Loading...
24C-049 25 WOODLAWN AVE BP-2016-1006 GIs#: COMMONWEALTH OF MASSACHUSETTS Map.Block: 24C-049 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-1006 Project# JS-2016-001700 Est. Cost: $25000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq. ft.): 43995.60 Owner: HAHN KENNETH zoning: URA(100)/ Applicant: SOLARCITY CORP AT. 25 WOODLAWN AVE Applicant Address: Phone: Insurance: 604 SILVER ST (978)215-2369 () Workers Compensation AGAWAMMA01001 ISSUED ON.•211112016 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 9.88 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 2/11/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2016-1006 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (978)215-2369 Q PROPERTY LOCATION 25 WOODLAWN AVE MAP 24C PARCEL 049 001 ZONE URA(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid 140u Building Permit Filled out -� Fee Paid Typeof Construction: INSTALL ROOF MOUNTED 9.88 KW SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOAMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management D Wa re uiIding fficial' Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. l �pertrttfill� City of Northampton It "! ullding Department 212 Main StreetNil Room 100 FEB , u o ampton, MA 01060 y �P 3-5 7-1240 Fax 413-587-1272 APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 25 Woodlawn Ave. Map Lor unit Zone Overlay District Elm St.District CS District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Kenneth Hahn 25 Woodlawn Ave.Northampton, MA 01060 Name(Print) Current Mailing Address: 413-221-5202 Telephone Signature 2.2 Authorized Agent: SolarCity CorpNictoria Junck 604 Silver St Agawam MA 01001 Name(Prim; Current Mailing Address: r �y 978-215-2367 Sig et re Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 7,000 (a)Building Permit Fee 2. Electrical 18,000 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=0 +2+3+4+5) 25,000 Check Number #77 15 to a 75 This Section For=Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date 14xvl-�- r� � Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding[ ] Other❑✓ Brief Description of Proposed Work: Install solar electric panels to roof of existing home,to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet tea.If Flew Ouse an Qr ad ion to existina housina, 6ompiete t e-f l Win a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Kenneth Hahn as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 02/09/2016 Signature of Owner Date SOLARCITY CORPNICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY C0RPN1CTqR1,A JUNCK Print Name 'l-A'l-7 �.� 02/09/2016 4, atur-e'urC5w­ner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Address Expiration Date 978-875-1698 Signature Telephone 9.Reaistered Hm-91moromeMaM.Contractor. Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2017 Address .- _ Expiration Date Telephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11 - 11W1e doer Exempt on The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature The Commonwealth of Massachusetts 4 � t ,Department of IndustrialAcciclents Office Of Investigatious 716'r 1 1 Congress Street,Suite 100 ' Boston,A14 02114-2017 www.mass*gov/dia Workers'Compensation Insurance Affidavit: Buildelrs/Coe>ttractorsAElectridans/Plulmbers Applicant Inform tion Please Priest Legibly Name(ausineWOrganizationlindividual): SOLARC[TY CORP Address:3055 CI.EARVIEW WAY City/State/Zip:SAN MATEO, CA 94402 Phone#:888-765-2489 Are you an employer?Check the appropriate box: Type of project(required): IM I am a employer with 5000 4. ❑ I ain a general contractor and 1 6. ❑New construction ctrtployces(full and/or part-time),* have hired the sub-contractors 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. [ Remodeling ship and have no employees These sub-contractors have 8. (]Demolition workingfor me in an capacity. employees and have workers' Y9. ❑ Building addition [No workers' comp.insurance comp. insurance.t We are a corporation and its 10.0 Electrical repairs or additions required5. .] ❑ 3.❑ I am a homeowner doing al work officers have exercised their I I.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MG1.. 12.❑Roof repairs insurance required.]t c. 152,§1(4),and we have no SOS/PV employees. [No workers' 13.-Other comp. insurance required.] *Arty applicant that cheep box#1 must stso fill omt llic seciian below showing their workcrs'compensation policy infestation. t tlomtowacts who submit this affidavit indicating they are doing all wad.and then hire oulside contoctors must submit a new affidavit indicating such. toontractors that check this box must attached an additional aticet showing the name or the sub-contractors and state whether or not those entities havc employees. Irthe sub-wntraclors have employees,they must provide tlieir wotl�crs'camp.policy number. I a►n an employer float is providing workers'compensation im;u"rance for my employedc. Below O the palicv azul f ab site Information. Insurance Company Name: Zurich American Insurance Company Policy It or self-ins. Lic. #-.._WC0182014-00_ Expiration Date: 09/01/2016 Job Site Address: �; Zo x aL'o'n City/State/xip:.M,t tlC ,jZ $l r' 0610 Attach a copy or the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a S'T'OP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I rto hereby certify hailer the palms rind penaltles of perfur tlfat floe tr{Torntafiurt provided above is true and correct. 318t�attirry: t��" 6 — _. '�.'�"� t`•,�..:.... ..� �?iS�t. -phone# O elal use only. Do not write in this area,to be completed by city or tower official. City or Town: Permittaicense# Issuing Authority(circle one): I.Rom or Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector S.Plumbing Inspector 6.Other Contact Person: _— Phone#: ® DAVE(MMIDOIYYYY) A►�Ra' CERTIFICATE OF LIABILITY INSURANCE 08117/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS � CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(fes)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CONTACT PRODUCER -POMlr;......,... .. ....... T................. ................................... ..... MARSH RISK& INSURANCE SERVICES PHONE FAx 345 CALIFORNIA STREET,SUITE 1300 (ALC.Pio_ExtY ............ .. CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 DRISS-;................... ........... ._... .... ......._... . .. .. ........... .._.... . .... .. .......... ....... COVERAGE Attw Shannon Scott 415.743.8334 tNSURE�S)AFpaRDINc 998301•STNO-GAINUE-15-16 .,,,.-, _,...-.INsuRER-a:Zuflch Ameican Insurance Company 16535 INSURED INSURER B:NIA 'NIA SolarCity Corporation idlA.. . ._.._.—. 3055 Claalview Way INSURER C:NIA __. . San Mateo,CA 94402 INSURER D:American Zurich insurance Company 40142 _...............—... _..__.......__....... .... ..... . ........_...... ._ INSURER E. ..._.................. ......_ INSURER F COVERAGES CERTIFICATE NUMBER: SEA-002713836-08 REVISION NUMSER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTE FF R TYPE OFINSURANCE .._.......... ADOt.SUER....... .. ..AOLICY NUMBER ..._—.� PNt10DlYYYY�MiOItJ➢IYYYY�—._—._—. LIMITS A { X '.COMMERCIAL GENERAL LIABILITY IGLO0182016-00 09/01I2015 !0910112016 EACH OCCURRENCE S 3,600,000 ....)CLAIMS-MADE !.R,. OCCUR ? .FREMI.WS,{fe occurrence)-.......'�'..... ................3�.. . ..... XSIR:$250,006 _ � MED.a<xP{Aw.enc pe 5n) . S..._...... . 5,oaa .... ........... _ I PERSC1NAt&ADV INJURY s 3;000,066 GEN'L AGGREGATE LIMIT APPLIES PER- GENERAL AGGREGATE S 6,000,000 ............. AAO- I ' PRODUCTS-GOMPIOPAGG $ 6,000,000 X POLICY L.. . JECT 1.....j LOC .; }PRODUCTS _............ ...f.._... .... OTHER: I 13 COMBINED SINGLE LIMtT A AUTOMOBILE LIABILITY t3AP6182017.00 09101/21115 10910112015 S 5,000,000 ila.aEcldanti..... 1 BODILYINJURY(Per persdn) $ X ANY AUTO I X ALL OWNED X SCHEDULED k BODILY INJURY .Y..(.P...e.r.a..c.c..d.e.n.t. } S AUTOS AUTOS ED PROPERTYD4dAGE $ HIREDAUTOS AUTOS .X ...... ....... _..... . .._... .... j coMPrcaLL DED: S $5,606 UMBRELLA LIAS I OCCUR ! EACH OCCURRENCE .....-. ...... .. .. ... .. D.E.._..T . .. CLAIMS-MADEI AGGREGATEEXCESS LIAB .. D rRETENTIONS .... ..,....tS•... ..... ................ I S D WORKERS COMPENSATION WC0182014-00(AOS) 09011201509-0112016 X f PER OTFI- AND EMPLOYERS'LIABILITY I �.....i.S'rATVIE-.t.._. �R......6...... ....... .. ................ A ANY PROPRtETORIPARTNER7EXECUTIVE Y 1 N WC6182a15•Qa(MA) 09;0112015 69101/2016 E.L.EACH ACCIDENT $ 1,atia,ao6 OFFICERlMEMBER EXCIUOED7 �WA1.............AS . ..I... 1,000,000 {Mandatory In NH) NC AEDUCTIBLE:5506,000 E.L.DISEASE-EA EMPLOYE 5 If yes.describe under ....... .... ..... ............. !DESCRIPTION OFOPERATIONS below ! E.L.DISEASE PLG LtM1T S 1,Q60,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES{ACORO S IN,Addltionai Remarks Schedule,may to attached R more space Is requlredl Evidence of insuranea. CERTIFICATE HOLDER CANCELLATION SoiarCily Corporatron SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearview Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Maleo,CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk a Insuranco Services Charles Martnolejo 1 ®1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:70BE5535-711F-47B7-9064-759720C1A038 SolarCityI PPA Customer Name and Address Installation Location Date KENNETH HAHN 25 Woodlawn Avenue 1/21/2016 Northampton,MA 01060 25 Woodlawn Avenue Northampton,MA 01060 Here are the key terms of your Power Purchase Agreement JL AV 50 AV SH 170; 1 2 Gk mrs System installation cast Electricity fat lcy4ih AgreemeTrn Initial hire initial hee The SolarCity Promise DS •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. ...... ___ Initial here •We warrant all of our roofing work. DS •We restore your roof at the end of the Agreement. •We warrant, insure, maintain and repair the System. ._.... ..-_ . . . ... ........ -._._..... Initial here •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will remain fixed for the term of the Agreem+ont: •The pricing in this Agreement is valid for 30 days after 1/21/2016. Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: •At certain times,as specified in $0 •SolarCity,will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 •You can upgrade to a new System with .These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est.amount due at building inspection contract. not beyond that term. •You may purchase the System from Est.first year production SolarCity for its fair market value as 9,105 kWh specified in the Agreement. .You may renew this Agreement for up to ten(10)years in two(2)five(5)year increments. 3055 Clearview Way, San Mateo, CA 94402 1 888.765.2489 1 solarcity.com 1x07364 Power Purchase Agreement,version 9.1.0,November 11,2015 SAPC/SEFA Compliant Contractors License MA HIC 168572/EL-1136MR Document generated on 1/21/2016 �R1 Copyright 2008-2015 SolarCity Corporation,All Rights Reserved �V DocuSign Envelope ID:70BE5535-711F-47B7-9064-759720C1A038 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:KENNETH HAHN EXPLANATION OF THIS RIGHT. Fc� by: 24. ADDITIONAL RIGHTS TO CANCEL. Im H(Oj IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL Signature: I C� C�ItC� THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL THIS PPA AT NO COST AT ANY TIME PRIOR TO Date: 1/21/2016 COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after 1/21/2016. Customer's Name: If you don't sign this PPA and return it to us on or prior to 30 days after 1/21/2016,SolarCity reserves the right to reject this PPA unless you agree to our then current pricing. Signature: Date: Power Purchase Agreement SolarCity approved Signature: Lyndon Rive, CEO Date: 1/21/2016 Mpre,,, nt, c,i 3 ,u. ,!'�Vemb:ar 0=5 � � 1 Version#53.6-TBD SolarCity. February 8, 2016 RE: CERTIFICATION LETTER Project/Job # 0101867 Project Address: Hahn Residence 25 Woodlawn Avenue Northampton, MA 01060 AHJ Northampton SC Office Springfield Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 90 mph, Exposure Category C -Ground Snow Load =40 psf - MPI: Roof DL = 10.5 psf, Roof LL/SL= 21.6 psf(Non-PV Areas), Roof LL/SL= 11.6 psf(PV Areas) - MP2: Roof DL = 10.5 psf, Roof LL/SL = 21.6 psf(Non-PV Areas), Roof LL/SL= 11.6 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22462 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluationI certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. F Sincerely, O� K Digitally signed by HKariuki .2 R,UKI Humphrey ngi, P.E. Date: 2016.02.08 14:48:58 ° sNO.193 CTuRAL Professionall Engineer T: 443.451.3515 -QS'QQ' ��FG)sTE�O email: hkariuki@solarcity.com S`S10NAL s(hEa C Ir�irviev�4�J<<ti San U)tf�0 CA 9.}.1(}2 T,b 10)(33 8 10:18 o988)tit_)L-(;ITY F Iti 0 Ei;iB Version#53.6-TBb SolarCity. HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI 64" 24" 39" NA Staggered 45.0% MP2 64" 24" 39" NA Staggered 45.0% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI 64" 20" 65" NA Staggered 74.8% MP2 64" 20" 65" NA Staggered 74.8% Structure Mounting Plane Framing Qualification Results type Spacing Pitch Member Evaluation Results MPI Stick Frame @ 16 in.O.C. 451 Member Impact Check OK MP2 Stick Frame @ 16 in.O.C. 450 Member Impact Check OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. i1.,,:i Glearuie=et ,V,1r `;,j I) M.31I iO, GA 9-.1<<(l; T ti6`10G.S€i " � i1;ur3� `.SOL-(Il Y r(W,D)63'' 11;29 It"it VsJon� l STRUCTURE ANALYSIS - LOADING SUMMARY;AND MEMBER CHECK- MP1 Member Prorties Summary MPi Hoiizontal Member Spans Rafter Properties Overhang 0.66 ft Actual W 1.50" Roof SVstem Prwoperties Sp4n 1 11.22 ft Actual D 7.25" Number of Spans w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof S n 3 A 10.88 1n.^2 Re-Roof No Span 4 S. 13.14 in A3 Plywood Sheathing Yes SpAn 5 I 47.63 in.^4 Board Sheathing None Total Rake Span 16.80 ft TL DefPn Limit 120 Vaulted Ceiling No PV 1 rt 0.50 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 16.00 ft Wood Grade #2 Rafter Sloe 450 PV 2:VUrt Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 rt E 1400000 psi Bot Lat Bracing At Supports PV 3 End E.in 510000 psi Member Loa4ing Summary Roof Pitch 12/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.5 psf x 1.41 14.8 psf 14.8 psf PV Dead Load PV-DL 3.0 Ipsf x 1.41 4.2 psf Roof Live Load RLL 20.0 psf x 0.60 12.0 psf Live/Snow Load LL/Sl.1,2 40.0.psf x 0.54 1 x 0.29 21.6 psf 11.6 psf Total Load(Governing LC I TL 1 36.4 psf 1 30.7 psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)p9; Ce=0.9,Ct=1.1, I,=1.0 Member Design S'mma (per NDS Governing Load Comb CD CL +) CL CF Cr D+ S 1.151 1. 0 0.39 1.2 1.15 Member Analysis esults summary Governing Analysis I Pre-PV Demand I i I Post-PV Demand Net Impact I Result Gravity Loading Check 694 psi 1 583 psi 0.84 1 Pass CALCULATION OF DESIGN WIND LOADS - MPI Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 450 Rafter Spacing 16"O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 WindDesign Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor KA 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 Psf Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down G pout 0.88 Fig.6-11B/CJD-14A/B Design Wind Pressure p p = qh(GC) Equation 6-22 Wind Pressure U „ -14.2 Psf Wind Pressure Down 13.1 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -225 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 45.0% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 64" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 29 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual 374 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 74.8% 1 STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP2 Member Proporties Summary MP2 Ho ontal Member Spans Rafter Propertles Overhang 0.66 ft Actual W 1.50" Roof System PrWoperties 5 n 1 11.22 ft Actual D 7.25" Number of Spans w o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof S n 3 A 10.88 in A2 Re-Roof No San 4 S. 13.14 in A3 Plywood Sheathing Yes S n 5 I 47.63 in.