29-404 (2) _ nn�lRdllDla�t E Trinarnount MODULE -P .1 Mono Multi Solutions DIMENSIONS OF PV MODULE ELECTRICAL DATA 4 S"C unst:mm Peak Power Watts-PM..(Wp) 250 255 260 265 - 941 Power Output Tolerance-PNUx(%J 0^+3 o , Maximum Power Current-l-(V) 30.3 30.5 30.6 30.8 uNapN O THE Tnn'a1w%1,-%1ount �x Maximum Power Current-IMPV(A) 8.27 8.37 8.50 8.61 N.waPUTE Open Circuit Voltage Voc(V) 38.0 38.1 38.2 38.3 0 1wsTauwc No�E Short Circuit Current-lsc(A) 8.79 8.88 9.00 9.10 Module Efficiency IF,(%) 15.3 15.6 15.9 16.2 MODULE STC:Irradiance 1000 W/m',Cell Temperature 25°C Air Mass AMI,5 according to EN 60904-3. Typical efficiency reduction of 4,5%at 200 W/m'according to EN 60904-I. � b b g ELECTRICA€.DATA*NOCT Maximum Power Pm.x(wp) 186 190 193 197 Maximum Power Voltage-Vrse(Y) .28.0 28.1 28:3 28.4 MULTICRYSTALCINE MODULE Maximum Power Current-l-P(A) 6.65 6.74 6.84 6.93 - �� �' 6-04.3 GROUNgNG NOLE T 7� l w i.■n. T w PD05.18 A A Open Circuit Voltage(V)-Voc(V) 35.2 35.3.. . 35.4 x 35.5 WITH 1 RINAMOUNt FRAME NwiN wLE Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 _ NOCT:Irradiance at 800 W/m'.Ambient Temperature 20°C.Wind Speed I m/s. 250-265W.. F 812 180 Back View MECHANICAL DATA POWER OUTPUT RANGE Solar cells Multicrystalline 156.156 mm(6 inches) I t Cell orientation 60 cells(6•10) U("fk Fast and simple to install through drop in mounting solution Module dimensions 1650.992 x 40 mm(64.95 x 39.05 x 1.57 inches) V � Weight .19.6 kg(43JZt$sJ 1�s - ---- . Glass 3.2 mm(0.13 inches).High Transmission,AR Coated Tempered Glass MAXIMUM EEFtCIENCY L Backsbeet White A-A Frame Black Anodized Aluminium Alloy Good aesthetics for residential applications 1-Box' IP 65orIF67rated ,�A/ Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 1200 mm(47.2 inches) POSITIVE POWER TOLERANCE I-V CURVES OF PV MODULE(261 Connector HAAmphenof t000 Fire Type UL 1703 Type 2 for Solar City Highly reliable due to stringent quality control xoG 1 �w � I -As a eridirtg ._ .. o L, - TEMPERATURE RATINGS MAXIMUM RATINGS ( P _°i r r?( t r r;.� u Nominal Operating Cell Operational Temperature -40-+85°C in re,c c x 'r r lose . � _ - 1 ) wr��=„n=t(71 U �s. ,i;i5 aoo ;_ __ Temperature(NOCT) 44°C ±2°C Maximum System 1000V DC(lEC) _........ zoo 1 2now1, Temperature Coefficient of Piwuj -0.41 /°C ' Voltage 1000V DC(UQ plesu'l:.;e,1r tin d i' Tr.�T„is '00 -- - -',, -- Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A ,r y a x pi nr: 1 er - yecic it, Certified to withstand challenging environmental o000 o m 40 4o so 7emperatureCoef6cientoflsc 0.05%/°C vonaeeNl cl vr,J t e m-,nt oifr I;o a've. COrtCtltlt3rt5 ci Irii,a is c eng i;bje - WARRANT' CERTIFICATION l0 year Product Workmanship Warranty 25 year linear Power Warranty r t Eli? .. Ttie 7t. SPL= Please refer to product warranty for details a and A.':'er�Ur::,Nr�cis f e c tL r},r; r:E`i LINEAR PERFORMANCE WARRANTY ®' Er PACKAGING CONFIGURATION 10 Year Product Warranty•25 Year Linear Power Warranty coMPU.N, Modules per box:26 pieces w Tidna Solar Limited Modules per 40'container!728 Pieces - d 100% Additional 0 90% alCe/zany rFina$odor iFrleaP warrant CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. @-v o Y ® (°'°{ G 2015 Tr na Solar L mited.All rights reserved.Specifications Included In this datasheet are subject to 'ICS" 80% sl change w,thout not ce.-ar:-T_ne ,}TS•.+c4:'.1ei Years 5 10 15 20 25 THE Temamount MODULE . Mono Multi Solutions DIMENSIONS OF PV MODULE ELECTRICAL DATA:v SIC unit'mrn Peak Power Watts-P-(Wp) 245 250 255 260 941 Power Output 0-+3 1 o uh Maximum Power Voltage Vmr(V) 29.9 30.3 30.5 30 6 wrcrro �o THE Trinaw[ %1^1 o u 1-1 �x Maximum Power Current Imea(AJ 8.20 8.27 8,37 8.50 T o Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 s «r Short Circuit Current 1.(A) 8,75 8.79 8.88 9.00 Module Efficiency qm(%) 15.0 15.3 15.6 t5.9 STC:Irradance 1000 w/m'Cell Temperature 25°C,Air Mass A.1.5 according to EN 60904-3. Typical efficiency redaction of 4.5%at 200 W/m2 according to EN 60904-I. 0 "n - a 2 b 0 ELECTRICAL DATA %*OCT �� Maximum Power-Pmax(Wp) 182 186 19D 193 E t ,c Maximum Power Voitage-V.,v IV) 27,6 28.0 2$11 28.3 MULTICRYSTALLINE MODULE se<3cnouxunc eoa Maximum Power Current-Imp-(A) 6.59 6.65 6.74 6.84 WITH TRINAMOUNT FRAME 12-1-11.E "- " Open Circuit Voltage(V)4-[VJ 35,1 35.2 35,3 35.4 Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 7.27 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C.Wind Speed 1 m/s. � >� PD05.18 ^- --812 tao Back View POWER OUTPUT RANGE MECHANICAL DATA 11 Solar cells Multicrystalline 156 x 156 mm(b inches) Fast and simple to install through drop in mounting solution Celt orientation 60 cells(6 ss lO) Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 157 inches) r ov _ __ ----- _ I Weight 21.3 kg(47:0 IbsJ it Glass 3.2 mm(0,131nches),High Transmission.AR Coated Tempered Glass MAXIMUM EFFICIENCY � J A-A Backsheet 'White Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Tnnamount Groove ..._.......... I-V CURVES OF PV MODULE(245W) J Boz 1P 65 orIP 67 rayed .. Cables Photovoltaic Technology cable 4.0 mm2(0.006 inches'), __....__..... .._.._..... _........_ lo.- -__- 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 9 i Fire Rating Type Highly reliable due to stringent quality control <, A a OC Ir ru' c vT ' AAXEhJR RATINGS TEMPERAT;3 R or next o (fG^; j l , e1. e L _ 23-`[2. ,Wm m Nominal Operating Cell 44°C(+2°C) Operational Tem erature -40- 85°C . ___..__.... ....... Temperature(NOCT) o rill. , Maxim€msystem 1000V OCC ._._ 0 Temperature Coefficient of Pux 0.41%/"C Voltage 1009V DC(UL)i critical e � h C,Col ' a.. 1o.- 20.- 30.m 40.- ,�,esence oround the y Obe Ti a IS Temperature Coefficient of Vac -0.32%/°C Max Series Fuse Rating 15A r'`hls r >IV exceptional cr I varage(v) toeazh c,�lvo re 'Ch nn.. � Certified t Withstand challenging environmental Temperature Coefficient afisc 0.04�o!°C and CC5r1L [tSon§ e?0Oe,..rcc.iC11 r e k:n t r of,rims 'T :Cg L �:nkable WARRANTY 10 year Product Workmanship Warranty 1obu'Ci ng S'Ictleaic,rnuTUalili beneficial c.,lt.�:.,:.Clro. ',.i i, 25 year Linear Power Warranty ,te `elo; e ._-:`1P UIOrs (Please refer to product warranty for details) a n o9h t c s 1he - <,shared e, .-n CERVIFICAU014 0I rno.t Er','rgy T�� t1ti LINEAR PERFORMANCE WARRANTY �E SP PACKAGING CONFIGURATION 10 Year Product Warranty.25 Year Linear Power Warranty urrm Modules per box:26 pieces w Trims Solar Limited --------- ---__ p� Modules per 40"conia)ner.728pieces Add7ttonor, afu 90% @ f,---/'r1nG safQP S ffne'r Ivarranty Comv CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. "MP,L, ® ° G 2014 Trina Solar Limited.All rights reserved.Specifications Included in this datasheet are subject to N Bum }#°� r e�80% change without notice. j �.✓iii�..rct W Crx*drt NE -"lxi YZr Snact Energy Ta�£t'er Years 5 IO 15 20 25 �eMPNA' solar=@@ Single Phase Inverters for North America s o I a r r SE3000A-US%SE3800A-IJS/SE5000A-US/SE600OA-US SE760OA-US/SE10000A-US/SE1140OA-US SE30DOA US SE380OA-US SESOOOA-US SE6000A USiSE760OA-US SE10000A-US, SE1140OA-US y. __._. ......_.. .._. ..._._. ..... __... OUTPUT SolarEdge Single Phase Inverters __ 10000 @240V _ Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA Max.AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V- 12000 VA For North America 5450 @240V 10950 @240V AC Output Voltage Min.-Nom.-Max.* ✓ 183-208-229 Vac SE3000A-US/SE3800A-US/SE5000A-US;SE6000A-US i AC Output Voltage Min.-Nom Max ✓ SE760OA-US/SE10000A-US/SE1140OA-US all-zoo-z6aVac AC Frequency Mr.-Nom.-Max.* 59.3-60-60.5(with HI country setting 57-60-60.5) Hz € s- 24 @ 208V 48 @ 208V Max.Continuous Output Current 12.5 16 21 @ 240V 25 32 42 @ 240V 47.5 A GFDI 1 A Z a ,° -tt,, f �t Utility Monitoring,Islanding - - - - -� -- € ,,,. Protection,Country Configurable Yes -- .. 4 r"�., l a�3- Thresholds _ _-. ........ --- --- �_ __. _... INPUT E mt Recommended Max.DC Power -` - 3750 4750 6250 7500 9500 12400 14250 W (STC) •„`� era W i Transformer-less,Ungrounded Yes as x#Ay Max.Input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc _ N . 16.5 @ 208V 33 @ 208V #I � - 't`- �`.. Max.Input Current*** 9.5 13 15.5 @ 240V 18 23 30.5 @ 240V 34.5 Adc Max.Input Short Circuit Current 30 45 Adc „ i _ `` -Tx. Reverse-Polarity Protection Yes l �l , } Ground Detection 600kn5ensltivity �. „ n ,Maximum Inverter Efficiency 97.7 98.2 98.3 98 3 98 98 98 . .. - 97.5 @ 208V 97 @ 208V f N#° CEC Weighted Efficiency 97.5 98 98 @ 240V 97.5 97.5 97.5 @ 24 0 V 97.5 % i €. gay, a _Nighttime Power Consumption <2 5 _ <4 W rt, t i. ADDITIONAL FEATURES ._..__. _ _ _ _.... ._-_._ - ..._ ... ..._._ ._._. - ^- Supported Communication Interfaces R5485,RS232,Ethernet,ZigBee(optional) ' rf H Revenue Grade Data,ANSI C121 Optional _ _ � Ft:, '€, : R x STANDARD COMPLIANCE'-- -- - _ - -- ...... _._.._.. Safety UL1741 UL1699B,UL1998,CSA 22.2 IS fz € ;y Grid Connection Standards IEEE1547 Emissions FCC part15 class B .----__ . .---- -- �, INSTALLATION SPECIFICATIONS f ? AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8 3 AWG x`€ DC input conduit size/#of strings/ fit - AWG range 3/4"minimum/1-2 strings/24-6 AWG 3/4"minimum/1-2 strings/14-6 AWG Dimensions with AC/DC Safety 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/ 30.5 x 12.5 x 10.5/775 x 315 x 260 In/ Switch(HxWxD) 775 x 315 x 172 775 x 315 x 191 mm Weight with AC/DC Safety Switch 51.2/23.2 543/24.7 88.4/40.1 lb/kg Cooling Natural Convection - Fans(user replaceable) Noise <25 <50 dBA �h b tc irW for a rE ge enak�led` h Min-Max.Operating Temperature 13 to+140/-25 to+60(CAN version****-40to+60) F/°C Integrated 1 r fault protection(Type l)for Ni C Z011 6191D.11 compliance Range ' Superior efficiency(�$ - Protection Rating NEMA 3R Superior 'For other regional settings please contact SolarEdge support. Small,lightweight and easy to install on provided bracket "Limited to 125%for locations where the yearly average high temperature above 77'F/25'C and to 135%for locations where it is below 77'F/25'C. tl bracket ' e For detailed information,refer to hide, wwws I f - dc cu,ur,irim, i e. f - Built-in module-level monitoring A higher current source may be used,the inverter will fm t its input current to the values stated. "CAN P/Ns are eligible for the Ontario FIT and m'croF1T(microFIT en.SE11400A US-CAN). Internet connection through Ethernet or Wireless Outdoor and'indoor installation Fixed voltage inverter,DC/AC conversion only - Pre-assembled AC/D6 Safety Switch for faster installation Optional-revenue grade data,ANSI C12.1 � G ,. RoHS USA-GERMANY ITALY-FRANCE-JAPAN CHINA AUSTRALIA-THE NETHERLANDS-ISRAEL VvV>rVV,Salal"edge.uS I $Q)a r=@@ solar=es SolarEdge Power Optimizer Module Add On for North America P300 ! P350 / P400 SolarEdge Power Optimizer P300 ---P350 __..• P400 ' Module Add—On For North America ''', (for 60-cell PV (for 72-ce11 PV (for 96-ce11 PV modules) modules) modules) P300 ; P350 P400 INPUT - Rated Input DC Poweri" 300 350 400 W ® Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 Vdc Al € MPPT Operating Range 8-48 8-60 8-80 Vdc 1� Maximum Short Circuit Current(Isc) 10 Adc Maximum DC Input Current - 12.5 - Adc NE Maximum Efficiency 99.5 % Weighted Efficiency 98.8 _ % Al .R w Uvervoltage Category u p` OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) 3 ��, ME,, Maximum Output Current 15 Adc i 7 - Maximum Output Voltage _ _60 _ Vdc _OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) — -- ^ Safety Output Voltage per Power Optimizer _ 1 Vdc A 4r ' STANDARD MC „COMPLIANCE FCC PartiS Class B,IEC61000 b 2,IEC61000-6-3 ',II Safety IEC62109-1(class H safety),UL2741 � I , RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc f« Dmensions(W x I.x H) 141 x 212 x 40.5/S.SS x 8.34 x 1.59 mm/in - . � Weight(including cables) 950/2.1 gr/Ib Input Connector MC4/Amphenol/Tyco ;E ¢ ,3 Output Wire Type/Connector - Double Insulated;Amphenol li m Output Wire Length - 0.95/3.0 1.2/3.9 m/ft Operating Temperature Range -40-+85/-00-+185_ 'C F Protection Rating - IP65/NEMA4 - Relative Humidity ! 0-100 % R.,rd STC v e,onnemm�e M—Ir f p 1.11 p—, owed. j =.i. PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE , Y y INVERTER SINGLE PHASE 208V 4BOV M inimum String Length(Po wer Optimizers) 8 P }©W@I'0� ( t(kdL101 a t18 I@ , 10 18 Up to 25%.more energy Maximum String Length(Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 12750 W Superior efficiency(99.5%) Parallel Strings of Different Lengths or Orientations Yes Mitigates all types Of module mismatch losses,from manufacturing tolerance to partial shading . Flexible system design for maximum space utilization •-Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety i FRANCE: - Ai;rAi A ,v WW solxredge.us U i1 2lAr` TA I; (iv P hiv i Next-Level PV Mounting Technology SoIarCity ®pSolar Next-Level PV Mounting Technology ^SOIafClty ®pSolar 9Y it i I Zep System Components for composition shingle roofs b W, r t Gf8Ynd 2tP Irm Ock r ws 1 € i - UP C—POMW W Modow - __.. 'RaH Arradesrmr , Array x , i G0MP4T/ .F eve Description v PV mounting solution for composition shingle roofs pCpMPpS�O • Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules Auto bonding UL-listed hardware creates structual and electrical bond LISTED Comp Mount Interlock Leveling Foot Part No.850-1345 Part No.850-1388 Part No.850-1397 Listed to UL 2582, Listed to UL 2703 Listed to UL 2703 SpeCIfICBtIOnS Mounting Block to UL 2703 Designed for pitched roofs _ Installs in portrait and landscape orientations AM • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for I. This document does not create any express warranty by Zep Solar or about its products or services.Zap Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely , each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 1 of 2 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 2 of 2 i WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Lab I Location: Label Location: Code: • Per WARN NG Code: WARNING Code: NEC 9031G3 ii ELECTRIC SNACK HAZARD • ELECTRIC SHOCK HAZARD ' Dfl NOT TOUCH TERMINALS 6017.E THE DC CONDUCTORS OF THIS NEC 690.35(F) Label Location: TERMINALS flN BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN LOAD SIDES MAY BE � ENERGIZED UNGROUNDED AND PHOTOVOLTAIC DC ••- INVERTERIS -" kN THE OPEN.POSITION MAY BE ENERGIZED UNGROUNDED NEC DISCONNECT .•0 Location:Label •_ Location: PHOTOVOLTAIC POINT OF - MAXIMUM POWER-- D INTERCONNECTION _ Code: A WARNING: ELECTRIC SHOCK POINT CURRENT(Imp} Per • • •�" HAZARD. DO NOT TOUCH ' � 0 MAXIMUM PObNER--V NEC 690.53 BOTH THE LINE AND LOAD SIDE MAXIMUM SYSTEM-v MAY BE ENERGIZED IN THE OPEN VOLTAGE(Voc) POSITION. FOR SERVICE SHORT-CIRCUIT A DE-ENERGIZE BOTH SOURCE CURRENT(Isc}- AND MAIN BREAKER.. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT _ MAXIMUh�AC Label Location: OPERATING VOLTAGE V WARNING ..- ELECTRIC SHOCK HAZARD 690.5(C) iF A GROUND FAULT IS INDICATED NORMALLY GROUNDED Label L• • CONDUCTORS MAY BE CAUTION - UNGROUNDEDAND ENERGIZED' DUAL POWER SOURCE Per Code: SECOND SOURCE IS ----64.B.4 PHOTOVOLTAIC SYSTEM Label • • Per Code: Label WARNING Location: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS CAUTION ') (PO TERMINALS ON BOTH LINE AND Per ••- LOAD SIDES MAY BE ENERGIZED .PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CiRCUiT IS BACKFED NEC 690.64.13.4 DC VOLTAGE.IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNING -• Per ..- INVERTER OUTPUT Label • , • CONNECTION 690.64.B.7 AC -O DO NOT RELOCATE Disconnect DISCONNECT Per C•• THISODEVICERRENT Conduit NEC 6.0 14.C.2 (CB): Combiner C• Distribution Disconnect Interior • • Label • • Inverter - MAXIMUM AG A - Load - - OPERATING CURRENT Per Code Meter(M): Utility MAXIA�UM AC V NEC 690.54 OPERATING VOLTAGE - Point of • • 1 1 /• / a• / 1 . 1 a11117wi 1 K(aff.1 NO"2 1 a U0 4 2 11114191 •• 1• . :11116 T:(650)638-1028 F:(650)638-1029 • 1 •1 A. i N-V ' S • 1 11K:V 1 '. 1 a 1 \1 1 1 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:TLM4020 Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ISE10000A-USOOOSNR LABEL: A -(36)TRINA SOLAR # TSM-260PDO5.18 GEN #168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:85891936 Tie-In: Supply Side Connection Inverter; 100DOW, 240V, 97.57a w/Unifed Disco andZB,RGM,AFCI PV Module; 26OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 SolarCity (E) WIRING CUTLER-HAMMER Disconnect CUTLER-HAMMER 5 A 1 20OA/2P 7 Disconnect 6 00A-LI O0 DG+ MP 1 2: 1x12 B 60A SE10000A-USOOOSNR2 DG / C EGC 6 L2 DC+ i DG I N DG I `} DD MP 1: 2x12 (E) LOADS GND _ ____ GND --_ _EGG DC ---------------------- - - GEC ---T N DG DC- EGC--- --------- ------------ EGC ---------- -- I N I (1)Conduit Kit; 3/4' EMT WLIJI _J CIGEC I I I I I I GEC_r-♦ TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE I I I I I 1 I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP 0TT 2)Ground Rod; 5/8' x 8', Copper �j (1)CUTLER-HAMMER /DG222NR6, (1)SolarCfty i 4 STRING JUNCTION BOX + -�2)ILSCO IPC 4/0-16 v Disconnect; 60A, 24OVac, Fusible, NEMA 3R AC 2x2 SiItMGS UNFUSED, GROUNDED DC Insulation Piercing Connector Main 4/0-4, Tap 6-14 -(1)CUTLER- AMMER DG100NB P V (36)SOLAREDGE�300-2NA4AZS SCSUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Ground�l4eutrd t; 60-100A, General Duty(DG) PowerBox ptimizer, 30OW, H4, DC to DC, ZEP AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. -(1)Class RHF Mse�Kit DS16FK -(2)FERRAZ SHAWMUT l TR60R PV BACKFEED OCP nd (1)AWG/6, Solid Bare Copper Fuse; 60A, 25OV, pass RK5 -(1)Ground Rod; 5/8'x 8,Copper ��-(I)CUTLER-HAMMER /DG222URB (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL - i Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R -(1)GrTLE d�r MMERKik 60 BWA General Duty(DG) ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE (1 AWG/6, THWN-2, Blade (1)AWG/6,THWN-2, Black _(1)AWG#8, THWN-2 Black W_ Voc* -SOO LL VDC Ise =30 ADC (2)AWG/10.PV Wire, 600V, Blade Voc* =500 VDC Isc -15 . ADC 7 cn (1)AWG�, THWN-2, Red 6 (i)AWG/6, THWN-2, Red 4 (1)AWG#B, THWN-2, Red Vmp -350 VDC Imp-17.6 ADC i 1)AWG/6, Solid Bare Copper EGC Vmp =350 VDC Imp=8.8 ADC - 1 O�(1)AWG #6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=42 AAC O' (i)AWG/10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=42 AAC O (1 AWG 10, THMN-2, Green EGC #. . . . .. . . . . . . .. . . .. . . . .. . . .. . . . .-(1)AWG #6,.Solid Bare Copper. GEC. . . (1)Conduit.Kit;.3/4�.EMT. . . . . . . . . . . . . .. .-(1)AWG{d6,,TFLWN-2,Green . . EGC/GEC.-(1)Conduit.Kit;.3/47.EMT.. . . .. , . . . (1 AWG#10, THWN-2, Block Voc* =500 VDC Isc =15 ADC (2)AWG,1 10, PV Wire,60OV, Block Voc* =500 VDC Isc =15 ADC O (1)AWG#10, THWN-2, Red Vmp =350 VDC Imp=8.8 ADC I O (1)AWG/6,Solid Bare Capper EGC Vmp =350 VDC Imp=8.8 ADC (1)AWG/10, TIiWN-2..Green. EGC. . . . . . . . . .. .. . . .. . . .. . . .. . . . . .. . . . . . ���JJJ . . . .. (2)AWG#10, PV Wire,60OV, Blade Voc* =500 VDC Isc =15 ADC O (1)AWG,}6,Solid Bore Copper EGC Vmp =350 VDC Imp=8.8 ADC . . .. . . . . .. . . . . . . .. . .. . .. . . .. . . .. .. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMJ B-01010 9 8 00 PREMISE OWNER: DESC ION.. DESIGN: BER: ., o�arClty CONTAINED SHALL NOT BE USED FOR THE PREMO, GREG PREMO RESIDENCE Mehul Dalai .,�. , BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: I•�: ,S NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 46 SANDY HILL RD 9.36 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH ' 24 St Martin Drive.Building Z Unit 11 THE SALE AND USE OF THE RESPECTIVE (36) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME SHEET: REV DATE Morlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER. T: (650)638-1028 R (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE1000OA-USOOOSNR2 413-221-0270 THREE LINE DIAGRAM PV 4 6/9/2015 (e6B)-SOL-CITY(765-2489) www.solarcitycom S1 S 1 (E) 2x4 » ` (E) 2x4 5'-11" 5'-2" 1'- (E) LBW 5'-3„ l'-21 (E) LBW SIDE VIEW OF MP1 N-rs SIDE VIEW OF MP2 NTS A g MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 7211 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 4811 17" PORTRAIT 48" 17" TOP CHORD 2X4 @ 24 OC ROOF AZI 158 PITCH 19 STORIES: 1 TOP CHORD 2x4 @ 24" OC ARRAY AZI 338 PITCH 19 STORIES: 1 ARRAY AZI 158 PITCH 19 B BOT CHORD 2X4 @24" OC Comp Shingle OT CHORD 2X4 @24" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH STAMPED & SIGNED FOR POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. STRUCTURAL ONLY (E) COMP. SHINGLE (4) PLACE MOUNT. (E) ROOF DECKING (2) (5) � 5/16" DIA STAINLESS (5) INSSEALINGGWASHER.NTH STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES « ' WITH SEALING WASHER (6) INSTALL LEVELING FOOT WITH N (2-1/2" EMBED, MIN) BOLT & WASHERS. il10 (E) RAFTER .a lot TV S 1 STAN DOFF �1� A1�,.y CONFIDENTIAL— THE INFORMATION HEREIN FINVERTER: J B-0101098 00 OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT E USED FOR THE PREMO, GREG PREMO RESIDENCE Mehul Dalal �;;;SO�afCit�/. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., : �.,; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN unt Type C 46 SANDY HILL RD 9.36 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION IMTH > THE SALE AND USE OF THE RESPECTIVE A SOLAR # TSM-260PDO5.18 24 St Martin Drive,Building 2 Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: Marlborough,MA 01752 PERMISSION OF SOLARCITY INC. T. (650)638-1028 F-. (650)638-1029 E SE1000OA—USOOOSNR2 413-221-0270 STRUCTURAL VIEWS PV 3 6/9/2015 (888)-Sa—CITY(765-2489) www.solarcity.com PITCH: 19 ARRAY PITCH:19 MP1 AZIMUTH: 158 ARRAY AZIMUTH: 158 a 0 MATERIAL:Comp Shingle STORY: 1 Story Digitally signed by Marcus Hann r5 '� PITCH: 19 ARRAY PITCH:19 MP2 AZIMUTH:338 ARRAY AZIMUTH:338 Date:2015.06.10 14:22:23-04'00' 1� MARCUS � MATERIAL:Comp Shingle STORY: 1 Story RAM .2W11 City of Northampton its r �' Inv M Building Department ' SAL` , Plan Review _�� � D 212 Main Street Northampton, 01060 Zcl W ti STAMPED & SIGNED FOR el — I --- / STRUCTURAL ONLY - ----------- LEGEND 0 (E) UTILITY METER & WARNING LABEL MP ln� INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS A AC DISCONNECT & WARNING LABELS Front Of House Q DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS (E) DRIVEWAY LG LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER 46 Sandy Hill Rd STANDOFF LOCATIONS _ _ ` CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED 7A, { SITE PLAN N r Scale: 1/8" = 1' p 1' g' 16' F J B-0101098 0 0 PREwsE°"N� DESCRIPTION: DESIGN: CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: ��►!� CONTAINED SHALL NOT BE USED FOR THE PREMO, GREG PREMO RESIDENCE Mehul Dala1 .�i3O�ar•('I}" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNIWG SYSTEM: �•�� ` 1.re NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 46 SANDY HILL RD 9.36 KW PV ARRAY PART To OTHERS OUTSIDE THE RECIPIENT'S FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (36) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME: SHEET: REV: DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 91VFRTlR T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE1000OA—USOOOSNR2 413-221-0270 SITE PLAN PV 2 6/9/2015 (888)-SOL-OTY(765-2469) www.90arcitycom ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING City of Northampton DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN Building Department EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. Plan Review (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING 212 Main Street EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, Northampton, MA 01060 FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(8). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION #a ELEC 1136 MR OF THE MA STATE BUILDING CODE. r 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING , MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-0101098 00 PREMISE OYRNER. DESORPTION: DESITYI. CONTAINED SHALL NOT BE USED FOR THE PREMO, GREG PREMO RESIDENCE Mehul Dalal ��,�'`a ' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �;;;So�arCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp ount Type C 46 SANDY HILL RD 9.36 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S TMK OWNER: ORGANIZATION, EXCEPT IN CONNECTION MATH MODULES FLORENCE, MA 01062 * 24 St.Martin Drive.Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (36) TRINA SOLAR # TSM-260PDO5.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN- PAGE NAME: SHEET: REV' DATE M 38-1028 MA 50) PERMISSION OF SOLARCITY INC. INVERTER' T: (650)636-1028 F. (650)638-1029 SOLAREDGE SE1000OA—USOOOSNR2 413-221-0270 COVER SHEET PV 1 6/9/2015 (aBB)—soL-aTY(Zas-2as9) www.solarcity.com CALCULATION OF DESIGN WIND LOADS- MP2 Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware. Comp Mount;Tyoe-C Roof Slope 190 Rafter Spacing 24"O.C. Framing Type/Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic Factor Krt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-118/C/D-14A/B Ext. Pressure Coeffident Down G p 0.45 Fig,6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure Up Pfun) -13.1 psf Wind Pressure Down 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -223 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 44.5% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -247 lbs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 49.4% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP2 Member Properties Summary MP2 Horizontal Member Spans Rafter Pro Parties Overhang 1.16 ft Actual W 1.50" Roof System Pro e Span 1 5.86 ft Actual D 3.50" Number of Spans(w/o Overhang) 2 San 2 5.22 ft Nominal Yes R Material Comp Roof Span 3 A 5.25 in.^2 Re-Roof No Span 4 S. 3.06 in.^3 Ply�ood Sheathing Yes Span 5 1 5.36 in.^4 Board Sheathing None Total Span 12.24 ft TL Defl'n Limit 120 Vaulted Ceffing No PV 1 Start 8.17 ft Wood Species MSR Ceiling Finish 1/2"Gypsum Board PV 1 End 11.33 ft Wood Grade Rafter Slope 190 PV 2 Start Fb 1650 psi Rafter Spacing 24" O.C. PV 2 End F„ 160 psi Top Let Bracing Full PV 3 Start E 1500000 psi Bot Lat Bracing At Supports PV 3 End Emin 766000 psi Member Loading Summa Roof Pitch 4/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 9.0 psf x 1.06 9.5 psf 9.5 psf PV Dead Load PV-DL 3.0 psf x 1.06 3.2 psf; Roof Live Load RLL 20.0 psf x 1.00 20.0 psf Live/Snow Load LL/SL i Z 40.0 psf x 0.7 1 x 0.7 28.0 psf 28.0 psf Total Load(Governing LC TL 37.5 Psf 40.7 psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-21 2. pf=0.7(Q(Ct)GO p9; Ce=0.9,Ct=1.1,I5=1.0 Member Design Summa (per NDS Governing Load Comb I CD CL + CL - CF Cr D+ S 1 1.15 1.00 1 0.96 1 1 1.15 Member Anal sis Results Summary Maximum Max Demand 0 Location Capacity DCR Load Combo Shear Stress 68 psi 1.2 ft. 184 psi 0.37 D + S Bending + Stress 635 psi 3.6 ft. 2182 psi 0.29 D + S Bending - Stress -1112 psi 7.0 ft. -2093 psi 0.53 D+ S Total Load Deflection 0.1 in. I .L/716 3.7 ft. 0.62 in. I L4120 0.17 D+Lr CALCULATION OF DESIGN WIND LOADS- MPi Mounting Pane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTm Spanning Vents No Standoff Attachment Hardware Comp MountType C Roof Slope 190 Rafter Spacing 24"O.C. Framing Type Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig. 6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 15 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.85 Table 6-3 Topographic factor Kn 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 15.0 psf Wind Pressure Ext. Pressure Coefficient U GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down GC Down 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p =qh(GC) Equation 6-22 Wind Pressure Up P003 -13.1 psf Wind Pressure Down 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -223 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 44.5% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -247 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 49.4% STRUCTURE ANALYSIS- LOADING SUMMARY AND MEMBER CHECK- MP1 Member Properties Summary MP1 Horizontal Member Spans Rafter Pro Parties Overhang 1.16 ft Actual W 1.50" Roof System Properties Span 1 5.89 ft Actual D 3.50 Number of Spans w/o Overhang) 2 San 2 5.19 ft Nominal Yes Roofing Material Comp Roof Span'3 A 5.25 in,^2 Re-Roof No Span 4 S. 3.06 in.^3 Sheatiflng Yes Span 5 I 5.36 in.",4 Board Sheathing None Total Span 12.24 ft TL DefPn Limit 120 Vaulted Ceiling No PV I start 1.92 ft Wood Species MSR Ceiling Finish 1/2"Gypsum Board PV 1 End 11.33 ft Wood Grade Rafter Slope 190 -PV 2'-Start Fb 1650 psi Rafter Spacing 24"O.C. PV 2 End F„ 160 psi Top Bracing Full PV 3 Start E 1500000 psi Bot Lat Bracing At Supports PV 3 End Emir 766000 psi Member Loading Summa Roof Pitch 4/12 Initial Pitch Adjust Non-PV Areas PV Areas Roof Dead Load DL 9.0 psf x 1.06 9.5 psf 9.5 psf PV Dead Load -PV-DL 3.0 psf x 1.06 3.2 psf Roof Live Load RLL 20.0 psf x 1.00 20.0 psf Live/Snow Load LL SL1,2 40.0 psf x 0.7 1 x 0.7 28.0 psf 28.0 psf Total Load(Governing LC TL 1 37.5 psf 40.7 osf Notes: 1. ps=Cs*pf;Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Ce)(Ct)(IS)p9; Ce=0.9,Ct=1.1,I5=1.0 Member Design Summa (per NDS Governing Load Comb I CD CL + CL - CF Cr D+S 1 1.15 1.00 1 0.96 1 1 1 1.15 Member Anal sis Results Summary Maximum Max Demand 0 Location Capacity DCR Load Combo Shear Stress 71 psi 1.2 ft. 184 psi 0.39 D + S Bending +)Stress -722 psi 3.6 ft. 2182 psi 0.33 D+S Bending - Stress -1175 psi 7.1 ft. -2093 psi 0.56 D+ S Total Load Deflection 0.12 in. I L/611 3.8 ft. 0.62 in. 120 0.20. D+ S 06.10.2015 SolarCiPV't , System Structural Version#46.4 Design Software PROJECT INFORMATION &TABLE OF CONTENTS Project Name: Premo Residence AHJ: Northampton Job Number: 0101098 Building Code: MA Res. Code, 8th Edition Customer Name: Premo,Greg Based On: IRC 2009/IBC 2009 Address: 46 Sandy Hill Rd ASCE Code: ASCE 7-05 City/State: Florence, MA Risk Category: II Zip Code 01062 Upgrades Req'd? No Latitude/Longitude: 42.323505 -72.681225 Stamp Req'd? Yes SC Office:I Springfield I PV Designer:I Mehul Dalal Certification Letter 1 Project Information, Table Of Contents, &Vicinity Map 2 Structure Analysis (Loading Summary and Member Check) 3 Hardware Design (PV System Assembly) 4 Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22424< 0.4g and Seismic Design Category(SDQ = B < D 1/2-MILE VICINITY MAP 0 Q 0 cwl a�> -1 M 0 'a th of Massachusetts EOEA, U.S. Geological Survey, USDA Farm Service Agency 46 Sandy Hill Rd, Florence, MA 01062 Latitude:42.323505, Longitude: -72.681225, Exposure Category: C Version#46.4 � SolarCit OF AV June 10, 2015 cus H ANN Project/Job#0101098 NO.2991$ � RE: CERTIFICATION LETTER ;TV+�' Project: Premo Residence ��v' 46 Sandy Hill Rd } f Florence, MA 01062 To Whom It May Concern, A jobsite survey of the existing framing system was performed by a site survey team from SolarCity. Structural review was based on site observations and the design criteria listed below: Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed =90 mph, Exposure Category C -Ground Snow Load =40 psf - MP1: Roof DL= 9 psf, Roof LL/SL= 28 psf(Non-PV Areas), Roof LL/SL= 28 psf(PV Areas) - MP2: Roof DL= 9 psf, Roof LL/SL= 28 psf(Non-PV Areas), Roof LL/SL= 28 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22424< 0.4g and Seismic Design Category(SDC) = B < D On the above referenced project,the components of the structural roof framing impacted by the installation of the PV assembly have been reviewed. After this review it has been determined that the existing structure is adequate to withstand the applicable roof dead load, PV assembly load,and live/snow loads indicated in the design criteria above. I certify that the structural roof framing and the new attachments that directly support the gravity loading and wind uplift loading from PV modules have been reviewed and determined to meet or exceed structural strength requirements of the MA Res. Code, 8th Edition. Please contact me with any questions or concerns regarding this project. Sincerely, Marcus Hann, P.E. Professional Engineer Digitally signed by Marcus Hann T: 888.765.2489 Date:2015.06.10 14:16:40-04'00' email: mhann @solarcity.com 3055 Clearview Way San Mateo.CA 94402 T(650)638-1028 (888)SOL.-CITY F(650)638-1029 solarcity.com DocuSign Envelope ID:841625AA-5D26-4057-BFCO-4581AB9EODC9 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in their YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR TO entirety and I acknowledge that I have received a complete copy of this MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE Power Purchase Agreement. YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name: Sarah Chyla EXPLANATION OF THIS RIGHT. DocuSigned by: 24.ADDITIONAL RIGHTS TO CANCEL. Signature: y' 3 IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: 6/1/2015 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricin The pricing in this PPA is valid for 30 days after 6/1/2015. If you Customer's Name: Gregory Premo don't sign this PPA and return it to us on or prior to 30 days after DocuSigned by: 6/1/2015, SolarCity reserves the right to reject this PPA unless you Signature: agree to our then current pricing. Date: 6/1/2015 ,5olarCity. Power Purchase Agreement SOLARCITY APPROVED Signature: LYNDON RIVE, CEO (PPA) Power Purchase Agreement .*M!- w Date: 6/1/2015 ❑ m ❑� Ss ar Po imer P_m hase.Agreement ,erw:1 8.4.1 825:33 W 9 . DocuSign Envelope ID:841625AA-5D26-4057-BFCO-4581AB9EODC9 i,, SolarCity. Power Purchase Agreemel L Here are the key terms of your SolarCity Power Purchase Agreement Date:_6111 5 $0 l7n230 20years System Installation cost Electricity rate per kWh Agreement term Our Promises to You • We insure,maintain,and repair the System(including the inverter)at no additional cost to you,as specified in the agreement. • We provide 2417 web-enabled monitoring at no additional cost to you,as specified in the agreement. • We warranty your roof against leaks and restore your roof at the end of the agreement, specified in the agreement. • The rate you pay for electricity,exclusive of taxes,will remain fixed for the term of tee agree,ment. • The pricing in this PPA is valid for 30 days after 61112015. • We are confident that we deliver excellent value and customer servtay pia result,ycu are free ito cancel anytime at no charge prior to construction on your home: - Estimated'First Year Production 8;355 kWh Amount due at contract signing: $0 ,,�,.. Estimated prepayment due when installation begins. $0.00 Estimated prepayment due following building inspection $0.00 Customer's Name & Service Address Exactly as it appears on the utility bill Customer Name and Address Customer Name Installation Location Sarah Chyla Gregory Premo 46 Sandy Hill Rd 46 Sandy Hill Rd Florence, MA 01062 Florence, MA 01062 Options for System purchase and transfer: Options at the end of the 20 year term: • If you move,you may transfer this agreement to the purchaser of your • SolarCity will remove the System at no cost to you. Home,as specified in the agreement. . You can upgrade to a new System with the latest solar • At certain times,as specified in the agreement,you may purchase the technology under a new contract. System. • You may purchase the System from SolarCity for its fair • These options apply during the 20 year term of our agreement and not market value as specified in the agreement. beyond that term. • You may renew this agreement for up to ten(10)years in two(2)five(5)year increments. 3055 CLEAHVIEW WAY, SAN MAi EO, CA 94402 888.SOL.CITY ( 888.765.2489 1 SOLARCITY.COM MA HIC 16857 2`Et-1136MR Document Generated on 61112015 QQ 8254:t3 UN ■ WdA Office of Consumer Affairs sand Business iegulation Y 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card SOLAR CITY CORPORATION Expiration: 3/8/2017 VICTORIA JU NC K -------------- --- ---- _ - -— —— 3055 CLEARVIEW WAY SAN MATEO, CA 94402 ---------- Update Address and return card.Mark reason for change. a Q '^ r5 ;— Address ~ Renewal Employment i Lost Card - - - Office of Consumer Affairs&Business Regulation License or registration valid for individul use only ME IMPROVEMENT CONTRACTOR before the expiration date. if found return to: z Registration: 168572 Type; Office of Consumer Affairs and Business Regulation 10 Park Plats-Suite 5170 Expiration: 3/8/2017 Supplement::and Boston,MA 02116 SOLAR CITY CORPORATION VICTORIA JUNCK 24 ST MARTIN STREET BLD 2UNI ���-- - ITAAhLBOROUGH,MA 01752 Undersecretary Not valid without ' Store fxf��+ ( �� Office of Consumer Affairs and Business Regulation .4 10 Park Plaza - Suite 5170 4p Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 168572 Type: Supplement Card Expiration: 3/8/2017 SOLAR CITY CORPORATION CRAIG ELLS - 3055 CLEARVIEW WAY SAN MATEO, CA 94402 -- Update Address and return card.Hark reason for change. Address Renewal Employment Lost Card office or Consumer AMIrs&Business Regulation License or registration valid for individul use only Si before the expiration date. If found return to: r HOME IMPROVEMENT CONTRACTOR r Office of Consumer Affairs and Business Regulation m Registration: 168572 Type: 10 Park Plaza-Suite 5170 Expiration: 31812017 Supplement Card Boston,MA 02116 SOLAR CITY CORPORATION CRAIG ELLS 24 ST MARTIN STREET BL0 2UNI / 4 ° KiAhLBOROUGH,MA 01752 Undersecretary Not vaiid without signature 3 CS-107663 CRAIG ELLS 206 BAKER STREET Keene NI-11 03431 08129!2017 ACD d CERTIFICATE OF LIABILITY INSURANCE OTE(MMIDWYYIY) 08129f2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemen s. PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES 345 CALIFORNIA STREET,SUITE 1300 PH_�A! bo, CALIFORNIA LICENSE NO.0437153 MAIL - -- SANFRANCISCO,CA 94104 INSRR 1AJ8L FFORDING COVERAGE __NAIC 0 998301-STND-GAWUE 14.15 - .,.--_,-_-- INSURER A Liberty Mutual Fire losurance Company 16586 INSURED INSURERS:Liberty Insurance Corporation l42404 Ph(650)963-5100 -- SolarGty Corporation INSURER C:WA NIA 3055 Clearview Way - ---- __-_ ---. -._ --� .. y INSURER D: _- -- --_- San Mateo.CA 94402 - ------ ----- ---- INSURER E INSURER : COVERAGES CERTIFICATE NUMBER: SEA-002440269-02 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS. EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IN$R TYPE OF INSURANCE ADDL UBR POLICY NUMBER POLICY EFF MOUCY Y LIMITS A GENERAL LIABILITY T82-661-066265-014 09101/2014 09/0112015 1.�.� _EACH OCCURRENCE $ �AMAGI TO to ELATED - -- X C_OMMERCIAL GENERAL_LIABILITY PFIEMISES AQwAEenCel _ $ _ 1�' CLAIMS-MADE X OCCUR i MED EXP IAN"Person) 1 PERSONAL d ADV INJURY ($ - GENERAL AGGREGATE 13 2,000,0_ GEN'L AGGREGATE LIMIT APPLIES PER. PRODUCTS•COMPIOP AGG S 2,000,000 X POLICY X PRO- LOC Deductible $ 25,000 A AUTOMOBILE LIABILITY AS2.661-066265-044 09/01/2014 09/0112015 COMBINED SIN LIMI i - (Fe aocident)__ --__ 3 X ANY AUTO BODILY INJURY(Per person) $ - ALL OWNED SCHEDULED DILYINJURY(Paraccident) $ F X AUTOS X NON OWNED P BOROPERTY DAMAGE $AUTOS HIRED AUTOS -Peroomd-opt) ___ _ _ X Phys.Damage COMPICOLLDED: $ $1,0001$1,000 UMBRELLA UAB I OCCUR ` EACH OCCURRENCE $ EXCESS UAB 1 CLAIMS-MADE `AGGREGATE $ _ D D RETENTION — $ B WORKERS COMPENSATION WA7-66D-066265-024 0910112014 09/01/2015 X WCSTATU- OTH•, AND EMPLOYERS'LIABIUTY _TORY LIMIT;z1 I ER B r r N WC7-661-066265-034(WI) 0910112014 09/01/2015 $ 1,000,000 ANY PROPRIETORIPARTNER/EXECUTIVE � E L EACH ACCIDENT OFFICERIMEMBER EXCLUDEDO) M LA� ---- --- -- B WC DEDUCTIBLE:$350,000 ' 1000,000 (Mandatory In NH) _E L DISEASE EA EMPLOYEE_$ If yes.describe under - -- ---- DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ 1'�'000 i I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,U more space Is required) Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SolarClty Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clearvim Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 94402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Charles Marmolejo ®1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations r I Congress Street,Suite 100 Boston,MA 02114-2017 r `"t °'' wwtumassgov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Busineworganizmion/individual): SOLARCITY CORP Address:3055 CLEARVIEW WAY City/State/Zip:SAN MATEO, CA 94402 Phone#:888-765-2489 Are you an employer?Check the appropriate box: Type of project(required): 1.® I am a employer with 5000 4. ❑ 1 am a general contractor and 1 employees(full and/or pate-time).* have hired the sub-contractors 6. El New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑Demolition working for me in any capacity. employees and have workers' [No workers' comp. insurance comp. insurance.; 9. ❑ Building addition required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 1 l.[]Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.]t c. 152,§1(4),and we have no SOLAR/PV employees. [No workers' 13.X Other comp. insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation hisurance for my employees. Below is the policy and job site Information. Insurance Company Name:LIBERTY MUTUAL INSURANCE COMPANY Policy#or Self-ins. Lic. #::WQ A7-66D-066265-024 _ Expiration Date:09/01/2015 Job Site Address: 'D- t k B City/State/Zip: _ N- ,Q A NUO/_ Attach a copy of the workers' compensation. licy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and enaldes of perjury that the Information provided above Is true and correct. o;ttC. Phone#: O f elal use only. Do not write In this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3.City/Town Clerk 4.Electrical Inspector S.Plumbing Inspector 6.Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Address /i / Expiration Date 978-875-1698 Signature / Telephone 9.Re llatered Home Improvement Contractor: Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2017 Address _ Expiration Date ,- Telephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner Exempti©n The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding[ ] Other❑✓ Brief Description of Proposed 3(.1(11 Work: Install solar electric panels to roof of existing home.to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No ' Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or add on to existing hous ng,complete the follow nd: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Greg Premo as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 06/12/2015 Signature of Owner Date SOLARCITY CORPNICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORPNICTORIA JUNCK Print Narpe 06/12/2015 Signature of Owner/Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. D+rrtt�at�� i�` N � City of Northampton �'' Q` �rh ilding Department � �t 1 212 Main Street vat1 J _ UN 52% Room 100 W II TY hampton, MA 01060 7 of Ei8C1("lu �� Fri�rr b;, e 13 587-1240 Fax 413-587-1272 , Gas Inspectionstti, APPLICATION TO CONSTRUCT,ALTER,REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 46 Sandy Hill Rd Map Lot Unit Zone Overlay District Elm St District CS District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Greg Premo 43 Sandy Hill Rd Northampton,MA 01060 Name(Print) Current Mailing Address: 413-221-0270 Telephone Signature 2.2 Authorized Aaent: SolarCity CorpNictoria Junck 604 Silver St Agawam MA 01001 Name ri W, Current Mailing Address: ai 978-215-2367 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building 7,000 (a)Building Permit Fee 2. Electrical (b) Estimated Total Cost of 17,000 Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total=0 +2+3+4+5) 24,000 Check Number This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2015-1307 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAM01001 (888)765-2489(2358) PROPERTY LOCATION 46 SANDY HILL RD MAP 29 PARCEL 404 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building;Permit Filled out Fee Paid Typeof Construction: INSTALL ROOF MOUNTED 36 PANELS 9.36 KW SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building-Plans Included: Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: roved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolif n �---- J Si e of Bui ing fficfal Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 46 SANDY HILL RD BP-2015-1307 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:29-404 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2015-1307 Project# JS-2015-002399 Est.Cost: $24000.00 Fee: $168.00 PERMISSION IS HEREB Y GRANTED TO: Const.Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq. ft.): 22869.00 Owner: PREMO DOUGLAS H C/O GREGORY J PREMO Zoning: Applicant. SOLARCITY CORP AT: 46 SANDY HILL RD Applicant Address: Phone: Insurance: 604 SILVER ST (888) 765-2489 (2358) Workers Compensation AGAWAMMA01001 ISSUED ON:611612015 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 36 PANELS 9.36 KW SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType• Date Paid: Amount: Building 6/16/2015 0:00:00 $168.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner