Loading...
36-214 (8) F 0 R T E MEMBER REPORT Level,Floor:Drop Beam PASSED 3 piece(s)13/4"x 117/8"2.0E MicrollamO LVL r� Overall Length: 15' 1" V 0 - o 4 14'6" c n All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. DeSi n Resu(1s Actual 0 Loatlon Allowed Result LDF Load,Combination(Pattern) System:Floor Member Reaction(Ibs) 5620 @ 2" 7809(3.50") Passed(72%) -- 1.0 D+1.0 L(All Spans) Member Type:Drop Beam Shear(Ibs) 4665 @ V3 3/8" 11845 Passed(39%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential Moment(Ft-Ibs) 20266 @ 7'6 1/2" 26772 Passed(76%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC Live Load Deft.(in) 0.435 @ T 6 1/2" 0.492 Passed(L/407) 1.0 D+1.0 L(All Spans) Design Methodology:ASD Total Load Defl.(in) 0.579 @ 7'6 1/2" 0.738 Passed(L/306) 1.0 D+1.0 L(All Spans) • Deflection criteria:LL(L/360)and TL(L/240). Bracing(Lu):All compression edges(top and bottom)must be braced at 14'6 3/4"o/c unless detailed otherwise.Proper attachment and positioning of lateral bracing is required to achieve member stability. Bearing L-90 LOS&to Supports(Ilwj sumofft TOW Avoll" Requked Dead Ltm TOW AcMil ies 1-Stud wall-SPF 3.50" 3.50" 2.52" 1397 4223 5620 Blocking 2-Stud wall-SPF 3.50" 3.50" 2.52" 1397 4223 5620 Blocking •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Tributary Dead Floor Live Le11Bf1s? Location Wktth (0.90) (1.00) Comments 1-Uniform(PSF) 0 to 15'1" 6' 12.0 40.0 Residential-Living Areas 2-Uniform(PSF) 0 to 15'1" 8' 12.0 40.0 Residential-Living Areas Member Notes 24 Birch Lane Bonde 535-9529 Assumes 2nd floor load only,no roof or attic load. f� weyerhmmillwilll SUSTAINABLE FORESTRY INITIATIVE Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. l Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com)Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Use of this software is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is responsible to assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. The product application,input design loads,dimensions and support information have been provided by Dave Fagnand rForte Software Operator Job Notes 6/5/2015 11:04:28 AM Nat---ha--n Grade------ ------ --------------- -- -- -- ---� Forte v4.6,Design Engine:V6.1.1.5 Bluelinx (888)676-9497 nathan.grade @bluelinxcacom Page 1 Of 1