Loading...
38C-010 (8) 108 GROVE ST- UNITS C& D BP-2016-1011 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38C-010 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Cateporv:NEW DUPLEX BUILDING PERMIT Permit# BP-2016-1011 Project# JS-2016-001195 Est. Cost: $456100.00 Fee: $1635.30 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: STEPHEN FERRARI 98877 Lot Size(ss . ft.): 24916.32 Owner: SHOP DEVELOPMENT LLC toning: URB(100)/ Applicant: STEPHEN FERRARI AT. 108 GROVE ST - UNITS C & D Applicant Address: Phone: Insurance: 103 RYAN RD (4 13) 588-82L5-0 FLORENCEMA01062 ISSUED ON:2/18/2016 0:00:00 TO PERFORM THE FOLLOWING WORK.•CONSTRUCT 2 STORY DUPLEX W/DECK & DET 4 CAR GARAGE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sivature: FeeType: Date Paid: Amount: Building 2/18/2016 0:00:00 $1635.30 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File 4 BP-2016-1011 APPLICANT/CONTACT PERSON STEPHEN FERRARI ADDRESS/PHONE 103 RYAN RD FLORENCE01062(413)588-8975 Q PROPERTY LOCATION 108 GROVE ST-UNITS C&D MAP 38C PARCEL 010 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid ' Building Permit Filled out Fee Paid Typeof Construction: CONSTRUCT 2 STORY DUPLEX W/DECK&DET 4 CAR GARAGE New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 98877 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ON PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission _Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management oy p_ V�! Signature of uil mg ficial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. Department use City of Northampton Status of Permit; Building Department Curb Cut/Driveway Permit 1.016 212 Main Street Sewer/SepticAvailabUity Room 100 Water/ Well Availsbilitv DEPT OF BUILUNG INC-nON5 orthampton, MA 01060 Two Sets Of Structural Plans NORIYAMPTON,MA a�r 3-587-1240 Fax 413-587-1272 PIoUSite Plans Other SpeclYy APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION /to ff-,t 4- fleZ-cwic 1.1 Property Address: This section to be completed by office 108 C,D Grove Street Map Lot Unit Northampton, MA Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: SHOP Development, LLC 43 Winterberry Lane, Florence, MA 01062 Name(Print) Current Mailing Address: Signature Telephone 413-695-3314 2.2 Authorized Agent: Steve Ferrari 103 Ryan RD, Florence, MA 01062 Name(Print) Current Mailing Address: 413-588-8975 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building $385, 000 (a) Building Permit Fee 2. Electrical $19, 100 (b) Estimated Total Cost of Construction from 6 3. Plumbing $23 , 900 Building Permit Fee a 4. Mechanical (HVAC) $29, 000 5. Fire Protection 6. Total = (1 +2+3+4+5) $456 , 100 Check Number This Section For Official Use Only Building Permit Number: DateIssued: Signature: Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be tilled in by Building Department Lot Size 57 Acre .57 Acre Frontage 163 .7' 163 .7' Setbacks Front 9$ 5 11 Side L: R: L: 1516 R: 19' Rear 831 Building Height 23.51 Blda. Square Footage % 4109 sf 16% All 3 Structures Open Space Footage (Lot area minus bldg&paved 17,931sf 70% parking) #of Parking Spaces 6 Fill: volume&Location) 23.5' A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO ® DON'T KNOW ® YES CX IF YES, date issued: 12/16/2014 IF YES: Was the permit recorded at the Registry of Deeds? NO ® DON'T KNOW 0 YES (X ) IF YES: enter Book 12091 Page 72` and/or Document# B. Does the site contain a brook, body of water or wetlands? NO 0 DON'T KNOW 0 YES CI IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued: 5/05/2015 C. Do any signs exist on the property? YES 0 NO f x) IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO ID IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO 1v IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House' [x] Addition ❑ Replacement windows Alteration(s) ❑ Roofing F-1 Or Doors 1:1 1 1 Accessory Bldg. E-1 Demolition El New Signs [[3] Decks [M Siding[0] Other[a Brief Description of Proposed Construct a new Two Family building with detached garage Work: Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes —No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family X Other b. Number of rooms in each family unit: 4/5 Number of Bathrooms 1/1.5 c. Is there a garage attached? No, Detached 4 Car Garaqe 2752 sf & 1063sf 511 -311 x 441 -311 Irr. d. Proposed Square footage of new construction-Garaae Dimensions e. Number of stories? two t Method of heating? Electric- ASHP Fireplaces or Woodstoves none Number of each g. Energy Conservation Compliance.E.E. Plan attached Masscheck Energy Compliance form attached? h. Type of construction Wood Frame i. Is construction within 100 ft. of wetlands? X Yes No. Is construction within 100 yr. floodplain—Yes X No j. Depth of basement or cellar floor below finished grade 01 k. Will building conform to the Building and Zoning regulations? X Yes No . I. Septic Tank_ City Sewer X Private well__ City water Supply X SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1, Bruce Volz as Owner of the subject property hereby authorize Stephen Ferrari to act on my beh in all matters relat"to work authorized by this building permit application. 2 12 Z/( Signature of Owner Date Stephen Ferrari as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print N V Signatu J of ner/Ag� I 4 Date y 'SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable 0 Name of License Holde Stephen Ferrari CS-098877 License Number 103 Ryan Road, Florence, MA 01062 5/23/2017 Address Expiration Date 413-588-8975 SiWat UA Telephone 9.Registered Home ImIgovernent Contractor: Not Applicable x Company Name Registration Number Address Expiration Date Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152, 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. 11. - Home Owner Exempfion The current exemption for"homeowners"was extended to include one(|) mtwo(2)families and to allow such homeowner to engage an individual for hire who does not possess a license, as supervisor.CMR 780, Sixth Edition Section 108.3.$.]. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures. . Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official, responsible for all such work nerformed under the builging permit. As acting Construction Suvervisor your presence onthe job site will barequired from time tutime,during and upon completion ofthe work for which this permit imissued. Also boadvised that with reference tuChapter |52(VYorkom` Compensation) and Chapter |j3 (Liability nfEmployers to Employees for injuries not resulting inDeath)n[the Massachusetts General Laws Annotated,you may be liable fbrpmmon(m) you hire toperform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City o[ Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. |-Iomeo*/oerSiguuturo City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 108 Grove ST, Northampton, MA The debris will be transported by: Amherst Trucking The debris will be received by: Building permit number: Name of Permit Applicant Steve Ferrari Date Signature of Permit Applicant The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations I Congress Street, Suite 100 Boston, MA 02114-2017 www.mass.gov1dia Workers' Compensation Insurance Affidavit: Builders,/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/individual): Steve Ferrari, FCM Smart Build Address: 103 Ryan Road City/State/Zip:Florence, MA 01062 Phone #:413-588-8975 Are you an employer? Check the appropriate box: Type of project(required): 1.[1 1 am a employer with 4. [] I am a general contractor and 1 6. FE11 New construction employees (full and/or part-tit-ne).* have hired the sub-contractors 2.0 I am a sole proprietor or partner- listed on the attached sheet. 7. F-1 Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its I 0.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their I I.FPlumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.M Other comp. insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. lContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for ntv employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins. Lie. Expiration Date: Job Site Address:— City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. Idohereby ce rfJ under the pains andpenalties of Perjury that the information provided above is true and correct. �i�ure: k Date: January 21, 2016 Phone#: 413-588-897., Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6. Other L11iCENTER FOR U]MlEcoTechnology' we make green make sense- ENERGY EFFICIENCY PLAN Project Address: 108 Grove St., Northampton MA Conditioned Floor Area 1380 ft2, 1291 ft2 Volume 15180 W, 13612 ft3 Building Type Two units flats Bedrooms 2 1. Assumptions for Preliminary Home Energy Rating CET has completed a Preliminary Home Energy Rating with the following assumptions: a) The construction plans you have provided are accurate, including window dimensions and locations. b) Energy features not listed below in part c will meet the prescriptive requirements of the IECC 2012. c) The home will be built to incorporate the following energy features: Building Envelope Specifications Used in Analysis 4"XPS (R-20) insulation at edge Slab Floor 4"XPS R-20 insulation underneath Overhanging Floors 14"dense packed cellulose (R-49) 14" joists, 16" on center Exterior Walls 2x4 double stud wall with 3" space Filled with dense pack cellulose(R-R-35) Band Joists 3"closed cellspray foam R-1$ Windows U-value=0.27 SHGC =0.24 Glass Doors U-value= 0.27 SHGC= 0.24 Exterior Doors R-5/U-0.20 4" XPS (R-20)on top Roofs/Ceilings 14"dense packed cellulose in cavities(R-49) 14" joists, 16 inches on center Blower Door Test* 1.5 ACH50 or better* Thermal Enclosure Checklist Meet all Checklist Requirements as verified by a HERS rater at pre- drywall and final inspection *The 2009 IECC requires a blower door test result of 7 ACH50 or lower and the IECC 2012 requires 3 ACH50 or lower. Mechanical Systems Specifications Used in Analysis Ductless mini-split heat pumps Heating& Cooling Equipment 12.5 HSPF, 27 SEER Properly sized and documented on HVAC Contractor Checklist Duct System Located in conditioned space Water Heating Equipment 1.45 EF heat pump water heater Heat Recovery Ventilator Whole House Ventilation 80% Sensible Recovery Efficiency 40 CFM, 40 watts Liahtina 8r Appliances Specifications Used in Analysis ENERGY EFFICIENCY PLAN Lighting 90% CFL, LED, or pin-based fluorescent Refrigerator ENERGY STAR rated Dishwasher ENERGY STAR rated Clothes Washer ENERGY STAR rated 2. Preliminary Home Energy Rating Results Based on the assumptions described above, we have calculated the following Preliminary Home Energy Rating results. Preliminary HERS Index: Lower Unit: 42, Upper Unit: 45 Preliminary Improvement Over 2014 Mass. Reference Home v2: Lower Unit: 66.4%, Upper Unit: 52.9%-Tier III* Note that Confirmed Home Energy Rating results may vary from the Preliminary Home Energy Rating results due to changes in building plans, energy features installed in the home, RESNET standards, software changes, and other factors. 3. Services Requested CET will provide a Confirmed Home Energy Rating for the purpose(s) indicated below. CET will charge fees for these activities based on your Home Energy Rating Services Agreement. • Stretch Energy Code compliance • Incentives for the Mass Save Residential New Construction program—Tier III* *= Mass Save Residential New Construction requirements and incentive amounts can change at any time without notice at the discretion of program sponsors. We anticipate, but do not guarantee, that current program requirements and incentive amounts will apply to this project as long as it is completed and inspected by November 30, 2017. As part of these services, CET will verify that your home meets all the requirements of these programs. I have reviewed and understand this Energy Efficiency Plan. I have reviewed the assumptions in part 1 and confirm that the assumptions are correct. Signature: Date: Printed Name: Company: Preliminary Rater:Mark Newey Date: 12/29/2015 Job#:P15548 Page 2 of 2-Please send signed form to the Center for EcoTechnology Tel(413)586-7350 ext.242-Fax(413)586-7351 -greenhome(&cetonline.org 0 Permit No. D08-16 CITY OF NORTHAMPTON, MA DRIVEWAY PERMIT Date: 11/4/15 Check#: FEE: $250.00 Proposed driveway must be staked and address andlor lot number posted Public Shade Trees are protected by MGL Chapter 87. Do not cut, trim or remove any trees on City property. The undersigned respectfully petitions your honorable body for: A NEW CURBCUT Permission to install a drivewU at: 108 GROVE STREET, UNIT'S A,B,C,D Fifteen(15) foot maximum width from street line to property line. Gutter drainage not to be disturbed. All drainage shall be directed off the driveway surface to adjacent land and not on the existing roadway. The first one hundred(100)feet of the driveway surface shall be paved as soon as possible if the grade of the proposed driveway exceeds 3%at any point in the first one hundred(100) feet. Homeowners will be held responsible for any costs to the City of Northampton in the event of a washout of this driveway.City is not responsible for culverts installed under driveways in City layout. Code of Ordinances §350-8.8 providing standards for private,individual driveways as most recently amended,must be followed. By: Steve Ferrari/FCM SMART BUILD Telephone: 413-588-897-5 i ature: Proposed Location Inspection r Gravel Base Base Grade Inspected By: Final Approval: Edward S. Huntley, P.E. Director of Public Works Cc: Building Inspector (SUBJECT TO ATTACHED CONDITIONS I &2) Permit No. D08-16 Conditions: Driveway Permit In lieu of plan approved by the City Engineer I agree to the following added conditions: 1. 1 will contact the Department of Public Works and have an inspector check and approve the graded gravel base prior to paving to insure compliance with slope and location; 2. 1 further agree that if in the inspections, any of the permit conditions are not met that I will at no expense to the City remove and replace the driveway as directed by the City Engineer. Petitioner Signature Name: Steve Ferrari Address: —103 Ryan Road, Florence,MA 01062 413-588-8975 Note: The Public Works Department recommends that you provide a plan showing the proposed driveway with grades and location in the future to avoid possible expense which you will incur by not getting approval of actual plans in advance. For Commercial and Industrial applicants, a plan showing the proposed driveway with grades, location and Planning Board permits are required. Cc: Building Inspector PENDING APPROVAL CITY OF NORTHAMPTON,MASSACHUSETTS 108 a,b,c,d GROVE STREET DEPARTMENT OF PUBLIC WORKS 2016-321 125 Locust Street Trench Permit Number { Northampton,MA 01460 413587-1570 Date Approved: t 1110hTiftr- Fax 413-587-1576 Expiration Date: 121141 (for City Use Only) I EXCAVATTON/TRENCH PERMIT Pursuant.to G.L.c.82A and 520 CMR 14.00 et seq.(as amended) 1 This permit must be fully completed prior to consideration.Submit completed form with permit fee to Northampton Department of Public Works, 125 Locust Street,Northampton,MA 01060. This permit is issued under the provisions of M.G.L.c.82A,520 CMR 14.00 and applicable sections of the ` Revised Ordinances of the City of Northampton,including,but not limited to,Section 285-21. i 3 Fee:$250 Check#: 1005 Date Issued: 11/9/15 Name of Applicant Primary Phone# DAVE LOVEN 413-695-7304 Street Address Emergency Phone# 230 RESERVOIR.ROAD 413-695-7305 City/Town State Zip Email. WESTHAMPTON MA 01027 Name of Excavator Primary Phone# SAME Street Address Emergency Phone# City/Town State Zip Email Name of Property Owner(s) Primary Phone# BRUCE VOLZ 413-695-7304 Street Address Emergency Phone# 108 GROVE STREET, A,B,C,D 203-3050 City/Town State Zip Email NORTHAMPTON MA 01060 Insurance Certificate# Policy Expiration Date ON FILE Name&Contact Information of Insurer ON FILE Dig Safe# 2015-450-5539 Pg.114,Excevagon/Tweh Peng i • - I • - 1 Project Description/Location of Work.Provide the following F] Description of purpose and exact location of proposed work including description of what is to ' be laid or repaired in the proposed trench(eg water pipe,sewer pipe,drain pipe,gas line, power line,communication lines,etc Sketch or drawing showing all proposed work F Anticipated Start of Work Date. ' t4ewC14�ZCu/q4c-t,,-4- sOW,� 1 ]-gI S ecv�r r-Y I+ U14i� a bCAM'L g i i YES NO Check here if Emergency. V Describe. Work in Public R!i -of-Wa Work on Private Pro Work within State Layout If es-attach State Permit Work within 100 fh of a wetland or 200 ft of a stream or river. es,attach permit Work within Floodplain. attach Permit Public Water/Sewer/Drain Entry Permit Attach Perini if available Drivewa Permit Attach Permit,if available i . i i By signing this form,the.applicant,owner and excavator all acknowledge and certify that they are familiar with,or,before commencement of the work,will become familiar with,all laws and regulations applicable to work proposed,including OSHA regulations,M.G.L.c. 82a,520 CMR.14.00 et seq.,and any applicable municipal ordinances,by-laws and regulations,and they covenant and agree that all work done under the permit issued for such work will comply therewith in all respects and with the conditions set forth below. The undersigned owner authorizes the applicant to apply for the permit and authorizes persons duly appointed by the municipality to enter upon the property to monitor and inspect the work for conformity with the conditions attached hereto and the laws and regulations governing such work for the duration of the construction. The undersigned applicant,owner and excavator agree jointly and severally to reimburse the municipality for any costs and expenses incurred by the municipality in connection with this permit and the work conducted thereunder,including but not limited to enforcing the requirements of state law•and conditions of this permit,inspections made to assure compliance therewith,and measures taken by the municipality to protect the public where the applicant,owner or excavator has failed to comply therewith,including police details and other remedial measures deemed necessary by the municipality. The undersigned applicant,owner and excavator agree jointly and severally to defend, indemnify,and hold harmless the municipality and all of its agents and employees from any and all liability,causes or action,costs and expenses resulting from or arising ouf of any injury,death,loss or damage to any person or property during the work conducted under this permit. By signing this form,the applicant,owner and excavator acknowledge that they have read and understand all the information set forth in and referenced within this application package and that they agree to comply in all respects with the requirements therein_ Applicant Date Excavator Signature(if different) Date IlAkI4 Owner Signature(if different) Date Pg.WI O To be completed when approved permit is picked up. By signing below,the applicant acknowledges and agrees to all the conditions of approval stated below and validates this permit. Applic Da f For City Use—Do not wtite,in this section Department Approvals/Comment Other Referenced Permits Water 6 Sewer Streets (/ Condition of road: Road last paved: Conditions of Approval F] Control Density Fill Required F1 Refer to Engineering for plans F1Must install clean-out(See Attached) F] Subject to 5-yr.pavement moratorium F] Other requirements(See Attached) Water/Sewer/Drain Entry Permit Fee F] $250 Permit Application Fee received(Check payable to the City of Northampton) F] Fee Waived. Reason: Permit Approval Director of Public Works Date Pg.414 Permit No. W30-16 CITY OF NORTHAMPTON,MA RESIDENTIAL OR COMMERCIAL BUILDING WATER ENTRY APPLICATION A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. To the City of NORTHAMPTON, MASSACHUSETTS: The undersigned,being the Owner's Agent of the property (Owner,Owner's Agent) located at 108 Grove Street, A,B, C,D, ,does hereby request a permit to install and (Number) (Street) connect a I" Water Service to the Residence at said location. (Size) (Residence,Commercial Bldg.,etc.) 1. "Owner" shall mean the person holding title to the property served or to be served by the water service. 2. The person or firm who will perform the proposed work is Dave Loven Excavating of 230 Reservoir Road, Westhampton,MA (Name) (Address) 3. Plans/sketch and specifications for the proposed water service shall be attached to permit. In Consideration of the granting of this permit the undersigned agrees: I. The Water Department shall make all taps to the water main. 2. WATER ENTRY PERMIT FEE is$200.00. 3. Additional work performed by City forces from the water main to street line shall be paid at the prevailing labor rates and cost of material Water Meters 5/8" $130.00 Water Meters ala" $140.00 Radio Read$135.00 Water Meters 1" $180.00 ***** Water Meters 1.5"and above shall be purchased by the owners using city specs. 4. A fee of$135 for the Radio Read Fee with the purchase of a new meter. 5. The Water Superintendent shall be notified for water line inspection prior to backfill of trench. Permit No. W30-16 CITY OF NORTHAMPTON,MA RESIDENTIAL OR COMMERCIAL BUILDING WATER ENTRY APPLICATION DATE: 11/9/15 (Applicant) Name of Applicant: Steve Ferrari Address of Applicant: 103 Ryan Rd, Florence,MA 01062 Telephone 4: 413-588-8975 $ 200.00 Entry fee paid Check No. 1006 $ 520.00 Meter fee paid (x4) Check No. 1006 $ 540.00 Radio Read Fee(x 4) Check No. 1006 Application approved and permit issued: DATE: 0110 SIGNED: i fector ou is or ) Fee Schedule: Water Entry Pen-nit Fee: $200.00 5/8"Meter Fee $130.00 3/"Meter Fee $140.00 1"Meter Fee $180.00 Radio Read Fee: $135.00 \\win2\admin\Permits\Water Application\Water Permit 2016\W30-16 108 Grove Street.doc Permit No. W30-16 WATER CONNECTION INSPECTION REPORT Northampton Water Department 237 Prospect Street Northampton,MA 01060 . (413) 587-1570 Date: 11/9/15 Type of Service: New FX-1 Renewal E-1 RepairEl Pipe: Size 10" Material Cl Age 1939 Water Entry Fee: Paid Yes F-X—] No [,_:= N/A = Meter Size 5/8"x4 Fee Paid Yes No N/A Radio Read Fee: Paid Yes FXI Check# Cash Location of Installation: 108 Grove Street A,B,C,D, (Street and Number) Permit Issued To: Steve Ferrari Contractor/Developer Installing Service Connection: Dave Loven Excavating Telephone No.: 413-588-8975 The service connection at this location was inspected by the undersigned on (Date) at and approved by (Time) water Supermtendent I have instructed of that the installation can be backfilled. Measurements for all installation shall be documented by the Water Department. The information shall be on file at the Public Works Department office. Copy to Supervisor: Date: Copy to Utility Billing: Date: Copy to Office Manager: Date: Permit No.S23-16 CITY OF NORTHAMPTON,MA RESIDENTIAL OR COMMERCIAL BUILDING SEWER APPLICATION A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. To the City of NORTHAMPTON,MASSACHUSETTS: Owner's Agent property The undersigned,being the f the pror (Owner,Owner's Agent)___ Ilocated at - 10-8 Grove St, Unit A,B,C,D--'--- —s hereby ecby_request a permit to install and (Number) (Street) onnect a building sewer to serve the Residence at said location. (Residence,Commercial Bldg.,etc.) 1. The applicant and/or owner shall furnish upon request of the Superintendent the estimated quantity and characteristics of waste to be discharged to the public sewer. 2. "Owner" shall mean the person holding title to the property served or to be served by the building sewer. 3. The person or firm who will perform the proposed work is Loven Excavating/Dave of 230 Reservoir Rd, Westhampton, MA (Name) (Address) 4. Plans and specifications for the proposed building sewer are attached hereunto as Exhibit "All. In Consideration of the granting of this permit,the undersigned agrees: 1. To accept and abide by all provisions of the Code of Ordinances,City of Northampton, Massachusetts, Sections 22-41 through 22-52,and all other pertinent ordinances or regulations that may be adopted in the future. 2. To maintain the building sewer at no expense to the City. 3. To notify the Superintendent when the building sewer is ready for inspection and connection to the public sewer,but before any portion of the work is covered. 4. The City shall not be held liable for any open plumbing fixtures below street level. 5. The applicant and/or owner hereby agrees to pay to the City any sewer use assessments or charges as may be established under city ordinance. 6. City requires 6" cleanout installed at City Property Line. D ATE:' SIGNED: (Applicant) Steve Ferrari 103 Ryan Rd,Florence, MA (Address of Applicant) 413-588-8975 (Telephone No. of Applicant) 200.00 inspection fe "hec ,e ppaid: 1006 Application approved and permit issued: A 11119111" SIGNED: lector of Public Works) Code of Ordinances Section 22-41 through 22-52 available upon request. e-in to sanitary— -ffi-a—jn T — — - --- -� --,- I Tie-in to sanitary service at street line --- --- "-$.5-0--0.0--0 \\win2\admin\Permits\S ewer Entry\Permits 2016 Sewer\523-16 108 Grove St A,B,C,D.doc SEWER CONNECTION INSPECTION REPORT Northampton Sewer Department 125 Locust St. Northampton,MA 01060 (415) 587-1570 Engineering has taken ties to 11/6/15 service S nature Renewal T Existing �Tyj�e of Service: Few -7 _N— -------T Repair� T–L��Rc Sewer Entry Fee: Paid Yes LX7] No = N/A Check L��6 Cash Pipe: Material Clay Age T -- F cation �o of Installation 108 Grove St,A,B,C,D 2 Bldgs 4 units (Street and Number) (Permit Issued To: Steve Ferrari, 103 Ryan Rd,Florence,MA 413-588-8975 L ontractor/Developer Installin Loven ExcavatingtDave Loven Service Connection: 230 Reservoir Rd,Westhampton,MA 01027 �elephone No.: 413-695-7304/413-203-3050 (she7w�ice connection at this location was inspected by the undersigned on i at and approved by: jime�— Sewer Supervisor have instructedthat the T nstallation can be backfilled. *City r quires ' cleanout installe at city roperty ropeme. - Measurements for all installation shall be listed on the back of this form. The information shall be attached to the permit on file at the Public Works Department office. Copy to Supervisor: I — Date: Copy to Utility Billing: 2 Date: Copy to Office Manager: 1 Date- Grove Street Condos Floor Areas Cost 1523 i.50 per square foot for 1st floor — $761.50 1229 .50 2nd floor $614.50 1063 garage -- $213.00 246.5c $49.30 @.20 psf --- $49.30 for house & Gara eh -- — $1,638.30, for house Alone $1,425.30{' City of Northampton Massachusetts ; � . , I DEPARTMENT OF BUILDING INSPECTIONS = 212 Main Street •'Municipal Building ., ti ^• Northampton, MA 01060 �sy . 1 ` INSPECTOR Stephen Ferrari February 17, 2016 103 Ryan Road Florence, MA 01062 Subject Location: 108 Grove Street, Units A&B and C&D Map Block: 38C-010 Mr. Ferrari, Your building permit applications with plans dated 2-2-2016 have been approved as drawn and per this memo. All work must meet all applicable codes whether noted or not included within this memo. Please follow up on the following items: These items will need to be accomplished as the project moves forward; 1. Final ratings, duct blast results, and a signed Thermal Bypass Checklist. 2. Smoke, Heat and CO detectors throughout the structure to current building codes. 3. An emergency escape window is required within every bedroom. 4. An air barrier is required between the tub or showers and the wall cavity. 5. Dryer exhaust hidden within the framing require signage per M504.6.5 6. Tempered windows are required at the top and bottom of the stairs within 60". 7. Detail 5/A102 show 9% I-joist structural has 117/8. 8. Details and section show roof insulation of less than the cavity depth, the roof cavities must be filled with dense pack insulation per the energy plan. Note:The 2012 IECC with MA amendments is the non-stretch energy code and the 9th Edition Building Code and new Stretch Code are expected to begin in July of 2016. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. Read only international codes are available on line at"http://pubiicecodes.cyberregs.com/icod/one must also consider the MA amendments to these codes which can be found at www.mass-Rov/dps/­­bbrs . The current relevant building codes are: 2009 IBC, 2009 IEBC, 2009 IMC, 2009 IRC, 2009 or 2012 IECC,AA115, MA amendments. 1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3.except those in group I soils(table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. or if high water table or severe soils waterproofing 780 CMR R406.2. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement. 780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be%" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing. 780 CMR R406.1 see exceptions. 8. Emergency escape is required out of every basement whether habitable or not, each bedroom and walk- in attics. 780 CMR R310.1 9. Crawl spaces can be treated in three different ways,vented (poor idea), exhausted (similar to exhaust only systems), or treating the space with supply and return. See 780 CMR R408 10. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4"slope 8-16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. 11. Steel straps over the ridge or 1x4 minimum collar ties are required 4'OC in the upper 1/3rd 780 CMR R802.3.1 12. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 13. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 14. Wood walls shall be capped with double plates to provide overlapping at corners and intersecting walls with bearing partitions,joints staggered 2' minimum. 780 CMR R602.3.2 a. Exception:A single plate may be used or plates may be excluded over lintels provided the plates/lintels are adequately connected by a 3"x 6" plate .036 galvanized steel nailed to each segment with 6-8d nails 15. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I-joist and or Floor Truss c. Roof truss 16. All I-Joist need to be protected from fire with%drywall or 5/8 wood structural panel. (R501.3) 17. A braced wall plan identifying appropriate braced wall areas where required (R301.1) and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. c. When using PFH (R602.10.3.3)or PFG (R602.10.3.4)the nailing requirement is 4" and 3" respectively using 8d common nails or galvanized box nails. PNEUMATIC nails must be full headed with the temper and shank sizing meeting the strict code requirement. 18. When nailing sheathing make sure your pneumatic nailers' pressure is properly set. Nails set too deep perforate the sheathing weakening it and contribute to building damage in high wind events. 19. Ceiling heights minimum 7'for habitable spaces, 6'8"for bathrooms includes tub/shower area if a shower head is used, 6'8"for basements, 6'4" at beams/ducts. 780 CMR R305.1. MA amended 20. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs,spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 21. Windows over 72"above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 22. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor, DH 3.3 sgft min window size, Casement 20"x41" exception 5 sqft at 15Y floor. Minimum clear opening 20"x24"or 24"x20". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32"and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36", maximum step 7Y4"from the top of the threshold and only in-swinging doors. 780 CMR R311.3 23. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30"or less 780 CMR R311.7.4.3 Exception,4 3/8" on balustrade, 6" in the triangle. Graspable rail 1%" minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. Rails must be continuous and returned to the wall if not to newel post. 780 CMR R311.7. 24. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30"above floor or grade within 36",4" sphere rule. 780 CMR R312.1. 25. Floor joist systems that are not equal to 1%" nominal dimension must be covered with %Z" drywall or 5/8"wood structural panel or equivalent with some exceptions. 780 CMR R501.3 26. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, or holes in joist are a maximum 1/3 the depth not closer than 2"from the top or bottom or to any other hole. Notches are different. 27. Drilling or notching of more than 50%of the wallplate width of an exterior wall or load bearing partition requires a 16 GA 1 %"strap across the area and 6" beyond each side with 8- 10nd nails. 780 CMR R602.6.1 28. Where dryer ducts penetrate the wall they must be sealed with fire caulk. 780 CMR M504.2 29. Dryer ducts must terminate outside of the building, have a backdraft damper, cannot include a screen, and require 3' clearance from windows. 780 CMR M504.4 30. Dryer duct transition is limited to 8'of aluminum flex, must be exposed, and the proper UL listing. 780 CMR M504.6.3 31. Dryer duct maximum equivalent length is 35' less 5' per 901 elbow or per manufacturer's specs. 780 CMR M502.6.4, no screwed connections use foil tape appropriate for the use. 32. Dryer ducts when concealed must have a permanent label or tag within 6'of the duct connection 780 CMR M502.6.5 33. Makeup air is required for dryers exhausting more than 200 CFM. 780 CMR M504.5 34. Makeup air is required for any exhaust hood over 400 CFM. 780 CMR M505.2 35. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5'from the duct outlet for all fireplaces and airtight doors. 2009 IECC 402.4.3 36. Fire and draft stopping shall be completed before rough inspection.Typical locations,top (ceiling) and bottom (floor) plates, soffits, and every 10'within enclosed cavities. 780 CMR R302. 37. Ignition barriers are required over all thermal plastics and must be in place before final. 780 CMR R316. 38. Dwelling/Garage fire separation.An attached garage (within 3'of main structure) is required to have%" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have%" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 39. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist. Duct blast testing when practicable. f. All band joist insulation must be enclosed within an air tight cavity, which you must create. 40. Vapor retarders.Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier.An air barrier is intended to stop air flow(convection) a vapor retarder or barrier is intended to stop molecular moisture transfer(diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99%of the moisture in a structure.This is evident every time one exposes fiberglass insulation and finds black insulation, which has filtered dirt out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 41. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 42. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note:ThruLoks are engineered for post attachment supporting a railing. Lateral attachment is required for each deck per section 502.2.2.3. 43. Smoke and CO detectors as required. 780 CMR R314 and R315. a. Smokes in each bedroom, within 10'of a bedroom door, and at the bottom of a stair leading to a finished floor above. b. CO within 10' of bedroom doors, at each level, for every 1500 sqft, (plumbing code in the mechanical room) Except if there are no fossil burning fuels or attached garage. c. Heat detector in attached garage, and other large unfinished unconditioned spaces. 44. Closets beneath stair which have doors must be drywalled with %Z". 780 CMR R302.7 45. If there is mechanical equipment or a combustible roof, 30 sqft of space, and 30" measured from top of ceiling joist to bottom of rafters an attic access of minimum RO of 22"x 30" is required to be located in an accessible place. It must be insulated equal to surrounding,gasketed, and secured in place. 46. Clearances above gas stoves and cook tops burners is 24" to non-combustible or 30"to combustibles. Relevant items must be submitted to the building department for approvals before inspections and or Certificates of Occupancy can be issued. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm,excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmillerC-northamptonma gov Thank you for your cooperation on the at rs. Chuck eller City of Northampton Assistant Commissioner and Zoning Enforcement