17C-253 (9) Cellar Carbon monoxide detector 1038 T-0 K Comments: 1)CO2 Detector at base of cellar stairs is continually beeping—This device is not part of fire alarm system,but should be replaced If you would like the deficiencies above repaired on a time and material basis please initial next to the repairs you would like corrected,then print,sign,and date below. Request for repairs can be faxed or emailed to our office RE, Clinical Support Options Customer Printed Name: Authorized Signature: Date: Page 3 of 3 Are the smoke detectors sensitivity test results within the devices marked range or 4%obscuration light gray smoke? N Are all alarm notification appliances free of damage and operate per manufacture specifications? Y Have all magnetic door holders been tested, and found to be operating satisfactory? NA System annunciators are identified and operating correctly? Y SYSTEM SUPElZV15lC?N, NI3 MONlTt ARING: Qid the supervision station receive the correct initiating device within 90 seconds? Y Did the fire department receive a signal from the communicator or city box? Y Location Device Type Device#f Results Tamper water flow Module Supervisory 8701 1001 OK First floor front entry Module Supervisory 870 1002 OK First floor front stairwell Smoke detector 8710 1003 OK First floor left office Smoke detector 8710 1004 OK First floor left Pull station 8700D 1005 OK First floor living room Smoke detector 8710 1006 OK First floor Carbon monoxide detector Aug-13 1007 OK First floor center hall Smoke detector 8710 1008 OK First floor left bedroom Smoke detector 8710 1009 OK First floor center stairwell Smoke detector 8710 1010 OK First floor kitchen hall Smoke detector 8710 1011 OK Kitchen exit Pull station 8700D 1012 OK First floor waiting area Smoke detector 8710 1013 OK Waiting area Pull station 8700D 1014 OK First floor rear office Smoke detector 8710 1015 OK First floor rear office left Smoke detector 8710 1016 OK Rear exit Pull station 8700D 1017 OK Second floor front Smoke detector 8710 1018 OK Second floor front Carbon monoxide detector Aug-13 1019 OK Second floor conference room Smoke detector 8710 1020 OK Second floor left Pull station 8700D 1021 OK Second floor right front bedroom Smoke detector 8710 1022 OK Second floor front hall Heat detector-Combo 8713 1023 OK Second floor center hall Carbon monoxide detector Oct-13 1024 OK Second floor right side bedroom Heat detector-Combo 8713 1025 OK Second floor center Carbon monoxide detector Aug-13 1026 OK Second floor center stairwell Heat detector-Combo 8713 1027 OK Second floor center stairwell Pull station 8700D 1028 OK Second floor left bedroom Heat detector-Combo 8713 1029 OK 2nd floor rear stairs Pull station 8701 1030 OK Second floor left office Heat detector-Combo 8713 1031 OK Second floor rear office Smoke detector 8710 1032 OK Second floor office Smoke detector 8710 1033 OK Second floor rear exit-Office right Pull station 8701 1034 OK Second floor rear office Smoke detector 8710 1035 OK Bottom of cellar stairs Smoke detector 8710 1036 OK Above FACP Smoke detector 8710 1037 OK Attic Stairs Smoke detector 8710 1039 OK Page 2 of 3 j MA#1452 845 Airport Industrial Park Road Westfield, MA 01085 Phone 413-568-3547 Fire Alarm inspection &Test Report Customer: Clinical Support Options Address: 29 North Main Street, Florence, MA Date of Inspection: 11812015 Inspector Bob Pevlin&Sean Schnopp Nicet# 198375 Customer Contact: Lisa or Paul Location Phone Number: 413-586-2973/Office#586-5382 System Normal Upon Departure: YES "Signature on file" Panel Location: basement Panel Model: Faraday MPC 6000 System Type: Addressable Fire Department: Northampton Fire Department Monitoring Company: Account# : 1551019-Affiliated Central SLC: 1 Loop 252 Points SLC Type: Class B Heat Detector Type Pull Station Type/Style 8700D Smoke Detector Type/Style: 8710&8713 Main Powers 120v 15amp Disconnect Location: Basement Panel I CKT# 23 Auxiliary Power: (2) 12 volt 18amp hr 1/2015 Battery Voltage: 27.7V Battery Drain Voltage Before: 27.1V Battery train Test Voltage After: 125.7V Procedure Used to Perform Voltage Drain Test? lin Accordance with NFPA 72 Chapter 14 Section 9 Remote Annunciator: JRDCI Located in Main Hall YIN NA Y=Satisfactory N=Unsatisfactory N/A=Not Applicable FIRE ALARM CONTROL PANEL: Are all the alarm zones labeled at the control panel? y Do all control panel lamps and LEDs illuminate? y Are control panel terminations secure? y Does an open wiring on initiating or indicating circuits cause panel to go into trouble? Y Does the earth ground detection work properly? y Is the location of breaker feeding the alarm panel been identified? y Does the control panel go into trouble with loss of AC feed,or loss of battery power? Y SYSTEM BATTERIES: Are system batteries free of leaks or corrosion? y Are battery charging systems operating correctly and in the state of charge? Y Are system batteries within manufactures replacement dates and/or proper current or voltage recommendations? Y SYSTEM?COMPONETS: . ' Have. smoke detectors been checked for sensitivity at the proper intervals? N Page 1 of 3 Mal [ichvPlumbing& Heating Inc. 14 Conway Street/PO BOX 94 South Deerfield, MA8lB7S 413-773-0734 March 2@i2O15 [SO-Administrative Ofhcey 8Atvvood Drive Suite 301 Attention: Paul Arsenault Northampton, K8Al06O Work Location:29 North Main Street, Florence, MA Boi|er#1'HB Smith BmilerS/VV-6 Relief Valve---------------Ok Low Water Cutoff-----CJk Change Site Glass-------[]k install chemical to condition water in boiler(EZ Steam Conditioner)----------Ok Boiler#2-Crain Sunny Day 7'1Q2Gas Install 911SFedderBachflmvvPreventer Install 30 pound 37A Pressure Relief Valve Install 2 Taco#6H| Vents Check Cemented Chimney around flu to prevent carbon monoxide Check 3 Bradford White SD Gallon Natural Gas Water Heaters Vent, Relief and Temp------------[)k KUa| C}chy ' "PROVIDING EXCELLENT SERVICE FOR OVER 65 YEARS" MASSACHUSETTS FIRE TECHNOLOGIES, INC. 57 YORK.STREET, WEST SPRINGFIELD, MA 01089 P.O. BOX 8, WEST SPRINGFIELD, MA 01090 (+++ F (413)731-8000* FAX(413) 746-9570 www.massfire.com *EXTINGUISHER SERVICE *24 HOUR SERVICE •HALON ALTERNATIVE SYSTEMS *ANSUL SYSTEM *FREE SURVEYS *TRAINING CLASSES Clinical & Support Options April 21, 2015 29 North Main Street Florence, MA Aft: Paul Arsenault parsenault @csoinc.org Paul ; Thank you for choosing Massachus6ffs Fire Technologies to take care of your extinguishers for the above address. The fire extinguishers have been"inspected per NFPA 10 codes and are on an annual schedule for March of each,yeel At the present time your thirteen extinguishers are in compliance and were last inspected during the month of March 2015. Please do not hesitate to call'.If u,have any questions or concerns. Sinceely Susan Trystas Susan Przystas General Manager SBPfcmm l FIRE CERTIFICATE OF INSPECTION Name of Facility Address of Facili Was inspected on 7-/ CL-j(<�: Date Name of Inspector I HEREBY CERTIFY THAT THIS FACILITY COMPLIES ALL STATE FIRE CODES AND LOCAL ORDINANCES. YES NO If answer is "NO", indicate violations and recommendations. Violations: Recommendations: ISSUED 6Y: e Signature: Head of Fire Department Or his designee r