Loading...
11-001 (20) 14 ,_ Job Number: 1 Report Description:VH MOST REMOTE 2ND FLOOR Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Len th ]indicatedAO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow 9pm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop BFP Backfiow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot MS Miscellaneous Friction Loss psi/Foot C(Iq Co slRun OR Outriqqer HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pn Normal pressure at a point in a pipe DPV Dry Pipe Valve ST Stand Pipe Pf Pressure loss due to friction between points E 90°Elbow UG Underground Pe Pressure due to elevation difference betweeEE 45°Elbow points Eel 11'/ Elbow Pv Velocity pressure at a point in a pipe Ee2 22'/z°Elbow f Flow Device fd Flex Drop FDC Fire Department Connectio fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow fig Flange FN Floating Node fT FireLock(TM)Tee q Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve T.R ARNOLD&ASSOCIATES,INC. PO Pipe Outlet P.O.Box 1081 PRV Pressure Reducing Valve PrV Pressure Relief Valve Elkhart,IN 46514 red Reducer/Adapter State(s) Massachusetts S Supply Accredited Evaluation and sCV Swing Check Valve Inspection Agency Spr Sprinkler St Strainer This document is certified as being in conformance T Tee Flow Turn 90° with State Building Codes. Tr Tee Run Date Jul 31,2015 U Union Approval of this document does not authorize or approve WirF Wirsbo any omission or deviation from the requirements of WMV Water Meter Valve a licable State Laws. Z Cap SYSTEM DEMAND = 198 . 50GPM @ 66 . 565PSI � DOMESTIC DEMAND= 30GPM 6 SAFETY MARGIN = 18 . 104PSI (21 . 40) NOTE: NODE 6 IS FOR DOMESTIC D ©M.E.P.CAD, Inc. ?AAutoSPRINK®VR1l vll.0.30.0 6/5/2015 9:15:03AM Page 7 Job Number: 1 Report Description:VH MOST REMOTE 2ND FLOOR Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Len th &•••••Route/ • ••• BL 1 1010 16 nr. 5AI 150 0.04527 0'-2" Pf 0.234 101 30'-0" 16.05 4.4 13.300 Sprinkler, 5'-0" Pe 1 30'-0" 13.534 T(5'-0") 5'-2" Pv 1,1010 12 0,C) 10-81 150 0.1 3 00 13'-10" Pf 5.364 1 30'-0" 16.05 13.534 Flow(q)from Route 2 19'-0" Pe 4.335 2 20'-0" 23.234 2E(7'-O"),T(5'-0") 32'-10"Pv BL 1 5980 09 5.13 150 2'-8" Pf 0.098 2 20'-0" 23.234 1'-0" Pe 3 20'-0" 23.332 Tr(1'-0") 3'-8" Pv R1 1 5980 9056 809 150 0.061669 T-11" Pf 0.549 3 20'-0" 18.47 23.332 Flow(q)from Route 4 1'-0" Pe 4 20'-0" 23.881 Tr(1'-0") 8'-11" Pv RL 1 ! SO 1096 150 0.108136 98'-6" Pf 22.872 4 20'-0" 17.93 23.881 Flow(q)from Route 3 113'-0" Pe 5.717 5 6'-10" 52.470 11 E(9'-O"),6Tr(1'-O"),T(8'-0") 211'-6" Pv QJ27321 1'-6" Pf 0.505 5 6'-10" 52.470 2'-6" Pe 6 6'-10" 52.975 LtE(2'-6"),FN 4'-0" Pv BL 21570 98.50 8.65 120 0.07424 4'-4" Pf 0.594 6 6-10" 30.00 52.975 3'-8" Pe 1.869 7 2'-6" 55.438 2f(-0.000),UE(3'-8") 8'-0" Pv RL 20670 q8 0.091369 1'-5" Pf 5.133 7 2'-6" 55.438 Pe 8 2'-6" 60.571 BFP(-5.000) 1'-5" Pv BL 19590 98 50 10.48 150 0.07 5 6 50'-5" Pf 4.781 8 2'-6" 60.571 10'-6" Pe 3.685 9 -6-0" 69.036 3E(3'-6") 60'-11" Pv UG 4-2200 9850 2-26 140 0.002125 485-0" Pf 1.130 9 -6'-0" 69.036 46'-10" Pe 10 -6-0" 70.167 2EE(6'-8"),2E(16'-9") 531'-10" Pv LIG 62800 98 SO 1 02 140 0.000307 187'-10" Pf 0.064 10 -6-0" 70.167 22'-1" Pe 11 -6-0" 70.231 E(22'-1") 209'-10" Pv 8.,;q00 98 00075 31'-0" Pf 0.005 11 -6'-0" 70.231 30'-6" Pe 12 -6'-0" 70.236 E(30'-6") 61'-6" Pv tic, 62800 9850 1-02 140 0.000307 25'-5" Pf 0.015 12 -6-0" 70.236 22'-1" Pe -3.685 13 2'-6" 66.565 E(22'-1"),S 47'-6" Pv 1013.00 Hose Allowance At Source 13 198.50 w..... oute2••••• RL 1.1010 1605 5.41 0.045271 0'-2" Pf 0.234 102 30'-0" 16.05 4.4 13.300 Sprinkler, 5'-0" Pe 1 30'-0" 13.534 T(5'-0") 5'-2" Pv w••• •Route3••••• RI 1 1010 1793 6-04 150 0.055616 26'-8" Pf 2.931 103 30'-0" 17.93 4.4 16.614 Sprinkler, 26'-0" Pe 4.335 4 20'-0" 23.881 3E(T-0"),7(5'-0") 52'-8" Pv tom•••••Route 4••••• BI 1,1010 1847 6.22 150 - 0.058736 12'-6" Pf 1.734 104 29'-2" 18.47 4.4 17.624 Sprinkler, 17'-0" Pe 3.974 3 20'-0" 23.332 2T(5'-O"),E(7'-0") 29'-6" Pv Actual Inside Diameter \4 87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter l =Factor Multiplying Facto( 0.713 1.16 1.33 1.51 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This dmes crtd as eing n mlemn SYSTEM DEMAND 198 . 50GPM @ 66 . 565PS -1h a"dd,ng cedes. DOMESTIC DEMAND= 30GPM Date Jul 31,2015 ,pp lhsd--ne---e pj- SAFETY MARGIN = 18 . 104PSI (21 .40) anY em,ssan o,deviatim,nm,�.,�,,em",s bade Stake taws. ( © M.E.P.CAD, Inc. jjAUt0SPRINK0VRl1 01.0.30.0 6/5/2015 9:15:03AM Pape 6 Job Number:1 Re ort Description:VH MOST REMOTE 2ND FLOOR Node7 Elevation Foot Fittings Pressure(psi) Dischar e m q136'-10" UE 2'-6" FN 52.975 30.00 DOMESTIC DEMAND 2'-6" S 66.565 96.50 30'-0" S r-13.300 13.300 16.05 30'-0" S r-13.300 13.300 16.05 30'-0" S r-16.614 16.614 17.93 104 29'-2" S r-17.624 17.624 18.47 1 30'-0" T(6-0") 13.534 2 20'-0" T '-0" 23.234 3 20'-0" T(5'-O"),Tr 1'-0" 23.332 q 20'-0" T(6-01,Tr 1'-0" 23.881 5 6-10" 52.470 7 2'-6" LtE 3'-8" 55.438 8 2'-6" 6FP-5.000 60.571 9 -6'-0" E 3'-6" 69.036 10 -6'-0" E 16'-9" 70.167 11 6'-0" E 22'-1" 70.231 12 -6-0" EC-30'-B" 70.236 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elhhar(,IN 46514 State(s)Massachusetts Accredited Evaluation and Inspection Agency This document is rnniWd as being in conformance with St le Butltling Codes. Date Jul 31,2015 Approval of this document due1 authorize or approve any omission or tleviation Uorn the ruluiraments of ap,ranie state taw,. NDEMAND = 198 . 50GPM @ 66 . 565PS IC DEMAND= 30GPM MARGIN = 18 . 104PSI (21 .40) 6f512015 9:14:58AM Pages fg,0M.E.P.GAD.Inc. 4jAtjtoSPRINK0VR1101.0.30.0 a� Job Number:1 Ile Report Description:VH MOST REMOTE 2ND FLOOR Actual Flow Minimum Flow K-Factor Pressure Device m m K (psi) Floating Node 6 30.00 30.00 0 52.975 DOMESTIC WATER FLOW ;> Sprinkler 101 16.05 16.05 4.4 13.300 Sprinkler 102 16.05 16.05 4.4 13.300 Sprinkler 103 17.93 16.05 4.4 16.614 Sprinkler 104 18.47 16.05 4.4 17.624 Most Demandinq Sprinkler Data T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this dorument does not authorize or approve any omission or deviation from the requirements of applicable State Laws. SYSTEM DEMAND = 198 . 50GPM @ 66 . 565PSI DOMESTIC DEMAND= 30GPM SAFETY MARGIN = 18 . 104PSI (21 .40) 6/5 CC1, M.E.PCAD,Inc. -t AAOSPRINKOVR11 v11.0..30.0 12015 9:14:53AM Page 4 _.. 7A Job Number: 1 Report Description:VH MOST REMOTE 2ND FLOOR Hydrant at Node 13 ,00 Static Pressure 85.000 80 1384.00 73.000 70 8.50 66.565 198.50 with hose streams 60 y a ti 50 m CL` 40 S stem demand curve 30 20 to MAND = 198 . 50GPM @ 66 . 565PSI 6 DOMESTIC DEMAND= 30GPM SAFETY MARGIN = 18 . 104PSI (21 .40) 0 3000 0w 600 900 1200 1500 law 2100 2400 2700 Water flow,gpm HydrauBc Graph Hydrant at Node 13 I.R.A13NOIII&ASSOCIATES Static:Pressure P.O.Be.1081 85.000 Elkhart.IN 4014 _ Residual:Pressure S[ate(s) Massachusetts 73.000 @ 1384.00 Accredited Evaluation and Available P,essure.Tme of Test Inspection Agency 84.670 @ 198.50 This J�--1rn is—irw IS wing in — with State.buOding Cwes. System Demand 66.565 @ 98.50 Date Jul 31,zots system Demand(1-1 ling H AP----et Seerce) any unsv a eehelim Fran me iequi rcc d 66.565 @ 198.50 �an 5t le taw,. ©M.E.P.GAD, Inc. ?D AutoSPRINKO VR11 01.0.30.0 6/5/2015 9:14:49AM Paqe 3 Job Number: 1 Report Description:VH MOST REMOTE 2ND FLOOR Jbk? d w ~ ,, .. r .» ,__..., .. n f=:� ref'° .y 4_ M Job Number Desgn Engineer 1 Nathan Hart Job Name: State CerGficaliduA apse Number Housing for Veterans Address 1 AHJ 421 North Main Street Town Fire Dept. Address 2 Job Sile/9uikling Leeds, Massacusefts Leeds Fire Chief Address 3 Drawing Name 01053 2nd fl upper level _. . 2,77 ,. 7.e, Meet Demanding Sprinkler Data Occupancy Job SON, 4.4 K-Factor 16.05 at 13.300 Light Hazard Hose Allowance At Source Density Area o(Appfrcallon 100.00 0.100gpm/ft2 1500.00112(Actual 428.18ft2) Addi5onal Hose Supoes Number Of Spdnklots Calculated Coverage Per Sprinkler Node Flow,Q m) 4 256,00ft2 AutoPeak Rasu s Pressure For Roonote Area(s)Adjacent To Most Remote Area 6(DOMESTIC DEMAND) 30 GPM Left:66.565 Right:66,565 LEMAND = 198 . 50GPM @ 66 . 565PSI DEMAND= 30GPM ARGIN = 18 . 1 4 S (2 .40 Total He.Skes, 100.00 System Flow Demand TIA Water Required(Including Hose Allowance) 98.50 198.50 Maximum Pressure Unbalanco In Loops 0.000 Maximum Velocity Above Ground 10.96 between nodes 5 and 4 Maximum Velocity Under Ground 2.26 between nodes 10 and 9 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 982.05gal Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name m si (psi) @ m (psi) @ m (psi) (psi) 13 Hydrant 100. 85.000 73.000 1384.00 84.670 198.50 66.565 18.104 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency 1Tia d+KUme,e5cert(raas being In-of mare wan sma auilning codes. Date Jul 31,2015 AppmvalWtwrs tlwum,mt does amhoriee o,approve any rxnasrcm a deviation l+om Ne req,nr«menu N caw-stare laws_ Contractor Number Contact Name Contact TO. 22 _ Nathan Hart PM Name of Contractor; Phone Extension RBM Guardian Fire Protection Inc. 518-463-4340 Address 1 FAX 8 Enterprise Drive Address 2 E-mall _-- Albany, New York 12205 nathan @rbm-guardian.com Address 3 Web-Site @ M.E.P.CAD, Inc. jjAutoSPRINK@VR11 01.0.30.0 6/5/2015 9:14:43AM Page 2 Job Number:1 LiteRe or,�Oew r Lion.VH MOST REMOTE 2ND FLOOR Jo4:-rnhef :- Dealtin Enalnper 1 Nathan Hart Jobfame. ...»........ ._._.�.._..- ..... ..,....»._...._..._..:..e_...P,a.:....,, ._..W _.:. f __�._. ,.,.. Housing for Veterans- 518463-4340 �y Atltlross i - _,Wis 5::€Caianl.ro-sse�m,4tr -- A21 North Main Street Leeds,Massacusetts Town Fire Dept. 01053 Leeds Fire Chief .. .. 0100gpmfftz _ 500.00ft'(Actual 428.18ft2) M.f Oemaede 2 Sponkwr Date rbse steam, 4.4 K-Factor 16.05 at 13.300 100:00 �,.Of& CwaagdlPa Spieklar twrrAer of SVanlders l:akWabG 25600ft= 4 ............... �__�_._.���: Syelem FioNUentand 66.565 j 98.50 Toiol Dsmaro Presavo itasua 19$.50 Ca?66.565 +18.104(21.4%) Node Norte Fbw(apm)Hose Flow(gnm Sta i si)Residual(usr ldenti r Pressure(osi)7 K-Factor(K) Fbw/ovml 13 Hydrant 1384.00 100.00 85.000 73.000 OF T.R ARNOLD&ASSOI FATES,INC. Ijg S* P.O.Box 1011 �p�TINyt ttr�yq Elkh Massa 9 14 ,+^ X s�a;7;�)}p#y Fro �: State(s) Massach setts { E Vi A—edited Evalual on and t—p- -- Inspec[o Age y d— S— Date m e�o t�J Wa aeis m msmeq t o, 1 zo-h ylu vs L DEMAND i9$.50GPM 66.565P . ORAL M G ie e m i a a anpsapW ny w e MARGIN = 18 .104PSI (21 . 4%) 77 7 rant a#: f 4 250- ' 100 ww. _ 1 , --static Pressure 85.000: _ _ -. . 1364.00 73.000 70 Std' 68.`^ 1 198.50 with hose streams o a 40 sSy tem demand cum._ { 30 20 _ kp%Wl 1800 2100 240' 2700 3000 Water flow,gpm 0 M E.P.CAD,Inc. AutoSPRINKO VR11 v1 D 30.0 615!2015 9:14:34AM Page 1 T.R ARNOLD&ASSOCIATES,INC. P.O.Be.1081 Elkhart,IN 46514 state(s) Massachusetts Accredited Evaluation and 1—pect on gency C 41 x gNONNI!to ea � ' �`.. 10 FUNCTION: Designed for use in pipe hanger assembly. THIZ I�DED STUDS MATERIAL: Low carbon steel FINISH: Plain ORDERING: Specify rod size,length(B)and figure number. / Max.Rec. B Rod Load/Ibs. � Wt.Per Size ° Inch/Ibs. 5 75140 3/e x B 7330 0 540 .02 Available in stainless \ 112 x B 1350 1010 ! ,04 steel.To order,specify 516 x B 1810 1610 ( 07 304 or 316 and add suffix SS to figure '/4 x B 2710 2420 _11 number. '/6 x B 3770 3360 .14 Price on request. KJ FUNCTION: Designed for use in pipe hanger assembly. F�g:15&15L M1�CH E 'r.,l EA D MATERIAL: Low carbon steel I31� �sElt ROD FINISH: Plain Fig.15 RIGHT-HAND THREADS ORDERING: Specify rod size,length(B)and figure number- Fig.15L RIGHT-AND LEFT-HAND THREADS Max.Rec. ` Available \ Rod Thread Load/lbs:' Wt.Per in s steel. /\ Size Length 650-F 750°F Inch/tbs. To or ,r, 1'0 order, �_ cC specify 304 B 3/6 x B 21/2 730 ( 540 .03 or 316 and '/z x B 2% 1350 1010 .06 add suffix SS to \ C/\ 5/;x B 2'/2 1810 i 1610 .09 numbegrllre 3/4 x B 3 2710 2420 .13 Price on '/6 x B 3'/z 3770 3360 ,17 request. 1 x B 4 4960 I 4420 .22 rI FUNCTION: Useful in applications where stud lengths cannot be predetermined. DU MATERIAL: Low carbon steel END RO - ORDERING: Specify rod sire,length and figure number. Fig.20* PLAIN Fig.21 ELECTRO-GALVANIZED Packaging Max.Rec. Rod Feet Per Bundle Laad/lbs, Wt.Per Size 6 ft. 10 ft. 12 ft. 650°F 750°F Footllbs. 1/4-20 300 500 600 240 210 .12 3/6-16 i 150 200 240 610 540 1 .29 *Available in %-13 72 120 144 1130 1010 .54 stainless steel.To 5/0-11 48 80 96 1810 1610 .83 order,specif} 304 or 316 and add suffix SS to 3/4-10 30 50 60 2710 2420 1.25 figure number. 7/8-9 24 40 48 3770 3360 1.65 Price on request. 1-8 12 20 24 4960 4420 2.25 12 PHD Manufacturing, Inc. FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The knurled insert nut that allows a vertical adjustment after installation,is Vi .141 &141F topped to NFPA reduced rod size standards. Fig.141 F has a layer of felt F� �4 which separates the pipe from the hanger to red um vibration and sound. APPROVALS: Underwriters•'Laboratories listed and Factory;Mutual approved Fig.147 %i'to 8"sizes only.Complies with Federal Specification A-A-1192A(Type 10),Manufacturers'Standardization Society SP-69(Type 10)and NFP Fig.141 PRE-GALVANIZED standards for reduced rod sizes. Fig.141F PRE-GALVANIZED ORDERING: Specify pipe size and figure number. WITH FELT LINING SizRod Max.Rec.Wt.Each ;=�A e StAze B AC,. D E Load/tbs. (in lbs.) '/2 3/6 1718 17/,s ( 23/4 3'/,s 300 .10 i 314 3/6 1"/16 1e 2'/2 311,6 300 .10 fi 1 1 316 15/8 1 2'/2 33/,6 300 .10 C 3/6 1'5/,6 1'/,6 213/18 3'3/,6 300 .11 I B 1112 3/6 211a i'!,6 31/e 37/6 300 .11 2 3/e 2'/:;, 1'/s I 35/16 43/6 300 .14 1 E D r 2'12 3/6 23/4 1`/ 3 11/,6 I 5 525 .19 3 3/6 27/a 1'!e 3314 1 55/,6 525 .23 3'/2 -/6 3318 13/a 45/,a 65/,s 525 .25 k 4 3!9 3711 1`/2 41!2 I 7 650 .30 5 1/2 4'/a 15ia ( 55/a 6'-/6 1000 .50 6 1/2 5518 2'/4 6'!2 ( 913/,e 1000 .56 8 1/2 613/,s 2'/,6 715/16 12'/4 1000 .90 Note: If ordering Fib.14IF felt lined hangers for pipe sizes of 3'1.°or under order the next largest-size to alloar for-the thickness of the felt lining. MATERIAL: Low carbon steel FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The knurled insert nut,allows for vertical adjustment after installation. FM 11 Fig.151F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound. R. —HANGER E APPROVALS: Underwriters'Laboratories listed and Factory Mutual approved Fig.151 21/,'"to 8"sizes only.Complies with Federal Specification A-A-1192A (Type 10),and Manufacturers'Standardization Society SP-69(I'ype 10). Fig.151 PRE-GALVANIZED ORDERING: Specify pipe size and figure number. Fig.151F PRE-GALVANIZED WITH FELT LINING Rodl Pipe !Size j Adj. Max Rec VMt.Each ` - A Size A E C _ pT E Load/lbs i (in Ibs) 2'/2 '!2 2314 j 1'4 3 11/,6 5'/e` 600 .33 3 '/z 3'/a 1'/a 4 5% 600 .35 3'/2 /2 35/a I 11!2 45/,6 65•/e 600 .37 IG 4 i 5/s 37/6 1 11/4 4'S/i, 716 1000 .48 5 1 5/6 4'/a 1319 55/a I 81/2 1000 .57 6 3/4 ! 55/16 I 2 611/1; 10'/a 1250 1.06 D 8 3/4 ! 6'5/18 2518 85/,6 12'/;i 1250 1.32 E Note: If ordering Fig.151E ell lined hmrgers or pure sizes of 31/?"or under,order the neat &rrgest size to alloly or the thickness of the felt lining. ! T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts MATERIAL: Low carbon steel Inspection Agency eA,waa=��,pep,o,ma a PHD Manufacturing, Inc. 25 wnn sa,e a„>aoy cones Date Jul 31,2015 Appeal a aces 1--or appmve a"y omss w aewa,�nompra,epmen,eMS a roue su,e Ewa. FUNCTION: Designed for non-insulated stationary pipe lines in either a hori- Vi �0&51 zontal or vertical position. [ ' ' EXTENSIP_N SPLIT* APPROVALS: Complies with Federal Specification A-A-1192A(Type 12)and Manufacturers'Standardization Society SP-69(Type 12). �' P MATERIAL: Malleable iron Fig.510 PIPE THREAD Fig.5108 BOLT THREAD FINISH: Plain or Electro-galvanized ORDERING: Specify pipe size, finish and figure number. A A Pipe Pipe Thread Bolt Thread Max.Rec. Wt.Each ==t Size Fig.510 Fig.51 OR 8 Loadilbs. jin lbs. 3/8 1/4 3/8 13/16 180 .13 3/8 '/a I 180 .14 112 1J4 i •1, 3/, 3/6 3/a 1 180 .16 1 /4 3/a 1'/8 180 .18 Y. 14 3/a 15/16 180 22 B 11/2 1/4 3/a 17/16 180 1 .38 2 1/4 3/8 1„/,6 180 .44 21/2 1/2 112 21/e 300 1.05 3 112 7/2 2'/16 300 1.40 4 1/2 1/2 311/32 300 1.60 FUNCTION: Designed for non-insulated stationary tubing tines in either a Fi ' horizontal or vertical position.The hinged design of Fig.512H allows for a quicker installation. C0 $ #"�. SION APPROVALS: Complies with Federal Specification A-A-1192A('Type 12)andT Manufacturers'Standardization Society SP-69(Type 12). yr i MATERIAL: Malleable iron Fig.512 TWO PIECE DESIGN FINISH: Copper color epoxy finish Fig.512H HINGED DESIGN ORDERING: Specify tube size and figure number. (,;��,i A Tube Rod Size Max.Rec. Wt.Each(in lbs) Size A B Load/lbs. Fig.512 Fig.512H 3/13 3/8 9/16 180 .07 .08 1/2 3/8 1/,6 180 .09 .09 ` 1 3/4 3/8 7/8 180 .09 .12 � l 1 3/8 1 180 .10 .11 B 1'/4 3/B 11/6 180 .12 , .15 11/2 3/8 15/16 180 .13 .20 2 3/8 17/2 180 I 18 .25 21/2 112 17/6 300 If .65 .72 �12 F7- 3 1/2 2'/8 300 1.00 1.07 Fib. sUozrn 4 '/z 23/4 300 1.40 1.50 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 5[ AccrMitetl Evaluation antl Insp—im Agency PHD Manufacturing, Inc. nrs 6xumemi cm. as engm muma�- wnn Aam aunm,g CoJesm Da Jul 31,2015 ropwxu+ze�umemm� SAMMVW HORIZONTAL MOUNT for ood Not less than 2'nom width p Product Features (1-1/7)up b 3.1/2'pipe;not less then 3'(2-1?)rnmina With 4'8 5'pipe •No pre-drilling required.IN Floor)lest Quick to install using the Samni � I.tinimum 2�1r1'from botbm For branch foes.lAnimum 3'f om Nut Driver with an 1 BV cordless bottom for main hies.Exception:This drill/driver. requirement shell not apply b 2'cr thicker neilng strips ie"on top of steelbeams. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 ` ElkhaA,IN 46514 _ - Statefs) Massachusetts Accredited Evaluation and 11: Inspection Agency This tlocumem is certirietl as being in conformance _- wirh Sate 1 C.— Date Jul 31,2015 nrao"ai w This aoeamani aoe awho,iz ,a�rwe 12111 Hill i any omisi nor tlehation nom the require,nnb nl de Sure tzws. :r. 1f4�.: tyYlA957 '"SWl 114X1' 622(Flry- - 114" 8019957 SWG 200 1/4x2' 1725(Fir) 25 125 318 802Gb7. SWG 10 414 X 1' 672 jFirj i 300 25 125 . I ylQ. W 8021957 SWG 20 114x2' 1725(Fit) 1050 25 125 318• 8073925 SWG20SS 111 1725(FS) '; 850 25 125 #14 SW Red Q 318' 80'12925 SWG 25380 3/8x2-112' 2249(Fit) 1500 25 125 NN Dover 31V 8023925 SWG30 1/4x3' 1884(Fir) 25 "125 Part#8114910 S" 1.Insert the appropriate nut driver into a 378'or 112'portable drill. 1.Insert the appropriate nut driverinto a 3/8•or 1/2'portable dn71. 2.Insert the SAMMYS into the#14(black)nut driver(p7n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(18 114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver fight to the member.When the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins free on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now ready to receive 114',378;112'ormetric all thread rod,bolt stock.(The 112'requires the#14SW red nut driver) 4.The unit is now ready to receive 114",3B"or metric all thread rod or bo#stock. Note:When installing DSTR,follow the above into ctions, then add retainer nut and torque to 20 foot lbs.for maximum Note:When installing SWDR,follow the above instructions,then add retainer nut pullout in pudin steel. and torque to 20 foot lbs.for maximum pullout in pudin steel. SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which presides a fast and safe installation each time.When the face of the driver canes into contact with the material you are installing into,conlinue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate ntl driver for installations. To find a distributor near you,call 800-BUILDEX SAMMYV for f i P No pre drilling required, 1 NoilessMn ; •Quick to install icing the Sammy 3'nomma ' Nut Driverwthan Wcordless tti`itness q-1m I drill/driver or sib YbodJdst ot•rErric�mar�erJ Saves time from traditional oaave methods. C9 rl+Q Reduces installation cast_ - Made in the U.S.A r + T.R ARNOLD&ASSOCIA1 ES,INC. P.O.R.-1081 Elkton!,IN 46514 ' ���"^' •• Slates) Massachusel Accredited Evaluatio d Inspection Agency I ims DOCUn¢ni iscm as UCyinc b mare I vnm Since un"mg Cones. Dale eJul 31,201 31 + nwu.-nian I.. aPv�w y .s" meey i i4•` 80 3 157' GST100 114,x 1 6M(3 . 6 os� ?� 25 670(3W Ply) . 114' 8001957 GSST200 114x2' 1760 Fr) 25 125 `iM'" E901SSI GST300 114x3" :060(Fr) 25 125 30 8006957 GST 75 114 x314" 564(3f4'Ply) 25 125 .. 3B"' 000798/` G5714 1!4x.1° 2iD(7M S'OSB) 125 fi70(3M 1?fi) 318" 8003957 GST20 114x2' 1760(Fir) 850 1475 25 125 318 8068925" " ' GST20-SS 114x2' 1760{Fr) ' 950" 25 125 30 80%S25 GST25-M 3!8x2-12' 2113(Fr) 1500 25 125 #14 Black ;Q 38 8010357 GST30 114x3° 2060(Fr) '1x0 1475 25 1,12?: Nut Driver 318` W69925 GST30-SS 114x3` 2060(Fr) 25 125 Part 48113910 3B 8011925' GST4Q ' 114 x4' 2180(IFirI 25 125 3,8" W12925 GST60 1/4x6' 2230(Fir) 25 125 tlr - 8013925 GST2 114x-2 17600716 ?5 125 �12" 8014925 GST25-380 Wx2-10 21113(Fir) 25 1251 sDi5325 GST3 114 z3" 2275(flr) 25 125 12' 8016925 GS T4 V4 x 4" 2180(Fir) 25 1 W 801792$- GST6 1!4x6" 2230{Fr) 25 ' " '125 #14 SW Red Nut Driver Part#8114910 - , t � � e Elimnales distortion of threaded md. Saves time from traditional methods. 4 ill Accommodates upto 31h x 12 pitch roof. Reduces installation cost. Allows-17'deflection from vertical. Male in the USA 8139317; SH-GST?0" 114x2 1257(Fi)" 1LG0 1475: 25 - 125 125 Q '3,T 8141961 SH-GST30 iM x3' 1720(Fir) 15)0 1475 25 125 J#14 Black Nut Driver 45! 1T DA l`i'LM Mt The nul drivers were designedwith a unique spirFdf feature which provides a fat and safe installation each line.When the faced the driver cores into Pad#8113910 cortad vrih the materialyou are installing into,continue drilling until nut driverspiis free.Installation 6 then corTlete.Warranty requires the used the appropriate nut divertorinstallatiors. Certificate of i i + ' Certificate Number 20060214-RI3240E Page 1 of 1 Report Reference 2006 February 14 Issue Date 2006 February 14 Underwriters (. Laboratories Inc. T.R ARNOLD&ASSOCIATES,INC. Issued to: H i Iti Inc. P.O. 465 1 Elkha rt,IN 46514 5400 S 122ND East Ave State(s) Massachusetts Tulsa, OK 74146 USA Accredited Evaluation and Inspection Agency This is to certify that Fill, Void or Cavity Materials This document is certified as being in conformance with State Building Codes. representative samples of FS-ONE Date Jul 31,tots Approval of this document does not authorize or approve any omission or deviation from the requirements of a li.ble Slate Laws. Have been investigated by Underwriters Laboratories Ines@)in accordance tvith the Standard(s) indicated on this Certificate. Standards)for Safety: ANSI/UL 1479, ANSI/UL 2079,CAN/ULC-S115-05 Additional Infortnation: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through- Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle symbol: with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL: a statement to indicate the extent of UL's evaluation of the product;and,the product category name(product identity)as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issued byC� Reviewed by: �ouloute Christopher o on Underwriters Laboratories Inc. Underwriters stories Inc. T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 state(') Massachusetts Accredited Evaluation and Inspection Agency Material Safety Data Sheet ThnJOCVmcnl'i5 cen,lietl as being in conlo maze wim sae soxen1 cones. MSDS No 259 Date Ju131,2015 : A­1. n — aW— Revision No.: 010 any i1o�an-�ae.a,00-om me,en e�uo, Revision Date: 08/17/04 Page: 2 of 2 Carcinogenicity: IARC classifies crystalline silica(quartz sand)as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure(via inhalation)to silica dust;e.g. mining,quarry,stone crushing,refractory brick and pottery workers. This product does not pose a dust hazard;therefore,this classification is not relevant. Based upon the nature and intended use of this product,it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin,use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician.If a large quantity was ingested,give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General(natural or mechanically induced fresh air movements). Eye Protection: Not required,however,safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact.Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors,use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool,dry area preferably between 40o and 77o F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene;i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow Iabelfuse instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local,state,or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated- IATA/ICAO Shipping (tame: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory.SARA Title 111,Section 313:This product contains<3%ethylene glycol(CAS 107-21-1)and<15%zinc borate(re:zinc compounds)which are subject to reporting under Section 313 of SARA Title III(40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local,state,and federal safety,health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health/Safety: 1 800 879 6000 Jerry Metcalf(x6704) Emergency q (Chem-Trec): 1 800 424 9300(USA,PR,Virgin Islands,Canada); 001 703 527 3887(other countries) The information and recommendations contained herein are based upon data believed to be correct;however,no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. HIM Firestop Saving Lives through innovation a and education Hilti. Outperform._Outlast. i.'Ti,inc.(U.S.}1-800-879-8000•www.us.Niti.com•en e pahoi 1-800-879-5000•hi�,i tCanadaj Coto.1-800-363-4458 wwwAlltLea M aterial Safety Data Shoot MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 1 of 2 Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti,Inc. P.O.Box 21148,Tulsa,OK 74121 Emergency#(Chem-Trec.): 1 800 424 9300(USA,PR,Virgin Islands,Canada);001 703 527 3887(other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylale dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m'M 10 mg/m'(T) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 mg/m` NE Expandable graphite 012777-87-6 5 mg/m'(f) 2 mg/m'() NE Ethylene glycol 000107-21-1 NE C:100 mg/m'(A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m' 5 mg/m' NE Glass filament 065997-17-3 NE 5 mg/m3 M NE Silicon dioxide 014808-60-7 0.05 mg/m3(T) 0.1 mg/m'(f) NE Water 007732-18-5 NE NE NE Abbreviations: PEL=OSHA Permissible Exposure Limit. TLV=ACGIH Threshold Limit Value. C=Ceiling. STEL=Short Term Exposure Limit. NE=None Established. NA=Not Applicable. (T) indicates"as total dust'. (R)indicates"as respirable fraction". (A)indicates"as an aerosol". mppcf=million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless, Vapor Density: (air=1) Not determined. Vapor Pressure: 23mbar @ 20C/68F Boiling Point: Not applicable. VOC Content: 75.0 g/L Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire- Special Fire Fighting Procedures: None known.Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phosphorous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids,peroxides,and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Medical Conditions Eye and skin conditions. Aggravated by Exposure: T.R ARNOLD s ASSOCIATES,INC. E.o.s Routes of Exposure: Dermal. I 1081 arl,I ElkkN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency inn a«u,remrsrent i.as be,g in,.mi«mane —1h S Ii,eunomg t;oee pate J"131,2015 Hilti Firestop Saving Lives through innovation and education Hilti. _Outperform. Outlast. H116,Ire.(U.S-)1-800-879-8000-www.us hiftcom-6n espancl 1-800-879-5000-Hi:7i(,; -"aj Cc,!p.1-800-363-4458 www.hlltI.ca TX ARNOLD&ASSOCIATES,INC. P.O.B•.1081 Elkhart,IN 46514 Stater') Massachusetts Accredited Evaluation and minim MEN= Produot Information A - Date Ju131,2075 High Performance n -- Il'tumescent Firestop Sealant ' - s Product description Intumescent(expands when exposed to fire)firestop sealant that - helps protect combustible and non-combustible penetrations for up to tours fire rating Product features • Smoke,gas and water resistant after material has cured • Contains no halogen,solvents or asbestos = a • High fire rating properties • Water based,easy to clean _ • Protects most typical firestop penetration applications • Can be painted • Single component systems available FS-ONE Technical Data Chernical basis Water-based inturnescent acrylic • Meets LEEDTm requirements for indoor environmental quality credit dispersion 4.1 Low Emitting Materials,Sealants and Adhesives and 4.2 Paints Cdor Red and Coatings Application terrneratLce 40T to 1041E(6*C to 40•c) Sidn'forrrfng fvne.:'. Approxr 20-30rrin Areas of application Curing filing Approx.2mm/3 days • Steel,copper and EMT pipes Movement capability Approx.s% E>pansion rate lip to 3-6 tuY1eS • Insulated steel and copper pipes (unrestricted): original volume • Cable bundles Temperature resistance(cured) -4WF:to 2121F(-4010 to 1100°0) Surface burning characteristics Flame Spread:0 • Closed or vented plastic pipes (ASTM E 84-96) Sn;oke Devefopmenr s HVAC penetrations Sound cransmsCon classification 56(Relates to specific construction) • P (AS,Z E 90-991 Approvals For use with CaGtomia State flre:Marshai Llskig.No.4488-1200108 • Concrete,masonry,drywall and wood floor assemblies City of New York MEn 326-96-M Vol.IV Teared In accordance vdh •UL 1479 • Wall and floor assemblies rated up to 4 hours •ASTM E 814 •:ASTIO E 84 Examples At 73F(23 C)and 6045 re!aWa Mmidity • Sealing around plastic pipe penetrations in fire rated construction • Sealing around combustible and non-combustible penetrations in FILL,VOID ORCAWY11ATEIdAL FOR USE IN THROUGHL'ENEI RATION fire rated construction FI ESTOP SYSTEMS FM MIX=a •ATULK SEE UL FIRE DESISTANCE OIRECTCRt' E6Yr APPROVED Installation instructions for FS-ONE Notice 4. Smoothing or firestop Sealant:To complete the seal, On n"Ierials where oil,plas"ors or solvents may • Before handling,read Material Safety DataShwl and rod Immediately ediately to give a smooth appearance. bleed Le.Impregnated wood,di based seals,green product label kor sale usage and health Information. Excess sealant,prior to wring,can be Cleaned or partially vulcanized rubber • Instructions below are general guldeiknes—always away from adjacent surfaces and toots with water. . In any penetration other than those specifically refer to the applicable drawing in the UL Fire 5. Leave completed seal undisturbed for 48 hours. described in this manual or the test reports Resistance Directory or HIM Hrestop Systems Guide 6. For maintenance reasons,a penetration seal could for complete Installation Information be permanently msrkod with an Identification plate. Storage In such a case,mark the Identification plate and Store fed in the original at temperatures In e location between Opening protected from moisture at temperatures between 1. Clean the opening.Surfaces b which FS-ONE will be fasten it In a visible position next to the sea). 401E(5-C)and 86-F(301C) applied should be cleaned of loose debris,dirt,oil, Not for use Obwve expiration date on the packaging moisture,frost and wax.Structures supporting High movamont expansion idnts penetrating Items must be installed In axnpkiaroe Underwater with local building and electrical standards. Application of firestop sealant 2. Install the proscribed backfilling material typo and ILI - depth to obtain the desired rating fif required).Leave a trti T 1 sufficient depth rorappying FS-ONE. - 3. Application of firesbp seataot Apply FS-ONE to One required depth In older to obtain the desired flip rating. Make sups FS-ONE contacts all surfaces to ptovicla maximum adhesion.For application of FS-ONE use a Of requinid) FS-ONE. %W undalsbed for 2 putt p requre4 stanclad Caulking gun,foil pack gun,hulk loader and ear_ bulk gun.With FS-ONE buckets,G"taco,type sealant 499449MEMI I pumps may be used.(Contact pump manutwtuer for _ ......_ Properselsctlon). x jhlffi � � Nil - 1.Clean opening. 2.Pack mineral wool. s - - �, tlfrc4ura0 FS-ONE s Ia dSlubedto48 Ider4RCahon pate(Ir noun required} _Outperform. Outlast. Hilt, Inc_(U.S.)1-800-879-8000•www.us.hilti.corn •a,�e-spanol 1-800-879-5000•Hiiu Fir&stop Systarns Es-c:+._)0 BANGLE INLET An inlet connection with 250 G.P.M. minimum inlet capacity to supplement the fire protection water supply. Provides unobstructed water supply. Flush round design enhances , appearance and provides unobstructed passage. <y STAND QUIPMENT:Cast Brass round plate w' uble female adapte and chain; branding as sele SPECIFYTHREA BRANDING. BRANDING: "Standpipe", "A FINISH: Cast Brass Figure No. 6341 Figure No. 6342 OPTIONAL FIN B-Polished Brass PC-Polished Chrome Round Plate Figure No. Size 6341 2 1/2 X 2 112 6342 3 X 2 1/2 6343 3 X 3 RESIDENTIAL FIRE DEPT. CONNECTION An inlet connection to supplement the water supply to a fiy °w residential sprinkler system. � STANDARD EQUIPMENT: 1 1!2"cast brass round plate assembly with integral pin lug swivel inlet. Hose thread inlet l swivel, 1 112" NPT female outlet on back of plate. Cast brass p plug and brass chain. Overall outside Diameter 4 318". SPECIFY THREAD AND BRANDING. U/L LISTED. T.R ARNOLD&ASSOCIATES,INC. BRANDING: "Auto Spkr." P.O.sox 1081 FINISH: Cast Brass Elkhart,IN 46514 State(s) Massachusetts Figure No. 6345 Accredited Evaluation and OPTIONAL FINISH: PB-Polished Brass Inspection Agency PC-Polished Chrome This document is certified as being in conformance with State Building Codes, Date Jul 31,2015 Approval of this document does not authorize or approve any omission or tlevnlion from the requirements of a likable State Laws. Page 6-12 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency FLOW CHARACTERISTICS wa sur°a"a°mq c°nes. Date Jul 31,2015 MODEL 950XL 314", 1",1 114",l 112"8t 2"(STANDARD&METRIC) FLOW RATES(I/s) 15 1.26 2.52 3.8 5.0 15 3.2 6.3 _ 9.5 12.6 9MM) 15.8 a 314"(20m m) 1"(2 mm) 1 114"(32mm)� 12"(40mm)t2" 103 x U) 0 10 10 69 O LU 5 5 35 N N to W W 0 0 a 0 20 40 60 80 0 50 100 150 200 250 a FLOW RATES(GPM) O Rated Flow(Eslablished by approval agencies) TYPICAL INSTALLATION Capacity thru Schedule 40 Pipe Local codes shall govern installation requirements. To be Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec installed in accordancewiththe manufacturer's instructions 1/8" 1 1 2 3 and the latest edition of the Uniform Plumbing Code.Unless 114" 2 2 3 5 otherwise specified, the assembly shall be mounted at a 3/8" 3 4 6 9 minimum of 12"(305mm)and a maximum of 30"(762mm) 1/2 5 7 9 14 above adequate drains with sufficient side clearance for 3/4" 8 12 17 25 testing and maintenance. The installation shall be made 1" 13 20 27 40 so that no part of the unit can be submerged. 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 2" 52 1 78 105 167 PROTECTIVE ENCLOSURE •i I II b b r 12"MIN. 12'MIN 30"MAX. 30"MAX DIRECTION OF FLOW DIRECTION OF FLOW OUTDOOR INSTALLATION INDOOR INSTALLATION SPECIFICATIONS The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves.The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF®Listed NoryIT"" and the seat disc elastomers shall be silicone. The first and second checks shall be acces- sible for maintenance without removing the device from the line.The Double Check Valve Backflow Preventer shall be a WILKINS Model 950XL. WILKINS a Zurn company, 1747 Commerce Way,Paso Robles,CA93446 Phcne:805/238-7100 Fax:805 1238-5766 IN CANADA:ZURN INDUSTRIES LIMITED,3544 Nashua Dr.,Mississauga,Ontario L4V 1L2 Phone:905 1405-8272 Fax:9051405-1292 Product Support Help Line: 1-877-BACKFLOW(1-877-222-5356) w Website:http://wwwzurn.com Page 2 of 2 T_R ARNOLD&ASSOCIATES,INC. Elkh,rL IN 46514 ��F��� /�-��/—��Y ��1 ���� � ��_-��� u ���� ���- - � � m�_�k`� ������U\/� � ������_�� � APPLICATION Designed for installation on potable water lines toprotect against both baokoiphonage and bachpnassurenfpolluted water into the potable water supply.Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (A|| sizes approved horizontal. Vertical approvals ms listed below.) ° ASSEG Listed 1O15(vertical 3/4'. 11/4". 11/Z'&Z) FEATURES ° |APMCx6Usted (vertical 1 1/4"'2^) Sizes: 03/4' O1" [J1-1/4^ O1'1D^ O2" " CS/O Listed (vertical 3/4'. 1 1/4''. 1 1/2' &2^) ° /WVVA Compliant C51D(vertical 3/4') Maximum working water pressure 175 PSI ° ULO0 Classified (less shut-off valves only) Maximum working water temperature 180~F ° C'UUm Classified(less shut-off valves only) Hydrostatic test pressure 350 P8| ° Approved by the Foundation for Cross Connection End connections Threaded ANSI B1 2O 1 Control and Hydraulic Research at the University of OPTIONS Southern California (vertical 3/4') (Suffixes can becombined) ° City nf Los Angeles Approved (vertical 1'1N^'2') ° NYC MEA42O'89'M VOL3 0 ' with full port OT ball valves (standanj) K&uTEB8uLS 0 L less ball valves O U wi�hunionba||va|vea Main valve body Ca�� Bronze AGTMB5O4 Access covers Cast BrnnzeASTM B584 B S ' with bronze''Y^type strainer Internals Stainless Steel 300 Series 0 TCU - w�htedcocks've�ioe|^up ' B O V with union swivel elbows(3/4.&1.) astome'a S||icone(FDAapprnved) B DSY w�hOG&Y gate va�es DunaN�h|e (FDAappmved) O FDC w�h�ne hydrant oonnoodon (2..only) Polymers Nory|`w. N8FLi��ed O FT with intogra| ma|e 45"OareSAE0eaLf�ing �Pringn �tain!easoteei �OO series ACCESSORIES 0 Repair k�(rubber only) 0 Thermal expansion tank(Model VXTP) O QT-SET Quick Test FitdngSet O Te�Cock Lock(Model T( L24) O DIMENSIONS&WEIGHTS(do not include pkg.) G DIME SIONS(approximate WEIGHT MODEL A UNION B LESS BALL LESS WITH SIZE A BALL VALVES G D E F G BALL BALL VALVES VALVES VALVES 1 112 435 19118 486 109116 268 2 51 31/2 89 4 1/2 114 4 1/2 1141223/4 578 16 7.3 10 Page I of 2 wILKINS a Zurn company,1747 Commerce Way, Paso Robles,CA 93446 Phone:8051238-71 00 Fax:805/238-5766 In Canada:Zunw INDUSTRIES LIMITED,3s**Nashua oc.Mississauga,Ontario L^v1 L2pxonr:9051405-8272 pox:905w05-1292 Product Support Help Line:1'877'aAcxpLmw(1-877-222-5356) ^ wmumm:mnn:x,w,Kaum.cum Ordering Information: Residential Riser Part Number Code Key 1N B 0 1 M T39 1 1.5N T716 1.5M T12 0=Assemtly without Pressure Relief Kit 2N 1=AssemblywilhPressureReIieiKfl 2M B=Basic TrimAssernbly T33=Basic TrimAssernnlywdi W(1Qnm) Ont Test&Drain Valve T.R ARNOLD&ASSOCIATES,INC. 1N=1'(25rrm)NFT Threaded Ends Assffnbly P.O.Box 1081 1 M=1'(25rrrn)Metric Threaded Ends Asse ably 1716=Basic Trim Assrrnbfyv 417116"(11 nun) EWhart,IN 46514 Olif.Test&DranVahre State(s) Massachusetts 1.51\1=1-112'(4am)NPTThreaded Ends Asserrtbly Accredited Evaluation and Ti�—Basic Trim Asserri�ly wtlh/-"(15rrm) 1.5M=1-10(40m)Metic Threaded EndsAssen-bly Oni Test&Drain Valve Inspection Agency This document is certified as being in conformance 211=2"(5(7nrn)NFT Threaded Ends Assanbly with State Building Codes. 2M=2'(5(7rm)Melnc Threaded EndsAssernbly Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. Example#1: 1.5N —B — 1 (1-1/2"(40mm) Residential Riser Assembly with NPT Female Inlet and Outlet Threads, Basic Trim with installed Pressure Relief Kit). Example#2: 2M —T12 —0 (2" (50mm) Residential Riser Assembly with Metric Female Inlet and Outlet Threads, Basic Trim with TestANDralri Valve having a'/2"Diameter Test Orifice.) Also, If Required: Description Part Number Pressure Relief Kit For Basic Trim 98020076 Pressure Relief Kit For Basic Trim with TestANDrain' Valve 6501203550 -Support Bracket Kit 6399190001 The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting fife and propertylot over 86 years,and are installed and serviced bythe most highlyqualitied and reputable sprinkler contractors located throughout tfie United States,Canada and foreign countries. Manuiactured by The Reliable Automatic Sprinkler Co.,Inc. Recycled (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax Reliable (914) 668-3470 Corporate Offices Revision lines indicate updated or new data www.reiablesprinider.com Internet Address EG.Printed in USA 3M Pl1,19999970207 (12.1 bar). Cast-in mounting holes are provided for two sets of SPDT(Form C)contacts, having recessed or flush mounting to a wall. For stud an electrical rating of 10A @ 125/250 mounting, a support bracket is available that is VAC/2.5 A @ 24 VDC. Triggering flow rate is specifically designed forthe cast mounting holes, 4(15) GPM(LPM) to 10(38) GPM(LPM). All of the trim variations include brass Pressure Relief Kit shall be provided to components,acULus Listed 300 psi water pressure maintain system pressures below 175 psi gauge, and a dedicated cULus Listed Waterflow (12,1 bar). Detector. This Waterflow Detector comes factory installed with a weatherproof (outside)cover. Installation: 1. Install the manifold with the flow arrow pointing Trim Descriptions towards SYSTEM side using threaded P connections. • Basic Trim 2. Connect a 1- NPT drain line. Ensure the drain Residential riser manifold assembly trim Ball Valve is in the CLOSED position. shall include a cULus Listed pressure 3. Place the sprinkler system in service. gauge, a drain valve, and dedicated Caution: waterflow detector containing two sets of Automatic sprinkler systems having non-fire SPDT(Form C)contacts, having an protection connection (permitting continual water electrical rating of 10A @ 125/250 VAC/ flow)require dielectric fittings, according to NFPA 13 2.5 A @ 24 VDC. Triggering flow rate is sect.4-6,when dissimilar metal piping materials are 4(15)GPM(LPM) to 10(38) GPM(LPM). joined. • Basic Trim with Pressure Relief Kit Note: T. ARNOLD P.O.ASSOCIATES,INC. .Box 1081 Residential riser manifold assembly trim Use a non-hardening pipe joint ElkkM IN huset Statels) M.....huse[ts shall include a cULus Listed pressure compound, or tape. A—dltWE -t-and 1-peabn Agency gauge, a drain valve, and dedicated • ee °°ma waterflow detector containing two sets of 2 1.12" MINIMUM G4P FOR WATER FLOW,ND,G4TDP, owe J.31,zU15 SPDT(Form C)contacts, having an COVER REMOVAE(nP,c4L Al 94N,ucas, °a,omm a electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM).Pressure _ relief valve kit shall be provided to maintain I r system pressures below 175 psi(12.1 bar). • Basic Trim with TestANDrain' Valve STUD SUPPORT BR4CF'c7 NOUM17 Residential riser manifold assembly trim gWCKET FLUSH shall include a cULus Listed pressure s MI °` gauge, aTestANDrain" valve, and a dedicated waterflow detector containing Fig.6 two sets of SPDT(Form C)contacts, having an electrical rating of 10A @ 1251250 znoD PANEL PLASTIC SPACERS VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). The test orifice size for the TestANDrain' assembly shall be(choose one): r • • (10 mm) J (11 mm) ------------------- • '/z• (15 mm) • Basic Trim with TestANDrain Valve & � Pressure Relief Kit �J Residential riser manifold assembly trim i_JJ a=-= shall include a cULus Listed pressure gauge, a TestANDrain' valve, and a RECESSED OR.FLUSH MOUPIEED dedicated waterflow detector containing Fig.7 3. Optional Trims - Technical Data: Desctp[ixl basic Trim Basic TrRe self Kit Pressure Te�NDraW Va kre &Preemie Petal TaIROLI I'dani(ot1 x Dimension Size_ Dilw>ISiatr Dintensiors t p Dmensiors Ulkight omemiaris Weght inch inch Lbs inch irrh Lbs inch inch Lbs inch iW-i Lbs inch mm mm (kgs) rrim mm (kgs) mm mm (k9s) mm mm (kgs) mm 1• 11 912 7.5 13 11 9.5 11 10y 8.8 133/4 11 Y2 9.8 8y 25mm 279 241 3.4 (3 279 4.3 (279 2267 4.0 349 (292 44 210 1J?• 11 10 8.5 13 11x 105 11 11j; 9.5 1334 12 10.4 8y 40mm (279) (254) (3.85) (330j (292) (4.75) (279) (286) (4.3) (349) (305) (4.7) (210) 2 11 10/' 9.0 13 12 11.9 11 12 10.3 13 3i< 12 11.4 8 j+� JJmm 279 264 4.1 3 335 5.0 279 305 4.7 349 3i8 52 210 "Support Bracket Kit(optional)-1 lb(0.45 kg) All Reliable Risers have a 1• NPT drain pat. Basic Trim Basic Trim with TestANDrainO Valve B B Press. Relief Kit Wat Pressure Gauge Press.Relief 7ressum Gauge (opt.) System Kit(opt.) System Manifold Manifold T.R AN OLD 6 ASSOCIATES,INC. P.O IN 06 Body Drain Valve Body\ .R ' N'.5 Ll \1a E fl, ' "' S4N�s) Maasxf,useRs � ��- retlitetl Evaluation and 1 spec n A9—, n5 aas y.—ono�z N J .mil _ eaw eoce:. � �tr� rev Jul]1 2015arc.sw A A C C (Take-Out) � _ (Take-Out} A Drain Support j Bracket(opt.) ILJr Support Supply Braclaet(opt.) Supply Drain TestANDraino Valve Water Flow Detector Water Flaw Detector (C o ntact R at ngs: 10 A @ 125250 VAC (Contact Ratings: 10 A @ 126250 VAC 2.5A @24VDC 2.5A @24VDC Fig. 5 Product Description: 1-}4• (40 mm)cast, non-welded stainless The Reliable-Risers come factor)assembled with all of the necessary accessoriesfor a cost effective, steel body with 1-�•femaleNPTor ISC�7-Rc1.5-11 threaded end connections. yet complete riser solution. Reliable-Rises are [cULus Listed] [NYC 2• (50 mm) cast, non-welded,stainless Approved MEA 258-93-E] for horizontal or vertical steel body with 2•female NPT or installations as a one-piece, factory assembled IS07-Rc2-11 threaded end connections. unit for use in NFPA 13D and 13R residential All of these manifold sizes have cast-on lettering systems. The riser manifold assembly shall consist that clearly identifies the manifold's pipe size,flow of a(choose one): direction, cULus Listing, and the test and drain 1• (25 mm) cast,non-welded stainless steel outlet. A built-in drain port is included to permit body with 1• female NPT or IS07-Rc1-11 hydrostatic testing without draining the system. The threaded end connections. assembly has a working pressure rating of 175 psi 2. Bulletin 416 Rev.0 co Imlab I ® Reliable Riser - Residential D Reliable Riser - Residential { 1" (25mm), 1 Y2" (40mm), and 2" (50mm) sizes. For use in NFPA 13D and 13R Residential Systems .R ARNOLD&ASSOCIATES,INC. P.O.Box 1061 Elkha4,IN 46514 Features: Statets) Massach°setts Accredited Evaluation and Inspection Agency 1. Stainless Steel body construction. $d1ea9 �Le 2. All brass trim. Fig.i Base Trim parse J.31,2015 3. Factory assembled. 4. Factory pressure tested at 200 psi, (13.8 bar). 5. Choice of trim: • Basic Trim (Fig.1). • Basic Trim with Pressure Relief Kit (Fig, 2). • Basic Trim with TestANDrain' Valve (Fig. 3). • Basic Trim with TestANDrain* Valve and Pressure Relief Kit (Fig. 4). Fig.2 Base Trim with Pressure Relief 6. Choice of mounting options: Kit • Supply/ System lines support. • Support Bracket (to stud) (Figs. 5 &6). • Recessed or Flush mount Ct (to wood panel) (Fig. 7). 7. NPT (female x female) or tapered metric (female x female) connections. 8. Slim design allows for easy installation within 2• x 4•on 16• centers wood frame construction. 9. Dedicated UL Listed Water Flow Detector Fig.3 Base Trim with TestANDrairt Valve assures optimum sensitivity. Water Flow Detector is factory installed with a metallic, weatherproof cover. Triggering flow rate is w 4(15) GPM(LPM) to 10(38) GPM(LPM). Approvals $ Listings 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada(cULus) 2. NYC MEA 258-93-E Fig.4 Base Tarn with TestANDrainf Valve&Pressure Relief Kit The Reliable Automatic Sprinkler Co.,Inc., 525 North MacQuesten Parkway,Mount Vernon,New York 10552 Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges Identification signs • Electrical sprinkler alarm switches • Fire department connection • Water flow detectors T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of a licable State Laws. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed byReliable have been protecting life and propertyfor over 90 years,and are installed and serviced bythe most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,Inc. Recycled ® (800)431-1588 Sales Offices Paper ''able (800)848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.rellablesprmkler.com Internet Address EG.Printed in USA 02/11 PM 9999970175 a i Fig. 12-G3 RJC Wrench Fig. 13-G3 RIC Wrench Fig. 14-G3 RIC Wrench 4 Fig. 15-G3 Wrench T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. 9. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION i / T.R ARNOLD&ASSOCIATES,INC. / P.O.Box 1081 Elkhart,IN 46514 State(s) Ma sachusetts FEMALE FEMALE Accredited valuation and I Inspection Agency PIPEPIPE This document is certifie J as being in conformance THREAD THREAD with State B jilding Codes. Date Jul 31,2015 INCORRECT CORRECT Approval of this document i Ines not authorize or approve CPVC ADAPTER CPVC ADAPTER any omission or deviatio 6omthe requirements of a licable Stale Laws. FITTING OR TEE FITTING OR TEE RELIABLE MANUFACTURES A FULL—LINE OF MODEL F3—PL MODEL F3QR—PL AND MODEL DH56 HSW—PL DRY SPRINKLERS THAT HAVE A SHORTER INLET FOR THESE APPLICATIONS. SHORTER LONGER i INLET INLET MALE ANAL E PIPE PIPE THREAD THREAD � I MODEL F3—PL, STANDARD MODEL F3QR—PL OR MODEL F3, MODEL DH56 HSW—PL MODEL F3QR OR DRY SPRINKLER MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016ig08 Fig. 11 8. RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NPT SIDE OUTLET EXPOSED BARREL OF A MALLEABLE IRON TEE FITTING AMBIEM AMBIENT TEMPERATURE r-t-______-------- PER ANSI B 16.3(CLASS 150) TEMPERATURE - -'"- r--- ---� OR CAST IRON THREADED TEE FITTING OF PROTECTED 40F/4'C SDTf 10'C 60'F/76C \ "II ; - ', �, PER AIV51 16.4(GLASS 125) ONLY. AREA"AT THE DISCHARGE END EXPOSED MINIMUM BARREL LENGTH" ly OF THE SPftINKtER (FACE OF TEE TO TOP OF CEILING) IN. (MM) IN.(MM) IN. (MN) Ij y IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 4D"F(4'C) 0 0 0 CAUSES CONDENSATION ON THE EXPOSED DRY SPP,INKLER,CONSIDER WRAPPING THE EXPOSED AM 30'F(-EC) 0 0 D I BARREL WITH INSULATION.FO INSULATING 2DF(-7-C) 4(101) 0 D TAPE OR EOUNALENT. I 7VF(-12'C) a(203) 1(25.1) 0 0'F(-18'C) 12 (305) 3(75) D MINIM (HEATED AREA) I SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINI(LER TO AVOID -101F(-23'C) 14(356) 4(101) 1 (25.1) BARREL LEAKAGE OF A[P, INTO THE PROTECTED -2C"F(-297C) 14(356) 6 (152) 3 (75) LENGTH I AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME. WHICH -30 FF(-3+'C) 16(408) 8 (203) 4 (101) I COULD INHERIT OPERATION OP. CAUSE PREMATURE OPERATION.SEE BELOW FOR -40'F(-40'C) 16(457) 1 (203) 4 (101) 'A' CLEARANCE RECOMMENCED METHODS. -50'F(-4EC) 20 (508) 10 (25+) 6(152) DIMENSION HDLE -60'F(-51-C) 20(608) 10 (25+) 6(152) i T.R ARNOLD&ASSO IATES,INC. ' THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. P.O.Box 1081 THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE Elkhart,IN 4 514 END OF THE SPRINKLER. ���/ State(s) Massac setts FOP, PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES LISTED,USE THE NEXT COOLER TEMPERATURE. Accredited EValua ion and Inspection Ag ncy "THE MIN.REQUIRED BARREL LENGTH IS NOT THE SAME AS THE'A' DIMENSION. �ESCUTCHEDN This document is certified as he gin conformance LVOTE� EXPOSED MINIMUM BARREL LENCTI{S ARE INCLUSIVE UP TO 30MPH CEILING wrth State Building odes. WIND VELOCITIES IN THE PROTECTED AREA Date Jul 31 2015 (PROTECTEB AREA) Approval amts documem does n autr—or approv eny wn_n,dev—n tram t e requir nts or e —3'Dik icahle State L ws. *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE { r''- -------r, rt-- -rl - -�- -I� I -14'+-- u t - I-;- -; - ini�. r-zJ f (HEATED AREA) CHEATED AREA)MINIMUM I MINIMUM EXPOSED EXPOSED BARREL BARREL LENGTH DECKTITE FLASHING INSIDE FACE I ��'EAL LENGTH (SEE ABOVE R J4-093910 ABOVE) (RECOMMENDED) CLEARANCE HOLE INSULATED FREEZER, OR COOLER STRUCTURE OR E7." FRAMIN TERIOR G Ej / (PROTECTED AREA) DRY SPRINKLER CPP.DTECTEO AP.EA) - DRY SPRINKLER NV COLD AREA IN COLD AREA Fig. 10 7. General Installation Instructions Maintenance Model F30R dry sprinklers must be installed only in stan- The Model F30R Quick Response Dry Sprinklers should dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) be inspected quarterly and the sprinkler system maintained pipe tees in the horizontal position,even at branch line ends. in accordance with NFPA 25. Do not remove the factory They should not be installed into elbows or pipe couplings applied thermally sensitive wax fillet between the bulb sup- located on drop nipples to the sprinklers. For these and porting cup and the wrenching boss. Do not replace this other fittings including CPVC*, the dry sprinkler should be wax with a substitute substance. An Alternate substance installed into a fitting to allow protrusion into the fitting in ac- may interfere with proper operation of the sprinkler. Do not cordance with the diagrams.The"A" dimension of the dry clean sprinklers with soap and water,ammonia or any other sprinkler,which extends into the freezers or a freezing zone cleaning fluids. Remove dust by using a soft brush or gently from wet pipe systems,should be selected to provide,as a vacuuming. Remove any sprinkler which has been painted minimum,the specified lengths in inches shown in Fig. 10. (other than factory applied)or damaged in any way. A stock Caution: of spare sprinklers should be maintained to allow quick Do not install Model F30R Dry sprinklers into CPVC replacement of damaged or operated sprinklers. Prior to adapter fittings or tees that have an internal obstruction. installation, sprinklers should be maintained in the original This will damage the sprinkler and /or the fitting. Refer to cartons and packaging until used to minimize the potential Fig. 11. for damage to sprinklers that would cause improper opera- tion or non-operation. During installation, the following steps must be followed: 1. Cut the specified size hole(see illustrations)for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model G3 or G3 R/C Sprinkler Wrench as specified. 3. Install the Model FP push-on/thread-off escutcheon or CCP cover plate if required. Note:Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems,as this may reduce the life expectancy of the sprinklers. Model F3QR Concealed and Recessed In- T.R ARNOLD&ASSOCIATES,INC. stallation Instructions P.O.Box 1081 • The Model G3 R/C wrench (Fig. 12) is designed to Elkhart,IN 46514 locate on the wrenching pads of the recessed sprin- State(s) Massachusetts kler while centering in the cup. A standard ''/2" drive Accredited Evaluation and ratchet may be used to drive this wrench. Fig. 13 and Inspection Agency Fig. 14 Show sequentially the insertion of the wrench. This document is certified as being in conformance First the wrench,with its jaws above the sprinkler de- with State Building codes. flector, is moved laterally until centered with the cup. Date Jul 31,2015 Then raise the wrench inside of the cup until its jaws Approval of this or deviation nfrom the,requirements ents of any omission or deviation from the requirements of engage the sprinkler's square wrenching pads (Fig. applicable Stale Law s. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector,with the wrench. • Model G3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation.REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 6. Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler "A"Dim. 3y2"to 48"(89mm to 1219mm)in l/4"(6mm)increments Finishes 5 inkier Escutcheon Collar ,;,ke, Bit [3zmmJ C Sy.lem Toe Sprinkler Cup 4 [t OS.6mm]NIn.� Chrome Plated Chrome Plated Chrome Plated Acs.mely 3 12' White Po ester(�) White White I"NPT �- '11 Other finishes and colors are available on special order. �� _ Consult factory for details. 4. --- [22 \ �z2mm] 121 cULus Listed as a Corrosion Resistant sprinkler in standard Black or ' = White. z I/2•at.. -F-� [6a.smmJ i No7.m 7.II W N Standard Temperature Ratings i_ u't Pe�h°" 15,t6" [i9.2mm1 Sprinkler Max. E9a ion[ ;�.Jtm.nc Classification Temperature Ambient Bulb Color W wmenm.n 1/2'[12.7--) Rating Temp. �T w;u.tm.nt R..4. Adi„atment t, 4 9 p 1/4"[6.351 Ordinary 135-F (57°C) 100°F (38°C) Orange »,FOR FrcioeY NUTUk(FM) E=-wa°'^Ad;atm.nt Ordinary 155°F (68°C) 100`F (38°C) Red 4'-6'poll UM)ERWRWERS IABORATOMES(UL) Intermediate It) 175°F (79°C) 150`F (66°C) Yellow Intermediate 200°F (93°C) 150`F (66°C) Green Fig.9 High(11 286°F(141°C) 225°F(107°C) Blue • Listed by cULus for Quick Response.Approved by FM for Standard Response. fi1 Listed and Certified only by cULus. • Recessed Horizontal sdewall sprinklers are listed Sprinkler Installation Wrench: with cULus for installation of min. 4" (100mm) -to Model 33 R/C Sprinkler Wrench -max.6"(150mm)below ceiling and approved by Sprinkler Identification Number(SIN): R5734 FM for installation of min.4"(100mm)-to-max. 12" (300mm)below ceiling. T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(,, Massachusetts Accredited va uation and ,,Inspection Agency wa Technical Data: Ordering Information m,=4.°me�istl n sale w,iiamg Cones. Date 3+,20,6 Orifice Size:1/2"(15mm) Specify: AppmNmis tl¢md Thread or appmve Size: 1"NPT per ANSI B2.1 1. Sprinkler Type(select one): waese,e a Working Pressure: 175 psi(12 bar) (a) Model F3QR Dry Pendent Nominal K Factor-US/(Metric):5.6/(80) (b)Model F3QR Dry Pendent/HE Product Description (c)Model F30R Dry Recessed FP Pendent Rdiable Model F3QR Dry Sprinklersareguickresporsespri riders (d)Model F3QR Dry Recessed F1 Pendent utilizing a durable 3m m frangible glass bulb. This quick response (e)Model F3QR Dry Concealed Pendent enables these sprinklers to apply water to afire much sooner than (f)Model F30R Dry Horizontal Sidewall standard response sprinklers of the similar temperature rating. (g)Model F3QR Dry Horizontal Sidewall/HB Modell F3QR Dry Sprinklers are intended for use in dry and preac- (h)Model F3QR Dry Recessed FP Horizontal Sidewall tionsystems and in areas subjected tofreezing temperatures,such (i)Model F3QR Dry Recessed F1 Horizontal Sidewall as freezers and unheated portions inside and outside buildings. 2. Sprinkler Temperature Rating. Envirorxne-nts wherein dry sprinklers are ernpIcyed can be cor- 3. Sprinkler Finish. resive.For this reason,Model F3 Sprinklers have a special wax fillet 4. Escutcheon type(F1 or FP). placed in the gap between the cup that supports the bulb and the 5. Cover Plate/Escutcheon Finish. wrenching boss.This wax will not interfere with the operation of the 6. Length: sprinkler, and it prevents contarriinents from entering the internal "A"Dimension(face of tee to face of ceiling or wall)in 1/4" portion of the drop ripple_The wax must not be removed. (6mm)increments. Operation 7. Model F30R Dry Pendent (a) is available without The glass bulb consists of an accurately controlled amount of sprinkler can and escutcheon. special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide Note: fast thermal response.Whent-letemperahae increases su fficienty, 1. The "A" dimension is based on a nominally gauged due to a fire,the bulb shatters allowing operating parts to dear the pipe thread "make-up" of 0.600" (15mm) per ANSI waterway. This enables the inlet seal to rele�air or water and 82.1 [71/2 threads approximately]. subsequently, cause water flaw over the deflector in a uniform 2. All platings and paintings are decorative and intend- spray pattern,controlling orextnguishingthefire. ed for interior use. 5. Model F3QR Dry Horizontal Sidewall Sprinkler "A"Dim. I 2"to 48" 51mm to 1219mm in'/4"(6mm)increments t,1 Standard Temperature Ratings Sprinkler Escutcheon Sprinkler Max. Bronze Brass(3) Classification Temperature Ambient Bulb Color Chrome Plated Chrome Plated Rating Tem . White Polyester r'> White Ordinary 135eF (57°C) 100eF (38eC) Orange (1)Other finishes and colas are available on special order. Ordinary 155eF (68°C) 100OF (38eC) Red Consult factory for details. Intermediate t'I 175*F (79eC) 150°F (66eC) Yellow to cULus Listed as a Corrosion Resistant sprinkler in standard Black or Intermediate 200-F (93eC) 150-F (66eC) Green While High 286OF 14100 225OF 10700 Blue 3t Not available for HB escutcheons. Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. 1 1/z•IM-111-11 (t[Listed and Certified only by cULus. Totot A ll.,ent _ F- r__ - Ceiling ---� _ ---------- { To101 Adimtm t -- 4• [101.60—] Min. f—. — 016ng t 1/4"[31.75-1 — t__1 l J 12'[304AD-1 Mex. E -----— — — T 1/ [ta.7mm] Escuf<heon Adjustment c...."..neon Adlust^•nt' 2'I1O1.00mm7 Min. 1~1 cutc [6.35mm] ,2'(3oa.enmm7 lac 1/2' 12.7mm System Tee ^^1,L Escutcheon AojustmenL Eac�3�n Ae}�,je„e,rt p 3/32• 1'NP7 ` 2 3/32' System Tse f� Is3.tdnm7 1-Nrr { i7 — -- 2-13/84 J-1n- s f (76.2omm) f - --- [3s.eemmJ ptesmm7 [53.98mm] (1/2*OR. Hole i Woll I' 1/4'[6.35mm] 1161e to Wod t-t/4•[31.75mm]Nominol Sprinkler Con Protrusion yynn ProW:nn 'A-Umennon FsaACn°kaoNr Con Dimension i Poiustmam N ind PectBon Adiustment Nominal Position Ronge t,/2•[.t2.7mm7 of Escutcheon Range- 1/4"[-6.35mm] of Escutcheon ,a„� - 1/2'[-12.7mm] rsxsa-o + 1 1/4[+31.75mm] Fig.6 Fig.7 Note: The sprinkler can protrudes 1/4"when escutcheon is In nominal Note: The sprinkler can protrudes 11/4"when escutcheon is to nomi- position. Escutcheon adjustment provides'/4"(-6mm)to +1'/4" nal position. Escutcheon adjustment provides'/"(-12.7mm)to (+32mm)"A"dimension adjustment range. +Y"(+12.7mm)"A"dimension adjustment range. prm er nsta atfon ren :TA­oB­eM3_SpnnKIer Wrench Sprinkler Identification Number(SIN): R5734 Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler 'Aa'Dim. 3112"to 48"(89mm to 1219mm)in 1/4" 6mm increments ca„, - - .n F 3/32 Sprinkler Escutcheon ErudMan n5.1mm1 �-[tot.unmlrn. Bronze Brass Chrome Plated Chrome Plated n� White Polvester(2) White R t'>Other finishes and colors are available on special orders Consult factory for details.Cup remainds unfinished."See page 2" =-- t�1 cULus Listed as a Corrosion Resistant sprinkler in standard Black or tWe�n Mot N. W.1 PopAl'on White. Gxv ch z to/ei wn. tse.3n..1 t/4'[x.357 Eawlchem AOYtlmwR Standard Temperature Ratings w�;°° /=0-1•�1 Adrykmani Rnnp. Esvldnaa Mlasfmanl Sprinkler Tem- Max. a ['°35—] 1/4-(6351 Classification Bulb Color E—td—A"�b en1 erature Rating Ambient Temp. ox YUU Cr-) Ordinary 135-F (57eC) 100-F (38eC) Orange 6"�R u� � AaoaArowrs[U11 Ordinary 155°F (68eC) 100-F (38eC) Red Fig.8 Intermediate(1) 1750F (79eC) 15D°F (66eC) Yellow Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Intermediate 200-F (93eC) 150-F (66°C) Green Sidewall Sprinkler in walls which have positive pressure in their High['1 286-F 141°0 225*F 107°0 Blue side space. • Listed by cULus for Quick Response. Approved by FM for (1)Listed and Certified only by cULus. Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cULus Sprinkler Installation Wrench: for installation of min.4"(100mm)-to-max.6"(150mm)below Model G3 RIC Sprinkler Wrench ceiling and approved by FM for installation of min.4"(100mm) Sprinkler Identification Number(SIN): R5734 -to-max. 12"(300mm)below ceiling. T.R ARNOI.D A ASSOCIATES.INC. P.O.Box 1081 Etkb n.IN 46514 ute(s) ma«chuselts cretlile0 E"alua antl 4. .nn Ag my na a v"Jul 31,2015 Model F3QR Dry Pendent Concealed Sprinkler "A"Dim. 311="to 48"(89mm to 1219mm)in'/4" 6mm increments ml°t Pt— o°mt.o -- am.<i^.m.mp. CCP Cover Plate"'Finishes") - � - Standard Finishes Special A pplication Finishes rr - Chrome Plated Bright Brass Plated ? 5 sy9 T.. White Black Plated Black Paint Off White 2 t/2 0°F Satin Chrome •A"Wm.n.i°n [67.50mmJ (tt Utilizes the 1/2"cover plate with 3B"total adjustment. c 3/,s (z,Other finishes and colors are available on special order [t47e ] 2 19/54•at.. Consult factory for details. [58.34—] N°min°I Position I Sprinkle r Standard Temperature Ratings °`c° "'°� Cup A by M—by. Sprinkler Max. c Tna Aeacrney Classification Temperature Cover Plate Ambient — c.°9 Rating Temp.Rating Temp 3 11e•[4.7emm] C°•eryal.a0juslmen! Ordinary 135°F (57°C) 135-F (57°C) 100-F (38°C) 3/16 [aJ6mmJ Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) c.—W.Ad'°.,moot Intermediate(') 175°F (79°C) 165°F (74°C) 150°F (66°C) 3fe [ssmm] [ea.,3mmJ Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) High('t 286-F(141°C) 165-F (74°C) 150°F (66°C) Fig.4 Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler brass and recommended for interior applications. in ceilings which have positive pressure in the space above. (')Listed and Certified only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number(SIN):R5714 Model F3QR Dry Recessed F1 Pendent Sprinkler "A"Dim. 31h"to 48" 89mm to 1219mm)in'/a" 6mm increments Finishes`D t^kt P,°w.i°^o�.pt�d 5 rinkler Escutcheon Collar = ,____===r-PryF=�F �p< ��t�� Chrome Plated Chrome Plated Chrome Plated — - i r-1-;�- White Polyester czt White White =_- J� - _ Other finishes and colors are available on special order. System T� Consult factory for details. w cULus Listed as a Corrosion Resistant sprinkler in standard Black or "1/2•°n t•NPr (6S.7tlmm] White. H.a to c rno "A-Dimension (as.zmm] AdJustm°m Range i Standard Temperature Ratings f 1/4- Sprinkler Max. Noni al Position I (23.amm Classification Temperature Ambient Bulb Color °r r'°"tcheon ac°k.—oy Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange iamm] Ordinary 155°F (68°C) 100°F (38°C) Red Exutehaoor"Zi2 I'l Intermediate") 175°F (79°C) 150°F (66°C) Yellow 1/4•[&351 Intermediate 200°F (93°C) 150°F (66°C) Green �°`"`°"Adj-m-t High(') 286°F(141°C) 225°F(107°C) Blue ndJ<�me�tmJ 2 27/32• [72.2mmJ ,dni°o4 ('t Listed and Certified only by cULus. Fig.5 Sprinkler Installation Wrench: T.R ARNOLD&ASSOCIATES,INC. Model G3 R/C Sprinkler Wrench P.O.Box 1081 Sprinkler Identification Number(SIN):R5714 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance 3 with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. Model F3QR Dry Pendent Sprinkler to 48"(51mm to 1219mm)in 1/4"(6mm)increments Finishes"" Standard Temperature Ratings Winkler Escutcheon Sprinkler Max. Bronze Brass[,] Classification Temperature Ambient Bulb Color Chrome Plated Chrome Plated Rating Temp. White Polyester(') White Ordinary 135°F (57°C) 100T (38°C) Orange "]Other finishes and colors are available on special order. Ordinary 155°F (68°C) 100`F (38°C) Red Consult factory for details. Intermediate t'> 175°F (79°C) 150°F (66°C) Yellow m cULus Listed as a Corrosion Resistants sprinkler in standard Black or Intermediate 200°F (93°C) 150-F (66°C) Green White. p High(1) 286°F(141°C) 225°F(107°C) Blue 13)Not available for HB escutcheons. Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. Listed and Certified only by cULus. At—made Pip° ---, -' - i - r— �; •ee..keid.Pip. L i==ce System Tae — SrKem lee 1•NPi rr54.0mm] I -A•M.�. 1/=•L63Snnam 1-rDi'A'Dimcnaon Ncr in Celan Va IYa`e in GI 9 Orrae M]u ( -1/2'(-t2-1/+1 1/4•p31.Brrvn] [4z.5mm] 1 T 1 Adjuebnnd / L 2iSpr 1 1/4'[31.8-1 1' 214 iC.�o:„� 1/1 tfi.9mm] �__ ratty My ExutcnelM --__ Il. Exuta+°on E.Mclwan Gating i ] -LeTi-- Pdjuslmen! '/7 Lt LTmm.] rSn4AKn Mi o4mirl°I Pcai4at S,�Ab Can 1 Eaculchem Nondn°I Poaitian ' Si B' )-1/e•[J1 is"m.] of Exulcbeon [♦t.Jmm) Iort:rel Pracra,an 's/B- [41.Jmm] 1/4• ProlruGnn rrhelaB 3'pis. 2 13164'[JSddrmJ Fig. 1 Fig.2 Note: The sprinkler can protrudes'/4"when escutcheon is in nominal Note: The sprinkler can protrudes 11W when escutcheon is in noml- position. Escutcheon adjustment provides-'/4"(-6mm)to +11A" nal position. Escutcheon adjustment provides'/z"(-12.7mm)to (+32mm)'A"dimension adjustment range. +'/z"(+12.7mm)"A"dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench:Model G3 Sprinkler Wrench Sprinkler Identification Number(SIN): R5714 Model F3QR Dry Recessed FP Pendent Sprinkler to 48" 89mm to 1219mm in 14" 6rnm)increments Inlet Protrusion D�mt°d =_=�r �i-= r- yc- (1) Above Inside Pipet ' SDri kler Escutcheon Bronze Brass ; Chrome Plated Chrome Plated sysirn Tee White Polyester White 2 1/2"Dio. 1•NPi (1)Other finishes and colors are available on special order. [63.SOmm) Consult factory for details.Cup remainds unfinished. A-aTe",;pn N°Ie in ceiling AdjustmoM Range Only the escutcheon will contain desired finish. t114 19/64"Di°. m cULus Listed as a Corrosion Resistant sprinkler in standard Black or [f6.35mm] [sa_34mm) White. N, no[ Position Sprinkler Standard Temperature Ratings pt Escutcnecn Cup Assembly Sprinkler Max. Classification Temperature Ambient Bulb Color I -wir Esenene°" }R atin Tem `--- g Ordinary 135°F (57°C) 100`F (38°C) Orange 1/4.[6.35mm)Ordinary 155°F (68°C) 100OF (38°C) Red Escutcheon Adjustment Intermediate(1) 175°F (79°C) 150`F (66°C) Yellow 1/4'[6.35mm] 3 7/32 Intermediate 200°F (93°C) 150`F (66°C) Green Eseuteheon Adjustment [B"6mm) High I" 286°F 141°C 225`F 107°C Blue rota Adjustment 157FW2-C Sprinkler cup and FP Escutcheon fabricated of steel and recommended Fig.3 for interior applications. Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprin- L']Listed and Certified only by cULus. kler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench 7.R ARNOLD.AS Box 1081 1081 P.O. FS,INC. Sprinkler Identification Number(SIN): R5714 Elkbrt,IN U514 Suletsl Massachusetts A¢redited E-1—nn and 2. inspenion Agency Dalen sine Jul J1,2015 spn".a d nn Mwvian am Bulletin 157 Rev.H CD ® Model F3QR Quick Response cn Dry Sprinklers Features 1. The Model F3QR sprinkler utilizes Belleville Spring ` Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent Pendent Pendent/HB • Concealed • Horizontal Sidewall (See Fig. 1) (See Fig.2) • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 11/2"(38mm)escutcheon adjustment on pendent sprinkler. 4. 1/2" (13mm)escutcheon adjustment on recessed sprin- kler with push-on/thread-off FP Model Escutcheon ring. , 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push-on/thread-off CCP Cover Plate. ° 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. Recessed FP Pendent Concealed 7. Attractive appearance. Employs 3mm frangible glass S Fi bulb and galvanized nipple. (See g 3) (See Fig.4) 8. Lengths available to accommodate installation di- mensions from 2" -to -48" (51 mm -to - 1219mm), in '/4"(6mm) increments. 9. Available in a variety of plated and painted finishes. 10.Polyester Coated Corrosion Resistant Sprinklers. US Patent Numbers 5,775,431 and 5,967,240. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Cer- Recessed F1 Pendent Horizontal Sidewall tified for Canada (cULus) (See Fig. 5) (See Fig.6) Sprinkler Hazard T.R ARNOLD&ASSOCIATES,INC. Style Response System i a P.O.so.1081 Pendent Elkhart,IN 46514 -, Recessed Pendent Wet Pipe State(s) Massachusetts Recessed F1 Pendent Quick D Pie Light Accredited Evaluation Agency and Cry Pipe Inspection Agency CCP Concealed All Preaction IN,d..—.,,­&d °1­ 115714 �h St-6u.N 9 Date Jul 31,2015 Horizontal Sidewall Wet Pipe ".—I °° d.,�° Recessed Horizontal Sidewall Quick Dry Pipe Light ""r"°"°"°°°p see '"°'"°°°' Horizontal Sidewall/HB 115734 All Preaction (See Fig.7) 2. erti ied by F Approvals Style Sprinkler Hazard tY Response P p System T ype - Light Pendent Wet Pipe Ordinary, Recessed F1 Pendent Quick Dry Pipe Groups (115714) All Preaction i&2 Horizontal Sidewall Wet Pipe Recessed F1 Horizontal Sidewall Quick Dry Pipe Light Recessed FP Recessed F1 (115734) All Preaction Horizontal Sidewall Horizontal Sidewall 3. N C MEA 258-93-E (See Fig. 8) (See Fig. 9) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers Sprinkler emergency cabinets • Dry automatic sprinklers Sprinkler wrenches • Intermediate level sprinklers Sprinkler escutcheons and guards • Open sprinklers Inspectors test connections • Spray nozzles Sight drains • Alarm valves is Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches is Identification signs • Water flow detectors • Fire department connection T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This documetrc is c ffinn as Doing in contormance wkh State Building Codes. Date Jul 31,2015 Approval of this doeumem ace aumo,i�e of appmv any-- n deviation from the mquir menus of e cable State Laws. The equipment presented in this bulletin is to be installed In accordance with the latest pertinent Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or ether similar organizatiors and also with the provisions of governmental codes or ordinances,whenever applicable. Products manufactured and distributed by RELMLE have been protecting life and propertyfor ester 130 years,and are installed and serviced bythe most highly qualified and reputable sprinlder contractors located throughout the United States,Canada and foreign countries. Manufactured by 1i"ab ® The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices Recycled Re (800)848-6051 Sales Far. �Paper le (914)829-2042 Corporate Offices Revision lines indicate updated or new data. xww.r 4ablesprir>I r.co n Internet Adcress EG.Printed in U.S.A.65108 PIN 9999970322 Model F1 Res 44 & 58 Horizontal Sidewall Model F1 Res 76 Recessed Pendent/F1, Sprinkler Model F1 Res 76 Recessed Pendent/F2, Sprinklers shall be[cULus Listed] [New York City MEA Model F1 Res 76 Recessed Pendent/FP Approved (258-93-E)] low flow residential horizontal Sprinklers shall be [cULus Listed] low flow residential sidewall sprinklers engineered to provide a minimum recessed pendent sprinklers engineer 5d to provide a design density of 0.10 gpm/ft2 over the listed coverage minimum design density of 0.10 gpm/ft�over the listed area. Listed flows as specified by the manufacturer's coverage area. Listed flows as specified by the technical data sheets are to be used. Residential manufacturer's technical data sheets are to be used. sprinklers shall be installed in conformance with the Residential sprinklers shall be installed in conformance manufacturer's installation guidelines and the applicable with the manufacturer's installation guidelines and the installation standard. Where horizontal sidewall applicable installation standard. Sprinkler frame and residential sprinklers are installed under sloped ceilings deflector shall be of bronze frame construction having a having a pitch of up to [4/12] [8/12], the sprinklers shall �`a" NPT thread. Water seal assembly shall consist of a be listed for such use.Sprinkler frame and deflector shall Teflon-coated Belleville spring washer and machined be of bronze frame construction having a'/2"NPT thread. cup with 3 mm glass bulb containing no plastic parts,and Water seal assembly shall consist of a Teflon-coated having a temperature rating of [155•F (68•C)] [175•F Belleville spring washer and top-loaded extruded cup (79•C)]. Sprinklers shall have a nominal K-factor of 7.6. with 3 mm glass bulb containing no plastic parts, and Standard finish: [Bronze] [Chrome-plated] [White having a temperature rating of [155•F (68•C)] [175•F Polyester] [Special finish— specify], Recessed (79•C�]. Sprinklers shall have a nominal K-factor of 5.8. escutcheon assembly shall be a steel, two-piece Standard finish: [Bronze] [Chrome-plated] [White escutcheon [with '/2" adjustment (Model F2)] [with 3/" Polyester][Special finish—specify].Residential horizontal adjustment(Model F1)][of push-on and thread off design sidewall sprinklers shall be Reliable Model F1 Res 58, with 1/2"adjustment(Model FP)]. Standard finish shall be SIN R3513(Bulletin 135). [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable[Model F1 Model F1 Res 44 & 58 Recessed Res 76 Recessed Pendent/F1] [Model F1 Res 76 Horizontal sidewall Sprinkler Recessed Pendent/F2] [Model F1 Res 76 Recessed P Pendent/FP] SIN 87618(Bulletin 135). Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Model F1 Res 7fi CCP Pendent (Concealed) Replace "horizontal sidewall sprinkler" with "recessed d) horizontal sprinkler." Add: Recessed escutcheon Sprinklers shall be [cULus Listed] low flow residential assembly shall be a steel,two-piece escutcheon with 1/2" concealed sprinklers engineered to provide a minimum adjustment (Model F2). Standard finish shall be design density of 0.10gpm/0 over"he listed coverage area. [brass][bright chrome] [white painted] [Special finish— Listed flows as specified by the manufacturer's technical specify]. Residential recessed horizontal sidewall data sheets are to be used. Residential sprinklers shall be sprinklers shall be Reliable Model F1 Res 58/F2, SIN installed in conformance with the manufacturer's installation R3513 (Bulletin 135). guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame Model F1 Res 76 Pendent construction having a3/4"NPT thread. Water seal assembly Sprinklers shall be cULus Listed low flow residential shall consist of a Teflon-coated Belleville spring washer and P [ ] machined cup with 3 mm glass bulb containing no plastic pendent sprinklers engineered to provide a minimum parts, and having a temperature rating of 155•F (68•C). design density of 0.10 gpm/ft over the listed coverage area. Cover plate assembly shall consist of a brass cover plate Listed flows as specified by the manufacturer's technical and copper alloy retainer flange. Method of attaching the data sheets are to be used. Residential sprinklers shall be cover plate to the sprinkler cup shall be a push-on and installed in conformance with the manufacturer's installation thread-off design allowing a Yz" cover plate adjustment. guidelines and the applicable installation standard. Cover plate temperature rating shall be 135•F(57•C). A Sprinkler frame and deflector shall be of bronze frame plastic protective cap shall be provided and factory installed construction having a 3/4'NPT thread. Water seal assembly inside the sprinkler cup to protect the sprinkler from shall consist of a Teflon-coated Belleville spring washer and damage,which could occur during construction before the machined cup with 3 mm glass bulb containing no plastic cover plate is installed. Standard cover plate finish: [White] arts, and having a temperature rating of [155•F (68•C)] [Custom Color—specify]. ]. Concealed pendent sprinklers parts, (79•C)]. Sprinklers shall have a nominal K-factor of shall be Reliable Model F1 Res 76 CCP,SIN R7618(Bulletin 7.6. Standard finish: [Bronze] [Chrome-plated] [White 135) Polyester] [Special finish— specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. 11. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of a IicaDle State Laws. Maintenance Model F1 Res 49, F1 Res 58 & F1 Res 76 Sprinklers Model F1 Res 49 & 58 Recessed Pendent/F1, should be inspected quarterly, and the sprinkler system Model F1 Res 49 & 58 Recessed Pendent/F2, maintained in accordance with NFPA 25, 13, 13D, and Model F1 Res 49 & 58 Recessed Pendent/FP 13R. Do not clean sprinkler with soap and water,Ammonia Sprinklers shall be [cULus Listed] [New York City MEA or any other cleaning fluids. Remove dust by using a soft Approved (258-93-E)] low flow residential recessed brush or gentle vacuuming. Remove any sprinkler which pendent sprinklers engineee�red to provide a minimum has been painted(other than factory applied)or damaged design density of 0.10 gpm/ft`over the listed coverage area. in any way. A stock of spare sprinklers should be Listed flows as specified by the manufacturer's technical maintained to allow quick replacement of damaged or data sheets are to be used. Residential sprinklers shall be operated sprinklers. Prior to installation, sprinklers should installed in conformance with the manufacturer's installation remain in the original cartons and packaging until used. guidelines and the applicable installation standard. Where This will minimize the potential for damage to sprinklers that pendent residential sprinklers are installed under sloped could cause improper operation or non-operation. ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance Model F1 RES 49 Residential listina shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" Sprinkler Specifications NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm glass bulb comaining no plastic Model F1 Res 49 & 58 Pendent parts, and having a temperature rating of [155•F (68•C)] Sprinklers shall be [cULus Listed] [New York City MEA [175-F(79•C)]. Sprinklers shall have a nominal K-factor of Approved (258-93-E)] low flow residential pendent 4.9(70). Standard finish: [Bronze] [Chrome-plated][White sprinklers engineered to provide a minimum design Polyester] [Special finish—specify]. Recessed escutcheon density of 0.10 gpm/0 over the listed coverage area assembly shall be a steel, two-piece escutcheon [with 3/2" Listed flows as specified y ified b the manufacturer's technical adjustment(Model F2)][with /� adjustment(Model F1)][of data sheets are to be used. Residential sprinklers shall be push-on and thread off design with 1/2" adjustment(Model installed in conformance with the manufacturer's FP)].Standard finish shall be[brass][bright chrome][white installation guidelines and the applicable installation painted]. Residential recessed pendent sprinklers shall be standard. Where pendent residential sprinklers are Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1] installed undersloped ceilings having a pitch of up to[4/12] [Model F1 Res 49&58 Recessed Pendent/F2] [Model F1 [8112], the sprinklers shall be listed for such use. Res 49 &58 Recessed Pendent/FP] SIN R3516& R3513 Deflector-to-ceiling distance listing shall be 1" to 8" (Bulletin 135). maximum.Sprinkler frame and deflector shall be of bronze Model F1 Res 49&58 CCP Pendent(Concealed) frame construction having a'/Z" NPT thread. Water seal Sprinklers shall be[cULus Listed] [New York City MEA assembly shall consist of a Teflon-coated Belleville spring Approved 258-93-E low flow residential concealed washer and top-loaded extruded cup with 3 mm glass bulb pP ( )] sprinklers engineered to provide a minimum design containing no plastic parts, and having a temperature 2 rating of [155•F (68•C)] [175•F (79•C)]. Sprinklers shall density of 0.10 gpm over the listed coverage area. have a nominal K-factor of 4.9 & 5.8. Standard finish: Listed flows as specified by the manufacturer's technical [Bronze][Chrome-plated][White Polyester][Special finish— data sheets are to specify]. Residential pendent sprinklers shall be Reliable n installed in conformance with the manufacturer's be used. Residential sprinklers shall i Model F1 Res 49&58,SIN R3516&R3513(Bulletin 135). installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch of up to [4/12] [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a '/z" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer and top-loaded extruded cup with 3 mm T.R ARNOLD&ASSOCIATES,INC. glass bulb containing no plastic parts, and having a P.O.sox 1081 temperature rating of 155•F (68•C). Cover plate Elkhart,IN 46514 assembly shall consist of a brass cover plate and copper Massachusetts alloy retainer flange. Method of artaching the cover plate State(s) to the sprinkler cup shall be a push-on and thread-off Accredited Evaluation and design allowing a 112" cover plate adjustment. Cover Inspection Agency plate temperature rating shall be 135•F(57•C). A plastic This document is certified as being in conformance protective cap shall be provided and factory installed with state Building Codes. Inside the sprinkler cup to protect the sprinkler from Date Jul 31,2015 damage, which could occur during construction before Approval of this document does not authorize or approve the cover plate is installed. Standard cover plate finish: any omission or deviation from the requirements of [White] [Custom Color—specify]. ]. Concealed pendent applicable state Lavis. sprinklers shall be Reliable Model F1 Res 49&58 CCP, SIN R3516&R3513(Bulletin 135). 10. Technical Data: F1 Res 58 HSW& HSWIF2 Escutcheon, F2, Data: Norniral T � ( Max. Max. Spr�kler Ad t Face of Fining Thread Odke p I pressure �lertt K I Type I�� two wall) Size Inch Ra J�i T 1 Factor (� °F °C I loar•) cF �36C68 ) I F2 , 13 a -" •(4.7-17.4 /2-NPT Y2•(13) 155 68 175(12) 100 5.8 2.45(62) (R I/2) 175 79 150 *Baseline flows and pressures for 0.05 density Max Sprinkler A,r SpriklerTernp- Flow pyre Spritkler ft Inch Tv Ra (j psi(bar} Mun beer(SIR Inch �� 12 x 12 3.6x3.6 155(68) 175 79 16 60.6 7.6(0.53) ! 14 x 14 4.3x4.3 155 68 01775(79) 1 B 68.2 9.7 0.67 16 x 16 4.9x4.9 4-6 155 68 21(79.5 13.2(0.91) (101-152)16 x 18 4.9x5.5 155(68 25 94.7 18.6 1.28 16x20 4.9x6.1 155 68 29 109.8 25 1.73 i R3533 12 x 12 3.6x3.6 155 68 22(83.3) 14.4(1.0) 14 x 14 4.3x4.3) 6-12 155(68) 22(83.3 14.4 1.0 I 16 x 16(4.9x4.9 (152-305) 155 68 175(79)_ 26 98.4 20.1 1.39 I 16 x 18 4.9x5.5 155(68) 1 175 79 31 117.4 28.6 1.97 'Calculate for a 10 density but in no case go below the baseline flows&pressures Finishes(') Ordering Information Standard Finishes Specify. Sprinkler F1,F2,FP Escutcheons 1. Sprinkler Model Bronze ( Brass Chrome Plated Bright Chrome Plated 2. Sprinkler Type White Pol ester Coated White Painted 3.Temperature Rating Special Application Finishes 4. Sprinkler Finish Sprinkler F1,F2, Escutcheons 5. Escutcheon Finish Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome " Other finishes and colors are available on special order. T.R ARNOLD&ASSOCIATES,INC. Consult factory for details. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of a livable State Laws. 9. • Model F1 Res 44 SWC f 4"t. }2" ...,... C1ur.6CYnrn ro r 114'fit.7-- n2 eenrmwn Jas.aa, ] rMe a ntfrry PUSH ON CopER ThrN T.NO A'—rkn 7lA9Y TO ADAIST UNIX yrer...- 77Rir AG4w'Sr W4LL I-x:12'Rpd—.. i _1t Recormended ,Tn r� f f Ab/. 2 5/i6' , 2 5 18' [Sa.7a,.,rnl I"14r 1 _ 1 _ 7t.t4N oac4z uroix i' ncTrr A"NST sPRF47fLEP. 14mic"Boss r76FN7 712'(12.701"7 Adjusirrmi F1 RES 44 SWC Fig. 5 Technical Data: F1 Res 44 SWC Nominal Spriirikier CMWTM41 Max Max SLpdidde�r Thread Orifice Temp. �9 Ptes!4n AntbiertTemp. K t>dI Inch Radig Factor S� (rnm) IF °c °F I °C (rar? °F °C (mm) 1/2•NPT ^(10) 155 68 135 57 175(12) 100 38 4.4 2.45(62) R%2) e *Baseline flows and pressures for 0.05 density Max Sprinkler A Flow Sprinkler S act Ceiling-to- m Pressure Identification ft(M) InDell mm (U'm) Ps'Oar) Number(SIN 12 x 12 3.6x3.6) 13(49.2) 8.7(0.60) 14 x 14 4.3x4.3) 14 53.0) 10.2(0.71) 16 x 16 4.9x4.9 (1141-152) 17 64.3 15.0(1.1 16x18 4.9x5.5) 19(71.8) 18.7(1.13) 16 x 20 4.9x6.1 23 87.1 27.4(l.89) R3531 12 x 12 3.6x3.6) 14 52.9 10.2(0.71) 14 x 14 4.3x.4.3) 6-12 15(56.7) 1 11.7 0.81 16 x 16 4.9x4.9 (152-305) 18 63.1 16.8 1.16) T.R ARNOLD&ASSOCIATES,INC. 16 x 18 4.9x5.5) 20(75.6) 20.7 1.43) P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and *Calculate for a.10 density but in no case go below the baseline flows&pressures Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. 8. • Model F1 Res 44 &58 HSW Model F1 Res 44 &58 Recessed HSW/F2 ..t tt`:? F2 escutcheon,y (13mm) ntt adjustme Technical Data: F1 Res 44 HSW & HSW/F2 Escutcheon, F2, Data: Nominal Sprry Max Max ace of Fmirg 1" ��' A�justrrrerrt Thread Orifice Prew.m Ambient K UNIEP Type Inch(mm) to wall Sm Inch 119 T Factlor trh Intl mm (mm) IF �C (bar) IF I °C (mm) F2 13) = - 4.7-17.4) yr NPT Y'.(i 0) 155 6$ 175(12) 100 3$ 4.4 2,45(62) (R/2 175 79 150 66 *Baseline flows and pressLwes for 0.05 density Max Sprinkler W Sprinkler Te Flow Sprinkler P Celing-to- SP �' g Pressure � S ft(m)9 Deflector F�(°L7 (�Pm) psi(bar) Identification Number(SIM Inch mm 12 x 12(3:6x3.6) 155 68 175(79) 12 45.4) 7.5(0.52) 14 x 14 4.3x4.3) 155(68) 175(79) , 14(53.0) 10.2(0.71) 16 x 16 4.9x.4.9 4-6 155 68 175 79 16 60.6 13.3 0.92 T.R ARNOLD&ASSOCIATES,INC. 16x1$ 4.9x5.5 (101-152) 155(68 175 79 18(68.1) 16.8(l.16) P.O.Box 465 18x 1$ 5.5x5.5 155(68) 175(79) 19 72.0 18.7(l.29) Elkhart,IN huset State(s) Massachusetts 16 x 20 4.9x6.1 155(68) 175(79) 23(87.1) 27.4(l.89) R3531 Accredited Evaluation and 12 x 12 3.6x3.6) 155(68) 1 175 79 14(53.0) 1 10.2 0.7 f) Inspection Agency 14 x 14 4.3x4.3 155 68 175 79 16 60.6 13.3 0.92 6-12 This document is certified as being in conformance 16 X 16 4.9x.4.9 (152 305) 155 68 175(79) 17 64.4 15.0 1.04) with State Building Codes. 16 x i8 4.9x5.5 1-%(68) 175(79) 20(75.7) 20.7(l.43) Date Jul 31,2015 16 x 20 4.9x6.1 155(68) 175(79) 23(87.1) 27.4(1 89) Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. "Calculate for a .10 density but in no case go below the baseline flows&pressures 7. Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent I FP CCP Options Data: Nomilal T Sri* Max Max Spriw "A" "B" Thread p�-�e � T pie Pabient K L�gh Cover Ad'ustment CCP Height Size Inch Rang of psi Ttrrp. Factor inch Inch mm) Inch(m (r� •F •C •F °C #ar) •F •C (nrn) I. 12.7) ,s 24) 4.7 3/1 09) !/2a NPT �e(11) 155 68 1351 57 175(12) 100 38 4.9 257) "Baseline flows and pressures for 0.05 density FP Data "A": Max.Sprinkler Flow Pr�esstre Sprinkler FP Position „A" Spacing Identification I Inch(mm) ft m g:)rn"ryo Psi(bar) Nunber(Sl1i Ma..Recessed ', 11) 12 x 12 3.6x3.6 13 49 7.0(0.48) Min. Recessed I 75, (24 14 x 14 4.3x4.3 13(49) 7.0%0.48 Note: Sprinklers shown in Fig. 3 and Fig. 4 are not 16 x 16 4.9x4.9) 1a(53) 8.2(0.56) 83516 suitable for installation in ceilings which have 18 x 18 5.5x5.5 18 68.1 13,5 0.93 positive pressure in the space above. 20 x 20 6.1x6.1 20 75.7 16.7 1.14 Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Norniral q C{ Max Max Spriida Thread Orifice �?p- Resare Arrt�x K Size Inch IAig Tetp. psi Temp. Factor hd1 (� •F •C •F °C �) •F •C T.R ARNOLD&ASSOCIATES,INC. •R12 '/z(13) 155 68 135 57 175(12) 100 38 5.8 2.25(57)I P.O.Box 1081 Elkhart,IN 46514 "Baseline flows and pressures for 0.05 density State(s) Massachusetts Accredited Evaluation and Max.Sprinkler Flow Pressure Sprrnder Inspection Agency Spacing �n pm) psi ro� k��f c tx►n This document is certified as being in conformance `�i',,, with State Building Codes. 12 x 12 3.6x3.6 16(61) 7.6(0.53) Date Jul 31,2015 14 x 14 43x4.3 16 61 7.6 0.53 Approval of this document does not authorize or approve 16 x 16 4.9x4.9 16 61 7.6(0.53) 83513 any omission or deviation from the requirements of a licable Stale Laws. 18 x 18 5.5x5.5 19(72 10.8(0.75 20 x 20 6.1x6.1 22 83.3 14.4(1.0 Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Nominal Spin e I Max MML Slxiitlerl SM Orifice Anbient K Ler Thread Size �� � Y x � TUT' psi Tip• Factor h h •F •C •F °C raj •F •c /s•NPT I%2 155 68 100 38 2.25 (R3/4) 175 79 135 57 175(12) 150 66 7.6 57) *Baseline flows and pressures for 0.05 density Max.Sprinkler Flow Pressure Spr_v*Ier Spacing ��� psi( klenUfication ft m Ntmtier S 12 x 12 3.6x3.6 21 7.6 0.53 14 x 14 4.3x4.3 21 7.6 0.53 16 x 16 4.9x4.9) 21 7.6 0.53 87618 'Calculate fora.10 density but in no case 18 x 18 5.5x5.5 22 8A 0.58 go'below the baseline flows&pressures 20 x 20(6.1x6.1 25 10.8 0.74 6. T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Technical Data: F1 Res 76 Pendent and Recessed Pendent Inspection Agency This Document is-1..d as being in conformance y w h stare Building Codes, Nominal IVUL Max vilider Date Jul 31,2015 "1"�""' Approval of this tlocummt tices nd authorize or apprw e Thread Orifice Tetrtp pe AMbfft K a Y om,=so a Daviauon hum regal, a is a i applkab state Laws.IFICh Size Inch pa T Facoa� le (mm) •F •C (bar) + •C (nun) Face affrtiirlg to % Technical Data: F1 Res 49 Pendent and Recessed Pendent Escutcheon, F1 or F2, Data: Nominal T Max- Max. �� Sprirnkler pd�t,stment 'IA„ Face�fRting to Thread Orifice �errnp. Ambient K L Type I�(rrm) Inch(rrm) Inch (rrrn Sae Inch } (ffni � °F I `C lam) °F °C Factor ( ) 3 (19.0) Min.=%• {19.1 ,� (4.7 24.0) F1 / Max.=1f,•j38.1 e' s %•NPT 11 155 68 175 12 10 38 4.9 2.25 57 1 RY2) /,e { ) 175 79 { ) 150 66 ( ) F2 )/,(12.7) Max=1 6. 38.8) Y6_711,(4.7-17.4) "Note:Escutcheons F1 or F2 may be used with Model F1 Res 49&58 Recessed Pendent SprinWer "Baseline flows and pressures for 0.05 density Deflector-to-ceihtx� *Deflector-to-celli Max num 1"(25rnn to 4'(1OOrnm) MaAmum 4"(10W N4 to 9'(2O3mni Max.Sprinkler Sprinkler Max.Sprinkler Flow Pressure Sprinkler Flow Pressure Spacing gpm(Lpm) psi(bar) Identification Number I Spacing gpm(Lpm) psi(bar) Identification umber(SN) t m Number SIN t m Number SI 12 x 12 3.6x3.6 13 49 7.0(0.48) 12 x 12(3.6x3.6) 15(57) 9.4 (0.65 14 x 14 4.3x4.3 13 49 7.0 0.48 14 x 14 4.3x4.3 16(60.5) 10.6(0-73) 16 x 16 4.9X4.9 13 49 7.0 0.48 R3516 16 x 16 4.9x4.9 17(64.3) 12.0(0.83) R3516 18 x 18 5.5x5.5 17(64.3) 1 12.0(0.83) 18 x 18(5.5x5.5) 19(721, 15.0(1.0 20 x 20 6.1x6.11 j 20 75.7 16.7 1.14 20 r.20 6.1 x6.1 22(83.2} 20.2(1.4 *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth= 7- (178mm) 2.Beam spacing at or greater than 7.5 ft.(2.3m)on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent Max Nominal Ste' Max. - Sprinkler Thread Orifice imp- Pressure Ambient K Length Size Inch Ra psi T Factor Inch (mm) .F .0 (bar) .F .0 (mm) Yt NPT �•{13) 155 68 175(12) 100 38 5.8 2.25(57) R/2) 175 79 150 66 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 "Baseline flows and pressures for 0.05 density Elkhart,IN 46514 State(s) Massachusetts Max.Sprinkler Flow Ceiling-to- Sprui ler Accredited Evaluation and Spacing Deflector Identification Inspection Agency ft m 9Pm(I P� psi Oar) Nttrrber St This document is certified as being in conformance 12 X 12 3.6X3.6 16 61 7.6(0.53) with State Building Codes. 14 x 14 4.3x4.3 16 61 7.6 0.53 Date Jul 31,2015 16 x 16(4.9x4.9) 16(61) 7.6 0.53 (25-100)4 83513 Approval of this document does not authorize or approve 18 x 18 S.Sx5.5 19 72 10.8 0.75 any omission or deviation from the requirements of applicable State Laws. 20 x 20(6.1 x6.1) 22(83.3) 14.4(l.0) Calculate for a.10 density but in no case go below the baseline flows&pressures 4. Installation Models F1 Res sprinklers are to be installed as use only the Model GFR2 Sprinkler wrench. Use of shown. Model F1, F2 and FP Escutcheons, illustrated wrenches other than those specified may damage herewith,are the only recessed escutcheons to be used these sprinklers. with Model F1 Res sprinklers. Use of any other Note:A'leaktight"sprinklerjointcan be obtained with recessed escutcheon will void all approvals and the following torque: warranties. For installing Model F1 Res Pendent - %4" NPT(R3/4)— 14-20 ft-Ibs(19-27.1 N-m) sprinklers use only the Model D sprinkler Wrench; for - 1/2" NPT(R1/2)—8-18 ft-Ibs(10.8-24.4 N-m) installing Models F1 Res Recessed Pendent, CCP Do not tighten sprinklers over maximum sprinklers use only the Model GFR2 sprinkler wrench; recommended torque. It may cause leakage or for installing Model F1 Res recessed HSW sprinklers impairment of the sprinklers. • Model F1 Res 49, 58 & 76 • Model F1 Res 49, 58 & 76 Pendent Recessed Pendent/F11F2 :O ne ­ZZ� ry F T.R ARNOLD&ASSOCIA ES,INC. P.O.Box 1081 Elkhart,IN 4651 State(s) Massachuse Accredited Evaluation and F1 escutcheon, (19mm) adjustment Inspection Agency 1 his document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Note: See escutcheon table for dimensions. Approval of this tlocume t oes not au a r approve any omission or devi ion from the requirements of lica le State Laws. z t/"IfaF ofl t i RbW�W r"_'Ws;s WRENCY FACE CF 7177.V TO _ t F7 �J7- ire-ryre If"cscuTCr¢vt; fC/�// Yts-tr/re(rz acum�ar) IT3brrm) �. I /J5fG43 7]SFCO2A S zs�]" P­3 Fig. 1 Fig. 2 3. Application Model F1 Res Sprinklers are used for Residential Fire Example_No 1 Protection according to UL 1626 Standard'. Be sure Room Size= 12 it x 20 it(3.6 m x 6.1 m) that orifice size, temperature rating, deflector style and Coverage Area= 12 x 20=240 It'(22.3 m2) sprinkler type are in accordance with the latest Flow @ 0.10 gpm/ft2 density=240 x 0.10= 24 gpm published standards of The National Fire Protection Using an F1 Res 49 Pendent Sprinkler, K=4.9 Association or the approving authority having Pressure= (24/4.9)2= 24 psi (1.65 bar) jurisdiction. The baseline flow for a 20 it x 20 it (6.1 m x 6.1 m) When using F1 Residential Sprinklers for systems coverage area using the baseline density of 0.05 design to NFPA 13D or NFPA 13R, use listed area of gpm/ftrwill be 20 gpm @ 16.7 psi (75.7 Umin @ 1.14 coverage and minimum flow and pressure requirements bar). Therefore,the minimum flow required is 24 gpm @ shown in Bulletin 135. 24 psi(90.8 Umin @ 1.65 bar). For systems designed to NFPA 13, use information in this bulletin.The numberof design sprinklers shall be the Example No. 2 most hydraulically demanding sprinklers as required by Room Size=8 ft x 20 ft(2.4 m x 6.1 m) NFPA 13. Rows and pressures can not be below the z baseline flows and pressurers. Coverage Area= 8 2 20 = 160 ft2(14.9 m } NFPA 13 Flow @ 0.10 gpm/ft density= 160 x 0.10= 16 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 For residential sprinkler systemrr7,s designed to NFPA 13, Pressure= (16/4.9)2= 10.7 psi (0.74 bar) a minimum density of 0.1 gpm/ft`must be provided over The baseline flow for a 20 it x 20 ft (6.1 m x 6.1 m) the"design area"that includes the four(4)hydraulically coveragge area using the baseline density of 0.05 most demanding sprinklers for the actual coverage areas being protected by the 4 sprinklers. The minimum gpm/f? will be 20 gpm @ 16.7 psi quire is 2 g m @ required discharge from each of the four most bar}.psi (75.7 L/me minimum bar). required is 20 gpm @ hydraulically demanding sprinklers shall be the greater 16.7 psi (75.7 Umin @ 1.14 bar). of the following: 1.The flow rates given in the Reliable Residential Example No 8 Sprinkler Technical Bulletins referenced in Table A Room Size= 10 it x 16 it(3.0 m x 4.91 m) for NFPA 13D and 13R as a function of temperature Coverage Area= 10 x 16= 160 ft (14.9 m2) rating and maximum allowable coverage area (for Flow @ 0.10 gpm/ft2 density= 160 x 0.10= 16 gpm actual coverage areas less than or between those Using an F1 Res 76 Pendent Sprinkler, K=7.6 indicated in the respective technical bulletin, it is The baseline flow for a 16 it x 16 it coverage area is 21 required to use the minimum required flow for the gpm @ 7.6 psi (79.5 Umin @ 0.52 bar). Therefore, the next largest coverage area);or minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 2.A minimum discharge density of 0.1 gpm/ft2 L/min @ 0.52 bar). applied over the"design area"consisting of the four most hydraulically demanding sprinklers for the Example No. 4 actual coverage areas being protected by the four Room Size= 14 it x 18 it(4.3 m x 5.5 m) sprinklers. The maximum dimension of the actual 2 2 Coverage Area= 14 x 18= 252 it (23.6 M2) coverage area cannot be any greater than the z maximum coverage area indicated in the technical Flow @ 0.10 gpm/it density= 252 x 0.10 = 25.2 gpm bulletins referenced in Table A. (94.6 Umin) Design Note: Using the AS = S x L method to Using F1 Res 76 Pendent Sprinkler, K=7.6 determine the sprinkler protection area of coverag Pressure= (252(7,6) = 11 psi (0.76 bar) in accordance with NFPA 13,apply the 0.1 gpm/ft9 The baseline flow and pressure of an 18 it x 18 ft density to this area to determine the minimum coverage area is 21 gpm @ 7.6 psi (79.5 Umin @ 0.52 required flo Compare this flow to the minimum bar). Therefore, the minimum flow and pressure is 25.2 0.05 gpm/fKULus Listed flow for the appropriate gpm @ 11 psi (94.6 L/min @ 0.76 bar). coverage area in the technical bulletin for the specific residential sprinkler. If the flow stated in the in general residential sprinklers require techni al bulletin is less than the calculated 0.1 flows and pressures as listed for 0.05 gpm/ft4 density flow required, the .1 density flow densities to achieve the proper spray pattern must then be used in the equation Q=KJP,solving so the flows and pressures at 0.05 density are for P, to establish the minimum required pressure the baseline flows and ressures. Flows and using the sprinkler K-factor. Note: In many cases pressures below the listed 0.05 density shall the listed flow of individual residential sprinkler� not be used. may exceed the required minimum 0.05 gpm/ft density.Reliable has available residential sprinklers T.R ARNOLD&ASSOCIATES,INC. with larger K-factors (K=5.8 and K=7.6) that wil� provide lower pressure demands for 0.1 gpm/ft P.O. ,I 465 densities in NFPA 13 residential applications. Elkhart, sa huset State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. 2. Date JuI 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. Bulletin 176 Rev.A UD Model F1 Residential Sprinklers for Design Density of .10 gpm/fe D Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of A5 gpm1ft2 Types: " w 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F 1 3. F1 Res 49 Recessed Pendent/FP 4. F1 Res 49 CCP Pendent 5. F1 Res 58 Pendent F1 Res49,58&76 F1 Res 49,58&76 6. F1 Res 58 Recessed Pendent/F1 Recessed Pendent/F1 Recessed Pendent/FP 7. F1 Res 58 Recessed Pendent/FP 8. F1 Res 58 CCP Pendent 9. F1 Res 44&58 HSW _ ir 10. F1 Res 44&58 HSW Recessed HSW/F2 =` 11. F1 Res 44 SWC 12. F1 Res 76 Pendent fi 13. F1 Res 76 Recessed Pendent/F 1 z �Er 14. F1 Res 76 Recessed Pendent/FP - 15. F1 Res 76 CCP Pendent F1 Res 49,58&76 F1 Res 44&58 CCP Pendent Recessed HSW/F2 Listings&Approvals T.R ARNOLD&ASSOCIATES,INC. 1. Listed by Underwriters Laboratories Inc. and P.O.sox loss UL Certified for Canada (cULus) 2, NYC MEA 258-93-E Elkhart,IN 46514 State(-s) Massachusetts . UL Listing Category Accredited Evaluation and Residential Automatic Sprinkler Inspection Agency UL Guide Number with document is certified as being in conformance with State Budding Codes. F1 Res 44 SWC VKKW Date Jul 31,2015 Patents Approval of this document does not authorise or approve any omission or deviation from the requirements of US Patent No.6,516,893 applies to the applicable State Laws. Model F1 Res 49&58 Pendent Sprinklers Product Description Technical Data: Model F1 Res Pendent sprinklers (Figs. 1, 2, 3 & 4) • Thermal Sensor. Nominal 3mm glass-bulb combine excellent durability, high sensitivity glass-bulb • Sprinkler Frame:Brass Casting and low profile decorative design. • Sprinklers'Pressure Rating: 175 psi The 3mm glass-bulb pendent sprinklers permit the Factory Hydrostatically Tested to 500 psi efficient use of residential water supplies for sprinkler . Thread Size: ;,12"NPT(R1/2) coverage in residential fire protection design. • Kfactor 49(Ac,a)-F1 Res 49 Per&ef1 Sprirfda- The low flow F1 Res sprinklers are specially 5.8(Actual)-F1 Res 58 Paxlent HSVVqyinklff engineered for fast thermal response to meet the 7.6 Actual)-F1 Res 76 Pendent SprnkWl sensitive fire protection application needs of the latest 4.4 Actual)-F1 Res 44 HSW Sprinkler I residential market standards(UL 1626 Standard '). • Density: Minimum 0.10 gprW Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. . Effective date 7/12/02 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable Slate laws. SPEARS*MANUFACTURING COMPANY ,T1 T146 Corporate Office .r 15853 Olden Street•Sylmar,CA 91342 [FMO= PO Box 9203•Sylmar,CA 91392 (818)364-1611•hV:1Avm.spearsmfg.com 0 Copyright 2010 Spears°Manufacturing Gornparry.All Rights Reserved.Printed in the United States ofAmerica 02110. FG-40210 FlameGuard" CPVC FIRE SPRINKLER PIPING PRODUCTS TRANSITION UNION T.R ARNOLD&ASSOCIATES,INC. Brass Thread Insert Stolle P.O.Box 1081 Socket Fipt Elkhart,IN 46514 ` State(s) Massachusetts jl Accredited Evaluation and Inspection Agency NUT M This document is certified as being in conformance 0-D• with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of N apelicable State Laws. L Part Number Size L M N Nut O.D. Approx.WL(Lbs.) 4259-010BR 1 2-13/16 1-7/8 1-1132 2-7/8 .52 4259-012BR 1-1/4 3 2-3116 1-1/8 3-9132 .98 4259-015BR 1-1/2 3.3/4 2-1/2 1-9/16 3-17/32 .93 4259-02DBR 2 3.5/8 2-7/8 1-1/4 4-5116 1.64 Not intended to convey or dispense water for human consumption through drinking or cooking SOCKET DIMENSIONS SCH 40-ASTM F438 SCH 80-ASTM F439 N--C t : 1 1 B A Size Socket Socket Tolerance SCH 40 Minimum SCH 80 Minimum Entrance A Bottom B Socket Length C Socket Length C 3/4 1.058 1.046 t.004 .719 1.000 1 1.325 1.130 ±.005 .875 1.125 1-1/4 1.670 1.655 ±.005 .938 1.250 1-12 1.912 1.894 ±.006 1.094 1.375 2 2.387 2.369 ±.005 1.156 1.500 2-1/2 2.889 2.868 t.007 1.750 1.750 3 3.516 3.492 t.008 1.815 1.875 23 SPEARS@ MANUFACTURING COMPANY FlameGuard" CPVC FIRE SPRINKLER PIPING PRODUCTS FLANGE - TWO PIECE Van Stone Style,4 Bolt Holes,175 psi Socket M --'1 LfR t 16 Ti 111j i N-#I Imo—BOLT CIRCLE DIA.—► MAX O.D. Bolt Circle i No.of Bolt Min.Bolt Part Number Size L M N R Dia. Holes Bolt Size Length Max.O.D. Approx.Wt.(Lbs.) 4254-030 3 2-1/8 4-1/4 9132 1-1132 6 4 518 3-1/4 7-15/32 1.75 FLANGE -TWO PIECE Van Stone Style,4 Bolt Holes,175 psi Spigot pIPE 0 D. 4 N L R "�CfR�ff Bolt No.of Bolt Min.Bolt Max. Part Number Size L N R Circle Bolt Size Length O.D. Approx.Wt.(Lbs.) Dia. Holes 4256-007 314 1-15!16 13116 17132 2-314 4 12 2 3-27132 .30 4256-010 1 2-7132 1-1132 11116 3-1/8 4 V2 2-1/4 4-1/4 .41 4256-012 1-114 2-318 1 11116 1 3-1/2 4 1 12 2-1/4 45x8 .50 4256015 1-12 2-7116 1-3132 23132 3-7/8 4 12 2-12 4-31132 .65 4256020 2 2-314 1-5132 25132 4-3/4 4 518 3 5-15116 1.00 4256025 2-12 3-1/16 1-9132 1-1/32 5-1/2 4 58 3-1/4 6-15116 1.62 4256030 3 346 1-13/32 1-1/32 6 4 58 1 3.1/4 7-9116 1.76 UNION T.R ARNOLD&ASSOCIATES,INC. Socket x Socket P.O.sox 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and NUT Inspection Agency 00. fv; This document Is cended as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this or deviation does not authorize ne approve r, ary omission or deviation from the requirements of Ikaud State Laws. L Part Number Size L M N Nut O.D. Approx.Wt.(Lbs.) 4257-007 314 2-3/8 1-17132 Na 2-1/2 .38 4257-010 1 2416 1-27/32 318 2-718 .41 4257-012 1-114 2-27132 2-7132 11/32 3-5116 .52 4257-015 1-112 3-1/8 2-12 3/8 3-17132 .63 4257-020 2 3.5/8 3-1132 9/16 4-3116 1.09 MADE IN THE U.S.A. 22 FlameGuard" CPVC FIRE SPRINKLER PIPING PRODUCTS TEST PLUG T.R ARNOLD&ASSOCIATES,INC. (PVC White)Not UL Usted;For Pressure Testing Orly, P.O.Box 1081 Mlpt Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency --------- This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or devialion from the requirements of Lill— a licahle State Laws. L—iI Part Number Size L Approx.Wt (LL1___d 4250-005 112 27/32 .02 FLANGE - ONE PIECE 4 Bolt Hdes, 175 psi Socket r--M—►� L Ln N I Ir— BOLT E DI MAX O.D. — — I a— MAX O.D. No.of Bolt Min. Part Number Size L M N R Bolt Circle Bolt Bolt Max. Approx.Wt. Holes Dia. Size Length O.D. (Lbs.) 4251-007 314 1-5132 1-1/2 18 17/32 4 2-3/4 1/2 2 3-29/32 .31 4251-010 1 1-5/16 1-13116 118 11116 4 3-1/8 1/2 2-114 4-9/32 .35 4251-012 1-1/4 1-13f32 2-7132 5132 11/16 4 3-1/2 1/2 2-1/4 4-5/8 .44 4251-015 1-112 1-9/16 2-112 3116 23/32 4 3-718 112 2-112 5 .52 4251-020 2 1-27/32 3 5116 27/32 4 4.3/4 518 3 5-31/32 .95 4251-025 2-1/2 2-7/32 3-1/2 7116 1-1/32 4 5-1/2 5/8 3-114 7 1.50 BLIND FLANGE 4 Bolt Holes, 175 psi rR F+- BOUT CIRCLE DA D _yl Part Number Size R Bolt No.of Bolt Bolt Size Min.Bolt Max.O.D. Approx.Wt.(Lbs.) Circle Dia. Holes Length 4253-007 3/4 17/32 2.314 4 1/2 2 3-27/32 .30 4253-010 1 23/32 3-18 4 112 2-1/4 4-114 .35 4253-012 1-1/4 21/32 3-1/2 4 112 2-1/4 4-5/8 .40 4253-015 1-1/2 314 3-78 4 112 2-1/2 5-1132 .74 4253-020 2 27132 4-314 4 518 3 5-31/32 .86 4253-025 2-1/2 1-1132 5.1/2 4 518 3-1/4 6-15/16 1.70 4253-030 3 1-5116 6 4 58 3-1/4 7-58 1.72 21 SPEARS'MANUFACTURING COMPANY FlameGuard TM CPVC FIRE SPRINKLER PIPING PRODUCTS CAP T.R ARNOLD&ASSOCIATES,I NC. Socket P.O.sox 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and M Inspection Agency This document is certified as being in conform nce with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or a rove any omission or deviation from me requirement of w a licable Slate Laws. Part Number Size M W Approx.Wt.(Lbs.) 4247-007 314 1-3/8 1-13!32 .05 4247-010 1 1-5/8 1-19132 .06 4247-012 11/4 2-3/32 1-27/32 .13 4247-015 1-1/2 2-11132 2 .17 4247-020 2 2-27132 2432 .39 4247-025 2-112 3-17132 2-516 .50 4247-030 3 4-Y8 3 .92 TEST PLUG - 0-ring Sealed Mipt-For Pressure Testing Orly, Not For use with Z4235 Series Adapters L M1 — — --- M 1/2-14 NPT Part Number Size L M M1 Approx.Wt.(Lbs.) FTP-005 V2 1-27132 1-15116 1 7132 .03 TEST PLUG for TorqueSafeTM Gasket Sealed Head Adapters Mipt-For Pressure Testing Ordy. Use ONLY with Gasket Sealed Head Adapters L Nil — — — — M 1/2-14 NPT Part Number Size L M M1 Approx.Wt.(Lbs.) FTP-005GS 1/2 1-25132 2-1132 1-1/4 .05 MADE IN THE U.S.A. 20 [EDMI F CPVC FIRE SPRINKLER PIPING PRODUCTS ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Fipt PIPE Q � r Body F+ L Width N Part Number Size L Q Body Width Approx.Wt.(Lbs.) Min Max Min Max 42004SR 3141/2 5-1132 6-5/16 3-3116 4-15/32 1-5/16 2-1/8 .36 42014SR 1x112 6.7/16 8-1/8 1 4-7/16 6.114 1 1-7/16 1 2-3118 1 .67 INC. REDUCER BUSHING P.O.Box 1081 Flush Style Elkhart,IN 46514 Splgotx Socket State(s) Massachusetts Accredited Evaluation an Inspection Agency This document is certified as being in con( mance PIPE with State Building Codes. O-D. Date Jul 31,2015 Approval of this document does not authorize c approve any omission or deviation from the requirem nts of Ll a icable State Laws. N tJL--J Part Number Size L N Approx.Wt.(Lbs.) 4237-131 1x314 1-1/4 1/4 .04 4237-167 1-1/4x314 1-7/16 7/16 .10 4237-168 1-1/4x1 1-13/32 9132 06 4237-210 1-1/2x314 1-11/16 11/16 .19 4237-211 1-1/20 1-17/32 13132 .15 4237-212 1-1/20-1/4 1-9/16 5/16 .07 4237-248 2x3/4 1-29/32 29/32 .27 4237-249 20 1-29/32 3/4 .25 4237-250 2x1-1/4 1-11/16 7116 .21 4237-251 2x1-112 1-11/16 5/16 .15 4237-290 2-1MI-1/4 2-13/32 1-5/32 .45 4237-291 2-1/2x1-1/2 2-13132 1-1/32 .43 4237-292 2-1/2x2 2-9132 25132 .29 4237-338 3x2 2-1/4 314 .63 4237-339 3x2-1/2 2-5116 1/4 .40 19 SPEARSC'MANUFACTURING COMPANY FlameGuard TM CPVC FIRE SPRINKLER PIPING PRODUCTS IIIIIIIIIIJ BUSHING with BRASS THREAD INSERT TX ARNOLD&ASSOCIATES,INC. Spigot x Apt P.O.Box 1881 �g p ElkhaA,IN 48514 State(s) Massachusetts Accredited Evaluation and PIPE Inspection Agency 2- M O.D. tnrs tlocumem is cenir a as eetrg.n cmt«ma�re .nn stage apiapy cpees. '_; Date Jul 31,2015 Apppval of tM1is tlxum lOO nM auMnm or approve i�uea sae�� Part Number Size L Approx.Wt Lbs. 4238-130SR 1x112 1 .13 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Spigot x SR Apt �— PIPTE - - 1 O.D. bL N gA Part Number Size L M1 N Approx.Wt. Lbs. 4238-101SR 314x1!2 1-29/32 1-7132 1/8 .07 4238-130SR 10/2 2-1f32 1-7/32 7132 .09 MALE ADAPTER --- With CPVC Lined Thread Brass Insert - Mipt x Socket ___— __— M1 i L �.t Part Number Size L M1 N Approx.Wt.(Lbs.) 4236.007 314 2-17/32 1-13132 13/16 .26 4236-010 1 2-15/16 1-23132 29132 .43 4236-012 1-1/4 3-1/8 2-3132 31132 .66 4236-015 1-1/2 3-9132 2-11132 31132 .80 4236-020 2 3.7/16 2-27132 31132 1.07 ADJUSTABLE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Fipt N eody N Part Number Size Min L Max Min Max Q Body Width Approx.Wt.(Lbs.) 42001SR 314x1/2 6-9132 8 47/16 6-114 1-7116 2-3116 .66 42011SR 1x1/2 6-13132 8 4-112 6-1/8 1-7116 1 2-1/8 .68 MADE IN THE U.S.A. 18 FlalmeGuard TM CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE SPRINKLER HEAD ADAPTER T.R ARNOLD&ASSOCIATES,INC. Brass Thread Insert Style with Positioning Ring P.O.Box 1081 Socket x Apt Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance M —'—' M1 with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of a plicable State Laws. L::::N —L Part Number Size L M M1 N Approx.Wt.(Lbs.) R4235-101 3/41/2 2-1132 1-7116 1-3116 15132 .15 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Positioning Ring Socket x SR Fipt M -—-— M1 Part Number Size L M Ml N Approx.Wt.(Lbs.) R4235-t01SR 3/41/2 1-15/16 1-7116 1-7/32 7132 .09 SPIGOT FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Spigot x Fipt PIPE _----_ 1 O.D. L Part Number Size L M1 N Approx.Wt.(Lbs.) 4238-101 314112 1-15/16 1-17132 17/32 .18 4238-130 1x1/2 2-1/4 1-3116 11132 .i9 Not intended to convey or dispense water for human consumption through drinking or cooking 17 SPEARS°MANUFACTURING COMPANY FlameGuard" CPVC FIRE SPRINKLER PIPING PRODUCTS Emil GASKET SEALED FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style T.R ARNOLD&ASSOCIATES,INC. Y P.O.sox 1081 Socket x Gasket Fipt Elkhart,IN 46514 States) Massachusetts Accredited Evaluation and Inspection Agency M -—-— M1 This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of N applicable State Laws. L Part Number Size L M M1 N Approx_Wt.(Lbs.) 4235-130GS 1x112 2.1/32 1-11/16 1-3/e 17/32 .17 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style Socket x Apt +M --- M1 L L Part Number Size L M M1 N Approx.WL(Lbs.) 4235-101 314x112 1-7/8 1-13!32 1-17/32 15132 .19 4235-130 1x112 2-11/32 1-11/16 1-3/16 5/8 .16 4235-131 104 2-5116 1-11116 1-3/8 17/32 .18 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE SPRINKLER HEAD ADAPTER Brass Thread Insert Style with Long Body Socket x Fipt M) --- -- M1 L F� Ni L Part Number Size L M M1 N Approx.Wt.(Lbs.) L4235.130 1x112 2-3116 1-23/32 1-7/32 1/2 .19 Not intended to convey or dispense water for human consumption through drinking or cooking MADE IN THE U.S.A. 16 FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS -Elmi FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread w/Metal Thread Start T.R ARNOLD&ASSOCIATES,INC. p P.O.Box 1081 Socket x SR Apt Elkhart,IN 46514 _ State(s) Massachusetts -N, Accredited Evaluation and Inspection Agency IIIM ---- M1 This document is certified as being in conformance with State Building Codes. Date Jul 2015 not Approval of this document does not authorize or approve any omission or deviation from the requirements of „ L applicable State Laws, Part Number Size L M M1 N Approx.Wt.(Lbs.) Z4235-101SR 314112 1-7/8 1-318 1-7116 3116 .08 SPIGOT FEMALE ADAPTER Brass Thread Insert Style Spigot x Fipt PIPE _____ M1 L LN- L Part Number Size L M1 N Approx.WL(Lbs.) 4278-007 314 2-1/32 1-3/8 15132 .14 4278-010 1 2-9132 1-23132 13132 .22 Not intended to convey or dispense water for human consumption through drinking or cooking SPIGOT FEMALE ADAPTER Special Reinforced Plastic Thread Style Spigotx SR Fipt PIPE Mt O1.D L LIN Part Number Size L M1 N Approx.Wt.(Lbs.) 4278-007SR 314 1-15116 1-318 11132 .08 4278-010SR 1 2-1/4 1-23132 13132 .13 15 SPEARS MANUFACTURING COMPANY FlameGuard TM CPVC FIRE SPRINKLER PIPING PRODUCTS Lrj- FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style Socket x SR Apt M ------ — M1 L J N Fes—Li Part Number Size L M M1 N Approx.Wt.(Lbs) 4235.101SR 314x1/2 1-29132 1-13132 1-3116 118 .08 4235-130SR 1x1/2 1-31/32 1-23/32 1-3/8 3132 .16 4235-131SR 104 2-3/32 1-314 1-3/8 114 .13 FEMALE SPRINKLER HEAD ADAPTER Special Reinforced Plastic Thread Style with Socket Wrench Flats Socket x SR Fipt M ----------------- M1 M=Flat-to-Flat Dimension 1-1 L +I Part Number Size L M Ml N Approx.Wt.(Lbs.) W4235-101SR 3141/2 2-9/32 1-13132 1-3/16 17/32 .09 W4235-130SR 1x112 2-9132 1-314 1-3116 13!32 .12 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve I=or deviation from the requirements of MADE IN THE U.S.A. a licaoleStateLaws. 14 DS ( FlameGuard" CPVC FIRE SPRINKLER PIPING PRODUCTS FEMALE ADAPTER Brass Thread Insert Style Socket Fipt M — M1 L L I N �L Part Number Size L M M1 N Approx.Wt.(Lbs.) 4235-007 314 2 1-13132 1-3f8 5116 .23 4235-010 1 2-7132 1-3/4 1-11116 13132 .25 4235-012 1-1/4 2-3/8 2-3/32 2-1/16 13/32 .35 4235-015 1-1/2 2-9/16 2-318 2-7/16 7116 .47 4235-020 2 2-25132 2-27132 3-3/16 7116 1.05 Not intended to convey or dispense water for human consumption through drinking or cooking FEMALE ADAPTER Special Reinforced Plastic Thread Style Socket SR Fipt � 1 M M1 LL 1j, Part Number Size L M M1 N Approx.WL(Lbs.) 4235-007SR 3/4 1-718 1-13132 1-318 3132 .08 4235-010SR 1 2-5132 1-23132 1-718 3132 .22 4235-012SR 1-1/4 2-5116 2-118 2-1/16 3116 .20 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of a linable State Laws. 13 SPEARS-MANUFACTURING COMPANY FlameGuard" CPVC FIRE SPRINKLER PIPING PRODUCTS Mj REDUCER COUPLING Socket x Socket M -—-— -- MI Fes--- L Part Number Size L M M1 N Approx.Wt.(Lbs.) 4229-131 1x314 2-3/8 1-23!32 1-13132 7132 .10 4229.167 1-1/4314 2-19132 2-3/32 1-5/8 11132 .17 4229-168 1-1141 2-11/16 2-3/32 1-23132 5116 .18 4229-210 1-1/2014 2-13116 2-11132 1-13132 15132 .19 4229-211 1-U2x1 2-7/8 2-11/32 1-15/16 3/8 .24 4229-212 1-112x144 2-25132 2-3/8 2-3/32 5132 .22 4229-248 2x314 3-3116 2-7/8 1-7116 23132 .32 4229-249 2x1 3-1/8 2-7/8 1-23132 1/2 .31 4229-250 2x1-114 3-3116 2-7/8 2-118 17132 .33 4229-251 2x1-112 3-3/16 2-27132 2-11132 9/32 .31 4229-291 2-1/2x1-112 3-23/32 3-15/32 2-11132 21132 .51 4229.292 2-1/2x2 3-21/32 3-1/2 2-718 13/32 .52 GROOVED COUPLING ADAPTER Groove x Socket PIPE ___ —_ Mt O.D. L —►I Part Number Size L M1 N Approx.Wt.(Lbs.) 4233-012 1-1/4 3-5/8 2-3132 2-11132 .72 4233-015 1-1/2 3-314 2-11132 2-11132 .83 4233-020 2 3-27132 2-27/32 2-11/32 1.27 4233-025 2-112 4.3116 3-15/32 2-7116 2.02 F 4233 032 3 3-9116 4-5132 1-23132 .72 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is cenihed as being in conformance MADE IN THE U.S.A. with State Building Codes 12 Date Jul 31,2015 Approval of this d—a,ont does not authahe a approve any omission or deviation lrom the requirements of applicable state Laws. FtameGuard" CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING CROSS Socket x Socket x Socket x Socket �–►f–M1 ' H1 M ---i— L1 G1 G H L Part Number Size G G1 H H1 L L1 M M1 Approx.Wt.(Lb,.) 4220-131 10/4 718 5/8 2 1-5/8 4 3-114 1-27/32 1-1/2 .35 4220-167 1.1140/4 1-1116 23132 2-1116 1-31/32 4-3132 3-31132 2-1/16 1-13/32 35 4220-289 2-112x1 29132 1-3/4 2-11/16 2-718 5.11/32 5-3/4 3-1/2 1-314 1 .98 COUPLING Socket x Socket -- — -- M H- L sl Part Number Size L M N Approx.Wt.(Lbs.) 4229007 314 2-1/8 1-5/16 3116 .05 4229010 1 2-3116 1-5/8 3132 .08 4229012 1-1/4 2-19/32 2 3/32 .13 4229015 1-1/2 2-718 2-11/32 3132 .22 4229-020 2 3-1/8 2-718 118 .33 4229025 2.1/2 3-11/16 3-15132 3116 .48 4229030 3 4 4-3116 1/4 .89 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve 11 any omission or deviation from the requirements or SP EARS&MANUFACTURING COMPANY applicable State Laws. FlameGuard T" CPVC FIRE SPRINKLER PIPING PRODUCTS j El 450 STREET ELBOW Spigot x Socket J� H1 A M1 HJ I+ ►I PIPE O.D. Part Number Size H H1 ) J1 M7 Approx.Wt(Lbs.) 4227-010 1 1-112 1-5/16 l 2 1/4 1-5/8 .10 4227-012 1-1/4 1-25/32 1-9116 9116 11132 1-31/32 .15 4227-015 1-V2 2-1132 2-1/8 19132 25/32 2-11/32 .29 4227-020 2 1 2-5116 1-15116 25/32 13/32 1 2-718 .44 CROSS Socket x Socket x Socket x Socket r G1 T � M - L1 G H L Part Number Size G G1 H H1 L L1 M Approx.Wt(Lbs.) 4220-007 314 5/8 518 1-21132 1-21/32 3-5116 3-5116 1-13132 .22 4220.010 1 3/4 314 1-5/8 1-5/8 3-1/4 3-1/4 1-23132 .20 4220-012 1-1/4 1-1/8 1-1/8 2-3/8 2-318 4-3/4 4-3/4 2-3132 .63 4220-015 1-1/2 1-7132 1-7132 2-5/8 2-5/8 5-1/4 5-1/4 2-11132 .80 4220-020 2 1-1/2 1-1/2 3 3 6 6 3 1.43 4220-025 2-1/2 1-11116 1-11116 3-7/16 3-7/16 6-718 6-718 3-17/32 2.16 4220.030 3 2-3132 2-3132 3-31/32 3-31/32 7-15116 7-15/16 4-7/16 3.37 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize a approve MADE IN THE USA any omission or deviation from the requirements of a licable Stale Laws. 10 (�Flame,Guard` CPVC FIRE SPRINKLER PIPING PRODUCTS 22-1120 STREET ELBOW Spigot x Socket M1 H1 A H PIPE O.D. Part Number Size H H1 J Ji M1 Approx.Wt.(Lbs.) 4242-007 314 1-1/4 1-112 1/4 1/2 1-3/8 .08 4242-010 1 1-7/16 1-11/32 5/16 7132 1-23132 .14 4242-012 1-1/4 1-9/16 1-25/32 17132 11/16 2-1/16 .21 4242-015 1-1/2 1-13!32 1-23132 1/2 11132 2-11/32 .28 4242-020 2 1-29132 2-1/8 7132 5B 2-7/8 .42 4242-025 2-1/2 2-1/8 2-1/4 13/32 1/2 3-1/2 .68 4242.030 3 2-13132 2-13/32 9/16 17/32 4-5/32 .99 45° ELBOW Socket x Socket r H �—M ►� Part Number Size H J M Approx.Wt.(Lbs.) 4217-007 314 1-5/16 5116 1-5/16 .10 4217-010 1 1-15f32 11132 1-5/8 .11 4217-012 1-1/4 1-5/8 318 2-5132 .21 4217-015 1-1/2 1-27/32 15!32 2-11/32 .32 4217-020 2 2-1/8 21/32 2-7f8 .48 4217-025 2-112 2-13132 21/32 3-1/2 .79 4217-030 3 2-314 718 4-5132 1.22 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Eckhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conlormance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or a rove 9 any omission or deviation from the requirements of SPEARS MANUFACTURING COMPANY applicable State Laws. FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS 900 STREET ELBOW Spigot Socket H1- 1G, G - M1 H PIPE O.D. Part Number Size G G1 H H1 M1 Approx.Wt(Lbs.) 4209-007 3/4 15116 17/32 1.15/16 1-17/32 1-318 .12 4209-010 1 1-9/32 23132 2.13132 1-27132 1-3/4 .21 4209-012 1-1/4 1-9116 27132 2-13/16 2-3/32 2-3/32 .32 4209-015 1-i/2 1-15/32 1-3116 2-27/32 2-9/16 2-11/32 .42 4209-020 2 1-23132 1-318 3-7/32 2-15116 2-27132 .65 22-1/20 ELBOW Socket x Socket fJ I H i M > Part Number Size H J M Approx.Wt(Lbs.) 4216-007 314 1-3116 7/32 1-13132 .09 4216-010 1 1-318 9132 1-25132 .14 4216-012 1-114 1-112 5116 2-3132 .20 4216-015 1-112 1 1-7/16 13132 1-318 .19 4216-020 2 1-7/8 318 2-27132 .43 4216-030 3 2-318 1/2 4-5/32 1.00 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 States) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve MADE IN THE U.S.A. any omission or deviation from the requirements of applicable state Laws. 8 DS ( FiameGuard TM CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD 900 ELBOW Brass Thread Insert Style Socket x Fipt H1 G1 G -- M1 1 H j M �I Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4207-101 3/4x1/2 7116 1-5132 1-23/32 1-17132 1-13/32 1-17!32 .25 4207-130 1x112 15/32 1-518 1-9116 1-11/16 1-23132 1-17132 .28 4207-131 1x314 17132 1-1/4 1-21132 2 1-23132 1-3/8 .25 4207-166 1-1/4x1/2 15132 1-17/32 1-11/16 1-15116 2-3132 1-17132 .33 Not intended to convey or dispense water for human consumption through drinking or cooking SPRINKLER HEAD 900 ELBOW Special Reinforced Plastic Thread Style Socket SR Fipt H1---ry pil G M1 H Ll M Part Number Size G G1 H H1 M M1 Approx.Wt.(Lbs.) 4207-IOISR 3/4112 11132 13116 1-15132 1-1/2 1-13/32 1-3116 .14 4207-130SR 1x112 7/16 7/8 1-9/16 1-5/8 1-23132 1-3/8 .20 4207-131SR 104 112 718 1-518 1-9116 1-23/32 1-3/8 .16 4207-166SR 1-1/41/2 13132 1 1-1/32 1-21132 1-23/32 2-3132 1-7/32 .19 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. 7 SPEARS@ MANUFACTURING COMPANY FlameGuard TM CPVC FIRE SPRINKLER PIPING PRODUCTS 900 ELBOW Socket x Socket G H I�M Part Number Size G H M Approx.Wt.(Lbs) 4206-D07 34 9/18 1-112 1-5/16 .07 4206-010 1 314 1-5/8 1-518 .11 4206-012 1-1/4 7/8 2-5132 2 .21 4206-015 1 1-1/2 1-5/32 2-17/32 2-3/8 .41 4206-020 2 1-13132 2-29/32 2-7/8 .45 4206-025 2-112 1-518 3-7116 3-7/16 1.17 4206-030 3 1-29132 3-23(32 4-3/16 1.80 SIDE OUTLET ELBOW Socket x Socket x Socket — M G H Part Number Size G H M Approx.Wt.(Lbs.) 4213-007 314 27/32 1-19/32 1-5116 .09 4213-010 1 13/16 1-7/8 1-5/8 .18 REDUCING 900 ELBOW T.R ARNOLD&ASSOCIATES,IN,-. P.O.sox 1081 Socket x Socket Elkhart,IN 46514 H1—+j Massachusetts G1 A State(s)Accredited Evaluation and G Inspection Agency 1 This document is certified as being in conformanc I— with State Building Codes. H Date Jul 31,2015 t Approval of this document does not authorize or appro e IIL any omission or devialion from the requirements of I I a licable State Laws. N—M—*f Part Number Size G G1 H H1 M M1 Approx.WL(Lbs.) 4206-131 1x3/4 25132 11/16 1-25!32 1-25132 1-19!32 1-5116 it MADE IN THE U.S.A. 6 FlameGuard'" CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket SR Fipt x Socket M1 �►{ 11 G1 j— H1 M t M2 L G H L H2 2 Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lb,.) 4203-122SR 1x1/Dc1 27/32 314 1-3132 1-23132 1-510 1-13116 3-7116 1-23132 1-23/32 1-7132 .21 STREET TEE Spigot x Socket x Socket a'2 R H1 G1 H -III- Q L Part Number Size G G1 G2 H H1 H2 L M1 M2 Approx.Wt.(Lbs.) 4244007 314 13116 27/32 27!32 1-13116 1-7/8 1-7/8 3518 1-13132 1-13132 .16 4244010 1 1-5/32 1-1132 1-132 2-18 1-29132 1-29/32 4.3116 1-3/4 1-314 .27 4244012 1-114 1-1/4 1 1 2-7/16 2-9/32 2-9132 427/32 2-3132 2-3132 .42 4244015 1-112 1-13116 1-1/8 1-1/8 2-7/8 2-9116 2-9116 5-11132 2-11132 2-11132 .56 4244020 2 1-23/32 1-7116 1-13132 3.1/4 1 2-15116 2-15116 6-5/32 2.718 2-7/8 .84 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. 5 SP EARSO MANUFACTURING COMPANY FlameGuard" CPVC FIRE SPRINKLER PIPING PRODUCTS SPRINKLER HEAD TEE Special Reinforced Plastic Thread Style Socket x Socket x SR Fipt Mi M - -- h G1 T H1 � G Ilt.�--H— H2 L Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.WL(Lbs.) 4202-101SR 3/4x3141/2 5/8 25132 518 1-5/8 1-15/32 1-5/8 3-7/32 1-13132 1-3116 1-13132 .16 4202-124SR 1x314A/2 7/16 29/32 9116 1-19/32 1-5/8 1-9/16 35132 1-23132 1-3116 1-17/32 .19 4202-130SR 1x1x1/2 7/16 29/32 7/16 1-9/16 1-5/8 1-9/16 31/8 1-23!32 1-3116 1-23132 .20 4202-010SR 1x1x1 21/32 3/4 21/32 1-25/32 1-5/6 1-25132 319/32 1-23132 1-11!16 1-23132 .26 4202-156SR 1-114x112 15/32 1-5/32 19132 1-23132 1-718 1-23132 313132 2-3132 1-3/16 1-23132 .26 4202-166SR 1-1/41-1/4x1/2 7116 1-1/8 7116 1-11116 1-27132 1-11116 33/8 2-3132 1-3/16 2-3132 .26 4202-168SR 1-1/41-1/41 27/32 1-1132 27/32 2-3132 1-29/32 2-3132 47/32 2-3132 1-11/16 2-3/32 .34 4202-199SR 1-112x1-1140/2 9116 1-9132 17132 1-15/16 2 1-25132 323132 2-11132 1-3116 2-3132 .33 4202-209SR 1-1/2x1-1/2x112 1/2 1-1/4 1/2 1-7/8 1-31/32 1-7/8 33/4 2-11/32 1-3/16 2-11/32 .35 4202-211SR 1-112x1-1/2x1 27/32 1-7132 27/32 2-7/32 2-1/8 2-7132 415132 2-11/32 1-23/32 2-11/32 .44 4202-237SR 2x1-1/2x1/2 23132 1-9116 318 2-7132 2-9132 1-3/4 331/32 2 718 1-3/16 2-11/32 .45 4202-247SR 2x2x1/2 1/2 31/32 1/2 2 1-11/16 19/32 4 2-718 1-3/i6 2-7/8 48 4202-287SR 2-1/2x2-1/2x1!2 17/32 1-3/4 17/32 2-9132 2-1/2 2-9132 419132 31/2 1-7132 31/2 .78 SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Fipt x Socket G1 I � Ht M —- -I M2 I G 4 G2 11�-H— H2 I. Part Number Size G G1 G2 H Hl H2 L M M1 M2 Approx.Wt.(Lbs.) 4203122 txtt2xl 23132 314 1-1/4 1-518 1-5/8 1-15116 31/2 1-23132 1-23132 1-3116 .25 Not intended to convey or dispense water for human consumption through drinking or cooking T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. MADE IN THE U.S.A. Date Jul 31,2015 4 Approval of this document does not authorize or approve any omission or deviation from the requirements of applicable State Laws. .................. FlameGvard" CPVC FIRE SPRINKLER PIPING PRODUCTS REDUCING TEE T.R ARNOLD&ASSOCIATES,INC. (continued) P.O.Box 1081 Socket x Socket x Socket EBchari,IN 46514 M1 State(s) Massachusetts - ' Accredited Evaluation and HI Inspection Agency is documern.s cerohed as befrg.n conrormarice M - M2 w to state B ld;oy codes. G 1 Date Jul 31,2015 Approval of[his document does-authorize or approv G G2 aey om ssm or de—hm nom the tequtr meets or e 11 H2 r aae state Las. L- Part Number Size G G1 G2 H Hl H2 L M M1 M2 Approx.Wt. (Lbs.) 4201-248 2x2x3/4 11116 1.13132 11116 2-7/32 2-7116 2-7/32 4-7116 2-27132 1-318 2-27132 .52 4201-249 2x2xl 27132 1-7116 27132 2-11132 2-9/16 2-11132 4-23132 2-7/8 1-314 2-7/8 .57 4201-250 2x2xl-114 1 1-11132 1 2-17/32 1 2-19/32 2-17132 5-3/32 2-27132 2-3/32 2-27132 .63 4201-251 WA-1/2 1-7/32 1-13/32 1-7/32 2-11115 2-25/32 2-11116 5-318 2-27132 2-11132 2-27132 .85 4201-269 2-1/&2-112x1 29132 25132 29132 2-21132 1-29132 2-21/32 5-5/16 3-112 1-23/32 3-1/2 1.03 4201-290 2-1/2x2-112x1-1/4 1-3132 1-23132 j 1-3132 2-27132 2-31132 2-27132 5.21/32 3-17/32 2-3132 3-17132 1.13 4201-291 2-1/2x2-11W-1/2 1-3116 1/2 1-3116 2-15/16 1-7/8 2-15116 5.7/8 3-15132 2-11132 3-15132 1.26 4201-292` 2-1/82.11D2 1-19/32 2-118 1-19/32 3-11132 3-5/8 3-11/32 6-11116 3-17132 3-17/32 3.17132 2.46 4201-335 3x3x1 718 1-15116 7/8 2-3/4 31/16 2-3/4 5-15132 4-3116 1-23/32 4-3/16 1.26 4201-336' 3x30-114 1-3/8 1-314 1-318 3-5/16 3.112 3-5116 6-518 4-1/8 2-7/8 4-1/8 1.94 4201-337" 300-1/2 1-3/8 2 1-3/8 3-5/16 3-5/8 3-5116 6-518 4-118 2 4-1/8 1.85 4201-338 3.3x2 1-7116 1-13116 1-7116 3-5/16 35116 3-5116 6-518 4-5132 2-718 4-5/32 1.68 4201-339 1 323x2-1/2 1 1-3/4 1-31132 1-314 3-5/8 3-23132 3518 7-1/4 4-5132 3-7116 4-5132 2.08 Branch Outlet Sized with Bushing SPRINKLER HEAD TEE Brass Thread Insert Style Socket x Socket x Fipt F G1 1 G-4--f---4-—G2 +—H—► H2 L— Part Number Size G G1 G2 H H1 H2 L M M1 M2 Approx.Wt.(Lbs.) 4202-101 3143141/2 7116 1-5132 7116 1-7116 1-17/32 1-7/16 2-29/32 1-3/8 1-7/32 1-3/8 .27 4202-124 1AAA/2 7116 1-11132 9116 1-9/16 1-11/16 1-9/16 3-1/8 1-11/16 1-318 1-3/8 .26 4202-130 lxlxl/2 7116 1-5116 7116 1-9/16 1-11116 1-9/16 31/8 1-23/32 1-17/32 1-23132 .32 4202-010 1x1x1 11116 1-3/32 11/16 1-13/16 1-29132 1-13!16 319132 1-23132 1-23/32 1-23/32 .37 4202-156 1-1/4x1x1/2 7116 1-15/32 9116 1-11/16 2-1132 1-11/16 3-3/8 2-3132 1-7/32 1-314 .30 4202-166 1-1/41-1/40/2 7116 1-9116 7116 1-11/16 1-15116 1-11116 33/8 2-1116 1-17132 2-1116 .37 4202-199 i-1/2x1-1141/2 112 1-5/8 9116 1-718 2-3116 1-13116 3-11116 2-5116 1-7/32 2-1/16 .37 4202-209 1-112x1.112x1/2 112 1-2362 112 1-7/8 2-3132 1-718 3314 2-5/16 1-17132 2-5116 .45 4202-237 2x1-112x1/2 1/2 1-7/8 17/32 2 2-7/16 1-29132 315116 2-27132 1-7132 2-5/16 .48 4202-247 WA12 112 I 1-31132 1/2 2 2-3/8 2 4-1132 2-27132 1-17132 2-27132 .58 Not intended to convey or dispense water for human consumption through drinking or cooking 3 SPEARSO MANUFACTURING COMPANY FlameGuardT" CPVC FIRE SPRINKLER PIPING PRODUCTS ) E.J] TEE T.R ARNOLD&ASSOCIATES,INC. Socket x Socket x Socket P.O.Box Elkhart,IN 465 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This d«ument is—red as Deng in eonrormm,ee with Slate 9u11ding Codes. Date Jul 31,2015 Approv of Nis document does no[authorize or approv any amiss n a deviation Irom[he requir erns of e H ficahie sate yaws. L Part Number Size G H L M Approx.Wt(Lbs) 4201-007 314 9/16 1-1/2 2-31132 1-5116 .11 4201-010 1 29132 1-13116 3-5/8 1-5/8 .19 4201-012 1-1/4 15132 2-3132 4-7!32 2 .29 4201-015 1-1/2 1-5132 2-9115 5-3132 2-11/32 .54 4201-020 2 1-13132 2-15/16 5-718 2-71B .86 4201-025 2-112 1-23132 3-112 7 3-15132 1.62 4201-030 3 2-1/16 3-15/16 7-718 4-3/16 3.02 REDUCING TEE Socket x Socket x Socket M1 j Hi M G1 G G2 H —N2 L Part Number Size G 131 G2 H H1 H2 L M M1 M2 Approx.Wt. (Lbs.) 4201-102 314x3/4xl 3/4 25132 314 1-11116 1-13/16 1-11116 3-318 1-5116 1-21132 1-5/16 .13 4201-125 1x3/4314 21/32 13116 518 1-25/32'. 1-13116 1-5/8 3-13132 1-17/32 1-5116 1-5116 .15 4201-126 1x3140 314 1-718 1-3132 1 1-27/32' 1 2-31132 1-31132 3-13116 1-23132 1-23/32 1-13132 .26 4201-131 10414 21/32 13/16 21132 1-25132 1-13/16 1-25/32 3.9/16 1-5/8 1-5/16 1-5/8 .16 4201-157 1-1/4xix314 11/16 1-1132 11/16 1-15116 2-1132 1-13/16 3-25132 2-3/32 1-13/32 1-23/32 .32 4201-158 1-1/421x1 27132 29/32 25132 2-1/16 2-1132 1-29132 3.15/16 1-31132 1-5/8 1-5/8 .24 4201-159 1-1/4x1x1-114 31132 31132 31132 2-7/32 2-7/32 2-3132 4-11/32 2-3/32 2-3132 1-23132 .35 4201-167 1-11421-1/4x314 21/32 1 21132 1-29/32 2 1-29132 3-13116 2 1-5/16 2 .22 4201-168 1-114x1-1/4x1 13116 1 13116 2-1/16 2-1/8 2-1116 4-118 1-31132 1-5/8 1-31/32 .24 4201-169 1-1/4x1-114x1-1/2 1-1/8 15116 1-1/8 2-3/8 2-11132 2-318 4314 2-3132 2-11132 2-3132 .51 4201-201 1-112x1-114x3/4 11/16 1 1/4 2-1/16 2 1-15116 4 2-5/16 1-318 2-1/16 .41 4201-202 1-1/2x1-1/4x1 27132 1-1/32 1 2-7132 2-5132 2-114 4-15132 2-5/16 1-11116 2-1116 .42 4201-210 1-112x1-1/20/4 23132 1-1116 23132 2-3/32 2-1/32 2-3132 4-3116 2-5116 1-318 2-5/16 .37 4201-211 1-1/20-1120 13116 1-3116 13/16 2-3116 2-1/4 2-3/16 4-3/8 2-11132 1-23/32 2-11132 .41 4201-212 1-1!2x1-112x1-114 1 1-118 1 2-38 2-11132 2-3/8 4-13116 2-11132 2-3/32 2-11132 .48 4201-213 1-112x1-112x2 1 1-5116 1-118 1-5116 2-11116 2-21132 2-11116 5-318 2-11132 2-27/32 2-11132 .72 MADE IN THE U.S.A 2 T.R ARNOLD&ASSOCIATES,INC. P.O.B..1081 ElkkaA,IN 46514 States) Massxhusetts AccreOiletl Evaluation aM Inspection Agency m as tengn momma See Ju131,2015 wffln Er,.] ( FlameGuardr'" CPVC FIRE SPRINKLER PIPING PRODUCTS '7 The information contained in this publication is based on current information and Product design at the time of publication and is subject to change without notification.Our ongoing commitment to product improvement may result in some variation.No representations,guarantees or warranties of any kind are made as to its accuracy,suitability for particular applications or results to be obtained therefrom.For verification of technical data or additional information not contained herein,please contact Spears''Technical Services Department(West Coast:(818)364-1611—East Coast:(717)938-9006). General Information RECOMMENDATIONS FOR INSTALLERS AND USERS: Plastic piping systems should be ENGINEERED,INSTALLED and OPERATED in accordance with ESTABLISHED DESIGN AND ENGINEERING STANDARDS AND PROCEDURES for plastic piping systems. Suitability for the intended service application should be determined by the installer and/or user prior to installation of a plastic piping system.All Installation and maintenance personnel should be trained in the proper handling and installation requirements and precautions of plastic piping systems.PRIOR TO ASSEMBLY,all piping system components should be inspected for damage or irregularities.Mating components should be checked to assure that tolerances and engagements are compatible.Do not use any components that appear irregular or do not fit properly.Contact the appropriate manufacturer of the component product in question to determine usability.Consult all applicable codes and regulations for compliance prior to installation. Installation must be made in accordance with Spears'Manufacturing Company FlameGuardTM CPVC Fire Sprinter Piping Products Installation Instructions-FG-3 NOTE—Individual or group instruction in correct solvent welding procedures is available by contacting your local distributor or your servicing Spears"Regional Distribution Center. SOLVENT CEMENT CONNECTIONS—Spears'Manufacturing Company recommends the use of Spear?Two Step FS-1 primer with FS-3 solvent cement OR Spear?FS-5 One Step solvent cement for joining Spears'products.Use of solvent cementing products not approved for CPVC fire sprinkler systems,or failure to follow installation instructions will automatically void the warranty. THREADED CONNECTION—Spears Manufacturing Company recommends the use of Spear?BLUE 75T11 Thread Sealant.This product has been tested by Spears°and the sealant manufacturer for compatibility with the Spears'CPVC fire sprinkler products.Consult the sprinkler head manufacturer before using this product.WARNING:OTHER PIPE JOINT COMPOUNDS OR PASTES MAY CONTAIN SUBSTANCES THAT COULD CAUSE STRESS CRACKING IN THE CPVC OR OTHER FITTING COMPONENTS.Care must be taken to avoid over torquing-generally 1 to 2 turns beyond finger fight is all that is required to make up a threaded connection.Factory testing has indicated 10-25 ft.lbs.of torque is adequate to obtain a leak free seal. GASKET SEALED THREAD CONNECTIONS—This type of connection can only be made with Spears'TorqueSafelR style Gasket Sealed Female Sprinkler Adapters. DO NOT USE ANY TYPE OF THREAD SEALANT WHEN INSTALLING THIS TYPE OF ADAPTER.Tape or paste may impair proper sealing and function.Testing has shown that hand tight until snug is all that is needed to seal this special connection. NOT FOR USE WITH COMPRESSED AIR OR GASES WARNING: DO NOT USE COMPRESSED AIR OR GAS TO TEST ANY PVC OR CPVC THERMOPLASTIC PIPING PRODUCT OR SYSTEM,AND DO NOT USE DEVICES PROPELLED BY COMPRESSED AIR OR GAS TO CLEAR SYSTEMS.THESE PRACTICES MAY RESULT IN EXPLOSIVE FRAGMENTATION OF SYSTEM PIPING AND COMPONENTS CAUSING SERIOUS OR FATAL BODILY INJURY. Dimension Reference G = (LAYING LENGTH)Intersection of center lines to bottom of socket/thread,90'elbows, M = Outside diameter of secket/thread hub;t 1/16 inch. tees,crosses;±1132 inch. N = Socket bottom to socket bottom;couplings;t 1116 inch. H = Intersection of center lines to face of fitting;90°elbows tees,crosses;±1/32 inch. Q = Width of flats;±1/16 inch. J = Intersection of center lines to bottom of sockeUfhread;45°elbows;±1132 inch W= Height of cap;±1/16 inch. L = Overall length of fittings;±1/16 inch. CPVC FIRE SPRINKLER PIPE SDR 13.5(ASTM F 442) Nominal Size Average O.D. Average I.D.Part Number Approx.Weight Lbs.lFt. Inches (mm} Inches (mm) Inches (mm) CP-007 314 (19.1) 1.050 (26.7) .874 (22.5) .181 CP-010 1 (25.4) 1.315 (33.4) 1.101 (28.2) .280 CP-012 1-1/4 (31.8) 1.660 (42.2) 1394 (35.6) .418 CP-015 1-1/2 (38.1) 1.900 (48.3) 1.598 (40.7) .550 CP-020 2 (50.8) 2.375 (60.3) 2.003 (50.9) .872 CP-025 2-1/2 (63.5) 2.875 (73.0) 2.423 (61.5) 1.260 CP-030 3 (76.2) 3.500 (88.9) 2.950 (75.0) 1.900 SPEARSc*MANUFACTURING COMPANY FlameGuar&m SPEARS CPVC F/RE SPR/NKLER PIPING PRODUCT' �I T'4 G TECHNICAL INFORMATION WEIGHTS & DIMENSIONS ,r T.R ARNOLD&ASSOCIATES,INC. Febfuat/ 1, 2010 P.O.Box 1081 SUPERSEDES ALL PREVIOUS EDITIONS Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. ///►' `1` Date Jul not 2015 f/may 4 Approval of this document does not authorize or approve If any omission or deviation from the requirements of 0 /.pi applicable Stale Laws. (A►(ii/�/ 1'969 °d CRA=G r � � x � UKAS 6aia" O.-/try.�r-��t.r/tlla.M M-. �......,...., ..._T11-, C. FG-4-0210 w.■.•..r . ISO 9961. sons RBM-Guardian Fire Protection Inc. 8 Enterprise Drive Albany, New York 12204 Material Submittal for: Housing For Veterans 421 North Main Street Leeds, Mass 01053 T.R ARNOLD&ASSOCIATES,INC. P.O.Box 1081 Elkhart,IN 46514 State(s) Massachusetts Accredited Evaluation and Inspection Agency This document is certified as being in conformance with State Building Codes. Date Jul 31,2015 Approval of this document does not authorize or approve any omission or deviation from the requirements of apfifc,,lble State Laws. Contract With: BBI Construction Services, LLC 302 Washington Avenue Ext. Albany, New York 12212 /- �o Commonwealth of Massachusetts Manufactured Buildings Program Transmittal Form for all correspondences relating to Manufactured Buildin sand Building onents To: Linda Shea,Manufactured Buildings Program Phone Number: Date Transmitted Linda.shea@state.ma.us 508-422-1955 Commonwealth of Massachusetts 50 Maple Street Board of Building Regulations and Standards Suite One Milford Massachusetts 01757-3698 The person forwarding material shall complete the following portion of this transmittal. Please print clearly or type required information. Name of Person Daren Lehman MC Number TPIA Number Transmitting Material I 1 200 03 The following information is being transmitted to the Board of Building Regulations Please indicate the Distinct Use And Standards and\or the Department of Public Safety for reasons detailed below Model and\or Serial Group (Please check the appropriate box or give a further description of the transmitted Number pertaining to Items under the section labeled other. Be sure to identify the appropriate Use Grou transmitted items. Building plans for review and approval Building plans forwarded as a record copy for your files(review not required). Revised building plans for review. (Please clearly identify revisions on the X Soldier On R-2 Tans. Revised building plans forwarded as a record copy for your files review not required-Please clearly identify revisions on the Tans. When submitting materials identified below,please ensure that you clearly indicate modifications to each page(s). Also,please indicate the BBRS\DPS Identification Number on all applicable materials. Modifications to programs manuals or drawings shall be accompanied by an index which clearly identifies which pages are to be removed and which pages are to be re laced. (Check the appr o riate box for materials transmitted. Compliance Assurance Programs Original submission Modification to: Calculations Manual Original submission Modification to: Installation Manual Original submission Modification to: Systems Drawings Original submission Modification to: X Other-Provide a detailed description of any other materials which are being transmitted. Identify any revisions clearly along with BBRS No. Also,identify the requested action. Site Location:421 N:Main Street,Leeds,MA 01053 The office transmitting this information has reviewed the above mentioned and attached materials and has found them, to the best of our knowledge and abilities,to be in compliance with the codes and\or rules and regulations for the Commonwealth of Massachusetts'Manufactured Building Program,as applicable. Signed by: Date:July 31,2015 S\mfg\forms\mfgtransmittal-Revised April,2015