16D-004 (6) Air Leakage Property Organization HERS 206 N. Main St Center for EcoTechnology Confirmed Florence, MA 01062 413-586-7350 8/17/15 John Saveson Rating No:P15326 Weather:Northampton, MA Rater ID:1911963 206 N. Main St, Lot 2 Builder P15326 206 N. Main St Florence Joslad It Associates, P.C. final.blg Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.13 0.09 ACH 50 Pascals 2.10 2.10 CFM 25 Pascals 694 694 CFM 50 Pascals 1089 1089 Eff. Leakage Area (sq.in) 59.8 59.8 Specific Leakage Area 0.00016 0.00016 ELA/100 sf shell (sq.in) 0.84 0.84 Duct Leakage Leakage to Outside Units heating B cooling CFM @ 25 Pascals 38 CFM25 / CFMfan 0.0274 CFM25 / CFA 0.0146 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 60 Eff. Leakage Area (sq.in) 3.27 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.1351 Ventilation Mechanical None ASHRAE Sensible Recovery Eff. (%) 0.0 62.2-2010 Total Recovery Eff. (%) 0.0 Rate (cfm) 0 56 Hours/Day 24.0 24.0 Fan Watts 0.0 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - Ventilation Requirements The ASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the'whole-building requirement under that version of the standard. Both values incorporate any appropriate'infiltration credit'. Intermittent mechanical ventilation may be used if the flow rate is adjusted accordingly. For example, the runtime can be reduced to 12 hours per day using a doubled flow rate, as long as the system provides ventilation at least once every 3 hours. For more detail, refer to the appropriate standard. REM/Rate- Residential Energy Analysis and Rating Software 04.6.1 This information does not constitute any warranty of energy cost or savings. ©1985-2015 Noresco, Boulder, Colorado. Home Energy Rating certificate Property HERS Rating Type: Confirmed Certified Energy Rater: John Saveson 206 N. Main St Rating Date: 8/17/15 Rating Number: P15326 Florence, MA 01062 Registry ID: 580870128 Estimated Annual Energy Cost Use MMBtu Cost Percent HERS Index: 63 Heating 43.2 $2695 56% General Information Cooling 6.5 $146 3% Conditioned Area 2598 sq. ft. House Type Single-family detached Hot Water 4.6 $477 10% Conditioned Volume 31167 cubic ft. Foundation Conditioned basement Lights/Appliances 25.1 $1529 32% Bedrooms 3 Photovoltaics -0.0 $-0 -0% Service Charges $0 0% Mechanical Systems Features Total 79.4 $4847 100% Heating: Fuel-fired air distribution, Propane, 95.0 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Criteria Water Heating: Instant water heater, Propane, 0.94 EF, 0.0 Gal. This home meets or exceeds the minimum criteria for the following: Duct Leakage to Outside 38.00 CFM25. Ventilation System None Programmable Thermostat Heat=Yes; Cool=Yes Building Shell Features Ceiling Flat R-55.5 Slab R-0.0 Edge, R-0.0 Under Sealed Attic NA Exposed Floor R-30.0 Vaulted Ceiling NA Window Type U-Value: 0.290, SHGC: 0.250 Above Grade Walls R-21.0 Infiltration Rate Htg: 1089 Clg: 1089 CFM50 Foundation Walls R-17.6 Method Blower door test TITLE Company Lights and Appliance Features Address Percent Interior Lighting 72.90 Range/Oven Fuel Propane City, State, Zip Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric Phone# Refrigerator(kWh/yr) 722 Clothes Dryer EF 3.01 Fax# Dishwasher(kWh/yr) 265 Ceiling Fan (cfm/Watt) 0.00 REM/Rate- Residential Energy Analysis and Rating Software v14.6.1 This information does not constitute any warranty of energy cost or savings. O 1985-2015 Noresco, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. R Light Commercial HVAC Loads Elite Software Development,Inc.l New Home 206 N.Main St, Northampton Page 6- -System 1 Room Load Summary Itg'9 , 'Run Min , Act l xW �it�9 Duct Duct Sens La CIg- Sys , ,; . SFF . .... Btuh . �� >�,GFIII� She Vel,� Btuh `Btuh :CFM CFM ---Zone 1--- -- —. . . —�— 1 Family Room 414 6,396 84 1-7 521 3,036 0 139 139 2 Dining Room 208 2,943 39 1-6 330 1,414 0 65 65 3 Kitchen 330 5,201 68 2-7 492 5,728 800 263 263 4 Mud Hall/ Half 145 2,625 34 1-6 203 870 0 40 40 Bath 5 Master Bedroom 281 3,240 42 1-6 451 1,928 0 88 88 6 Front Bedroom 202 3,001 39 1-6 395 1,689 0 78 78 !. 7 Guest Bathroom 98 829 11 1-6 107 456 0 21 21 8 Rear Bedroom 162 2,079 27 1-6 254 1,086 0 50 50 9 Master Bathroom 198 2,323 30 1-6 275 1,175 0 54 54 10 Master Bedroom 171 1,349 18 1-6 192 820 0 38 38 Closet/Storage Ventilation 11,438 2,288 2,104 Duct Latent 756 System 1 total 2,209 41,425 393 20,489 3,660 835 835 System 1 Main Trunk Size: 16x10 in. Velocity: 752 ft./min Loss per 100 ft.: 0.097 in wg RO = g I u s tzleth1E, Sensible Latent Total .. .,..., s,f,„ cpii <?Bt4ih _.L .Btuh Net Required: 2.01 85%/ 15% 20,489 3,660 24,149 Recommended: 2.28 75%/25% 20,489 6,830 27,319 ��(ll KT1hQata�` ,A„t .t _ Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: Indoor Model: Brand: Efficiency: 0 AFUE 0 SEER Sound: Capacity: 0 Btuh 0 Btuh Sensible Capacity: n/a 0 Btuh Latent Capacity: n/a 0 Btuh i i I I I i i � II C:\Program Files (x86)\Elite\Rhvacw\Projects\-U NTT LO.rhv Tuesday, June 30, 2015, 10:45 AM 'Rhvac-.Residential&Light Commercial HVAC Loads Elite Software Development,Inc.l New Home 206 N Main St,Northampton --- Page,5 System 1 Sum mary_Loads a. C � �� Sen Lat tal Area Sen -- To 9e n n r4.i R4 . � .. k`. i Quan Loss Gain: Gain,,_ Gain l 1 D-hw-o: Glazing-Double pane, operable window, heat- 88 3,510 0 3,375 3,375 absorbing, wood frame, u-value 0.57, SHGC 0.44 1 D-hw-d: Glazing-Double pane, sliding glass door, heat- 139 5,546 0 5,624 5,624 absorbing, wood frame, u-value 0.57, SHGC 0.44 11 J: Door-Metal - Fiberglass Core 19.5 819 0 293 293 11 N: Door-Metal - Polystyrene Core 19.5 478 0 171 171 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 2022.4 9,627 0 2,254 2,254 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1110.5 2,021 0 1,414 1,414 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 19B-2sp: Floor-Over enclosed unconditioned crawl 1097.2 2,341 0 469 469 space, R-4 insulation on exposed walls, sealed crawl space, passive, R-2 or R-3 board Subtotals for structure: 24,342 0 13,600 13,600 People: 4 800 920 1,720 Equipment: 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 5,645 756 1,338 2,094 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 150, Summer CFM: 150 11,438 2,104 2,288 4,391 AED Excursion: 0 0 1,143 1,143 System 1 Load Totals: 41,425 3,660 20,489 24,149 "Ch I _ Supply CFM: 835 CFM Per Square ft.. 0.378 Square ft. of Room Area: 2,209 Square ft. Per Ton: 970 Volume (ft') of Cond. Space: 18,759 to ''�� °;,`' � .tom i� a' %ra .r. k� \$-'r' �. �,�. . . Total Heating Required Including Ventilation Air: 41,425 Btuh 41.425 MBH Total Sensible Gain: 20,489 Btuh 85 % Total Latent Gain: 3,660 Btuh 15 % Total Cooling Required Including Ventilation Air: 24,149 Btuh 2.01 Tons (Based On Sensible + Latent) 2.28 Tons (Based On 75% Sensible Capacity) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. � l i I I � � I C:\Program Files(x86)\Elite\Rhvacw\Projects\-UNTTLO.rhv Tuesday, June 30, 2015, 10:45 AM rRhvac Resitl_ential&Light Commercial HVAC Loads Elite Software Development,Inc. New Home 206 N.Main St, Northampton -- -- ---- ---- ----- 9 ---- ---. --- - Pa a 4_ Total Building-Summary-Loads t We "s r Area Sert -� Lat 1i Sen Total M tllaan Loss Gain G_am, , Gain §..._� . �, �; _ _ 1 D-hw o: Glazing-Double pane, operable window, heat- 88 3,510 0 y3,375 _3,375 absorbing, wood frame, u-value 0.57, SHGC 0.44 1 D-hw-d: Glazing-Double pane, sliding glass door, heat- 139 5,546 0 5,624 5,624 absorbing, wood frame, u-value 0.57, SHGC 0.44 11J: Door-Metal - Fiberglass Core 19.5 819 0 293 293 11 N: Door-Metal - Polystyrene Core 19.5 478 0 171 171 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 2022.4 9,627 0 2,254 2,254 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 1110.5 2,021 0 1,414 1,414 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 19B-2sp: Floor-Over enclosed unconditioned crawl 1097.2 2,341 0 469 469 space, R-4 insulation on exposed walls, sealed crawl space, passive, R-2 or R-3 board Subtotals for structure: 24,342 0 13,600 13,600 !, People: 4 800 920 1,720 Equipment: 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 5,645 756 1,338 2,094 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 150, Summer CFM: 150 11,438 2,104 2,288 4,391 AED Excursion: 0 0 1,143 1,143 Total Building Load Totals: 41,425 3,660 20,489 24,149 Z� .,. ax7• 't aarM62L A Total Building Supply CFM: 835 CFM Per Square ft.: 0.378 Square ft. of Room Area: 2,209 Square ft. Per Ton: 970 Volume (fP,of Cond. Space: 18,759 Way"- Total Heating Required Including Ventilation Air. 41,425 Btuh 41.425 M Total Sensible Gain: 20,489 Btuh 85 % Total Latent Gain: 3,660 Btuh 15 % Total Cooling Required Including Ventilation Air: 24,149 Btuh 2.01 Tons (Based On Sensible+ Latent) 2.28 Tons (Based On 75% Sensible Capacity) ,. Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I I I i C:\Program Files (x86)\Elite\Rhvacw\Projects\-UNTTLO.rhv Tuesday, June 30, 2015, 10:45 AM (Rhvac Residential'&Light Commercial HVAC Loads Elite Software Development,Inc. New Home 206 N.Main St, Northampton Page 3 Load Preview Report : Net Rec, ft.21 I Sen Lat Net Sen- Min, Mini Sysi Sys; Sys; Duct° i i f Htg! Clg' Htg a Clg( Act# Scope TO /Toni Areal Gafnj Gains Gain? Loss CFMf CFM CFMj CFMI CFM; Size Build.. in g 2.01 2.28 970 2,209 20,489 3,660 24,149 41,425 393 835 393 835 835 System 1 2.01 228 970 2,209 20,489 3,660 24,149 41,425 393 835 393 835 835 16x10 Ventilation 2,288 2,104 4,391 11,438 1 Duct Latent 756 756 ' Zone 1 2,209 18,201 800 19,001 29,987 393 835 393 835 835 16x10 1-Family Room 414 3,036 0 3,036 6,396 84 139 84 139 139 1-7 2-Dining Room 208 1,414 0 1,414 2,943 39 65 39 65 65 1-6 3-Kitchen 330 5,728 800 6,528 5201 68 263 68 263 263 2-7 4-MudHaN Half Bath 145 870 0 870 2,625 34 40 34 40 40 1-6 5-Master Bedroom 281 1,928 0 1,928 3240 42 88 42 88 88 1-6 6-Front Bedroom 202 1,689 0 1,689 3,001 39 78 39 78 78 1-61 7-Guest Bathroom 98 456 0 456 829 11 21 11 21 21 1-61 8-Rear Bedroom 162 1,086 0 1,086 2,079 27 50 27 50 50 1-61 9-Master Bathroom 198 1,175 0 1,175 2,323 30 54 30 54 54 1-61 10-Master Bedroom Closet/Storage 171 820 0 820 1,349 18 38 18 38 38 1-6 i i I l i VIII C:\Program Files (x86)\Elite\Rhvacw\Projects\-UNTTLO.rhv Tuesday, June 30, 2015, 10:45 AM Rhvac Reside- ntial;&Light Commercial HVAC Loads Elite Software Development,Inc. - -ALL ., . New Home 206 N.Main St, Northampton -- - g �Pmject Report Project Title: New Home 206 N. Main St, Northampton Designed By: B.T. Project Date: Tuesday, June 30, 2015 Client Address: 206 N. Main St Client City: Northampton Ma Company Name: Brian Tatro Electrician Company Representative: Brian Tatro Company City: Springfield Ma Company Phone: 413-782-2290 Reference City: Westover AFB,%Massachusetts Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 270 ft. Altitude Factor: 0.990 I Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 0 -0.65 80% n/a 70 n/a Summer: 89 71 42% 50% 75 21 dr,u ,.xi¥ ' . �a z:;P b x.a v r;a, ts, •w :_ I Total Building Supply CFM: 835 CFM Per Square ft.: 0.378 Square ft. of Room Area: 2,209 Square ft. Per Ton: 970 Volume (ft') of Cond. Space: 18,759 Total Heating Required Including Ventilation Air: 41,425 Btuh 41.425 MBH Total Sensible Gain: 20,489 Btuh 85 % Total Latent Gain: 3,660 Btuh 15 % Total Cooling Required Including Ventilation Air: 24,149 Btuh 2.01 Tons (Based On Sensible + Latent) 2.28 Tons (Based On 75% Sensible Capacity) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. I 'I C:\Program Files (x86)\Elite\Rhvacw\Projects\—UNTTLO.rhv Tuesday, June 30, 2015, 10:45 AM EFL z 9 NC,Plu rtham tng 6 A MA 01 New Home 206 N. Main St, o mpton HVAC Load Calculations for j 206 N. Main St Northampton Ma I � hq L u t 7 I i j I I Prepared By: Brian Tatro Brian Tatro Electrician Springfield Ma 413-782-2290 Tuesday, June 30, 2015 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.