Loading...
22D-110 =@@ Single Phase Inverters for North America so I a r SE3000AUSiSE3800A-US/SE5000A-US/SE3000A-US s o I a r SE760OA-US/SE1000i}A-US%SE11400A-US SE3000A-US SE39GOA-US'': SE5000A-US SE6000A-US'..SE7600A-USI SE10000A-US: SE1140OA-US OUTPUT SolarEdge Single Phase Inverters . 10900 @24DV i.4D0 Nominal AC Power Output 3000 3800 5000 o00L' 7600 9980 @ 208V - A 5400 @ 208V 10800 @ 208V For North America Max.AC Power Output 3300 4150 5450 @240V 600C 8350 10950 @240V 12000 VA AC Output Voltage Min.-Nom.-Max�'i : _ ✓ ✓ SE300OA-US/ SE380OA-US SE500OA-US tSE600OA-US! 183 208 229 Vac AC Output Voltage Min.-Nom.-Max�'I � J J ✓ ✓ '' ✓ J J ' SE760OA-US i SE10000A-US SE1140OA-US 211-240-264 Vac AC Frequency Min.-Nom:Max."l 59.3-60-60.5(with HI country setting 57-60-60.5) Hz 24 @ 208V 48 @ 208V ✓ r. s Max-Continuous Output Current 2.5 16 25 32 47.5 A ! N' .� � ... GI DI Threshold g y 21 @ 240V 42 @ 240V - { Utility Monitoring,Islandin Protection,County Configurable 1 A f r € u gurable Thresholds Yes Yes INPUT - - - - - - - _ _ Maximum DC Power(SrC) 4050 5100 6750 8100 10250 13500 15350 W Transformer-less,Ungrounded Yes w � � .����� Max.Input Voltage 500 Vdc N om.DC Input Vol tage - 5 @ .08 V 35 40V Vdc 16.5 @ 208V 33 @ 208V Max.Input Current"' 9.S 13 18 23 34,S Adc 4 1 5.5C 7 40 V 30.5 C 2 40V Max.Input Short Circuit Current 45 Adc r Reverse-Polarity Protection Yes - rst Ground Fault Isolation Detection 600kn Sensitivity ;,,. f' Maximum Inverter Efficiency 97 7 98.2 98.3 98 3 98 98 98 r ` 975 @ 208V 97 @ 208V CEC Weighted Efficiency 97 S 98 97.5 97.5 97.5 % ;"' �s ' � _ 98 @ 240V 97.5 @ 240V Nighttime Power Consumpton <2.5 <4 W Supported Communication Interfaces " RS485,RS232,Ethernet,ZigBee(optional) Revenue Grade Data ANSI(.12.1 Optional '- Rapid Shutdown-NEC 2014 690 12 Functionality enabled when SolarEdge rapid shutdown kit is installedi4l STAN _ _. . _.._ . . _. DARD COMPLIANCE - - — - — — '� Safety UL-1141,UL1699B,UI 1998,CSA 22.2 Grid Connection Standards IEEE1547 - 4 r Emissions FCC partly class B ........... ACout co�aYitPECIPICATIONS - �s INSTALLATION 5 se &�. ...._... ._.... __._ -__. ____. _._.. .......... ......_... ._...... ........ .... E p size/AWG range 3/4'rninirnum/166AWG 3/4"minimum/83AWG DC input conduit size/#of strings/ 3/4"minimum/1 2 strings/ t -2 strings AWG range 3/4"minimum/1 /16-6 AWG 14-6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 1.0.5/ in/ 30.5 x 12.5 x 7.2/775 x 315 x 184 (FixWxD) 775 x 315 x 260 mm Weight with Safety Switch 51.2/23.2 54.7/24.7 88,4/401 lb/kg Natural convection _ Cooling Natural Convection and internal '.. Fans(user replaceable) - �' fan(user lhcbe chiSc r s i 1 � replaceable) ,. Noise <25 <50 dBA fr tegrated arc fault Prot:etion{rYi a 1,)for`�i O D13 69011 C4n'tpliance Min.-Max.Operating Temperature -13 to+140/-25 to+60(-40 to+60 version available")) -F/'C Superior efficiency(9 ) Range Small,',Iightweight and easy to instAll Do provided b racket "'For oetction Rating semn lease contact soia,Ed - - NFMA 3R rg ona gs p ge suppo t. q �A high t uncle ay be used;the-nverter w II m[[-p[ rent m the values stated. Bulit'Inmodule'ievelmunitioning 131Revenueg d e rter P/N.SExxx,AUS000NNR2(for 760OW,nverte,SE7600AUS002NNR2). I. Ethernet �4:Rap d shutdown kit P/N:SE10M RSD-Sl. Internet connection through Ethernet or wireless �s�40 version P/N.SExxxxA-USOOONNU4(for 7600W inverter:SE76MA-US002NNU4). Outdoor and Indoor installation Fixed voltage inverter,DC/AC conversion only — Pre-assembled Safety Switch for faster installation Optional—revenue grade data,ANSI 0121 r c c RoHS 1 1:.A :-cF 1 A NY_-:_,._t-E...,f,_, t..�r>'s, 11 NA S _!=,.IH IF N It 1_ -5.:, EL wwW,solaredge.0-ci ,1�)wugrNgllpint i THE ViI amount MODULE TSM-PDO5.18 Mono Multi Solutions ..... ..�..�..... _ DIMENSIONS OF PV MODULE ELECTRICAL DATA i'STC unit,mm Peak Power Watts-PMAx(Wp) 250 255 260 265 941 Power Output Tolerance-P-(%) 0-+3 Maximum Power Voltage-VMe(V) 30.3 30.5 30.6 30.8 THE t -o irinalw*nloun I nNCrwN o eoa Maximum PowerCurrent-I.EP(A) 8,27 8.37 8.50 8.61 ruMEnArE I a Open Circuit Voltage-Voc(V) 38.0 38-1 38.2 38.3 I w:°r iuNC HN�e Short Circuit Cutrent-13c(A) '. 8,79 8,88 9.00 410 0 Module Efficiency rlm 15.3 15.6 15-9 16.2 MODULE STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AMI.5 according to EN 60904-3, typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. o ' ELECTRICAL DATA `f�C3C' Maximum Poi 186 190 793 197 ELL Maximum Flower Voltage-VMr[V) 289 28.1 28.3 28.4 MULT'CRY£TALLINE MODULE „.,„,, _ Maximum Power Current-I [A) 6.65 674 6.84 6.93 'siV .i tit a 604.3 GPOVNpNG HUtE PD05.18 A ? Open Circuit Voltage(V)Voc(V) 352 35.3 35.4 35 5 WITH TRINAMOUNT FRAME "��'N"°`E - Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 NOCT:Irradiance at 800 W/m`,Ambient Temperature 20°C,wind Speed 1 m/s. 812-�------180 Back View ME%FAN34AS DATA POWER OUTPUT RANGE Solarcells Multicrystalline 156 x 156 mm(6 inches) Fast and simple to install through crop in mounting solution Cell orientation 60 aelrs[6x lD) Module dimensions 1650-992-40 mm(64.95-39.05-1.57 inches) Weight 19.6 kg(43:12lbs) -- ____ _....._ ___... _.__.. ._._. ____ __-. i //�� Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EFFICIENCY Bdcksheet White A-A Frame Black Anodized Aluminium Alloy € od aesthetics for residential applications J-Box ':IP 65 or IP'67 rated Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 1200 mm(47.2 inches) I-V CUiVES LOP FV MODULE(260-W) POSITIVE POWER TOLERANCE t000 Connector fidAmphenol sao 10-00Wr - Fire Type UL 1703 Type 2 for Solar City Highly reliable dale to stringent quality control aoo a l F Too - --� - o e g `� _.�,t.;- J .-' s F Y �`'.�� -3ti:1 -. . C _I _ . 600W _ k�rF_RA°Et'r?_ tAi`_--'tYfiS gxiAl �hil2 €AFrGIvS r, r < d 400 Nominal Operating Cell Operational Temperature -40-+1 44°C(+2°C) Temperature(NOCT) Maximum System I000V DC(IEC) _ ___...._.._.._...__ __ ._....._...__ ......._._ _._.._. _._- ..___ - r zoowrm' 0.41%/°C Voltage II . Temperature GOefflclentofPm ` 1000VDC(ULJ r r. T € r: loo "" - 'Alt,_-"- -- Temperature Coefficient of Voc -0 32%/°C Max Series Fuse Rating 15A o b.c,I o,FI id-ev o p,$c 7 e,I Fr o00 -- Certified to withstand challenging environmental o ,o zo so 40 o Temperature Coefficient ofisc 0,05171=C OM I .; .rE,� conditions vaup.(v) ...CIF?I•- itt �T. .. 's'' � ...,... I -:,j s Jf!7 ._7,F,-j Ei AiARRANTy c•, - CERTIFICATION 10 year Product Workmanship warranty C I 7C T r `1st 25 year Linear Power Warranty (Please rare,to product waNanty for details) Q rS < f N LINEAR PERFORMANCE WARRANTY ": niiiiiiiii PACKAGING CONFIGURATION U-28WFFE .....__.._. 1 Year Pi3C1Cf Warranty"25.Year Linear POW1 W(TYgTty COMKIANI Modules per box:26 pieces T Ina Solar L€mlted _._......_ ......... ... _ ......................... - w Modules per RO"container:728 pieces r a � ;,l00% -- o Addit(o naf value fT 0 90% TPon4f7(atS f{'g}ear CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. �oMPATje a ® q j¢(� Co 2015 Tr-no Solar Limited.All rights reserved.Specifications included In this dateshaet are subject to Trinasolar O 80% sofa change wthout notice. ,,n,ar Er ,ay Tggetheer " arr Years 5 10 15 20 25 Mono Multi Solutions DIMEfNSiONS OP"v J,A0 1Ui.F ei.E TYit;4A DATA,;STC Vr,N"'m Peak Power WattS-P.nx(WP) 245 250 255 260 941 Power Output Tolerance-Prnnx(%J 0-+3 Maximum Power Voltage-Vmr(V) 29.9 30.3 30.5 30.6 TH E Tir i na r iiiiiiiiin o u n t o aoncn. j o Maximum Power Current-Imp,(A) `8.20 8.27 8-37 8.50 o Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 umc Ore Short Circuit Current-Ise JA) 8.75 879 8.86 9.00 S Module Efficiency qm(�� 15.0 15.3 15.6 15.9 MODULE STC:Irradiance 1000 W/m'.Cell Temperature 25°C.Air Mass AM7.5 accortling fo EN 60904-3. Typical efficiency reduction.14.5 e at 200 W/,'..cording to EN 60904-I. 0 O �a O O �� i Maximum Power-PM x(Wp) 182 186 190 193 Maximum Power Voltage•V-(v) 27.6 28.0 28.1 28.3 MULT#C'RYSTALLINE MODULE Maximum PowerCarrent-lmrr(A) 6.59 6.65 6.74 6.84 WITH TRINAMOUNT FRAME onuH ore A A Open Circuit Voltage(V)-V-IV) 35.1 35.2 35.3 35.4 Short Circuit Current(A)-Isc(A) 7.07 7.10 7,17 7.27 //� [/�/ NOCT:Irradiance at 800 w/m'.Ambient Temperature 20°C,Wind Speed I m/s. Aw - V 180 PD05.18 Back view POWER OUTPUT RANGE ,SEC E AINICAi DATA 11 Solarcells Multicrystalline 156=156 mm J6 inches) East and simple to install through strop in mounting solution Cell orientation 40 cells(6*10) Q'" Module dimensions 1650 x 992 z 40 mm(64.95 z 39.05 z 1.57 inches) /{ 15.9 Weight .213 k9 J4701bs) MAXIMUM EFFICIENCY , , -„ E°efed T N� Glass M 33 fft .3 re#�);?+�h � �,,Tt - --- A-A Backsheet .. ...White Goad aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove --+37 tP 65 or olt b7 rated vV��(( i-V CURVES OF to COPUi.E(245W) J-Box _ Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), to.- -- 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 9°_-_1000W7m--- B Fire Rating Type 2 Highly reliable due to stringent quality control Q'- 600WIm' 5 -5- 600WIm' u_"OO T`- O ro '�0, TG is i,jF'; � _..- ,� ;=1r ��� ._,.A --_ u 4- >r00wfm= - T R2 PE�A`URE RATINGS �4AX1A'?ll0.�i RAT€FIGS ;. r I1: f v c 1 t_.is - ` 2�. 20owlm' Nominal Operating Cell Operational Temperature 40-+85°C c t �r _ ... Temperature JNOCT) 44°C(±2-C) System 1040V 6C(IEC ) o'w 10° 20.r 30.a 40.F Temperature Coefficient of P- 0.41%/°C Voltage I000V DC(Ut t ce cirOund IN', } -Tv i > Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating ISA vdtage(V) E Certified to withstand challenging enviresnmentca renperarurecaetfiaiematlsc 0.05%/^c conditions .� tr'ng f kct-,I WARRANTY Af'iTY e G 10 year Product Workmanship Warranty r 25 year Linear Power Warranty (Please rater to product warranty for details) a c .1'ic T.4t avC t CERTIFICATION LINEAR PERFORMANCE WARRANTY I A,_^ r Year _ __ __._._.._._ .... _._..___ ............... ,.___ c�w RA=jai,r~<c cOay. E.ua>T,..,!� -� -- p Sltus Modules per 40'container:728 pieces 7r1 as Solar Limited c5tfv .� I0 Year Product Warranty 25 Year Linear Power Warrant _ per box.26 pieces 0 90% anal Yalae ffa rflna$blaP s/in, T 1''`Cf.tanty co�Ei+l CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT�"y¢` ©2014 Tr Solar Umited.All rights reserved.Spec'rcations included,,this dot-ti aresublect to �.li..4! j Boy f4 kB change -thous notice. SmanEnergy her Years 5 10 IS 20 25 �oMPPt�Ov solar " e e = solar ' ® • SolarEdge Power Optimizer Module Add-On for North America P300 ! P350 ! P400 SolarEdge Power Optimizer Module Add-On For North America P800 P350 F400 (for 60-cell PV (for 72-cell PV (for 96-cell PV ''.. modules) modules) modules) INPUT P300 / P350 / P400 _ Rated Input DC Power")_ 300 350 400 T W p ut Voltage(V c at lowest temperature) 4 8 8 MPPTOperatigRange 848 860 880 Vdc Maximum Short Circuit Curent(Isc) 10 Adc y. z • Maximum DC Input Current 12.5 Adc & 7 M ax mum Efficiency 99 5 Weighted Efficiency 988 Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) 1- Maximum Output Current 15 Adc t� Maximum Output Voltage_ -_ _ 60 _ ..Vdc A OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety 1EC62109-1(class safety),OL1741 't�/ � rte,. ,n ' RoI1S Yes " r ti „s•" INSTALLATION SPECIFICATIONS_ y Maximum Allowed System Voltage 1000 Vdc vu Di menslons(W x L a E) 141 x 212 x 40.5/5.55 x 8.34 x 1.59 mm/in y Wei ht(including cables) 950/2.1 gr/Ib I HZU Input Connector MC4/AmphenolJTyro _ Output Wire Type/Connector Double Insulated;Amphenol _Output Wire Length 0.95/3.0 1.2/3.9 m/ft �. Operating Temperature Range �0-t85/-40-+185 it Protection Rating - IP65/NEMA4 Relative Humidity 0-100 ao:onnemoa�e.moue pvos po e.so ea�<:a owea. .— PV SYSTEM DESIGN USING A SOLAREDGE - SINGLE PHASE THREE PHASE THREE PHASE ,. .y -n INVERTER 208V 480V PV power.optimization at the module"level MinimumString Length(Power Optimizers) _. 8...__. ..... 10 .. 18 __ ....._ �`4)p to 2S% Poore energy Maximum String Length(Power Optimizers) 25 25 50 «°Superior efficie ncy(99.59u) Maximum Power per String 5250 6000 12750 W Yes o -:Mitigates a#types of mixdule mismatch losses,from manufacturing tolerance to partiaf shading Parallel Strings of Different Lengths r Orientations Flexible system design for maximum space utilization Fast Installation with a single bolt - Next generation maintenance with module-level monitoring ..Module-level voltage shutdown for installer and firefighter safety _.. N R ww',..,,-a -dge.:Ls i �I ^SolarCity ®pSolar Next-Level PV Mounting Technology '+^SOlafClty ®pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs f 3 Upra>o# ' Leveling Foot w- GaouMZep -_.It+tartock , , __ Part No.850-1172 ETL listed to UL 467 ti m E E Zep compaftle PV Mod¢le t _ ': 2ep[itaave ' Raat Attachment �a�.yskrrt °i' i Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 GOMPAT/, �� ,F Description p PV mounting solution for composition shingle roofs cal ~FA �� Works with all Zep Compatible Modules 4f C°Mpp, Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip �L usrelo Specifications Part No.850-1388 Part No,850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain k1k Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, zepsolar.com zepsolar.com Listed o L 156567 Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: ,• • •n: Label Location: -- :. - V1/ARNING -- .�- WARNING .'_ Code:ELECTFtiC SHUCK HAZARD � ELECTRIC SHOCK HAZARD 690.31.G.3 DO NUT TOUCH TERMINALS ' 1 THE 5160163 NDUCTORS OF THIS 690.35(F) Label Location: TERMINALS ON BATH LINE AND PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN INV LUAD SlL7ES MAY BE ENERGIZED UNGROUNDED AND PHOTOVOLTAIC DC !N THE OPEN POSITlUN MAY BE ENERGIZED UNGROUNDED- Per Code:DISCONNECT NEC ••/ Label Location: Label Location: MAXIMUM POWER-- D INTERCONNECTION Code: A WARNING: ELECTRIC SHOCK POINT CURRENT(Imp) ••- 690.17.4; 690-54 HAZARD. DO NOT TOUCH MAXIMUM POWER- V NEC 690.53 TERMINALS.TERMINALS ON POINT VOLTAGE(Vmp)- BOTH THE LINE AND LOAD SIDE MAXIMUM SYSTEM V MAY BE ENERGIZEd IN THE OPEN VOLTAGE(Voc)_ SHORT-CIRCUIT POSITION. FOR SERVICE CURRENT(Isc)_A DE-AND MAIN BREAK OR RCE PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT _ MAXIMUM AC OPERATING VOLTAGE _ V Label Location: WARNING ' P er ..- ELECTRIC SHOCK HAZARD 690.5(C) IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED Label L• • CONDUCTORS MAY BE C�AU-I-ION UNGROUNDED AND ENERGIZED DUAL POWER'SOURCE Per Code: SECOND SOURCE IS 690.64.13.4 PHQTOVOLTAIC SYSTEM Label • • WARNING ' P er Code: Label Location: ELECTRICAL SHOCK HAZARD DONOTTOUCHTERMINALS NEC 690.17(4) CAUTION ') (PO TERMINALS ON BOTH LINE AND Per ••- LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM 690.64.B.4 IN THE OPEN POSITION CIRCUIT IS BACKFED DC VOLTAGE IS' ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSEb TO SUNLIGHT Label • • WARNING -• Per ..- INVERTER OUTPUT Label • • CONNECTION 690.64.B.7 PHOTUVOLTAIG AC -• DO NOT RELOCATE ' AC Disconnect DISCONNECT Per Code: THISOVDRCC�RRENT Conduit NEC 6.1 :. Conduit(D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Label Location: (INV): Inverter With Integrated DC Disconnect MAXffAUM AC A ' - OPERATING CURRENT •t• Center _ Meter(M): Utility MAXI(V9UM AC OPERATING VOLTAGE V NEC 690.54 (POI): Point of • • r r r• r r r � r � r• � r r a r •• r• � � r r .., r r r r r r r r r .•- r i r •► r � r tiar r r GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO ONE (E) GROUND Panel Number:LC230PC Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ##SE5000A-USOOOSNR LABEL: A -(19)TRINA SOLAR ## TSM-260PDO5.18 GEN #168572 ROD AND ONE (N) GROUND ROD AT Meter Number:098 642 535 Tie-In: Supply Side Connection Inverter; 500'OW, 240V, 97.574 w/Unifed Disco and ZB,RGM,AFCI PV Module; 250W, 236.9W PTC, 40MM, Black Frome, H4, ZEP, 1000V ELEC 1136 MR PANEL WITH IRREVERSIBLE CRIMP Underground Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER (E) WIRING CUTLER-HAMMER Inverter 1 Disconnect CUTLER-HAMMER 20OA/2P 4 Disconnect 3 SOLAREDGE A I DC. - - - A 30A SE5000A-USOOOSNR2 DG I MP1: 1x10 B 21.V r------------- -------- ------------ EGC------------------ A Lt B ^ L2 1 I DC+ 1 I N DG I 2 I } (E) LOADS GND _ ---- GND -------------------------- _EG_G --- DC+ + Fpkw GEC N DG c MP2: 1x9 1 r----J EGC--- --------------------- ------------- G -----------------tJ I , N (1)Conduit Kit; 3/4' EMT o EGCIGEC Z C� I I I I I I - GEC T-1 TO 120/240V SINGLE PHASE I I UTILITY SERVICE 1 I I I I I I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP Ol (i)G5 8 Rod A (1)CUTLER-HAMMER /DG222NRB ^ PV (19)SOLAREDGE 3DD-2NA4AZS D� -(2)ILS//CO XIPC M /6 Disconnect; 60A, 24OVac, Fusible, NEMA 3R A PowerBox Optimizer, 30OW,H4, DC to DC, ZEP Insulation Piercing Connector Main 4/0-4, Tap 6-14 6 (I)CU.TLER-HAMMER #DG221UR6 (1)AM/6, Solid Bare Copper S Disconnect; 30A, 24OVac, Non-Fusible, NEMA 3R nd SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE -0)CUTLER-�IAMMER DG030N8 -(1)Ground Rod; 5/8" x 8', Copper AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Ground eutrd It 30A, Generd Duty(DG) (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE ....m.__............... _........ .. ___ ___._.__._..__.__ __...._ _ ..____ . - _____.... __._ .._______ .__..._____ . ..... .__ ..._... -__. ®� 1�AWG/6, THIN-2, Black V)AWG)AM/10, THWN-2, Block (2)AWG 0, P .._ _ _ __* __.. .�. (1)AWG�, THWN-2, Red )AWG/10, THIN-2, Red 1 AM V Wire 600V, �adc Voc -500 VDC Isc =15 ADC (1)AWG #6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=21 AAC /10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=21 AAC O ( ) , Sdid Bare Copper EGC Vmp -350 VDC Imp=7 33 ADC .. . . . . . . (1)Conduit Kit; 3 4' EMT . . . . .7.(j AWG #6, Solid Bare.Copper, GEC. . . .-(1)Conduit_Kit;.3/4'.EMT. . . . . . .. . . . . . . . . . .-(1)AWG/t3, TI{WN 72,,trees , EGC/GEC_-(1)Conduit Kit; 3/4'.EMT. . . . . . . . (2)AWG 00, PV Wire, 600V, Block Voc* -500 VDC Isc -15 ADC O (I)AM#6, Solid Bare Copper EGC Vmp =350 VDC Imp=6.6 ADC (1)Conduit Kit; 3/4' EMT I i CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-0101706 00 y wO� ���t CUNNINGHAM, BETHANY CUNNINGHAM RESIDENCE Gar Ermonn `J a y BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTgHG SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 41 AVIS CIR 0ov PART TO OTHERS OUTSIDE THE RECIPIENT'S Comp Mount Type C 4.94 KW PV ARRAY ►�� ORGANIZATION, EXCEPT IN CONNECTION WITH MODUL . NORTHAMPTON, M A 01062 THE SALE AND USE OF THE RESPECTIVE (19) TRINA SOLAR # TSM-260PDO5.18 24 St Martin Drive,Building Z Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NMI: SHEET: REV: DATE Marborough, MA 01752 PERMISSION of SOLARCITY INC. 9 87 6 54-3210 P V 4 11 20 2015 T. (65D)636-1026 F: (650)638-1029 SOLAREDGE SE5000A-USOOOSNR2 THREE LINE DIAGRAM / / ( )-SOL-CITY(765-2469) www.adarcit.com S1 (E) 2x4 (E) 2x4 H S1 H 13'-2" 70, 11'-5" ol 1'-1 (E) LBW 1'-1 (E) LBW A SIDE VIEW OF MP1 NTS B SIDE VIEW OF MP2 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING I Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 18" PORTRAIT 48" 18" RAFTER 2X8 @ 16"OC ROOF AZI 177 PITCH 27 STORIES: 2 RAFTER 2x8 @ 16"OC ARRAY AZI 177 PITCH 27 STORIES: 2 ARRAY AZI 177 PITCH 27 C.J. 2x8 @16"OC Comp Shingle C.T. 2x8 @16" OC Comp Shingle PV MODULE _ 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE �9 ZEP LEVELING FOOT O El LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT 6 HOLE. JASON WIL IAM � (4) (2) SEAL PILOT HOLE WITH TOM AN POLYURETHANE SEALANT. 0 STRUCTURAL ZEP COMP MOUNT C —— Na a15S ZEP FLASHING C (3) (3) INSERT FLASHING. toO�- QI T *4f (E) COMP. SHINGLE (4) PLACE MOUNT. s6dAL (1) 2/2015 (E) ROOF DECKING (2) (5) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES �STAL VELING FOOT WITH WITH SEALING WASHER ( & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF Si Scale: 1 1/2" = i' CONFlDENRAL— THE INFORMATION HEREIN JOB NUMBER: J B-01017 0 6 00 PREMISE OYMER: DESCRIPTION: DESIGN: �\\�� � CONTAINED SHALL NOT BE USED FOR THE CUNNINGHAM, BETHANY CUNNINGHAM RESIDENCE Gary Ermann i,`cOlar•�I}" BENERT OF ANYONE EXCEPT SOLARGTY INC., MOUNTING SYSTEM: x'•40 J 1.J/m NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 41 AVIS CIR 4.94 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES NORTHAMPTON MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH , 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (19) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME SHEET• REV: DATE: Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE5000A—USOOOSNR2 (98 7) 654-3210 STRUCTURAL VIEWS PV 3 11/20/2015 (866)—soL-C6TY(765-2469) www.solarcity.corn PITCH: 27 ARRAY PITCH:27 MP1 AZIMUTH: 177 ARRAY AZIMUTH: 177 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 27 ARRAY PITCH:27 ® ® MP2 AZIMUTH: 177 ARRAY AZIMUTH: 177 MATERIAL:Comp Shingle STORY: 2 Stories JASON WIL IAM OMAN-4 4 T##RU,17U. L s YQ.5155 +'ST0' , s11 NAt ' 2/2015 Inv Digitally signed by Jason Toman AC A,-, Date:2015.11.22 22:57:34-07'00' MP2 Or d� LEGEND D ,I (E) UTILITY METER & WARNING LABEL A Ins INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DISCONNECT & WARNING LABELS Front Of House J©1 AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS LOAD CENTER & WARNING LABELS =r DEDICATED PV SYSTEM METER STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED (E)DRIVEWAY �� '� INTERIOR EQUIPMENT IS DASHED L—'J SITE PLAN N 41 Avis Cir Scale: 3/32" = 1' 01' 10' 21' CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-01 01 706 00 SSE OWNER. DESCRIPTION. DEAN: CONTAINED SHALL NOT BE USED FOR THE CUNNINGHAM, BETHANY CUNNINGHAM RESIDENCE Gary Ermann ,,`�OI���'}` , BENEFIT OF ANYONE EXCEPT saARCITY INC., 11011NTNC SYS>EM: 41 A VI S C I R 1.y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN '� PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C 4.94 KW PV ARRAY ORGANIZATION, EXCEPT IN CONNECTION W9TH MODULES: NORTHAMPTON, M A 01062 THE SALE AND USE OF THE RESPECTIVE (19) TRINA SOLAR # TSM-260PDO5.18 1 1 24 SL Mortin Drive,Building 2,Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PACE NAME SHEET: REV: DATE Marlborough,MA 01752 PERMISSION of soLARaTY INC. SOLAREDGE SE5000A-USOOOSNR2 (987) 654-3210 SITE PLAN PV 2 11/20/2015 (888)-8OL) CITY(765-2489)6www.adacii�am ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING CITY OF NORTHAMPTON EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BUILDING DEPARTMENT FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY These plans have been reviewed HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL And approved. Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(8). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Date kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY S;g nature NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * * s * * * UTILITY: National Grid USA (Massachusetts Electric) * * * * * * J B-0101706 00 �°" DWNER: DESCRIPTION: °E " CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: \��1: ■ CONTAINED SHALL NOT BE USED FOR THE CUNNINGHAM, BETHANY CUNNINGHAM RESIDENCE Gary Ermann .�i,;(�Olar�'}�, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •��J 1.r• NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 41 AVIS CIR 4.94 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON MA 01062 THE ASALE D EXCEPT SE OF IN THE CONNECTION SPECTIVE�TM 19 TRINA SOLAR TSM-260PDO5.18 24 St Moron Drive,Budding 2 Unit it SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ( ) # PAGE NAME: SHEET: REV DATE T: (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. � SOLA LAREDGE SE5000A—USOOOSNR2 (987) 654-3210 COVER SHEET PV 1 11/20/2015 (888)-soL—CITY(765-2489) www.sdarcitycom CALCULATION OF DESIGN WIND LOADS - ALLIMPS Mounting Plane information Roofing Material Comp Roof PV System Type SolarCity SleekMounttm Spanning Vents No Standoff(Attachment Hardware) Comp Mount Type C Roof Slope 270 Rafter Spacing 16"O.C. Framing Type/Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA ,Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig,6-11B/C/D-14A/B ,Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor KA 1,00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor 1 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(VA2)(1) Equation 6-15 16.7 psf Wind Pressure Ext. Pressure Coefficient(Up) GC,(up) -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient(Down) G 0.45 Fig,6-11BIC/D-14A16 Design Wind Pressure p p = qh (GC) Equation 6-22 Wind Pressure Up Rum -14.6 psf Wind Pressure Down P(dom) 1 10.0 Psf ALLOWABLE STANDOFF SPACINGS X-01recdon Y-011rectianff Max Allowable Standoff Spacing Landscape 64" 39" Max Allowable Cantilever Landscape 24I NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -225lbs Uplift Capacity of Standoff T-allow 500lbs Standoff Demand/Ca P -acity DCR 45.1% X-01rectlon Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 181, NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual i -281 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity OCR 56.2% LOAD ITEMIZATION -ALL MRS Roof Dead Load Material Load Roof Category Description ALL MPS Existing Roofing Material Comp Roof (;2 Layers) 5.0 psf Re-Roof No Underlaymet Roofing Paper 0.5 psf Plywood Sheathing Yes 1.5 psf Board Sheathing None Rafter Size and Spacing 2 x 8 @ 16 in.O.C. 2.3 psf Vaulted Ceiling No Miscellaneous Miscellaneous Items 1.2 psf Total Roof Dead Load 10.5 psf' ALL MPS 10.5 Psf edu d#toof LL Non WAreas V41ue ASCE 7-05 Roof Live Load Lo 20.0 psf Table 4-1 Member Tributary Area At <200 sf Roof Slope 6/12 Tributary Area Reduction Ri 1 Section 4.9 Sloped Roof Reduction RZ 0.9 Section 4.9 Reduced Roof Live Load Lr Lr= 4!(Re)(R2) Equation 4-2 Reduced Road Live Load Lr 18 psr(ALL MPS) 18.0 D9f Reduced Ground Roof ve/Snow Leads 'Code Ground Snow Load p9 40.0 psf ASCE Table 7-1 Snow Load Reductions Allowed? Yes Snow Guards to be Installed? No I Effective Roof Slope 270 Horiz. Distance from Eve to Ridge W 16.0 ft Snow Importance Factor I, 1.0 Table'1.5-2 Snow Exposure Factor Ce Fully o 9posed Table 7-2 Structures kept just above freezing Snow Thermal Factor Ce 1.1 Table 7,3 Minimum Flat Roof Snow Load (w/ 28.0 psf 7.3.4&7.10 Rain-on-Snow Surcharge) Pf-min Flat:Roof Snow Load Pf pf=0.7(C$)(C<)(I)pg; pe �' pf-min Eq:7.3-1 28.0 psf 70% ASCE es n SlopW BW Snow Load Over arrauln acF Surface Condition of Surrounding Roof 4_roof All Other Surfaces Figure 7-2 Design Roof Snow Load Over N.r f (Cs-roof)Pf ASCE Eq:7.4-1 Surrounding Roof PS-roof 28.0 psf 70% ASCE DeWan Sloved-Roof Shed Loa d Over PV,Modules Surface Condition of PV Modules 4_PV Unobstructed Slippery Surfaces Figure 7-2 1.0 Design Snow Load Over PV P� P$-PV= (C5 )Pf ASCE Eq:7.4-1 Modules 28.0 psf 70% STRUCTURE ANALYSIS - LOADING SUMMARII AND MEMBER CHECK-ALL MPS` Member Proporties, mmary ALL MPS No' ontal,Member S . ns Rafter Pro es Overlhang 1.07 ft Actual W 1.50" Roof Wern Properties S in_1 13.17 ft Actual D 7.25" Number of Spans w/o Overhang) 1 Spain 2 Nominal Yes Roofing Material Comp Roof $ 3 A 10.88 in A2 Re-Roof No San 4 S. 13.14 in.A3 Plywood Sheathin Yes' S 5 I 47.63 in A4 Board Sheathing None Total R e S an 15.98 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 tart 7.50 ft Wood Species SPF Ceiling Finish 1/2"Gypsum Board PV 1 End 13.50 ft Wood Grade #2 Rafter Slope 270 PV T-tart Fe 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Ptart E` 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loa in Summary Roof Pitch 6/12 In l ial Pitch ust Mon-PV Areas PV Areas Roof Dead Load DL 10. psf x 1.12 11.8 psf 11.8 psf PV Dead Load PV-DL 3.0 sf x 1.12' 3.4 psf Roof Live Load RLL 20.0 psf x 0.90 18.0 psf Live/Snow Load LL/SL"' 40.1 psf x 0.7 j x 0.7 28.0 psf 28.0 psf Total Load(Governing LC TL I 1 1 39.8 psf 43.2 psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf= 0.7(Cj(Ct)(IS)pg; Ce=0.9,Ct=1.1,I5=1.0 Member Dsign S mma er NDS Governing Load Comb I CD' CL+ + CL - CF Cr D+S 1.15 1. 0 1 0.41 1 1.2 1.15 Member Ana 's Pesults Summary Governing Analysis Max Demand 0 Lo4ation ; CapacltV DCR Result Shear Stress 48 psi 1.1 ft. 155 psi 0.31 D i S Bending Stress 1079 psi 7.8 ft. 1389 psi 0.78 D+S Bending(-) Stress -35 psi 1.1 ft. -575 psi 0.06 D * S Total Load Deflection 0.69 in. 256 7.7 ft. 1.48 in. 1 L/120 0.47 D+S � R Version#53.4-TBD ty November 21, 2015 RE: CERTIFICATION LETTER JAS WIL [AM Project/Job# 0101706 -OMAN Project Address: Cunningham Residence 0 —4 41 Avis Cir 0 STRUCTURAL Northampton, MA 01062 0. 51554 Q 42" AHJ Northampton % T y ` SC Office Springfield NAL 22/2015 Design Criteria: -Applicable Codes = MA Res.Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 90 mph, Exposure Category C -Ground Snow Load=40 psf -ALL MPs: Roof DL = 10.5 psf, Roof LL/SL= 28 psf(Non-PV Areas), Roof LL/SL = 28 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22424< 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. This review relies on the roof's structural system having been originally designed and constructed in accordance with the building code requirements and having been maintained to be in good condition. Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. Digitally signed by Jason Toman Date:2015.11.22 22:57:20-07'00' 3055 Cieardiew Way Sar, Mateo,CA 94402 T(650)638-1028 (888)SOL.CIT`r` r(650)638-1029 sciarcity.corn DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Bethany Cunningham EXPLANATION OF THIS RIGHT. Docusigned by: 24. ADDITIONAL RIGHTS TO CANCEL. Signature: r� f��K IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL �� "_ "---` THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL THIS PPA AT NO COST AT ANY TIME PRIOR TO Date: 11/19/2015 COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after Customer's Name: 11/19/2015. If you don't sign this PPA and return it to us on or prior to 30 days after 11/19/2015,SolarCity reserves the right to reject this PPA unless you agree to our then Signature: current pricing. Date: Power Purchase Agreement SolarCity approved J Signature: Lyndon Rive, CEO Date: 11/19/2015 DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 20. Privacy/Publicity You grant SolarCity the right to publicly use,display,share, and advertise the photographic images, Project details, price and any other non-personally identifying information of your Project.SolarCity shall not knowingly release any personally identifiable information about you or any data associating you with the Project location.You may opt-out of these publicity rights by giving us written notice and mailing it to: SolarCity Corporation,Attention: Publicity Opt Out,3055 Clearview Way,San Mateo,CA 94402. 21. Notices. All notices under this PPA shall be in writing and shall be by personal delivery,facsimile transmission,electronic mail, overnight courier,or certified or registered mail,return receipt requested. 22. Entire Agreement;Changes. This PPA contains the parties'entire agreement regarding the sale and purchase of power generated by the System. There are no other agreements regarding this PPA,either written or oral. Any change to this PPA must be in writing and signed by both parties.Only an authorized officer of SolarCity may execute any change to this Agreement on behalf of SolarCity. If any portion of this PPA is determined to be unenforceable,the remaining provisions shall be enforced in accordance with their terms or shall be interpreted or re-written so as to make them enforceable. REST OF PAGE INTENTIONALLY LEFT BLANK. DocuSign Envelope ID:0D971710-29C2-4526-A879-B6018E726425 schedule a convenient time for SolarCity to remove the as a class action,class arbitration, private attorney general System from your Home at no cost to you. action or other representative action, nor may any such 18. Applicable Law;Arbitration. Dispute be pursued on your or our behalf in any litigation in any court.Claims regarding any Dispute and remedies PLEASE READ THIS SECTION CAREFULLY.ARBITRATION sought as part of a class action,class arbitration, private REPLACES THE RIGHT TO GO TO COURT, INCLUDING THE attorney general or other representative action are subject RIGHT TO A JURY AND THE RIGHT TO PARTICIPATE IN A to arbitration on an individual(non-class, non- CLASS ACTION OR SIMILAR PROCEEDING. IN ARBITRATION, representative) basis,and the arbitrator may award relief A DISPUTE IS RESOLVED BY AN ARBITRATOR INSTEAD OF A only on an individual (non-class, non-representative) basis. JUDGE OR JURY. This means that the arbitration may not address disputes The laws of the state where your Home is located shall involving other persons with disputes similar to the govern this PPA without giving effect to conflict of laws Disputes between you and SolarCity. principles.We agree that any dispute,claim or The arbitrator shall have the authority to award any legal or disagreement between us(a "Dispute")shall be resolved equitable remedy or relief that a court could order or grant exclusively by arbitration. under this agreement.The arbitrator,however,is not The arbitration, including the selecting of the arbitrator,will authorized to change or alter the terms of this agreement be administered by JAMS, under its Streamlined Arbitration or to make any award that would extend to any transaction Rules(the"Rules") by a single neutral arbitrator agreed on other than yours.All statutes of limitations that are by the parties within thirty(30)days of the commencement applicable to any dispute shall apply to any arbitration of the arbitration. The arbitration will be governed by the between us. The arbitrator will issue a decision or award in Federal Arbitration Act(Title 9 of the U.S.Code). Either writing,briefly stating the essential findings of fact and party may initiate the arbitration process by filing the conclusions of law. necessary forms with JAMS.To learn more about BECAUSE YOU AND WE HAVE AGREED TO ARBITRATE ALL arbitration,you can call any JAMS office or review the DISPUTES, NEITHER OF US WILL HAVE THE RIGHT TO materials at www.jamsadr.com.The arbitration shall be LITIGATE THAT DISPUTE IN COURT,OR TO HAVE A JURY held in the location that is most convenient to your Home. TRIAL ON THAT DISPUTE,OR ENGAGE IN DISCOVERY If a JAMS office does not exist within 50(fifty)miles of your EXCEPT AS PROVIDED FOR IN THE RULES. FURTHER,YOU Home,then we will use another accredited arbitration WILL NOT HAVE THE RIGHT TO PARTICIPATE AS A provider with offices close to your Home.. REPRESENTATIVE OR MEMBER OF ANY CLASS PERTAINING If you initiate the arbitration,you will be required to pay the TO ANY DISPUTE.THE ARBITRATOR'S DECISION WILL BE first$125 of any filing fee. We will pay any filing fees in FINAL AND BINDING ON THE PARTIES AND MAY BE excess of$125 and we will pay all of the arbitration fees ENTERED AND ENFORCED IN ANY COURT HAVING and costs. If we initiate the arbitration,we will pay all of JURISDICTION, EXCEPT TO THE EXTENT IT 15 SUBJECT TO the filing fees and all of the arbitration fees and costs. We REVIEW IN ACCORDANCE WITH APPLICABLE LAW will each bear all of our own attorney's fees and costs GOVERNING ARBITRATION AWARDS.OTHER RIGHTS THAT except that you are entitled to recover your attorney's fees YOU OR WE WOULD HAVE IN COURT MAY ALSO NOT BE and costs if you prevail in the arbitration and the award you AVAILABLE IN ARBITRATION. receive from the arbitrator is higher than SolarCity's last 19. Waiver. written settlement offer. When determining whether your award is higher than SolarCity's last written settlement Any delay or failure of a party to enforce any of the offer your attorney's fees and costs will not be included. provisions of this PPA,including but not limited to any remedies listed in this PPA,or to require performance by Only Disputes involving you and SolarCity may be addressed the other party of any of the provisions of this PPA,shall in the arbitration. Disputes must be brought in the name of not be construed to(i)be a waiver of such provisions or a an individual person or entity and must proceed on an party's right to enforce that provision;or(ii)affect the individual(non-class,non-representative) basis.The validity of this PPA. arbitrator will not award relief for or against anyone who is not a party. If either of us arbitrates a Dispute, neither of us, nor any other person, may pursue the Dispute in arbitration DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 SOLARCITY'S LIABILITY TO YOU UNDER THIS POWER (b)take any reasonable action to correct your default or to PURCHASE AGREEMENT SHALL BE LIMITED TO DIRECT, prevent our loss;any amount we pay will be added to ACTUAL DAMAGES ONLY. YOU AGREE THAT IN NO the amount you owe us and will be immediately due; EVENT SHALL EITHER PARTY BE LIABLE TO THE OTHER (c) require you,at your expense,to return the System or FOR CONSEQUENTIAL, INCIDENTAL, PUNITIVE, make it available to us in a reasonable manner; EXEMPLARY,SPECIAL OR INDIRECT DAMAGES. (d)proceed, by appropriate court action,to enforce (b)Actual Damages performance of this PPA and to recover damages for EXCEPT FOR CLAIMS UNDER SECTION 5(H), NEITHER your breach; PARTY'S LIABILITY TO THE OTHER WILL EXCEED AN AMOUNT EQUAL TO THE MAXIMUM AMOUNT THAT (e)disconnect,turn off or take back the System by legal process or self-help, but we may not disturb the peace COULD BE PAYABLE BY YOU UNDER SECTION 16(H). or violate the law; DAMAGES TO YOUR HOME, BELONGINGS OR PROPERTY RESULTING FROM THE INSTALLATION OR OPERATION (f) report such non-operational status of the System to OF THE SYSTEM ARE COVERED IN SECTION 6(C)OF THE your utility, informing them that you are no longer net LIMITED WARRANTY. metering; 15. Default. (g) charge you a reasonable reconnection fee for reconnecting the System to your utility or turning your You will be in default under this Power Purchase System back on after we disconnect or turn off the Agreement if any one of the following occurs: System due to your default; (a) you fail to make any payment when it is due and such failure continues for a period of ten (10)days; (h) recover from you (i)a payment equal to the purchase price as set forth in this agreement plus (ii)all taxes, (b) you fail to perform any material obligation that you late charges, penalties,interest and all or any other have undertaken in this PPA(which includes doing sums then accrued or due and owing;or something you have agreed not to do,like alter the (i) use any other remedy available to us in this PPA or by System)and such failure continues for a period of law. fourteen(14)days after written notice; We may submit to credit reporting agencies(credit (c) you or your guarantor have provided any false or ' bureaus) negative credit reports that would be reflected on misleading financial or other information to obtain this your credit record if you do not pay any amounts due Power Purchase Agreement; under this PPA as required. (d) you assign,transfer,encumber,sublet or sell this PPA or You agree to repay us for any reasonable amounts we pay any part of the System without SolarCity's prior written to correct or cover your default.You also agree to consent;or reimburse us for any costs and expenses we incur relating (e) you or any guarantor makes an assignment for the to the System's return resulting from early termination. By benefit of creditors, admits in writing its insolvency, choosing any one or more of these remedies,SolarCity files or there is filed against you or it a voluntary does not give up its right to use another remedy. By petition in bankruptcy, is adjudicated bankrupt or deciding not to use any remedy should this Power insolvent or undertakes or experiences any substantially Purchase Agreement be in default,SolarCity does not give similar activity. up our right to use that remedy in case of a subsequent 16. Remedies in Case of Default. default. If this Power Purchase Agreement is in default,we may 17. System Removal; Return. take any one or more of the following actions. If the law At the end of the Term or the termination of this PPA, if requires us to do so,we will give you notice and wait any you have not renewed this PPA or exercised your purchase period of time required before taking any of these actions. option(if any)and you have not defaulted,then within We may: ninety(90)days you agree to call SolarCity at the (a) terminate this PPA; telephone number listed in Section 7 of Exhibit 2 to ED15i�1;:i DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 (30)days prior to a renewal term that you do not wish to your approved buyer and SolarCity shall execute a renew; or(ii)we send you a notice terminating the PPA. written transfer of this PPA. 12. Selling Your Home. (c) If you sell your Home and can't comply with any of the (a) If you sell your Home you can: options in subsection(a)above,you will be in default under this Power Purchase Agreement. Section 12(a) (i)Transfer this Power Purchase Agreement and the includes a Home sale by your estate or heirs. Monthly Payments (d) Free Assumability.This agreement is free of any The person buying your Home (the"Home Buyer") restrictions that would prevent the homeowner from can sign a transfer agreement assuming all of your freely transferring their home("Property').SolarCity rights and obligations under this Agreement by will not prohibit the sale,conveyance or refinancing of qualifying in one of three ways: the Property.SolarCity may choose to file in the real 1) The Home Buyer has a FICO score of 650 or estate records a UCC-1 financing statement("Fixture greater; Filing")that preserves their rights in the System.The 2) The Home Buyer is paying cash for your Fixture Filing is intended only to give notice of its rights Home;or relating to the System and is not a lien or 3) If the Home Buyer does not qualify under(1) encumbrance against the Property.SolarCity shall or(2),the Home Buyer qualifies for a explain the Fixture Filing to any subsequent purchasers mortgage to purchase your Home and either of the Property and any related lenders as requested. you or the Home Buyer pays us a$250 credit SolarCity shall also accommodate reasonable requests exception fee. from lenders or title companies to facilitate a (ii)Move the System to Your New Home purchase,financing,or refinancing of the Property. Where permitted by the utility(s),the System can be (e) EXCEPT AS FORTH IN THIS SECTION,YOU WILL NOT moved to your new home pursuant to Section 4 of ASSIGN,SELL, PLEDGE OR IN ANY OTHER WAY the Limited Warranty.You will need to provide the TRANSFER YOUR INTEREST IN THE SYSTEM OR THIS same rights to SolarCity as provided for in this PPA PPA WITHOUT OUR PRIOR WRITTEN CONSENT,WHICH and provide any third party consents or releases SHALL NOT BE UNREASONABLY WITHHELD. required by SolarCity in connection with the substitute premises. (iii)Prepay this Power Purchase Agreement and 13. Loss or Damage. Transfer only the Use of the System (a) Unless you are grossly negligent,you intentionally At any time during the Term,you can prepay this damage the System,or damage or loss to the System is Power Purchase Agreement in full by paying caused by ball strikes,SolarCity will bear all of the risk SolarCity the expected remaining payments of loss,damage,theft,destruction or similar occurrence (estimated future production during the rest of the to any or all of the System. Except as expressly Term multiplied by the average kWh rate during the provided in this PPA,no loss,damage,theft or rest of the Term)at a five percent(5%)discount destruction will excuse you from your obligations under rate.The person buying your Home will only need to this PPA,including Monthly Payments. sign a transfer agreement to assume your rights and non-Monthly Payment obligations under this PPA. (b) If there is loss,damage,theft,destruction or a similar The System stays at your Home,the person buying occurrence affecting the System,and you are not in your Home does not make any Monthly Payments default of this PPA,you shall continue to timely make all and has only to comply with the non-Monthly Monthly Payments and pay all other amounts due Payment portions of this PPA. under the PPA and,cooperate with SolarCity,at SolarCity's sole cost and expense,to have the System (iv)Purchase the System(see Section 10) repaired pursuant to the Limited Warranty. (b) You agree to give SolarCity at least fifteen (15)days but not more than three(3) months prior written 14. Limitation of Liability. notice if you want someone to assume your PPA (a) No Consequential Damages obligations. In connection with this assumption,you, DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 transfer the System and this Power Purchase Agreement, monitoring issues.Your failure to cooperate with SolarCity or any part of this Power Purchase Agreement or the with respect to Internet requirements will result in your exhibits,without your consent. This assignment does not obligation to compensate SolarCity for all lost SREC or change SolarCity's obligation to maintain and repair your incentive revenue and related costs,subject to a monthly System as set forth in the Warranty. charge of no less than$10.00(ten dollars) per month until 9. Ownership of the System;Tax Credits and Rebates. adequate Internet monitoring is implemented or restored. You agree that the System is SolarCity's personal property 10. Purchasing the System Prior to the End of the Term. under the Uniform Commercial Code. You understand and In addition to purchasing the System at the end of the agree that this PPA is not a contract to sell or lease the Term,you have the option to purchase the System prior to System to you. SolarCity owns the System for all purposes, the end of the Term as detailed below. To exercise this including any data generated from the System. You shall at option you must be in good standing under this Power all times keep the System free and clear of all liens,claims, Purchase Agreement and you need to give us at least one levies and legal processes not created by SolarCity,and (1) month's, but not more than three(3) months' prior shall at your expense protect and defend SolarCity against written notice. You can purchase this System: the same. (i) on the five(5)year anniversary of the YOU UNDERSTAND AND AGREE THAT ANY AND ALL TAX beginning of the Term and every annual CREDITS, INCENTIVES, RENEWABLE ENERGY CREDITS, anniversary after the five(5)year anniversary; GREEN TAGS,CARBON OFFSET CREDITS, UTILITY REBATES and OR ANY OTHER NON-POWER ATTRIBUTES OF THE SYSTEM (ii) at any time after the five(5)year anniversary ARE THE PROPERTY OF AND FOR THE BENEFIT OF of the beginning of the Term,when you sell SOLARCITY, USABLE AT ITS SOLE DISCRETION.SOLARCITY your Home;and SHALL HAVE THE EXCLUSIVE RIGHT TO ENJOY AND USE ALL (iii) if SolarCity ever ceases its operations. SUCH BENEFITS,WHETHER SUCH BENEFITS EXIST NOW OR IN THE FUTURE. YOU AGREE TO REFRAIN FROM ENTERING In each of(i),(ii)and (iii)above,the price you will pay for INTO ANY AGREEMENT WITH YOUR UTILITY THAT WOULD the System will be the System's fair market value("FMV"). ENTITLE YOUR UTILITY TO CLAIM ANY SUCH BENEFITS. A third party independent appraiser will be retained to YOU AGREE TO REASONABLY COOPERATE WITH SOLARCITY compute the System's FMV. SolarCity's maintenance and SO THAT IT MAY CLAIM ANY TAX CREDITS, RENEWABLE repair obligations under the Limited Warranty(Exhibit 2) ENERGY CREDITS, REBATES,CARBON OFFSET CREDITS OR will continue when you purchase the System until what ANY OTHER BENEFITS FROM THE SYSTEM.THIS MAY would have been the end of the original Term. INCLUDE TO THE EXTENT ALLOWABLE BY LAW, ENTERING 11. Renewal. INTO NET METERING AGREEMENTS, INTERCONNECTION AGREEMENTS,AND FILING RENEWABLE ENERGY/CARBON If you are in compliance with your PPA,you have the option OFFSET CREDIT REGISTRATIONS AND/OR APPLICATIONS to renew your PPA for up to ten(10)years in two(2)five(5) FOR REBATES FROM THE FEDERAL,STATE OR LOCAL year renewal periods. We will send you renewal forms three (3)months prior to the expiration of the Term,which forms GOVERNMENT OR A LOCAL UTILITY AND GIVING THESE TAX CREDITS, RENEWABLE ENERGY/CARBON CREDITS, REBATES shall set forth the new Monthly Payments due under the OR OTHER BENEFITS TO SOLARCITY. renewal PPA, based on our assessment of the then current fair market value of the System. If you want to renew, You understand that solar renewable energy credits complete the renewal forms and return them to us at least (SRECs)and certain incentives and associated data cannot one(1)month prior to the end of the PPA. In the event that be generated or earned without internet.As such,you you do not agree to the new Monthly Payments this PPA agree to maintain and make available,at your cost,a shall expire by its terms on the termination date. If you functioning indoor Internet connection with the don't send us anything in writing after we send you the understanding that Wi-Fi hotspotting,tethering and renewal forms,then this PPA shall renew for an additional intermittent Internet connection will not satisfy this one(1)year term at ten percent(10%) less than the then- obligation.You also agree to cooperate with SolarCity as current average rate charged by your local utility and shall necessary to provide any other information required to continue to renew for one(1)year terms at the same rate as generate SRECs or earn incentives and troubleshoot your first renewal until (i)you give us notice at least th;�+• c"j,i i r,i . not .rso ti'4 5 DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 ABSOLUTE AND UNCONDITIONAL UNDER ALL (v) confirmation that SolarCity will obtain all CIRCUMSTANCES AND SHALL NOT BE SUBJECT TO applicable benefits referred to in Section 9; ANY ABATEMENT, DEFENSE,COUNTERCLAIM, NO receipt of all necessary zoning, land use and SETOFF, RECOUPMENT OR REDUCTION FOR ANY building permits;and REASON WHATSOEVER, IT BEING THE EXPRESS (vii) completion of any renovations,improvements INTENT OF THE PARTIES THAT ALL AMOUNTS or changes reasonably required at your Home PAYABLE BY YOU HEREUNDER SHALL BE,AND or on the Property(e.g.,removal of a tree or CONTINUE TO BE, PAYABLE IN ALL EVENTS necessary roof repairs to enable us to safely INCLUDING BY YOUR HEIRS AND ESTATE AND, install the System). EXCEPT AS SET FORTH BELOW IN SECTIONS 6,23 AND 24,YOU HEREBY WAIVE ALL RIGHTS YOU MAY (viii) if your home is governed by a home owner's HAVE TO REJECTOR CANCEL THIS PPA,TO REVOKE association or similar community organization, ACCEPTANCE OF THE SYSTEM, OR TO GRANT A your receipt of all approvals and authorizations for the System required by that organization and SECURITY INTEREST IN THE SYSTEM. advising us of any requirements of that (j) Credit Check organization that will otherwise impact the You authorize SolarCity,or its designee,to obtain System,its installation or operation. your credit report now and in the future,check your SolarCity may terminate this Power Purchase credit and employment history,answer questions Agreement without liability if, in its reasonable others may ask regarding your credit and share your judgment,any of the above listed conditions(i) credit information with SolarCity's financing through(vii)will not be satisfied for reasons beyond partners.You certify that all information you provide its reasonable control. Once SolarCity starts to us in connection with checking your credit will be installation, however, it may not terminate this true and understand that this information must be Power Purchase Agreement for your failure to updated upon request if your financial condition satisfy conditions(i)through (vii)above. changes. (b) Amendments. 6. Conditions Prior to Installation of the System;Change The System's initial estimated production is set forth Orders. in this PPA.After System design,the estimated (a) SolarCity's obligation to install the System and sell production is likely to change and we will share you the power it produces is conditioned on the those changes with you prior to installation. If the following items having been completed to its estimated production increases or decreases by reasonable satisfaction: more than twenty percent(20%),we will document (i) completion of(A)the engineering site audit(a that change in an amendment.. thorough physical inspection of the Property, You authorize SolarCity to make corrections to the including, if applicable,geotechnical work),(B) utility paperwork to conform to this PPA or any the final System design,and(C) real estate due amendments to this PPA we both sign. diligence to confirm the suitability of the 7, Warranty. Property for the construction, installation and operation of the System; YOU UNDERSTAND THAT THE SYSTEM IS WARRANTED (ii) approval of this Power Purchase Agreement by SOLELY UNDER THE LIMITED WARRANTY ATTACHED AS one of SolarCity's financing parties; EXHIBIT 2,AND THAT THERE ARE NO OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR IMPLIED, (iii) your meeting the applicable credit score; AS TO THE MERCHANTABILITY, FITNESS FOR ANY PURPOSE, (iv) confirmation of rebate,tax credit and CONDITION, DESIGN,CAPACITY,SUITABILITY OR renewable energy credit payment availability in PERFORMANCE OF THE SYSTEM OR ITS INSTALLATION. the amount used to calculate the Monthly Payments set forth in this Power Purchase $ Transfer. Agreement; SolarCity will assign this PPA to one of its financing partners. You agree that SolarCity may assign,sell or DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 In addition to the other amounts you agree to pay in System or making any additions to the System this Power Purchase Agreement,you agree to pay the or installing complementary technologies on or following: about the location of the System;(B)enforcing (i) Automatic Payment Discount: If you make your SolarCity's rights as to this Power Purchase Monthly Payments by allowing us to Agreement and the System; (C)installing, using automatically debit your checking or savings and maintaining electric lines and inverters and account,then you will receive a discount of$7.50 meters, necessary to interconnect the System to on your Monthly Payments.The Monthly your electric system at the Property and/or to Payments listed in Section 4 of this Agreement the utility's electric distribution system; or(D) reflect this discount. If you do not allow the taking any other action reasonably necessary in automatic debit,this discount will not be applied connection with installing,constructing, to your Monthly Payments and each Monthly operating, owning, repairing, removing and Payment will be$7.50 greater; replacing the System.This access right shall continue for up to ninety(90) days after this (ii) Returned Check Fee:$25(or such lower amount Power Purchase Agreement expires to provide as required by law)for any check or withdrawal SolarCity with time to remove the System at the right that is returned or refused by your bank;and end of the Power Purchase Agreement. (iii) Late Payments:accrue interest at the lesser of SolarCity shall provide you with reasonable twelve percent(12%)annually or the maximum notice of its need to access the Property allowable by applicable law. whenever commercially reasonable. (e) Taxes (ii) During the time that SolarCity has access rights Your SolarCity electricity rate of$0.1200 per kWh is you shall ensure that its access rights are composed of an electricity rate of$0.1200 plus preserved and shall not interfere with or permit current taxes of$0.0000.You agree to pay any any third party to interfere with such rights or changes in the applicable taxes related to this PPA. access. You agree that the System is not a Thus, if tax rates change,your SolarCity electricity fixture, but SolarCity has the right to file any rate will change to reflect this rate change. If this UCC-1 financing statement or fixture filing that PPA contains a purchase option at the end of the confirms its interest in the System. Term,you agree to pay any applicable tax on the (h) Indemnity purchase price for the System.You also agree to pay To the fullest extent permitted by law,you shall as invoiced any applicable personal property taxes indemnify,defend, protect, save and hold harmless on the System that your local jurisdiction may levy. SolarCity,its employees,officers,directors,agents, (f) No Alterations successors and assigns from any and all third party You agree that you will not make any modifications, claims,actions,costs,expenses(including improvements, revisions or additions to the System reasonable attorneys'fees and expenses),damages, or take any other action that could void the Limited liabilities, penalties, losses, obligations, injuries, Warranty on the System without SolarCity's prior demands and liens of any kind or nature arising out written consent. If you make any modifications, of,connected with, relating to or resulting from your improvements, revisions or additions to the System, negligence or willful misconduct; provided,that they will become part of the System and shall be nothing herein shall require you to indemnify SolarCity's property. SolarCity for its own negligence or willful misconduct.The provisions of this paragraph shall (g) Access to the System survive termination or expiration of this Power (I) You grant to SolarCity and its employees,agents Purchase Agreement. and contractors the right to reasonably access (i) Payments all of the Property as necessary for the purposes SUBJECT TO SECTION 4(b)ABOVE,YOU AGREE THAT of(A)installing,constructing,operating, THE OBLIGATION TO PAY ALL PAYMENTS AND ALL owning, repairing, removing and replacing the OTHER AMOUNTS DUE UNDER THIS PPA SHALL RF DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 (i) only have the System repaired pursuant to the obtain all approvals and authorizations for the Limited Warranty and reasonably cooperate System required by that organization and advise when repairs are being made; us of any requirements of that organization that (ii) keep trees,bushes and hedges trimmed so that will otherwise impact the System,its installation the System receives as much sunlight as it did or operation. when SolarCity installed it; (b) System Construction,Repair,Insurance and (iii) not modify your Home in a way that shades the SolarCity's obligations: System; SolarCity agrees to: (iv) be responsible for any conditions at your Home (i) schedule the installation of the System at a that affect the installation(e.g., blocking access mutually convenient date and time; to the roof,or removing a tree that is in the way, prior work you have done on your home that was (ii) construct the System according to written plans not permitted); you review; (v) not remove any markings or identification tags (iii) provide you with a web-enabled meter to on the System; accurately measure the amount of power the System delivers to you; (vi) permit SolarCity,after we give you reasonable notice,to inspect the System for proper (Iv) provide you with a home energy evaluation; operation as we reasonably determine (v) notify you if the System design has to be necessary; materially changed so that you can review any (vii) use the System primarily for personal,family or such changes; household purposes, but not to heat a swimming (vi) clean up after ourselves during the construction pool; of the System; (viii) not do anything, permit or allow to exist any (vii) insure the System against all damage or loss condition or circumstance that would cause the unless(A)that damage or loss is caused by your System not to operate as intended at the gross negligence;or(B)that damage or loss is Property; caused by ball strikes;or(C)you intentionally (ix) notify SolarCity if you think the System is damage the System; damaged or appears unsafe;if the System is (viii) repair the System pursuant to the Limited stolen;and prior to changing your power Warranty and reasonably cooperate with you supplier; when scheduling repairs; (x) have anyone who has an ownership interest in (ix) create a priority stream of operation and your Home sign this Power Purchase Agreement; maintenance payments to provide enough cash (xi) return any documents we send you for signature flow in our financing transactions to pay for the (like incentive claim forms)within seven(7)days Limited Warranty obligations and the repair and of receiving them;and maintenance of the System in accordance with this PPA even if SolarCity ceases to operate;and NO maintain and make available,at your cost,a functioning indoor internet connection with a (x) not put a lien on your Home or Property. router,one DHCP enabled Ethernet port with internet access and standard AC power outlet (c) Home Renovations or Repairs close enough and free of interference to enable an If you want to make any repairs or improvements to internet-connected gateway provided by SolarCity the Property that could interfere with the System to communicate wirelessly with the system's (such as repairing the roof where the System is inverter(typically this is 80 feet,but may depend located),you may only remove and replace the on site conditions). See section 2(c)(ii)of the System pursuant to the Limited Warranty. Limited Warranty for details;and (xiii) if your home is governed by a home owner's (d) Automatic Payment,Late Charges,Fees association or similar community organization, M .� DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 1. Introduction. will debit your bank account on or about the 11t day of This Power Purchase Agreement(this"Power Purchase the next month following invoice(e.g.January invoices Agreement," "Agreement"or"PPA") is the agreement are sent in early February and debited on or about between you and SolarCity Corporation (together with its March 1). Monthly Payments will change as your price successors and assigns, "SolarCity"or"we"),covering the per kWh changes over the Term of this PPA and as sale to you of the power produced by the solar panel System production varies(e.g.,summer has higher system (the "System")we will install at your home. production).You will have regular access to the SolarCity agrees to sell to you,and you agree to buy from System's production via your SolarCity online account. SolarCity,all of the power produced by the System. The Payments due upon installation,if any,are due System will be installed by SolarCity at the address you immediately prior to commencement of installation. listed above (the"Property"or your"Home"). This Power You will make no Monthly Payments if you are fully Purchase Agreement is eight(8)pages long and has up to prepaying this PPA. In this case,you will pay only the three (3) Exhibits depending on the state where you live. amounts listed in the key terms summary on page one SolarCity provides you with a Limited Warranty(the of this PPA. "Limited Warranty"). The Limited Warranty is attached as (c) Estimated Production. If(i)the System is shut down for Exhibit 2. If you have any questions regarding this Power more than seven (7)full twenty-four(24) hour days Purchase Agreement, please ask your SolarCity sales cumulatively during the Term because of your actions; consultant. or(ii)you take some action that significantly reduces THIS AGREEMENT SUPERSEDES ALL PRIOR EXISTING the output of the System; (iii)you don't trim your CONTRACTS BETWEEN YOU AND SOLARCITY THAT PERTAIN bushes or trees to their appearance when you signed TO THE "SYSTEM" DEFINED IN THIS AGREEMENT. this PPA to avoid foliage growth from shading the System;or(iv)your System is not reporting production 2. Term. to SolarCity(e.g.you have disconnected the SolarCity agrees to sell you the power generated by the PowerGuide system or the internet connection at your System for 20 years(240 months), plus, if the Home goes down on the reporting day),then SolarCity Interconnection Date is not on the first day of a calendar will reasonably estimate the amount of power that month,the number of days left in that partial calendar would have been delivered to you during such System month. We refer to this period of time as the"Term." The or reporting outages or reduced production periods Term begins on the Interconnection Date. The ("Estimated Production")and shall consider Estimated "Interconnection Date" is the date that the System is Production as actual production for purposes of this turned on and generating power. SolarCity will notify you paragraph. In the first year of the Term, Estimated when your System is ready to be turned on. Production will be based on our production projections. After the first year of the Term, Estimated Production 3. Intentionally Left Blank. will be based on historical production for that month in 4. Power Purchase Agreement Payments;Amounts. the prior year. If we bill you for Estimated Production (a) Power Price. During the first year of the term,you are because your System is not reporting production to SolarCity,and we subsequently determine that we have purchasing all of the power the System produces for either overestimated or underestimated the actual $0.1200 per kWh. After the first year,the price per production,then we will adjust the next bill downward kWh will increase by 2.90%per year.There are no installation costs. (to refund overbilling)or upward (to make up for lost billing). You will not be charged for Estimated (b)Payments. Production when the System is not producing electricity Your monthly payments will be the product of(A)the due to SolarCity's fault,or if it's due to grid failure or price per kWh multiplied by(B)the actual kWh output power outages caused by someone other than you. for the calendar month ("Monthly Payments"). Invoices S. Power Purchase Agreement Obligations. for Monthly Payments will be mailed or emailed no (a) System,Home and Property Maintenance later than ten(10)days after the end of a calendar month. If you are paying your invoice by automatic You agree to: debit from your checking or savings account(ACH)we ❑ ❑ 0 DocuSign Envelope ID:OD971710-29C2-4526-A879-B6018E726425 SolarCity 1 PPA Customer Name and Address Installation Location Date Bethany Cunningham 41 Avis Cirlot 5 L5 Pole 2-1 11/19/2015 Northampton,MA 01062 41 Avis Cir Northampton,MA 01062 Here are the key terms of your Power Purchase Agreement $ UL 0 2 V Lou U System installation cost Electricity rat g kWh Agreeme Initial here Initial he DS The SolarCity Promise �C •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. .......... _....... ............... Initial here E,—, ___ •We warrant all of our roofing work. os •We restore your roof at the end of the Agreement. �jC •We warrant, insure, maintain and repair the System ....____.. _....... _ _........ ........_ .. ...... ..... .:...._ initial here_ •We fix or pay for any damage we may cause to your property. •We provide 24/7 web-enabled monitoring at no additional cost. •The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 11/19/2015. Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: .At certain times,as specified in $0 •SolarCity will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 -You can upgrade to a new System with •These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est.amount due at building inspection contract. not beyond that term. $0 .You may purchase the System from Est,first year production SolarCity for its fair market value as 5,358 kWh specified in the Agreement. •You may renew this Agreement for up to ten (10)years in two(2)five(5)year increments. 3055 Clearview Way, San Mateo, CA 94402 1 888,765.2489 1 solarcity.com 1329139 Power Purchase Agreement,version 9.1.0,November 11,2015 SAPC/SEFA Compliant Contractors License MA HIC 168572/EL-1136MR Document generated on 11/19/2015 5 Copyright 2008-2015 SolarCity Corporation,All Rights Reserved The CommonweafNr of Massacllusefts j.. Department of InrPuustrialAccirlents Office of In yestigations .. :::. 1.. I Congress Street,Suite 100 Boston A1.4 02114-2017 wiVW.11 im.gUV/llia Workers'Corlaipensation Insurance Affidavit:Builders/Col:>rtiractors/E lectricians/Plumbers Applicanj InLomgtion 1'leass Print Le 'bl Name(BusineWOrganizatioNindividual): SOLARC1TY CORD Address:3055 CLEARVIF-W WAY City/state/Zip:SAN MATEO,CA 94402 Photte#:889-7fr5-2459 Are you an employer?Check the appropriate box: Type of project(required): 1.® l am a employer with 5000 4. Q 1 am a general contractor and 1 emrployces(fail and/or pail-time), have hired lire sub-contractors 5 Nit'constntetion 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These subcontractors have 8. []Demolifron working for me in any capacity. employees and havo workers' 9. 0 Building addition [No workers'cnrrtp_insurance comp•insurance. requlred.) 5. 0 We arc a corporation and its I0.0 Electrical repairs or additions 3.❑ 1 am a hameowner doing all work officers have exercised their 11.❑Plumbing repairs or additions rnysel£ [No workers' comp, right of exemption per MGL 12-C]Roof repairs insurance required.)t c. 152,§1(4),and we have no employees.[No workers' 13.9 Other SOLAR//FV camp.insurance required.) *Any applicant that citccW box#1 must also rill out the section below showing their workers'compensation policy intbralaiion. t Horneouners who submit this affidavit Indleating they arc doing all wnrk and then hire outside contractors must submit a new affidavit indicating such. tConlactors that check this box must attached on additional sheet showbrp the name of the sub-contractors and state whether or not these entities have eraptoyces. irthesub-contractors have employees,they must provide their workers'cornp.policy nomher. �a� l am art e�trployer pleat its provitllpg►vorkars'eastnuilsalxon itisura�acc for my enipluyees. below fs the paikly marl,jnbslre lnfortnatfolt. Insurance Company Name: Zurich American Insurance Company Policy If or Self-ins.Lie.M._WC0182014-00_ __ Expiration Bate: 09/01/2016 .lob Site Address: CityistHte/zip: Attach a copy ofEhe workers'compensation policy declaration page(showing the poiiey number and expiration dime). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to(he imposition of criminal penalties ofa fine up to$1,500.00 and/or one-year hnpr•isonntent,as well as civil penalties in the farm ofa STOP WORK ORDER and a tine ofup to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to site Office of Investigations ofthe DIA for insurance coverage verification. I do Iterehy certo under the perins mil mroftles ofperjifrp lbal file hi arnrallon provNerl above Is true and correct. S1 UM: pholt Q/Jlcial me only. Do not write In!Iris area,to be completed 63,city or 161wr or(cfal. City or Town: Perinit/License 4 Issuing Authority(circle one): 1.Board or Health 2.Building Department 3.Cityfrown Clerk 4.Electrical Inspector S.Plumbing Inspector 6.Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Addres C Expiration Date t jj�V 978-875-1698 sigko&7 Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2017 Ad res Expiration Date Telephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.&1.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding[ ] Other Brief Description of Proposed Work: Install solar electric panels to roof of existing home,to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet sa. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Bethany Cunnigham as Owner of the subject property hereby authorize SOLARCITY to act on my be alf, in all atters relative to work authorized by this building permit application. 11/23/2015 Signature of Owner Date SOLARCITY CORP Kelly Strickland as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORP/ Kelly Strickland Print Na 11/23/2015 Signature of Own /Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. pepartment use Drily Cit of Northampton Status df Permit. '-IBuil ing Department Curb Cu00riveway.Paitttit 2 Main Street Sewer/ epticAva # l ji 2Q15 oom 100 Watermall Availability No ha pton, MA 01060 Two Sets of Structural.F�1a`rss b87- 240 Fax 413-587-1272 Plot(Slte Plans' per 1p1c o Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 41 AVIS CIRCLE Map Lot Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: BETHANY CUNNIGHAM 41 Avis Circle,Northampton MA 01062 Name Print) Current Mailing Address: 413-695-5472 l ,Y n Telephone Signature 2.2 Authorized Agent: SolarCity Corp/Kelly Strickland 604 Silver St Agawam MA 01001 Name rint) Current Mailing Address: �40A4 978-215-2367 Signature I Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building 4,000 (a)Building Permit Fee 2. Electrical 9,000 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total= 0 +2+3+4+5) 13,000 1 Check Number This Section For Official Use Only Building ermit Number: Date g Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2016-0727 APPLICANT"CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (888)765-2489(23 58) PROPERTY LOCATION 41 AVIS CIR MAP 22D PARCEL 110 001 ZONE URA000)/WSP(I00)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid F7 17 3 17 f Building Permit Filled out - Fee Paid Tyueof Construction• INSTALL ROOF MOUNTED 4.94 SOLAR ARRAY New Construction _Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included• Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORM ,0,TION PRESENTED: —AKFproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Gurb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Pen-nit from Elm Street Commission Permit DPW Storm Water Management Demolition D ay Sig ure of Bui ding Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning& Development for more information. 41 AVIS CIR BP-2016-0727 COMMONWEALTH OF MASSACHUSETTS N1at):I3lock: 22D- 110 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) CategorOLAR PANELS BUILDING PERMIT BP-2016-0727 Project # JS-2016-001218 Est. Cost: $13000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot size(sq. ft.): 22738.32 Owner: CUNNINGHAM BETHANY /Oni,i„ ulzAHOM/WSP I( E Applicant: SOLARCITY CORP AT. 41 AVIS CIR Applicant Address: Phone: Insurance: 604 SILVER ST (888) 765-2489 (2358) Workers Compensation AGAWAMMA01001 ISSUED ON:121112015 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL ROOF MOUNTED 4.94 SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: IZoi� h: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF A,\1� O F ITS Rt1LES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: 13uildlhn', 12/1/20150:00:00 $75.00 212 Main Street, Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner