23B-066 (4) 13/52 Rail LRFD Allowable Uplift Wind Force(plf) Rail Span(ft) 70 80 90 100 110 130 150 170 200 240 300 380 480 650 900 3.0 13/52 Rail 3.5 13152 Rail 4.0 13152 Rail 4.5 13/52 Rail 5.0 13/52 Rail 5.5 13/52 Rail 6.0 13/52 Rail 6.5 13/52 Rail 7.0 13/52 Rail 7.5 13/52 Rail 8.0 13152 Rail 8.5 13152 Rail 910 13/52 Rail 13/52 Rail 10.0 13/52 Rail 13/52 Rail LRFD Allowable Uplift Span(ft) Force(lb) 3.0 1764 3.5 1480 4.0 1243 4.5 1101 5.0 960 5.5 838 6.0 756 6.5 690 7.0 651 7.5 598 8.0 533 8.5 510 9.0 480 9.5 444 10.0 402 13/52 Rail Zone 3 Span Chart Exposure Wind Ground Snow Load Speed 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 85 6.5 6.5 6.5 6.0 5.5 5.0 4.5 4.0 4.0 3.5 100 6.0 6.0 6.0 5.5 5.0 4.5 4.5 4.0 4.0 3.5 110 5.5 5.5 5.5 5.5 5.0 4.5 4.5 4.0 4.0 3.5 Category 120 5.0 5.0 5.0 5.0 5.0 4.5 4.5 4.0 4.0 3.5 B 130 5.0 5.0 5.0 5.0 5.0 4.5 1 4.5 4.0 4.0 3.5 140 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.0 4.0 3.5 150 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.5 160 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.5 Exposure Wind Ground Snow Load Speed 0 psf 10 psf 20 psf 30 psf 40 psf 1 50 psf 60 psf 70 psf 80 psf 90 psf Exposure Wind Ground Snow Load Speed 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 85 5.0 5.Q 5.0 50 -5.0. 4S< ;4.5 4.0 4,0 3.5 100 5.0 5.0 5,0, 5..0 5.0_ 4ar � -AS � 4:0 4.0 3.5 110 4.5 4.5 4.5 4;5 4:5 4.5 4s,.. . 4.0_S . 4.0' 3.5 Category 120 4.0 4.0, 4.0 40 4.0 4.0' 1, 4.0 4:0 4.0 3.5 O 130. 410 4.0 .. 4.0. 40 d0 _,` 40 .:_: 40 . a a.. 4Q .. 4.0 3.5 140 3.5 , 3:5 3,5 35. 5 : 3 `' r 3.5 ' , . 3.5' 3.5 150 3.5 3.5 3.5 3.5 3.5 3.5 3t$ 3,5 3.5 3.5 160 3.0 3.0. 3:0 31-0 3,0 3.0 3.0 3.0 3.0 3.0 a. The table above ONLY includes 13-52 rail capacity check.It does not include roof capacity check b. Wind importance factor per ASCE7-05 C. Topographic factor,kzt is 1.0 d. Maximum mean roof height is 30 ft. e. Average parapet height is 0 ft f. Roof pitch is between 7 degree and 27 degree g. Maximum solar panel weight is 60lbs h. Height of solar panel is between 2"and 10"to roof i. Deflection criteria of L/60 per AC428 Section 4.3 j. The wind speeds above are ASD values k. Mounting Systems,Inc.strongly recommends a maximum span of 8 feet,but in any case,not to exceed the maximum span indicated on the chart I. The span length applies to a seismic design category E or less M. Maximum cantilever is L/3 13/52 Rail Zone 2 Span Chart Exposure Wind Ground Snow Load Speed 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 85 8.5 8.0 7.0 6.0 5.5 5.0 4.5 4.0 4.0 3.5 100 7.5 7.5 7.0 6.0 5.5 5.0 4.5 4.0 4.0 3.5 110 7.0 7.0 6.5 6.0 5.5 5.0 4.5 4.0 4.0 3.5 Category 120 6.5 6.5 6.5 5.5 5.0 5.0 4.5 4.0 4.0 3.5 6 130 6.0 6.0 6.0 5.5 5.0 4.5 4.5 4.0 4.0 3.5 140 5.5 5.5 5.5 5.5 5.0 4.5 4.5 4.0 4.0 3.5 150 5.0 5.0 5.0 5.0 5.0 4.5 4.5 4.0 4.0 3.5 160 5.0 5.0 5.0 5.0 5.0 4.5 4.5 4.0 4.0 3.5 Exposure Wind Ground Snow Load Speed 0 psf 10 psf 20 psf 30 psf 40 psf SO psf 60 psf 70 psf 80 psf 90 psf Exposure Wind Ground Snow Load Speed 0 psf 10 Vsf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 85 _ 6.5 6.5 6.5 6.0 3.5 5.0 4.5 4.0 4.0: 3.5 '100 6.0 _ 6,0 w 6,0 5.5- 5.0 4.5 4.5 4.0 4.0 3.5 110` 5.5 5.5 5.5. 5:5 5.0 4.5 43 4.0 4.0 3.5 Category 120 ' 5:0 5.0 5.0 : 5.0 50 4.5 4.5 4.0 4.0 : 3.5 D X30_-. �,5.0 _.5.0 5.0- 5:0 5.0 4.5 4.5 : 4.0 4.0 : 3.5 140_, 4.5 4.5 4:5 4.5 4.5 4.5 4.5 4.0 4.0": 3.5 150 4.b 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.5 lia 4.0 4.0 4.0.- 4.0 _ 4:0 4.0 4.0 4.0 4.0 15 a. Th e table above ONLY includes 13-52 rail capacity check.It does not include roof capacity check b. Wind importance factor per ASCE7-05 C. Topographic factor,kzt is 1.0 d. Maximum mean roof height is 30 ft. e. Average parapet height is 0 ft f. Roof pitch is between 7 degree and 27 degree g. Maximum solar panel weight is 60lbs h. Height of solar panel is between 2"and 10"to roof i. Deflection criteria of L/60 per AC428 Section 4.3 j. The wind speeds above are ASD values k. Mounting Systems,Inc.strongly recommends a maximum span of 8 feet,but in any case,not to exceed the maximum span indicated on the chart 1. The span length applies to a seismic design category E or less M. Maximum cantilever is L/3 13/52 Rai!Zone 1 Span Chart Exposure Wind Ground Snow Load Speed 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 85 10.0 8.5 7.0 6.0 5.5 5.0 4.5 4.0 4.0 3.5 100 10.0 8.5 7.0 6.0 5.5 5.0 4.5 4.0 4.0 3.5 110 9.5 8.5 7.0 6.0 5.5 5.0 4.5 4.0 4.0 3.5 Category 120 9.0 8.5 7.0 6.0 5.5 5.0 4.5 4.0 4.0 3.5 B 130 8.0 8.0 7.0 6.0 5.5 5.0 4.5 4.0 4.0 3.5 140 7.5 7.5 6.5 6.0 5.5 5.0 4.5 4.0 4.0 3.5 150 7.0 7.0 6.5 6.0 5.5 5.0 4.5 4.0 4.0 3.5 160 7.0 7.0 6.5 6.0 5.5 5.0 4.5 4.0 4.0 3.5 Exposure Wind Ground Snow Load Speed 0 psf 10 psf 20 sf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf Exposure Wind Ground Snow Load Speed 0 psf F10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 85 9.0 8.5 7.0 EY 5.5 5.0 4.5 4.0 ; 4.0 3.5 100 _ 8.5 8.0 7.0: 6.0 5.5 5.0 4.5 4.0 4.0 3.5 110 7.5 7.5 7.10 6.0 5,5. .�50 4.5. 4.0:_.._ 4.0., 3.5 Category 120 7.0 7.0 6.5 6.0 5.5 5.0 4.5 4.0 4.0 _3.5 0 130 6.5 6.5 6.5 6,0 S.5 5.0 A.S 4.6 4.0 3.5 140 6.0 6.0 6.O a 5:5 5.0_ 45. 4,5 .',. 4.0 40' 3:5 150 5.5 5.5 5.5; 5.5 1 5.0 4.5 4.5 4.0; 4.0 3.5 160 5.5 _. 5.5_ 5.5 j 5.0 4.5- _45. 4.0 9.0. 3.5 _.. a. The table above ONLY includes 13-52 rail capacity check.It does not include roof capacity check b. Wind importance factor perASCE7-O5 C. Topographic factor,kzt is 1.0 d. Maximum mean roof height is 30 ft. e. Average parapet height is 0 ft f. Roof pitch is between 7 degree and 27 degree g. Maximum solar panel weight is 60 Ibs h. Height of solar panel is between 2"and 10"to roof i. Deflection criteria of L/60 per AC428 Section 4.3 j. The wind speeds above are ASD values k. Mounting Systems,Inc.strongly recommends a maximum span of 8 feet,but in any case,not to exceed the maximum span indicated on the chart I. The span length applies to a seismic design category E or less M. Maximum cantilever is L/3 I�C STRUCTURAL ENGINEERS July 21,2014 Mounting Systems, Inc. 820 Riverside Pkwy Sacramento, California 95606 TEL: (855) 731-9996 FAX: (916)287-2269 Attn.: Mounting Systems, Inc. -Engineering Department Re: Engineering Certification for the Mounting Systems, Inc. 13/52 Rail Alpha+System PZSE, Inc.-Structural Engineers has reviewed Mounting Systems, Inc.'s 13/52 rail span charts, rail allowable uplift wind force and performed rail component capacity check including L foot bracket, end clamp and mid- clamp.All information,data and analysis contained within the Mounting Systems, Inc. rail span charts are based on, and comply with Mounting Systems, Inc.'s Alpha Engineering and Technical Data and the following codes: 1. Minimum Design Loads for Buildings and other Structures,ASCE/SEI 7-05 2. 2009 International Building Code,by International Code Council, Inc. 3. 2005 Aluminum Design Manual,by The Aluminum Association 4. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic(PV)Panels, November 1,2012 by ICC-ES This letter certifies that the loading criteria and design basis for the Mounting Systems, Inc. 13/52 rail span charts,rail allowable uplift wind force table and rail components capacity check are in compliance with the above document and codes. If you have any questions on the above,do not hesitate to call. Sincerely, qH OF* SiQq PAUL K. ZACHER O RUCTURAL Paul Zacher, SE -President o No.50100 GISTE SSlONAL EKF 6/30/2016 8150 Sierra College Boulevard,Suite 150 • Roseville,CA 95661 • 916.961.3960 P • 916.961.3965 • www.pzse.com CABLING ACCESSORIES - DETAILS and SPECIFICATIONS Cable Types Voltage Connector Spacing Accommodates PV module orientation 240VAC,4 conductors 1.025 meter(40") Portrait 240VAC,4 conductors 1.7 meter(67") Landscape 208VAC,5 conductors 1.025 meter(40") Portrait 208VAC,5 conductors 1.7 meter(67") Landscape Cable Specifications Cable Length Options* Description Rating Model Number Orientation #Connectors Approx weight Cable temperature rating 90°C(194°F)wet/dry ET10-240-40 Portrait 40 40 Ibs Cable insulator rating THWN-2 ET17-240-40 Landscape 40 45 Ibs UV exposure rating UL 746 C,F1 ET10-208-30 Portrait 30 30 Ibs Conductor gauge 12AWG ET17-208-30 Landscape 30 35 Ibs Compliance UL1741;CAN/CSA C22.2 { Nos 0,21,42, 65, 153, *additional lengths available through Fnphase.authorized 182.1,182.2,and 182.3;IEC distributors. 60529 IP67 ' Engage Accessories Branch Terminator I Disconnect tool i One terminator needed per branch circuit Plan to use at least one per installation 3 ET-TERM-10(quantity 10) ET-DISC-05(quantity 5) I t i i i Watertight sealing cap Cable clip One needed to cover each unused Many needed to fasten cabling to the connector on the cabling. racking or to secure looped cabling. ET-SEAL-10(quantity 10) ET-CLIP-100(quantity 100) f i i i i 142-00013 Rev 01 Enphase Energy, Inc. 201 1 st Street Petaluma,CA 94952 Phone:877-797-4743 Fax:707-763-0784 info«eno,asecnergy.con- htlpllwwmerphase con, ENGAGE CABLE & ACCESSORIES [e] enphase The Engage Cable is a continuous length NGAGE of 12AWG cable with pre-installed IES Y S T E M connectors for Enphase Microinverters to plug into. The cable is handled -Quick installation like standard outdoor-rated electrical FAST _Large branch capacity wire, allowing it to be cut, spliced and extended as needed. r -Simple design FLEXIBLE L _No additional cables The Engage Accessories complement the Engage Cable and give it the ability to r No high voltage DC adapt to any installation. SAFE L _Reduced fire risk C US criphase corn 4/29!2014 Groundng-Erjkme Energy enphase F N F R G Y Understanding Microinverter Grounding Now,with Enphase's Integrated Ground(IG)technology, fully-compliant system and equipment grounding is incorporated into the microinverter cabling and the microinverter itself; making safety and code compliance easier than ever. Isolated DC Circuit Enables Integrated Ground System Grounding vs.Equipment Grounding To fully understand PV system grounding, it is essential to Est differentiate between system grounding and equipment grounding. System grounding requires a Grounding Electrode Conductor(GEC),which connects the current-carrying circuit to ground, including: • the negative or positive of a DC array • the neutral of a split single-phase AC system • the neutral of a bi polar DC system Equipment grounding requires an Equipment Grounding Conductor(EGC), also known as bonding,which connects all non-current carrying metal parts to ground, including: • metal enclosures • racking • module frames With Enphase Microinverters,the EGC is bundled into the Engage Cable wiring system,which forms a ground connection with the enclosure of the microinverter. Plus,Enphase Microinverters with Integrated Ground do not require a GEC because the unit physically isolates the DC circuit within the microinverter from ground,thus meeting the NEC requirements for Ungrounded Photovoltaic Power Systems described under section 690.35. http://enphase.caMgrounding/ 1/3 Enphase Microinverters&Ungrounded PV Arrays Fully Integrated Microinverter System Ground Like the Enphase M190 and the previous-generation M215,the Enphase Microinverters with Integrated Ground are utility-interactive microinverters.All Enphase Microinverters use transformer coupling to isolate the DC and AC circuits.The major difference between the grounded and integrated ground models lies within the DC input stage of the microinverter,where DC power from the module enters the microinverter.Enphase Microinverters with Integrated Ground do not ground the DC input,as did their predecessors.By isolating the DC conductors from ground,Enphase Microinverters with Integrated Ground enable the installer to create an NEC-compliant Ungrounded PV Power System(690.35,690.41). With the Enphase Microinverters with Integrated Ground,the grounding requirement is satisfied with an EGC,so a GEC is not required.The EGC Is provided through the Engage Cable system that has been certified and listed for this application. Linet Line2 Neutral ac EGC +[X AC GPDI Invert IM -DC Enphase Microinverters with Integrated Ground: Ground Connections In previous models, the DC input was bonded to ground through a GFDI circuit.This essentially grounded the PV module's output This construction required connection from this point to the grounding electrode using a GEC.However,since Enphase Microinverters with Integrated Ground isolate the DC conductors from ground,only a simpler EGC is required.The EGC is provided within the Engage Cable system, which connects seamlessly to the AC power system output of the microinverter. Enphase Microinverters with Integrated Ground detect ground faults in either the DC positive or negative conductor of the PV module by detecting the insulation resistance of each conductor to ground.Also new to Enphase Microinverters with Integrated Ground is the Insulation Monitor(IM),which measures the insulation resistance of the DC circuit with respect to ground.Together,these features offer greater safety than previously possible in any inverter technology. Acronyms and Definitions AC Alternating Current DC Direct Current EGC Equipment Grounding Conductor Engage Cable Enphase cable system listed for use with Enphase products GEC Grounding Electrode Conductor GFDI Ground Fault Detection and Interruption IM Insulation Monitor NEC National Electrical Code PV Photovoltaic WEEB Washer,Electrical Equipment Bonding 4 ®2014 Enphase Energy Inc.All rights reserved January 2014 Enphase Microinverters&Ungrounded PV Arrays Building Arrays with Grounding in Mind Many methods are available for installing PV systems that enable a variety of approaches both to system design and to system grounding.We discuss two common methods and place emphasis on specific grounding requirements. • Mire EGC: The PV modules are mounted to the racking platform with mechanical clamps and clips.As per NEC 690.43,all exposed metal must be grounded.An EGC provides a conductive path for the racking and PV module frames.The EGC is connected to each PV module frame and all racking members.The EGC from the array can be connected to the AC EGC that then connects to the AC ground system. Main Panel Board Ground Bond Equipment Jumper(GBJ) Ground Conductor Neutral Neutral Bar Ground (EGC) Electrode Ground b Conductor Bonding Point Ground Bar (GEC) AC EGC Ground _ Electrode I r Enphase Microinverters with Integrated Ground with EGC Connecting PV Frames and Racking • WEEBs:WEEB equipment bonding washers can be used to connect the PV modules to each other or to the racking for the purpose of equipment grounding.NEC 690.43 and 250.136(A) allow for the equipment to be electrically connected to mounting structures that are themselves grounded,and the electrical connection bonds the equipment frame to ground.To be considered grounded,the mounting structure must be connected to an equipment-grounding conductor. WEEBs can only be used as part of the EGC system. Main Panel Board Equipment Ground Ground Bond WEEB Conductor Jumper(GBJ) Bond (EGC) Jumper Neutral Bat( Ground Neutral Electrode Ground Conductor Bonding Point Ground Bar (GEC) AC EGC Ground Electrode Enphase Microinverters with Integrated Ground with WEER Ground Jumpers 3 0 2014 Enphase Energy Inc.All rights reserved. January 2014 Enphase Microinverters&Ungrounded PV Arrays PV Grounding Terms Under NEC definitions in Article 100,two conductor types provide paths to ground.These are the Equipment Grounding Conductor(EGC)and the Grounding Electrode Conductor(GEC).Distinguishing between the EGC and the GEC Is important when ensuring a photovoltaic array is code-compliant and safe.The following describes key terms from the NEC related to PV system grounding relevant to Enphase Microinverters. For reference,grounding requirements for microinverters are covered in UL1741 while grounding requirements for photovoltaic systems are covered in the NEC under Article 250 with amendments in Article 690.Always check with your jurisdiction for information about local amendments to the code. Underwriters Laboratory(UL)Standard 1741 grounding requirement: In Spring 2012,UL issued a document amending UL 1741 to address inverters for connection to ungrounded PV arrays. Enphase Microinverters with Integrated Ground have been successfully evaluated against this document.Therefore,a grounding electrode terminal for the attachment of a GEC is not required for this microinverter.All required grounding for Enphase Microinverters with Integrated Ground is met by the AC EGC supplied by the Engage Cable system and meets both NEC and UL requirements. National Electric Code grounding definitions: The Grounding Electrode System: Described more fully in NEC Article 250 Part III,the grounding electrode system provides a network of conductors,bus bars and bonding within a facility through which a direct connection to earth is established.The grounding electrode system is comprised of the equipment ground conductor,the grounded conductor,the grounding electrode conductor,and the grounding electrode. Grounding Electrode:Is a conducting object through which a direct connection to earth is established per the requirement outlined in NEC 250.52.Typical examples of a grounding electrode are a ground rod,buried metal pipe, plate electrode,concrete encased ground(UFER), and/or a ground ring. Equipment Grounding Conductor(EGC):Provides a conductive path to connect normally non- current-carrying metal parts of equipment together.EGCs are also found in traditional household wiring and connected to the rounded contact in a three-hole,grounded wall socket.The EGC is also used in the PV industry to connect all exposed metal parts such as PV module frame, racking structure,wiring enclosure(combiner and junction boxes),and the microinverter chassis. With Enphase Microinverters with Integrated Ground,the EGC is supplied through the Engage Cable system. Grounded Conductor:The NEC defines the grounded conductor as a current-carrying conductor that is intentionally grounded. Examples are the Neutral conductor found in an AC system or a grounded DC conductor found in many PV systems.The point at which the current- carrying conductor is connected to ground must be connected to the grounding electrode with a GEC. Grounding Electrode Conductor(GEC):The purpose of the GEC is to provide a conductive path to connect the common grounding point of the power system(AC or PV power systems)to the grounding electrode or to a grounding electrode system.AC or PV power system grounding is established when a current-carrying conductor is intentionally connected to ground by a GEC. 2 0 2014 Enphase Energy Inc.All rights reserved. January 2014 WHITE PAPER [e] enphase Enphase Microinverters and Ungrounded PV Arrays Enphase M250 and new M215 with Integrated Ground—no need for a separate GEC Overview Enphase has developed a new microinverter family that includes the M250 and new M215 with integrated (DC isolated)ground.Because the DC circuit is isolated and insulated from ground,these microinverters do not require a Grounding Electrode Conductor(GEC)connected between each microinverter.The Enphase Microinverters with Integrated Ground are compatible with most 60-cell PV modules(210W to 30OW STC or higher)and install quickly and easily.They work with either three-phase 208 VAC or single- phase 240 VAC services.Enphase Microinverters ship with integrated DC and AC cables and connectors.The DC connectors attach to the PV module,while the AC connector attaches to the EngageTM Cable. No additional cabling is needed. An ungrounded array,when coupled with sophisticated features of the Enphase Microlnverters with Integrated Ground,offers greater safety for the installer,system owner,and maintenance personnel. In addition to enhancing safety,the Integrated ground technology streamlines,simplifies,and economizes the installation process for installers and inspectors of all project types. This document clarifies solar grounding terminology and describes NEC(National Electrical Code) compliant grounding methods for Enphasee Microinverters with integrated(DC isolated)ground.The 2008,2011 and 2014 editions of the NEC allow for ungrounded PV arrays based on the provisions specified in NEC article 690.35. Features • Integrated ground eliminates the need for a GEC:Enphase Microinverters with Integrated Ground isolate the DC conductors from ground.This has the significant advantage of eliminating the need for a GEC connection between microinverters. • Ground fault detection on board: Enphase Microinverters with Integrated Ground offer advanced features to detect DC ground faults on either DC positive or negative conductors and always check the insulation resistance before exporting power.This eliminates the hidden ground faults that often go undetected with less mature microinverter technologies. • Smart disconnects:As on all Enphase Microinverters,the AC and DC connectors are rated and listed as disconnect devices under load per the NEC requirements.This simplifies design and eliminates the need for redundant and hard-to-locate disconnect devices. • Ruggedized DC wiring: Each Enphase Microinverter with Integrated Ground is built with PV (Photovoltaic)Wire for all DC conductors.This provides double insulation for protection against wire damage and meets all wiring requirements of NEC 690.35.The PV module must also use PV Wire. 0 2014 Enphase Energy Inc.All rights reserved. January 2014 TECHNICAL BRIEF [e] enphase Enphase Microinverters with Integrated Ground (IG) Enphase's latest generation microinverters feature Integrated(DC isolated)Ground. Because the DC circuit is isolated and insulated from ground,these microinverters do not require a Grounding Electrode Conductor(GEC)connected between each microinverter.This means you don't need to attach a separate copper grounding conductor to each microinverter or worry about a continuous run to ground. The result is faster installation with lower materials costs and a safer system. Integrated Ground and Code Requirements Solar installers must comply with the National Electrical Code(NEC)when installing Enphase Microinverters. Enphase Microinverters with Integrated Ground meet the requirements specified for Ungrounded PV Power Systems in sections 690.35 and 690.41 of the 2008,2011 and 2014 NEC. It also meets the Underwriters Laboratory(UL)Standard 1741 grounding requirements. For further information,refer to the whitepaper on Enphase Microinverters and Ungrounded PV Arrays and other materials at www.enphase.comlGroundina. Identifying Microinverters > Wgrouncmg *rininal with Integrated Ground Installers and inspectors can easily FlatBd Identify Enphase Microinverters with Integrated Ground. Installing Microinverters Productl'abet with Integrated Ground °f;e"°"' Enphase Microinverters ship with DC and AC cables and connectors.The DC connectors attach to the PV module,while the AC connector attaches directly to the Engage— Cable. It's that simple:no additional cabling is needed. About System Grounding Electrical code requires two types of grounding conductors.the Grounding Electrode Conductor(GEC), which is used between the grounding electrode and the point where a normally current carrying conductor is intentionally bonded to ground and the Equipment Grounding Conductor(EGC),which grounds non- current carrying metal parts of the system,such as the racking and module frames, Because Enphase Microinverters with Integrated Ground have DC integrated ground,they do not require a GEC. However electrical code still requires that exposed metal in the array be grounded(NEC 690.43 and 250.136(A)).This requirement is met for the microinverter because the ground conductor internal to the Engage Cable acts as the EGC. It may be met for racking and modules with use of an EGC or WEEBs to provide bonding to this ground system. 0 2014 Enphase Energy Inc. All rights reserved. January 2014 Enphase,I M215 Microinverter//DATA INPUT DATA(DC) M215-60-2LL-S22-IG/S23-IG/S24-IG Recommended input power(STC) 190-270 W Maximum input DC voltage 48V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22 V/48 V Max DC short circuit current 15 A Max input current 10A OUTPUT DATA(AC) 0208 VAC 0240 VAC Peak output power 225 W 225 W Rated(continuous)output power 215 W 215 W Nominal output current 1.1 A(A rms at nominal duration) 0.9 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range' 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 25(three phase) 17(single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency,240 VAC 96.5% CEC weighted efficiency,208 VAC 96.5% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted,reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA ..... Ambient temperature range -40°C to+65°C Dimensions(WxHxD) 163 mm x 173 mm x 25 mm(without mounting bracket) Weight 1.6 kg(3.4 Ibs) Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 FEATURES Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35.Equipment ground is provided in the Engage Cable.No additional GEC or ground is required.Ground fault protection(GFP)is integrated into the microinverter. Monitoring Enlighten Manager and MyEnlighten monitoring options Compliance UL1741/IEEE1547,FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, ( � enphase° visit enphase.com L t N F h c v ©2014 Enphase Energy.All rights reserved All trademarks or brands in this document are registered by their respective owner Enphase®Microinverters Enphase,, M215 ............... The Enphase' M215 Microinverter with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor(GEC) is required for the microinverter.This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M215 integrates seamlessly with the Engage®Cable, the Envoy®Communications Gateway", and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE RELIABLE Maximizes energy production No GEC needed for microinverter More than 1 million hours of testing Minimizes impact of shading, No DC design or string calculation and millions of units shipped dust, and debris required Industry-leading warranty, up to 25 No single point of system failure Easy installation with Engage years Cable Jenphase® �Ay E N E R G Y G US NEC 2014—Enphase System Code Compliance NEC 2014 Section 705.12 Point of Connection Code Reference 705.12(D)(6)Wire Harness and Exposed Cable Arc-Fault Protection.A utility-interactive inverter(s)that has a wire harness or cable output circuit rated 240 V, 30 amperes,or less,that is not installed within an enclosed raceway, shall be provided with listed ac AFCI protection. This requires exposed AC cable systems, such as the Enphase Engage Cable,to be protected by AC Arc-Fault Circuit Interrupter(AC AFCI)protection devices in the AC panel. Since Enphase Microinverters are utility-interactive inverters that backfeed into the electrical service through the overcurrent protection device,any overcurrent protection devices with AC AFCI that are installed must be specifically backfeed capable. NEC 2014 705.12(D)(4)Suitable for Backfeed.Circuit breakers, if backfed,shall be suitable for such operation. If terminals of circuit-breaker AFCls are marked"Line"and"Load,"then the product is not backfeed capable. Today there are no known AC AFCI backfeed capable products in existence or planned, so Section 90.4 of the NEC code advises the inspector/AHJ to grant permission to use products that comply with the most recent previous edition of the Code. Until AC AFCI backfeed capable product is available,complying with NEC 2014 Section 705.12(D)(6)is achieved by discretionary guidance per NEC 2014 Section 90.4 and referring to NEC 2011 Section 705.12,where AC Arc-Fault Circuit Protection is not a requirement for utility-interactive inverters. Code Reference 90.4 Enforcement. This Code may reauire new products, constructions, or materials that may not vet be available at the time the Code is adopted. In such event,the authority having iurisdiction may permit the use of the products, constructions, or materials that comply with the most recent previous edition of this Code adopted by the jurisdiction. NEC 2014 Section 690.11 DC Arc-Fault Circuit Protection This requirement is for direct current(DC)Arc-Fault Circuit protection, and only applies to systems with DC voltages above 80 VDC. Enphase Microinverter systems are exempted from this requirement as they always operate well below 80 VDC.The requirement is basically unchanged from the NEC 2011,and it is unnecessary to add DC AFCI to an Enphase Microinverter System installation. Code Reference 690.11 Arc-Fault Circuit Protection(Direct Current).Photovoltaic systems with do source circuits,do output circuits,or both,operating at a PV system maximum system voltage of 80 volts or greater, shall be protected by a listed (dc)arc-fault circuit interrupter, PV type,or other system components listed to provide equivalent protection. 2 0 2014 Enphase Energy Inc.All rights reserved. March 2014 TECHNICAL BRIEF [ei enphase NEC 2014 — Enphase System Code Compliance Overview This technical brief discusses new NEC 2014 requirements that apply to Enphase Microinverter Systems. It is useful for installers,electricians,and electrical inspectors or authorities having jurisdiction(AHJs)for understanding how code-compliance is handled where NEC 2014 is adopted. Main topics discussed in this document are: • NEC 2014 Section 690.12 Rapid Shutdown of PV Systems on Buildings • NEC 2014 Section 705.12 Point of Connection • NEC 2014 Section 690.11 DC Arc-Fault Circuit Protection NEC 2014 Section 690.12 Rapid Shutdown of PV Systems on Buildings Enphase Microinverter Systems fully meet this rapid shutdown requirement,without the need to install additional electrical equipment. Properly labeling the PV system power source and rapid shutdown ability is required per NEC Section 690.56(B)and(C). Solar electric PV systems with Enphase Microinverters have one utility-interactive inverter directly underneath each solar module,converting low voltage DC to utility grid-compliant AC.When the utility grid is available and the sun is shining,each microinverter verifies that the utility grid is operating within the IEEE 1547 requirements.Only then does it export AC power into the electric service for use by loads onsite or export power to the utility grid for others to use. When the utility grid has a failure,or the PV system AC circuits are disconnected from the utility service via an AC breaker,AC disconnect or removal of the solar or main utility service meter,the microinverters stop producing AC power in fewer than six AC cycles. Enphase Microinverters are not capable of operating as an AC voltage source.This means that without an AC utility source, Enphase Microinverters are not able to energize connected wiring and no AC voltage or current can be injected into the PV system AC circuits or the grid. When the AC utility source is removed from the PV system AC circuits via any means, such as an AC breaker,AC disconnect, or removal of the solar or main utility service meter,this equipment performs the rapid shutdown function per 690.12. With an Enphase Microinverter System this shutdown occurs well within the 690.12 required 10 seconds,and there are no other conductors energized more than 1.5 m (5 ft)in length inside a building or more than 3 m(10 ft)from a PV array. Code Reference 690.12 Rapid Shutdown of PV Systems on Buildings. PV system circuits installed on or in buildings shall include a rapid shutdown function that controls specific conductors in accordance with 690.12(1)through (5)as follows. (1)Requirements for controlled conductors shall apply only to PV system conductors of more than 1.5 m(5 ft)in length inside a building,or more than 3 m(10 ft)from a PV array. (2)Controlled conductors shall be limited to not more than 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. (3)Voltage and power shall be measured between any two conductors and between any conductor and ground. (4)The rapid shutdown initiation methods shall be labeled in accordance with 690.56(B). (5)Equipment that performs the rapid shutdown shall be listed and identified. 1 ©2014 Enphase Energy Inc.All rights reserved March 2014 To learn more about the Enphase Microinverter System, visit enphase.com [e] enphase® E N E R G Y Enphase Energy If Microinverter Product Family M250 vs. M215: Module Pairing Considerations There are instances where either the M250 or the M215 is an appropriate choice for pairing with a given module. For higher power 60-cell modules,the M250 is the logical choice. For lower rated modules, select the M215. However,for modules with STC output ratings between 25OW and 270W, there are several factors to weigh when deciding which microinverter to select for the application. MODULE E .• R RANGE SNOW 2M 0 etursen 2EOW and 27OW Above 27M SELECTION MICROINVERTER M215 Installer prebmice M250 Factors to consider when pairing Local tempeaWro3skes advantage of these gams cooler climates.result In higher module output and selecting the M250 with 25OW—270W modules Module queft and performance:not all modes we created equal.Even modules from ditferent brands with the same mmeplsts raft can often vary widely in actual DC output, given variance in manufacturing and quality assurance testing standards.Keep module quality In mind when assessing expected output. Perspective On clipping:depending on the module brand selected and the installation location,an M215 can cip when paired with a module with an output rating above 250W. Depending on the installer's calculations of the system's financial performance,such dipping loss can be either Inconsequential or signMcant when Installing modules In the 25OW—27OW output range. A note about WAS Starting in January 2014,Enphase will furnish the new M215 as a replecernent unit for authorized merchandise returns received for the previous M215.Note that the new M215 unit does not require a GEC.Contact Enphass.comisupport for assistance regarding returns. To learn more about the Enphase Microinverter System, visit enphase.com [e] ephasee E N E R G Y Enphase Energy/Microinverter Product Family Enphase Microinverter Family: Similarities and Differences Enphase is pleased to offer a What's changed What's the same new M215 Microinverter based The new family feature: Product quality:rigorous design, y of products manufacturing,and test standards on our fourthgeneration .. Hlghorof lency:98.5%CEC da(uradustry-In industry-leading standards Integraed Ground 00):Both the now platform. In early 2014,the new 25-year warrunty:exbemsly low failure. M215 and the M250 teahae IG rates enable industry-leading tinged M215 will replace the old M215 technology,do not require a Grounding warranty to complete a microinverter Electrode Conductor(GEC),and meet • F�simple installation:plug-and-play product family that features high National Electrical code Zoos; Engage Cable system enables rapid, P Y g requirements for ungrounded PV Power flexible installs efficiency,easy installation, and Systems(Sections 890.35 and 690.41) Durability:rugged,NEMA 6 rated industry-leading reliability for Meets or exceeds 2014 NEC(690.12) • enclosure pairing with any 60cell module FFooruRapid s utdown of PV Systems on on the market. Buildings Now look:Flat lid without a grounding lug,for easy identification FEATURE PREVIOUS M215 NEW M216 M25D Integrated Ground? No Yes Yes Lid type? Grooved for GEC Flat Flat' Ground symbol etched on lid? Yes No No Recommended input power(STC) 190-270W 190-27M 210-30M CEC weighted 96.0% 96.6% ----- 96.S% — efficiency(240VAC) Peak output power 225 W 225 W 250 W Maximum units per 20A branch circuit 17/25 17125 16124 (240 VAC/208 VAC) M215-80-21-L-S221S23 M215--� Part number 60-2LL-S22-NA/S23-NA(Ontario) M216-60-2LL-IG-82218231524 M250-60-2LL422/S23IS24 215 Watt Utility-Interactive Inverter Unit label text with Integrated GFDI M215 Utility-Interactive Inverter M250 Utility-Interactive Inverter *For M250s manufactured post-January 2014. i I I I I Cti Id mnkc IfIinLs and recordings%,itII n?,�fiutGoriurs as roati be lnlure vt die Svs[em.or tle.Sti.tem iustallnuon. BF.MADE BY YOU AGAINST US OR ANY arty :upce:t,,I the rclau,mdtilt hr ne Cell N ou.uul i , ve hail,t hand i n amtnict,h i l t-,tarok or any ,a l e t l e-L'a l six l�.f i l l tilt,Aerc emcnl III aus odtct ai_�reenwnt 'oneer7111W the ,uhlccl mantel hetcol`, 11111 an} launch dci:utlt. ut lernlinau,,u rot tht Nvrc�e�ntcnl. atul (ik)[tic intcr III"IM lot. e tlitlii of cnIol e,lhlhlc "I'tht A a'Clntem.tnrhr1111"the dcicrnunati,nt w the he nt ,yt(tlica)eitit� of tilt S�ehun teach,a Puna to uumnutcirm,11'htiraunn a parse inu,i lint,cnrl a cu tnln"Stttiec„f I>i,put. con ertilied n itil to tilt c+thcr tnrtb the \ottte"i DtsIn111 Hula d1,elihc lit, naunc end ha,t, till they Dolton and th_c rchcl ,u and\1'�arc uttahlc to t ,ohc 1110 151,putc thin Burn 1++ti da}:_ then enher ]torte ton smtntencc' a111ivauon the arbt)tauon ,hall he adnunntrrcd ht I\\IS pursu ant to it, Strcan11n11d lrhtuunnn Rulr,mul I'u,cctlut arrrhtt�lr,it httt ee,ow (am,adl ,,III w1cti ircantlnied athttrall I.the 'J11IN Xrtfes'").+ud undet the ndc,'Cl brill ut tilt,.Ngucittcnt, hhc all-intatol ,hail�t1 hc,und h- the lei-III,of tilt. kerecmrnt No ntanc�t till circuntstanres,till arbitrator hall not.Heald Iaunntec ,x,1,11, escmpiaty uuhrcct ur con,equl111131 IIAI acs t other hart If Nnu ioihalc Jrt1lIrnnon_ YOU ,hall he rc,ponsihtc to(tat ,2'0 \�I attorrnti, le°1s. 11,1c11 1,l,ut 1,. and ,dhcr ,t,„t th° art,itrati ai~11.111 he' horns ht N cnt and t s ht ac cord:ene'c ceith tilt 1.1\iS I.nic,,ltd a)plicah1l Id%v I hr arhitr lion shall be ennducted at a n'�u1ua11V t tCrahle 4aauon near N'our Properh IUd@ntlnt nu gut arhiirttion aecaui may��e Clod-1d in.un iourt,�I:untpewnt)un,dietio,. Notltnt in(lit tick li{,n 7,hall prechule Yttu ar A4r I'nnii let itt�,prt,t t,n,n;ti tenirdtc,m aid Ot'11 (rant a court of :,anpcicni lun,dt,:n,-v NOTICE: BY INITIALING IN THE SPACE BELOW YOU ARE AGRF_LING 10 HA\F VAN DISPI 11. ARISIN(:01 01'1411: 1; MATTERS INCLUDED IN THE"ARBITRATION OF DISPUTES" PRO\ISION Dl(IDED FIN NI,'t I RAE `,RBI LRA I ION AS I, PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING: 1 P ANN RIGHTS N Ot y11(,111 POSSESS FO HAv F I'IIF DISPUTE LITIGATED IN A COURT OR JURY TRIAL BY 1\II I:Alx'(. IN Itil SP\('F Bt`LO\N N 01 ARE ( I\I\C: CP I; YOUR JUDICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOt REF USE: fO St'BAtI I TO ARM FR AI ION A1"1 Fit AGREEING TO THIS PROVISION, YOU MAY BE COMPEl1.lU) 10 ARBEIR\FF. YOlt R N('REI�\IFNI TO THIS ARBITRATION PROVISION IS VOLUNTARY. YOU HAVE RJ, AD \ND t NDF.Rtil \\D I IlF FORF(OI\(: AND AGREE TO SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCl_l DED IN 1 ITh"%RBI I R,A t ION 01 DISI'111,S" PROVISION TO NEUTRAL ARBITRATION. Customer(s)Initials: I/WE AGREE TO ARBITRATION AND WAIVE THE RIGHT TO A JURY TRIAL: 6.NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT: (i)this Agreement,(ii)the Additional Terms and Conditions,(iii)the Customer Packet,and(iv)the Work Order. These documents are expressly incorporated into this Agreement and apply to the relationship between You and Gs B. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY"BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALL OF ITS PAGES. You acknowledge that You have read and received a legible copy of this Agreement,that We have signed the Agreement,and that You have read and received a legible copy of every document that We have signed during the negotiation. D. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by both You and Us,before any work may be started. E. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO THE LATER OF: (1)MIDNIGHT OF TILE THIRD (3RD)BUSINESS DAY AFTER THE TRANSACTION DATE,OR(11)THE START OF INSTALLATION OF THE SYSTEM. SEE THE NOTICE OF CANCELLATION BELOW FOR AN EXPLANATION OF THIS RIGHT. VIVINT SOLAR DEVEI.1PER,LLC CUSTOMER(S): - T , e , Printed Name- } Printed Name: ��e ?-_ q, a '` q>•.�i,,n�_fi�� n� , r' I tlic �7ff-[Lt1��'a`J- l t eprinted By: Name: Transaction Date: ►cj �� FOR INFORMATION ABOUT CONTRACTOR REGISTRATION REQUIREMENTS, CONTACT THE MASSACHUSETTS OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATION:TEN PARK PLAZA,SUITE 5170,BOSTON,MA 02116, (617)973-8700 OR 888-283-3757. NOTICE OF CANCELLA'T'ION Transaction Date: AR No.: N OF \1 N) ( \\( F'.1. I FITS I R V\SA('110N, AN 11110t T :A\N PF N A I I N OR OBL,I(.,t I10N. AN ZZIII\ IFIRI F (3) BL SINESS 1)NNs OF IHE \BOV"F DA7F, OR (IF L.AIE R) I NT11 IHF S1 \R I` OF 1\ST11.1.AIION O1 116 SNS1FNL tF NOt' (AN('FI_, ANN PRO1'F'Rll 1 RADED IN, -ANN P,1N\IF.NTS NS-ADF BN NOT' t NDER FllL(ON1 RA( 1 Olt SALE.-AAD.ANN NI?C:UII\BI F INtiIRIAII NI FXF.( I FED BN NOt A\It,1, BF: Rf 1t RNED \\1THIN TEN (10) BFSI\ESS DAIS FOI.1 ON\1\G RF( F.IP 1 B) I ill( St:I LF.R OF \Otto ( AN( 1-I.1 A I ION NOl l( F, \\I) \\N SF(°tItj IV IN LRF.S I Ai(ISING OVI OF IHF ZR\NSA( fION \111,1 BF("VNCFI.I.F.D. IF NOt ( ANCE.L. NOL All'SI NIAKF VN-A1LABLE 10 7IIF SF:LLFR A'I NOtR RFSit)E\('IC, IN St BSI-ANIIV1 I N AS GOOD CONI)[I'IOA vS A\IIFN Rt?CIi1NF;D, A\1 GOODS D11 1N ERF') I"t► N Ot tADER I ISIS CON R V I OR SAI V. OR N Of \11\\. IF TOL M ISH, (OMPLN \\lilt TH1. INtifRI('11IONS OFT IIF SFLII•_R RECARDINC THE" RF I tR\SHII,N1LN'I (►F tilf GOODS AI I IIE SF.I.t_FR'S F\1 F:NSF \ND RISK. IF N Of DO AL\KF I'HF"GOODS;AV-1411.A13I4. FO I HF SFJ I ER VNJ) I HE S A LER DOES\OT PICK 1 HEM t P N\IF ILIA T\N F\TN (211) 1)AN S 01, 1 HF" 1)A I F OF N Ot NOI E OF (AN(FI I I ION, )Ot \I AN RF"I VIN OR DISPOSE OF Fill:. GOODS N\1 I 110t,I VAN Ft 14'Fill R OBIIG A"IION. I1 N Ol F UI_ FO\t\KL 1 HI GOODS %\AIL\1111 f0 THE SF I Fit,OR 11, NOU AGREE 10 RF.II R\ THE. (:ODDS 1.0 ZHF SELLER :AA ) 11\11 ZO DO SO. II11•N NOF RENT IN 1.1\BLf FOR PLRFOR\IA\(F: OF \1-I OI3t.l(iA IIONS t NO1 R 1FH (O\IRA( 1. 10 ( \\(1;1. THIS TRA\SA(TIO\, NJ V11, OR 11F11\1Cl2 A SIG\ED :AND 1)\IF:D COPN OF "I HIS (AN(Elf%I ION NOI R F OR ANN O I HER NN'RIITE\ NO"I WE.OR SEND A IF:Itt:(-RANI, 10\IN IN T SOLAR DF:A I-I,011FR,I I(.A 1 4931 \3tlo\\.PRO\O,Fl 846114 PRIOR 10 Il1F ['AI ER OF: 111 NIII)NIG111 OF '1111, 1111121)OR") litSI\FSS DAN Al II(R I IIF I RA\S.AC'ZION 1)\TF,OR ill} FHF SI NR I OF INSI AlF.A,,ON OF liF SN S I NJ. I llf;RFBN ('\NCEL THIS TRANSACTION: )at Customer's Signature: , 3301 N-Thanksgiving Way,Ste 500.Lehi.CT 84043 Employer Identification No.: 80-0756438 vivi nt. solar .ra Phone:(877)404-4129 Fax:(801)765-5758 Massachusetts HIC License No.: 170848 E-Mail! support(tvvNimsolar.com (} t www vivinlsolar.con) AR No, C— L- RLMDEN t IAL I'ON%LR PLRCIRASL AGREENIEN i' This RESIDENTIAL POWER PURCHASE AGREEMENT(this`Agreement")is entered into by and between VIVINT SOLAR DEVELOPER,LLC,a Delaware limited liability company("We"."Us","Our")and the undersigned Customer(s)("You","Your'),as of the Transaction Date set forth below. Full Name n,,, n r , j (n�� y^�5 17 Full Name tF , nrl.cure, l v, O re, ❑ _C.�,fLY,1.1 \.1�'�C.{ V/1!,il,t VS 1' (honer ❑Y t O_zV telephone\„ J !r / t7� v I'ropert\ Snrrt \d(hr„. f^ '{ Address: City,County,State,lip 1.SERVICES A. DESIGN AND INSTALLATION. We will design,install,service and maintain a solar photovoltaic system on Your Propert which will include all ­J­panels_inverters,meters,and other components(collectively,the as as further described in the Customer Packet and the Work Order that We alit t,,.idc r+ , a hI1l: 1Wt -Ali n)ti ttii 1' a a• „±to tc'u Atit 1 e u. , tit `) t i,• d t h,,r ,c and electricians,and not subcontractors. k\,Ii, N"oin at,per.ttunr A\: I'll[ i it t. i_n_ 'n tall .uni. 11;1.ct Ill, ,.,tcm Ili nrrncn,u "' iii"n” „,III ,lit o1,f,ln ahle J;m" lit,con)plct, _ill rcynic'i ❑ijK'c Eiun>,and I'll)s,l unl.ell ic'Juncd_wfi,Jzl w,.ittU porlin, In„rdor I" I tt•I,.t I, Lent that `1 ,,It (teed, 'i o ai q,ITC 0m] %'i I:nliit"hwill It ,III "Lill leaf usa 'ht,t„t� ti m N,rta I•,I(ie rt6sit, tulle"1/hilt A to f) ,it,1),',l I'lo,tdr 1,+vlit w1,le,„1 \rnit (-bin, t,iU,,I,Abe lure, n°asnnah:•, r<,lue,( (.)lifer tha❑tiie aelit.1, 1 c lurr(1 1 u-So non, 1 li Vl , 11 d..lire,.and nl,i.i,ilie}„tnu •n,not t„A ni $. 1(11%111 ION, Ail tire,I, I,.,% i .t.,lie(IM,A t(i Li,n I” it In, is), rnr,r)" � ... A\, a Ill III,a oniieet Ili t•o lilt ill,, I lil.,t..,lilt ea i the Sv,Ivll t rm,.i de of�r , nr a,ui,d it, k11,+,uI li ur,I hit 7(l r li /:never'-1 kuaall;unm ai the w,irin _enertlty inks.„tic dal and .tntie.palcd to 1 e;m and i r,u!nt:u(i,11 cnn)plcic I e1,rre,t in,,111 and,iv I,,l,,r,k,hete,ilicr <. OV\NF`RSIIIP OF SN',I V Ai. A\r,h;it4 i„n)lit,1t,tt9l) i,t till­le poi+luau I,ny,ctlt \'I'l ill hair no 111"110I, uuere,I m Ihr tiy,ten; 1). OPFR\710151VDv111A11-NA♦CF I,\, ,,if.,{,rrs icea,tm_ilit.:_m Ili, ",'tailIii,o(hi, ,1r1-1.'u.,,I,crt,c_kill an „,>d.,a,<5sinit;and I'm w nut na1 caul/han,c+;uh (I}apph,d I i i a 111';IIW�AVI I till 1'I'It A icyuirements. F. INsVR VN(t. A\ :arrr..,nn i,t„ol�-vttc Il l,:ihilll compensation insurance,and property insurance on the System For more mlhrrnmi,at.:,+nrcnnu'r i tar In,urun;..and;, ahtain a e,q,r„1 I lit,cerlili-ne•orinsurance,please visit wifvw_vivmtsolar_comlmsurance. 2."I-ERNi,PRI(K,PAN NILNTS.AND FINANCIAL DiSCLOSL'R, A. ENERGY PRICE. For all Energy produced by the System,You shall pa Us$0. per kWh he"Energy Price'),plus a plicable taxes. The Energy'Price shalt increase each year by two and nine-tenths lxrcenl 12.9"',). A good of lull estimate of the Svstem output,measured m kilowatt hours, will be provided to You in the Customer Packet. THIS AGREEMENT 1S FOR THE SALE-OF ENERGY BY US'fO YOU AND NOT FOR THE SALE OF 1 iOt \R I'MKt-) DLCI("I R. If-k%l Thi, N�•ncmrnr,hall Ir�Clc<tnr a,�,1 Ittc ]i.nt.aru,vr I)n(..inJ:,suruc atilt/tP,c t,,,n,te(h i'u"1 aniu+,t,nn .•#the Ilr�rr ice Dute tube °Tend-i (li H(Srrrtcr Dufe' haU?x'ill sir I dal (n :II ,i sh ( ll+,r ui .,t Ik'n aehu, {. i tli< ti., ni I, I i)in,(ill ill and I e,s,,I"Ic,rl- xrncr�(un_ iii)all pernni?n,,c-11,l.,,po,ltc th, ` n,11,I,i:five,,,I iamed_i in r tha�,,t,In ha>i,c.t,+ul,rc+anteet,d r,till (Iliht,I it u,1 all in,l�eiiun,an i lie"hill/r:Hc>n•qutt'ed mulct appliad,h:I.r,r„r he Ilse 1. tilrir I i hru<,,,IIPI�Ie,I,u rc.et,cd C. 11%1 Nit".Ii1. Reauminu aiib the lirvi nnnuh 1„1' i,lnv the In rule, D,ttc and lin-01,.ut tile° Icnu.A\e "ill cm l Niiu air im""e "Ilcoine lit, 'h r ,Inr I tie , vl"d,ecd fi% Ill, s„ ICnt in ill,-fireri t nrmdt. )„u li.til i eke In n1u, ")emI n,u,I,t, tt t,an,(ne pa,nie(u c Nown Joint N our Ile,i.;.Ilcd ehu> 6,_,a,,:mul, it:,tedu „rd I!i,1 nw I. po,1,il,ih,% io e i,ln that there are a,�e.luate fLnd,Ili adutnam Breda limit Il err t,nn Imancinr eh irze a„,x rued rcith tlli,4Yrrem,aii 1 oI all pacmcni,;u„re thsn'tell t llr4,Ia,>p:ul due i1e mar nnpo”a t:t clime”e-,p+al to i aeeh-lice-Dollar, u)1 silt test at a mined I'll,,,ii tell i nrnt( Ii If (.Li, (I h abl Pt, It \ u,e,ntiuu t„tad 4„make_m, l,;n mehri „iihni tell 11+)i day.aAcr V\e pltir )',n;written n aiec_then\A,ncn osier-c all iemedic,armlal Ir I„t ,pursndnt h �ccthm I ltF_s D. RE\F.A\if A(th,, rI)d,+11h: Cent.1,ai ta.r,rL:et bi iui u,auuntc„nh a1u, A rc.mrmf,m_r- ':ti n,-,ear b.ol,.tin enlvr lotus tie,+ till t )r l ills, 1cr cnuul.(tilt I in,ha,e t 'ii,t,n. it dx end"t the 1 m am l"w".1 ill), A r elan(I0 '/'ferihow Option'-1. „r it i i I !hi, \-n omen!.Ind ha,,:tlae ti,,I erg r,m.,ci;n no,,,!i...'to" N.n,„ill need a,iennll Ill III ,=i,ni", u,_.min.II vletiuun lilt',Irn)/reel I'll"!a,the end of the icm, It 1-,,u cfe,t die I'ur.hao-e future¢ Cllr "pun dune Optiun pier* I,;,I h,, III,- Ibcit ntrrcni fi:i m.irk.l ,ethic „t U)c "N'Iem l"'end nn III ;nice rurnt q rii et , 0111ta 11 of imi,arh '11 d (,I e rt,. "'tent,m N ui the h(( a •r,,.i1 rill.n„,h t -pn„id d I„N ,a In .,in,i,r,l�he hmdin- 1: 11, gee;+t N„ur pa,mun,t the pu,c:w”Opi ,u i nci:.ei.,t,„i the alrj_ia(,al qu iwthl t rw,.a)rd all atlicr-uomlot,then ,rail : Ind,mt u I h...w i ill r lull a ut,le•r vt ( ill, t thw ti},t iw 1'.N'nc"1 the:.Ind 1 If /-rill - Ili i 1, kVIicre 1,-,b.t,i, It Sue ctrei i„hare(lie t.x:•, ,.7)o e,i. l\c uIII r;rnm,c Il,e ",,ICU,11"m'i ,in 'wp,f,, ,unun gun tr k'00 11,11 ,1tu lhe'.t„1ul Jrc I.nu. 11•NOf DO NOl N011FN I SOF viol R LI_F.('1loN to CAN(tl RN sl VI)INC: A P141flI N NOTICE: t0 CS, IHLN (fits V(.RI.3(\IFYI 1\11.1 At JO1t\TK \1I I RtNt.Av ON:AvF.:1R-to-I EAR 11AS1sINt1t NOt NO[Rill Is I's \\RIIIN(;OIv-ofRt:l.I,(-I ION TOCVN(Ft VI-IA1sTslV'T) (6111 1)1IS PRIOR 10 (1fF 1<NJ)011 lift RFNEN tl II(of. 1'- (RI.DI I (Ht('Ik I., ­!I tie 2,c.ut o thn t ic,n)rcr and at any time during the Tenn,You hereby authorize Us to(i)obtain Your credit rating and report from crcdu reperttmg �a ic,,fit),g, p Nei: payment performance under this Agreement to credit reporting agencies:and (iii)disclose this and other information to Out att`ihates and actual or prospective lenders.financing parties,investors,insurers,and acquirers WE MAY HAVE PRESCREENED YOUR CREDIT. PRF.SCREF.NING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING”PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE (888) 567-8688. SEE PRESCREEN & OPT-OUT NOTICE(SECTION 29)BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. F3,LINIFCED W, R_RANTY A. LiMiTED INSTALLATION WARRANTY- We provide a workmanship warranty that the System shall be tree from material defects in design and iP n4 hem 1 tiny conditions for the I ern We further warrant that all rooftop penetrations W. install shall be watertight as of the date of ;,t ,Im,r+, errty+..t_nt-.I b +,,,cii: x„ )r.i,', t­iq it,'Iddition to.not in lien ,_i„e i,r, ,I -,,,I.,.tt,l.iti.rte „c,au.•a>.., a;1,; tnrnn, n„t r nnri�r,!)° i I3. Al 1\(1 V( I RI lits' U VItR VN 14 I'; � m tl�;tr- ni i i s.t; ,:i , „r ie: 4 t.,,+n ,'Ili,gar ta,,fin nil,ti ,',:(0.r t th,,e.u.,+t =,c tti•. n. dt:k, .',,,r+r.J li,a.s 11 ,i ,s,1c l+, i tie:dire W,h,rc�-,l i I,Y i t-11i i x ills, tills r.m,•d„tu}rt,t :i:w i,I I i ire till ,rut -uI .ru i .,, h n =dal h.,In, i.: Iln l , it not i�rl h hr ni ( i it,n, ,,, t I re .I fi n lit il} r_tn3 n •„ t n.-,u, tier*:.+nv -unaunuu ,1.Ie �. i.r.t, -,t t,i i. ii.,.i (•.una,i...,i ,= 1*• 1 leak,.,i,r.t U,n(,r I ie I crrn 1ki <e r,.it,-an_1,.I,r Ill, 1 Iilc,,:,tent p,„il;, C. fuss 'I.Ali OF N\ARR.ANiY I .A( I P) SAS SI I fORIII I\ THIS Sf t ill\_3- Ui yl\Kl a t1THl k \4-A1tR VvIl 1O )(it (-)R ,\\) 01111P P( kSti0. VA"Ill IM K 151'RISS I\IPI If.D OR CL\11 fill,)- AS it) lilt \1f R( HAAI \111(.1 IIf CW It"f\ISS1(W IN) N`Rill)lit OI 1111 14)tJP\ll\1 IN51NI1 \I1(IN D1 ,I(.N, (ti'1RVII(Iv OR A1:A1\II\\\( I (it fill SYSTI \l. IIll PRUDt( I1O\ OR 0I A 1 k} 01 I NJ R(i',_ t)R VS) O1L11R \SS(!( 1171 D SI R\K I OR \1\1 CI it lit RI ('V`D1 R- ALi (it \6IiWII \\I 111 k111) I \PR0 tiI l S I)I',( I UM O 'k I I\till I1) I(W VAN HRI .A( 11 I)I it',", \\ \RR\NII IS 11\I1 I 1 1) i(I RLI'VIklA(i IIIf S)S11 \I (W )(4 R NO fill Rll It) IIIt I \il\1 RIlA'IRI1) t:\I)l k IflIS V'RIeAIt.NI )'Of' -lot,KN(1\\I I D(d Iii NI )lV'1 -Ak1 101 )JN(i t)N IIllti ',Id IfU", A_C' -AS \ IO\DIIhI\ A\I) \11iI RI AI I\Dli([\11 NI V) LAll R 1AJ(1 I111C \(,Rl I \i1 NJ iIll Rt \RI \0 A\1Rf{1NIlf 1 1V lilt` II 1 \111 Ni) R1 N'OND Tln DESCRIPTION CIF THE FACT HERV,01 4.REiv1OVAL OF THE SYSTEM You shall not make any Alterations(as defined in Sectioni_9Cc)))to the System. If You want to make repairs or improvements to Your Property that require the temporary removal of the System or that could inter lire wall its performance or operation,You must give Us at least thirty(30)days'prior written notice (a"Customer-Requested Shutdown")_ You agree that any repair or improvement to Your Property shall not materially after Your root where the System is installed. As compensation for Our removal,storage,and reinstallation of the System,You agree to pay to Us a tee equal to Four Hundred and Ninety-Nine Dollars($499)before We remove the System. You shall be required to pay the Shutdown Payment(as defined in Section 15)if the System is not reinstalled within thirty(30)days of removal. In the event of an emergency affecting the System,You shall contact Us immediately. if We are unable to timely respond,You may(at Your own expense)contract with a licensed and qualitted solar Installer to remove the System as necessary to make repairs required by the cmergencv. You shall be responsible for any damage to the System that results front actions taken by Your contractor_ —.__ -- 5.ARBITRATION OF D_iSPL'TES Most customer concerns can be resolved quickly and amicably, by calling Our customer service department at (1377) 404-4129. If Our customer service department is unable to resolve Your concern.You and We agree to resolve anyy Dispute(as defined below)through binding arbitration or small claims court instead of courts of general jurisdiction. BY SIGNING BELOW.�OU ACKNOWLEDGE AND AGREE THAT(1)YOU ARE HEREBY WAIVING THE RIGHT TO A TRIAL BY JURY;AND(I1)YOU MAY BRING CLAIMS AGAINST US ONLY IN YOUR INDIVIDUAL CAPACITY, AND NOT AS A PLAINTIFF OR CLASS MEMBER IN ANY PURPORTED CLASS OR REPRESENTATiVE PROCEEDING You and We agree to arbitrate all disputes, claims and controversies arising out of or relating to I mounting BOM Item no. Description Weight Quantity add. Items Sum 805-0010 Roof hook 170 standard 1.225 Ibs 44 0 44 720-0095 44 Head wood screw 6x80 1.236 Ibs 3 0 3 720-0818 100x rail fix.T-head M8 4.811 Ibs 1 0 1 702-0205 MEC CS RH 35mm 0.000 Ibs 8 0 8 700-0102 MC 30-40mm-w/Bonding Plate 0.000 Ibs 20 0 20 712-0136 Weeblug Alpha+pa 0.000 Ibs 4 0 4 807-0131 ACC Wire Management Clip 0.000 Ibs 0 0 0 807-0134 Omega Wire Management Clip 0.000 Ibs 0 0 0 712-0148 Rail/Microinverter Attachment-M8x20mm T-Bolt 0.000 Ibs 0 0 0 712-0147 Rail/Microinverter Attachment-M8x25mm T-Bol 0.000 Ibs 0 0 0 800-1085 BR 10/48 CS; 16ft 13.623 Ibs 4 0 4 800-1089 BR 10/48 CS;12ft 13.623 Ibs 4 0 4 706-0057 Splice,external,f.BR 10/48 CS 0.427 Ibs 4 0 4 Total 173.125 Ibs t m .c CL e[ Developer: Page 9 of 9 Date 4/27/2015 MS Version 2.0.32.0 (D (D 0 Ln 4 0 (-n 26.67 ft 3.71 ft 3.71 ft 6 5.42 ft .42 ft 3.71 ft 3.71 ft 3.00 ft 26.67 ft 3.00 It Field F---I Edges Corner rD -V Ln 0 (D 00 O O lD Alpha* '4r► mounting systems Construction � g �D N N C ? Q T t O O O E d C7 (7 l7 io II II II 4 ¢ m U X O r ry f0 a Q Developer: Page 7 of 9 Date 4/27/2015 MS Version 2.0.32.0 R mounting systems Configuration Fastener capacity Description Roof hook 170 standard Max. pressure load 112 Ibf Max.suction load -349 Ibf Max. lateral load 231lbf fastener distance 24.02 in Rail Description GS 10/48 Moment of inertia Iz 0.16 in^4 Moment of inertia ly 0.24 in^4 Resistance moment Wz 0.21 in^3 _a Resistance moment Wy 0.24 in^3 Cross section area 0.55 in^2 yield stress 21.2 ksi Modulus of elasticity 10100.0 ksi Load Rail Stress Deflection under load (%A=L/60) Length Load capacity Roof area (%yield) Rail Cantilever Cantilever Attachment Field 7.3 % 1.7 % 5.9 in 90.0 % Edges 7.3 % 1.7 % 0.0 in 90.0% Comer 7.3 % 1.7 % 0.0 in 90.0 % The system was successfully verified. Notes • Only the statics of the solar substructure are analyzed.The rails are designed as multi-box girders with cantilever, and uniform load distribution • The values for material durability are taken from the technical manual of the manufacturer. Developer: Page 6 of 9 Date 4/27/2015 MS Version 2.0.32.0 r mounting syst: rrlS Module field layout Module manufacturer TrinaSolar Module length 65.0 in Module type TSM-255 PC05A Module width 39.1 in Module power 255.00 Watt Frame height 1.4 in Number of modules 12 Modul weight 41.01 Ibs Module orientation Portrait Overall power output 3.1 kWp h fY r.4e t5 fi!0 07 n 4 n i 46:f Y 1 a 6tts6n.n I I h I I I ft tt.40 in ti I i - R R 7Jq In ?! .r. + Developer: Page 5 of 9 Date 4/27/2015 MS Version 2.0.32.0 w mounting systems Load combinations (ASD) LFK1: Ed=D LFK2: Ed=D+L LFK3: Ed=D+(L,or 5 or R) LFM Ed=D+0.75*L+0.75*(L,orS or R) LFK5: Ed=D+(0.6*W or 0.7* E) LFK6a: Ed=D+0.75* L+0.75*(0.6*W)+0.75*(Lr or S or R) LFK6b: Ed=D+0.75* L+0.75* (0.7*E)+ 0.75*S LFK7: Ed=0.6* D+0.6*W LFK8: Ed=0.6* D+0.7*E max action [lb/ft'] Roof area Pressure Pressure Suction Suction orthogonal parallel orthogonal parallel Field 16.980 10.000 -7.987 0.837 M M CL Edges I 16.980 10.000 -9.815 0.837 Corner I 16.980 10.000 -9.815 0.837 max action per unit length of rail [Ib/ft] Roof area Pressure Pressure Suction Suction orthogonal parallel orthogonal parallel Field 45.960 27.080 -21.620 2.266 Edges 45.960 27.080 -26.570 2.266 Corner 45.960 27.080 -26.570 2.266 Developer: Page 4 of 9 Date 4/27/2015 MS Version 2.0.32.0 1 *W mounting systerris Loads Snow load Importance factor II: 1.00 Ground snow load pg= 40.000 Ib/ft2 Shape factor C,= 0.523 Snow load -flat pf= 28.000 Ib/ft2 Snow load -sloped ps= 14.650 Ib/ft2 Wind load Basic wind speed v= 100.00 mph Terrain category B: Urban and suburban areas,wooded areas,or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. Wind Gust Velocity Pressure q= 15.230 Ib/ft2 m r Roof areas ° Distributed Wind Loading per Base Rail Pressure [lb/ft] Suction [lb/ft] Field 37.115 -41.239 Edges 37.115 -49.486 Corner 37.115 -49.486 Dead load Module area Arv,= 17.62 ft2 Modul weight Grv,= 41.01 Ibs Dead load gm= 2.373 Ib/ft2 Developer: Page 3 of 9 Date 4/27/2015 MS Version 2.0.32.0 R Will- mounting Building data Site data Country USA IBC 2012 Terrain height 0 ft Building specifications Roof type Gable roof Building length 32 ft 8.00 in Building width 22 ft 4.59 in Building height 25 ft 0.00 in Roof specifications Roofing Curved tile Rafter width 2.0 in Roof pitch 36° Rafter height 6.0 in Rafter spacing 24.0 in n. cel- 25�4��n 1 � i titi Developer: Page 2 of 9 Date 4/27/2015 MS Version 2.0.32.0 mounting systerns Project Information Contact Name 4211429 Street address 7 Berkshire Ter City,State,ZIP Florence, MA,01062 Phone Email m s CL Q Developer: Page 1 of 9 Date 4/27/2015 MS Version 2.0.32.0 R D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 10.8 amps Continuous current adjustment factor 125% 2011 NEC Article 705.60(B) PV circuit continuous current rating 13.5 amps 2.Overcurrent protection device rating PV circuit continuous current rating 13.5 amps Next standard size fuse/breaker to protect conductors 15 amp breaker Use 15 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 37.40C (99.32-F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(B) Adjusted maximum ambient temperature 59.4°C (138.92°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 59.4°C (138.92°F) 71"-0 2011 NEC Article 705.60(B) Adjusted PV circuit continuous current 19 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 3 conductors Conduit fill derate factor 100% 2011 NEC.Article 705.60(B) Final Adjusted PV circuit continuous current 19 amps Total derated ampacity for PV circuit 19 amps Conductors(tag2 on 1-line)must be rated for a minimum of 19 amps T11WN-2(90°C) #12AWG conductor is rated for 30 amps (Use#12AWG or larger) 2011 NEC Article 705.60(B) 4.Voltage drop(keep below 3%total) 2 Darts: 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors(from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.41% The largest number of micro-inverters in a row in the entire array is 12 inCircuit 1. According to manufacturer's specifications this equals a voltage drop of 0.41 `Yo. 2.AC conductor voltage drop: = I x R x D (=240 x 100 to convert to percent) _ (Nominal current of largest circuit)x(Resistance of#12AWG copper)x(Total wire run) _ (Circuit 1 nominal current is 10.8 amps) x (0.0020152)x(90') - (240 volts) x(100) 0.8111%0 Total system voltage drop: 1.22% 3. Electrical Components: A. Module (UL 1703 listed) Qty Trina TSM 255-PA05.18 12 modules Module Specs Pmax-nominal maximum power at STC - 255 watts Vmp-rated voltage at maximum power - 30.5 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.36 amps Isc-rate short circuit current - 8.92 amps B. Inverter (UL 1741 listed) Qty Lnphase M215-60-2LL-S22 12 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(D(.) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max. start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 1 PV circuit 1 - 12 modules/inverters (15)amp breaker 2011 NEC Article 705.60(6) vivin Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Proiect Information Project Name: Larysa Bachinsky Project Address: 7 Berkshire Ter,Florence MA A.System Description: The array consists of a 3.06 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.'There are(12) 255-watt modules and(12)215-watt micro-inverters,mounted on the back of each PV module.The array includes(1) PV circuit(s).The array is mounted to the roof using the engineered racking solution from Mounting Systems Inc.. B.Site Design Temperature: (From Boston Logan Int'I AP weather station) Average low temperature: -19.7°C (-3.46°F) Average high temperature: 37.4°C (99.32 OF) C. Minimum Design Loads: Ground Snow Load: 40 psf (ASCF 7-10(7.2)) Design Wind Speed: 100 mph (ASCE 7-10(26.5.1)) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: EcoX Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B.Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Mounting Systems Inc. b.Product Name: Alpha+ c.Total Weight of PV Modules,MicroInverters,and Racking: 604.8 Ibs d."Total number of attachment points: 20 e.Weight per attachment point: 30.24 Ibs f.Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 211.32 square feet h. Array pounds per square foot: 2.86 Ibs square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (12)modules,(20)attachments 28.2 pounds/attachment . Inverter Ratings(Guide Section 4) Conduit and Conductor Schedule Inverter Make/Model Enphase M2156G-2LL-S22 Tag Description Wre Gauge Mot GOntlUUOrs Conduit Type Conduit Size MODULE DETAIL Max DC Volt Rating 45 Volts 1 Enphase engage cable-THWN-2 12 AWG 4 Cord N/A-Free Air Max Power a 40°C 215 Wads U o Nominal AC Voltage 240 Volts 1 Bare Copper Ground(EGC/GEC) fi AWG 1 N/A-Free Air N/A-Free Air o r TrinaTSM-255PA05.18 Max ACCurtenl 1.125 Amps 2 THWN-2 OAWG 3 PVC 1.• Al N SOLAR MODULE Max OCPD Rating 20 Amps W Max Number of Panels/Circuil 17 2 THWN-2-Ground a AWG 1 PVC 1" m 3 THWN-2 10AWG 3 PVC 1•• A•w Ire NOTES FOR INVERTER CIRCUITS(Guide Section 8 and 9): 3 THWN-2-Ground 8 AWG 1 PVC 1•• W/ o W 1.)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS LL`r PV Module Ratings @ STC(Guide Section 5) z M:5 SWITCH MEET THE REQUIREMENTS? x Z Model Make/Model Trina TSM-255 PA05.18 Enphase M215-60-2LL-S22 YES NO X NA y�I- Max Power-Point Current(Imp) 8.37 Amps m,Z MICRO-INVERTER AT Y 00 o z 2.)IF GENERATION METER REQUIRED,DOES THIS METER Max Power-Point Voltage(Vmp) 30,5 Volts O EACH MODULE,ATTACHED N SOCKET MEET THE REQUIREMENTS? �U WITH ECO HARDWARE YES NO X NA Open-Circuit Voltage(Ise) 38.1 m s U . Short-Circuit Current(Ise) 8.88 Amps Q 3.)SIZE PHOTOVOLTAIC POWER SOURCE(DC)CONDUCTORS Max Series Fuse(OCPD) 15 Amps BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum Power at STC(Pmax) 255 Watts (� RATING AT DISCONNECT. Maximum System Voltage 1000(IEC)1600(UL) C j 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING V.Temperature Coefficient -045 W'C W MICROINVERTER CONNECTION ^ TO INVERTER OCPD AMPERE RATING(See Guide Section 9). TO ENGAGE TRUNK CABLE V 5.)TOTAL OF 1 INVERTER OCPD(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 8 and Appendix D): PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expected ambient temperature based on ASHRAE minimum mean extreme NEC 690.64(B)(2)(a)? X YES NO dry bulb temperature for ASHRAE location most similar to installation location: -26.9°C #6 BARE CU GROUND Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb (GROUNDING ARRAY) temperature for ASHRAE location most similar to installation location: 32.5°C - - -- - Sign for inverter OCPD and AC Disconnect: 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47°C in the United Stales(Chicopee Falls,MA is 33.2°C).For less than 9 current-carrying conductors Solar PV System AC Point of Connection in roof-mounted sunlit conduit at least 0.5"above roof and using the outdoor design AC Output Current 13.500000 1 Amps temperature of 47°C or less(all of United States). Nominal AC Voltage 1 2401 Volts a.)12 AWG,90°C conductors are generally acceptable for modules with Ise of 7.68 Amps Now THIS PANEL FED BY MULTIPLE SOURCES or less when protected by a 12-Amp or smaller fuse. N (UTILITY AND SOLAR) b.)10 AWG,90°C conductors are generally acceptable for modules with Ise of 9.6 Amps N or less when protected by a 15-Amp or smaller fuse. • v Inverter's are equipped with rapid shut down B NEC 2014 Section 690.11 DC Arcfault circuit protection.Enphase micro inverters are exempt from NEC 690.11 due to operating voltages are well below required for Arc-fault protection. m All labeling as per NEC 2014 a LOCKABLE m n ENVOY BOX DEDICATED g m o SERVICE O O M , Lu Lu `� OUTLET EXISTING wP ENTRANCE j 2 U) CONDUCTORS > z uj 5 RATED:100A W x (n > SIEMENS � w Lu °� \0 0 COMBINER 30A/240V SIEMENS F J \G G PANEL 60At240V UNFUSED 30AI240V U) U) a < p0\d'F20 4 SPACES NEMA3 FUSED/NEMA3 SUPPLY-SIDE ? ? o O\ LWO04NR SREC/ANSI LNF222R OR GF222R OR SOLAR TAP SHEET PV CIRCUIT 1: 12 MODULES/PARALLEL \��L OR EQUIVALENT METER EQUIVALENT EQUIVALENT NEC 705.12(A) NAME: go\tt`POC! 1z 0 (D \� Z Ix \\ :3 Q 15A f7 E 1.0 15A\ SHEET 240V/100A NUMBER: ---- - --\-------- ------ - -- ------- -- - ------- -- - ------- PANEL \\ MILBANK VISIBLE/ j EXISTING O JUNCTION BOX 2 \\ 3 100A OR 3 LOCKABLE 3 3 I LOAD NEC 2014 Compliant WITH IRREVERSIBLE E 1.0 \\ E 1.0 U 934-XL BIG E 1.0 DISCONNECT E 1.0 E 1.0 CENTER w GROUND SPLICE - U C N r N 7! N V N N PV MODULE,TYP.MOUNT N�8 TO RAFTERS OF COMP. N o W SHINGLE ROOF,PARALLEL L-FOOT WITH CONNECTION m t j WITH PLANE OF ROOF z m z OOU Seca°z MID CLAMP DETAIL "� Nr L) FLASHING WITH z� C a WATERPROOF SEALANT m '3 DETAIL NOT TO SCALE '� O iv O Pva.o O U 0 --- --- m 5/18"Oz 4 1/2"MINIMUM STAINLESS STEEL LAG SCREW TORQUE=13±2 ft-IDs. PV ARRAY TYP. ELEVATION END CLAMP DETAIL NOW NOT TO SCALE L-FOOT DETAIL o NOT TO SCALE ro 2 " NOT TO SCALE `3 • n N V W w O PERMITTED LEVELING L-FOOT WITH CONNECTION FOOT SPACING J END CLAMP N FRAMING BELOW SHOWN END CLAMP Y DASHED FOR CLARITY N 1 PHOTOVOLTAIC MODULE pV4.0 of n Y I gcDav 1 ( 1 I END CLAMP U) U� 1 1 1 I I I I PHOTOVOLTAIC MODULE z Q 1D I I 1 I I I I 1 I I 1 I 1 I I 1 I CANTILEVER=U3 L=PERMITTED SPACING j Z I I I OR LESS VERIFY WITH QUICK CONFIGURATOR OUTPUT W Lu LU N 1 J W z m m W I I I I I I I I I I I I I F- r 1 I I I I I I I Z o I 1 I I I j I I I I I I I NAME: I I I I I I I I I I I I I I I I I I J 1 L+ OT WITH MID CLAMP L-FOOT WITH CONNECTION Q CONNECTION O w 1 I I I I I 1 MID CLAMP PERMITTED LEVELING PV4.0 ROOF FRAMING C FOOT SPACING PV SYSTEM MOUNT DETAIL SHEET NUMBER: I SCALE:N.T.S. MODULES IN PORTRAIT/LANDSCAPE ° M NOT TO SCALE > 0 x z D m °a °o O ��O �c(p .50 wO V V_1 = A m z N Z m W j w O m m N� KC) 0 0 C n r C C Cn n D C r m Cn � w Cn m II r C) 3 O z O In m z v z C= n C/) INSTALLER:NUMBER:SOLAR • • Bachinskv Residence w m ROOF m m INSTALLER NUMBER:1.877.404.4129 � � PV 2,0 m m MA LICENSE:MAHIC 170848 ; 7 B reshire Ter Florence,MA 01062 PLAN N DRAWN BY:WES S-4211429 Last Modified:4/27/2015 UTILITY ACCOUNT NUMBER:78222-47000 D r 7 Berkshire Ter_, Florence MA 01062 �m7 1Dm z o o ��v� S � City C3 M Q �? Cv of Northampton ° I �/ I Building Department I m m Z 0 mO ° �" � Plan Review i A �D= fn o m o I 212 Main Street 00--1 ° o I 1 Northampton, MA 01060 1 0 5 0 Z Z2 I I II 1 ' I I I I ' O, ro ( I Z' . I --i. 3 I b Z N N I O3 a ( 1 I )v �r ID r° xN� I 1 I 030 ( I o =qm I m Om� I 1 O A mAD I I I I I I T O I � KO `C Z-u I -j0 I 0 C) z 0 I MZ W Z �0 c 0 I M I I C) W T D Q < Z I C� C/) � m I cn cn I m y < I n � m -< N w I N c m N m cn �- - - - - - - - - -- _ =i M z z rn z m INSTALLER:VIVINT SOLAR BachinskY Residence m SITE m MA LICENSE:MAHIC 170848404.4129 7 B€rkshire Ter PV 1.0 m Florence,MA 01062 PLAN DRAWN BY:WES IRO Last Modified:4/2712015 UTILITY ACCOUNT NUMBER:78222-47000 Page 2of2 B. Loading Criteria 10 PSF= Dead Load roofing/framing 40 PSF= Live Load (around snow load) 5 PSF= Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2009 International Residential Code. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Mounting System Inc. Installation Manual", which can be found on the Mounting System Inc. website (usa.mounting- systems.info/en/solar-mounting-systems-company). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 1/2"thick and mounted 4 1/2'off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher that 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than the maximum allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2' with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts will be adequate with a sufficient factor of safety. 4. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every other roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than two (2) rafter spaces or 48" o/c, whichever is less. 5. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code, current industry standards and practice, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. OF Ve ruly yours, ecyG 4 ' Ali i cwi Cn Scott E. Wyssli , PE 0 50 MA License No. 505 90� FcIsTEPti FSS10NA1. i e • vivint. 3301 North Thanksgiving Way, Suite 500 Structural Group Lehi, LIT 043 P P: (801)234-7-7050 Scott E. Wyssling, PE Head of Structural Engineering scoff.wyssling@a vivintsolar.com April 29, 2015 Mr. Dan Rock, Project Manager Vivint Solar 150 Padgette Street, Unit A Chicopee, MA 01022 Re: Structural Engineering Services Bachinsky Residence 7 Berkshire Ter, Florence MA S-4211429 3.06 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2x6 dimensional lumber at 24" on center. The attic space is unfinished and the photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached MSI calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 90 mph based on Exposure Category"B" and 36 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure "B", Zone 3 per (ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivint. The Commonwealth of Massachusetts Department of Industrial Accidents r Office of Investigations 1 Congress Street,Suite 100 ' Boston,MA 02114-2017 www mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): Vivint Solar Developer, LLC Address:3301 North Thanksgiving Way,Suite 500 City/State/Zip:Lehi, LIT 84043 Phone#:801-377-9111 Are you an employer?Check the appropriate box: Type of project(required): 011 I am a employer with 214 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. E]New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have g_ ❑Demolition working for me in any capacity. employees and have workers' g ❑Building addition [No workers' comp.insurance comp.insurance? required.] 5. ❑ We are a corporation and its 10.❑Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.]t c. 152,§1(4),and we have no Solar Installation employees. [No workers' 13.❑Other comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. ;Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins. Lic.#:WC 509601300 Expiration Date:11/1/2015 Job Site Address: City/State/Zip:_ Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct Signature: Date:11/4/2014 Phone#: 801-2296459 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: John A Jalbert CS070940 License Number 150 Padgette St Unit 0. C iCO ee 01022 3/25/201' Address Expiration Date 413-331-0769 Signature Telephone 9.Reaistered Home Improvement Contractor: Not Applicable ❑ Vivint Solar Developer/John A Jalbert -70i''` Company Name Registration Number 49 1 N `inn W. Provo UT 84604 ira o�1������ Address Ex n Date Telephone 413-331-0769 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780 Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature r SECTION 5-DESCRIPTION OF PROPOSED WORK lcheck all applicable) New House ❑ Addition ❑ Replacement Windows Alterations) ❑ Roofing Or Doors Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [[] Siding[p] Other(p] Brief Description of Proposed WorkA Installation of roof mounted photovoltaic solar systems#of modules + CA cx,�. t e rnQi ?erwii I n - e,�veAcw 7CXc . Alteratio of existing bedroom Yes No Adding new bedroom--Yes o Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building:One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No i. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1, as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I, Vivint Solar Developer as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Savina Cervone Print N _ �"Ow P&YLA V S1 Fef0mier/Agent Date x Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning Phis column to be tilled in by Building Department Lot Size Frontage Setbacks Front Side L: R:_ L:_ R:__ Rear Building Height Bldg.Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Loration) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DON'T KNOW © YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Department use only of Northampton Status of Permit: ing Department Curb Cut/Driveway Permit 212 Main Street Sewer/Septic Availability 0 Room 100 WaterMell Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address, This section to be completed by office '7�erk Shi r� �� �/ Map Lot Unit F/Or we/ �A �I LNJr Zone Overlay District Elm 5t.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: ar�-cs �6 cich i osku 'm e r Name(Pri C ai re Telephone Signature 2.2 Authorized Aaent: Savina Cervone 150 Padgette St, Chicopee, MA 01022 Name(P' Current Mailing Address: 413-331-0769 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only complete by ermit applicant 1. Building J# (a)Building Permit Fee 2. Electrical (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) Check Number This Section For Official Use Only Building Permit Number: IDssued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2015-1081 APPLICANT/CONTACT PERSON VIVINT SOLAR DEVELOPER LLC ADDRESS/PHONE 150 PADGETTE ST UNIT B CHICOPEE01022(413)331-0769 PROPERTY LOCATION 7 BERKSHIRE TER MAP 23B PARCEL 066 001 ZONE URB(100) THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: INSTALL 12 MODULES ROOF MOUNTED SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 070940 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOR TION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management D ition Dela gnature of Buil ing Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 7 BERKSHIRE TER BP-2015-1081 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 23B -066 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2015-1081 Project# JS-2015-002049 Est.Cost: $15300.00 Fee: $92.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group VIVINT SOLAR DEVELOPER LLC 070940 Lot Size(sq ft.): 19906.92 Owner: BACHINSKY LARYSA C Zoning: URB(100) Applicant: VIVINT SOLAR DEVELOPER LLC AT. 7 BERKSHIRE TER Applicant Address: Phone: Insurance: 150 PADGETTE ST UNIT B (413) 331-0769 WC CHICOPEEMA01022 ISSUED ON.511112015 0:00:00 TO PERFORM THE FOLLOWING WORK.INSTALL 12 MODULES ROOF MOUNTED SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeTyne: Date Paid: Amount: Building 5/11/2015 0:00:00 $92.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner