12C-049 (2) solar a r=@@ Single Phase Inverters for North America s o I a r _ _ SE3000A-US/SE380OA-US/SE500OA-US/SE600OA-US/ SE760OA-US/SE10000A-LIS/SE1140OA-US SE3000A-US SE3800A 800A-US SE5000A-US 'SE6000A USI SE7600A USA SE1000 OA-US SE11400A US L OUTPUT.:.... ...... SoIarEdge Single Phase Inverters . Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA 0800 @ 208V Max AC Power Output 3300 4150 . 5400 @ 208V 6000 8350 1 @ 12000 For North America Voltage 5450�240� _ ]095D@24gy VA . .. ._._.... ..... i.... .._. AC Min:Nom Max.i'� i 183-208-229 Vac SE3000A-US/SE380OA-US/SE500OA-US/SE600OA-US f AC Output Voltage Min.-Nom.-Max."' _ _.✓ ✓. _f _ _ ✓ _.. ✓. _✓ _ _✓ __ 211 240-264 Vac SE7600A-US/SE10000A-US/SE11400A-US AC Frequency Min.Nom Max(') 59_.3-60 60.5(with HI count.y setting 57-60-60.5) Hz _.. . . . - 24 @ 208V -... - 48 @ 208V Max Continuous Output Current j 12.5 16 1 25 32 47.5 1 A ,�;. _. ___ ....... .. .. I. 21924 .. -40 i.. tz' GFDIThreshold _.... _ _.. .1 A Utility Monitoring Islanding Protection Country Configurable Thresholds Yes Yes __ .- ---- .... _. _.. .._- -. _.. ! :a INPUT ; - ----.. --_. ..... _-._... -.-- .. .... .. .. .. ... r._. Maximum DC Power(STC) 4050 � 5100 6750 81.00 ...10250 13500_ 15350 � W., F. Tran former-less Ungrounded Yes i g, Max Input Voltage 500 Vdc Ile 1�8� Nom DC Input Voltage ,., 325 @208V/350 @240V. - .,.-, ...f.. Vdc ....... ..... .. ... .. .16.5 @ 208V . . 33 @ 208V ...... ` a t Max.input Current(2) 9.5 13 18 23 34.5 Adc 5A „ ltlb.. P 15,5,�1a.240V .... .. .. ... ..... 30.5 @ 240V. ..... ;.4 ( Max Input Short Circuit Current ........ ............. .._.-.. .45 ..........__..... i...Adc.... Reverse Polarity _ Yes ". �' .... ... Protection _... .. ...... ...._. _... ..._.._............_... ...... Y .._ ....._. Ground-Fault Isolation Detection 600ko Sensitivity _ Maximum Inverter Efficiency ., 97.7 .982 98.3 . 98.3 98 98 - - 98 / ... .. .. __... ... ..... ...... ... ... 1. - 97.5 @ 208V 1 97 @ 208V I ' 97.5 98 97.5 97 5 97 5 i / e; CEC Weighted Efficiency @ 24 97.5 n + , Nighttime Power Consumption ..., <25 .... .. -.._ _. <4 ..._—_ ...._. W._. _ x� ADDITIONAL FEATURES ................ .— �__ .............._ .._.__ ._.... ....... Supported Communication Interfaces RS485,RS232,Ethernet ZigBee(optional) Revenue Grade Data,ANSI C12 1 ) Optional)) 1 *' Rapid 5 enabled when SoIarEdge rapid shutdown kit is Installed(°i Shutdown NEC 2014690.12 � Funcnonalitye_ � _STANDARD COMPLIANCE __ _ _ _ ... .. __.. . . ._-. ,Safety_ _.,. .. UL16996,UL1998, Cnd Connection Standards IEEE1547 UL1741 CSA 22 Emissions..._.. ........ ) .. .. FCC part15 class 8_ .... 1.... . ....... __....... .... ._._. INSTALLATION SPECIFICATIONS _ y - -- - - -— - — - - ° € u AC output conduit size/AWG range _ 3/4"minimum/16-6 AWG 3/4'minimum/8-3 AWG DC input conduit size/#of strings/ 3/4'minimum/1-2 strings/ 3/4 minimum/1-2 strings/16-6 AWG ] 146AWG s with Safety ..... _. ... ..... _._. ..... 'r Dimension ety witch S 75 3 5x120 5/ mint r z "" LHxWxD) 305x 12.5 x72/775x315x184 - - - m - 11 Weight with Safety Switch 51.2/23.2 ._ ..I. 54.7/,247 88x4/40.1_ Ib/kg.,. a q x .,f .. ....... .._.. _ (....Natural .._ convection f ,9 .. Cooling Natural Convection and internal Fans(user replaceable) �� , .° fan(user .. replaceable) n x . 'lk ,'31 '6 -. "��,' '" � Noise.................. .L, <.25. �_ <90. .i...dBA Mte ed. a r r M '1 �xDr("�.�• 1 4 y y ; - ��s �` - x.Operating p nature - 3 to+140/-25 to+60(-40 to+60 version available"') ` '«'r. 3:; `.. -, - Rain e e ....... ...................... ......... ti�drM99`c g. .. . . . .. _._. ........... .._._... . ............. . j Protection Rating. .. ... .... . ........_.............._.............._.._.._.....NEMA 3R _.._ _-....,....................._........ ....!........... Temperature 1 �y y r' r}tj0r�iig '�(dl,e 5,v',I�tall,fli o--,, li d b ,,,ke – I'I For other reg onal settings please contact SoIarEdge suPPOrt € h'gher current source may be used,the'nverter­11 rm t it,nput current to the values stated. •r i rift in. IOdu E:�deve4Aonitor �, _ 1si Revenue grade'nverter P/N SEx...A U5OOONNR2(for 7600W Inverter.5E7600A US002NNR21. °)Rapid shutdown kit P/N SE1000 RSD Sl � tLa"rrr y(rlrl ,` � iiDugh Ethernet or Wire-ti�s; <._.. `. � 40version N.SExxxx/US"NNU ' 0W nverter SF760 IJS002NN Outddtr and indoor FnstMifiati[n ` Fixed volts inverter,D C conversion only Pre-assembled Safety Switcb for faster installation Optional—revenue grade data,ANSI C122I sunsc� • oH USA-GERMANY-ITALY-FRANCE-iAPAN-CHINA-AUSTRALIA-THE NETHERLANDS ISRAEL. www,SQlaredge.US THE Vnamount MODULE TSM-FDO5.18 Mono Multi Solutions DIMENSIONS OF PV MODULE ELECTRICAL DATA'4 STC ,Jnq:mm Peak Power Watts-P­(Wip) 250 255 260 265 941 Power Output T*Ierafrice-PlAx J%J 0-+3 Maximum Power Voltage-V­(V) 30.3 30.5 30.6 30.8 JUNCTM maximum flower Current-l-P(A) &27 8,37 8.50 8.61 THE Open Circuit Voltage-Vac(V) 38.0 383 38.2 38.3 rina r iiiiiin o u n ­12 I Short Circuit Cuffori(A) 8.79 8.88 9J0 Module Efficiency rlm 15.3 15.6 15.9 16.2 ITC Irr-cr....llj.0Wlnn',Cell Temperature 25°C,Air-.,s -1.1 according Is,11,091A-3 MODU LE Typical efficiency reduction of 4.5%at 200 WIrri according to EN 60904-1. 