Loading...
38A-139 (2) Load Short Form Job: Date: 7RWE- SECOND FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma 'Project • • For: Unit A 7, Pecoy Companies Moser Street"East, Northampton, MA Htg Clg Infiltration Outside db(°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 29 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (fr) (Btuh) (Btuh) (cfm) (cfm) BATH/HALL 168 3194 1241 69 56 BED 1 320 5633 2457 121 112 BED 2 168 3988 1996 86 91 SECOND FLOOR 656 12815 5694 276 259 Other equip loads 0 0 Equip. @ 0.92 RSM 5239 Latent cooling 128 TOTALS 1 656 1 12815 1 5367 1 276 1 259 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Jun-1016:04:18 - wri htsOf Right-Suite®Universal 2015 15.0.05 RSU17313 Page e 3 ...OADS\RICHIE'S PECOY 2 bed Moser st UNIT A7.rup Calc=MJ8 Front Door faces: N Load Short Form Job: Date: 4) /,E` SECOND FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma • iiict • • For: Unit A 7, Pecoy Companies Moser Street"East, Northampton, MA I! - • • o Htg Clg Infiltration Outside db(°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD(°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference (gr/lb) 29 24 OMWARWA HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) BATH/HALL 168 3194 1241 69 56 BED 1 320 5633 2457 121 112 BED 2 168 3988 1996 86 91 SECOND FLOOR 656 12815 5694 276 259 Other equip loads 0 0 Equip. @ 0.92 RSM 5239 Latent cooling 128 TOTALS 1 656 l 12815 I 5367 I 276 1 259 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + 2015wri htsaft -Jun-1016:04:18 Right-Suite®Universa12015 15.0.05 RSU17313 Page 3 ...OADS\RICHIE'S PECOY 2 bed Moser st UNIT A7.rup Calc=MJ8 Front Doorfaces: N Load Short Form Job: ek Date: /E' FIRST FLOOR By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project t t For: Unit A 7, Pecoy Companies Moser Street"East, Northampton, MA ® ° w • w Htg Cig Infiltration Outside db(°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 29 24 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (8Z) (Btuh) (Btuh) (cfm) (cfm) HALF BATH 70 2587 1132 56 51 KITCHEN FAMILY 560 9762 5803 211 264 DINING 160 3195 1439 69 65 FIRST FLOOR 790 15544 8374 335 381 Other equip loads 0 0 Equip. @ 0.92 RSM 7704 Latent cooling 123 TOTALS I 790 I 15544 l 7827 l 335 l 381 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri I1SOft 2015-Jun-1016:04:18 - Right-Suite®Universal 2015 15.0.05 RSU 17313 Page t - ...OADS\RICHIE'S PECOY 2 bed Moser st UNIT A7.rup Calc=MJ8 Front Door faces: N Load Short Form Job: Date: 0 7R&W' Entire House By: RICHIE RICHIE'S AIR CONDITIONING & HEATING 81 Industrial Lane,Agawam,Ma Project • • For: A 7, Pecoy Companies er Street"East, Northampton, MA D- Htg Clg Infiltration Outside db(°F) 0 87 Method Simplified Inside db(°F) 70 75 Construction quality Tight Design TD (°F) 70 12 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 29 24 mosemmm HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 612 cfm Actual air flow 612 cfm Air flow factor 0.022 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.98 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft) (Btuh) (Btuh) (cfm) (cfm) FIRST FLOOR 790 15544 8374 335 381 SECOND FLOOR 656 12815 5694 276 259 Entire House 1446 28359 13364 612 612 Other equip loads 0 0 Equip. @ 0.92 RSM 12295 Latent cooling 251 TOTALS 1 1446 1 28359 1 12546 1 612 1 612 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + wri htSUft 2015-Jun-10 16:04:18 Right-Suite®Universal 2015 15.0.05 RSU17313 Page e 1 ...OADSIRICHIE'S PECOY 2 bed Moser st UNIT A7.rup Calc=MJ8 Front Door faces: N INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yes L1 No❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy V Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box ,/1 hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Progress Inspections Date Comments Final Inspection Date Comments Type of License: By t Master Title ❑ M aster-Restricted .1 Citylrown ❑Journeyperson ' Signature of Licensee Permit# ❑Journeyperson-Restricted License Number: M S3 I Fee$ ❑ Check at www.mass.govidpi Inspector Signature of Permit Approval Commonwealth of Massachusetts Sheet Metal Permit Date : Permit # _ w Estimated Job Cost:'K �' Permit Fee: $ Plans Submitted: YES NO Plans Reviewed: YES NO Business License# Applicant License# s31 Business Information: Property Owner/Job Location Information: Name: R1 Name: Pemy M Street: P® L1;3r _ _ w ,N? Street: W-T kri MC�S�R sfi. City/Town: 4k QN.,%)f0, Mfg . City/Town: koM f} Mf r4, MN Telephone: L113 .9%9— 1c L4LA Telephone: L413 r1wg Photo I.D. required/ Copy of Photo I.D. attached: YES NO *� Building Type: Residential: 1-2 family Multi-family Condo/Townhouses Commercial: Office Retail Industrial Educational Institutional Building Cubic Footage: under 35,000 cu. ft. c/ over 35,000 cu. ft. Sheet metal work to be completed: New Work: .,/ Renovation: HVAC Metal Roofing Kitchen Exhaust Systems Chimney/Vents Provide brief description of work to be done: Ff�aQ.\t^Tz- AKO zrr4Z-rRu_ 4utv,_ rtkk FZIQ "1u0c: 5 -�►. ALANO xtATAU.- 0LM,*t ,4_ tee. aMk FReSN Ate. x� A�C�-� � aa� File#SM-2015-0049 APPLICANT/CONTACT PERSON RICHIES AIR CONDITIONING&HEATING INC ADDRESS/PHONE P O BOX 407 (413)789-1244 Q PROPERTY LOCATION 99 MOSER ST-LOT A7 MAP 38A PARCEL 139 ZONE PV THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out ELO 7b t ' Fee Paid Typeof Construction: DUCTWORK SFH New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 531 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commissi Permit DPW Storm Water Management e u in O icial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning&Development for more information. 99 MOSER ST - LOT A7 SM-2015-0049 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIs#: 12110 Map 38A -- Block: 139 SHEETMETAL PERMIT ILot:� PP _ „�... SHEETMETAL Category: SHEETMETAL Permit# SM-20115-00449 PERMISSION IS HEREBY GRANTED TO: Project# JS-2015-001293 Est. Cost: $7,000.00 Contractor: License: Expires: Fee Charged:$25.00 RICHIES AIR CONDITIONING& Sheetmetal-531 03/15/2016 Balance Due:$.00 Owner: KENT PECOY&SONS CONSTRUCTION INC #of Fixtures Applicant: RICHIES AIR CONDITIONING&HEATING INC Digsafe# _ AT: 99 MOSER ST-LOT A7 UseGroup ConstClass -_---- -- -- ISSUED ON: 18-Jun-2015 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: DUCTWORK SFH THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2015-006836 18-Jun-15 17075 $25.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck @northamptonma.gov GeoTMSO 2015 Des Lauriers Municipal Solutions,Inc.