24D-310 (5) String and Conduit Layout ti o� o N ----- 36'3" o w o 0 z g --Roof A(both sides) Z E Rake:6' w > O Ridge 6" z z d a Circuit 1 (13) ■ s o 0 Circuit 2 (12) ❑ Junction Box 0 End Cap 0 20'r' it a Trunk Cable it Exterior Conduit — 0 V s cn d � � G)W Hempstead,Michael-Northampton.Residence Electrical Review 84 Bancroft Rd.Northampton,MA 01060 Hopkinton,MA Office:Dana Beale Reviewed By:Melissa D.(610-680-0805) o ° Financing:Purchase o o tO O � 9 a (25)LG Neon 2 300w Panels with(25)M250 Inverters PV meter type:Enphase RGM w u O F Emu location:In the basement by the main service panel ¢ a Internet Connection:Bridge _ Main Electrical Panel:200 Amp Crouse-Hinds Utility:National Grid z Circuit Calculations: 25 inverters x 1/Inverter=25 Amps x 1.25=31.25 FLA. PV combiner with:(1)15 Amp,2 pole circuit breaker,(1)20 Amp,2 pole circuit breaker,(1)15 Amp,1 pole circuit breaker(for EMU) Interconnection Calculations:Main panel rated 200 Amp buss x 120%=240 Amp,minus main circuit breaker rating of 200 Amp=40 Amps for solar connection. Interconnection will be a circuit breaker connection in the existing 200 Amp electrical panel located in the basement.Install a 35 Amp,2 pole Eaton BR Classified circuit breaker for the solar connection in the existing 200 Amp panel.The circuit STRING& breaker for the solar connection MUST be installed at the far end of the panel away from the main circuit breaker.From the solar circuit breaker,bring the conduit outside and wire into a 60 Amp non-fused disconnect switch mounted on the CONDUIT LAYOUT adjacent exterior wall.From the disconnect switch,wire through the PV meter and then into the PV combiner panel.From the PV combiner panel,bring the conduit back into the basement.Once in the basement,transition to interior conduit then run conduit across the basement ceiling to get over to the west end of the house.At the west end of the house penetrate outside then run exterior conduit up the wall,wrap up over the eave and bring onto the roof.Once on the roof,run exterior conduit across the roof to the two junction boxes located under the two arrays,as shown in the drawing. All roof mounted conduit must be at least 1"above the roof surface and flash supported properly.There will be two circuits of inverters to the roof. PV-4 Electrical Diagram for Hempstead-7.5 kW DC Photovoltaic Solar Array National Grid Account Number-78223-46008 ti < to o < ^ N Calculation for PV Breaker PV Circuit Conductors PV Circuit Conductor o ,,, 0 cl Calculation for Main PV Breaker&Circuits PV Combiner Panel to PV Array Wire Calc p 1 Interconnection-Circuit Breaker Tie In Wire Calc ii 2 System Current= 25 1 = 25Amps Minimum A 10 AWG Minimum F 4 AWG -- z E WIRE SIZING CALCULATION z Design Amperage= 25 125% = 31.25 Amps WIRE SIZING CALCULATION w < O o x 2011/2014 NEC Article 310 (- Main Buss Rating= 200 x 120% = 240 Amps 2011/2014 NEC Article 310 ,,, z z Fuii Load Amperage_.._.......:13 Full Load Amperage...___.__:.25 '" - Existing Main Breaker = 200 Amps Source Voltage_. ..:240 Source Voltage ... _. :240 °p -o Max solar Breaker zoo (-) zoo = ao Amps Length of Run(Feet) 110 Length of Run(Feet)__. ...:30 Load Duty ontinuous ❑ Circuit#1= 13 x 1 x 125%= 16.25 Amps y Load Duty_. __. Continuous Conductor Application Application _..:Conductors in Raceway.Cable or Earth Conductor Application. ..... _:Conductors in Raceway,Cable or Earth Circuit#2= 12 x 1 x 125%= 15 Amps Conductor Ampeclty Table __.:NEC Table 310-15(B)(16) ConductorT pe..._.__..._...:THHN Copper Conductor Type tyTable__._:NEC Copper 310-15(8)(16) y Conductor Type _ ._ ... THHN Copper Conductor Location.. Dry/Damp Conductor Location.____ Dry/Damp Conductor Insulation Temperature:90'C Conductor Insulation Temperature.90'C Rooftop Installation:NEC 310,15(Bg3)(c) Ambient Temperature._ 26-30'C=78-86'F Distance Above Roof.._._..._. Above 13 mm to 90 mm[above 112 inch to 3 Terminal Temperature Rating -60'C x 112 inch) Circuit Type:Single Phase 3 Wire(2 phase conductors&neutral) Average Outside Temp 90 Deg,F 32.2 Deg,C City.of Circuit Current-Carrying Conductors..2 Temperature Adder ___ 40 Deg F 22 Deg C Conductor Requirement Adjusted Ambient Temperature_ 130 0 Deg F 542 Deg C Full Load Amps.ier ._ 1 25 Terminal Temperature Rating, 0'C Load Duty Multiplier_ 1 25 9 Ambient Temp.Multiplier..1.0 Circuit Type:Single Phase 3 Wire(2 phase conductors&neutral) City.of Circuit Current-Carrying Conductors 2 City Conductors Multiplier 1 0 Additional Current-Carrying Conductors d Required Conductor Ampacily 31.25 < ..... ......"-'"•""--------"' Terminal Requirement: � Total City Current-Carrying Conductors 6 Full Load Amps ....__.. 