'i DATA P NOCT Maximum Poi(Wp) 186 190 193 197 Maximum Pcwervbttage-v w(V) 28.0 28.1 28.3 28,4 40,tl­ ELL Maximum Power Current-Impi,(A) 6.65 6-74 6-84 6.93 MULTICRYSTALLIN"ODULE A Open Circuit VottalgiB,(V)-V.a(V) 35.2 35.3 35,4 35.5 PD05.18 WITI 1 4 TRIN Short Circuit Current(A)-I.(A) 7.10 7.17 7,27 7.35 AMOUNT fRA"_' 20°C,Wind Speed I m/s. NOCT:Irradiance at 800 W/m',Ambient Temperature 20 205w, Back view HANICAL DATA A- A ,GE POWER,OUTPUTR 14 Solar cells multicrystailine 156 x 156 Trim(6 inches) Cell orientation Fast and simple to install through drop in mounting solution 60 cells(6-10) Module dimensions 1650 x 992-40 mm(64.95 x 39.05 x 1.57 inches) 11.6 kg(43.12 lbs) Weight Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY Backsheet White A-A Frame Black Anodized Aluminium Alloy Good aesthetics for residential applications J-Bax IP 65 orIP 47 rated 0,0 3 Cables Photovoltaic Technology cable 4.0 MM2(0.006 inches'), 1200 man(47.2 inches) 0 + 70 I-V CURVES Of PV MODULE(26OW) Connector H4 Amphenal POSITIVE FOWER TOLERANCE f-i Fire Type UL 1703 Type 2 for Solar City Highly reliable due to stringent quality control AXIM UM A R � TEMPERATURE RATINGS M or, A- -1 h c"t, Nominal Operating Cell Operational Temperature 40-+85°C 44-C(±2-C) pi'Ocl- do's- Temperature(NOCT) MaIxImurn System 1000VOCKC) Ic of, oi mofl'-)ws ------------- 0.41%/'C Voltage IDOOVDC(UL) ------------------- .....--------------I Temperature Coefficient of P� i C.r It t c,S L cc­S. W th 10-' Temperature Coefficient of Voc 0.32%/'C Max Series Fuse Rating 15A prf�,­_­nce ai,Cmd-hc�globe, 0.05%/'C Temperature Coefficient of kc o to 50 7 h,"eu_h cu'slo'"Iri;n r), Certified to withstand challenging environmental --nto conditions I e T) d c t 14 rl,.,-,,0 WARRANT, of Hirl<l os a no!n'l vi"b",ci covrrirni Ite, CERTIFICATION 10 year Product Workmanship Warranty T,b 11, 0's ro ee " j: 25 year Llroiijar Power Warranty b c cst (Please refer to product warranty for details) parrney,CIE Th r,r� PACK AGING CON FIGUFA N M;1"S LINEAR PERFORMANCE WARRANTY `, E � --------- Modules per box:26 pieces ..........L---------- ........................ 10 Year Product Warranty 25 Year Linear Power Warranty Ttin 11 Solve Urnifed ---- -­ --------------- ..........------- .......... Modules per 40'container:728 pieces 0 90% Warr Or ant CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT 2 C 2015 Tu without SolarnLimited All rights reserved.Specifications included in this datasheet are subject to change ithout or- Trin-asolar 0'807 Trin-asolar e Years 5 10 15 20 25 M ' k THE VinamountM,,0DULE TSM-PDO5.18 Mono Multi Solutions DIMENSIONS Of FV MODULE zLECTRI^AL DATA y,STC unif`f§l'm. Peak Power Watts-Pmnx(Wp) 245 250 255 260 941 --- -- Power Output Tolerance-PMnx{%j 0°+3 Maximum Power Voltage VMP(V) 29.9 30.3 X5 30.6 THE Trina , , i(ritunt I E Maximum Power Current IaeP(A) &20 8,27 8,37 &5o !"TE o Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 INST-ri NOtE Short Circuit Current•(sa{Ai 8.75 8.79 8.88 9,00 a Module Efficiency rl 1%), 15.0 15.3 15.6 15.9 STC Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. 1 Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. o In i - ro m b - o ELECTRICAL DATA q NOCT ELL Maximum Power-P-(Wp) 182 186 190 193 I Maximum Power Voltage-Mv,(V) 27.6 '..28,0 28.1 28.3 [R3ULTICRYSTALLINE MODULE s-m<.,GnounowGHOEE Maximum Power Current-IMPP(A) 6.59 6.65 6.74 6.84 � � T FRAME -0nMneaE A A Open Circuit Voltage(V)Voc(V)' 351 35,2 35.3: 35,4 Short Circuit Current(A)-lsc(A) 7.07 7.10 7.17 7.27 NOCT:Irradiance of 800 W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. -, PD05.18 812 � 780 24 I Back View POWER OUTPUT'I!ANNGE MECHANICAL DATA Solar cells Multicrystalline 156 x 156 mm(6 inches) Fast and simple to install through drat in mounting solution cell orientation 60 cells(6 x 10) oc"K Module dimensions 1650 x 992 x 40 mm(64.95 x 3905 x 1.57 inches) • - -- -- -- - Weight 21.3 kg(470lbs) MAXIMUM. FF CIENCY K Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass A-A Saaksheet White Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove I-V CURVES OF PV MODUrE(245 ) J-Box IF 65 or IF 67 rated Q Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), ____. ...... .._......._.. _...... .._ .._. Ion .- 7200 mm(47 2 inched Pf3WTllrtGllARANTEE - 9-.-a�w7 __ - 8 Fire Rating Type � - Highly reliable du to stringent quality control <6° SOOW/tn' 6ww/., r a gl t i n a4 t u 4 �- TEMPERATURE RnT N 1 C = _ ? _ C,' 499w4m GS fAXPAUt�RA ZINGS c t >yi c - - - -20W - - Operational Temperature erature 40-+85°C( u :1. I j Nominal Operating Cell 44-C(±2'C) oo oirc ut - Temperature(NOCT) MaximumSysl� t000VDC(I EC )1 ? V itil Ir l Temperature Coefficient of P.. 0,41%]'C Voltage 1000V C QUI.)o:0.. 10.- 20,° 30.m 40m ( " � ffi ((` r r(C a volfage(V) Temperature Coefficient of Voc 0.32%/1C Max Series Fuse Rating 15A r)• a.�t T 1 �r"'s C) � L � r Ih v , l .e1Cja f rnerfr nnarke'4 Certified to withstand challenging environmental Temperature coefficient of Ise 0105%r°C conditions xr jbIle p cu- it thie t' ciy.iz; [ _. t Tril,1 a of E-Ono,3.,orka!D'r- WARRANTY f artner. yrfre r, -tnr 1 (-,rd 10 year Product Workmanship Warranty tO budOing r.`7 g riEne al!thoborotiorlvvgh 25 year Linear Power Worronty „.ca pe .,.);.,trier Jtot5, .. ., (Please refer to product warranty for details) G.(C1 o t r par-ne s S the _ #'s nF of i s{ 7I d J .,C -:rl CERTINCATION... oriving an lr �,Tcn ,(1_. LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION e®� �._._.._..._........,_...,... ._.._.v. ( YEQr tQICt YLTGQ7t} gT Ci1QY Power WgtTtnty LIMP e G Modules per box:26 pieces a' w Trina Solar Limited ..._.._. ._,_......-__._...,,„. .°.....____e_e....._ ._.�. D Modules per40'container:728 pieces Ad 31H-11 1 - at Us,fr o Eil�weEe f0 90% r7g C1 Sa¢gyrS linear warrah,y CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. poT"PA Tje 1 80% ©2014 Trina Solar Limited.All rights reserved.Specifications included In this datasheet are subject to II€€ change without notice. rxaartEnir'rgy5�a.->=then Years 5 10 15 20 25 l -r`T MPP tyey O I solar ' • so I a r=@@ SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer _ P300 P350 P400 -- Module Add-On For North America "°`�-aeIIFV "°`odue "otodulel°" modules) modules) modules) I INPUT P300 1 P350 / P400 • Rated Input DC Power' 300 350 , 400 W ® Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc MPPT Operating Range 8 48 8-60 8-80 .Vdc, Maxi Short C€rcwt Current Qsc) I 10 Adc Maximum DC Input Current __ .. ..12.5 ._.... .._ Adc_.. ;. Maximum Efficiency _. .....99.5 %. ' ,. ,,,,',•-�. Weighted FSticiency _... 98:8 eY Overvoltage Category :ry OUTPUT DURING OPERATION(POWER OPTIMIZER CONNE_CTED TO OPERATING INVERTER)_ Maxium Output Cut 15 Adc m rren Maximum Output Voltage _60 _ _I Vdc t °n, OUTPUT DURING STANDBY(POWER OPTIMIZER DISCO r�°,'^a ,, °;r,€e .n a • _ T - NNE CTED FROM INVERTER OR INVER_.TER,O_FF_) Safet Out ut Volta Vd_c_ _ ...__ _— _ .....P e e erO Hmizer .._ ._.. ,,.,. STANDARD COMPLIANCE - *' EMC FCC Part15 Class R,IEC61000 6 2,IEC61000 6-3 l ,.,. =ry;,,; d�, „ .. �', SOIafCity ZepSolar Next-Level PV Mounting Technology -SOIafCity Zep Solar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs ( w w Leveling Foot (iromW Zep - tff6arta[slt ?CCy sak,+�*nu - `~` ,. "�•. ram �evrtl lace PartNo.850-1172 w € ETL listed to UL 467 - .. _v.t� e �� 1 v-` I rl Zoo compallill W IAodde Hw,r. Zep®roars Root Attacernent e Min SlOrl t,�,n,,,,,,,r Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 Ah GOMPAT'6 Description PV mounting solution for composition shingle roofs AO Works with all Zep Compatible Modules VOW CUMPP�� Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type V or"Type 2" Interlock Ground Zep V2 DC Wire Clip �L LISTED Specifications Part No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 am AR • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM WARNING:PHOTOVOLTAIC POWER SOURCE Label o a o Label, -•Location: Label Location'.• -- Code- WARNING _ (• _ WARNING �_ Code: NEC EtEGTRIG SHOCK HAZARD ELECTRIC SHOCK HAZARD • NEC 690.31.G.3 DO`NOTTOUGH TERMINALS 1 THE DC CONDUCTORS OF THIS 1 WHEN Label . • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE • = � LOAD!SIDES MAY BE ENERGIZED UNGROUNDED AND PHOTOVOLTAIC DC {N THE ppEN pOS{TION MAY BE ENERGIZED UNGROUNDED Per Code: NEC DISCONNECT ••1 Label Location: Label _ PHOTOVOLTAIC POINT OF (POI) INTERCONNECTION MAXIMUM POWER--A _WARNING: ELECTRIC SHOCK Code: POINT CURRENT(Imp) Per Code: HAZARD. DO NOT TOUCH 690.17.4; 690.54 MAXIMUM POWER--� 690.53 BOTH THE LINE AND LOAD SIDE Lab MAXIMUM SYSTEM V MAY BE ENERGIZED IN THE OPEN VOLTAGE(Voc)� POSITION.FOR SERVICE SHORT-CIRCUIT A DE-ENERGIZE BOTH SOURCE CURRENT(Isc)- AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AG A OPERATING CURRENT - MAXIMUM AG V _I Location: OPERATING VOLTAGE ...WARNING DCode: ELECTRIC SHOCK HAZARD � -90.5(C) IF A GROUND FAULTiS INDICATED NORMALLY GROUNDED Label L• - • CONDUCTORS MAY BE CAUTION • UNGROUNDED AND ENERGIZED DUALPOWER SOURCE Per Code: SECOND'SOURCE IS NEC 690.64.B.4 PHOTOVOLTAIC-SYSTEM Label • • WARNING Location: ' kT ELECTRICAL SHOCK HAZARD CAU I I O N -• DO NOT TOUCH TERMINALS •1 TERMINALS ON BOTH LINE AND Per Code LOAD'SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFED 690.64.B.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • INVERTER OUTPUT Label Location: 690.64.B.7 CONNECTION Disconnect PHOTOVOLTAIC AC (AC) (POI) DO N'OT RELOCATE DISCONNECT ••- THISODEReERRENT Conduit Per NEC 690.14.C.2 (D): Distribution Panel Disconnect (IC): Int • Conduit Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AG • •'' OPERATING CURRENT - A Per _ _ MAXIMUM AC V NEC 690.54 - OPERATING VOLTAGE � •• -• • • • 3055 Clearview Way San Mateo CA 94402 F 1 1• 1 1 1 1 1 1' 1 1 F '• 1' 1 . 1 1 Ip 1 1 1 •1 1' mfogm 1 1 1 1 1' LabelSet- 1 1 Y 7 1 1 1 w r CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 260 N Maple St INVERTER AND DC DISCONNECT AC DISCONNECT r—� UTILITY SERVICE r--------------------------' SOLAR PHOTOVOLTAIC ARRAYS) L--------------------------J PHOTOVMTAIC BACK-FED CIRCUIT BREAKER IN FAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0101874-00 CONFIDENTIAL— THE INFORMATION HEREIN ,1013 NUMBER: PREMISE ONNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-0101874 00 ■ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: BUUCK, MARILYN BUUCK RESIDENCE Rich Choza :�,;;SD�arC�}` , NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp ount Type C 260 N MAPLE ST 2.6 KW PV ARRAY A' . PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (10) TRINA SOLAR # TSM-260PDO5.18 24 Si.Martin Drive,Building 2 unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV DATE: T. (650)636-1028 : (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3000A—USOOOSNR2 (413) 585-5181 SITE PLAN PLACARD PV 8 1/25/2016 (BBB)—SOL-CITY(765-2469) www.sOorcity.aam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE ## SE3000A—US00OSNR2 LABEL: A —(10)TRINA SOLAR TSM-260PDO5.18 GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:98643887 Inverter; 300OW, 240V, 97.5%q 25 w/Unifed Disco and ZB,RGM,AFCI PV Module; OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 125A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 CUTLER—HAMMER 10OA/2P Disconnect 2 A SE3000AUS000SNR2 (E) LOADS A LI z aov L2 N 1 DC+ 20A/2P ____ GND EGCI ___ DC' ------------------------------------- --- -------- MP2:-1x10 GEC T N D - I C DC- cc 13) PN ----I GND EGC ---------------------------------- �L_hj I o EGCIGEC 1 I I i I � GEC TO 120/240V I I SINGLE PHASE i I I UTILITY SERVICE I I I I I I I I I 1 I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (1)SIEMENS/0220 PV BACKFEED BREAKER A (1)CUTLER—HAMMER /DG221UR6 /fj Pv (10)SOLAREDGE�300er, 300 ZS DC Breaker, 20A/2P, 2 Spaces Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R /1 PowerBox timizer, 300W, H4, DC to DC, ZEP —(2)Gro qd Roo —(1)CUTLER—HAMMER i DG03ON8 1 AWG Copper 5r8 x 8, Copper Ground/Neutral it; 30A, General Duty(DG) n ( ) /6, Solid Bare —(1)Ground Rod; 5/8' x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ;ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE i I I 1 AWG #10, THWN-2, Black (2)AWG /10, PV Wire, 60OV, Black Voc* =500 VDC Isc —15 ADC OL_L(1)AWG/10, THWN-2, Red j O (1)AWG #6,'Solid Bore Copper EGC Vmp =350 VDC Imp=7.33 ADC "` (1)AWG/10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=12.5 AAC . . . . . . . . (1)Conduit Kit;.3/j' EMT. . . . . . . . . . . . . . . . . . . . 7(1)AWG y8,.TFlNM-2,,Green . _ EGC/GEC.-(1)Conduit_Kit;.3/4",EMT. . _ . . . . . . . l I 1 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN NUMBER: J B-0101874 00 Rich Choza \`!!SolarCity. CONTAINED SHALL NOT BE USED FOR THE BUUCK, MARILYN BUUCK RESIDENCE �,,, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: A., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 260 N MAPLE ST 2.6 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULE: FLORENCE, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 SL Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (10) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME: SHEET: REV: DATE: Mariborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN [INVERTER: T. (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCTY INC. OLAREDGE SE3000A—USOOOSNR2 (413) 585-5181 THREE LINE DIAGRAM PV 6 1/25/2016 (SBS)-sa-clTr(765-2489) www.salaraity.aam UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL— THE INFORMATION HEREIN [JOB NUMBER: J B-01018 7 4 0 0 PREMISE OWNER: DESCRIPTION: DESIGN:CONTAINED SHALL NOT BE USED FOR THE BUUCK, MARILYN BUUCK RESIDENCE Rich Choza 'BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NTING SYSTEM: �.,S���f City NOR SHALL IT BE DISCLOSED IN WHOLE OR IN om Mount T e C 260 N MAPLE ST 2.6 KW PV ARRAY ►,PART IZ OTHERS EPTIDE THE RECIPIENTS ULE: FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION N11H r THE SALE AND USE OF THE RESPECTIVE 0) TRINA SOLAR # TSM-260PD05.18 24 St. Martin Drive, Building 2 unit 1t SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN RTER: PAGE NAME: SHEET: REY DATE T: (650)638-1028 MA(650)638-1029 PERMISSION OF SOLARCITY INC. OLAREDGE SE3000A—USOOOSNR2 (413) 585-5181 UPLIFT CALCULATIONS PV 5 1/25/2016 (BBB)—SOL—CITY(765-2489) rw.$olarc!Y (E) COLLAR TIE (E) KNEE WALL S1 0 12'-3" (E) LBW B SIDE VIEW OF MP2 NTS MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED PORTRAIT 64" 20" -+ RAFTER 2x6 @ 16"OC ROOF AZI 271 PITCH 40 STORIES: 1 ARRAY AZI 271 PITCH 40 C.]. 2X8 @16"OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZED LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C — �y�H OF q ZEP FLASHING C (3) (3) INSERT FLASHING � N �G (E) COMP. SHINGLE (4) PLACE MOUNT. -' I L y (E) ROOF DECKING (2) Q INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) j(5) SEALING WASHER. ASS NAL tiNG�a STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH 01/26/2016 WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER S CONFIDENTIAL — THE INFORMATION HEREIN NUMBER: J B-0101874 00 PREMISE OWNER: DESCRIPTION: DESIGN: JOB \`�1�SolarCity CONTAINED SHALL NOT BE USED FOR THE BUUCK, MARILYN BUUCK RESIDENCE Rich Choza BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'���� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 260 N MAPLE ST 2.6 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION NTH 24 St. Martin Drive, Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (10) TRINA SOLAR # TSM-260PDO5.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV. DATE: T: (650)636-1028: (650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER' PAGE # SE3000A-USOOOSNR2 (413) 585-5181 STRUCTURAL VIEWS PV 4 1/25/2 1 1 (BBB)—sa.-arr(765-2489) .,rr,.galarcityaam PITCH: 40 ARRAY PITCH:40 O -� M132 AZIMUTH:271 ARRAY AZIMUTH: 271 MATERIAL: Comp Shingle STORY: 1 Story 1012> B � N LEGEND O (E) UTILITY METER & WARNING LABEL m� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS Front Of House OFS © AC DISCONNECT & WARNING LABELS o N a cO DC JUNCTION/COMBINER BOX & LABELS U ( L H 1 DISTRIBUTION PANEL & LABELS S NAl�� Lc 01/26/2016 LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Digitally signed by Nick Gordon STANDOFF LOCATIONS Date:2016.01.2609:05:17-08'00' CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE HEAT PRODUCING VENTS ARE RED F, INTERIOR EQUIPMENT IS DASHED L_"J SITE PLAN N Scale: 1/8" = 1' W E 0 1' 8' 16' S J B-0101874 00 PREMISE OIMIER. DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE BUUCK, MARILYN BUUCK RESIDENCE Rich Choza " ��SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 260 N MAPLE ST 2.6 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (10) TRINA SOLAR # TSM-260PD05.18 SHEET REV DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER: SOLAREDGE # SE3000A-USOOOSNR2 413 585-5181 SITE PLAN PV 3 1/25/2016 (688)—sa-CITY(765-248x) rr■rr.solarcity.com PROPERTY PLAN N Scale:i" = 20'-0' W E 0 20' 40' S CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B-01018 7 4 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT E USED RC THE BUUCK, MARILYN BUUCK RESIDENCE Rich Chozo `,`!}solarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MWNIING SYSTEM: �-NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 260 N MAPLE ST 2.6 KW PV ARRAY 'ii1. PART IZ OTHERS C OUTSIDE IN THE RECIPIENT'S FLORENCE, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES Moron Drive, Building 2. Unit 11 THE SALE AND USE OF THE RESPECTIVE (10) TRINA SOLAR # TSM-260PD05.18 24 St. Building SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV. DATE: Marlborough,MA 01752 PERMISSION OF SGLARCITY INC. /413 585-51 81 T. (650)636-1026 F: (650)636-1029 SOLAREDGE SE3000A—USOOOSNR2 \ � PROPERTY PLAN PV 2 1/25/2016 (888)—SOL—CITY(765-2489) www.solorcity.com ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTER11ED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CITY OF NORTHAMPTON EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH LL TERMINALS OF THE DISCONNECTING (E) EXISTING E A BUILDING DEPARTMENT - EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. These plans have been reviewed GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY And approved. HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. pp ll I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL _ Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER Date kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). nature MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT WATT PV1 COVER SHEET W W WATT 3R, RAINTIGHT PV2 PROPERTY PLAN PV3 SITE PLAN PV4 STRUCTURAL VIEWS PV5 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV6 THREE LINE DIAGRAM Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. • 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: * • REV BY DATE COMMENTS AHJ: Northampton "` REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) J B-010187 4 0 0 PRASE OVINER: DESCRIPTION. CONTAINED L — THE INFORMATION HEREIN JOB NUMBER: BUUCK MARILYN BUUCK RESIDENCE Rich Chozo WgsolarCity. CONTAINED SHALL NOT BE USED FOR THE > �•��' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 260 N MAPLE ST 2.6 KW PV ARRAY NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS FLORENCE,FLORENCE, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive,Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (10) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME: SHEET: REV DATE: M38-1028 MA 50) SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650) .Warci y. PERMISSION of soLARaTY INC. SOLAREDGE SE3000A-USOOOSNR2 (413) 585-5181 COVER SHEET PV 1 1/25/2016 (BBB)-saL-CITY(ass-24e9) �..8alar�itr.aan, . r 1 CALCULATION OF DESIGN WIND LOADS - MP2 Mounting Pane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware Comp Mount Type C Roof Slope 400 Rafter Spacing 16"O.C. Framing Type/Direction Y-Y Rafters Puriin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 Psf Wind Pressure Ext. Pressure Coefficient U GC u -0.95 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GCp(Downl 0.88 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure U -14.2 psf Wind Pressure Down 13.1 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -223 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 44.6% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 64" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 29 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -371 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacty DCR 74.2% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP2 Member Properties Summary MP2 Horizontal Member Spans Rafter Pro Overhang 0.82 ft Actual W 1.50" Roof System P sties San 1 12.29 ft Actual'D 5.50 Number of Spans w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof San 3 A 8.25 in.^2 Re-Roof No Span 4 S. 7.56 in A3 Plywood Sheathing No San 5 I 20.80 in.^4 Board Sheathing Solid-Sheathing Total Rake Span 17.11 ft TL Defl'n Limit 120 Vaulted Celling Yes PV 1 Start 1.50 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 12.16 ft Wood Grade #2 Ratter Slope 400 PV 2 Start fb 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing PV 3 Start E 1400000 psi Bot Lat Bracing Full PV 3 End Em;n 510000 psi Member Loading mary Roof Pitch 10/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 14.0 psf x 1.31 18.3 psf 18.3 psf PV Dead Load PV-DL 3.0 psf x 1.31 3.9 psf Roof Live Load RLL 20.0 psf x 0.70 14.0 psf Live/Snow Load LL-SL1,2 40.0 psf x 0.65 1 x 0.35 1 26.0 psf 14.0 psf Total Load(Governing LC TL 1 1 44.3 psf 36.2 psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)pg; Ce=0.9,Ct=1.1,I5=1.0 Member Design Summa (per NDS Governing Load Comb I CD I CL + CL - CF Cr D+ S 1.15 1.00 1 1.00 1 1.3 1.15 Member Anal sis Results Summary Governing Analysis Pre-PV Demand Post-PV Demand Net Impact Result Gravity Loading Check 1756 psi- 1424 psi 0.81 Pass } Version#53.6-TBD y HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Sp ecifications Hardware X-X Spacing X-X Cantilever Y-Y Sp cing Y-Y Cantilever Configuration Uplift DCR MP2 64" 24" 39" NA Staggered 44.6% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Sp cing Y-Y Cantilever Configuration Uplift DCR MP2 64" 20" 65" NA Staggered 74.2% Structure Mounting Plane Framing Qualification Results Type Spacing Pitc6 Member Evaluation Results MP2 Finished Attic @ 16 in.O.C. 400 Member Impact Check OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 3055(;learview Way Sail Mateo. GA 9440' T(650)638-1028 (888)S;01--CITY F(6)O)638-1029 solarcity.corn 46 Version#53.6-TBD SolarCity. January 26,2016 K OF RE: CERTIFICATION LETTER N G Project/Job# 0101874 c Project Address: Buuck Residence " 1 L 260 N Maple St 1 Q Florence, MA 01062 AHJ Northampton `s NAL EN SC Office Springfield 01/26/2016 Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 90 mph, Exposure Category C - Ground Snow Load =40 psf - MP2: Roof DL= 14 psf, Roof LL/SL= 26 psf(Non-PV Areas), Roof LL/SL= 14 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22424 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluationI certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. Digitally signed by Nick Gordon Date:2016.01.26 09:05:02-08'00' 3055 Clearview Way San Mateo, CA 94402 T(650)638-1028 (888)SOS-CITY F(650)638-1029 solarcity.com DocuSign Envelope ID:5D411 DB8-5F79-4359-A816-1701 D3FCBC38 + 23. NOTICE OF RIGHT TO CANCEL. 1 have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Marilyn Buuck EXPLANATION OF THIS RIGHT. �DDoocuSigned by: 24. ADDITIONAL RIGHTS TO CANCEL. Signature: IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: 1/22/2016 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after 1/22/2016. Customer's Name: If you don't sign this PPA and return it to us on or prior to 30 days after 1/22/2016,SolarCity reserves the right to Signature: reject this PPA unless you agree to our then current pricing. Date: Power Purchase Agreement SolarCity approved Signature: Lyndon Rive, CEO Date: 1/22/2016 �ct,e .jr_hase Agreement, 9A 0,N ewber 1 2015 7.'i?Cer47 DocuSign Envelope ID:5D411 DB8-5F79-4359-A816-1701 D3FCBC38 SolarCity I PPA Customer Name and Address Installation Location Date Marilyn Buuck 260 N Maple St 1/22/2016 260 N Maple St Florence,MA 01062 Florence,MA 01062 Mere are the key terms of your Poorer Purchase Agreement AL 1110111111111111k gloom Amml. ,go& m maw ME OR %_ 0 N& ftp %J 2uyt System installation cost Electricity rate gj kWh Agreement Tgjm A � �� initial here _ Initial here_,,,', DS The SolarCity Promise �&. •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement ............................. initial here •We warrant all of our roofing work. DS •We restore your roof at the end of the Agreement. •We warrant,insure, maintain and repair the System. ..... ......... .-........... . . ... . .................. -. Initial here •We fix or pay for any damage we may cause to your property. •We provide 24/7 web--enabled monitoring at no additional cost. •The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 1/22/2016.` Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing =� Term: •At certain times,as specified in •SolarCity will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 •You can upgrade to a new System with •These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est.amount due at building inspection contract. not beyond that term. •You may purchase the System from Est.first year production SolarCity for its fair market value as 2,330 kWh specified in the Agreement. •You may renew this Agreement for up to ten(10)years in two(2)five(5)year increments. 3055 Clearview Way, San Mateo, CA 94402 1 888.7651489 1 solarcity.corn 1510642 Power Purchase Agreement,version 9.1.0,November 11,2015 SAPC/SEFA Compliant Contractors License MA HIC 168572/EL-1136MR Document generated on 1/22/2016 �Ijff] Copyright 2008-2015 SolarCity Corporation,All Rights Reserved Aia.. l�]® CERTIFICATE OF LIABILITY INSURANCE DATE(12015 "'"' oan7na15 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,',EXTEND OR ALTER THE COVERAGE AFFORDED 13Y THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the polley((es)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such andorsement(s). PRODUCER CONTACT MARSH RISK& INSURANCE SERVICES _NA111FE: . ._ PHONE _.... .........,.................. FAX..,....... ......_..........-..._........ ..... 345 CALIFORNIA STREET,SUITE 1300 (AtG-Ka xtlL ............_.............. .............. ......... ...... 1a_rc_ Mo1•._......._.- ......... ._............... CALIFORNIA LICENSE NO.0437153 E-MAtt SAN FRANCISCO,CA 94104 -ARBRIESS.................... ._... .... Attn:Shannon Scott 415743.8334 tNSttRE�B)AFFORmNG COVERAGE NA(C tT — — .. ._ 998301-STNA-GAWUE-15-16 _._._.__ INSURER A:Zurlch American Insurance Company 16535 INSURED ... .-..-...._ INSURER 13!NIA. SDIarCltyCorporation 3055 Clearview Way INSURER C:NIA ._ __ N/A San Mateo,CA 94402 INSURER p;American Zurich insurance Company 40142 INSURER 9: .. INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002793836.08 REVISION NUMBER-.4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE 13FEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT NTH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDC SUBR .. .. ............._.—.__—.....—. POLICY EFF POLICY E%P _. .........__..__.... .._ ... ._ ...._.._. LT TYPEOFINSURANCE POLICY NUMBERM/OD/YYYY�MMJDDIYYYY�—.- - – LIMITS A I X :COMMERCtAL GENERAL LIABILITY !GLO0182016-00 09!0112015 !09,01121116 (....-. ..-,.- r� EACH OCCURRENCE $ 3,000,000 DAMAGE TO RENTED CLAIMS-MADE I.X OCCUR i - PR�MISFS-(E.a occu renceJ $ .. .. 3.0w.000 X SIR:$250,000 MEp EXP(Any.one person! S 5,000 PERSONAL&ADV INJURY S 3,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE 5 6,000,000 X POLICY PRO- LOC 'PRODUCTS S 6,000,000 L .. JECT t.. _( . -. -.....- f....... .... ... .... ........... OTHER: ! f S A AUTOMOBILE LIABILITY BAP0182017.00 0910112015 09/01/2016 COMBINED SINGLE LIMIT S 5,000,000 X .ANY AUTO j BODILY INJURY(Per person) S X ;ALL OWNED X AUTOSULED BODILY INJURY(Per accident) $ ............ ....... NON-OWNED i PROPERTY DAMAGE S X HIRED AVTOS .X AUTOS i 1Per ac[A.denl................... COMP/COLL DED: S ss,aaa UMBRELLA LIAR ( I f OCCUR EACH OCCURRENCE S E%CESSLIAB _CLAIMS-MADEi AGGREGATE $ DED I RETENTI N S Is ID WORKERS COMPENSATION WC0182014.00(ACS) 09101/2015 09MI12016 X f PER OTH-AND EMPLOYERSL1AaILrTY I�� .-..i.STATUTE..j, ER . ..ANY PROPRIETORIPARTNERIEXECUTIVE YIN NIA 'WC0182015.00(MA) 09101/2015 09/01/2016 t E.L.EACH ACCIDENF i 5 1,000,000 OFFICERfM£M9ER EXCLUDED? p--. ......... . .. .....................•.... . .. ..-_..... (Mandatory In NH) VC DEDUCTIBLE:$500,000 E.L.DISEASE-EA EMPLOYE _S 1,000,000 If es.descnhe under f!. . I DESCRIPTION OF OPERATIONS belaN ! f E.L.DISEASE•POLICY LIMIT $ 1,000,000 f � 1 DESCRIPTION OF OPERATIONS 1 LOCATIONS I VEHICLES(ACORD 104,Additional Remarks Schedule,may tic attached ff mare space Is requiredl Evidence of insurance'. CERTIFICATE HOLDER CANCELLATION SoiarCily Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Cieamew Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 99402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Charles Marmolejo 0 1988-2814 ACORD CORPORATION. All rights reserved. ACORD 25(20141011 The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts �A : Department of IndustrialAccidents Office of Investigations , , _ # I Congress Street,Su to 100 Boston,AIA 02114-2017 Workers'Compensation Insurance Affidavit:Builders/Con tractors lElectricianalplumbelr's AnDlicant Information Please Print Le ibl Name(BusineWOrganizationlindividual): SOLARCITY CORP Address:3055 Ci_EARVIEW WAY City/State/Zip:SAN MATEO, CA 94442 Pltorte##:888-765-2489 Are you an employer?Check the appropriate box: Type of project(required): LN I am a employer with 5000 4. C] I am a general contractor and i etuployces(fall and/or part-time).* have hired the sub-contractors New t onstrttctian 2.[1 1 am a sole proprietor or partner- listed on the attached sheet_ 7. [ Remodeling ship and have no employees These sub-contractors have g Q Demolition working for me in any capacity, employees and have workers' [No workers' comp.insurance camp. insurance.= g ❑Building addition � We are a corporation required.] 5. oration and its 10.0 Electrical repairs or additions 3.Q 1 arts a homeowner doing all work officers have exercised their l 1.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.C]Roof repairs insurance required.]i c. 152,§1(4),and we have no SOLAR 1 PV employees. [No workers' 13.ff Other comp. insurance required.] •Any applicant that olimlot box#t most also tilt Dirt the sCCiinn beloly showing their workers'compensation policy information. f itomrowacts who submit ihis affidavit indicating they are doing all work and then hire outside contnotors must submit a new affidavit indicating such. tContractors that chcckthis box must attached on additional sheet showing the name or the sub-contractors and state whether or not those entities have employees. irthe sub-contractors have empioyocs,fhny must provide their work--crs'camp.policy number, I min an emptoyer Eleat is providing workers'coutpensatlou Imurancefor my enrployeay. Below rs the palicv aril Job site Information. Insurance Company Name: Zurich American Insurance Company Policy ft or Self--ins. Lic. M WCO182014-00_ Expiration mate:__ 09/01/2010 Job Site Address: 1 r' �,e city/State/zip: ^ �O11r_�._�l C r Attach a copy of the workers'compensati n policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL e. 152 can lead to the imposition of criminal penalties of a fine up to S1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby eer!!fy uuticr lkelxrlrrs rear!penalties of pertemir iltal Ose hirarmation provided above Is true turd correct. i � Sia�t ature:_ -- '• t:,�,...., .., I7ut r Phone t/� Off clal use only. Do not write in Ibis area,to be completed by city or tower official. City or Town: Pertnit/License# Issuing Authority(circle one): 1.13oaird of Health 2.Building Department 3.City/Town Clerk 4, Electrical inspector S.Plumbing Inspector 6.0ther Contact Person: Phone M SECTION 8-CONSTRUCTION SERVICES , 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Address Expiration Date 978-875-1698 Signature Telephone 8.Realetered Home Imorovement Contractor: Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2017 Address Expiration Date Telephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Dome Owner ;Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the buildine permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding[ ] Other Brief Description of Proposed � Work: Install solar electric panels to roof of existing home,to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roil -Sheet ea.If,New ho I use addition n t o-existina hous Ina, CoMpletathe'following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, yr la' vl I q n- r )J!/I_, � as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 01/27/2016 Signature of Owner Date I, SOLARCITY CORPNICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORPNICTORIA JUNCK Print Name 01/27/2016 Signature ord rWre—r/Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Requj ed by Zoning This lumn to be filled in by Buil ing Department Lot Size Frontage I Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. CI of Northamptonf P \1 9 s � �4 But ing Department C,� It s 2 Main Street oom 100 A�lllil JP� a ton, MA 01060 0 ofd l' 0 -1240 Fax 413-587-1272 � � I " A TION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 260 N Maple St Map Lot Unit Zone Overlay District Elm St.District CS District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Marilyn Buuck 260 N Maple St Florence,MA 01062 Name(Print) Current Mailing Address: 413-585-5181 Telephone Signature 2.2 Authorized A-gent: SolarCity CorpNictoria Junck 604 Silver St Agawam MA 01001 Name(Print) Current Mailing Address: 978-215-2367 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building ��n 12 (a)Building Permit Fee , 2. Electrical 5006 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) 660 Check Number `J This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2016-0953 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (978)215-2369 Q PROPERTY LOCATION 260 NORTH MAPLE ST MAP 12C PARCEL 049 001 ZONE RIO 00)/URA(100)/WSP(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid WOU Building Permit Filled out Fee Paid Typeof Construction: INSTALL ROOF MOUNTED 2.6KW SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management De olition Delay A;2 71d Sig re of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 260 NORTH MAPLE ST BP-2016-0953 G1S#: COMMONWEALTH OF MASSACHUSETTS MapBlock: 12C-049 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-0953 Project 9 JS-2016-001615 Est. Cost: $7000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq. ft.): 9801.00 Owner: BUUCK MARILYN J Zoning: R[(100)/URA(100)/WSP 100)/ Applicant: SOLARCITY CORP AT. 260 NORTH MAPLE ST Applicant Address: Phone: Insurance: 604 SILVER ST (978)215-2369 O Workers Compensation AGAWAMMA01001 ISSUED ON:112912016 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 2.6KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 1/29/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner