Loading...
30B-045 (3) 25 HINCKLEY ST BP-2016-1180 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 30B-045 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-1180 Project# JS-2016-002034 Est. Cost: $20000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq.ft.): 8712.00 Owner: STAWARZ SARAH Zoning: URB(100) Applicant. SOLARCITY CORP AT. 25 HINCKLEY ST Applicant Address: Phone: Insurance: 604 SILVER ST (978)215-2369 ) Workers Compensation AGAWAMMA01001 ISSUED ON:4/13/2016 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 7.8 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 4/13/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2016-1180 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (978)215-2369() PROPERTY LOCATION 25 HINCKLEY ST MAP 30B PARCEL 045 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: INSTALL ROOF MOUNTED 7.8 KW SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Buildin,,Plans Included: Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFPRMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Deolition ay Sig re o uil in O ficial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning& Development for more information. Department use only 'ty o Northamptontps of Permit B 'din Department C6ptbV6Hv6Way Permit 2 2 in Street SOW" OftAva l ifl PQM G�oN oo 100 Water/Well Avg#-pity pton, MA 01060 Two Seta ucturai Pl' v��oa -587-1240 Fax 413-587-1272 - a APPLICATION TO CONSTRUCT,ALTER,REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 25 Hinckley St Map LotUnit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Sarah Stawarz 25 Hinckley St,Florence MA 01062 Name(Print) Current Mailing Address: 413-695-6382 Telephone Signature 2.2 Authorized Agent: SolarCity CorpNictoria Junck 604 Silver St Agawam MA 01001 Name(Pri ) Current Mailing Address: 978-215-2367 gn ure Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 6,000 (a)Building Permit Fee 2. Electrical 14,000 (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total=0 +2+3+4+5) 20,000 Check Number This Section For Official Use Only Building Permit Number: DateIssued: Signature: Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding[ ] Other ✓0 Brief Description of Proposed Work: Install solar electric panels to roof of existing home,to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existina housina,'Gomplete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Sarah Stawarz as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 04/07/2016 Signature of Owner Date SOLARCITY CORPNICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORPNICTORIA JUN Print Name 04/07/2016 Sign re f gent Date SECTION 8-CONSTRUCTION SERVICES ' 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Address Expiration Date 978-875-1698 Signature Telephone 9.Realstered dome Improvement Contractor: Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 0100 03/08/2017 Address Expiration Date Telephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11 - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the buildine permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature The Commonwealth of Massachusetts Department of IndustrialAceidents ,( Office of Investigations ►_ . i : �; I Congress Street,Suite 100 7 Boston,MA 02114-2017 wivic nass.gop1dlia Workers'Colllapensafton Insurance Affidavit:BuildersiContractors/Electriciand.plumbers Applicant n orrn tion Please.Print Le ibl Name(Businewotganizationfindividual): SO"ARCIN CORP Address:3055 CLEARVIEW WAY City/State/Zi :SAN MATEO, CA 94402 P11t3tte#:888-765-2489 Are you an employer?Check time appropriate box: 'Type of project(required): 1.9 1 am a employer with 5000 4. ❑ I am a general contractor and 1 6 ©New construction ctnployces(full and/or part-time),* have hired the sub-contractors 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have S. ❑Demolition working for me in any capacity. employees and have%vorkers' 9. ❑Building addition jNo workers'comp_insurance comp.insurance.[ l0. Electrical repairs or additions Te S. ❑ We are a corporation and its - P 3.❑ I am a homeowner doing sit work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGs.. 12_0 Roof repairs insurance required]t c. 152,§1(4),and we have no SOLAR/AV employees.[No workers' !3.®011ier comp.insurance required.] *Any applicant that cirecb box#I must also fill oat the section below sl;wviag illeir workers'compensation policy information. I tlomtowaets who submit this affrdayll indicating they arc doing all work and then hire outside conttat.'lors must submit a new affidavit indicating such, [Contractors that check this box must attached an additional slicer showing the name of the sub-wntractors and state whether or not those entities have employees. Irthesub-contraclonhave amployccs,they mustprovide their Wutlaers'comp.policy number, I trio an emptoyer Flint is providing workers'compensation Imarance far my enyrluy 0. I;telow is the poikv and jab Slte Information. Insurance Company Name: Zurich American Insurance Company Policy If or Self-ins. Lie. #": C01820�4'0Q Expiration Date, 09/01/2016 Job Site Address: J City/State/Zip: fl V� ,V4h 01W2 Attach a copy of the workers'compensation po icy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL e. 152 can lead to lire imposition of criminal penalties of a fine up to$1,500.00 and/or one-year itnprisonntew,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against lire violator. Be advised that a copy of this statement may be forwarded to lite Office of Investigations of the DIA for insurance coverage verification. I ria hereby certify rrndcrtkellains andpenalties ofperJerrir flail the hfrormation provided above is true end correct. ( , 0 4—/ Phone " Official use only. Do riot write in!iris area,to be conspleted by city or town official. City or Town: —Permit/License H Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Towo Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone it: ' ® DATE(MWDDNYYY) A�RV CERTIFICATE OF LIABILITY INSURANCE 0811712015 . . F THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER,THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES- BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(fes)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES NAME:PHONE FAx 345 CALIFORNIA STREET,SUITE 1300 .(ALC R%_EXt)L .- 1.11, .. .....-ijAIC IJoJ•... _.. CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO CA 94104 DRESS_ Alin:Shannon Scott 415m743-8334 tNsuRiS�S)AFFORDING COVERAGE_._.. .,. _. — - 998301-STND-GAWUE-15-16 INSURER A:Zurldi American insurance Company 16535 INSURED INSURER B,.NIA, 'NIA SDIarCityCorporation _}_ 3055 Ctealview Way INSURER c c NIA :NFA San Mateo,CA 94402 INSURER D:American Zurich insurance Company 40142 INSURER E.- INS UK ER .-INSURER F COVERAGES CERTIFICATE NUMBER: SEA-002713836.08 REVISION NUMSSR:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED 13Y PAID CLAIMS. __ INSR ...--'---.._-._......-.. ADf)L SU9R...... . .. __.._.—._._—.....—�T".POLICY t?FF POLICY EXP __ _._..... ........._ -_- -- . ........... T TYPE OF INSURANCE POLICY NUMBER MR)DIYYYY) MMfODIYYYY1 LIMITS A lX :COMMERCIAL GENERAL LIABILITY sGL00182016-00 0910112015 ;09!0112016 EACHOCCURRENCE S 3,000,000 x DAMAGE TO RENTED CLAIMS-MADE OCCUR I ? PR�MISLS tE9 oegurrente)_ _..5 .. _ 3000,000 .. _.__. Ix SIR:$250,000 j � q EXP(Any one person)._ S 5,000 PERSONAL&ADV INJURY 5 3,000,009 GEN'L AGGREGATE LIMIT -APPLIES PERGENERAL AGGREGATE 5 6,000,000 PRO- L l .... .. -_._.. ...... _.. X POLICY L..-J JECT t _ ..€LOC PRODUCTS COMPIOP AGG S 6000000 OTHER: I is A AUTOMOBILE uAsluTr 8AP0182017.00 0910112 0 1 5 •09!01!2016 COMBINEDSINGLE LIMITS 5,00D,000 X. :ANY AUTO j BODILY INJURY(Per person) $ ALL OWNED .. SCHEDULED _U.Y..._.. ...._. ...... _.._.- _...-.. _ X `AUTOS X. AUTOS ®DOILY INJURY(Per acGdent) S ^ I HIREOAUTOS ,x AUTOS I �Pe�ac dd__enl MRGE S jl _ ......... COMP/COLL DED: S $5,000 UMBRELLA LIAR I OCCUR I I EACH OCCURRENCE S EXCESS LIAR #.CLAIMS-AIADEI AGGREGATE __„}6• DED I RETENTIONS I S D WORKERS COMPENSATION WC0182014-DO(AOS) 99MI12015 0901120}g X I PER I 0TH• AND EMPLOYERS'LIABILITY �. �.STAfiU7E-. .._ 1=R... ' ...-.-.. .. ......... A ANY PROPRIETORIPAR7NEWEXECUTIV> Ya NIA A WC0182015.00[MAJ 099112015 09111/2016 E L EACH ACCIDENT t$ 1 000000 OFFICERIMEMBER EXCLUDED? I I ...... .. €._. .-____. #Mandatory In NH) �WC DEDUCTIBLE:$5D0,000 E.L.DISEASE-EA EMPLOYEF4_ 1.ODO,000 If es.describe tinder ... ....._.. .--- ..... I DESCRIPTION OFOPERATIONS below ! EL DISEASE-POLICY LIMIT $ 1,000,000 I I 1 DESCR$PTION OF OPERATIONS I LOCATIONS I VEHICLES tACORD 1 Pi.Additional Remarks Schedule,may be attached K more space Is required# EVIdance o1 Insurance. CERTIFICATE HOLDER CANCELLATION SolarCily Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services I Cttarlm Marrnol0j() '9 1988-2094 ACORD CORPORATION. All rights reserved_ ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:E3E975CA-806C-47D3-A60C-21 C9997F140A SolarCit_ I PPA Customer Name and Address Installation Location Date Sarah Stawarz 25 Hinckley St 11/30/2015 Florence,MA 01062 25 Hinckley St Northampton, MA 01062 Here are the key terms of your Power Purchase Agreement ArM ME U ` 2 0 1 G %W %# zoyf's System installation cost Electricity rat kWh' Agreemen Tim 157'A Initial here mtial here The SolarCity Promise •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. .._.. initial here os_ _�� •We warrant all of our roofing work. os •We restore your roof at the end of the Agreement. •We warrant, insure, maintain and repair the System. ... .... ........... ........................... .. ............... ..............................................._...................... Initial here •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 11/30/2015. Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: .At certain times, as specified in $0 •SolarCity will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 .You can upgrade to a new System with .These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est.amount due at building inspection $0contract. not beyond that term. ' •You may purchase the System from Est.first year production SolarCity for its fair market value as 6,813 kWh specified in the Agreement. •You may renew this Agreement for up to ten (10)years in two(2)five(5)year increments. 