Loading...
31C-024 (2) 61 FORD CROSSING SM-2016-0041 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON IGIS#: 12118 Map: 31C °24 Lot: SJIEETMETAL PERMIT Lot: ' Permit: SHEETMETAL Category: ,SHEETMETAL - - - Permit# SM-2016-00411 _ Project# JS-2216-0014PERMISSION IS HEREBY GRANTED TO: Est. Cost: $6,000.00 Contractor: License: Expires: Fee Charged:$25.00 RICHIES AIR CONDITIONING& Sheetmetal-531 03/15/2016 Balance Due:$.00 Owner: KENT PECOY&SONS CONSTRUCTION INC W- --- - — _ #of Fixtures Applicant: RICHIES AIR CONDITIONING&HEATING INC DigSafe# AT: 61 FORD CROSSING juseGroup { L&olistClass< y ISSUED ON.- 03-May-2016 AMENDED ON: EXPIRES ON. TO PERFORM THE FOLLOWING WORK: DUCTWORK FOR SFH THIS PERMIT MAY BE REVOKED BY THE CITY,OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Laid: Check No: Amount: Sheetmetal REC-2016-006385 03-M y-16 17472 $25.00 212 Main Street,Phone:(413)587-1240,Fax:(413)581-1272,Email:Ihasbrouckgnorthamptonma.gov GeoTMSO 2016 Des Lauriers Municipal Solutions,Inc. File#SM-2016-0041 APPLICANT/CONTACT PERSON RICHIES AIR CONDITIONING&HEATING INC ADDRESS/PHONE P O BOX 407 (413)789-1244 Q PROPERTY LOCATION 61 FORD CROSSING MAP 3 1 C PARCEL 024 ZONE PV THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATIO CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Al Ii Fee Paid Building Permit Filled out It Fee Paid Typeof Construction: DUCTWORK FOR SFH LIN C/ V New Construction Non Structural interior renovations Addition to Existing Accesso Structure Building Plans Included: Owner/Statement or License 531 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON TRIS APPLICATION BASED ON INFO ION PRESENTED: pproved Additional permits required(see belo`v) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project : Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR _Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit fro Street Commission Permit DPW Storm Water Management cJ /6 Sign Bui in OffliAf Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board o Health,Conservation Commission,Department of public works and other applicable permit granting autho ities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. t _.. Commonwealth of Massachusetts MAY - 2 2016 Sheet Mc tal Permit DEPT.OF iLDIN GINS ISIS NOM PJ' Permit# CPl Estimated Job Cost Permit Fee: $`� 7 Plans Submitted: YES NO Plans Reviewed: YES NO Business License# C Applicant License # � Business Information: Property Owner/Job Location Information: a _ Name: \G�1 ��G'G -��'�G- Name: tQ& \ ,=Mt — Street: Q© LAIZ'q Street: q:a 'Poo CAc-.ILO City/Town: f1�Pw�� � MPP I City/Town: , Telephone: LA 13 `l$ k ak'Ll Telephone: Li Q `'fig�"�CP'$ Photo I.D. required/Copy of Photo I.D. attached: YES NO Building Type: Residential: 1-2 family i/"' Multi-family Condo/Townhouses Commercial: Office Retail Industrial Educational Institutional Building Cubic Footage: under 35,000 cu. ft. over 35,000 cu. ft. Sheet metal work to be completed: New Wor : Renovation: HVAC ✓ Metal Roofing Kitchen E aust System✓ Chimney/Vents Provide brief description of work to be done: V:�kbA\G4'tC ft t D SO4wvv .,- S T Mc-%L 4w3txR1(- Pzk 1 Ag1kC- tx-cv--AIE�A FAA T- 12MI4 FAv4 Atp. pReZo Au-R UermLA-mA 4 Rye \, rV- INSURANCE COVERAGE: 1 have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yesio/No❑ If you have checked Yes,indicate the type of coverage by checking the appropriate box below: A liability insurance policy A Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Progress Inspections Date Comments Final Inspection Date Comments Type of License: By 0 Master Title ❑ Master-Restricted City/Town ❑Journeyperson Signature of Licensee Permit# ❑Journeyperson-Restricted CJ. � Fee$ License Number: ❑ Check at www.mass.gov/dpl Inspector Signature of Permit Approval ® a ��,4l&Thls combination qualifies for a Federal Energy I , Efficiency Tax Credit when placed in service www.ahridirectory..org between Feb 17,2009 and Dec 31,2016. Certificate of Product Ratings AHRI Certified Reference Number: 5865024 Date: 1/21/2016 Product: Split System: Air-Cooled Condensing Unit, Coll with Blower Outdoor Unit Model Number:4TTR6024B1 Indoor Unit Model Number:4TXCB025BC3 Furnace Model Number:*UH2B060A9V3 Manufacturer:TRANE Trade/Brand name: TRANE Region:All(AK,AL,AR,AZ, CA,CO,CT, DC,DE, FL, G4A,HI,ID, IL,IA, IN, KS,KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK,OR, PA,RI, SC, SD,TN,TX, UT,VA,VT,WA,WV,WI,WY,U.S.Territories) Region Note: Central air conditioners manufactured pr r to January 1,2015,are eligible to be Installed in all regions until June 30,2016. Beginning my 1,2016,central air conditioners can only be installed in region(s)for which they meet tl ie regional efficiency requirement. Series name:XR16 Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 21 /240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of ra ng accuracy by AHRI-sponsored, independent,third party testing: I I Cooling Capacity(Btuh): 20600 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 16.00 IEER Rating(Cooling): i Ratings followed by an asterisk(")indicate a voluntary rerate of previously published data, nless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER Ti AHRI does not endorse the product(s)listed on this Certificate and makes no repres tations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for dam es of any kind arising out of the use or performance of the producijs),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid on y for models and configurations listed in the directory at www.ahridirectory.org. I TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI.This Certificate sh0l only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or)n part,be reproduced;copied;disseminated; entereg Into a computer database;or otherwise utilized,In any form or manner or bylany means,except for the user's Individual, personal and confidential reference. AIR-CONDMONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahridlr�ctury.org,click on"Verify Certificate'link uY make life hatter'" and enter the AHRI Certified Reference Number and the date on which the certificatq was issued, which is listed above,and the Certificate No.,which is listed at bottom right. - ©2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130978842021255943 + wrightsoft Load Short Form Date: Entire House By: RICHIE RICHIE'S AIR CONDITIONI�G & HEATING 81 Industrial Lane,Agawam,Ma For: THE PECOY COMPANY 61 FORD CROSSING, NORTHAMPTON, MA Htg Cig Infiltration Outside db (°F) 0 87 Method Simplified Inside db('F) 70 75 Construction quality Best Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference (gr/Ib) 28 24 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1110 cfm Actual air flow 1110 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.96 ROOM NAME Area Htg load Cig load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) SECOND FLOOR p 1114 27045 9241 530 494 FIRST FLOOR p 1154 20582 13047 580 698 Entire House d 2268 50627 20758 1110 1110 Other equip loads 0 0 Equip. @ 0.92 RSM 19097 Latent cooling 977 TOTALS 1 2268 1 56627 1 20074 I 1110 1 1110 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2016-Apr-2613:03:40 WCI hCSOft Right-Suite®universal 2012 12.0.11 RSU173113 Page 1 C:\Users\wbean\Desktop\LOADS\RICHIE'S PECOY 61 FORD CROSSING.rup C�Ic=MJ7 Front Door faces: Job:Load Short Form + wrightsoft Date: FIRST FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma For: THE PECOY COMPANY 61 FORD CROSSING, NORTHAMPTON, MA Htg Clg Infiltration Outside db (°F) 0 87 'Method Simplified Inside db(°F) 70 75 Construction quality Best Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 28 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load) Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) KITCHEN/DINING 416 10344 4831 203 258 FAMILY ROOM 272 $710 1638 112 88 BATH 150 585 536 51 29 FOYER 160 0710 2988 112 160 DEN 156 5233 3054 103 163 FIRST FLOOR p 1154 20582 13047 580 698 Other equip loads 0 0 Equip. @ 0.92 RSM 12003 Latent cooling 539 TOTALS I 1154 t 20582 1 12542 I 580 1 698 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. `-'�} Wrt (1tS�ft g 2016-Apr-2613:03:40 {' Ri ht-Suite®Universal 201212.0.11 RSU1731,3 Page C:\Users\wbean\Desktop\LOADS\RICHIE'S PECOY 61 FORD CROSSING.rup G41c=MJ7 Front Door faces: +I+ wrightsoft Load Short Form Job: j Date: SECOND FLOOR By: RicHiE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma For: THE PECOY COMPANY 61 FORD CROSSING, NORTHAMPTON, MA Htg Clg Infiltration Outside db (°F) 0 87 (Method Simplified Ins ide db('F) 70 75 ,Construction quality Best Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/Ib) 28 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency , n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load', Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) MASTER BED 442 1,1156 4151 219 222 MASTER BATH 121 2238 446 44 24 BED 2 143 4181 1470 82 79 BATH 2 80 2329 921 46 49 HALL 160 $339 171 46 9 BED 3 168 44803 2083 94 111 SECOND FLOOR p 1114 21045 9241 530 494 Other equip loads 0 0 Equip. @ 0.92 RSM 8502 Latent cooling 438 TOTALS I 1114 1 21045 1 8940 1 530 1 494 Calculations approved by ACCA to nheet all requirements of Manual J 7th Ed. Wrt htSoft2016-Apr-2613:03:40 Right-Suite®Universa1201212.0.11 RSU1731(3 C:\Users\wbean\Desktop\LOADS\RICHIE'S PECOY 61 FORD CROSSING.rup C4c=MJ7 Front Door faces: Page i