12-022 (4) Safety Clearances READ ALL INSTRUCTIONS BEFORE INSTALLING Masonry or Factory Built Fireplace AND USING THIS APPLIANCE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, The minimum required clearances to surrounding combustible BODILY INJURY, OR EVEN DEATH. materialswhen installed into a masonry orfactory built fireplace are listed below and in Fig.#1. We strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequently.This may be due to curing of stove paint or fumes caused by accidentally leaving the fire door open. Do not disconnect the detectors. Minimum Clearances to Combustibles If necessary, relocate them to reduce their sensitivity. SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the installation Adjacent Sidewall...................................13 1/2 in.(343 mm) directions.Consult local building or fire officials about restric- antel(measured from top of brow).............16 in.(406 mm) tions and installation inspection requirements in your area. The services of competent installer, certified by the Wood Top Facing..............................................16 in.(406 mm) Energy Technical program (WETT)-in Canada, Hearth Edu- Side Facing........................................9 3/4 in.(248 mm) cation Foundation (HEARTH) - in U.S.A. (or equivalent) are Ceiling...............................................................70 in.(1.8m) strongly recommended. Dimensions 29 112" 2 7/8" 36' 749mm 6�� �914mm �_6 6mm 159 mm 211/16" 26 101/81, 0 19 3/4" 5 0 mm 660mm 257mm 502 20 11/16" 16 _I 3 7/16" 526mm ;495mm 08mm 87mm 24" 19 1/2" 610mm 27 9/16" 700mm __-------- ....... _ F% # MINIMUM 70"FROM BASE OF 9 UNIT TO CEILING an a or op acing j MANTEL DISTANCE MEASURED FROM TOP OF 6° SURROUND BROW SIDE FACING AND ADJACENT C WALL MEASURED FROM EDGE OF DOOR LL, eat 1 1/2" N Adjac 43mm 248rarn Ala i Hearth k18, 457mm 141014-20 NEO1.61NSERT-A ©PACIFIC ENERGY FIREPLACE 3 PRODUCTS LTD. �k Fireplace hearth requirements: (Measured without the insert) The hearth can be flush with an adjacent combustible floor and must extend 16"in front and 8"beyond each side of the fireplace opening. MINIMUM FIREPLACE OPENING AND HEARTH DIMENSIONS 16" _ Q 30" 406mm 762mm 20" ............ 508rr m 24 16 1/4" 629m m� 413mm 16 1/4 Non-combustible f replace 413mm hearth 20" 8" 8" 508mm 203mm 203mm e• ** Ember protection: Combustible floor in front of the fireplace insert must be protected from hot embers by non-combustible material extend- ing 16" (USA) and 18"(CANADA)to the firing side and 8"to other sides of the unit. Consult CAN/CSA-13365 Installation Code for Solid-Fuel-Burning appliances and equipment in Canada, and N.F.P.A. 211 Standard for chimneys,fireplaces,vents and Solid-Fuel-Burning appliances in USA. MINIMUM EMBER PROTECTION DIMENSIONS 16 7/8"(429mm) USA 18 7/8"(479mm)CANADA 16"(406mm) USA Non-combustible hearth 18"(457mm)CANADA Non-combustible floor covering 4 ©PACIFIC ENERGY FIREPLACE NEO1.61NSERT-A 141014-20 PRODUCTS LTD. City of Northampton (C - � Massachusetts ;.x � 3 2015 DP TMENT OF BUILDING INSPECTIONS I Main Street • Municipal Building Northampton, MA 01060 sl,� y1 ectric, Plumbing&Gas Inspections Northagrin—MA 01060 SINGLE OR TWO FAMILY SOLID FUEL APPLIANCE PERMIT APPLICATION FOR WOOD, COAL, PELLET, CORN, STRAW OR SIMILAR STOVES, OR FIREPLACE INSERTS Permit Fee: $25.00 Check # eT 3 PLEASE TYPE OR PRINT ALL INFORMATION 1. Name of Applicant: Address: 1D6 1:�A-4- I7� JAAha/I Telephone: q1 2. Owner of Property: Address: �0&04f,/ u," 1' Po/'-nCC, Telephone: 3. Status of Applicant: Owner Contractor 4. Type or Brand of Stove:�Iocr ht-c Vc-0 /. "J l(C !�j21GCC j/1 5ert 110&1A3`lfai!j 1 If applicant is not the homeowner: Construction Supervisor's License Number `�9`/ Expiration Date Home Improvement Contractor Registration Number 77 Expiration Date All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit 5. Certification: I hereby certify that the information contained herein is true and accurate to the best of my know,l/edge. DATE: APPLICANT'S SIGNATURE -��-----� DATE: - ^��^ HOMEOWNER'S SIGNATURE APPROVED DATE: BUILDING OFFICIAL 31 COUNTRY WAY BP-2015-0962 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 12-022 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL 042A) Category: woodstove BUILDING PERMIT Permit# BP-2015-0962 Project# JS-2015-001864 Est. Cost: Fee: $25.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: BERNARDSTON FARMERS SUPPLY 99401 Lot Size(sq. ft.): 19994.04 Owner: PHILLIPS DAN Zonin : Applicant: BERNARDSTON FARMERS SUPPLY AT. 31 COUNTRY WAY Applicant Address: Phone: Insurance: 43 RIVER ST (413) 648-9311 () WC BERNARDSTONMA01337 ISSUED ON:411412015 0:00:00 TOPERFORM THE FOLLOWING WORK.INSTALL PACIFIC ENERGY SUMMIT FIREPLACE INSERT (DOWNSTAIRS) POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy SiEnature: FeeType: Date Paid: Amount: Building 4/14/2015 0:00:00 $25.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner