Loading...
29-516 (4) 26 TARA CIR BP-2016-1257 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 29-516 (CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Cateeory: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-1257 Project# JS-2016-002161 Est. Cost: $6000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq. ft.): 8886.24 Owner: SCHMITH DONNA M Zonin : Applicant: SOLARCI'TY CORP AT. 26 TARA CIR Applicant Address: Phone: Insurance: 604 SILVER ST (978` 215-2369 O Workers Compensation AGAWAMMA01001 ISSUED ON.•4/29/201I6 0:00:DO TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 2.08 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.Wo Building Inspector Underground: Service: Meter:', Footings: Rough: Rough: House ft Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sivature• FeeType• Date Paid: Amount: Building 4/29/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2016-1257 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (978)215-2369 Q PROPERTY LOCATION 26 TARA CIR MAP 29 PARCEL 516 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATIOIN CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: INSTALL ROOF MOUNTELAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON T141S APPLICATION BASED ON INOORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission 'Permit DPW Storm Water Management Demolition Delay rx9 fVp / Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicajnt's burden to comply with all zoning requirements and obtain all required permits from Board o:'Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. • Department use only t ,City Northampton - �13t'ildi Department Curbr sit C 12 pin Street Sewe.rlv�# ty R m 100 WaterlWell Mai North,�mp n, MA 01060 'TWO Sets of Sin. uf4l-'Pl6ns 0 Fax 413-587-1272F'IpV$Jte Flans QED"�y�1HP;ws�;cr.,` fi��S epi AP CATION TO CONSTRUCT,ALTER,REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address: 26 Tara Cir Map Lot unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Donna Schmith 26 Tara Cir,Northampton MA 01062 Name(Print) Current Mailing Address: 413-522-9223 Telephone Signature 2.2 Authorized Agent: SolarCity CorpNictoria Junc 604 Silver St Agawam MA 01001 Nam (Pr Current Mailing Address: 978-215-2367 gna re Telephone "SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 2,000 (a)Building Permit Fee 2. Electrical 4,000 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total= 0 +2+3+4+5) 6,000 Check Number 7 r 4 This Section For Official Use Only Building Permit Number: [date Issued: Signature: Building Commissioner/Inspector of Buildings Date �r __ AL Section 4. ZONING AU Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [', ] Decks [ ] Siding[ ] Other❑✓ Brief Description of Proposed Work: Install solar electric panels to roof of existing home,to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes _No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing,Jomplete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. MaSscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Donna SChmith as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 04/26/2016 Signature of Owner Date 1, SOLARCITY CORPNICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORPNICTORIA JUNCK Print Name,--, — . C 04/26/2016 Sik,jurener/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Addres Expiration Date 978-875-1698 Signature Telephone 5.Registered Home Improvement Contractor: Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2017 Address Expiration Date elephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,You may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature r Tl Commonwea The fh Massachusetts N of +t Department of IodusrrialAccidents tk N, Office Office Of Investigations l , s 1 Congress Preet,Suite 100 7 Boston,MA 02114-2017 <�.a:a �• www mgss.gouldiia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers Applicant In rm tion Please Print Le iibl Name(Business/0rganizationiindividual): SOLARCITY CORP Address:3055 CLEARVIEW WAY City/State/Zi :SAN MATEO,CA 94402 Phone#:888-765-2489 Are you an employer?Check the appropriate box. Type of project(required): 1.® 1 am a employer with 5000 4. ❑ 1 am a genjeral contractor and 1 6. ❑New construction employees(full and/or pail-time), have hired the sub-contractors 2.❑ 1 am a sole proprietor or partner- listed on a attached sheet. 7. Remodeling ship and have no employees These sub+contractors have S. ]Demolition workingfor me in an capacity. employees and have workers' Y9. ❑Building addition [No workers'comp.insurance comp.insurance.= re uired. 5_ ❑ We are a corporation and its 14.❑Electrical repairs or additions 3.0 q ] officers have exercised their I IQ Plumbing repairs or additions 1 arts a homeowner doing all work myself: [No workers' comp. right of exemption per MGL 12-❑Roof repairs insurance required.]t c. 152,§l(4),and we have no SOLAR 1 PV employee$.[No workers' 13.E Other cotnp.ins ranee required.] "Any sppagant that clicebx box#1 must also fill out the section bcto►v sho►via (heir workers'compensation policy inforstation. t 1-torneowners who submit this affidavit indicating they are doing all work anti Then hire outside c011110c1ors muse submit a new affidavit indicating such. tConifactors that check this box must attachcd an additional sheet showing tltq name of the sob-contractors and state whether or not those entities have employees. irthesub-contractors havo omployecs,they must provide their workers'comp.policy number, I trio an ensptoyer float is providing workers'conspensadon i►rkcurmrce for orry employees. Below is the policy anrdJoh site information. Insarance Company Name: Zurich American Insurance Company Policy it or Self-ins.Lie. n:_WC0182014-00 _ Expiration hate: 09/01/2016 Job Site Address: ��1 a City/Statelzip: /►"r rT Attach a copy of lite workers'compensation policy declaration page(showing the policy at In[ser and expiratia date). 7 7 Failure to secure coverage as required under Section 25A of MGL e. 152 can lead to tite imposition of critrtinal penalties of a (G fine up to$1,500.00 and/or one-year imprisonment,as well as'eivil penalties in the form of a STOP WORK ORDER and a fine of up to$254.00 a day against the violator. Be advised that a copy of this statement muy be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify ander she pains and perraGies of perJrrry 1y4al Noe hirarmafiarr providedabove is true and correct. Cbo! G�-�lXl w Phone tt- 1 Official rise only. Do nol write in This area,to he completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): i.hoard of Health 2.Building Department 3.City/TovYn Clerk 4.Electrical Inspector S.Plumbing Inspector 6.Other Contact Person• - Phone#- ® BATE 4MMMONYYYI. 1 A�!�a CERTIFICATE OF LIABILITY INSURANCE 8811712095 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCERTACT MARSH RISK&INSURANCE SERVICES -4NS'' T. 345 CALIFORNIA STREET,SUITE 1300 PW Itp Eat)L 1 . . __ . _ Ai Ns1..... CALIFORNIA LICENSE NO.0437153 EMAIL SAN FRANCISCO,CA 94104 SSS'— Attn:Shannon Scott 415.743.8334 tNSURE1S)AFFORDING COVERAGE 998301-STND-GAWUE-16-16 INSURER A:Zurich American insurance Company 16535 INSURED -. ......._.. ..-NIA ..... .... ... ._ .. NIA SolarCity Corporation INSURER B 3055 Cfealview Way INSURER c NIA NIA San Mateo,CA 94402 INSURER D:American Zurich Insurance Company 40142_ INSURERE... �.. ..... INSURER F: COVERAGES CERTIFICATE NUMBER: SFA-002713836-08 REVISION NUMSER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR AOPl.9UBR..... . POLICY TYPEOFiNSURANCE POLICY NUMBER VdODIYYYY)IMMIOONYYYI LIMITS A X COMMERCIAL GENERAL LIABILITY 131-001 B2016-0000112015 !09,01016 EACHOCCURRENCE s 3,000,010 ]CLAIMS-MADE � X .00CUR I .' PREMI.SFS{Ea DAMAGE TO RENTED]occurrence) ._...5 3,000,000 X SJR:$250,000 j MEO EXP(Any o Person)'- S 5,000 I PERSONAL&ADVINJURY S 3,000,ODO GENT AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 6,000,000 r... i R 1 POLICY L, JECT I._..I LOC im PRODUCTSI-GOMPIOPAGG.f.S..,.. 1 OTHER: I (g A AUTOMOBILE LIABILITY iBAP0182017-00 09/0112015 !09M112016COMBINEO SINGLE LIMIT S 5 L"'-"OD .jEB.eecldentl. .. .. ...... ... X I BODILY INJURY(Per person) S ., .. ANY AUTO I ALL OWNED .. SCHEDULED ........— ..--. ..... X ; X BODILY INJURY (Per accident) S AUTOS ...... AUTOS - XX NON-OWNED PfiOPE RTY DAMAGE S HIR .._. AUTOS iRpr accdgenl............._ _ COMPICOLL DED: S $5,000 UMBRELLA LIAR I OCCUR � EACH OCCURRENCE S . EXCESS LIATB CLAIMS-MADE,jI AGGREGATE._...... ....._}S_ ... ...... ..-...... ... .. DED..I .....I RETENTIONS D WORKERS COMPENSATION WC0182014-DO(AOS) 0810172015 09101/2016 X I PER TH ± i.STATOTE_ .. Eft AND EMPLOYERS'LIABILITY _. }... ._..... .. ....: A ANV PROPRIETORlPARTNERIEXECUTIVE YNf❑N NIA CD182015•00(MA) O9;D112015 09l01I2D46 E L EACH ACCIDENT $ 1 ODD D00 OFFICERlMEMBER EXCLUOEDT IWC DEDUCTIBLE $00,000 tE.L.DISEASE-EA EMPLOYE S tManda4ary In NH) 1,000,000 Ir es-describe undef .. .. .. .-.- ...... y _. —1D ESCRIPTION OF OPERATIONS baloN ! E L DISEASE-POLICY LIMIT $ 1,000,000 k f DESCRIPTION OF OPERATIONS 1 LOCATIONS f VEHICLES tACORO 1In.Additional Remarks Schedule,may be attached K more space Is requ)redl Evidence of insurance. CERTIFICATE HOLDER CANCELLATION SDIaraly Corporation SHOULD ANY OF THE ABOVE OF-SCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 89402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHOWWO REPRESENTATIVE of Marsh Risk&Insurance Services Charles Marmolejo 0 1988-2814 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:288156FE-DO6B-46F4-AE3A-95F5B7B21AAB SolarCity I PPA Customer Name and Address Installation Location Date Donna Schmith 26 Tara Cir 4/18/2016 26 Tara Cir Lot 15 L15 Pole 2-6 Northampton,MA 01060 Northampton,MA 011060 re are the key terms of your Power Purdijase Agreement�,`' ILE 7 VAN" Lussrs Sy+stern Installation cost' Electricity rfo r kWh Agreement Tglm DS Initial her , .,,, Initial hertTe _ IDS The SolarCity Promise DS •We guarantee that if you sell your Home,the buyer will qualify to,assume your Agreement. __...... ..................._. initial here •We warrant all of our roofing work. os •We restore your roof at the end of the Agreement. DS •We warrant, insure, maintain and repair the System. __._ initial here •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 4/18/2016. Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: +At certain times,as specified in 0 •SolarCity will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 •You can upgrade to a new System with •These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est.amount due at building inspection contract. not beyond that term. $0 •You may purchase the System from Est.first year production SolarCity for its fair market value as 2,266 kWh specified in the Agreement. You may renew this Agreement for up to ten(10)years in two(2)five(5)year increments. 3055 Clearviw Way,San Mateo,CA 94402 ] 8$8.7652489 sOlarcity.Com 1761393 Power Purchase Agreement,version 9.2.0,March 28,2016 SAPC/SEFA Compliant Contractors License MA HIC 168572/EL-1136MR Document generated on 4/18/2016 Copyright 2008-2015 SolarCity Corporation,All Rights Reserved i__ DocuSign Envelope ID:288156FE-DO6B-46F4-AE3A-95F5B7B21AAB 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Donna Schmith EXPLANATION OF THIS RIGHT. 24. ADDITIONAL RIGHTS TO CANCEL, DocuSigned by: IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL Signature: I�"""'' ' �"""'`., THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL THIS PPA AT NO COST AT ANY TIME PRIOR TO Dater 4/18/2016 COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. 'Pricing The pricing in this PPA is valid for 30 days after 4/18/2016. If you don't sign this PPA and return it to us on or prior to Customer's Name: 30 days after 4/18/2016,SolarCity reserves the right to reject this PPA unless you agree to our then current pricing. Signature: Date: Power Purchase Agreement SolarCity approved Signature: - Lyndon Rive, CEO Date: 4/18/2016 n.,,tlj v,, t ��jMa,,, ❑� � 751393 Version#56.4-TBD SolarCity. April 23, 2016 A3 LARDO E. RE: CERTIFICATION LETTER V DE VERA H 4 v STRUCTURAL Project/Job# 0102115 '. No. 52160 Project Address: Schmith Residence 26 Tara Cir A X,9FG1STfiA���t'•�4. ' SSEN6 Northampton, MA 01060 FfONA� Digitally signed by Abe De Vera AHJ Northampton Abe De Vera s°IarCl,yDsers,°°="ab°r^e. SC Office Springfield ^-Abe°ege,a. mail=adever 16 23rc27c Dale:3016.04 3316.31'.11-0)'00' Design Criteria: -Applicable Codes = MA Res.Code, 8th Edition,ASCE 7-05, and 7005 NDS - Risk Category = II -Wind Speed =90 mph, Exposure Category C -Ground Snow Load = 40 psf - MP1: Roof DL = 10.5 psf, Roof LL/SL= 28 psf(Non-PV Areas),Roof LL/SL= 28 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 011.22462 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. Sincerely, Abe De Vera,P.E. Professional Engineer Main: 888,765.2489, x57526 emaill: adevera@solarcity.com ntlo t.i. ,t10; Version#56.4-TBD SolarCity, HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI 64" 24" 39" NA Staggered 39.6% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi 48" 17" 65" NA Staggered 49.4% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MPI Stick Frame @ 16 in.O.C. 200 Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1 Member Prope ies Summary MPI Hod ontal Member Spans Rafter Pro rties Ove ang 0.66 ft Actual W 1.50" Roof System Pro erties spa 1 12.30 ft Actual D 7,25" Number of Spans w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Spa 3 A 10.88 in.^2 Re-Roof No Spa 4 SX 13.14 in A3 PI ood Sheathing Yes S a 5 1 47.63 in.^4 Board Sheathing None Total Ra e S an 13.79 ft TL DefPn Limit 120 Vaulted Ceiling No PV 1 tart' 3.08 ft` Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1Ort d 12.92 ft Wood Grade #2 Rafter Slope 20°'' PV 2 I Fb 875 psi Rafter S acin 16"O.C. PV 21End F„ 135 psi Top Lat Oracing Full PV 3 rt E 1400000 psi Bot Lat Bracing At Supports PV 3End Emi„ 510000 psi Member Load ng Summary Roof Pitch 5/12 Ini al Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.5psf x 1.06 11.2 psf 11.2 psf PV Dead load PV-DL 3.0 x 1.06 3.2 psf Roof Live Load RLL 20.0 11 x 0.98 19.5 psf Give/Snow Load LL SL"' 40.0 psf x 0.7 ( x 0.7 28.0 psf 28.0 psf Total Load(Goveming LC I TL 1 39.2 psf 42.4 psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0. (Ce)(Q)(IS)Pg; Ce=0.9,Q=1-117=1.0 Member sign S mmary(per NDS Governing Load Comb I CD CL CL - CF Cr D+S 1.15 1. 0 0.47 1 1.2 1.15 Member Analysis esults Summary Governing Analysis Max Demand 1 0 Lo tion Capacity DCR Result Bending + Stress 964 psi 6.81ft 1389 psi 0.69 Pass CALCULATION OF DESIGN WIND LOADS - MP1 Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 200 Rafter Spacing 16"O.C. Framing Type/Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA ,Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category; C Section6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof'Hei ht h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor KA 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance'Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 psf Wind Pressure Ext. Pressure Coefficient U GCp(Up) -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down G Down 0.45 Fig.6-116/C/D-14A/8 Design Wind Pressure p p = qh(GCp) Equation 6-22 Wind Pressure U -13.1 psf Wind Pressure Down P(down)1 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -198 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 39.6% X-Direction Y-Direction Max Allowable Standoff Spacinq Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -247 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 49.4% T ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING CITY OF NORTHAMPTON EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BUILDING DEPARTMENT FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY {, }, HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. These plans have been reviewed I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL And r Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(6). approved. Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR {/ kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC Date / l LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. Signatur NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL -UPS UNINTERRUPTIBLE POWER SUPPLY -- V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEETPV2 PROPERTY PLAN PV3 SITE PLAN PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 UPLIFT CALCULATIONS PV6 THREE LINE DIAGRAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED L— THE INFORMATION HEREIN JOBNUAreER JB-0102115 00 DONNA SCHMITH Donna Schmith RESIDENCE AJ Peters !a } CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �„_ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 26 TAR CIR -2.08 KW PV ARRAY ►1� olar `y PART TO OTHERS OUTSIDE THE RECIPIENTS P n' NORTHAMPTON MA 01060 ORGANIZATION, EXCEPT IN CONNECTION WITH > THE SALE AND USE OF THE RESPECTIVE (8) TRINA SOLAR # TSM-260PDO5.18 24 St Martin Drive.Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTENMVERTER PAGE NAME: SHEET: REV: DATE Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. T. (650)638-1026 F: (650)638-1029 SOLAREDGE SE3000A—USOOOSNR2 COVER SHEET PV 1 4/23/2016 (888)—sOL-CITY(765-2489) www.solarcitycom PROPERTY PLAN N Scale:l" = 20'-0' w E 0 20' 40.' S PREMISE OTAVER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN 106 NUMBER JB-01 02115 00 AJ Peters SolarCity CONTAINED SHALL NOT BE USED FOR THE DONNA SCHMITH Donna Schmith RESIDENCE 0,,, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �I� NOR SHALL IT BE DISCLOSED IN VMOLE OR IN Comp Mount Type C 26 TARA CIR 2.08 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NORTHAMPTONMA 01060 ORGANIZATION,EXCEPT IN CONNECTION VATH MODULES: , 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (8) TRINA SOLAR # TSM-260PDO5.18 SHEEP. REV: DATE: Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T. (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE3000A—USOOOSNR2 PROPERTY PLAN PV 2 4/23/2016 (888)-soL—CITY(765-2489) wwww.solarcity.com PITCH: 20 ARRAY PITCH:20 MP1 AZIMUTH: 178 ARRAY AZIMUTH: 178 MATERIAL:Comp Shingle STORY: 1 Story LEGEND (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS MP1 gg DC DISCONNECT & WARNING LABELS -- T_---- AG AC DISCONNECT & WARNING-LABELS AC -JM AC Inv 0 DC JUNCTION/COMBINER BOX & LABELS 000 Al A oD DISTRIBUTION PANEL & LABELS 2 �s�eyG LG LOAD CENTER & WARNING LABELS Front Of House AS LARDE3 DE VA 'v STRUCTU At u' M DEDICATED PV SYSTEM METER No, 52160 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR �St NAL�a� CONDUIT RUN ON INTERIOR Digitally signed by Abe De Vera GATE/FENCE Abe De DN:d-local,dcdolarCity, o HEAT PRODUCING VENTS ARE RED SolarCity D=et=, —Haws—,,cn=Abe De Vera, r 1 Vera DateII2016.04.23f631199-0�00 J INTERIOR EQUIPMENT IS DASHED STAMPED AND SIGNED SITE PLAN N FOR STRUCTURAL URL ('SNI V Scale: 1/8" = 1' W E �✓ t I�. ONLY L 1 0 1' 8' 16' S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-0102115 00 PREMISE OYMER: DESCRIPTION: DESIGN: DONNA SCHMITH Donna Schmith RESIDENCE AJ Peters SolarCity.CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount T e C 26 TARA CIR 2.08 KW PV ARRAY ►� PART TO OTHERS OUTSIDE THE RECIPIENTS p ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES NORTHAMPTON, M A 01060 THE SALE AND USE OF THE RESPECTIVE (8) TRINA SOLAR # TSM-260PDO5.18 24 St Martin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV. DATE: Mariborough,MA 01752 PERMISSION OF SOLARCITY INC. T: (650)638-1026 F: (650)638-1029 SOLAREDGE SE3000A-USOOOSNR2 SITE PLAN PV 3 4/23/2016 (888)-SOL-CITY(765-2489) www.sdarcitycom S1 12'-4" 01 (E) LBW A SIDE VIEW OF MP1 NTS MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED PORTRAIT 4811 17t1 RAFTER 2X8 @ 16" OC ROOFAZI 178 PITCH 20 RRAY AZI 178 PITCH 20 STORIES: 1 C.J. 2x6 @16" OC Comp Shingle �C, PV MODULE t"� AR LARIJO E. .f' 6 VE r A a 5/16" BOLT WITH INSTALLATION ORDER STRUCTURAL FENDER WASHERS No.52160LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ,9a� ' isT ZEP ARRAY SKIRT (6) HOLE. 5 1�3NAi i i itally signed by Abe De Vera SEAL PILOT HOLE WITH Abe DN:d-local,dc-SolarCity, (4) (2) POLYURETHANE SEALANT. ou-SnlarCity Users, om ZEP COMP MOUNT C _ r Flawth.denrne,colAbe.c Vera, _ _ _ Vera^, email=016.04.era2s 6:32:35-07' (� Date:2016.04.2316:32:35-0700' ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER 1 STANDOFF PREMISE OWNER: DESCRIPTION: DESIGN:- CONFIDENTIAL ESIGN: 1 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 02115 00 AJ Peters .�\r,;COIarC'T\ CONTAINED SHALL NOT BE USED FOR THE DONNA SCHMITH Donna Schmith RESIDENCE '''��_ `Y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 26 TARA CIR 2.08 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON, MA 01060 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St Martin Drive,Budding 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (8) TRINA SOLAR # TSM-260PDO5.18 SHEET: REV: DATE: Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T: (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE3000A—US000SNR2 STRUCTURAL VIEWS PV 4 4/23/2016 (8W)-SOL—CITY(765-2489) www.solarcity.com UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBERPREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR 1HE JB-01 0 2115 0 0 DONNA SCH M I TH BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Donna Schmith RESIDENCE AJ Peters NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 26 TARA CIR 2.08 KW PV ARRAY 1►i;SolarCity. PART TO OTHERS OUTSIDE THE RECIPIENTS M ODULES: NORTHAMPTON MA 01060 ORGANIZATION, EXCEPT IN CONNECTION YWTH ' 24 St Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE SOLAR # TSM-260PD05.18 9 SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN PAGE NAME SHEET: REV DATE: T: (650)638-1028h. . 01752 (650)638-1029 PERMISSION OF SOLARCITY INC. E SE3000A—USOOOSNR2 UPLIFT CALCULATIONS PV 5 4/23/2016 (866)-SCI-CITY(765-2489) www.solarcitycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:LC120OF Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE J�SE3000A-USOOOSNR2 LABEL: A -(8)TRINA SOLAR TSM-260PDO5.18 GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:74 934 466 Tie-In: Supply Side Connection Inverter; 30 OW, 24OV, 97.5%; w/Unifed Disco and ZB,RGM,AFCI PV Module; OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Ise AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 100A MAIN SERVICE PANEL E 100A/21? MAIN CIRCUIT BREAKER Inverter I E WIRING CUTLER-HAMMER O CUTLER-HAMMER Disconnect 100A/2P 3 Disconnect 2 SOLAREDGE A 20A B SE3000A-USOOOSNR2 A L1 2aov B L2 N L DC+ (E) LOADS GND _ ____ GND --___-____--__-__-------- EGC/ T DC+ DC- GEC ——— N Dc- MP1: 1x8 �~ GND __ EGC-—-—-----------—-----------—----------- EGC----------------- *� � r---J y 1 N 1 I _J o � _ES z I I I 1 I - GECT-1 TO 120/240V SINGLE PHASE I I UTILITY SERVICE I 1 I I I I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP OTT (2)Gr qd Ro# (1)CUTLER—HAMMER #DG222NR8 V (8)SOLAREDGE 300-2NA4AZS DC l 5�8 x 8, C er Disconnect; 60A, 24OVac, Fusible, NEMA 3R AC v PowerBox Optimizer, 3DOW, H4, DC to DC, ZEP —(2)ILSCO/IPC 4�—/6 1 CUTLER—HAMMER DG221UR8 (1)AWG/6, Solid Bare Copper Insulation Piercing Connector, Main 4/0-4, Tap 6-14 B ( ) nd S Disconnect; 30A,y�24OVac, Non—Fusible, NEMA 3R —(1)Ground Rod; 5/8" x 8, Copper SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE —(1)Ground�NdMtrd KitD30ANGeneral Duty(DG) AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION N0. 2, ADDITIONAL ;ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE i # _., 60O._ * AWG 10 P {1)AWG #6, THWN-2, Black {1)AWG#10, THWN-2, Black (2) V Wire, 600V, Black Voc —500 VDC Isc =15 ADC 2 O (1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=5.87 ADC O (1)AWG�, THWN-2, Red O (1)AWG#10, THWN-2, Red (1)AWG#6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=12.5 AAC "' (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=12.5 AAC i .. . . . . . (1)Conduit Kit; 3/4'_E4T. .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . .. . #6,.Solid Bare Copper, GEC. -(1)Conduit,Kit;.3/4'.EMT. . . . . . -,{1)AWG#8TFLWN-2,.Green . . EGC/CEP.-(1)Conduit,Kit;.3/4'.EMT, . . . i PREMISE OWNER DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 02115 00 AJ Peters �\lr CONTAINED SHALL NOT BE USED FOR THE DONNA SCHMITH Donna Schmith RESIDENCE ��,SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 26 TARA CIR 2.08 KW PV ARRAY ��I� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES NORTHAMPTON, MA 01060 24 St Martin Driw,Binding 2 Unit 11 ORGANIZATION, EXCEPT IN CONNECTION WITH Marlborough,MA Building Z THE SALE AND USE OF THE RESPECTIVE LIN'VERTER. 8) TRINA SOLAR # TSM-260PDO5.18 SHEET: REV: DATE T: (650)638oroug F: (617 638-1029 SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: PERMISSION OF SOLARCITY INC. THREE LINE DIAGRAM PV 6 4/23/2016 (888)—SOL—CITY(765-2489) www.solarcitycom OLAREDGE SE3000A—USOOOSNR2 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 26 Tara Cir AC DISCONNECT I AC i r DISCONNECT UTILITY SERVICE INVERTER AND DC DISCONNECT SOLAR PHOTOVOLTAIC ARRAYS) L PH0MI`V%7AIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0102115-00 CONADENTIAL— THE INFORMATION HEREIN JOB NUMM: JB-01 0 2115 00 PREMISE OWNER DESCRIPTION. DESIGN: CONTAINED SHALL NOT BEE USED FOR THE DONNA SCHMITH Donna Schmith RESIDENCE AJ Peters SolarCity. BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 26 TARA CIR 2.08 KW PV ARRAY ��� PART TO OTHERS OUTSIDE THE RECIPIENT'S '•" ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES NORTHAMPTON, M A 01060 THE SALE AND USE OF THE RESPECTIVE (8) TRINA SOLAR # TSM-260PD05.18 24 SL Martin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTEFc PAGE NAME: SHEET: REV: DATE T: (650)Marlborough, ( 8 ug, 752 638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE # SE3000A—USOOOSNR2 SITE PLAN PLACARD PV 8 4/23/2016 CITY(765-2489) www.sdarcity.c«n el WARNING;PHOTOVOLTAIC POWER SOURCE Label Location: a b • a • a• _ Location: = WARN11G WARNING ••_ ELECTRIC SHOCK HAZARD ••_ NEC •' ELEOTRtGvNOCK HAZAtQ •• 690.35(F) THE DC C©NQUCTORS OF THIS 130 N07 T�}UCH TERMINAL Label • • TERMINALS Cll+t BOTH LINE AND PHOTOVOLTAIC SYSTEIv1 ARE : USED WHEN LEAD SIDES MAY BE ENERGIZEQ UNGROUNDED ANDINVERTERIS PHOTOVOLTAIC DC IN THE OPEN P{3SITION MAY BE ENERGkZED UNGROUNDED DISCONNECT w NEC .•0 LabelLab_ • • PHOTOVOLTAIC POINT OF `• INTERCONNECTION Code: MAXIMUM POWER �A WARNING:ELECTRIC SHOCK POINT CURRENT(Imp) Per ••- HAZARR DO NOT TOUCH NEC 690.17.4; 690.54 MAXIMUM POWER- 690.53 TERMINALS.TERMINALS ON POINT VOLTAGE(Vmp)- BOTH THE LINE AND LOAD SIDE MAXIMUM SYSTEM � MAY BE ENERGIZED IN THE OPEN VOLTAGE(Vocj- POSITION.FOR SERVICE SHORT-CIRCUIT�A DE-ENERGIZE BOTH SOURCE CURRENT{Isc) AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT MAXIMUM AC V Label Location: OPERATING VOLTAGE WARNING Per ••- NEC ELECTRiC SHOCK HAZARD •• IF A GROUND FAULT IS!NDlCATED NORMALCY GROUNDEDLabel L• • CONDUCTORS MAY BE CAUTION `• UNGROUNDED AND ENERGIZED DUAL POWER SOURCEPer Code: SECON'DSOURCEIS NEC690.64.B.4 .PHOTOVOLTAIC SYSTEM Label • • Per Code: Label WARNING Location: ELECTRICAL SHOCK HAZARD CAUTION ' • DO NOT TOUCH TERMINALS � TERMINALS ON BOTH LINE ANDPer Code: LORD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM 690.64.13.4 IN THE OPEN POSITION CIRCUIT IS BACKFED DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNLNG :-OCode: INVERTER OUTPUT •- • • CONNECTION NEC 690.64.13.7 Disconnect PHOTOVOLTAIC AC �� DO NOT RELOCATE THIS OVERCURRENTConduit NEC DISCONNECT �; DEVICE • - :. Distribution Interior(DC): DC Disconnect . . IntegratedLabel Location: (INV): Inverter With DC Disconnect MAXIMUM AC •'• OPERATING CURRENT - A Per AC VNEC •« '• Point of • • OPERATING VOLTAGE 305S Cleai • 11• • • 1 / 71 •• . :7 1 • r 1 • 1 r •� 1 •1 Mateo,San 0 1638-1029 LabelSet (888)-SOL-CITY(765-2489)www.solarcity.com ow ® _, 13 ''�'t,SOlarCitY I ZepSolar Next-Level PV Mounting Technology -i-SOlarCity ZepSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs �` .. - -- .......... __.-__ C's Leveling Foot Ground Zep ZnhutasAt €_� -- Part No.850-1172 - ¢� ETL listed to UL 467 zep compoual gv roa,ac r 1 _ �.. ROO nttachmc t , Array Skirt ,... Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 ¢,eMPAT/, er,� Description � • PV mounting solution for composition shingle roofs ' .. FA /e` Works with all Zep Compatible Modules c°Nvpt�v Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" �L LISTEDInterlock Ground Zep V2 DC Wire Clip Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Designed for pitched roofs Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, zepsolar.com zepsolar.com Listed o L 156567 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM II solar " ® � So l a r'=g@ SolarEdge Power Optimizer Module Add-On for North America P300 ; P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America (formodules) tf®rodulesPv (to,modules) '�, modules) modules) .modules) , INPUT P300 , P350 / P400 ® 1 Sated Input DC Powe iii 300 350-. 400 __-- W- Absolute Maximum Input Voltage(Voc at Icwest temperatcre) 49 60 80 Vdc �;>£ � 8-48 8-60 8-80 Vol, �r "g-01 t h �, Mogi Opeadng Range p g y f Maximum Short Circuit Current(Isc) 10 Adc �1 Maximum DC Input current 12.5 Adc Maximum Efficiency 99.5 i , 99.8 Weighted l ' _ r $ Overvolt ge Category OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Adc Maximum Outnut OutputCurrent Ju Maximum Output Voltage 50 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimize, -._ 1 _ Vdc NO s�6" ... ` STANDARD COMPLIANCE _ '' G' 'MC . pa CC •t'5 Class':IEC61000 6 2 1 062000E`s _ 'y � 2 Sa*et IEC62109 ( ass II safety),U..1741 y S Yes_ _.. INSTALLATION SPECIFICATIONS _. Maximum Allowed System Voltage 1000 Vdc Dirrens:ons(W x I x H) 141 x.212x 40.5/S.5S x 8.34 x 1.59 mrn/in Weight(including cables) 950/21 gr .b Input Connector MC4/Amphe nil/Tyco Output Wire Type/Connector Double InsWated;Ampnenel Output Wire Length 0.55/30 1.2/3.9 m/`:t Operating Temperature Range -40-+85/-40- C/ F dT Protection Rating IP65/NEMA4 Reiatwe iwmidi:y 0-ono PV SYSTEM DESIGN USING A SOLAREDGE - SINGLE PHASE__-- THREE PHASE THREE PHASE - INVERTER _.... _...... ___ ._.. 208V. _..... 4$0V PV power optimization at the:rnodfUle'46vel Minim t ng ength(Power OPtimizersl 8 10 lfl Maximum String Length(?ower Oohmi-1) 25 25 SG - Up to 25%more energy ! Maximum Power per String 5250 6000 12750 ', W Superior efficiency(99.5%) Parallel Strings of Different Lengths or Orientations Yes — Mitigates all types of module mismatch josses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization - Fast installation with a single bolt - Neat generation maintenance with module,leve)monitoring — Module-level voltage shutdown for installer and firefighter safety: - THE Vinamount MODULE -P . Mono Multi Solutions ............. ..... DIMENSIONS OF PV MODULE ETECTRICAL DATA i-STC Unit:nlm Peak Power Watts-P.-(Wp) 245 250 255 260 941 ## rv.MecrerE Power Output Tolerance-P-f%) 0-+3 o Maximum Power Voltage-I (V) 29.9 30.3 30.5 30.6 TME Tirinal 1 1 rvarory I o I Maximum Power Currant I e (n) 8.20 8.27 8:37 8.50 o Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 382 60ruurvc rvoie Short Circuit Cunrent-Isc IA) 8.75 8.79 . 8.88 '.9.00 s Module Efficiency qm(%) 15.0 15.3 15.6 15.9 STC:Irradiance 1000 W/m2,Cell Temperature 25°C,Air Mass ANU 5 acordi.g to EN 60904-3MODULE - Typical efficiency reduction of 4.5%at 200 W/m'accord ng to EN 60904-1. O O E!EC'RICAL DATA .cOC' �� Maximum Power-P-(Wp) 162 186 190 193 60 CEMaximum Power Voltage-Vere(V) 27.6 28.0 28A 28.3 MULTICRYSTALLINE MODULE a 4scxourvwrvc HOLE Maximum Power Current Imre(A) 6.59 6.65 6.74 6.84 WFTH Ttt�NAME7UNT FRAME owrvrvorE a A, Open Circuit Voltage(V)Vac(V) 35,1 35.2 35.3 35,4 Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 7.27 - i NOCT:Irradiance at 800 w/m',Ambient Temperature 20°C,Wind Speed 1 m/s. I PD05.18 atz too Back View POWER OUTPUT RANGE MECHANICAL DATA 11 Solar cells Multicrystolline 156 x 156 mm(6 inches) Fest and simple to install through drop in mounting solution Gell orientation 60 cells(6 x to) 0 Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) 15. --._. _ _ ____ ______ __. rl� i Weight _ 21.3 kg(47.0 lbs) Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass A-A Backsheet White Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove IP 65 or IP 67 rated IAB/�'3% [-V CURVES OF PV C?r1UtE('?4SSd Cables '.. "T Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), .............. .._......... ......... ......... ._...__... to.- 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 9°.--J000Wlm= &.- Fire Rating Type -- 800W/m= Highly reliable due to stringent quality control Q 6 O nWJOwIm'AS _ d 5 J .l��`srior'Jfrc..11E,-` _. - .f Ut a4°,-496y1m" TE.iPERkTIRE RATINGS MAXIMUM RATINGS 200W/m Nominal Operating Cell Operational Temperature -40-+85°C t C IF}. a is (� T _.... _ ,,,,,_ 44°C(±2^C) Temperature(NOCT) ex -.r i_nil,e� ,-z i?@rS - _. '� ;: Maximum System 1000VDC(IEC)- ri - ..___...._.._. .......... ..... ............................. __........ pm>.__. ._._ ___-_-- - Temperature Coefficient of P-x 0.41%/°C ' Voltage 1000VDCJLIQ E_ ;t{I:,J, :�{,ry. 0.. To.- 2aw 3010 40,- L 0�w g F :'i C'`ciround N r.. 5 i.intj Temperature Coefficient of Voc -0.32%/'C Max Series Fuse Rating 15A Voltage(V) Certified to withstand challenging environmental Temperature Coefficient of 1. 0.057./°C c novf �w, conditions 7 t.- b.w k.,'JI- WARRANTY x tnel_ t cr rri r II'cu 10 year Product Workmanship Warranty T� J, r t.. ( rf ::I Y 25 year linear Power Warranty aval.,:_c.-, 1i -.m-._r_ (Please refer to product warranty for details) < C,-- s the - i „ r-� a, G ,3I"...re r.,s :,55!h CERTIFICATION LINEAR PERFORMANCE WARRANTYPACKAGING CONFIGURATION m - - - -- -- --- `OU= o.- Q 10 Year Product Warranty 25 Year Linear Power Warranty u� Modules per box:26 pieces Tribe Scxiarliited ; 71dd}ff........... -efr .__ Modules per 40'contoiner,728pieces r 1/ I fir; !u n7 TrttTa s „too +Cel a° atlp{Va Euu�ee a a 0 90°,G �a/af 1pnaf Warranty CAUTION'.READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. aUlApaTe 8 ©2014Trina Solar L r ed.All rights reserved.Specifications included in this datasheet are subject to yF, e7 80% change w thou}not'ceTrin . Smart Er .�lelll ...i •< w, Years 5 10 15 20 25 ept4pp'(e (l;- a,-1 a 11 THE Teinamount MODULE TSM-PDO5.18 Mono Multi Solutions DIMENSIONS OF PVMODULE ELECTRICAL DATA a STC up,it:mrn Peak Power Watts-Pmnx(Wp) 250 255 260 265 941 _ Power Output Tolerance-P-(%J. 0^+3 Maximum Power Voltage-Vmr(V) 30.3 30.5 30.6 30.8 FTX THE �II eAre Maximum Power Current-Impr(A)" 8.22 8.37 8.50 8.61 Trina I U t 4 o Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 38.3 wsrauieO HOLE ° Short Circuit Current-lsc(A) 8.79 '8.88 9.00 9.10 i Module Efficiency qm(%) 15.3 15.6 15.9 16.2 MODULE STC:Irradiance 1000 W/m',Cell Temperature 25"C,Air Mass AM1.5 according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. 0 =o ELECTRICAL DATA:X PIOC.'T Maximum Power-Pmnx(Wp) 186 190 193 197 60 CELL Maximum Power Voltage-V-(V) 28.0 ;,28.1 28.3 28,4 Maximum Power Current-]-(A) 6.65 6.74 6.84 6.93 MULTICRYSTALLINE MODULE ,.... , . ,...,. � Open Circuit Voltage(V)Vac(V) 35.2 35.3 35.4 35,5 PD05.18 WITH TRINAi1 NT faAME ,,.o�,iHHerf Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 _ NOCT:Irrodiance at 800 W/m2,Ambient Temperature 20°C,Wind Speed I m/s. 812 780 250.- 6 W Back ViewC t?E;NAtdI�AL DATA fiT'A POWER OUTPUT RANGESolar cells Multicrystalline 156 x 156 mm(6 inches) �� I Fest and simple t€ install throu h crop in rr ountin solution T Cell orientation 60 cells(6 x 10) Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 Inches) Colt 16.27o , -. ..__ _._ _... o weight 3.2ff o (43 12 nc v _..._..._ _._ ._..____. ___._ -_._ ___ I,�I, Glass 3.2 from(0 13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY Backsheet White ---__-_. A-A Frame Black Anodized Aluminium Alloy Good aesthetics for residential applications 3-Bax IP 65 or IP 67 rated s= Cables Photoyoltaic Technology cable 4.0 mm'(0.006 inches'), �f __-- _-- _ 1200 mm(47.2 inches) I-V CURVES OF F`V i,+,OU`U�,E i�,vW'j Connector H4 AmpBenot POSITIVE POWER TOLERANCE M. soo r000w/m, _ Fire Type UL 1703 Type 2 for Solar City Highly hly relia le due to stringent c u llty control avow/ i s. - I_MPERA JR..RATINGS MAXIMUM RATINGS E 5-00 Nominal Operator Cell Operational Temperature 40-+85°C ., .,,= T coo 419T/p{-. ._ _-. Temperature(NOCT) 44°C(-+2°C) .<t}-, ''tc'. Maximum System 1000VOC(IEC) .. . .......... .............. , tent of IF- -0.41%/°C Voltage 1000V DC(UL) zowTemperature Temperature Coefficient of Voc -0.32%/OC Max Series Fuse Rating 15A so ,o ao ao ao Temperature Coefficient of tsc 0-05%/°C. r v Certified to withstandchallenging environmental ,. - varse{vt conditions I - 1 WARRANT' I CERTIFICATION 10 year Product Workmanship Warranty 25 year Linear Power Warranty ®RL (Please refer to product warranty for details) ULISTED r vi i� ,1 ng;n: LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION EU 18 W FEf � _... -Yea-r-15 _ _- CCCOMPl1ANl .._....... ... .. ......... .:.._... ........._.... 1�Ye"'aC P7OG§ t3tFa n$y 1'2f5C 1<I51�i`1(P4sE?i CBLS Iity Modules per box'26 pieces _. N Tuna Solar Urnited '` .-` ---- - -.' .-- Modules,per 40'container:728 pieces ya ➢ } fCr'cJEF linear war, w - -, ONINSTALLATION' INSTRUCTIONS lgEOUSING HPRODUCT. �G OPAT ,fro 90% ant2015 Trina Solar LimitedTrinasolar ,All reservedSPeci(cat Onincluded n ihidatasheet are sublet to change withot note 80% t j nCa aMPPO Smart'Ene a,T'trf"" Years 5 10 IS 20 25 e i Single Phase Inverters for North America SE3000A-US,SE380OA-US/SE5000AUS SE6000A-US SE7600A-US 1 SE1000OA-US/SE1140CA-US SE3000A US SE380OA US! SESOOOA-US SE6000A-USI SE7600A-USS SE10000A-US SE1140OA-US OUTPUT Nominal Ar Power Output 3000 3800 SDOD f,00G 7600 9986 @ 208V 11400 VA SolarEdge Single Phase Inverters . :0000@240V 5400 @ 208V 10800 @ 208V For North America Max.AC Power Output .3300 4150 5 450 @240V 600t; 8350 10950 @240V 12000 VA AC Output Voltage Min.-Nom:Max `l ✓ 183-"208-229 Vac SE300OA-US/SE380OA-US,'SE5000A-US!SE600OA-US/ AC Output Voltage Min.-Nom:Max" ✓ f f , f -264 Vac SE760OA-US/ SE1000OA-US SE11400A-US ACFreg0ncyMi AC Frequency Min:Nomi 59.1-60-60.5(wRh HI country setting 57-60-605) ' Hz a r s Max Continues Output Current 12 16 -4 @ 208V 25 32 48{d 208V47.5 A �, b x.:od¥ a 21'a 240V 42 @ 240V GrJI hreshc d - A 4tility Mon toring,Isla d`�g Protecticn,Country ConSgurab e"hresholds .._._ ..__Yes INPUTYes ._.. 3 ._. _. .._ ._ ... _ ya ter�� Maximum:'sC Power(S Ci 4050 5100 6750 ..8100 ....10250 =3500. ._15450 W transformer less,l,ngrounoed Yes . - q e� a Max.Input Voltage Soo Vdc �e8 a `� s, Nom.DC nput Voltage 325 @ 208V/350 @ 240V Vdc. M wa �- 16,S @ 208V 33 @ 208V Max Input CurenMl 9.r; 1.3 @_ 18 23 �„ 34.1 Adc " Max Input Short Circuit Current 4J 45 30 L -JV Adc 1 'z 0V , 5 n 2 e L� ° u. Reverse-Four ty P-otec on Yes Crouns-Fault Isclation Detection 600xn Sensitivity _ Maximum Inverter Efficiency 97.7 98.2 983 983 98 98 98 rQ. 97 S 208V 97 @ 2C8V %' C_EC Weighted E'fiaerc:y 97 5 9$ .8{a;4CV 97 S 9;S 97 S @ 240V Y ghttime Power Cor.umpton <2.5 <4 W ,y 3 ,'-i;% ,` `. ADDITIONAL FEATURES Supported Communication Interfaces - -- RS485,RS232,Ethernet 7igl3 top Chorial) f� Revenue Grade d Data;ANSI C'2 S Optonaini � -Rapid Shutdown NEC 20,4 690.1? ,.. I�nctonahty enabled'rohen Solar-age rapid sh.,4dnwn kit s,•tstalfed�ti - — COMPLIANCE.. — ... — __...... UL17 _ SA 22 2 STANDARD 41 UL1699B U 1998 C _ Gid Connection Standards I ELE1547 7 cmiss.ons -CC par'15 lass R u .: ......._. ._....... ......... INSTALLATION SPECIFICATIONS _ _— — -- ` " i AC output conduit size/AWG range 3/4"minimum/16 6 AWG 3/4"minimum/8-3 AWG DC input conduit size/N of strings j 3/4"minimum%1-2 strings 6-6 AWG : 3/4"minimum J 1-2 strings/ _AWG range g 1.4.6 AWG Dimensions with Safety Switch 0.5 x 12.5 x 10.5/ in/ •�,. 30.5 x 12.5 x 7.2/775 x 315 x 184 3 (HxVJx D) 775 x 315 x 260 mm Weight with Safety Switch S1,2/23.2 54.7/24.1 88.4/40.1 Ib/kg . ':. NaturalAlk 1.. convection Cooling Natural Convection and nternal Fans;user replaceable) fan(use, The best CF1tifC�fE1P 5c larEd a enabled sys ms reply eable) Noise <25 <50 dBA Aw lotegrated arc fault protection(Type 1 for NEC 201169oullicom pliance Min-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version available"') °F/-C '.- Superior efficbency(98% Range p � Protection Rang NEMA 3R Small,lightweight and easy to install on provided bracket °For other reg onal segs Please eontaet 6 I Edg ,port. Built-in (,, .s A higher current source may be used;the'nverter w,If I,m t it,input current to the values stated. - Built-in module-level monitoring "Revenue gradennverter P/N:SExxxxA-USOOONNR2(for 7600W In ,,ter_SE7600A-US002NNR2J. Ethernet H °Rap d shutdown Kt P/N SE1000-RSD-sl. ® Internet connection through Ethernet or Wireless s-40 version P/N:SE....A-USOOONNU4(for 7600W inverter:SE7600A-US002NNU4). — outdoor and indoor installation VY Fixed voltage inverter,DC/AC conversion only Pre-assembled Safety Switch for faster installation ® Optional—revenue grade data,ANSI 012.1 T T Stu c RoHS L. A GfRM,iNY-IT I.A.' ..kr`N ..I r"-. .,11;_TPPUL A THE t.F L<-'SE,'t__ aY7 cvts v.old Cc-fd gem,LIS