16D-004 (3) City of Northampton Mail-RE: 206 North Main Street-Building Permit https://mail.google.com/mail/u/0/?ui=2&ik=39211afc3d&view=pt&s...
Chuck Miller
Assistant Building Commissioner
City of Northampton
Town of Williamsburg
(City of Northampton E-mail is a public record except when it falls under
one of the specific statutory exemptions. )
Chuck Miller
Assistant Building Commissioner
City of Northampton
Town of Williamsburg
(City of Northampton E-mail is a public record except when it falls under one of the
specific statutory exemptions. )
2 attachments
206 NORTH MAIN STREET REVISED PLAN APRIL 2015.pdf
1335K
BEAM DESIGN CALC.pdf
1472K
4 of 4 4/8/2015 11:53 AM
City of Northampton Mail-RE: 206 North Main Street-Building Permit https://mail.google.com/mail/wu/'(w=2&iic=sy/-iiaic.)ua,virw pwc.�,...
To: aimua @hotmail.com
Hi,
I'm not ready to give the go for the foundation.
There is a requirement for lighting and ventilation for the basement done either
with windows or artificial lighting and mechanical ventilation.
Other items that need to be addressed.
please provide an electronic plan set
bearing location from the 2nd floor need to be indicated at the 1 st floor level
-joist layouts and LVL calculation must be provided.
the 2 x 12 at the 1st floor level appear to meet the span allowance, but realize
the allowable deflection is about 5/8" so it should feel like a trampoline.
there is not a framing details for the deck and piers.
Please provide the above items.
Chuck Miller
On Mon, Mar 30, 2015 at 9:17 AM, joseph aimua <aimua @hotmail.com>
wrote:
Mr. Louis Hasbrouck/ Chuck Miller:
Building Commissioner/ Assistant Building Commissioner
Dear Sir,
Attached is a revised foundation/wall for the above
referenced new building plan. Revision to the plan is 8"wall to
10"wall for all the walls and#6 bar steel reinforcement for the
interior wall only as noted on the plan.
Is it possible sir for me to start foundation/wall while waiting for
the building permit? I am running behind in construction
schedule. I will be greatly appreciate your effort if my request
is granted.
Yours Sincerely,
Joseph Aimua, P.E., S.E.
Joslad &Associates, P.C.
Chuck Miller
Assistant Building Commissioner
City of Northampton
Town of Williamsburg
(City of Northampton E-mail is a public record except when it
falls under one of the specific statutory exemptions.)
3 of 4 4/8/2015 11:53 AM
City of Northampton Mail-RE: 206NorthMainStreet-BuildingPermit https://mail.google.com/mail/u/0/?W=2&ik=39211afc3d&view pt&s...
Does the footing hole need to be inspected pouring the footing?
Thanks,
Joe
From: aimua @hotmail.com
To: cmiller @northamptonma.gov
Subject: RE: 206 North Main Street- Building Permit
Date: Wed, 1 Apr 2015 17:05:16 +0000
Thanks you Sir,
Date: Wed, 1 Apr 2015 12:42:28 -0400
Subject: Re: 206 North Main Street - Building Permit
From: cmiller @northamptonma.gov
To: aimua @hotmail.com
Hi,
You can start the foundation.
The deck beam and piers do not meet code. They are both undersized. The assumed
bearing capacity of the soil without being tested is 2000 Ibs per sqft.
I need a floor layout for the I-joist.
The LP tank will requires a 10' setback from the property line.
Chuck Miller
On Wed, Apr 1, 2015 at 9:17 AM, joseph aimua <aimua @hotmail.com> wrote:
Mr. Chuck Miller:
Assistant Building Commissioner
Dear Sir,
Attached files- Building plan and Framing , Floor joist and Beam design
calculation.
• Deck detail is included
• Windows in the basement are shown on foundation plan
Thanks you so much,
Joseph Aimua, P.E., S.E.
Joslad &Associates, P.C.
Date: Mon, 30 Mar 2015 12:32:53 -0400
Subject: Re: 206 North Main Street- Building Permit
From: cmiller @northamptonma.gov
2 of 4 4/8/2015 11:53 AM
City of Northampton Mail-RE: 206NorthMainStreet-BuildingPermit https://mail.google.com/mail/wu/,iui=2-&iic=syliiarc-ia&view=pracs...
�Z) - O�1
Charles Miller<cmiller @northamptonma.gov>
RE: 206 North Main Street - Building Permit
1 message
joseph aimua <aimua @hotmail.com> Wed, Apr 8, 2015 at 9:25 AM
To: Charles Miller <cmiller @northamptonma.gov>
Mr. Chuck Miller:
Assistant Building Commissioner
Good morning Sir.
Attached is the revised plan with the corrections as noted below.
1. Framing plan for the floors and beam/joist sizes
2. Deck beam changed from 2 - 2x10 to 3 -2x10
3. Design check for the deck 10" concrete pier has been done based on 3500 psf soil bearing capacity.
Based on the soil observation, the soil is mostly gravel with bearing capacity in the range of 3500 to
4000 psf.
4. The location of the Gas Tank is set at 12 feet from property line.
Thanks for you coorperation.
Joe Aimua
Date: Mon, 6 Apr 2015 09:27:53 -0400
Subject: Re: 206 North Main Street- Building Permit
From: cmiller @northamptonma.gov
To: aimua @hotmail.com
footing formed not poured,
walls formed not poured,
drainage in foundation coated before backfill,
any lingering paper work must be provided
rough after mechanical sign offs,
air sealing before insulation if permeable insulation,
insulation,
finish after mechanical and fire sign offs,
HERS Rating, signed thermal envelope checklist, duct blast testing results,
Note the HERS rater has required inspections also
Chuck Miller
On Mon, Apr 6, 2015 at 8:57 AM, joseph aimua <aimua @hotmail.com> wrote:
Mr. Chuck Miller:
Assistant Building Commissioner
Good morning Sir.
1 of 4 4/8/2015 11:53 AM