Loading...
38A-090 (4) �w 0)Y&e-,ol c/- YaA+ u%p -Tool_TZp 4,and Y&ndmc& THOMAS GATZUNIS ®npia«n��uACCd�- �oom�7907 Chairmen JANE SWIFT KENTARO TSUTSUMI Governor QjJ_,/ _ /J,,_ _ _/K_. _/�E. O2'08 vice Chairman JAMES JA]UGA e/V 'Gww s\ avlc`4vlZAI LO�f[4' THOMAS L.ROGERS Secretary " ' Administrator y'if 1'7)727-7532 FAX:(617)227-1754 April 29, 2002 Avis America Henry Street—P. O. Box 420 Avis,PA. 17721 RE: RE-CERTIFICATION IN THE MASSACHUSETTS MANUFACTURED BUILDINGS PROGRAM MC#027 To Whom It May Concern: This letter is to confirm your re-certification in the Massachusetts Manufactured Buildings Program as a producer of Manufactured Buildings has been approved for the period May 1, 2002 through April 30, 2003. This approval is contingent upon compliance with all previously listed conditions of your approval and compliance with the provisions of 780 CMR the Massachusetts State Building Code 6"'Edition,the Electrical Code and Fuel/Gas Code. Sincerely, _STATE BOARD OF BUILDING REGULATIONS AND STANDARDS 'Phomas L. Roger Administrator cc: MA. Board of Examiners of Plumbers and Gas Fitters APPROVED 'MA.- Board of Examiners of Electricians ?0102 LFA�,TOP hUVAL ;;4 i3 " BL POFkA► t.. This correspondence has been issued from the Board of Building Regulations and Standards g Taunton district office: 1380 Bay Street, P.O. Box 871, Taunton, MA 02780 Permit Number MECcheck Compliance Report Checked By/Date Massachusetts Energy Code MECcheck Software Version 3.3 Release lb Data filename:J:\Shane\HS-HARRITY 7 MASCHECK.cck TITLE:HARRITY 7 CITY:Florida STATE:Massachusetts HDD: 7658 CONSTRUCTION TYPE: 1 or 2 Family,Detached HEATING SYSTEM TYPE: Other(Non-Electric Resistance) DATE:09/12/02 DATE OF PLANS: 8-8-02 PROJECT INFORMATION: THE HOME STORE P.O.BOX 300 WHATELY MA 10193 COMPANY INFORMATION: AVIS AMERICA P.O.BOX 420 HENRY ST AVIS PA 17721 NOTES: HARRITY 7 GROVE ST. FLORENCE MA COMPLIANCE:Passes Maximum UA=278 Your Home=254 8.6%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 825 30.0 0.0 29 Wall 1:Wood Frame,24"o.c. 1955 19.0 0.0 100 Window 1: Vinyl Frame,Double Pane 172 0.370 64 Door 1:Glass 41 0.390 16 Door 2: Solid 44 0.140 6 Floor 1:All-Wood Joist/Truss,Over Unconditioned Space 825 19.0 0.0 39 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed buildin as be_e_ikftr, `D - t HIP A 7 NN' A;PPPiOVA,L w E1) TO FACTORY BUILT PORTION r to meet the Massachusetts Energy Code requirements in MECcheck Version 3.3 Release lb and to comply with the mandatory requirements listed in the MECcheck Inspection Checklist. The heating load for this building,and the cooling load if appropriate,has been determined using the applicable Standard Design Conditions found in the Code. The HVAC equipment selected to heat or cool the building shall be no greater than 125%of the design load as specified in Sections 780CMR 1310 and J4.4. Builder/Designer Date �142LC3 i APPROVED L �/,c1fAL ll4l�iEEO TO Y BUILT PORTION MECcheck Inspection Checklist Massachusetts Energy Code MECcheck Software Version 3.3 Release lb DATE:09/12/02 TITLE: HARRITY 7 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] I. Wall 1:Wood Frame,24"o.c.,R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame,Double Pane,U-factor:0.370 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ] Yes [ ]No Comments: Doors: ( ] 1. Door 1: Glass,U-factor:0.390 #Panes Frame Type Thermal Break? [ ] Yes [ ]No Comments: [ ] 2. Door 2: Solid,U-factor: 0.140 Comments: Floors: [ ] 1. Floor 1:All-Wood Joist/Truss,Over Unconditioned Space,R-19.0 cavity insulation Comments: Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] When installed in the building envelope,recessed lighting fixtures shall meet one of the following requirements: 1. Type IC rated,manufactured with no penetrations between the inside of the recessed fixture and ceiling cavity and sealed or gasketed to prevent air leakage into the unconditioned space. 2. Type IC rated,in accordance with Standard ASTM E 283,with no more than 2.0 cfm(0.944 L/s)air movement from the the conditioned space to the ceiling cavity. The lighting fixture shall have been tested at 75 PA or 1.57 lbs/ft2 pressure difference and shall be labeled. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] ( Materials and equipment must be identified so that compliance can be determined. [ ) Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans ifications. APPROVED Pr,, nr7p SEP 1. 7 2p02 FA .OR1 i11L PORTION F Duct Insulation: [ ] ( Ducts shall be insulated per Table J4.4.7.1. Duct Construction: [ ] All accessible joints,seams,and connections of supply and return ductwork located outside conditioned space,including stud bays or joist cavities/spaces used to transport air,shall be sealed using mastic and fibrous backing tape installed according to the manufacturer's installation instructions. Mesh tape may be omitted where gaps are less than 1/8 inch. Duct tape is not permitted. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Heating and Cooling Equipment Sizing: [ ] Rated output capacity of the heating/cooling system is not greater than 125%of the design load as specified in Sections 780CMR 1310 and J4.4. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 120°F or chilled fluids below 55 OF must be insulated to the levels in Table 2. APPRPPS. r OVcQ SEF 1 7 2002 / PPHUVAL �. ; 1Z � TO FACTOH'Y SUlLT POR JOt4 r Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) APPROVED L SEP 1 7 200' APPRUVAt, „w, i ;0 T JFACTOrR,Y B1.lii_T r°O1'sutK�1,