^4 Board Sheathing None Total Rake Span 16.80 ft TL DefTn Limit 120 Vaulted Ceiling No PV 1' rt 0.50 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 15.92 ft Wood Grade #2 Rafter Sloe 450 PV 2 rt Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F. 135 psi Top Lat Bracing Full PV 3',rSkart E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loa ing Summary Roof Pitch 12/12 In 'al Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 10.5 psf x 1.41 14.8 psf 14.8 psf PV Dead Load PV-DL 3.0 11 Psf x 1.41 4.2 sf Roof Live Load RLL 20.0 psf x 0.60 12.0 psf Live/Snow Load LL SL1,2 40.q psf x 0.54 1 x 0.29 21.6 psf 11.6 psf Total Load(Governing LC I TL 1 1 36.4 psf 1 30.7 sF Notes: 1, ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2, pf=0.7(Ce)(Ct)(IS)pg; Ce=0.9,Ct=1.1, I5=1.0 Member Design q1. 0 mma (per NDS GoverningLoad Comb CD C + Cl. - CF Cr D+ S 1.15 0.39 1 1.2 1.15 Member Analysis iResults Summary Governing Analysis Pre-PV Demand I I Post-PV Demand Net Impact Result Gravity Loading Check 694 psi 1 583 psi 0.84 Pass CALCULATION OF DESIGN WIND LOADS - MP2 Mountina Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 450 Rafter Spacing 16"O.C. Framing Type/Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA ,Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor KA 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 Psf Wind Pressure Ext. Pressure Coefficient U GC -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC o W„ 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure U „ -14.2 psf Wind Pressure Down 13.1 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -225 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 45.0°% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 64" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 29 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -374 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 74.8% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTER11ED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN ECC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING CITY O F NORTHAMPTON EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, LL BE PRVIDED GALLV GA VANIZEDFSB FIRE SET—BACK HAZIARDSn PER ART.O690.17 WARNING OF THE BUILDING DEPARTMENT GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. These plans h ave been revseWed I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). And approved. Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC D ate r 6 LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. Signature NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Northampton REV BY DATE COMMENTS REV A DWM 2/8/16 Added modules to Northern MP on garage UTILITY: National Grid USA (Massachusetts Electric) CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JB-0101867 00 HAHN, KENNETH HAHN RESIDENCE Daniel Meehan SolarCity. BENEFlT�ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'„ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 25 WOODLAWN AVENUE 9.88 KW PV ARRAY PART IZ OTHERSEXCEPT IOUTSIDE ON RECIPIENTS WT MODULES: N O R TH A M P TO N MA 01060 ORGANIZATION, EXCEPT IN CONNECTION WITH � 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (38) TRINA SOLAR # TSM-260PD05.18 PAGE NAME: SHEET: REV DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTENFS1901LAREDGE �: T. (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SE10000A—USOOOSNR2 (413) 221-5202 COVER SHEET PV 1 a 2/8/2016 (BBB)-SOL-CITY(765-2469) www.Worcity.com PITCH: 45 ARRAY PITCH:45 MP1 AZIMUTH:227 ARRAY AZIMUTH: 227 MATERIAL: Comp Shingle STORY: 1 Story B [cill m _ REV A a o (E)DRIVEWAY o _ Inv =77 3 L0 C EESN - M M MP F H I O K. A `T oR1u1<I � v S UCTURAL No.51933 �FGIST ELEGEND ONAL (E) UTILITY METER & WARNING LABEL STAMPED & SIGNED FOR STRUCTURAL LY Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS B © DC DISCONNECT & WARNING LABELS Digitally signed by © AC DISCONNECT & WARNING LABELS Front Of House H Ka ri u ki O DC JUNCTION/COMBINER BOX & LABELS Date: 2016.02.08 p DISTRIBUTION PANEL & LABELS 14:40:41 -OS�OO� Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L-J SITE PLAN Scale:1/16" = 1' 01' 16' 32' JB -0101867 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT USED FOR THE HAHN, KENNETH HAHN RESIDENCE Daniel Meehan �:,;So�arCity. BENEFIT OF ANYONE EXCEPT SOLARCIIY INC., MOUNTING SYSTEM: ��.� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 25 WOODLAWN AVENUE 9.88 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTHAMPTON MA 01060 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (38) TRINA SOLAR # TSM-260PD05.18 SHEET: REV: DATE: Malborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARgTY INC. SOLAREDGE SE10000A—US000SNR2 (413) 221-5202 SITE PLAN PV 2 a 2/s/2o1s (BBB)-SGL-CITY(765-2489) www.solarcity.com v S1 4" 11'-3" (E) LBW A SIDE VIEW OF MP1 NTS MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 2411 STAGGERED �P PORTRAIT 64" 20" K. y'1S Ki RAFTER 2X8 @ 16" OC ROOF AZI 227 PITCH 45 STORIES: 1 0 C;TU ARRAY AZI 227 PITCH 45 V ST UGTURAL C.J. 2X12 @16"OC I Comp Shingle NO.51933 �COO S 1 GIST STAMPED & SIGNED 4" FOR STRUCTURAL ONLY (E) LBW B SIDE VIEW OF MP2 NTS MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED PORTRAIT 64" 20" RAFTER 2X8 @ 16 OC ROOF AZI 47 PITCH 45 ARRAY AZI 47 PITCH 45 STORIES: 1 C.J. 2x12 @16"OC Comp Shingle PREMISE OMNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN loe NUMBER: JB-0101867 00 HAHN, KENNETH HAHN RESIDENCE Daniel Meehan �\` SolarCit CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Vii,` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 25 WOODLAWN AVENUE 9.88 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S P ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES NORTHAMPTON, MA 01060 THE SALE AND USE OF THE RESPECTIVE (38) TRINA SOLAR # TSM-260PDO5.18 1 24 St. Marta,Drive,Building Z Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV. DATE: MarlbT. (650)63807028,638—o1028F: 52 638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE1000OA—USOOOSNR2 (413) 221-5202 STRUCTURAL VIEWS PV 3 a 2/8/2016 (888)-SCI-CITY(765-2469) .,ww.sclarcitYcom O K. O R►UKt U ST uCTURAL NO,51933 O RFGIST£�� SS10NA1. PV MODULE STAMPED & SIGNED 5/16" BOLT WITH LOCK INSTALLATION ORDER FOR STRUCTLJRAL Y & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. SEAL PILOT HOLE WITH (4) (2) POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. I (1) (E) ROOF DECKING (2) F INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) C(5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF J B-0101867 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: �\`!s ■ CONTAINED SHALL NOT BE USED FOR THE HAHN, KENNETH HAHN RESIDENCE Daniel Meehan �:,;So�arCity. BENEFIT IT BEE EXCEPT DISCLOSED IN WHRCITY OLE ORCINISOLAREDGE MOUNTING SYSTEM: 25 WOODLAWN AVENUE 9.88 KW PV ARRAY �,���� PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: NORTHAMPTON, MA 01060 24 St. Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (38) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME SHEET: REV: DATE: Marlborough,MA 01752 SOLARCITY EOUIPMENT, WITHOUT THE WRITTENINVERTER: T. (650)638-1028 F: (650)636-1029 PERMISSION OF SOLARCITY INC. SE1000OA—USOOOSNR2 (413) 221-5202 UPLIFT CALCULATIONS PV 4 a 2/8/2016 (686)-SOL—CITY(765-2469) www.solarcitycom ELECTRICAL CALCULATIONS String and 2 Combined Strings Module Type: Module Count: Icont = (Amps): TRINA SOLAR # TSM-260PDO5.18 38 15 Branch Circuit Individual MPPT 1 strings per Branch A strings per Branch B 19 modules per series string modules per series string String Branch A Branch B Conductor: Conductor: Conductor: (cont * 1.25 = (Amps) 15 18.75 30 deg C ampacity = 40 40 PV Wire Size: AWG #10 AWG #10 (cont = (Amps) 15 15 Start ampacity 40 40 Temperature derate (%=F) 0.76 0.76 Conduit fill derate (%_#) 1 0.8 Derated ampacity 30.4 24.32 (cont * 1.25 = (Amps) 15 18.75 Ampacity 40 40 Inverter Output Inverter Type: Inverter Count: Total SolarEdge 10000 AFCI RGM 1 (cont = (Amps): 42 (cont * 1.25 = (Amps) 52.5 OCP Size = 60 Conductor 3: AWG #6 THWN-2 (cont * 1.25 = (Amps) 52.5 30 deg C ampacity = 75 (cont = (Amps) 42 Start ampacity 75 Temperature derate (%=F) 0.91 Conduit fill derate (%=#) 1 Derated ampacity 68.25 (cont * 1.25 = (Amps) 52.5 Ampacity 65 NUMBER: CONJB-0101867 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN ,106 `\ !A CONTAINED SHALL NOT BEE USED FOR THE HAHN, KENNETH HAHN RESIDENCE Daniel Meehan ..;,;SO�a�C�ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.,, y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 25 WOODLAWN AVENUE 9.88 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTSORGMODULES: NORTHAMPTON MA 01060 THE ASALE AND USE OF INIZATION, EXCEPT CONNECTION RESPECTIVE�TM (38) TRINA SOLAR # TSM-260PD05.18 24 St. Martin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV DATE: L• (650) ,MA 01752 638-1026 : (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE10000A—USOOOSNR2 (413) 221-5202 ELECTRICAL LOAD CALCULATIONS 1�1L1dCal¢s 2/8/2016 (BBB)—SOL-CITY(765-2489) www.Warcity.aam CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 25 Woodlawn Avenue AC DISCONNECT INVERTER AND DC DISCONNECT r El C SCONNECT UTILITY SERVICE SOLAR PHOTOVOLTAIC ARRAYS) L--------------------------J PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN FAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0101867-00 JB-0101867 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: . CONFIDENTIAL — THE INFORMATION HEREIN IDB NUMBER: HAHN, KENNETH HAHN RESIDENCE `\,��SolarCit . CONTAINED SHALL NOT BE USED FOR THE Daniel Meehan 4h BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .,; Y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 25 WOODLAWN AVENUE 9.88 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES:- NORTHAMPTON M A 01060 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Math Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (38) TRINA SOLAR # TSM-260PD05.18 PAGE NAME: SHEET: REV DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMISSIONOF SOLARCITY INC. SOLAREDGE SE10000A—US000SNR2 (413) 221-5202 SITE PLAN PLACARD PV 6 a 2/8/2016 1 (8B8)-SOL-CITY(765-2489) www.edacity.com PHOTOVOLTAIC,® -SOURCE Label Location: Label Location: Label Location: WARNI NG: (C)(CB) ® (AC)(POI) WARNING (DC) (INV) Per Code: ® ♦_■ Per Code: ELECTRIC SHOCK HAZARD Per Code: NEC 690.31.G.3 ■® • ^ • NEC 690.17.E THE ■ CONDUCTORS • THISNEC 690.35(F) Label Location: PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC (DC) (INV) ••® ■ ■ -° ■ ■ • ■ INVERTER IS •- -• • BE ENERGIZED DISCONNECT Per Code: UNGROUNDED NEC 690.14.C.2 Label Location: II II Label Location: PHOTOVOLTAIC,V -• • (POI) POINT I MAXIMUM CURRENT POWER-I 'l (DC) (INV) INTERCONNECTION Per Code: SHOCKWARNING: ELECTRIC Per Code: HAZARD. ■. NOT TOUCHNEC 690.17.4; NEC 690.54 MAXIMUM.• VOLTAGEPOWER- NEC 690.53 • BOTH THE LINE AND LOAD SIDE MAXIMUM VOLTAGE ! POSITISERVICE OOR •- ■ BOTH SOURCE e ■ MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING MAXIMUM AC V Label Location: OPERATING VOLTAGE WARNING (DC) (INV) Per Code: IF A GROUND ELECTRIC SHOCKFAULT IS HAZARD® ■ NEC 690.5(C) NORMALLY -• . ■ Label Location: CONDUCTORS (POI) UNGROUNDED • ■ ■ DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.B.4 PHOTOVOLTAIC Label Location: ♦ ® (DC) (CB) HAZARDELECTRICAL CK Per Code: Label Location: ■• • ® • NEC 690.17(4) ♦ (D) (POI) TERMINALS ON BOTH- ■ Per Code: LOAD sibEs•_ POSITIONEN PHOTOVOLTAIC SYSTEM IN THE ■ NEC 690.64.B.4 DC VOLTAGE IS ALWAYS SOLAR •■ ARE EXPOSED TO SUNLIGHT Label Location: ♦ ® (POI) _ Per Code: INVERTEOUTPUT Label Location: CONNECTIO NEC 690.64.B.7 PHOTOVOLTAIC AC (AC) (POI) ■• NOT RELOCATE (AC): AC Disconnect DISCONNECT Per Code: THIS ® -■ (C): Conduit EVICE NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUMV • (AC) (POI) (LC): Load Center •• CURRENT Per Code: (M): Utility Meter •,ERING • NEC 690.54 (POI): Point of Interconnection LTAGE CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `�► 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �■. San Mateo,CA 94402 29 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set �lr�l. -SOL-)638-10-2 89)w) .solar i EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE If'SolarCultv. (888)-SOL-CITY(765-2489)wwwsolarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. r SolarCity ®pSolar Next-Level PV Mounting Technology 'ij,,SolarCity ®pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs n l t 'z XVLeveling Foot50 q! � .;I I t�rwrb zap Intettoak °� Part No.850-1172 ETL listed to UL 467 r� I UP compatla PV Modula zap®rome �I Roof Attaahmsnt .. ABY SW �t11 r'il Comp Mount Part No.850-1382 8 Listed to UL 2582 t, Mounting Block Listed to UL 2703 OOMPgT�Qr/ ADescription� PV mounting solution for composition shingle roofsWorks with all Zep Compatible Modules Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip uL LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, 8 zepsolar.com zepsolar.com sited to UL 67 ULL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM • solar=vs Solar=qg SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 ! P400 Module Add-On For North America (for60 PV (for 72-cell PV (for 96-cell PV modules) modules) modules) INPUT P300 / P350 / P400 • Rated Input DC Poweri'� 300 350 400 1 W Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 1Vdc MPPT Operating Range 8-48 8-60 8-80 Vdc o Max mum Short CircuitCurrent llsc) 10 -.,,.,, -,.,,,,, Adc .., ... . ._.. ._. ._ ....._ _.. Maximum DC Input Current 12 5 Adc ,s Maximum Efficient 99.5 - % Weighted Efficiency Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current 15 Adc - Maximum Output Voltage_ 60 Vdc K ... ...._ ...__ ._._ 11111111111"I'll, _.__ ___.._ _ _.. s, ;" • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) _ — ----- _Safety Output Voltage per Power Optimizer 1 ) Vdc : ., STANDARD COMPLIANCE EMC FCC Part15 Class B,IE061000-6-2,IEC61000 6-3 Safety IEC62109-1(class II safety),UL1741 .. ROHS Yes -^f - INSTALLATION SPECIFICATIONS „ Maximum Allowed System Voltage 1000 Vdc Dimensions(W ZLx H) - 141x 212x 40.5/555x8.34x159 i mm/in Weight(including cables) 950/21 9r/lb* Input Connector MC4/Amphenol/Tyco Output Wire Type/Connector Double Insulated;Amphenol Output Wire Length 095/30 12/39 m/ft s` Operating Temperature Range 40 +85/40 +185.. I 'C/°F-- v ✓?/ / Protection Rating IP65/NEMA4 Relative Humidity 0-100 ' >' na�a sn oo.o o c moa�o moe�i�o o sx oo.omo,a�«a o " PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE : THREE PHASE SINGLE PHASE IA4NVER SER ring Length(Power Optimizers) — 8 - 200V 980V _ P W4i fy hini2ation at t t114M t �tfxf -' _ _.. I7to 259 [ 'energy = _ __ _ Maximum String Length(Power Optimizers) 25 25 50 Maximum Power per String Parallel Strings of Different Lengths or Ori 5250 6000 12750 W u)ertior a�Y V x.59&} _ .. . _ _ __.._ _... giffengthOrien*aeons Yes *• Mitigates alf types'oi"h utlVEe m stnatC#1 o orrt manufactttr rag kalera to {iatshading _..__.. ........ _....... _ _..__.._ ._ _.._ Flexible system design foo atdmutrt e t aeton Fast installation with a slrtgla bolt i- Next generation maintenance with module-level monitoring Module-levet voltage shutdown for Installer and firefighter safety USA - GERMANY - ITALY - TRANCE JAPAN - CHINA ISRAEL - AUS1RAUA WWW.50Iaredig'..US THE Vinamount f , 1 TSM-PDO5.18 Mono Multi Solutions DIMENSIONS OF PV MODULE ctEC?R€CAL DATA,,'STC unil.nTm Peak Power Watts-Pm"x(Wp) 245 250 255 260 941 ',, Trinalv-riount Power[?utput Tolerance-PM",lr O t-+3 o i Maximum Power Voltaget-Im (( 29.9 30.3 30.5 30.6 ull", o0 sox Maximum Power Cl)Trent•IMw(A) 8;20 8.27 8.37'. 8,50 THE ""EPL"TE � Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 0 e9.r Short Circuit Current-isc(A) 8.75 8.79 8.88-- 9.00 \INSL"CLING HOLE - : 8 Module Efficiency nm(%) 15.0 15.3 15.6 15.9 STC:Irradiance 1000 W/m'.Cell Temperature 25"C,Air Mass AM1.5 according to EN 60904-3. Typical efficiency reduction of 4,5%at 200 W/m'according to EN 60904-1. CeCTR€Cn'..DATA 'NOCT MaximumPower PM"x(Wp) 182 186 190 193 CELL Maximum Power Voitoge-VM>(VI 27.6 28.0 28,I 28,3 MULTICRYSTAILiNE MODULE ce<,cnouroNCNOLE Maximum Power Current-IMVP(A) 6.59 6.65 6.74 6.84 WITH TRNAM©UNT FRAME oaNNNae A . A Open Circuit Voltage(V).Voc{VI 35.1 35,2 35.3 35.4 Short Circuit Current(A)-lsc(A) 7.07 7.10 7.17 7.27 NOCT:Irradiance at 800 W/m'.Ambient Temperature 20'C.Wind Speed 1 h-i �' �22�► PD05.18 � 812 80 Back View POWER OUTPUT RANGE MPC>IANI AL DATA 11 Solar cells Multicrystaliine 156 x 156 mm(6 inches) Fast and simple to install through strap in mounting solation Cell orientation 60 cells(6 x 10) �- Module.dimensions 1650 x 992 x 40 mm(64.95 x 3905 x 1.57 inches) AXIMUMEFFICIENCY Glass 3.2 mm(0.13 tnches),High Transmission,AR Coated Tempered Glass A A Backsheet White Goad aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove o+3� v CURVES Of P MODULE(a �v3 Cables IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm2(0.006 inches'). ....._... _.__.._. ......_.... .......... ....... ........._ 10.CO 1200 mm(47.2 inches) P }WER OUTPUT GUARANTEE _ 9.m lori - B� Fire Baling Type 2 800W/m Highly reliable zee o stringe�t quality control : bm baow�m A: leadur., 0 is g gI i( `-1i;itfa .1 re r [,�- :r _,.it `.Fit v 4 wfm - 1EMPERATURERATENGS MAXIM U MRATINGS 20ow/m Nominal Operating Cell Operational Temperature 40-+85°C 5 c Ie 2 _..._. 44°c(+2°CI Temperature(NOCT) c � 1 I _ _ Maximum System 1000v Di,ents,c l S.C h difil Jer, o°° - A Temperature Coefficient of P.. -0,41%/"C Voltage 1000V DC#UL) 0°' M. 2000 30. 4o.I- ( rE:• a r .G'�`..r r I';' -r. �a ; Temperature Coefficient of Voc -0 32%/°C Max Series Fuse Rating 15A 1 Voltage(V) C P Q toex e c $e r"Ie Temperature 0.0596/°C ir. 1Orke l Certified to withstand challenging environmental I =rid sup.,n1--e.nt a r rocvotrvr�, conditions Ir r �.a wAR€ANTv 1,,T r e ore 'tT3rn ed 10 year Product Workmanship Warranty ir)t e 1 11 rat m Il 25 year Linear Power Warranty (Please refer to product warranty for details) < t"r>d T )G--ie-s oS the bu, kb �o L �r shared ur 5.:if, CERTIFICATION rT 1 TT ,E Ji T} ". LINEAR PERFORMANCE WARRANTY /s^P PACKAGING CONFIGURATION 10 Year Product Warranty*25 YearLinear Power Warranty O �•� Modules per box:26 pieces zl ` Modules per 40'contatner:728 pieces Trims Solar Limited I m100% �M _ 3 QdCPd}ta .. I r o$value#r <o eru Hr 0 90% 58rpT TCtni85a$aY'g$tnNtFf WarraPyf CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. G�MPA lxd' o 02014 Trina Solar Limited.All rights reserved.Specifications included In this datasheet are subject to 1 80% Trin-asola chonge without notice. Smar,Lnerr}y Years 5 10 15 20 25 eeMP�� THE Tr mount MODULE sap P q$ Mono Multi Solutions DIMENSIONS OF PV MODME Ei.eC"R1Ck(.DATA c�STC unifirnry, Peak Power Wafts-Pm x(Wp) 250 255 260 265 941 - Power Output Tolerance-Prxnx(%) I o ox Maximum Power Voltage (Vi 30.3 30.5 30-6 30.8 Maximum Power Current t-1I-mra(A) $.27 B.37 8.50 8.61 THE Trinalne%l o u [---I trvAmEPurE o Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 38.3 "091 Short Circuit Current-Ise(A) 8.79 BAB 9.00 9.10 �msrnwnG HOLE s Module Efficiency qm(Y) 15.3 15.6 15.9 16.2 STC:Irradiance 1000 W/m2,Cell Temperature 25"C,Air Mass AM1.5 according to EN 60904-3MODULE . I Typical efficiency reduction of 4.57 at 200 W/m'according to EN 60904-1. o _ I to ELECTRICAL DATA NOCT ' Maximum Power PMAx(Wp) 186 190 193 197 Maximum Power Voltage-V-(VI 28.0 28,1 28.3 28.4 . E MODULE L ..,:,,. _ Maximum Power Current-IMry(A) 6.65 6.74 6.84 6.93 MULTICRYST `I. tis ­<3 GROUNDING HOLE PD05,18 n A Open circuit Voltage(V)-V- V) 35.2 355.3 3514 35.5 WITH TRIM ©UNT FRAME DRAINNOE - - Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 _ W NOCT:Irradiance at 800 W/m'.Ambient Temperature 200C,Wind Speed I m/s. 812 180 Z,50-265W'_ Back View , C;,ANICA{BATA { WER O TiPUT RANGE Solar cells Multicrystalline 156 x 156 mm(6 inches) 11 Cell orientation 60 cells(6 x 10) .... .., .�.�.�.: €�s fT si�,°°r instil trot e.�r in tr�l�nttr� sc�itrrtol� Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.5/Inches) o Weight 19.6 kg(43.12 lbs) ----- -- --- --- -- - --- ----- ---- ---- Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM FF[ICIENCY Backsheet White A-A Frame Black Anodized Aluminium Alloy Good aesthetics for residential a lications 1-Box '.. IP 65 or IP 67rated Imo! Cables Photovoltaic Technology cable 4.0 mm2(0.006 inches'), 1200 mm(47.2 inches) ._.. ... ........_._.... ......._._.. &-�, UR VES OF?V MODULE{dbO } POSITIVE POWER TOLERANCE 0.00 Connector H4Amphenal e mDOw m� Fire Type UL 1703 Type 2 for Solar City W rttgf.ie tt3 tststringent qualitycontrol i�iy � i r - s RATINGS N:&X I MI3,.4 Rs-Iia>.. < 00 Nominal Operating CellOperational Temperature 40-+g5°C I Temperature(NOCT) 44°C ± ) ca TC t Maximum System 1000y6C�IEC} r, -------- viit Ih I ) zoo -- .- - t -- Temperature Coefficient of I- -0.41%rC Vottage ',.. 1004V DC(U€) ,T 1 u € i{ `- Temperature Coefficient of Von 0.32%/'C Max Series Fuse Rating 15A ,b[ e r 1fe v, .. DDD <0 so Temperature Coefficient of Isc' 0.059/°C Certifiedt withstandeF�c�ller� tr� r��slrc;� mtfao ,o xo 3K) conditions ,bI, WARRANTY rlr i irl t 10 year Product Workmanship Warranty - CERTIFICATION z 1 1 [ a r f. 25 year Linear Power Warranty w Please refer to Y I l product warrant for details , UMD c us ba � LINEAR PE W �i a 2 .. ..., _ P3.CKA.�MG CC NFIGURATIOONes r.„�_..._ EU-28 EE _ ....... )0 Year Product Warranty-25 Year Linear Power Warranty coMrnANr Modules per box:26 pieces Tt'lno Solar c5matecl _._____ ._..... ....................................-_ . � Modules per 40'container,728 pieces - ---- -- Additionaf Va{ue fresrpp T'rZTlo e 90% afrae'sll� r- a *'Ca3PLyf7t}` CAUTION.READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. paMP�TjB ® ° * ©2015 Trina Solar Lmited.All rights reserved.Specifications Included in this datasheet are subject to Trinasolar7 80% Trin-asolar change without notice W Smarr,x(.'g,.Toe+1Yf"r Years 5 10 15 20 25 solar _ - Single Phase Inverters for North America s o I a r ! @ • r SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE760OA-US/SEI 0000A-US/SEI 140OA-US SE3000A US'SE3800A US SE5000A US iSE6000A US:SE760OA US SE10000A US SE11400A US .._._.._..... ..._..._. _... __ .. ,~_... 1222__ ..._�_; .._e.... .. OUTPUT .... ..... SolarEdge Single Phase Inverters _ _ _ __ __ __ 9980 @ 208V Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA 1000Q V240V. 5400 @ 208V 10800 @ 208V For North America Max.AC Power Output 3300 4150 6000 8350 12000 .,,,,.".,.,.,."_,_,,,, 5450 Ca 240V 10950,@240V ... VA AC Output Voltage Min Nom.-Max.0i 183208-229 Vac SE3000A-US/SE380OA-US/SE500OA-US/SE600OA-US f _ _ AC Output Voltage Min:Nom.-Max iii ✓ � � � � ✓ ✓ SE760OA-US/SE10000A-US/SE1140OA-US 211-240 264 Vac AC Frequency Min.-Nom:Max.ui 59.3-60-60.5(with HI country setting 57-60-60.5) Hz i:.. .. .. ...... ...... 24 @ 21)8V 48 @ 208V ,. ' Max.Continuous Output Current 12 5 16 25 32 475 A ^�. .. _.. .__. .... .. .,..... 11.�°,240V ._... .... 42P_240V .... GFDI Threshold .,., 1 A �,..; Utility Monitoring,Islanding Protection Country Configurable Thresholds Yes y Yes - INPUT - -- -- - -- - - - - Maximum DC Power(STC) 4050 5100 6750 8100 10250 13500 15350 W rt Transformer less,Ungrounded Yes t T - Max.Input Voltage .. .. .... 500.,.... `IBSK ...... ... .. . . Nom.DC Input Voltage 325.@ 208V/350.@ 240V Vdc 16.5 @ 208V .._ 33 @ 208V Max Input Current171 9.5 13 18 23 34.5 Adc Max.Input Short Circuit Current 1 _ 45 x Reverse-Polarity Protection.__. i - _.. .___ ... Yes Ground-Fault Isolation Detection 600ksu Sensitivity a a z 'a ` ..Maximum Inverter Efficiency 97.7 98.2 98.3 98398- - 98 98 97.5@208V ..I.. .... 97@208V ., ...... q ,. Efficiency 97.5 98 97.5 97.5 97.5 CEC Weighted _...... ._.. ..7 . .._ ..... . 98,P,240V, ....... ......... 47.5 Pa 240V -`-`- Nrgntttme Fewer"ens tmFnon _ 2.5 _ 4 W . . ADDITIONAL FEATURES -- -- -- -- -- -. _ ___ l,f x Supported Communication Interfaces RS485 RS232,Ethernet ZlgBee(optional) .... n ... Reven ue Grade Data,ANSI C12.1 .... .. ..... .... ..optional"'... ,. ..._... ..._ Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit Is installedi°I ..� NE 2T4-- - a , STANDARD COMPLIANCE_ ' Safety UL1741 UL16998 UL1998 CSA 22 2 tI Grid Connection Standards IEEE1547 Emissions FCC partly class B I __.. ...._. .__.... ._. INSTALLATION SPECIFICATIONS _ - - i - AC output conduit size AWG range minimum AWGran e / / --- -- 4' /16 6 AWG �. . .minimum/8-3 AWG - �" --- Input conduit size p of strings 3/4 minimum/1-2 strings 3 / /4 minimum/1 2 strings/16-6 AWG ,� r r* P, .. .. .. .... ...... .. ... .. ..... ... 14-6.AWG .....i.. a Dimensions with Safety Switch 30.5 x 12 5 x 10.5/ in/ ,(HxWxD) � 5 x 184 _ 775 x 315 x 260 30 5 x 125x 72 775x31 �,. Weight with Safety Switch 517./232 -54.7/247. - 88 4/40.1 _i Ib/kg Natural __. _. " � � � i.. convection Cooling Natural Convection and Internal Fans(user replaceable) _.s _ �,` fan(user ' ' NirF'fCC "#�.� .{3�1 ' , E , .. .., .":. �:�' ....................................j. ... .... ....... .,... ..._......... ..... replaceable).......... .._._...............�... .. TIN yy ,... s'`r: fik .;+-,1-� :> ....-�- .: Noise <25 <50 dBA .. ............................. ............. ....... ......... ...,............_................ ......... r ince r+ d arC fad prC�f$On° k{ �> .,. ,„ ,... �, �C s Min:Max.OperatingTemperaturei" .., -13 to+140/-25 to+60(40 to+60 version availableisl) F/"C a . . ..... .. .. .................. . ....,...,. .... . . . . . .. ... .ir,.$U�ke,C '':'£effiGierlC_{q'��'�.j � _ �,.; Range..... ..... _ .._. .. _. _.. _ X �..:. _ r..:.� .: .. ..... .... ....................................... ....... ........ ....................................................... ......... .......... t� E, i y� Protection Rating NEMA 3R Small, I It i l7 ar�d et 't I�f t {i on p{ f id �t for other reg onal settings please contact SolarEdge support �y fir, p ''- R�A higher current source may be used;[he inverter will-m t-[-p t rent[o the values stated. BulltArtmodule-level lnortltoring - is�Revenue grade nverter P/N.SE....A US000NNR2 ifor 760OW-nverter:SE7600A-US002NNR2). {, {� ♦ t'_ �°�Rapid shutdown kit P/N SE1000-RSD-Sl. J- Interm4connecticln through Ethernet orIr 1C3� is�-40 vers'onP/N:SExuxxA-U5000NNU4(for 7600W inverterSE]600A-U5002NNU4). Outdoor and indoor instaf-ation Fixed voltage inverter,DC/AC conversion Only Pre-assembled Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 sunsp USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIFl 1HENETHERLANDS-ISRAEL. www.SOlaredge.US