3055 Clearview Way, San Mateo, CA 94402 1888.765.2489 1 solarcity.com 1357667 Power Purchase Agreement,version 9.1.0,November 11,2015 SAPC/SEFA Compliant Contractors License MA HIC 168572/EL-1136MR Document generated on 11/30/2015 Copyright 2008-2015 SolarCity Corporation,All Rights Reserved - 5 DocuSign Envelope ID:E3E975CA-806C-47D3-A60C-21C9997F140A 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Sarah Stawarz EXPLANATION OF THIS RIGHT. DocuSigned by: 24. ADDITIONAL RIGHTS TO CANCEL. Signature: IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: 11/30/2015 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after Customer's Name: 11/30/2015. If you don't sign this PPA and return it to us on or prior to 30 days after 11/30/2015,SolarCity reserves Signature: the right to reject this PPA unless you agree to our then current pricing. Date: Power Purchase Agreement SolarCity approved Signature: Lyndon Rive, CEO Date: 11/30/2015 P_.,rE r P')rcl,"se R.e _ ..nrt ver _:,cj n, +c;V1, her ❑� 135'61. ti Version#55.3-TBD SolarCit . RU N OF April 6, 2016 o G CHRIS H. KIM RE: CERTIFICATION LETTER CIVIL Project/Job# 0101734 .09 .52430 Project Address: Stawarz Residence F6� TES 25 Hinckley St Florence, MA 01062 AHJ Northampton SC Office Springfield Digitally signed by CHRIS KIM Design Criteria: Date: 2016.04.06 13:43:55 -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05, and 2005 NDS -04'00' - Risk Category = II -Wind Speed = 90 mph, Exposure Category C -Ground Snow Load = 40 psf - MPI &MP2: Roof DL = 12.5 psf, Roof LL/SL = 28 psf(Non-PV Areas), Roof LL/SL = 18 psf(PV Areas) - MP3: Roof DL = 11 psf, Roof LL/SL = 28 psf(Non-PV Areas), Roof LL/SL = 28 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22424 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure, with upgrades specified in the plans, directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading. The PV assembly hardware specifications are contained in the plans/docs submitted for approval. ,T; w t'7R Version#55.3-TBD SolarCit a UAV HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI&MP2 56" 24" 39" NA Staggered 43.5% MP3 64" 24" 39" NA Staggered 39.4% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1&MP2 56" 20" 65" NA Staggered 72.3% MP3 48" 17" 65" NA Staggered 49.2% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MP1&MP2 Stick Frame @ 28 in.O.C. 320 Member Analysis OK w/Upgrades as Specified in Plans MP3 Stick Frame @ 16 in.O.C. 150 Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. µ SYRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MPI & MP2 Member Prop rties Summary MPl &MP2 Horizontal Member Spans Upgraded Rafter Properties Overhang 0.99 ft Net W 3.50" Roof System Pro rties San 1 11.28 ft E aiv D 5.081, Number of Spans w/o Overhang) 1 Span 2 Nominal No Roofing Material Comp Roof Spain 3 A 17.80 In.A2 Re-Roof No Span 4 S,t 15.08 in.^3 Plywood Sheathing Yes Span 5 I 38.35 in.^4 Board Sheathing Solid-Sheathing Total Rake Span 14.47 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1''Start 0.67 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 10.83 ft Wood Grade #2 Rafter Slope 320 PV 2'Start Fb 875 psi Rafter Spacing 28"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loacling Summary Roof Pitch 8/12 In' ial Pitch Ad'ust Non-PV Areas PV Areas Roof Dead Load DL 12.5 psf x 1.18 14.7 psf 14.7 psf PV Dead Load PV-DL 3.0i sf x 1.18 3.5 psf Roof Live Load RLL 20.0 psf x 0.83 16.5 psf Live/Snow Load LL/SL 1,2 40.2 psf x 0.7 1 x 0.45 28.0 psf 18.0 psf Total Load(Governing LC TL 42.7 psf 36.3 sf Notes: 1. ps=Cs*pf;Cs-roof, Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)p9; Ce=0.9,Ct=1.1,I5=1.0 Member Design S mma (per NDS GoverningLoad Comb CD CL + CL - CF Cr D+ S 1.15 1.00 0.98 1 1.3 1 Member Analysis!Results Summary Governing Analysis Max Demand Ccb Location I Capacity DCR Result Bending + Stress 1058 psi 6.7 ft 1308 psi 0.81 Pass CALCULATION OF DESIGN WIND LOADS - MP1 & MP2 y Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 320 Rafter Spacing 28"O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standin Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height ht h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt) (Kd)(V^2)(I) Equation 6-15 16.7 psf Wind Pressure Ext. Pressure Coefficient(U ) GC,(ul)) -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC Down 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh (GC ) Equation 6-22 Wind Pressure Up RUM -15.8 psf Wind Pressure Down down 14.6 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 56" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 15 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -217 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 43.5% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 56" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 25 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -362 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 72.3% StRUCTURE ANALYSIS - LOADING SUMMARYI;,AND MEMBER CHECK - MP3 Member Proles Summary MP3 Horlzontal Member Spans Rafter Properties Overhang 0.66 ft Actual W 1.50" Roof System Properties S n 1 8.25 ft Actual D 5.50" Number of Spans w/o Overhan 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A 8.25 in,A2 Re-Roof No Span 4 SX 7.56 in.A3 Plywood Sheathing No S a s I 20.80 in.A4 Board Sheathing Solid-Sheathing Total Rake Span 9.22 ft TL DefPn Limit 120 Vaulted Ceiling No PV 1,'Start 0.83 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 7.50 ft Wood Grade #2 Rafter Slope 150 PV 2'Start Fb 875 psi Rafter Spacing 16" O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing I At Supports PV 3 End Emin 510000 psi Member Loa ing Summary Roof Pitch 3/12 In 'al Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 11.0 psf x 1.04 11.4 psf 11.4 psf PV Dead Load PV-DL 3.0` sf x 1.04 3.1 psf Roof Live Load RLL 20.0 psf x 1.00 20.0 psf Live/Snow Load LL SLl'Z 40.q psf x 0.7 1 x 0.7 28.0 psf 28.0 psf Total Load(Governing LC I TL 1 39.4 psf 42.5 psf Notes: 1. ps= Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(Ce)(CO(IS)Pg; Ce=0.9,Ct=1.1, I5=1.0 Member sign S mma er NDS Governing Load Comb CD I CL + CL - CF I Cr D+ S 1.15 1 1.00 1 0.78 1.3 1 1.15 Member Analysis Ntesults Summary Governing Analysis Max Demand 0 Lo4ation Capacity DCR Result Bending + Stress 752 psi 1 4.8 ft 1504 psi 1 0.50 Pass CALCULATION OF DESIGN WIND LOADS - MP3 Mountina Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 150 Rafter Spacing 16"O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standin Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h I 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor Kn 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 psf Wind Pressure Ext. Pressure Coefficient(Up) GC,(u -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down G Down 0.45 Fig.6-11B/G/D-14A/B Design Wind Pressure p p = qh (GC ) Equation 6-22 Wind Pressure U „ -13.1 psf Wind Pressure Down a W„ 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -197 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 39.4% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -246 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand Ca aci DCR 49.2% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. X91 DG *BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. GNC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE CITY OF NORTHAMPTON GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE BUILDING DEPARTMENT GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL These plans have been reviewed Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(6). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER And approved. kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN Date (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE Signature OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT I COVER SHEET 3R NEMA 3R, RAINTIGHT PV2 SITE PLAN I STRUCTURAL VIEWS PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) * * * * * * * * PREMISE OMNER: DESCRIPTION: DESIGN: CONTAINED AL — THE INFORMATION HEREIN JOB NUMBER: J B-0101734 00 STAWARZ, SARAH STAWARZ RESIDENCE Mike Baba CONTAINED SHALL NOT E USED FOR THE solarCity.BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 25 HINCKLEY ST 7.8 KW PV ARRAY �� PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: FLORENCE M A 0106 2 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-260PDO5.18 24 St.Martin Drive, Building 2,Unit 11 SOLARCIIY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE L 650 Marlborough, rlb r028h F:A(61752 638-1029 PERMISSION OF SOLARCITY INC. ISOLAREDGE SE760OA—US002SNR2 (413) 695-6382 COVER SHEET PV 12/12/2015 (ass>—soL�aTY��ss-24es� .,,w.ealar�ity.�arn PITCH: 32 ARRAY PITCH:32 MPI AZIMUTH: 166 ARRAY AZIMUTH: 166 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 35 ARRAY PITCH:35 MP2 AZIMUTH:346 ARRAY AZIMUTH:346 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 15 ARRAY PITCH:15 MP3 AZIMUTH:76 ARRAY AZIMUTH:76 MATERIAL: Comp Shingle STORY: 1 Story cn a� (E) DRIVEWAY Ln N AC O LEGEND D , (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS z b DC ZdW T� y id EEE DC DISCONNECT & WARNING LABELS AC Front Of House AC DISCONNECT & WARNING LABELS OB DC JUNCTION/COMBINER BOX & LABELS C DISTRIBUTION PANEL & LABELS LC LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER A STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L-�J SITE PLAN N Scale: 1/8" = 1' W E 0 1' 8' 16' S JB-01 01734 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED L— THE INFORMATION HEREIN JOB NUMBER: `\`!A SolarCity. CONTAINED SHALL NOT BE USED FOR THE STAWARZ, SARAH STAWARZ RESIDENCE Mike Baba , B IEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: w,,` 6R SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 25 HINCKLEY ST 7.8 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. FLORENCE, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-260PD05.18 SHEET: REV: DATE: Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME T: (650)638-1028 E: (650)638-1029 PERMISSION OF SOLARCISOLAREDGE SE7600A—US002SNR2 (413) 695-6382 SITE PLAN PV 2 12/12/2015 (8N)-SCI-CITY(765-2489) www.solarcity.com NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER U1 "t (E) WALL OR E RIDGE BOARD 2x6 SPF#2 (N SUPPORT BELOW _ ( ) MI OR SUPPORT BELOW MIN. �'-B f SIMPSON SDW SIMPSON SDW 22458 - S1 22300 WOOD WOOD SCREWS SCREWS (N) SISTER MEMBERS (E) RAFTER 4' 1' 11'-3 ,�, ,�,,,- „ ,,, ,// ,77 (E) LBW 4'-0"r n MIN. LENGTH rTMr' %ITMAi r\ ne Z NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDICATED BY HATCHING SEE MP SIDE VIEW FOR REQUIRED /-� UPGRADE NOTES: MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. D1 D1 LANDSCAPE 56" 1 24" STAGGERED 2. FASTEN (N) SISTER TO (E) MEMBER W/ SIMPSON SDW 22300 (IF 2-PLY) OR 22458 MIR PORTRAIT 56" 20" (IF 3—PLY) SDW SCREWS AS SHOWN AT 16. O.C. ALONG SPAN AS SPECIFIED, IF - RAFTER 2"x4-3/4"@ 28"OC ROOF AZI 166 PITCH 12 STORIES:2 C.I. 2"x43/4"@28"OC Com Shingle WOOD SPLITTING IS SEEN OR HEARD, PRE-DRILL WITH A :J' DRILL BIT. ARRAY AZI 166 PITCH sz ALT. OPTION FOR FULL LENGTH MEMBERS ONLY- FASTEN (N) SIDE MEMBER TO (E) RAFTER W/ 10d (IF 2-PLY) OR 16d FROM EACH SIDE (IF 3-PLY) COMMON NAILS AT 6. O.C. ALONG SPAN. J TOP VIEW OF PARTIAL LENGTH LAPPED SISTER •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED 1 Scale: 3/4"=1'-0" PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT 6" END ZEP ARRAY SKIRT (6) HOLE. DISTANCE 6 (4) CSEAL PILOT HOLE WITH " O.C. TYP.�' (E) 2x4 RAFTER 2)1 POLYURETHANE SEALANT. 1 ZEP COMP MOUNT C 4" ..... -b ._.._.. ZEP FLASHING C (3) — i (E) COMP. SHINGLE (4) PLACE MOUNT. SIMPSON SDW WOOD SCREWS (N) 2x6 SIDE MEMBER (E) ROOF DECKING (2) (5) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES (6) INSTALL LEVELING FOOT WITH WITHSEALING WASHER BOLT & WASHERS. Di 2x6 END FASTENER GROUPING (2-1/2" EMBED, MIN) 1 Scale: 1"=1'-0" (E) RAFTER STAN DOFF PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN NUMBER: JB-0101734 00 STAWARZ, SARAH STAWARZ RESIDENCE Mike Baba CONTAINED LL NOT E USED FOR THE �OI���'�� BENEFIT �- CANE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 25 HINCKLEY ST 7.8 KW PV ARRAY 0,� PART TO OTHERS OUTSIDE THE RECIPIENT'S: FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-260PD05.18 24 St Martin Drive, Building 2 Unit 11 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME ' REV` DATE: T. (650)836-1028 F:A(650)638-1029 PERMISSION Of SOLARCITY INC. ISOLAREDGE SE760OA-US002SNR2 (413) 695-6382 STRUCTURAL VIEWS PV 3 12/12/2015 (888)-SOL-CITY(765-2489) www.solarcity.com NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER U2 (E) WALL OR E RIDGE BOARD 2x6 SPF#2 (N) 4"t SUPPORT BELOW MIR - OR SUPPORT BELOW SIMPSON SDW SIMPSON SDW 22458 MIN. �'t 22300 WOOD WOOD SCREWS Sl SCREWS (N) SISTER MEMBERS (E) RAFTER 1' 10'-10" / '-0" MIN. (E) LBW � SEE MP SIDE VIEW FOR REQUIRED LENGT B SIDE VIEW OF MP2 NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDICATED BY HATCHING UPGRADE NOTES: D2 D2 MP2 IX-SPACINGIX-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. _ _ MIR LANDSCAPE 56" 24" STAGGERED 2. FASTEN (N) SISTER TO (E) MEMBER W/ SIMPSON SDW 22300 (IF 2—PLY) OR 22458 PORTRAIT 1 56" 20" (IF 3—PLY) SDW SCREWS AS SHOWN AT 16" O.C. ALONG SPAN AS SPECIFIED, IF RAFTER 2"x4-3/4"@ 28"OC ROOF AZI 346 PITCH 36 STORIES:2 WOOD SPLITTING IS SEEN OR HEARD, PRE—DRILL WITH A k" DRILL BIT. / ARRAY AZI 346 PITCH 35 ALT. OPTION FOR FULL LENGTH MEMBERS ONLY- FASTEN (N) SIDE MEMBER TO C.J. 2"x4-3/4"@28"OC Comp Shingle (E) RAFTER W/ 10d (IF 2—PLY) OR 16d FROM EACH SIDE (IF 3—PLY) COMMON U2 TOP VIEW OF PARTIAL LENGTH LAPPED SI TER NAILS AT 6" O.C. ALONG SPAN. •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED S1 6" END DISTANCE 4" �—�-6"�-16" O.C. TYP.----�' (E) 2x4 RAFTER 8 -3 1/ o a __ _... (E) LBW �— SIMPSON SDW WOOD SCREWS J (N) 2x6 SIDE MEMBER (:C )- SIDE VIEW OF MP3 NTS MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES D2 2x6 END FASTENER G ROU PI N G Scale: 1"=1'-0" LANDSCAPE 6411 24" STAGGERED PORTRAIT 4811 17" RAFTER 2x6 @ 16" OC ROOF AZI 76 PITCH 15 ARRAY AZI 76 PITCH 15 STORIES: 1 C.J. 2x4 @16" OC Comp Shingle JB-0101734 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: ���}p ■ CONTAINED SHALL NOT BE USED FOR THE STAWARZ, SARAH STAWARZ RESIDENCE Mike Baba ;SO�a�C�ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •"� y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 25 HINCKLEY ST 7.8 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES FLORENCE, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 17 THE SALE USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-260PDO5.18 : REV: DATE: 24 St. Martin rive, w Unit 11 PAGE NAME SHEET01 Marlborough, MA 01752 SOLARCITY MENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMISSION SOLARCIY INC. SOLAREDGE SE760OA—US002SNR2 (413) 695-6382 STRUCTURAL VIEWS PV 4 12/12/2015 (8N)-SOL-CITY(765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:G202OL1125 Inv 1: DC Ungrounded (3 0) #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:74184366 INV 1 —(1)SOLAREDGE# SE7600A—US002SNR� LABEL: A —(0)TRINA SOLAR TSM2360P PTC, ELEC 1136 MR Inverter; 7 00W, 240V, 97.5 ; w Unifed Disco and ZB, RGM, AFCI PV Module; OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V Overhead Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER—HAMMER fEGD 10OA/2P Disconnect 3 SOLAREDGE DC+ +SE760OA—US002SNR2 MP1: 1x16 C(E) LOADS A ----- L1 L2 I 1 � I 1 N DG I z I 40A/2P -------------—-----------—----------- - GEC/ --- DG lN - - MP2,MP3: 1x14 (II B GND __ EGC--- -----------—--------- ------------— G -------------- ---t� 1 �- I N I (1)Conduit Kit; 3/4" EMT o EGCIGEC_ z I I I I I 1 - GEC�— 1 TO 120/240V SINGLE PHASE I I UTILITY SERVICE I i I i PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP J (21)SIEMENS#Q240 PV BACKFEED BREAKER A (1)CUTLER—HAMMER i1!DG222URB n Pv OO)SOLAREDGE�300-2NA4AZS D� Breaker, 4OA/2P, 2 Spaces Disconnect; 60A, 24OVac, Non—Fusible, NEMA 3R /y PowerBox Optimizer, 30OW, H4, DC to DC, ZEP —(2)Gr qd RoQ —(1)CUTLER—CUTLER—HAMMER DG100NB 5�8 x 8, Copper Ground/Neutral Kit; 60-100A, General Duty(DG) nd (1)AWG /6, Solid Bare Copper —(1)Ground Rod; 5/8" x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE .... _.._._._ ____ _ -_._._ . _...__.. .. _._...__ __._.____—____.__ __ .. __ _.._....__._._ __ _. .______ __.._ . ....___ _ .___.. _....____ ___.. _. _ __ _.._ . 1 AWG 0, THWN-2, Black _ _ .. �_ _ O (1)AWG#8, THWN-2 Red J (2)AWG X10, PV Wire, 600V, Black Voc* =500 VDC Isc 15 ADC (1)AWG,#'10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=32 AAC O � (1)AWG 1)6, Solid Bare Copper EGC Vmp =350 VDC Imp=11.73 ADC (1 Conduit Kit. 3/4 EMT. . . . . . . . . . . . . . . .70)0!P 8,.TFIWN-2,.Green . . EGC/GEC.-(i)Conduit,Kit;.3/47,EMT . . . . . . . (2)AWG/10, PV Wire, 600V, Black Voc* =500 VDC Isc =15 ADC O (1)AWG,}6, Solid Bare Copper EGC Vmp =350 VDC Imp=10.26 ADC (1)Con04it Kit:.3/4' EMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-0101734 00 CONTAINED SHALL NOT BE USED FOR THE STAWARZ, SARAH STAWARZ RESIDENCE Mike Baba BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��,,SO�a�C�ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 25 HINCKLEY ST 7.8 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODUS FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH � THE SALE AND USE OF THE RESPECTIVE (30) TRINA SOLAR # TSM-260PDO5.18 1 24 SL Martin Drive,Building 2,Unit 11 MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME' REV' DATE T. (650)638 1028` F.( 650)638-1029 PERMISSION QF SOLARCITY INC. SOLAREDGE # SE760OA—US002SNR2 (413) 695-6382 THREE LINE DIAGRAM PV 5 12/12/2015 (888)-SOL-CITY(765-2489) vimsolarcity.cam CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 25 Hinckley St INVERTER AND DC DISCONNECT AC DISCONNECT r--I r I I Lr-- I I --------- I I I I r____ L_J i UTILITY SERVICE r--------------------------� SOLAR PHOTOVOLTAIC ARRAYS) L--------------------------J PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0101734-00 CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: J - B0101734 00 PREMISE OWNER: DESCRIPTION: DESIGN: — �\�!r ■� CONTAINED SHALL NOT BE USED FOR THE STAWARZ, SARAH STAWARZ RESIDENCE Mike Baba ` BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ",`�OI���' y® NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 25 HINCKLEY ST 7.8 KW PV ARRAY �,' PART TO.OTHERS OUTSIDE THE RECIPIENT'S MODULES FLORENCE, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE 30 TRINA SOLAR TSM-260PD05.18 4 t. Martinrlbb norougghhBuilding, MA 001 PAGE NAME: SHEET: REV: DAIE: Ma1Unit 1 752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN r�;LAREDGE TER: T: (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SE7600A—US002SNR2 (413) 695-6382 SITE PLAN PLACARD PV 6 12/12/2015 (888)—SOL-CITY(765-2489) www.solarcity.com WARNING:PHOTOVOLTAIC POWER SOURCE '• • • '• • • '' • • -- Code: UVARNI�JG -- .�-WARNING � Code: NEC 690.31.G.3 ELECTRIC'SHOCKiHAZARD ELECTRIC SHOCK HAZARD DO NOTT4UCH TERMINALS ••1 THE DC CONDUCTORS OF THIS 690.35(F) Label Location: TERMINALS QN BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN PHOTOVOLTAIC DC LOAD SIDES MAY BE ENERGIZED UNGROUNDED ANDINVERTERIS Per Code: •- IN THE OPEN POSITION MAY BE ENERGIZED UNGROUNDED NEC DISCONNECT •.1 Label Label • • PHOTOVOLTAIC POINT OF ■• INTERCONNECTION Per MAXIMUM POWER _A WARNING: ELECTRIC SHOCK ••_ POINT CURRENT(Imp) Per MAXIMUM POWER- Code: HAZARD. DO NOT TOUCHNEC • 1 690.54 POINT VOLTAGE(Vmp)-VNEC 690.53 TERMINALS.TERMINALS ON MAXIMUM SYSTEM BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc) V MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE SHORT-CIRCUIT-A DE-ENERGIZE BOTH SOURCE CURRENT(Isc) AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT - MAXIMUM AC Label Location: OPERATING VOLTAGE - V WARNING ' Per ..- ELECTRIC SHOCK HAZARD 690.5(C)•1 IF A GROUND FAULT tS INDICATED NORMALLY GROUNDEDLabel L• _ • UNGROUNDDEDOAND ENERGIZED CAUTION (POI) POWER SOURCEPer Code: SECOND SOURCE IS 690.64.13.4 PHOTOVOLTAIC SYSTEM Label • • WARNING Per Code: '._ ELECTRICAL SHOCK HAZARD • • DO NOT TOUCH TERMINALSNEC 690.17(4) CAUTION ' -• TERMINALS ON BOTH LINE AND Per Code: LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFEDNEC 690.64.13.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNING '• Per Label INVERTER OUTPUT Location: CONNECTION 690.64.B.7 AC -• (AC): AC Disconne - ••' THIS ODEV�ERRENTConduit NEC .•1 DistributionPanel Conduit(DC): DC Disconnect Label Location: (IC): Interior Run (INV): Inverter With -. -. MAXIMUM AC - A -• Load OPERATING CURRENT DC Disconnect Code: Meter MAXIMUM AC OPERATING VOLTAGE V ••1 54 (M): Utility-• Point of • • 3055 Clearview Way San Mateo,CA 1 1 M 1 '• 1' v 1 • 1 1 1 LabelSet T:(650)638-1028 F:(650)638-1029 • N '''t$Oli3fCltY ZepSolar Next-Level PV Mounting Technology "'^$OlarCity ZepSolar \ Next-Level PV Mounting Technology Components Zep System for composition shingle roofs ' `l p-rff Leveling Foot „e C+ratrrW Zep .. =xrg u9n;rr� r Part No.850-1172 ETL listed to UL 467 , n �� PIMn III,„ 1 Zep c4mpawAe Pt Module ,y 4 t Rnot Attachment Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 ,004l� �I N �°e� Description UY PV mounting solution for composition shingle roofs FA Works with all Zep Compatible Modules °ofaPa��e Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip IJP LISTED Part No.850-1388 Part No.850-1511 Part No.850-1448 Specifications Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" %k6l • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt, Grip, End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM • solar=ee solar=@a SolarEdge Power Optimizer Module Add-On for North America P300 I P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America (tor 60-cell PV (for 72-cell PV (for 96-cell PV modules) modules) modules) P300 / P350 l P400 • INPUT Rated Input DC Power'i 300 350 400 W Absolute Maximum Input Voltage Ivor,at lowest temperature) 48 60 80 Vdc 1a �td 1'r, L t ,y�.y MPPI"Operating Range 8-48 8-60 8-80 Vdc I Maximum Short Circuit Current Qsc) 10 Adc .rs, y < a ��'�' P Maximum DC Input Current 12.5 Adc Tr 1 � ' Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % = SR�,v € Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _. sh`k"i 3 as ° ® Maximum Output Current 15 .. Adc e9 I 1„z111 4. Maximum Output Voltage _- - - 60 _. Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output_Voltage per Power Opt'mizer 1 Vdc . STANDARD COMPLIANCE FMC FCC Part15 Class 8,IEC61000-6-2,IEC61000 63 r Safety IEC62109 1(class II safety),UL1741 OW RoHS Yes INSTALLATION SPECIFICATIONS �., -, ". Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H) ' 141x212 x40.5/S.SSx8.34x 1.59 mm/in .' Weight(including cables) 950/2.1 gr/!b Input Connector MC4/Amphenol/Tyco Output Wire Type/Connector Double Insulated;Amphenol Output Wire Length 0.95/3.0 1.2/3.9 m/it Operating Temperature Range -40-+85/-40-+185 - Protection Rating IP65/NEMA4 Relative Humidity 0-100 % -=t -1d sip ,or memd,de.Mo 1w of w IR-5xp—, a1wd PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V PV poW£C Dpi:im Ization at the module-!(veli Minimum String Length(Power Optimizers) ..... 8 _--. -_-. 10 _.18 - Up to 25%more energy Maximum String Length(Power Optimizers) 25 25 50 l, Maximum Power per String 5250 6000 12750 W '., s Superior Csff)<IeACy(99,5%) Parallel Strings of Different Lengths or Orientations yes Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading_ - Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module level monitoring = Module-)eve)voltageshutdown for Installer and firefighter safety CE ON .S .aP _.,,... .,_r .I. ,._, s,.,,� s a d;;E? us �1 t /ut ate L-. E 05.E Mono Multi Solutions DIMENSIONS OF PV MODULE ELEGTRICAl. Y'A;c STC unii:rnfn Peak Power Watts-P.-(Wp) 245 250 255 260 941 -- - -- --- Power Output Tolerance-Pro 1%) 0-+3 Maximum Power Voltage-VMP(V) 29.9 30.3 30.5 30.6 1-C i. a sox Maximum Power Current-IMVP(A) 8.20 8.27 8.37 8.50 THE TKna 1 1 NAMEPLATE l Open Circuit Voltage-Vac(V) 37.8 38.0 38.1 38.2 I O 409i1� Short Circuit Current-14c(A) 18.75 8.79 8.88 9.00 mnnuiNG nope Module Efficiency qm(%) 15.0 15.3 15.6 15.9 STC:Irradiance 1000 W/m',Cell Temperature 25"C,Air Mass AM1.5 according to EN 60904-3. (D" D U L E Typical efficiency reduction of 4,5%at 200 W/m'according to EN 60904-1. La o _ 'O o ELECTRICAi,'DA`A-',:NOCT Maximum Power-P-(Wp) 182 186 190 '.. 193 60 CELL Maximum Power Vol(Y) 27.6 28.0 28.1 28.3 MULTI\rft I JTAI.LINEMODULE -4.3G-NDIN-E Maximum Power Current-IMPP(A) 6.59 6.65 6.74 6.84 A A iaoaaNNOLe Open Circuit Volta„ e{Y}-Voc{V) 35i 353 35.3 354 WITH TRiNAM©UNT FRAME Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 7.27 NOCT:Irradiance a1800 W/nI Ambient Temperature 20°C,Wind Speed I m/s. PD05.18 Stz so Backview POWER OUTPUT RANGE Sola MECHANICAL DATA Solar cells Muliicrystalline 156 x 156 mm(6 inches) Fast and simple to install through drop in mounting solo ior), Cell orientation 60 cells(6 K lo) 1 Module dimensions 1650 x 992 x 40 mm(64.95 x 3905 x 1.57 inches) 0 � Weight 21.3 kg(47,0 lbs) - - MAXIMUM EFFICIENCYA-A Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass BackO.eet White Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamouni Groove __ ..___. 7-V CURVES OF Pit MODULE{2d5i1} J Box 1P 65 orIP 67roted IMhi � Cables Photovoltaic Technology cable 4.0 mm2(0.006 inches'), __..._... _........... __...... __......... ............. ._....._..... .__........... .. ""�� 1pm_ _. -._ _- -_ _- 1200 mm(47.2 inches) POWER OUTPUT GUARANTEEUSCOW/m= Fire Rating Type 8� 800W/m' Highly reliable due to stringent quality control C? a 4.°1 40OW/mn - - TF.0,PEREa=t'sRE'ATINGS MAXIMUM TiA=1NGS 3.- zaow/ Nominal Operating Cell (±2-C) Operational Temperature -40-+85°C kdu,c-, e ^tom- � - - 2� �- '-' Temperature(NOCT) 44°CMaximum System 1000V DC(lEC) J.`i CIjl'» T 11 1`s i ......... ......... _...... ....._..... _ o.� -- - Temperature Coefficient of Fw x O.dl%/°C Voltage i 1000Y QC(Ul) :h p m 10.`tl 201° 30'. 40.00 ..(C.._ r-,,,..>L,sd the,..tt-.-'_ =I i-. Voltage(V) Temperature Coefficient of Vcc -0.32%/°C Max Series Fuse Rating 15A I ,7 E t;ter, 1 Temperature Coefficient of Ise 0.05%/°C F"�Ii .�t n,,t Certified to withstand challenging en ironm too conditions fi el products,<< to IIt ,: e,..ctck ;1, - I;,00 is.,t c r. 7 7 Kr"�f 2'.._, F �,L.«:� WARRANTY _r� _eta 10 year Product Workmanship Warranty 11 �IL rrIJ*. 25 year Linear Power Warranty Cir 6.,.4 a Colkabcra lon r (). (Please refer to product warranty for details) d T paIrtiv1r)(; oI CERTIFICATION LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION € � c PN - - - -- - 10 Year Product Warranty• 5 Year Linear Poorer Warranty us,m D Modules per box:26 pieces z Tema Solar Limited w' !► wiiiiiii X Modules per 40'container:728 pieces f ,n 3,• - ;l00%ft%**6Z 90°6CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USINGTHEPRODUCTQqo Specifications - �: a ©2014 Trina Soler L mited.All rights reserved. included in this da}asheet are subject to „�® Trin-aZ"t t 9" l2 80% la change w thoutnotice. / W «?L j Smarr feicY Years 5 0 15 20 25 �r �T-TfT?T �AOOWN ` o moue L Mono Multi Solutions THE DIMENSIONS Of PV MODULE EiEC`RICA€.DATA�&STC unU:mm Peak Power Watts-PMA.(Wp) 250 255 260 265 941.-__ -- Power Output Tolerance PMA,c{%) 0-+3 THE Maximum Power Voltage VMP(V) 30.3 30.5 30.6 30.8 r i na o unt o ,uNawN o eox Maximum Power Current IMPP(A) 8.27 8.37 8.50: 8.61 NAMEPLATE 'o Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 38.3 HSTniiTNG eoLe Short Circuit Current-Isc(A) 8.79 8.889.00. 9.10 S Module Efficiency rIm(%) 15.3 15.6 15.9 16.2 MODULE STC:Irradiance 1000 W/m',Cell Temperature 25-C,Air Mass AM1.5 according to EN 60904-3. Typical efficiency reduction of 4.5%a1200 W/m'according to EN 60904-I, 0 b � O E EC:RICAk DATA,a NOCT 60 CELL■ � Maximum Power PMAx(WP) 186 190 193 197 1 (b\rill L �tl� Maximum Power Voltage-VMP(V)'. 28:0 28.1 28.3 28.4 MULTICRYSTALLINE MODULE '"" - Maximum Power Current-IMPP(A) 6.65 6.74 6.84 6.93 68 a 3 GPDUNDING NIXE WITH TRINAMOUNT FRAME PD05.18 u.DxAIN wLE ? ? Open Circuit Voltage(V)-Vo(:(V)' 35.2 35.3 35.4 35.5 Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 NOCT:Irradiance at 800 W/m2,Ambient Temperature 2000,Wind Speed I m/s. �--- 250- 6812 - 180 � Back View ,'vtECypp1,CAL DATA POWER OUTPUT RANGE Solar cells Multicrystalline 156 x 156 mm(6 inches) Fast and simple to install through drop in daunting solution cell orientation 60 cells(6 x 10) Module dimensions 1650 x 992 x 40 mm(64.95 x 39-05 x 1.57 inches) 1 6.2 Weight 19.6 lag[4112 lbs) ■■■■ Glass 3.2 mm(0.13 inc hes).Hlgh Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY Backsheet whits .�. A-A .. Frame Black Anodized Aluminium Alloy Good aesthetics for residential talieol�ar� J-Box W65 or IF 67 rated '- ' Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), Om-+347a, 1200 mm(47.2 inches) ............. ___._.... .____ ...... .._........ __.....___.._ ._.._. .._.. ........._. .........._ ____- I=V CURVES OF PV MODULE(Z60W� POSITIVE POWER TOLERANCE ,o.00 Connector; H4Amphenol'' soo ! 1°0D'^'/'"' ---- Fire Type UL 1703 Type 2 for Solar City Highly reliable clue to stringent duality control 1e 7 3 l.,r Too s - ttr t1C°;'S TEMPERAT RERA.IN MAXIMUMRATINGS U `GS Pff orNominal Operating Cell Operational Temperature 40-+85°C 0tl C,n xr I ' r ;C r, aoo - Temperature(NOCT) ;1- Maximum System 1000V DC(IE ftCf Temperature Coefficient of P.. 0.41%/°C Voltage 1090V OC(UL} ri .... _..... ...__ _...._.... ihc,globe; l Temperature Coefficient of Voc 0.32%/°C Max Series Fuse Rating 15A G;P ,... , o00 -- .yam a.h orkci Certified to withstandchallenging environmental o 0 20 00 4o so Temperature Coefficient oflsc 0.05%/°C l . . :, tori itions vorc,"M 'tF si WARRANry' CERTIFICATION 10 year Product Workmanship Warranty 't "A� 25 year Linear Power warranty C '« (,+.,�J('S II C c�V6 ��• (Please refer to product warranty for details) Q LJ, :t ^ Y LIN EAR PERFORMANCE WARRmANTY.. �a I EU-28WEEE i ICN lON zCOMPLIANTLCi Warranty 25 {r 13h'CC Power Warranty Modules Per box.26 pieces Solar Limited _ _ Modules per 40'container 728 pieces a AtyG'1##015Qf 1''C77Lte _ _.... p 90% oe Tr°rraSoiar's6rnear ® 6 /CItCi7R$1r ® CAUTION'READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. "OMPATjB Trinasola3 {� ¢^ change without notice All rights reserved Specifications Included In this doosheet aresubject to = l7 80% 2. soled ©2015 Trina Solar Limited ri hi .S e ' ryQO`� an e ;;:,art nptt �,. N d;:<..1t::r;er - A Years 5 10 IS 20 25 OOMPP~� solar - Single Phase Inverters for North America 'r SE300OA-US/SE380OA-IJS/SE500OA-LJS f SE6000A-US! solar=@@ SE7600A-US;SEt0000A-1US/SE11400A-US - -------- ------- __ SE3000A-US .SE380OA-US SESOOOA US SE60GOA-US; SE760OA-US SE10000A US SE1140OA US OUTPUT SolarEdge Single Phase Inverters Nominal A(:Power Output 3000 3800 5000 6000 7600 9980@2080 11400I VA 10000 @240V Max.AC Power Output 3300 4150 5400 @ 2080 6000 8350 10800 @ 2080 12000 VA For North America AC Output Voltage Min.-Nom.Max 121 5450 @2400 10950 @2400 183-208-229 Vac SE300OA-US 1 SE380OA-US/SE500OA-US SE600OA- S/ AC Output Voltage Min.-Nom Maxl'I 211-240-264 Vac '2 ✓ ✓ ✓ SE760OA-US/SE10000A-US1SE1140DA- AC FrequencyMin:Nom:Max1�1 59.3-60 60.5(with Fllcountry setting 57 60 60.5) liz �-�% �^` Al n Max.Continuous Output Current 12.5 16 @ 208V 24 @ 2080 2S 32 42 2400 4L5 A gam'/ 21 @ 2400 A ` y ,3.., �� �� etzlr f GFDIThreshold 1 `�'t '� Ufility Monitoring,Islanding Protection,Country Configurable 1"hresholds._.,. _ _ Yes.... __— ..Yes .- � INPUT Maximum DC Power(S"C) 4050 5100 6750 8100 10250 13500.... _1.5350 W Transformer-less,Ungrounded Yes se Max.Input Voltage Soo Vdc 325 v 208V 350 @ 240V Nom.DC Input Voltage � / Vdc r' t f 16.5 @ 208V 33 @ 2080 ` Max.Input Current"' 9.5 13 18 23 345 Adc 155 @ 2400 _ 30.5 @ 240V a� .✓ Max.Input Short Circuit Current _ Ad" Ye Reverse-Polarity Protection Yes Ground-Fault isolation DetectionJfw 50Ck+aSensltivrty i �., / Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 48 98 98 MY 97.5 @ 2080 97 @ 208V CEC Weighted Efficiency 97.5 98 g8 @ 2400 97.5 97.5 97.5 @ 2400 97.5 f .. .._. ........ _........... ,.._..... ...._ ......— ...__ Nighttime Power Consumption = _ _. , .<2.5 .._. zy _ ..,...._ ... _ - :' ADDITIONAL FEATURES - - ," � Supported Communication Interfaces _ RS485,RS232,Ethernet,ZlgBee(optional) r Optional1, Revenue Grade Data,ANSI C121 _ _. ........ Rapid Shutdown-NEC 2074 690.52 FvncYonall y enabled when SolarEdge rapid shutdown kit Is Installedl0j__ 'M STANDARD COMPLIANCE - — JL17 2.2 SA 2 _ necr on Standards Safety � 41,UL 699B UL1998 C " Grid Con IEEE1547 FCC part Emissions __ __... ,,. ..,.. ..... ..._. .....,. ....... B .- .. _. _._. .. 15 class INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum%8-3 AWG DC input conduit size/#of strings/ 3/4"minimum/1-2 strings{ 3/4"minimum/1-2 strings/16-6 AWG 14-5 AWG AWG range „. _ Dimensions with Safety Switch30.5 x 12.5 x 10 5/ m J 1%: r (HxVJxD) 304x12.5z72J775x315x 184 775x315x 260 mm Weight with Safety Switch 51,2/23.2 54.7/24.7 88.4/40.1 Ib/kg Natural convection and internal Cooling Natural Convection Fans(user replaceable) fan(user _ replaceable) #,� t - - T -, be c e�ar 'e ena ytem _ Noise <2S <50 dBA Jllgf ' - 'fai ^Ctr4teGtli €ff (}1 1 .. Yn( 1Ce = Min.-Max.Operating Temperature -13 to 4140/-25 to+60(�O to+60 version availablelsl) 'F/"C Range "Slrior effii nCy� $o} - - Protection Rating NEMA 3R ^ S'i'rFSII, tuve' t and to in$tall{ir3 prpVlded bracket - in For other reg onal semngs please contact SolarEdge support. Built-in ` 131 A h[gher current source may be used,the'nverter will -t t input current to the values stated. Buiit'ln module-level monitoring 131 Revenue grade inverter P/N SExxxxA US000NNR2(for 760OW-nverter SE7600A US002NNR2). ♦ vr. Id1 Rapid shutdown kit P/N SE1000 RSD Sl Internet connection'.through Ethernet or ireles Isl ve son P/N SExzxxA USOOONNU4(for 7600W inverter SE7600A U5002NNU41. 40 Outdoor and indoor.installation Fixed voltage inverter,DC/AG conversion only — Pre-assembled Safety Switch for faster installation - Optional-revenue grade data,ANSI C12A c • ..SR M AN -ffIY 1iAiN r_.[- A P,>.i C.-i.:4h ,^. - V�.-`<AUA ..1 NF l DS TR_AN . RAwww.solaredge.us `ZL_ V cit t .SOIarPC2. 15