17C-211 (12) ' 780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS
MEANS OF EGRESS
width. Handrail projections are permitted in 1011.3.1 Capacity: The required capacity of a
accordance with 780 CMR 1022.2.1. corridor shall be determined by dividing the
occupant load that utilizes the corridor for exit
1011.2 Dead ends: exit access passageways and access by the number of exits to which the
corridors in all stories which serve more than one corridor connects, but not less than the capacity
exit shall provide direct connection to such exits in
of the exit element to which the corridor leads.
opposite directions from any point in the
passageway or corridor insofar as practicable. The 1011.4 Enclosure: All corridors shall be
length of a dead-end passageway or corridor shall eresistance rated in accordance with Table 1011.4
not be more than 20 feet(6096 mm). aced on the use group of the space and the total
Exceptions: required capacity of all of the exits from the
1. In occupancies in Use Group I-3 of Occupancy corridor. The corridor walls shall comply with
Conditions II,III or IV(see 780 CMR 308.4),the 780 CMR 711.0.
dead end in a corridor, hallway or aisle shall not
exceed 50 feet(15240 mm). ceptions: -..
1. A fireresistance rating is not required for
2. In occupancies in Use Group B where corridors in an occupancy in Use Group E where
passageways are bounded by furniture, counters, each room that is occupied for instruction or
partitions or similar dividers not more than six assembly purposes has at least one-half of the
feet(1829 nun)in height,the length of a dead-end required means of egress doors opening directly
passageway shall not be more than 50 feet(15240 to the exterior of the building at ground level.
mm)' 2. A fireresistance rating is not required for
3. Passageways or corridors within spaces with
' l�l corridors contained within a dwelling unit or a
o e means of egress.
1 v,1p a y° 4. A dead-end passageway or corridor sJn guestroom in an occupancy in Use Group R.
�{ be limited in length where the length of thr(' I end passageway or corridor less than 2 Table 1011.4
CORRIDOR FIRERESISTANCE RATING
tlte least width of the dead-end passage
Corridor. Required fireresistance rating
�l Total required (hours)
1011.2.1 Common path of travel: In Use pup capacity of all
occupancies in Use Group B, the length of a exits from Without With sprin1der
common path of travel shall not exceed 75 feet corridor kler System
(22860 mm). H-1,H-2,H-3 All I I
Exceptions: H-4 >30 1 1
1. The length of a common path of travel in an 00
occupancy in Use Group B shall not be more g S
than 100 feet (30480 mm), provided that the I-1 Ra >10 1 a
building is equipped throughout with an 1-2 All I Ob
automatic sprinkler system installed in 1-3 All Not permitted 0c
accordance with 780 CMR 906.2.1. Note a. For a reduction in the fireresistance rating for
2. Where a tenant space in an occupancy in occupancies in Use Group R, see 780 CMR 1011.4,
Use Group B has an occupant load of not more Exception 2.
than 30,the length of a common path of travel Note b. For requirements for occupancies in Use
shall not be more than 100 feet(30480 mm). Group I-2,see 780 CMR 409.3.
Note c. For a reduction in the fireresistance rating for
1011.3 Width: The minimum required width of occupancies in Use Group I-3,see 780 CMR 410.7.
Note d. buildings equipped throughout with an
passageways,aisle accessways,aisles and corridors
automatic sprinkler system in accordance with 780 CMR
AcAl shall be determined by the most restrictive of the 906.2.1 or 906.2.2.
following criteria:
( 1. 44 inches (1118 mm) where serving an 1011.4.1 Corridor walls as separation walls:
occu ant load of eater Tenant and dwelling unit separation walls which
--� 2`. 36 me es(914 mm)where serving an occupant are also corridor walls shall comply with
load of 50 or less. 780 CMR 1 101.0 and the requirements of Table
inches(2438 mm)in an occupancy in Use 602.
Group I-2 used for the movement of beds. Exception: Tenant separation and dwelling
4. 72 inches(1829 mm)in an occupancy in Use unit separation walls which are also corridor
Group E with more than 100 occupants. walls shall not be required to have a
S. The width required for capacity as determined fireresistance rating greater than that required
by 780 CMR 1009.0. by Table 1011.4 where the building is
Aisles and aisle accessways shall conform to the equipped throughout with an automatic
requirements of 780 CMR 1011.0 or 780 CMR sprinkler system in accordance with 780 CMR
1012.0. 906 2 1 or 906.2.2.
2/7/97 (Effective 2/28/97) 780 CMR-Sixth Edition 179
r
f �
CITY OF NORTHAMPTON
1T ? MASSACHUSETTS
L
CITY HALL
210 Ma(n Street
Northampton, MA 01060
(413) 586-6950
FAX: (413) 587-1264(Ma i n Bldg. )
FAX TRANSMITTAL
DATE: Q Z�
FAX TO TELEPHONE NUMBER: /03 — 92-6 — /O
TO:
FROM:
Phone Number: 413-.587-1240
FAX Number: 4 13— 587-1272 (Annex)
RE: /0//o -3 O cm'.q
PAGES, INCLUDING THIS SHEET:
9vg's776-3 -.
1_
Anthony L. Patillo, CBO
Building Commissioner
Zoning Enforcement Officer
212 Main Street- Room 100 587-1240
Northampton, MA 01060-3189 Fax 587-1272
1
}uRI - Cap
E=IROYAL 4
DESIGN■BU IL®ERS
.Tulle 4. 2002
Mr. Anthony Patillo
Northampton Building Inspector
212 Main Street
Room 100
Building Department
Northampton, MA 01060
VTA FAX:413-587-1272
Re: Florence Savings Main Office
Dear Tony,
It has rceently come to my attention that while you were inspecting the project, you made a
comment about the clear openings that had been established between the nc% building and addition
along the egress path. 521 CMR section 26.1.1 allows for a clear opening oi'32" as long as the
depth of the opening is 24"or less. In both cases were this exists at the bank, the openings are at
least 32"clear and no more than IS" deep_ T believe we fall under this exception according to 521
CMR. Please let inc know if you do not concur.
8inccreiy,
r
Bourbeau, AIA
Director of Architectural Services
PHH: pc
C'c: john I ieal-3s,Janet Clay, Ted Vrettos and Jim Schwartz,