Loading...
18C-063 (2) 165 PROSPECT AVE BP-2016-0970 GIS #: COMMONWEALTH OF MASSACHUSETTS Ma :Block: 18C-063 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-0970 Project# JS-2016-001645 Est. Cost: $23000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq. ft.): 9452.52 Owner: MILIANN KANG&CUONG N LE zoning: URB(100) Applicant: SOLARCITY CORP AT. 165 PROSPECT AVE Applicant Address: Phone: Insurance: 604 SILVER ST 978 215-2369 Workers-Compensation AGAWAMMA01001 ISSUED ON.•2/2/2016 0:00:00 r TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED/i'lKW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature• FeeType: Date Paid: Amount: Building 2/2/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2016-0970 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (978)215-2369 Q PROPERTY LOCATION 165 PROSPECT AVE MAP 18C PARCEL 063 001 ZONE URB(I00)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ZONING FORM FILLED OUT ENCLOSED REQUIRED DATE Fee Paid Building Permit Filled out Fee Paid &— Typeof Construction: INSTALL ROOF MOUNTED KW SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accesso Structure Buildin,,Plans Included: Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: —41A-11proved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR _Special Permit With Site Plan Major Project: Site Plan AND/OR _Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: §_ Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management ay /6000, SiZ of ui ing I 1 Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. Dp e� C t of Northampton ` Y P s 0 Z � CC B ilding Department 'max dx� 12 Main Street tic A 11t) Room 100 ort mpton, MA 01060 Awa tr�a # ri pE�,o;-autLn "�3- 7-1240 Fax 413-587-1272 '' NJ�THAA PT N h ` itr APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed;by office 165 Prospect Ave Map Lot unit Zone Overlay District Elm St.District CS District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: C N Le 165 Prospect Ave,Northampton, MA 01060 Name(Print) Current Mailing Address: 413-585-1025 Telephone Signature 2.2 Authorized A-gent: SolarCity CorpNictoria Juncy 604 Silver St Agawam MA 01001 Name(,PrW Current Mailing Address: 978-215-2367 Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 7,000 (a)Building Permit Fee 2. Electrical (b)Estimated Total Cost of 16,000 Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) 23,000 Check Number 17 7V7JV This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be tilled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all an icable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs j ] Decks [ ] Siding[ ] Other❑✓ Brief Description of Proposed �—�i Work: Install solar electric panels to roof of existing home to be interconnected with home's electricals system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a.if New house and or addition to existing housing, 00MR1e1e the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 02/01/2016 Signature of Owner Date SOLARCITY CORP/VICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORP/VICTORIA JUNCK Print Name - 02/01/2016 Sie o er/Agent l Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Address Expiration Date 978-875-1698 Signature Telephone 9 Rettlstemd Home Improvement Contractor' Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM 01001 03/08/2017 Addres Expiration Date Telephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. Home Owner Exempti©n The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780 Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature Tito Commonwealth of Massachusetts Department of IndustrialAccidents l Office Of investigations 1 I Congress Street,Suite 100 Boston,AIA 02114-2017 t,,p i,..�.5,�� mvit:mass govIdi r Workers'Compensation Insurance Affidavit: Builders/C(it/tractors/E lectrician,91plumbers Applicant Inform tion Please Print Legibly Natmc(BusincWotganizationffndividual): SOLARCIN CORP Address:3055 CLEARVIEW WAY City/State/Zip:SAN MATED, CA 94402 Plane#:88e-765-2489 Are you an employer?Check the appropriate box: 50t#0 4. I am�general contractor and I Type of project(required): 1.® 1 am a employer with Q s 6. [:]New construction employees(frill and/or part-time),* have hired the sub-contractors 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. [] Remodeling ship and have no employees These sub-contractors have g. []Demolition working for me in any capacity, employees and have workers' [No workers' comp.insurance comp. insurance. # 9. E] Building addition required.] S. E] We are a corporation and its 10.[] Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 1 IQ Plumbing repairs or additions myself [No workers' comp, right of exemption per MG., 124:1 Roof repairs insurance required.]t c. 152,§1(4),and we have no SOLAR1 PV employees. [No workers' 13A Other comp. insurance required.] *Any applicant that cltccls box#1 must also till ont the soclion below showinglheir workers'compensation policy infotination. t Homeowners who submit this affidavit indicating they are doing ail work and then hirc outside conimf fors must submit a new affidavil indicating such. tContractors that check this box must attached an additional shcet showing the name or the sub-contractors and state whether or not those entities have ernployces. Irthe sub-cantraclors have aanployccs,fhcy must provide their workers'cornp,policy nurubcr. I am an employer that is providing workers'compensation insurance far my emiployeay. Below is lite pol kv andjab site Information. Insurance Company Name: Zurich American Insurance Company Policy 11 or Self-ins. Lic. M. WC0182014-00 _ Expiration fate: 09/01/2016 lob Site Address: I(r 6 �V Q Q-ec-, IJP Cityfstate/t:ip: R A c '"0 Attach a ropy of the workers'compensation policy declaration page(showing the policy aumber and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to lite imposition ofcriminal penalties ofa fine up to$1,500.40 and/or one-year imprisonment,as well as civil penalties in the forth of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the IIIA for insurance coverage verification. I do hereby cerllfy unrlcr tke+pains and panalties of perJrrrt�deal Nie hrJornin ivn provided above Is true and correct. .S'tg 8tul'i;.: �" •�' t��,...... ..� 11�i1r. Phone t€: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Perinit/Lieensc# Issuing Authority(circle one): i.Itourd of Health 2.Building Department 3.City/Towin Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Al ter- DATE dronJYYYY) CERTIFICATE ICATE LIABILITY INSURANCE W1712016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER, THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES ` BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZER REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,Subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES PH- 'FAz" 345 CALIFORNIA STREET,SUITE 1300 "A0.E10L . ..... fA7C Not.. . .... ... . ... CALIFORNIA LICENSE NO,0437153 E-MAIL SAN FRANCISCO,CA 94104 —.............._. _... .... .......... ....... Aitn:ShannonSco#t415743.8334 tNSURER{5)AFF9Rq GLLgq%TRAGE, _ ffasc_r 998301-S?ND-GAWUE-15-16 INSURER A:brlch Ameocan insurance Company 15535 8olarcity Csxpotairon _SURED I .INSURER e I NIA +NIA _ —-—- 3055 Clearview Way INSURERC:NIA NIA San Mateo,CA$4402 - _ .INSURER p:American lunch Insurance Company 40142 tNSUREk E INSURER F COVERAGES CERTIFICATE NUMBER: SEA-00271383608 REVISION NUMBER-.4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING,ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. T TYPE OF INSURANCE AADL SUiIR .. . .. ...POLICY NUMBER ...-.—.�.POL7CY �POMC Y LICF�,—. .—...—......._....LM11TS A X .'COMMFERCIAL GENERAL LIABILITY 1GL00182016-00 0910112015 !09I01I2018 t....-, ..-,_ EACH OCCURRENCE 5 3,000,000 �' Oitt.fAGE Tf3 REtVYE6.... .. .... CLAIMS-MADE 1,x... OCCUR I ; ` ,P1�iLMtsF,s-{Ea eccurrencel...... .. 3,000.000 X SIR:$250,000 } I MED ExP(Any one person) 1 PERSONAL&ADV INJURY 5 G€N'L AGGREGATE LIMIT APPLIES PERM GENERAL AGGREGATE $ A 6,000,000 ARO, l X POLICY�.... JECT 1......E LOG PRODUCTS-COMP(OPAGG OTHER I°� A AUTOMOBILE LIABILITY 'BAP0182017.00 0911112015 09101/2016 COMBINED SING4E LIMIT s 5,000,000 X. ANY AUTO BODILY INJURY{Per perstm) S ALL OWNED .. SCHEDULED ..... _......_....._.._.. X s X BODILY INJURY(Per accidem) 5 AUTOS ..... AVTOS XX NON-OWNED PROPERTYD.AMAGE $ .. tnREDAVTOS .... AUTOS i 1PVt e!?iL.. . ...-. _ .... ....._..._ COMPICOLL DEO: s $5 coo , I UMBRELLA LIRE• I OCCUR 4 EACH OCCURRENCE S .. .. EXCESS LIAB..... CLAIMS•MADEj AGGREGATE6 OED_I ..1 RETENTION. ... ..........1 ... . _.. -. .. .... .. ... . .... .. .... t 1$ D wORKERS COMPENSATION WC0182014-I}0(AOS) 091!112015 0910112016 X (PER OT'_ AND EMPLOYERS!LtA$ILITY YIN I �....LSTATUTF _ R.... t .. _.-.. .....-. A ANY PROPRIE ORIPARTN5WEXECUTIVE WC0182015.00(MA) 09;0112015 0910112016 E.1 EACH ACCIDE14T $ � 1,0(}0000 OFFICERRMEMBER EXC4WED9 �N f A - - _..... IMandatory In NH) �WC DEDUCTIBLE:$500,D00 IE.L.DISEASE-EA,EMPLOVE s _ 1,000,000 If yes,desarthe Under _... .._._ .-.... I DESCRIPTION OF OPERATIONS befuN ! E.4.OISEASE-POLICY LIMIT $ 1,000,000 DESCRWTION OF OPERATIONS t LOCATIONS 1 VEHICLES{ACORD 161,Additional Remarks Schedule,may he attached fr more space Is requlredl Evielance of insuranca'• CERTIFICATE HOLDER CANCELLATION SoiarCily Corparalion SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Cleamm Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services I Charles Marmolejo @ 1988-2414 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:EE60FCEI-6CB9-4D67-8A99-E674DDE30994 SolarCity I PPA Customer Name and Address Installation Location Date C N Le 165 Prospect Ave 1/14/2016 165 Prospect Ave Northampton,MA 01060 Northampton,MA 01060 Here are the key terms of your Power Purchase Agreement $0 13970ce 2 01k ors y System installation cost Electricity'a h Agreement Tgjm Initial fiero(F Initial her, EM The SolarCity Promise DS •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. .......... initial her,H •We warrant all of our roofing work. IDS •We restore your roof at the end of the Agreement. •We warrant, insure, maintain and repair the System. ........................... ........................... .............. ......... . ...... Initial here L(4 •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 1/14/2016. Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: At certain times,as specified in $0 •• SolarCity will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 *You can upgrade to a new System with These options apply during the 20 Est.amount due at building inspection the latest solar technology under a new year term of our Agreement and $0 contract. not beyond that term. -You may purchase the System from Est.first year production SolarCity for its fair market value as 7,000 kWh specified in the Agreement. -You may renew this Agreement for up to ten (10)years in two(2)five(5)year increments. 3055 Clearview Way, San Mateo, CA 94402 1 888.765.2489 1 solarcity.com 1487556 Power Purchase Agreement,version 9.1.0,November 11,2015 SAPC/SEFA Compliant Contractors License VIA HIC 168572/FL-1136MR Document generated on 1/14/2016 Copyright 2008-2015 SolarCity Corporation,All Rights Reserved DocuSign Envelope ID:EE60FCE1-6CB9-4D67-8A99-E674DDE30994 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in their entirety and I acknowledge that I have received a YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR complete copy of this Power Purchase Agreement. TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:C N Le EXPLANATION OF THIS RIGHT. Docus(ignned by: 24. ADDITIONAL RIGHTS TO CANCEL. Signature: C N " IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: 1/14/2016 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after 1/14/2016. Customer's Name: If you don't sign this PPA and return it to us on or prior to 30 days after 1/14/2016,SolarCity reserves the right to Signature: reject this PPA unless you agree to our then current pricing. Date: Power Purchase Agreement SolarCity approved Signature: Lyndon Rive, CEO Date: 1/14/2016 i>C•.ac: :urc� ,se Agreer ,it,.... �r,3= ., '� U.,ii;:_r z0"_.`, ��� 42%>> Version#53.6-TBD SolarCity. January 25, 2016 N OF RE: CERTIFICATION LETTER N � Project/Job # 0101841 c Project Address: Le Residence 1 L CA 165 Prospect Ave 1 Northampton, MA 01060 p Q AH] Northampton SS NAL ANG SC Office Springfield 01/25/2016 Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05, and 2005 NDS - Risk Category = II -Wind Speed = 90 mph, Exposure Category C -Ground Snow Load =40 psf - MPI &MP2: Roof DL = 9 psf, Roof LL/SL = 28 psf(Non-PV Areas), Roof LL/SL= 28 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22462 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluationI certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. Digitally signed by Nick Gordon Date:2016.01.25 16:22:36-08'00' I(� uVirslJ<.•, `�;ln Platen (,!��td•,1;7 T (E;`>�L 6s5- t;:>5 (SNt i SOI-t_;ITY F((>°)Oj 635-10'9 :.ol�irciYy.c<x>> Version#53.6-TBD SolarCit . HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MP1&MP2 72" 24" 39" NA Staggered 44.6% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPI&MP2 48" 17" 65" NA Staggered 49.5% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MP1&MP2 Pre-Fab Truss @ 24 in.O.C. 22° Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. Sig( kzarview Way .S.rn PAa1, . (,A,),140:? T(W,M G38-1(Yt£i i8 Si Sf)1 CI fY F iG5Q'!C.€S-(02 3 lar(.�ty com fi STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1 & MP2 Member Properties Summary MP1 &MP2 Horhoopontal Member Spans Rafter Properties Overhang 2.82 ft Actual W 1.50" Roof System Pro ernes Span 1 7.25 ft Actual D 3.50" Number of Spans w/o Overhang) 2 Span 2 6.27 ft Nominal Yes Roofing Material Comp Roof San 3 A 5.25 in.^2 Re-Roof No Span 4 SX 3.06 in A3 Plywood Sheathin Yes Span 5 I 5.36 in.^4 Board Sheathing None Total Rake Span 17.62 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 3.50 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 15.83 ft Wood Grade #2 Rafter Sloe 220 PV 2 rt Fb 875 psi Rafter Spacing 24"O.C. PV 2 End F„ 135 psi ITop Lat Bracin Full PV 3 96rt E 1 1400000 psi Bot Lat Bracing At Supports PV 3 End Emig 510000 psi Member Loading Summary Roof Pitch 5/12 Initi I Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 9.0 psf x 1.08 9.7 psf 9.7 psf PV Dead Load PV-DL 3.0 f x 1.08 3.2 psf Roof Live Load RLL 20.0 psf x 0.95 19.0 psf Live/Snow Load LL/SL 1,2 40.0 psf x 0.7 ( x 0.7 28.0 psf 28.0 sf Total Load(Governing LC I TL 37,7 psf 40,9 psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(CO(IS)p9; Ce=0.9, =1.1, I5=1.0 Member Design Summary(per NDS Governing Load Comb I CD I CL CL - CF Cr D+ S 1 1.15 1 1.00 0.91 1 1.5 1.15 Member Analysis sults Summary Governing Analysis Max Demand I @ Location I Capacity DCR Result Bending - Stress -1492 psi 1 10.1 ft 1 -1580 psi 1 0.94 Pass n CALCULATION OF DESIGN WIND LOADS - MP1 &MP2 Mounting P ane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardwarej Comp Mount Type C Roof Slope 220 Rafter Spacing 24"O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h is ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 Psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC W 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh (GC) Equation 6-22 Wind Pressure U -13.1 psf Wind Pressure Down 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -223 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 44.6% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -247 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 49.5% ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERIIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. ) EXISTING 4.T ELECTRICAL METALLIC TUBING MEANS WMAY EBELEN ENERGIZED N OTHE OPEN POSF THE ITION,NG EMDCITY 0 F NORTHAMPTON FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE BUILDING DEPARTMENT GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY n HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. These plans have been reviewed I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL And Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). approved, Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC Date LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. Signature NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD T€SING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 PROPERTY PLAN PV3 SITE PLAN PV4 STRUCTURAL VIEWS LICENSE GENERAL NOTES PV5 UPLIFT CALCULATIONS PV6 THREE LINE DIAGRAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION Cutsheets Attached ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) J B—01018 41 0 0 ,PREMISE OVMER: DESCRIPTION: DESIGN: CONAL THE INFORMATION HEREIN JOB NUMBER: LEC N LE RESIDENCE Stefan Ste anovic 4\`!a CONTTAINEDAINEDSHALL NOT BE USED FOR THE p BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•.isolarCity.NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 165 PROSPECT AVE 7.28 KW PV ARRAY ., PART TO OTHERS OUTSIDE THE RECIPIENTS NODDLES: NORTHAMPTON MA 01060 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME: SHEET: REV DATE: Marlborough,Drive, MA Building 2, PERMISSOLARCSION EOF SOLAT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMIssION of saARaTY INC. SOLAREDGE SE6000A—USOOOSNR2 1111111111 COVER SHEET PV 1 B 1/25/2016 1 (866)—SOL-CITY(765-2489) www.solarcity.eom PROPERTY PLAN Scale:1" = 20'-0' 0 20' 40' J' J B-01 41 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE LE, C N LE RESIDENCE Stefan StepanovicBENEFIT SolarCity. NOR SHALL TNYONE EXCEPT BE DISCLOSED ISN WHOLE ORARCITY CIN M°"NnNGSYsTEM:ou 165 PROSPECT AVE 7.28 KW PV ARRAY ���� Comp Mount Type C PART OTHERS OUTSIDE THE RECIPIENT'S MODULES: NORTHAMPTON MA 01060 ORGANIZATION, IXCEPT IN CONNECTION WITH , 24 St. Martin Drtve, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME: SHEET: REV. DATE: Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER. T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—USOOOSNR2 1111111111 PROPERTY PLAN PV 2 B 1/25/2016 (8B8}—SOL-CITY(765-2489) www.solarcity.com PITCH: 22 ARRAY PITCH:22 MP1 AZIMUTH:291 ARRAY AZIMUTH: 291 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 22 ARRAY PITCH:22 -xN OF MP2 AZIMUTH: 111 ARRAY AZIMUTH: 111 N MATERIAL: Comp Shingle STORY: 1 Story G Front Of House i L 1 e NAL 1/25/2016 Ily signed by Nick Gordon ate: 016.01.2516:22:23-08'00' T d N LEGEND 0 (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS a DC JUNCTION/COMBINER BOX & LABELS u MP2 Fol DISTRIBUTION PANEL & LABELS ° I Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER ° p `, ; STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR AC O GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED r,_-i INTERIOR EQUIPMENT IS DASHED L_�J SITE PLAN Scale: 1/8" = 1' 2 01' 8' 16' F CONFIDENTIAL— THE INFORMATION HEREIN JOBNUMBER: JB-01 018 41 00 PREMISE OWNER: DESCRIPTION: DESIGN: ��� ■ CONTAINED SHALL NOT BE USED FOR THE LE, C N LE RESIDENCE Stefan Stepanovic --me. S BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .,,'r NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 165 PROSPECT AVE 7.28 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, NORTHAMPTON MA 01060 ORGANIZATION, EXCEPT IN CONNECTION IMTH ' 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-260PD05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE MAIN: SHEET: REV DATE Marlborough,MA 01752 INVERTER: T. (650)636-1026 F: (650)636-1029 PERMISSION of saARaTY INC. SERTER: GE SE6000A—USOOOSNR2 1111111111 SITE PLAN PV 3 B 1/25/2016 (866)-SOL-CITY(765-2489) www.solarcity.com S1 S1 -10" 7'-3" -3" 01 -10" 7'-3" -3" 01 (E) LBW (E) LBW A SIDE VIEW OF MP1 NTS B SIDE VIEW OF MP2 NTS MPJ X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 17" PORTRAIT 48" 17" ROOF AZI 291 PITCH 22 ROOF AZI 111 PITCH 22 TOP CHORD 2X4 @ 24" OC ARRAY AZI 291 PITCH 22 STORIES: 1 TOP CHORD 2X4 @ 24 OC ARRAY AZI 111 PITCH 22 STORIES: 1 BOT CHORD 2X4 @24" OC Comp Shingle BOT CHORD 2X4 @24" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) C(2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. OF (E) COMP. SHINGLE �{ (1 Vie. (4) PLACE MOUNT. moa' N (E) ROOF DECKING (2) G(5) INSTALL LAG BOLT WITHL U f� 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH 9�,r FIS NA WITH SEALING WASHER C6)1 BOLT & WASHERS. SS r1 EaU�� (2-1/2" EMBED, MIN) 01/25/2016 (E) RAFTER #_5T!�N� J B-01 01841 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: ����' ■ CONTAINED SHALL NOT BE USED FOR THE LE, C N LE RESIDENCE Stefan Stepanovic .,,SO�arCit}/ NORBENEFIT SHALL TNBENE EXCEPT DISCLOSED INWHOLEORARCITY CIN MOUNTINGSYSTEM: 165 PROSPECT AVE 7.28 KW PV ARRAY ��" PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: NORTHAMPTON, M A 01060 24 St. Martin Drive, Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-260PD05.18 PAGE NAME: SHEET: REV: DATE: Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. ISOLAREDGE SE6000A—USOOOSNR2 1111111111 STRUCTURAL VIEWS PV 4 B 1/25/2016 (886)-SOL-CITY(765-2489) www.solarcity.com UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 018 41 00 CONTAINED SHALL NOT BEE USED FOR THE LE, C N LE RESIDENCE Stefan Stepanovic ',1`SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �.. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 165 PROSPECT AVE 7.28 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON MA 01060 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Matin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME SHEET: REV. OATS Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER. T: (650)638-1028 F: (650)638-1029 PERMISSION of soLARarr INC. SOLAREDGE SE6000A—USOOOSNR2 1111111111 UPLIFT CALCULATIONS PV 5 B 1/25/2016 (668)-SOL-CITY(765-2489) www.sdaaity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE(SE6000A—USOOOSNR? LABEL: A —(28)TRINA SOLAR # TSM-260PDO5.18 GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:097562018 Inverter; 6000W, 240V, 97.57.; w Unlfed Disco and ZB,RGM,AFCI PV Module; 25OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER—HAMMER i 200A/2P Disconnect 3 SOLAREDGE Dc, SE6000A—USOOOSNR2 DC- —————— MPT:-1x16 (E) LOADS A L1 zaov ———————————— EGc -----� —--————————————————— �~ L2 DCr r 2 11 35A/2P EGC/ Dc. /-- A ---- OND -—-----------—-----------—---------- - GEC ---lN DG c MP2: 1x12 I B I GND EGC--- ---------------------�O)Conduit ------------- G ——————————————— 0 0— ——r� I N Kit; 3/4'EMT o EGCIGEC z I 1 I I 1 1 GEC 1 TO 120/240V I I SINGLE PHASE I I I I UTILITY SERVICE I I I I I 1 1 I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (1)SQUARE D HQM235 PV BACKFEED BREAKER A (1)CUTLER—HAMMER /DG222URB /r, PV (28)SOLAREDGE 300-2NA4AZS D� Breaker, A 2P, 2 Spoces Disconnect; 60A, 24OVac, Non—Fusible, NEMA 3R A PowerBox piimizer, 30OW, H4, DC to DC, ZEP —(/)Gro rtd Roo —(I CUTLER— AMMER !I DG10ONB nd (1)AWG/6, Solid Bare Copper 5/8 x 8, Copper Ground�Neutral Kit; 60-100A, General Duty(DG) —(1)Ground Rod; 5/8' x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEP11ON NO. 2, ADDITIONAL 'ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE I I _......_..__._ __......._-.._.....m._............_.._.. _.._....._.__...._..............._.._._.._ _._..._..............____.__.�..__.._._.._.._..._..__..._.._._. _._..__ __ __._._.._.____.__...__.._______.. _� _.._._.______..... _____._.._..................._._.__._..__ _..___._ ---..._...._._..--................_..._.__._____._.___._-_._-. __.__.....__..._._.___._..___.__.__......______.�____. (1�AWG /8, THWN-2, Black (2)AWG#10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O (1)AWG /8, THWN-2, Red O (1)AWG 16, Solid Bare Copper EGC Vmp =350 VDC Imp=11.73 ADC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=25 AAC (I)Conduit Kit;,3/4',EMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -(OAK#8-.THW472,,Green . _ EGC/GEC (1)Condult.Kit;.3/4'.EMT, . , . . _ . . (2)AWG#10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC O (1)AWG/6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.8 ADC (I)Conduit Kit:,3/4' EMT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I JB-01 018 41 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN TOB NUMBER: /� \,,`�OI���'�� CONTAINED SHALL NOT BE USED FOR THE LE, C N LE RESIDENCE Stefan StepanovicBEN NOREFIT OF SHALL ITYONE BE DISCLOSED EDN WHOLE ORT SOLARCITY CIN A10om srsou 165 PROSPECT AVE 7.28 KW PV ARRAY Awoj PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES NORTHAMPTON, MA 01060 THE SALE AND USE OF THE RESPECTIVE 28 TRINA SOLAR TSM-260PDO5.18 24 St. Martin Drive,Building 2 Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: �/ REV: DATE: T. (650)638-102Marlborou8 F: (650)638-1029 PERMISSION OF SOLARCITY INC. [NVERTER:OLA1 1 1 1 1 11 111 P V 6 B 1/25/2016 (888)-SOL-CITY(765-2489) www.solarcity.com SOLAREDGE SE6000A—USOOOSNR2 THREE LINE DIAGRAM CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 165 Prospect Ave INVERTER AND DC DISCONNECT UTILITY ----- SERVICE I I L-- AC DISCONNECT --------------------------� SOLAR PHOTOVOLTAIC ARRAYS) L--------------------- — J PHOT0V0LTAIC BACK-FED CIRCUIT BREAKER IN FAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0101841-00 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 018 41 00 PREMISE OMNER: DESCRIPTION: DESIGN: ■ CONTAINED SHALL NOT E USED FOR THE LE, C N LE RESIDENCE Stefan Stepanovic �,;SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., AMOUNTING SYSTEM: �..� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 165 PROSPECT AVE 7.28 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON MA 01060 ORGANIZATION, EXCEPT IN CONNECTION WITH ' 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-260PD05.18 PAGE NAME: SHEEP: REV DATE Marlborough,MA 01752 SOLARCnY EQUIPMENT, Wi7H0UT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE6000A—LIS000SNR2 1111111111 SITE PLAN PLACARD PV 8 B 1/25/2016 (8W)_SOL—CITY(765-2489) www.salarsitycom Label Location: Label Location: Label Location: (C)(CB) ® (AC)(POI) WARNING (DC) (INV) Per Code: _ Per Code: _ Per Code: NEC 690.31.G.3 ®• ® • • 1-® NEC 690.17.ETHE ELECTRIC SHOCK CONDUCTORS ®j NEC 690.35(F) Label Location: • _• - _," ® PHOTOVOLTAICTO BE USED WHEN PHOTOVOLTAIC (DC) (INV) ®"® , ' -• • INVERTER IS SE ENERGIZED DISCONNECT Per Code: �® W-• ® UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: • • ! •; "• • • (POI) MAXIMUM -• - (DC) (INV) Per Code: POINTPer Code: .-■ ■• • • NEC 690.17.4; NEC 690.54 .• VOLPOWER- NEC 690.53 • :• . •�. MAXIMUM SYSTEM ■ •- VOLTAGE -• •SHORT-CIRCUIT •- ! G• If CURRENT(Isr-)= Label Location: •- • WARNING (DC) (INV) Per Code: • ELECTRIC. NEC 690.5(C) •- -• . . Label Location: • ® •- CAUTION (POI) -• ® ® � DUAL POWER SOURCE Per Code: SECONDSOURCE NEC 690.64.B.4 PHOTOVOLTAIC Label Location: ♦ (DC) (CB) _ Per Code: Label Location: ■■ • . ® NEC 690.17(4) CAUTION (D) (POI) PHOTOVOLTAIC SYSTEM• :• . Per Code: •,' ',� aCIRCUIT IS BACKFE ■ NEC 690.64.B.4 Label Location: ♦ ® (POI) _ Per Code: ® Label Location: NEC 690.64.B.7• • PHOTOVOLTAIC (AC) (POI) Weak,• (AC): AC Disconnect • - • Per Code: •! (C): Conduit DISCONNECT NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect 0113 (AC) (POI) (LC): Load Center Per Code: (M): Utility Meter NEC 690.54 (POI): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR �� 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �: San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set �'.►►` T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE �� SolarCi� (888)-SOL-CIfY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 0 ^SolarClty ®pSolar Next-Level PV Mounting Technology ''^SolarCity ®pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs -...__ _-_.-_.____...-----..__ __....__ -�✓ i ms Cx: r Leveling Foot tirouM z Intartaak ; , , r .. ' Part No.850-1172 luwting Foot ETL listed to UL 467 i. ZapCompatflAt W Module "'.. Roof Attndmant Ilk ArrYyr Skirt y}11i,�� �in��, . Comp Mount Part No.850-1382 Listed to UL 2582 - tenting Rock tistet#fo ltl 2703. f" Q�°MVAT�e Description ,, PV mounting solution for composition shingle roofs FA m Works with all Zep Compatible Modules °01MP°s� Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" LISTED Interlock Ground Zep V2 DC Wire Clip Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" Ahab • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM • solar=ee solar= SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America (for 60-cell PV (for 72-cell PV (for 96-cell PV modules) modules) modules) INPUT P300 / P350 / P400 ® _ - -., Rated Input DC Powerf9 300 350 400 W _ Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vic T MPPT Operating Range 8-48 8-60 8-80 Vdc ., Maximum Shot Circuit Current(lsc) 10 _ Adc Maximum DC Input Current 12.5 Adc Maximum Efficiency 99:5 Weghted Efficiency 988 % Overvoltage Category ^' OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) 4 .,, .m. Maxi mum Output Current 15 Adc Maximum Output Voltage_ _ -_ _ _ __ 60 _. ..Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)_ Output Voltage per Power Optimizer 1 _ -Vdc N .. +. STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000 6 2,IEC61000 6-3 _ Safety IEC62109 1(class II safety),UL1741 ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage - 1000 .. -Vdc ,. Dimensions(W x L x H) 141x 212x 40.5/5 SS x8.34 x 1.59 mm/m _. ... ..... Weight(including cables) 95.0 gr/Ib Input Connector MC4/Amphenol/Tyco � �4 Output Wire Type/Connector Double Insulated;Amphenol xg �, Output Wire Length 0.95/3.0 1.2/39 m/ft Operating Temperature Range 40-+85/40 +185C /°F_., a .. ._ _... .._ ... ......._ '; a Protection Rating IP65/NEMA Relative Humidity _.. .... _... .._ 0- 100 __ _... _.�%�.... y aced STC Pow e 0tl of up 1. p e+ ancea owetl. %ow PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE MT - INVERTER 208V 480V SINGLE PHASE i(l1At8P k 1Zat �t 'llCfd4llo�ve .. MmmumStringlength(PowerOptimizers) _...... $...... 10 .._ UptcT25%mOfHtlnCrgy Maximum String Length(Power Optimizers) _...__ _. 25..__ ......_ 25 __.. ._.. 50 _...._. _ Maximum Power per String 5250 6000 12750 W —Superior efficiency(99.5%) _per _. ............ _ .... Parallel Strings of Different Lengths or Orientations Yes - Mitigates all types of module mismatch losses,front manuffacturing tolerance to partial shading — Flex#blesystemdesign for maximum space utilization — Fast installation with a Single bolt — Next generation maintenance with module-level monitoring — Module-leve[voltage shutdown for installer and firefighter safety .;sa aMArY ALY nlcE - JAPAN c1iNn sRAEL AUSTRALIA www.solaredge.us THE Vinarnount MODI.JILE TSM-PDO5.18 Mono Multi Solutions DIMENSIONS OF FV MODULE ELECTRICAL DATA r-STC unil:mm Peak Power Watts-Pm,x(Wp) 245 250 255 260 941 Power Output Tolerance-PAIAx 1%) E"o Maximum Power Voltage-Vmp(V) 29.9 30.3 30.5 30.6 mnaloN EGA Maximum Power Curreni(A) 8.20 8.27 8.37 8.50 THE Tir i na [wililn 0- u n t [NAMEPLATE- Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 -9,12 o Short Circuit Current-isa JA) 8.75 8,79 8.88 9.00 1NsrAUNG Marc Module Efficiency 9r,(%) 15.0 15.3 15.6 15.9 STC.Invadio nce 1000 w1ml,Cell Temperature 250C,Air Mass AM 1,5 according to EN 60904-3. MODULE Typical efficiency reduction of A.5%at 200 W/m'according to EN 60904-1 o Go ELEC-RI.A._DATA MOXIMUM POWer-P.AA(WP) 182 186 190 193 60 CELL Maximum Power V01talge-VAP(V) 276 28.0 28J 28.3 MULTICRYSTALLINE MODULE Maximum Power Current-(MPP(A) 6.59 6.65 6.74 6.84 WoEUNNoiE A- A Open Circuit Voltage(V)-Voc IV) 35J 35.2 35:3 35.4 ITH TRINAMOUNT FRAME Short Circuit Current(A)-isc(A) 7.07 7.10 7.17 7.27 fL I' I NOCT:Irradiance at 800 W/ri Ambient Temperature 20-C,Wind Speed I m/s, PD05.18 812 _+mT M i-2 6 OW Back View POWER OUTPUT RANGE MiECHANICAL DATA 11 Solar cells Multicrystalline 156 x 156 mm(6 inches) Cell orientation 40 cells f6-101 Module dimensions 1650 x 992 x 40 Tom(64,95 x 39.05 x 1.57 inches) Fast and simple to install through drop in mounting solution MAXIMUM,EFFICIENCY Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass A-A White Backsheet Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove I-V CURVES OF?VMODULE(245W) J-Box r IP 65 or IP 67 rated +A201 Cables Photovoltaic Technology cable 4,0 TPI(0.006 inches'), to.- 1200 Trim(47.2 inches) POWER OUTPUT GUARANTEE 9.---1-000wid"I Fire Rating Type 2 7 Highly reliable due to stringent quality control <6.. 80OW/r2 1. A>c,I ec7 ri,p g I cba I 4- /m2 TEMPERATURE RAT NGS "AAXIMUM.RATINGS C 1 r ercIc.or P, 2-'20OW/rn2 Nominal Operating Cell Operational Temperature 40-+85°C ,C d'j we�be 1 i eve,'.-Jos e 44-C(±2'C) ccor�Cri)[o-i"i.--n'�i-P'�'r'11 t'� Temperature NOCT) MaximumSystem 1000V DC(IEC) is -1 - 0�-L Temperature Coefficient of PsGe, 0,41%/'C Voltage 1000V DC UL 10.. 20.- 30.- 40°J -hone,'rni j5 Temperature Coefficient of Vat, 0.32%/'C Max Series Fuse Rating 15A c-lblc,provide se,wc-, Voltage(V) '�D"och ir.encr.n.-iorlve I Certified to withstand challenging environmental Temperature Coefficient of Isc U5VIC and y,.Ppl-rr�,nl ou.- r­lovifive, conditions p,�K)ble Teo, ­,",Alh'Iir�,rock l,".o. o WARRANTT 1rh t r,­�r ��L r ka b I fix"i vv-,or6- 10 year Product Workmanship Warranty 25 year Linear Power Warranty d tI (Please refer to product warranty for details) � b ,-I r'd ot t1i o b,:; li oi it si-tied mj�cgl-ss i CERTIFICATION LINEAR PERFORMANCE WARRANTY y P ---- ACKAGING CONFIGURATION or - -----___ 00-- <1 I 10 Year ProWa duct rranty A 25 Year Linear PoweWa r rranty Lam Modules per box:26 pieces Trina Solar Urnited --------- Modules per 40*container:728 pieces 3100% ........ 3� acifi .. a fflon E-A WEEP 90% CAUTION.READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT, E)"PAI, 8 • C2'O4 Trina Sol.,Limited.All rights reserved Specifications included in this dotasheatoesub ject to Trin-asolar ES 80% Trinajsolar change without notice, S , ' Sm.ft Energy Fogeth,�.- Years 5 10 is 20 25 mart ou-1­ 0, in NJ THE Vinamount MODULE TSM-PDO5.18 Mono Multi Solutions DIMENSIONS OF Pk`MODULE r ECTRlCAlA)ATA d STC sjn;f'mrrr Peak Power Watts-P­(Wp) 250 255 260 265 941 Power Output Tolerance-P­x(%1 0­3 Maximum Power Voltage-VP IV) 30.3 30.5 30.6 30.8 ecx Maximum Power Currel(A) 8,27 6,37 81$0 8,61 THE Tinnal 11 U1 It Open Circuit Voltage-Vac(V) 38.0 38.1 38.2 38.3 -4 Short Circuit Current-Ise(A) 8,79 8.88 9.00 9.10 Module Efficiency ii(%) 15-3 15.6 15.9 16.2 1 STC Irradiance 1000 W/m',Cell Temperature 25"C,Air Mass Arvil.5 according to EN 60904-3. MODULE Typical efficiency reduction of 4-57 at 200 Wlm'according to EN 60904- o _j DArA sc�sl Maximum Poi(Wp) 186 190 193 197 60 ,CELL Maximum Power Voltage-V,,r(VI 28.0 28.1 283 28.4 Maximum Power Current (A) 6.65 6.74 6-84 6.93 MULTICRYSTALLINE,MODULE PDO5.18A -A Open Circuit Voltage(V)-Voc(V) 35.2 36.3 35.4 35,5 WITH TRINAMOUNT FRAME Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 NOCT:Irradiance at 800 W/ml,Ambient Temperature 20°C,Wind Speed 1 m/s. 812 0 ilft 65 W Back View t0i""'HANICAL DATA POWER OUTPUT RANGE Solarcells Multicrystalline 156-156 mart(6 inches) Cell orientation 60 cells(6 10) Fast and simple to ill through,dmp in mounting solution Module dimensions 1650-992=40 mm(64.95-39.05 x 1.57 inches) oelx Weight 19,6 kg(43.12 lbs) 16.27o ------------------------------ Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY A-A Backsheet White Frame Black Anodized Aluminium Alloy Good aesthetics for residential applications 1-Box.. IP 65 or IF 67 rated Cables Photovoltaic Technology cable 4.0 (0.006 inches'), 00%0+3% mm'........... 1,V CCIJRVH�OF PV MODULE(26OW) 1200 mm(47.2 inches) POSITIVE POWER TOLERANCE Connector H4 Amphenol Fire Type UL 1703 Type 2 for Sol.,City Highly reliable due to stringent quality control Iris 1 ",vz, V 1A A X I M 13 PA IF A I N­S Nominal Operating Cell 44°C f±2'C) 40-+g5°C Operational Temperature -40 P�Z�),�J,."t,� bcl Temperature(NOCT) Maximum System Il DCIECJ 1t, %vith J 'Q Temperature Coefficient of P- -0.41%/'C voltage I000V DC(LIQ ;h',r glc.A-) ,T"I,—is Temperature Coefficient of Voc -0.32%/OC Max Series Fuse Rating 15A ------- Certified to withstand Challenging environmental la M 3o Temperature Coefficient of Ise 0,05%/,C conditions 4 Y,i j 10 year Product Workmanship Warranty CERTKtCATION a�,Fv 25 year Linear Power Warranty (Please refer to product warranty for details) Ilia. g Sri,)rf LINEAR PERFORMANCE WARRANTY EE TrA �� 0, C�ANS CNFIGURAIJON EU-28W ........... 10 Year Product Warranty-25 Year Linear Power Warranty Modules per box:26 pieces Tina Solar Unified ------ ..........I ------ Modules per 40'container!728 pieces 6100% 90% Solara linear, CAUTION. READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. I he Q 20 5 Tr mited,All rights reserved.Specifications included in this datasheet are subject to Set-' 80% ri-go without notice. Trinasolar Trin-asolar Year, 5 10 15 20 25 so I a rME6 '" Single Phase Inverters for North America so I a r ! _ Y" SE3000A-US J SP -US J SE5000A-US{SE6000A-I S SE760OA-US/SE 10000A-LIS/SE11400A-US SE3000A US iSE380OA-US SESOOOA-US SE6000A US SE7600A US SE10000A US SE11400A Us _.. ._._... ._.. __.. .... .._ ........ ... ._-- _ _. OUTPUT SolarEdge Single Phase Inverters . _ .100.09 (1a 240V 9980 @ 208V Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA . 5400 @ 208\/ 10800 @ 208V For North America Max.AC Power Output 3300 4150 6000 8350 12000 VA s4so @2aov 10950.4D240v AC Output Voltage Min.-Nom:Max I'€ ✓ 183-208 229 Vac SE300OA-US SE380OA-US S 500OA-US SE6000A-US _ AC Output Voltage Min Nom.-Maz h � � � � ✓ ✓ � ! SE760OA-US l Srtaa aA-US SE1140OA-US 211-240 264 Vac _ AC Frequency Min.-Nom.-Max.(" 59 3 60-60.5(with HI country,setting 5 60-60.5) ,Hz Max.Continuous Output Current 12.5 16 24 208V .25 32 AS @ 208V 47.5 A 21 240V 42 @ 240V " GFDI Threshold 1 A Otter' R,£2k f ;`Y Utility Monitoring,Islanding Protection Country Configurable Thresholds Yes _ Yes INPUT Maximum DC Power STC 4050 ' 5100 6750 8100 10250 13500 15350 W iransformerless Ungrounded.,. ..... ..... ._..Yes _. ...... _..... ... _. Max.Input Voltage .., ...... ...500.. .. ..... _...... Vdc ... .... .. ... ... a�12 ^x Nom.DClnputVoltage _ .,... ., ,,.325@,208V/350@240V.._.... . . .,. Vdc,,,. 16.5 @ 208V I 33 @ 208V ;- „°, Max.Input Current"' 9.5 13 18 23 34.5 Adc }«... �. .,,m,... ....... ... .,... __.. ... ...._ :5.@,74 _... .,.. ....._ :?.�° 240 15 OV 30 V Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection _... ...., ._ _ ... Yes .. ... .. .,. Ground-Fault Isolation Detection I 600ku Sensitivity - - - - - '. ,. ,,, 977 9.8..2. 98.3 983 98_., 98.. _._ 98 ,. Maximum Inverter Efficiency, � ..... .. .. 97.5 @ 208V _ 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.!i 97.5 98 @,240V 975@240V .. tf .,. �. ... .. ...... - Niy+httime Power Consumption i <2.5 _ <4 _ W ADDITIONAL FEATURES Supported Communication Interfaces ., RS485,RS232,Ethernet,ZigBee(optional) Revenue Grade Data,ANSI C12.1 .. Optionali3; ..._ r >YI ?s ........ ....... .... .. .. .... ... . . Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installedj°i - STANDARD COMPLIANCE - - - - -- _ u 3"` - ' - � :�, Safety,.,. --.__ -- ---- - UL1741 UL16996 UL1998,CSA 22.2,. T - �- Grid Connection Standards IEEE 1547 INSTALLATION SPECIFICATIONS 3 P... t^ L 3 Emissions FCC art15 class B d .._ _ - -_. AC output conduit size/AWG range i /4"minimum/16 6 AWG 3/4 minimum/8-3 AWG '� trot DC input conduit size/If of strings/ 3/4 minimum{1-2 strings/ 3/4 minimum{1-2 strings/16-6 AWG j -. AWG range... _._ ... ...... .. ... .. .... .... ...., .... ...14-6 AWG. i ... .. ' € Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/ a - ( 30.5x 17.5x7.2/775x315x184 a it= 775 x 315 x 260 mm WePght with Safety Switch ._.I 51.2/7.3 2 - - 54.7/24.7 88.4/.40.1 . _ _ Ib/,kg Natural n -, ., convection Cooling Natural Convection and internal Fans(user replaceable) fan(user NOW replaceable). " itFr a1rEdg 'Irl sit N _ ,. - t oise ..�.. <25. .I_ <50 dBA li a rx'S'tGd al`iw�' protection @' ytC#r% 2q1 �,.ca lial3irE` '. n Max.Operating 7ernpereture Isi M€ 13 to 140/ 25 to 60(40 to 60 version available ) 'F/-C 'Superior effin98`ra Range . '= ,.Protection Rating A ng NEM3R , p .e.... .. ..... ..... _ ._...... ......... . ... _ ..., ..._.. ......_. Small,lightweight andeeasy winatall ow provided Raracttet n€For other reg onal settings Please­t,ctS,1,rEdg­ppmrt. €'€A h ighe,current source may be used;the-nverter will mu is-nput current to the values stated. -: Built-in mo, Ile-level r t� s Ing Revenue grade inverter P/N SE....A USOOONNR2(for 760OW-nverter'SE760OA-US002NNR2). D n°€ Rapid shutdown kit P/N.SE1000 RSD Sl. •, Internet,connectton-through Ethernet or Wireless ; �0 version P/N SExx A-USOOONNU4(for 760OW inverter:SE760OA-US002NNU4(. Outdoor and indoor installation -r fixed voltage inverter,AC/AC conversion only Pre-assembled Safety Switch for taster installation Optional-revenue grade data,ANSI 012.1 sL sa c USA-GE:RMANY-'IALY-FRANCE -iAPAN-CHINA-AUSTRALIA r I I IN:THE:RLAN DS-1SRAE:E. www.Solaredge.US