25 0 Conductor Requirement: Load Duty Multiplier _ 125 Full Load Amps_- 13.0 Load Duty Multiplier, 1.25 Required Te-r-m-i-n�al Awmpu acily:31.25 z m Ambient Temp-Multiplier. 1.32 Selected Conductor City.Conductors Multiplier 1.25 Conductor Ampacity.......-70.0 ----------------- Ambient Temp.Derate......1.0 Required Conductor Ampacily:26.81 .;.+ Terminal Requirement. Qty.Conductors Derate, t 0 Full Load Amps ..__. 13.0 Adjusted Ampacily 700 C�pp Load Duty Multiplier_ 1 25 SELECTED CONDUCTOR SIZE:4 Awg E✓1 LU t!1 Required Terminal Ampacity:16 25 2 x OhmslMilFt x Length x Amps 2 x 0 308 x 30 x 31.25 VD= "— go's Selected Conductor '""-_" '"""""""'"'-""-"-"°-"'—'"'-""=0 46 Conductor Am cit 30 0 Volt x t City Lo Wires per Phase 1000 x 1 aid � y Volts At Load Terminals.. ..:239.54 Ambient Temp..Derate.._. 0.76 Actual Percent Voltage Drop 0.19 City.Conductors Derate 0 8 Adjusted Ampacity~.^ . :18.24 Electrical Notes SELECTED CONDUCTOR SIZE:10 Awg 1)All equipment to be li:tad and labeled for it app8cetion. 2 x OhmslMilFt x Length x Amps 2 x 1.24 x 110 x 26.81 2)All conductors shell be copper,rated for 90C and wet environment,unless VD=--•--------------_____-__.._.__•..__..._.______=3 55 O otherwi.e noted. 1000 x City Wires per Phase 1000 x 1 0 Volts At Load Terminals....,. 236 45 ❑ o q 3)Working clearances around el newand existingelectrical equipment shell Actual Percent Voltage Drop, 1.48 p < omply with NEC110.26 a ~ 4)All wire terminations shall be appropriately labeled and readily visable. ❑ Z r w u O Z a G a m < a 5)Module grounding,lips to be installed between module fro..and module 'r = support rail,per grounding clip manufacturers instruction. _ 0o oc O z 6)Module Support rail to be bonded to continuous copper GEC vie WEEB lug per NEC 690.4(,). 7)If used PV power source breaker to be located at bottom of bus per NEC 690.64(B)f71. 8)AC combiner panels shell be labeled es"Inverter AC Combiner Panel". 9)listing agenoy name end number to be indicated an inverters and modules per ELECTRICAL NEC110.3(B) CALCULATIONS 10)PV power source breaker to be suitable for backfeed per NEC 690.64(B)(5). PV-3.1 Electrical Diagram for Hempstead-7.5 kW DC Photovoltaic Solar Array National Grid Account Number-78223-46008 � � o ¢ n O w o 0 Hempstead, Michael (Northampton) z E w Z 84 Bancroft Rd. U510DistnbuwnconrW;on G Z Z Northampton, MA 01060 o C' = C k" Soku Moline Total 25 Modules and inverters 240 Vat I Please DC wiring Iran M m e solar oan Non-iusW Disconnect e Mpl Switch rrwunted on Enpha Inv se Micro erter eMew wall Ground Huh Proection integrated within EATON Modet a Mvettet Madek M250-66211-522 PV Production pG222UR8 cc Max DC Van Ratlne: 48v Met. w hNa Power A 80 deerees C rAW Enplu se RGM 60 Amp 20O Amp oe T�hrs May 13 Pare is Mertes ' NtknMal AC Vahxe 2801208 13 aIAa12S%a 1615 on 20Amp Male Af Offtfl 1.0 Arm Circuit Breaker ' Two Ungrounded conductors and one Neural — - r circuit of inverters(Typ) '+ 20 mp ' ( ' W H is rnp (3)g4-TKHN.THWN-2 Copper ' 35 Amp / I (1)88-THHN-THWN.2 Copper Ground 11 t W ry m ' Installation of the 1"caWuk(110•)win have ( ) 1'PVC ConUUit or 1'Lipuktite Metal Conduit ) two cawhs,win conin of: 15 Amp I )� ' — — — — _ _ (4)810 THHN-THWN-2,phase caducto , ) GGOReceptack Wire Calt#2 (2)$10 THHN-THWN-2.rmurrah, ) _ _ for ErphM EMU plus(I)88 Ground _ _ _ _ _ _ ) Groundup Main �i rnK Array 12 PaneK/kwMers 1 125 Amp Main tug toadcta I gondmg Connectron 4-j en LM` 12 a1Aa12S%- 15 an 15 Amp Wire Calc#1 Iry Combix.panel ) 0�2 W M Circuit Breaker -- -- EATON Model 8 BRi16L125RP ) R6 Bare CU ) 200 Amp Buss Q LU 119 j� with circuit breaker listed below. ► — ' Crouse-Hinds 11)15 Amp.2-pole circuit breaker as shown above ) #6 Bare CU ) Panel Iry (1120 Ar p,2-pole circuit breaker as shown above I (1)15 Amp.1-pole circuit breakef to EMU I S/g ad'Ground 5(8.8'Ground Rod I Rod to A o � o F o V p o a w cc ¢ cL F d Z D O n w U d H a m ¢ ¢ 2 0 O Z � ELECTRICAL DIAGRAM PV-3 A Typical Section 7.5 kW DC Photovoltaic Solar Array ti � v o 5 un w o 0 This solar array is comprised of 25 LG NeON 2 300 Mono Black solar panels.The panels are mounted using the Unirac Solarmount solar j Q 0 mounting rail to the building's 2,4 rafter,spaced at 16 oc.Each solar panel is attached to an Enphase M250-60-2LL-S22 micro-inverteralso ¢ Z �t o mounted to the Unirac Solarmount rail directly beneath the panel, w Z j a a o F z z 1J� p1t'P V Y T H The solar panels produce DC power when struck by sunlight.The DC power is converted to 240 V AC power at the inverter.Micro-inverters 0 are connected in strings with a maximum number of 16 micro-inverters in each string. to This system will be grid-tied. H the solar panels produce more power than!,,,ad by the building,the excess power flows back into the utility grid through a net meter to be available for other power users. Vf Y All metal parts including solar panel frames,micro-inverters,and mounting rails are grounded using the manufacturer's recommended K grounding method and WEEK technology along with p6 AWG grounding wire. G The building was constructed in 1900. uu Et1 Q !db p > ry m C Panel Layout !\ PtJr.� Panel Dimensions 64.57 in x 39.37 in System Weight 1510 lbs �o Panel Weight 37.48 Ibz System Distributed Load 3.4 psf a`ti �,J E System Square Footage 441 sq ft RoofSUpport 2x4 rafter ,sta SE _ Racking Weight 463 Its Actual Point Load Max Spacing 4 i apo mil. W u Micro-Inverter Weigh[ 110 lbs Totalnumber of Roof Penetrations 89 ..pooxs Max Allowable Rail Overhang 16 in Members are Hem,Fir(North)allowing 235 lbs per inch thread depth Note 1:Use 5 116"x 4"Hex Head Stainless Steel Log Screws Variables Note 2:Roof Support Members are 2,4 rafter h 25 ft 3 it Pnet Downforce 12.1 psf Note 3:Unirac Solarmount Racking Note 4: H 28 it Wind Downforce 12.1 psf Pnet Uplift -14.6 psf Roof Pitch 38 degrees Wind Uplift -14.6 psf B 5.4 Load Combinations wMax 117 pif y 90 mph Kzt 1 D1 D2 D3 Uplift Max Span 4 f o to Snow Load 40 psf Exposure Category g Dead Load D 3.4 3.4 3.4 2.1 psf Actual Span 4 ft rj o 0 RoofZ.ne 3 A 1 Snow Load 5 40.0 0.0 30.0 0.0 psf Rd 4671bs < m ac E 441 I 1 DWL' Paler 0.0 12.1 9.1 -14.6 psf Ru 13516s o- Total Load P** 43.4 15.5 42.5 12.5 psf Required Thread Depth 0.57 in w . O Distrib TL 116.8 41.8 114.3 33.8 plf Actual Thread Depth 2.25 in N Q U d m a a *DWL:Design Wind Load = ca r **Absolute values are indicated for the calculated quantities of P-Uplift and w-Uplift Z Glossary of Terms for Load Calculations h Building Height A Adjustment Factor for height H Building Least Horizontal Roof Pitch Roof Pitch I Import ance Factor of for a single family residence Basic WindSpeed DESCRIPTION OF Snow Load Snow Load B Module length perpendicular to beams WORK&LOAD Roof Zone Roof Zone Rd Point Load-Maximum Downforce E Effective Roof Area Ru PointLoad-Uplift CALCULATIONS Roof Zone Setback Length Exposure B-Suburban single family dwelling Pnet Downforce Net Design Downforce Pressure Category pnet Uplift Net Design Uplift Pressure `' Kzt Topographic Factor n 1'1 V-2.1 Hempstead Residence Northampton 84 Bancroft Rd 210 Main St,Northampton,MA 01060 Northampton,MA 01060 5 a ° _-------- Roof A (both sides) o w o 0 -36' 3 � Z ,� Rake: 6" z E w System Ratings Ridge 6" w z z 7.5 kW DC Photovoltaic Solar Array w Y 6.25 kW AC Photovoltaic Solar Array = o 20' 1" Equipment Summary 25 LG NeON 2 300 Mono Black Modules '^ Y 25 Enphase M250-60-2LL-S22 Inverters Q E 89 Roof Attachments z Sheetlndex PV-1 Cover G PV-2.1 Description of Work and Load Calculations- A c PV-3 Electrical Diagram PV-3.1 Electrical Calculations PV-4 String and Conduit Layout PV-5 Equipment Ratings&Signage S v fu NEt1fu GlWLA Governing Codes 2014 National Electric Code 2003 International Building Code Underwriters Labratories(UL)Standards o 0 OSHA 29 CFR 1910.269 u o o Y w ASCE-7-10 O w C ry LL ry O Z n U 0 A a a U a m 4 _ K z z � City of Northampton COVER SHEET Building Department Plan Review 212 Main Street Northampton, MA 01060 PV-1 IRON RIDGE Roof Mounts Solar Mounting Made Simple Maximum Span Chart., trorl Standard Rait 1ronRidge tight Ratf Wind Speed Snow Loads 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 0 psf 10 psf 20 psf 30 psf 40 psf 90 mph 13.5' 12.5 10.5 10.0 9.0 8.5 7.5 8 7 6 5.5 5 100 mph 13.5 12.5 10.5 10.0 9.0 8.5 7.5 8 7 6 5.5 5 110 mph 13 12.5 10.5 10.0 9.0 8.5 7.5 7.6 7 6 5.5 5 120 mph 12 12 10.5 10.0 9.0 8.5 7.5 7 7 6 5.5 5 130 mph 11 11 10.5 10.0 9.0 8.5 7.5 6.5 6.5 6 5.5 5 140 mph 10 10 10 9.5 9.0 8.5 7.5 6 6 6 5.5 5 150 mph 9.6 9.5 9.5 9.5 8.5 8 7.5 5.5 5.5 5.5 5.5 5 Roof Zone 1, Flush Mount Only Building mean roof height=30' *For more information visit www.ironridge.com to Slope=6"/ft. Clearance between roof and rail:2" download certification letters, installation guides, Exposure category B End Cant Span:40%(adj.interior span) and to use our roof mount configuration software. Module length:77" Middle 1/3 span rail splice not permitted Attachments Clamps Adjustable L feet(4 pack kits) Panel Sizes 1.22"to 2.30" Adjustable tilt leg kits(5°to 45°) Mid clamps(require only Flush mount aluminum standoffs 1/4" between panels) (3",4",6",7") Mid clamps available in hex Tilt steel standoffs (4",6") or t-bolt All hardware stainless steel End Caps Wire Clips Protect against debris while providing a finished look for Accommodate up to eight 6mm panel both standard and light rails wires or an Enphase wire harness Experience-Designing/manufacturing On-line Resources Available: solar mounting products since 1996 Video Tutorials Single Source-Roof mounts, ballasted Product Configurators mounts, large arrays,and more; a Product Certifications solution for your specific application Installation Guides _ Customer Satisfaction-Customer Data Sheets " service and technical support to help Reseller Locator - you succeed Sales: 800-227-9523 www.IronRidge.com sales @ironridge.com 1435 Baechtel Road Willits,CA 95490 www.ironridge.com ©Copyright 2011 Iron Ridge,Inc.All rights reserved. DSRFM0411_1 ArAL RON RI DGE Roof Mounts Solar Mounting Made Simple } IronRidge Roof Mount System is a reliable,comprehensive,and feature rich photovoltaic mounting solution.Anchored by IronRidge Standard or IronRidge 1-1 -;tqLM11tV ,111d fastest SN'Stem for solar panel Light rails,our Roof Mount platform includes all of the components necessary for supporting virtually any commercial or residential roof mount installation, installers. OUrCLI-StO111CI-S regardless of roof type or pitch. appreciate the Professional with lronRldge rad profiles. IronRidge Standard Rails Less Material, Faster Install, Minimized Risk of Leaks Engineered for longer spans=fewer attachments&penetrations `-,f &:, ����k��i Other rails=Monger install time and greater risk of leaks r IronRidge Standard Rail Engineered profile allows for spans over 13' • a Cantilever can be 40%of span length •, Attractive structural design, ideal for residential and commercial applications 4 IronRidge Light Rail -- ® • Light,cost effective rail system supports i spans up to 8' ' ,. Cantilever can be 40%of span length u Splices(Internal) `ss • Can be installed at same location as an attachment Does not require additional attachments to support the splice www.ironridge.com ©Copyright 2011 IronRidge,Inc.All rights reserved. DSRFM0411_1 Enphasee M250 M icroi nverter//DATA INPUT DATA(DC) M250-60-2LL-S22/S23/S24 Recommended input power(STC) 210-300 W Maximum input DC voltage 48 V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A Max input current 9.8 A OUTPUT DATA (AC) @208 VAC @240 VAC Peak output power 250 W 250 W Rated(continuous)output power 240 W 240 W Nominal output current 1.15 A(A rms at nominal duration) 1.0 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range' 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 24(three phase) 16(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC 96.5% CEC weighted efficiency,208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted,reference EN50530) 99.4 % Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to+65°C Operating temperature range(internal) -40°C to+85°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 2.0 kg Cooling Natural convection-No fans Enclosure environmental rating Outdoor- NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35.Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547, FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, ( enphase° visit enphase.com e E N E R G Y ©2013 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. Enphase®Microinverters Enphase@M250 JAM Ism ............. 4 } fr;R .i§ }u f'�ius The Enphase" M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage' Cable, the Envoy' Communications Gateway", and Enlighten°, Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIABLE - Optimized for higher-power - No GEC needed for microinverter - 4th-generation product modules - No DC design or string calculation - More than 1 million hours of testing - Maximizes energy production required and 3 million units shipped - Minimizes impact of shading, - Easy installation with Engage - Industry-leading warranty, up to 25 dust, and debris Cable years e enphase® r L J E N E R G Y C us LG NeON-2 Black Mechanical Properties Electrical Properties(STC*) Cells 6 x 10 Module Type 300 W Cell Vendor LG MPP Voltage(Vmpp) 32.5 Cell Type IVonocrystalline/N-type MPP Current(Impp) 9.26 Cell Dimensions 156.75 x 156.75 mm/6 inches Open Circuit Voltage(Voc) 39.7 u of Busbar 12(Multi Wire Busbar) Short Circuit Current(Isc) 9.70 Dimensions(L x W x H) 1640 x 1000 x 40 mm Module Efficiency(%) 18.3 64.57 x 39.37 x 1.57 inch Operating Temperature(°C) -40-+90 Front Load 6000 Pa/125 psf 0 Maximum System Voltage(V) 1000 Rear Load 5400 Pa/113 psf io Maximum Series Fuse Rating(A) 20 Weight 17.0±0.5 kg/37.48 t 1.1 Ibs Power Tolerance(%) 0-+3 Connector Type MC4,MC4 Compatible,IP67 STC(Standardrest condition):irradiance 1000 W/my Module Temperature 25°C,Ann 1.5 Junction Box IP67with3BypassDiodes The nameplate power output is measured and determined byLG Electronics at its sale and absolute discretion. 'The rymcal change In module efficiency at 200 W/m'm relation to 1000 W/m'Is-3.0%. Length of Cables 2 x 1000 mm/2 x 39.37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum Electrical Properties(NOCT*) Module Type 300 W Certifications and Warranty Maximum Power(Pmax) 218 Certifications IEC 61215,IEC 61730-1/-2 MPP Voltage(Vmpp) 29.5 IEC 62716(Ammonia Test) MPP Current(Impp) 7.38 IEC 61701(Salt Mist Corrosion Test) Open Circuit Voltage(Voc) 36.5 ISO 9001 Short Circuit Current(Isc) 7.83 UL 1 703 *NOCT(Nominal Operating Ce,l Temperature.):Imadiance 800 W/m2,ambient-..emperawne 20'C,wind speed 1 m/s Module Fire Performance(USA) Type 2(UL 1703) Fire Rating(for CANADA) Class C(ULC/ORD C1703) Dimensions(mm/in) Product Warranty 12 years 0 Output Warranty of Pmax Linear warranty*1; "1)1 st year 98%.2)After 2nd year 0.6%p annual degradation,3)816%for 25 years Temperature Characteristics NOCT 46±3°C / 1 Pmpp -0.38%/°C ,"1 —. cos o—. oev,iz g .rnme „aefine Voc -0.28%/°C Isc 0.03%/°C s--*rt-- �.bw Characteristic Curves '��.,, are 1000W u 80OW a a0 500W 000 400W 600 ------- \ cabieb.yn a 200 200W - �gg V—g.ca le 2 or. 500 1.00 15.00 2000 2500 3000 35.00 40.00 4500 8 B a s 120 -- so Isc Pmax m 0 emperature(°C) 40 -21 o 25 so 's se j 'The distance between the center of the mounting/grounding holes. ® LG North America Solar Business Team Product specifications are subject to change without notice. LG Electronics U.S.A.Inc DS-N2-60-K-G-F-EN-50427 Life's Good 1000 Sylvan Ave,Englewaod Cliffs,NJ 07632 Copyright©201 5 LG Electronics.All rights reserved. Innovation fora Better Life Contact:Ig.solar@a Ige.com 01/04/2015 www.lgsolarusa.com ❑�J (8 LG Innovation for Life's Good Better LG NeON'2e/ack �• LG's new module,LG NeONTm 2 Black,adopts Cello technology.Cello technology replaces 3 busbars with C C APPROVEOPRODUCT 60 cell 12 thin wires to enhance power output and reliability. o�/E LG NeONT"2 Black demonstrates LG's efforts to increase customer's values beyond efficiency.It features enhanced Intertek M5"573 65Bd 61215 warranty,durability,performance under real environment, Phvafi-Moduis and aesthetic design suitable for roofs. Enhanced Performance Warranty •� High Power Output ,.....Z LG NeON'm 2 Black has an enhanced performance �i3iiii£35433� Compared with previous models,the LG NeONT"2 Black ®iiiiiiiiiisi® warranty.The annual degradation has fallen from-0.7%/yr �3433iiiiiiiii has been designed to significantly enhance its output UirUMU to-0.6%/yt Even after 25 years,the cell guarantees 2.4%p $"rrfsr*sss r efficiency,thereby making it efficient even in limited space. more output than the previous LG NeON'"modules. � Aesthetic Roof MAHA i® Outstanding Durability willil1 an illlill MHUR...... LG NeONT"^2 Black has been designed with aesthetics iiiiiis.....� With its newly reinforced frame design,LG has extended in mind;thinner wires that appear all black at a distance. eiaii i i s"s_aea the warranty of the LG Ne0NT 2 Black for an additional The product may increase the value of a property with - .. 2 years.Additionally,LG NeON'"^2 Black can endure its modern design. a front load up to 6000 Pa,and a rear load up to 5400 Pa. - .•. Better Performance on a Sunny Day err Double-Sided Cell Structure �3e€ii , ®iiiiii LG NeONT"2 Black now performs better on sunny days The rear of the cell used in LG NeONT"^2 Black will contribute thanks to its improved temperature coefficiency. -=°8------ to generation,just like the front,the light beam reflected = - - - from the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy busiress as its future growth engine.We embarked on a solar energy source research program in 1985,supported by LG Group's rich experience in semi-conductor,LCD,chemistry,and materials industry.We successfully released the first Mono X'"series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter,In 2013,LG NeONTM'(previously known as Mono X'"'NeON)won"Intersolar Award";which proved LG is the leader of innovation in the industry. The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 1 Congress Street, Suite 100 - Boston,MA 02114-2017 s�• www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Directenergysolar/AstrumSolar _ Address: 15 Ave E City/State/Zip: Hopkinton, MA 01748 Phone#: 1-800-903-6130 Are you an employer? Check the appropriate box: Type of project(required): 1.0 I am a employer with 15 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. F-1 New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.* required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152,§1(4),and we have no solar employees. [No workers' 13.AN Other comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. +Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Policy#or Self-ins. Lic.#:WC595396901 Expiration Date: 1/1/16 Job Site Address: 84 Bancroft Rd, City/State/Zip:Northampton, MA 01060 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under tth pains ndpen es of perj ry that the information provided above is true and correct. Si ature_ --\G" Date: Phone#: 508-614-0550 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: ;lam a::.,:gin a/ o1',_.1&.,j,,rXu. Office of Consumer Affairs&Business Regulation License or registration valid for individul use only ;!'HOME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: 1 Office of Consumer Affairs and Business Regulation Y Registration: 168228 Type: 10 Park Plaza-Suite 5170 Expiration: 1/19/2017 Supplement Card Boston,MA 02116 ASTRUM SOLAR INC. ROBERT ACEVEDO r 8955 HENKELS LANE STE 508 ANNAPOLIS,MD 20701 Undersecretary Not va id without signature Massachusetts -Department of Public Safety Board of Building Regulations and Standards Cinitruction License: CS-057898 ROBERT W ACE ' 64 MAPLE ST IF y FRANKLIN MA 712 Expiration Commissioner 08115/2017 i Mike Hempstead Residence Solar Installation 84 Bancroft Road Northampton MA Gravity Loading: Roof A—adequate to support the proposed solar panels It is our understanding that the panels will be installed using Unirac rail with L-feet(or equal)at approximately 48 inches on center(e.g. every two to three rafters). The leveling feet will be fastened directly into the existing joists with 5/16" diameter lag screws with a minimum embedment of 2.5". In addition, it is important that the leveling feet support locations be staggered between adjacent panels so that no single rafter supports more load than under the existing conditions. Wind Loading: Based on our calculations,the net wind loads imposed on the roof framing with an attachment spacing as indicated above will be less than the current loading on the roof framing. In addition, provided that the leveling feet are attached to the roof framing members in atypical staggered fashion,the overall wind loading imposed on the structure and the individual framing members will not be impacted to any great extent. If you have any questions regarding this matter,please feel free to contact my office at 609-489-5511. We appreciate the opportunity to assist you with this evaluation. Sincerely, MPP Engineers, LLC Krishna J Allam E.I.T. N OF�1gS ASIil G N C' a -i NO. 35 CO NAL Ashutosh Patel,P.E. MA Prof. Eng. Lic.No. 48235 Mike Hempstead Residence Solar Installation 84 Bancroft Road Northampton MA shingles. The pertinent data is listed below: Roof—A (25 Panels Total): Rafters: TRUE 2"x 4"(#2 Spruce-Pine Fir Assumed) Spacing: 16"O.C. Roof Slope: 38 Degrees Horizontal Projected Length of Rafter (Horizontal Projection): 14.00 feet with a interior load bearing wall at 6' -0"from the ridge Ceiling Joists: Present Collar Ties: NOT Present Roof Sheathing: Wood Boards and plywood sheathing Condition of Framing: Good Roof Covering: Asphalt Shingles Ground Snow Load,Pg: 40 PSF from Table R301.2 (5)of Massachusetts Residential Code Importance Factor,I: 1.0 Exposure Factor,Cc: 1.0(Conservatively taken as Partially Exposed) Thermal Factor, Ct: 1.1 with Panels (Cold Roof) 1.0 existing condition (Warm Roof) Design Snow Loads On sloped roof: 22.40 PSF(Existing—Unobstructed Warm Roof) 16.43 PSF (New—Slippery Surface on Cold Roof) Wind Speed: 90 MPH from Table R301.2 (4)of Massachusetts Residential Code Exposure B Analysis Results: General Considerations ➢ The proposed solar panels consist of solar panels which impose a total weight of approximately 2.5 to 3 pounds per square foot(PSF) on the roof surface. From a practical standpoint,the International Residential Code allows up to 2 roof coverings on a residential dwelling. Each layer of roofing imposes a net load of about 2.5 to 3.0 PSF on the roof. From this perspective, since the existing roof has only a single layer of shingles,a second layer is allowed to be added by the code without analysis.This 2nd layer of shingles essentially weighs the same as the proposed solar panels. ➢ Materials such as metal roofs or solar panels are considered slippery surfaces. Since the solar panels are mounted slightly above the roof line, it would be conservative to consider a thermal factor Ct of I.1,treating the panel surface as a cold roof rather than a warm roof. Based on the roof slope and considering it as a slippery surface,the snow load is reduced by 27% compared with the snow loading directly on the existing shingled roof surface. This reduction equates to 5.97 PSF which essentially offsets the weight of the solar panels. N.. ■■■ ■■■u■' ■ ■uZ N. M. n■ ■■ty on n■A STRUCTURAL ENGINeERS M F=' F=0 November 14, 2015 Revised November 30,2015 Town of Northampton Building Department 212 Main Street#100 Northampton MA 01060 RE: Mike Hempstead Residence Solar Installation SO— 151015-50 84 Bancroft Road Northampton MA Structural Assessment of Roof Framing MPP Project No: 15-3480 Dear Mr. Taboubi: Pursuant to your request,MPP Engineers has performed a limited structural evaluation of the roof framing at the above referenced site to determine if the roof has adequate capacity to support the proposed solar panels. Our analysis was based on the framing information and configurations provided by Direct Energy Solar. It is our understanding that the structural components of the existing roof framing are in fair condition. It is further understood that all existing connections between the various roof framing members, including ceiling joists and rafters are adequate to resist the current loading conditions and behave in the manner that a typical rafter and ceiling tie system is intended to behave prior to installation of the solar panels. Results Roof A—adequate to support the proposed solar panels Structural Data and Code Information Our analysis was performed in accordance with the requirements of the 780 CMR 51.00: Massachusetts Residential Code which has adopted the 2009 International Residential Code with Massachusetts amendments. Per Table R301.2 (1),the ground snow load to be used for each town is in accordance with Table R301.2(5). Similarly,the wind speed for each town is in accordance with Table R301.2(4). The roof framing was analyzed in accordance with Section R104.11 of the of the 2009 International Residential Code which allows for alternate approved design such as using the ASCE 7 code for determining actual snow loads on roofs(e.g. deriving flat or sloped roof snow loads from the specified ground snow load referenced in Table R301.2(5)). Wood members were analyzed and designed in accordance with the NDS 2005. The roof area for the solar panels of this residence is framed in a gable configuration with conventional 2x roof rafters. The existing roof structure is in good condition and is assumed to have one layer of asphalt MPP Engineers, LLC 1 34 South Main Street, Suite D I Allentown,NJ 08501 609-489-5511 (office) I www.mppenvineers.com 1 609-489-5916 (fax) City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: 84 Bancroft Rd, Northampton, MA 01060 The debris will be transported by: Direct Energy solar The debris will be received by: Direct Energy sour Building permit number: Name of Permit Applicant Robert Acevedo Date Signature of Permit Applicant A`°R°® CERTIFICATE OF LIABILITY INSURANCE page 1 of 1 DATE 30/20 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Willis of Texas, Inc. PHONE FAX c/o 26 Century Blvd. 877-945-7378 888-467-2378 P.O. Box 305191 E-MAIL certificates@willis.com Nashville, TN 37230-5191 INSURER(S)AFFORDINGOOVERAGE NAIC# INSURERA:ACE American Insurance Company 22667-302 INSURED Direct Energy and its majority owned INSURERB: Zurich American Insurance Company 16535-305 subsidiaries and affiliates including INSURERC:American Zurich Insurance Company 16535-306 Direct Energy Solar, Inc. 8955 Henkels Lane, Suite 508 INSURER D: Annapolis Junction, MD 20701 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:23860117 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPEOFINSURANCE DDL SUB pOLICYNUMBER POLICY EFF POLICY EXP LIMITS ITR A X COMMERCIAL GENERAL LIABILITY XSLG27341226 1/1/2015 1/1/2016 EACHOCCURRENCE $ 1,000,000 ppAAWREETpt RoccueCLAIMS-MADE X OCCUR rnce) $ 100,000 X SIR: $100,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERALAGGREGATE $ 1,000,000 POLICY PRO- 11 JECT LOC PRODUCTS-COMP/OP AGG $ 1,000,000 OTHER: $ B AUTOMOBILE LIABILITY BAP595396601 1/1/2015 1/1/2016 COMBINED SINGLE LIMIT (Ea accident) $ 1,000,000 X ANY AUTO BODILY INJURY(Perperson) $ ALLOWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS HIR DAUTOS NON-OWNED P PER YDAMAGE AUTOS ( ) $ A X UMBRELLALIAB X OCCUR XOOG25703728 1/1/2015 1/1/2016 EACH OCCURRENCE $ 2,0 0 000 EXCESS LIAB CLAIMS-MADE AGGREGATE $ 2,000,000 DED I RETENTION$ $ C WORKERS COMPENSATION WC595396901 1/1/2015 1/1/2016 X I PER oTH- AND EMPLOYERS'LIABILITY B ANY PROPRIETOR/PARTNER/EXECUTIVE NIA WC595397301 1/1/2015 1/1/2016 E.L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? S Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 tyes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additonal Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE City of Northampton 212 Main Street Northampton, MA 01060 Coll:4809762 Tpl:1942956 Cert:23860117 ©198 2014 ACORD CORPORATION.All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:Robert Acevedo 57898 License Number 64 Maple Street, Franklin, MA 02038 8/15/17 Address Expiration Date 508-614-0550 Signature Telephone 9.R e Im rovement Contractor. Not Applicable ❑ irect Energy Solar Robert Acevedo 168228 om an Name Registration Number 8955 Henkels Lane,Anna olis, MD 20701 1/19/17 Address Expiration Date Telephone 508-614-0550 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ® No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the buildine permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alterations) ❑ Roofing ❑ Or Doors ED Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [❑ Siding[0] Other[ Brief Description of Proposed Work: Install a rooftop solar array laaaed into existing rafters -- 5 �-LT 3 ' a.', eAs Alteration of existing bedroom Yes V No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes _ No Plans Attached Roll -Sheet 6a.If New house and or addition to existing housing, complete the following: a. Use of building :One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Mike Hempstead as Owner of the subject property hereby authorize Direct Energy Solar / Robert Acevedo to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date Robert Acevedo as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Robert Acevedo Print Na 1 Signature of Owner/Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage u Setbacks Front Side L: _ R: L: R: ._ Rear Building Height Bldg.Square Footage Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Findin ver been issued for/on the site? NO © DONT KNOW YES Q IF YES, date issued: IF YES: Was the permit recorded at the Regis I of Deeds? NO 0 DONT KNOW YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO e( DONT KNOW 0 YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained O , Date Issued: C. Do any signs exist on the property? YES ® NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES ® NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,exca ation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ® NO (2 IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Department use only - ---- City of Northampton Status'of Permit: Building Department Curb Cut/Driveway Pe- DE� ' 212 Main Street Sewer/Septic Availability Room 100 WaterEWelt Avallabil!tY loq,hampton, MA 01060 Two sets of structowal'Pfana'` 413-$87-1240 Fax 413-587-1272 PlotFS te'Plaas . Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office Map Lot Unit /� Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Mike Hempstead 84 Bancroft Rd, Northampton, MA 01060 Name(Print) Current Mailing Address: 413-582-0476 Telephone Signature 2.2 Authorized Aaent: Robert Acevedo 15 Avenue E Hopkinton, MA 01748 Name(Print Current Mailing Address: 508-614-0550 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building 26500.00 (a)Building Permit Fee 2. Electrical 2500.00 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) 29000.00 Check Number This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date 3�� File#BP-2016-0757 APPLICANT/CONTACT PERSON ASTRUM SOLAR ADDRESS/PHONE 15 AVENUE E HOPKINTON01748 (508)259-2387 PROPERTY LOCATION 84 BANCROFT RD MAP 24D PARCEL 310 001 ZONE URA000)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE 70NING FORM FILLED OUT Fee Paid T 74-7 Building Permit Filled out - Fee Paid Typeof Construction: INSTALL ROOF MOUNTED SOLAR ARRAY �j✓ New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 057898 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management nolition Delay ur Build g Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning& Development for more information. 84 BANCROFT RD BP-2016-0757 GIS#: COMMONWEALTH OF MASSACHUSETTS M�jj)-Bloci<: 24D-3 10 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-0757 beet JS-2016-001258 Lst. Cost: S29000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: ASTRUM SOLAR 057898 Lot Size(sq. ft.): 8319.96 Owner: HEMPSTEAD MICHAEL _zoi,-i i,�__uRA(I00)/ Applicant: ASTRUM SOLAR AT. 84 BANCROFT RD Applicant Address: Phone: Insurance: 15 AVENUE E (508) 259-2387 WC HOPKINTONMA01748 ISSUED ON:121312015 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 7.5 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: lz ugh: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Buildin<-' 12/3/2015 0:00:00 $75.00 212 Main Street, Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner