration Date /—6 LUQ Home Improvement Contractor Registration Number Expiration Date All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit 6. Certification: I hearby certify that the information contained herein is true and accurate to the best of my knowledge. I DATE: `�-pAPPLICANT'S SIGNATURE DATE: HOMEOWNER'S SIGNATURE APPROVED DATE: BUILDING OFFICIAL �.-,t. ,.>.,�.,. �.. _ .� �x. ,�. t .�. �...,. ?ze 4,©ilzr'1 onive[dGi:/1 Oj lllassacizziselts Deparment of Industrial a ecidents -ce of hzvestig gdons 7'.=' f pct?��•ess Street ;'fe 700 Boston, MA 021 -2017 ` = W-,vw.nzas5'_govIdia %crke 1_c`M_eRsaLh_ a 1 ,sL;i_,ce AffidW�t: Builders/Cfl?traetors[Electridansp,lumbers PPEcant Information Tease Print i!leg bf . Name (Business/OrRaatioflpdi�6dual;. AFS d/b/a THE FIRE PLACE � r Address- '06 STATE ROAD i,., i 7 i LY_ MA 01093Phone x.413-397-3463 an errplo�rer? Chedrthe appropriate box: Type of project(required): __ _ i 0 -'_ [( 1 am a general contractor and i i = - ;i�_��-;, i, 6_ ❑Neiv construction r_ ill a Le/or pais tinge}. have hired the sub-contractors so.ie pL_eta or pay tner- listed an the attached sheer_ 7- ❑Remodeling no enmlo,zes These sub-contractors bare 8. ❑Demolition :•cr._;-� nor Te in any capacity_ employees and bare workers- comp_ insurance comp.insurance.= 9 El Building addition 3_ jj""-''1'� Vire are a corporation and its 10.❑Electrical repairs or additi I Ll p t_OIIS _ am a lioplaeowner doing all work officers have ever [sed their 11.❑Plu ibing repairs or additions � rsefF FNo workers' comonight ight of exemption per tNAGL A] c_ 152,§t(-.),and =�e have no 7-❑ Roof repairs _i1SLt'�lCe rCgllire. .] ; employees_ [No vvorke& 13-❑ Other comp-insrrance required] appl i cant Char checks box=1 mut also tip out me section below showing their wortkers`compensation Dolicy information- i omeowner �.aho submir ibis a�fidavit indicatin!_Chep are doing all work-and then hire outside contractor must submit a new,amda%itindicatiII!-:sec:,. = Floor ProtectorCombustion Air The stove may be installed on a combustible floor provided Intake or combustion air can be supplied to the stove in one noncombustible ember protection is used. of two ways. Consult your local building code or CAN/CSA- This protection must extend as follows: B365,Installation Code for Solid-Fuel-BurningAppliancesand Equipment before proceeding.The unit must have adequate In Canada: 18" (457 mm)on the firing side and 8"(203 mm) air for combustion provided in the room the unit is installed in. to the other sides. See Figure#4, below. 1. Outside air supply-(Necessary for mobile home instal- lation, optional for residential installation.) Outside air may be drawn from either underneath the stove or from behind. FIG.#4 Canada Only Non-combustible To draw outside air through the floor,leave the 4"(102mm) floor protector knockout or cover late in la Minimum Width-43 1/8'(1.1 m) p place in the rear of the ash box Minimum Overall Depth-45 5/8"(1.16m) / enclosure. 8" [203mm] Cut or drill a 4"(102mm)diameter hole directly below the bottom hole of the ash box enclosure. Connect enclosure to the floor with a short 4"(102mm) diameter pipe. If you wish to connect the outside air to the rear hole on the ash 0 T box,then remove the 4"(102mm) knockout or cover plate °Dat the rear of the ash box. E F5 N This hole must get its air from a ventilated crawl space 3F0 @ @ `� or be extended with duct to the outdoors(see Figure#8,o 0 -o Page 13).The use of outside combustion airfor residential installation requires the unit to be secured to the structure to prevent dislodging of the air duct. 18" [457mm] To draw outside air from behind the stove, an outside air adaptor may be required (see Optional Blower section). Cut or drill a 4"(102mm) hole through a wall behind the unit. Use an appropriate household 4"(102mm) inlet. In USA: 16" (406 mm) to the front and 8" (203 mm) to the Note: This unit is not designed to be operated with the firing sides of the fuel loading door opening. See Figure#5,below. door open. In addition to the obvious hazard of sparks This protection is also required under the chimney connector landing on combustibles, an open fire door will cause and 2"(51 mm)beyond each side when using horizontal pipe. the heater to draw air from the living space and possibly cause suffocation. FIG.#52. Room air supply- Remove the cover plate or knockout U.S.A. Only from the rear of the ash box enclosure. The stove will Minimum Width-33 3/8°(848mm) now draw its air from the room through this opening and Minimum Overall Depth-32 3/4"(832mm) into the firebox intake. No -combustible Note: The living space around the heater must be well floor protector ventilated with good air circulation. Anything that may 0 cause a negative pressure can cause gases or fumes to be pulled into the living area. During extremely cold weather,and especially when burning at very slow rates, the upper parts of the exposed chimney may ice up, 0 8 0 @ partially blocking the flue gases. If blockage occurs,flue gases may enter living space. CX, E Note:An abfja' S^outside air pipe shield is ShS['STWo place No 16" [406mm] E [ Xb' f aXthe 4"pipe used to bring outaide air into the unit. 3 N efc"a- e for instalaltion are provided i [fZ fZWeZ[Wdz 1 00 (Part#N E 16.7872) NEO 1.6 "' 0&16-24 EPAIFNER C OPACIFIC ENERGY FIREPLACE 9 PRODUCTS LTD. Residential Warning:Under no circumstances is this heaterto be installed Chimney and Connector in a makeshift or "temporary" manner. It may be fired only after the following conditions have been met. Connect to a listed chimney or a chimney suitable for use with solid fuel that is lined and in good condition and meets * DO NOT ATTEMPT TO CONNECT THIS HEATER TO local building codes. The chimney flue size should be the ANY AIR DISTRIBUTION DUCT. same as the stove outlet for optimal performance. Reduc- ing or increasing the flue size may adversely affect stove * Outside combustion air or fresh air into the room may be performance. Chimney flue exit is to be 3 feet (1 m.) above required in your area, consult local building codes (see roof and two feet(0.6 m.)above highest projection within 10 Combustion Air section). feet(3 m.).The installation must meet all local codes.Do not connect this unit to a chimney flue serving another appliance. -The services of a competent or certified installer, (certified Minimum system height is 15 feet (4.6 m.) (measured from by the Wood Energy Technical Training program(WETT)-in base of appliance). Canada,Hearth Education Foundation(HEARTH)-in U.S.A.,) are strongly recommended. Double-Wall Connector BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO: IN CANADA- ULC S-641 LISTED CONNEC- - Use a listed double-wall connector. TOR AND ULC-S-629 LISTED CHIMNEY,IN USA- UL-103 - Install all components to the chimney connector manu- HT LISTED CONNECTOR AND CHIMNEY facturer's installation requirements. Single-Wall Connector Clearances Smoke pipe must be: * as short and straight as possible, use six inch 1. This heater may be installed using a single-wall connector diameter, 24 gauge black pipe that is clean and in new (smoke pipe)or listed double-wall connector(see Mobile condition. Home installation). * secured at every joint and collar with 3 sheet metal screws. 2. Clearances to combustible surfaces and materials using installed with the crimped or male ends pointing down. single-wall connector are shown in Figure#7, page 12. This will carry any liquid creosote or condensation back Clearances may be reduced with various heat insulating into the stove. materials.Consult local fire codes and authorities for ap- * The chimney connector shall notpassthrough an attic,roof proval_ space,closet or similar concealed space,floor,or ceiling. 3. Alternately,for close clearances, use a listed double-wall Where passage through a wall,or partition of combustible connector. See Fig #6, page 12. material is desired,the installation shall conform to CAN/ CSA-6365,Installation Code for Solid-Fuel-Burning Appli- It is possible to store wood between the stove supports, un- ances and Equipment or in the U.S.,NFPA 211:Standard derneath the unit.The wood must not extend further forward for Chimneys, Fireplaces,Vents, and Solid Fuel-Burning than flush with the supports.Do not store paper or othe stove Appliances. lighting devices within the pedestal area.Although this is pos- sible it is not recommended.NOTE:Refer to local fire codes, procedure CAN-13365 and NFPA 211 in the U.S.. WARNING:IFYOU CHOOSETO STORE WOOD BENEATH 1. If a listed chimney and double-wall connector is to be YOUR UNIT,EXERCISE EXTREME CAUTION WHEN LOAD- connected to the stove,install all components to the chim- ney manufacturer's installation requirements. (Outside ING THE WOODSTOVE. EMBERS CAN FALL AND MAY ', combustion air may be required, consult local building IGNITE WOOD BENEATH STOVE. codes. See Combustion Air section on page 10.) 2. If it is desirable to use smoke pipe in conjunction with the insulated chimney, see step 4. 3. If a roof or ceiling support is used in the installation, you will find the chimney manufacturer's complete instructions packed with the roof support. 4. To start installing smoke pipe (chimney connector), slip crimped edge of the pipe inside the stove collar. Use holes provided in collar to secure pipe with three screws. 5. Install the remaining lengths of pipe one on top of the other to the finished height of the chimney connector and secure to each other. 10 ENER NEO 1.6 " "&#(2$& FIG.#6 Single Wall Connector- Residential 18" 12" Residential 8" 8" 457mm 305mm203mm Minimum 20" 508mm 251/2" — Clearance to % polio 673mm % % Combustibles 2038m" m �j ", Double Wall Connector- Residential ill, 5" ill, 5" 279,mm 127mm 2791mm 127mm 15" 3" 8" rn 8" 76mm 03MI 8" 203mry 203mrr 21 1/2 T '-' 2 1 Cl 2—" 9mm 549mm Alcove: Min.H:eight 7' 3" Max. epth 3' Mobile Home Installation i Warning:Under no circumstances isthis heaterto be installed Clearances in a makeshift or "temporary" manner. It may be fired only after the following conditions have been met. This heater must be installed with a listed double-wall con- nector and compatible chimney system. - DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Clearances to combustible surfaces and materials are shown- DO NOT INSTALL IN A SLEEPING ROOM. in Figure#7 below.Clearances maybe reduced with various heat insulating ma- -BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE terials.Consult local fire codes and authorities for approval. LISTED TO: IN CANADA- ULC 5-641 LISTED CONNEC- TOR AND ULC-S-629 LISTED CHIMNEY, NOTE: Longer chimney lengths and different pitch flashings IN USA - UL-103 HT LISTED CONNECTOR may be used. All other parts listed must be installed (see AND CHIMNEY Figure#8, Page 13). Install all components to the connector or chimney manufacturer's installation requirements.Consult -Outside air supply must be used for Mobile Home installa- your chimney supplier for installation advice. tions see Figure #8, Page 13. - Remove the chimney down to the roof flashing to allow for transportation of the mobile home. FIG.#7 Double Wall Connector- Mobile Home lift 511 2797m 127mm Mobile Home Minimum 31' 811 1511 — Clearance to 76mm 203mr Combustibles 381 m ®% % 21 1/2" 31' % 549mm 76mm NEO 1.6 0&16-24 PACI ENER ©PACIFIC ENERGY FIREPLACE 11 PRODUCTS LTD.