Loading...
38A-103 (11) `VA 1 ;}. nU FIRE PROTEC'T'ION SYSTEM NARRATIVE 780 CMR 903.1.1 FOR VCA. INC 209 EARCT STREET NORTHAMPTON, MA BY SIEGFRIED FORTH ARCHITECT 1 16 PLEASANT STREET EASTHAMPTON, MA 413-529-9434 903.1.1 La ] BASIS [ METHODOLOGY ] of" 1 11L;SIGN SECTION 1 - BUILDING DF;SCRIP"TION THE BUILDING IS A 20,000 S.FT. ONE STORY FINE WOODWORKING FACILITY WITH ATTACHED OFFICE. THE" BUILDING WILL BE DESIGNED AS MIXED USE NON-SEPARATED SECTION 313.1.1 NON S'E'PARATED USE GROUPS: EACH PORTION OF THE BUILDING SHALL, BE INDIVIDUALLY CLASSIFIED AS TO USE. THE REQUIRED TYPE OF CONSTRUCTION FOR THE BUILDING SHALL BE DETERMINED BY APPLYING THE HEIGHT AND AREA LIMITATIONS FOR EACH OF THE APPLICABLE USE GROUPS TO"IL;[: ENTIRF; BUILDING. THE MOST RESTRICTIVE TYPE OF CONSTRUCTION SO DETERMINED SHALL APTLY. THE OTHER REQUIREMENTS OF 780 CMR SHALL APPLY TO EACH PORTION OF THE BUILDING BASED ON THE USE GROUP OF THAT OCCUPANCY EXCEPT THAT THE MOST RESTRICTIVE APPLICABLE PROVISIONS OF 780 CMR 403.0 HIGH RISE BUILDINGS ! NOT APPLICABLE J AND 780 CMR CHAPTER 91 NON APPLICABLE]- SHALL APPLY TO THESE NON SEPARATED USE GROUPS. A FIRE SEPARATION ASSEMBLY IS NOT REQUIRED BETWEEN USE GROUPS, EXCEPT AS REQUIRED BY OTHER SECTIONS OF 780 CMR. a] BUILDING USE GROUP: F-1 MODERATE HAZARD STORAGE IS THE MOST RESTRICTIVE USE GROUP bl "TOTAL SQUARE FOOTAGE OF BUILDING: 20,307 SQ. FT. TABLE 503—HEIGHT AND,AREA LIMITATIONS OF BUILDINGS USE: F-1, TYPE OF CONSTRUCTION: 2C ALLOWABLE IS: 2 STORY, 30' HIGH, 9,600 SQ. FT. SECTION 506.3 AREA INCREASE DUE TO AUTOMATIC SPRINKLER SYSTEM IF THE BUILDING IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM AS PER SECTION 906.2.1 THE REQUIREMENTS OF`]-ABLE 503 MAY BE INCREASED BY 200% 9,600 S.F ALLOWABLE X 200% = 19,200 S.FT INCREASE THEREFORE: 9,600+ 19,200=28,800 SQ. FT. BUILDING IS ALLOWED. WE HAVE A TOTAL OF 20,307 SQ. FT. ]STORY ,22' HIGH I OKI C] BUILDING HEIGH'I: 22'-0" LAVE HEIGHT d] NUMBER OF FLOORS ABOVE GRADE: ONE [I] e] NUMBER OF FLOORS BELOW GRADE: ZERO [0] L] SQUARE FOOTAGE PER FLOOR: 20,307 SQ. FT. g] TYPE OF OCCUPANCY WITHIN THE BUILDING: B AND F-I h] TYPE OF CONSTRUCTION: 2C UNPROT CTED i] HAZARDOUS MATERIALS: H-2 COMBUSTIBLE DUST. SECTION 307.8[l I EXEMPT AMOUNTS I POUND PER 1,000 CU. FT. MAX. ----15,736 S.FT. X 21' = 372,456 CU. FT./1,000 372 POUNDS OF DUST ALLOWABLE. J] HIGH STORAGE: N/A kj SITE ACCESS: A 24' WIDL DRIVEWAY DIRECTLY OF OFF EARLS ST. SECTION - 2 APPLICABLE' LAWS, REGULATIONS. AND STANDARDS a] 780 CMR CODE SECTIONS" FIRE PROTF,C11ON SYSTEM REQUIREMENTS" SECTION 904 FIRE SUPPRESSION SYSTEMS. REQUIRED IN USE GROUP F-I IN BUILDINGS OF 12,000 S.FT. OR GREA"LER 1N AGGREGATE FLOOR AREA AN AUTOMATIC SPRINKI,l-JZ SYS7FFM IS REQUIRFD AS PER SECTION 906.2.1 1 NFPA131 n SECTION 906.5 SPRINKLER ALARMS APPROVED AUDIBLE AND VISUAL ALARM DEVICES SHALL BE CONNECTED TO EVERY WATER SPRINKLER SYSTEM. IN ACCORDANCE WITH NFPA 72 C] SECTION 917 FIRE PROTECTIVE SIGNALING SYSTEM PULL STATIONS - NOT REQUIRED d] SECTION 918 AUTOMATIC FIRE DETECTION SYSTEMS NOT REQUIRED C] SECTION 920.0 FIRE EXTINGUISHERS SHALL BE INSTALLED IN USE GROUP F-I S-1 1N ACCORDANCE WITH NFIPA-10 i� NFPA STANDARDS AND FDI !-IONS USED FOR Fill"' DESIGN OF EACH SPECIFIC FIRE PROTECTION SYSTEM. NfiPA 33 AND 34 g] TABLE 602: FIRE RESISTANCE RATINGS OF STRUCTURE ELEMENTS TYPE 2C UNPROTECTED—EXTERIOR WALLS-LOAD BEARING—0 HOURS REQUIRED h] TABLE 507.2: MINIMUM FIRE RESISTANCE RATING OF EXTERIOR WALLS USE GROUP F-1 —70 FEET OR GREATER SECTION-4 FIRE PRO"i ECTION SYSTI?MS TO 13L INSTALLED aJ AUTOMATIC DIRE EXTINGUISHING SYSTEM 780CMR 419.0 APPLICATION OF FLAMMABLE FINISHES 419.1 GENERAL: ALL SUCH EQUIPMENT SHALL COMPLY WITH NFIPA 33 AND 34 419 2.1 SPRAY BOOTHS ALL SPRAY BOOTHS SHALL BE CONSTRUCTED OF APPROVED NONCOM BUSTTBLE MATERIALS AND EQUIPPED WI I'll MECFIANICAL VENTILATION SYSTEMS IN ACCORDANCE W1"I'II THE MECHANICAL CODE. CHAPTER 10 MEANS OF EGRESS: OCCUPANCY LOADS: TABLE 1008 1 2 MAIN FLOOR USE GROUP AREA SQ 1-7,T],RSON _ MAX.#OF PEOPLE B 2,545 100 26 F-1 17.762 300 59 TOTAL 85 TOTAL POPULATION CAPACITY OF EGRESS DOORS: TABLE 1009.2 MAIN FLOOR 2" PER PERSON IS REQUIRED 85 PEOPLE X 2"— 17" 2—36" DOORS ARE REQUIRED. WE HAVE THREE EGRESS DOORS I OK11 LENGTH OF EXIT ACCESS TRAVEL: TABLE 1006.5 USE GROUP B 250 MAX. W/ SPRINKLER SYS7F-_M USE GROUPS F-1 -=250' MAX. W'SPRINKLER SYSTEM OUR LONGEST DISTANCE BFT1i/EEN EXITS ISAPPROXIMATELY 190' DIVIDED BY TWO EQUALS 85" AS THE MAX DISTANCE;OF TRAVEL TO AN EXIT. OK