April 29, 2002
Avis America
Henry Street—P. O. Box 420
Avis,PA. 17721
RE: RE-CERTIFICATION IN THE MASSACHUSETTS MANUFACTURED
BUILDINGS PROGRAM MC#027
To Whom It May Concern:
This letter is to confirm your re-certification in the Massachusetts Manufactured Buildings
Program as a producer of Manufactured Buildings has been approved for the period May 1, 2002
through April 30, 2003.
This approval is contingent upon compliance with all previously listed conditions of your
approval and compliance with the provisions of 780 CMR the Massachusetts State Building
Code 6"'Edition,the Electrical Code and Fuel/Gas Code.
Sincerely,
_STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
'Phomas L. Roger
Administrator
cc: MA. Board of Examiners of Plumbers and Gas Fitters APPROVED
'MA.- Board of Examiners of Electricians
?0102
LFA�,TOP
hUVAL ;;4 i3
" BL
POFkA► t..
This correspondence has been issued from the Board of Building Regulations and Standards
g Taunton district office: 1380 Bay Street, P.O. Box 871, Taunton, MA 02780
Permit Number
MECcheck Compliance Report Checked By/Date
Massachusetts Energy Code
MECcheck Software Version 3.3 Release lb
Data filename:J:\Shane\HS-HARRITY 7 MASCHECK.cck
TITLE:HARRITY 7
CITY:Florida
STATE:Massachusetts
HDD: 7658
CONSTRUCTION TYPE: 1 or 2 Family,Detached
HEATING SYSTEM TYPE: Other(Non-Electric Resistance)
DATE:09/12/02
DATE OF PLANS: 8-8-02
PROJECT INFORMATION:
THE HOME STORE
P.O.BOX 300
WHATELY MA 10193
COMPANY INFORMATION:
AVIS AMERICA
P.O.BOX 420 HENRY ST
AVIS PA 17721
NOTES:
HARRITY 7
GROVE ST.
FLORENCE MA
COMPLIANCE:Passes
Maximum UA=278
Your Home=254
8.6%Better Than Code
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 825 30.0 0.0 29
Wall 1:Wood Frame,24"o.c. 1955 19.0 0.0 100
Window 1: Vinyl Frame,Double Pane 172 0.370 64
Door 1:Glass 41 0.390 16
Door 2: Solid 44 0.140 6
Floor 1:All-Wood Joist/Truss,Over Unconditioned Space 825 19.0 0.0 39
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications,and other calculations submitted with the permit application. The proposed buildin as be_e_ikftr, `D -
t
HIP A 7 NN'
A;PPPiOVA,L w E1) TO
FACTORY BUILT PORTION
r
to meet the Massachusetts Energy Code requirements in MECcheck Version 3.3 Release lb and to comply with the
mandatory requirements listed in the MECcheck Inspection Checklist.
The heating load for this building,and the cooling load if appropriate,has been determined using the applicable
Standard Design Conditions found in the Code. The HVAC equipment selected to heat or cool the building shall be no
greater than 125%of the design load as specified in Sections 780CMR 1310 and J4.4.
Builder/Designer Date �142LC3
i
APPROVED
L
�/,c1fAL ll4l�iEEO TO
Y BUILT PORTION
MECcheck Inspection Checklist
Massachusetts Energy Code
MECcheck Software Version 3.3 Release lb
DATE:09/12/02
TITLE: HARRITY 7
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:
Above-Grade Walls:
[ ]
I. Wall 1:Wood Frame,24"o.c.,R-19.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Vinyl Frame,Double Pane,U-factor:0.370
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ] Yes [ ]No
Comments:
Doors:
( ] 1. Door 1: Glass,U-factor:0.390
#Panes Frame Type Thermal Break? [ ] Yes [ ]No
Comments:
[ ] 2. Door 2: Solid,U-factor: 0.140
Comments:
Floors:
[ ] 1. Floor 1:All-Wood Joist/Truss,Over Unconditioned Space,R-19.0 cavity insulation
Comments:
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] When installed in the building envelope,recessed lighting fixtures
shall meet one of the following requirements:
1. Type IC rated,manufactured with no penetrations between the inside of the recessed fixture
and ceiling cavity and sealed or gasketed to prevent air leakage into the unconditioned space.
2. Type IC rated,in accordance with Standard ASTM E 283,with no more than 2.0 cfm(0.944
L/s)air movement from the the conditioned space to the ceiling cavity. The lighting fixture
shall have been tested at 75 PA or 1.57 lbs/ft2 pressure difference and shall be labeled.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ ] ( Materials and equipment must be identified so that compliance can be determined.
[ ) Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans ifications.
APPROVED
Pr,, nr7p
SEP 1. 7 2p02
FA .OR1 i11L PORTION
F
Duct Insulation:
[ ] ( Ducts shall be insulated per Table J4.4.7.1.
Duct Construction:
[ ] All accessible joints,seams,and connections of supply and return ductwork located outside
conditioned space,including stud bays or joist cavities/spaces used to transport air,shall be sealed
using mastic and fibrous backing tape installed according to the manufacturer's installation
instructions. Mesh tape may be omitted where gaps are less than 1/8 inch. Duct tape is not permitted.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Heating and Cooling Equipment Sizing:
[ ] Rated output capacity of the heating/cooling system is not greater than 125%of the design load as
specified in Sections 780CMR 1310 and J4.4.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 120°F or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
APPRPPS. r
OVcQ
SEF 1 7 2002
/ PPHUVAL �. ; 1Z � TO
FACTOH'Y SUlLT POR
JOt4
r
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD(Building Department Use Only)
APPROVED
L
SEP 1 7 200'
APPRUVAt, „w, i ;0 T
JFACTOrR,Y B1.lii_T r°O1'sutK�1,