Loading...
22D-066 (6) 400991-YTG-G-0713 LEFT SIDE FRONT RIGHT SIDE Combustion Air Inlet Combustion Air Inlet Condensate Drain Gas Pipe (Downflow) Entry Gas Pipe _Condensate Drain Entry � (Downflow) Vent Outlet-1-0 Electrical Electrical Entry Entry Vent Outlet Condensate o Drain ® m 33 Condensate loci ® ® Drain r 23�CD r , Thermostat Wiring Thermostat-/ Wiring Optional Return Air 14" Cutout(Either side) A 29. �--- 9.5 56 i4-- 23.8" -D 3" Vent Outlet B Combustion B Air Inlet C .56" 56., 24.25" 20" 0 RETURN END SUPPLY END Cabinet&Duct Dimensions Cabinet Dimensions(Inches) Approximate Nominal Cabinet Operating Weights Models CFM(m3/min) Size A B C Lbs TG9S040A08MP11 800 A 141/2 133/8 11 3/4 113 TG9S060A10MP11 1000 A 141/2 133/8 11 3/4 118 TG9S060B12MP11 1200 B 171/2 163/8 131/4 122 TG9S080B12MP11 1200 B 171/2 163/8 143/4 126 TG9S080C16MP11 1600 C 21 197/8 ri2l 6 1/2 136 TG9S080C22MP11 2200 C 21 19 7/8 6 1/2 139 TG9S100C16MP11 1600 C 21 19 7/8 18 1/4 142 TG9S100C20MP11 2000 C 21 19 7/8 18 1/4 145 TG9S120D16MP11 1600 D 241/2 233/8 3/4 153 TG9S120D20MP11 2000 D 24 1/2 233/8 21 3/4 156 TG9S130D20MP11 2000 D 241/2 233/8 No Hole 160 Ratings&Physical 1 Electrical Data Input Output AFUE Air Temp. Max.Outlet Max Min.wire Size Blower Blower Total Unit Models % Rise Air Temp Size Over-Current Amps (awg)@ 75 ft MBH MBH °F °F HP Amps Protect one way TG9SO40A08MP11 40 38 95.5 30-60 160 1/3 4.8 11x8 15 8.0 14 TG9S060A10MP11 60 57 95.5 30-60 160 1/2 7.1 11x8 15 10.0 14 TG9S060B12MP11 60 57 95.5 30-60 160 1/2 7.1 11x8 15 10.0 14 TG9S080B12MP11 80 76 95.5 35-65 165 1/2 7.1 11x8 15 10.0 14 TG9S080C16MP11 80 76 95.5 35-65 165 3/4 8.8 11x10 15 11.5 14 TG9S080C22MP11 80 76 95.5 35-65 165 1 14.5 11x11 20 17.0 12 TG9S100C16MP11 100 95 95.5 35-65 165 3/4 8.8 11x10 15 11.5 14 TG9S100C20MP11 100 95 95.5 35-65 165 1 14.5 11x11 20 17.0 12 TG9S120D16MP11 120 114 95.5 40-70 170 3/4 8.8 11x10 15 11.5 14 TG9S120D20MP11 120 114 95.5 35-65 165 1 14.5 11x11 20 17.0 12 TG9S130D20MP11 130 123.5 95.5 45-75 175 1 14.5 11x11 20 17.0 12 Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes. The furnace shall be installed so that the electrical components are protected from water. 2 Johnson Controls Unitary Products 400991-YTG-G-0713 DESCRIPTION s These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in - upflow or horizontal applications and may be converted for downflow applications. Heating land Air Conditioning These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and TECHNICAL GUIDE are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and 95.5% AFUE SINGLE STAGE economical installation and operation. RESIDENTIAL GAS FURNACES These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic MULTI-POSITION combustion air and vent piping. MODELS: TG9S FEATURES NATURAL GAS Easily applied in upflow,horizontal left or right,or downflow 40-130 MBH INPUT installation with minimal conversion necessary. • Compact, easy to install, ideal height 33"tall cabinet. Blower-off delay for cooling SEER improvement. Easy access to controls to connect power/control wiring. Built-in, high level self diagnostics with fault code displays • standard on integrated control module for reliable opera- ; € tion. " Low unit amp requirement for easy replacement applica- 3 aitr� tion. Single wire twinning or staging feature available. All models are convertable to use propane (LP) gas. .r Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. 3 100% shut off main gas valve for extra safety. • 4 speed, direct drive PSC motor. • 24V,40 VA control transformer and blower relay supplied for add-on cooling. • Hi-tech tubular aluminized steel primary heat exchanger. • Secondary heat exchanger made of corrosion resistant stainless steel materials. III 9ESIGN • Timed on,adjustable off blower capability for maximum �f comfort. SB Blower door safety switch. Solid removable bottom panel allows easy conversion. S0 REGIS°RAC`° Airflow leakage less than 1%of nominal airflow at duct- `y,IC�WE0.NANr�r iO..WFUNFgt IS0 9001 • blaster conditions. GOOfI Housekee in Certified Quality No knockouts to deal with, making installation easier. eqa Promises p g 'pw Management System CFN(P RFNNpIFOER. " • Movable duct connector flanges for application flexibility. • Quiet inducer operation. Due to continuous product improvement,specifications Inducer rotates for easy conversion of venting options. are subject to change without notice. Fully supported blower assembly for easy access and Visit us on the web at www.york.com removal of blower. Additional rating information can be found at External air filters used for maximum flexibility in meeting www.ahridirectory.ora customers IAQ needs. • Protection included from air intake, exhaust vent, or con- WARRANTY SUMMARY densate blockage. A 20-year limited warranty on heat exchangers in residen- No special vent termination required. tial applications. 1/4 turn knobs provided for easy door removal. A 10-year warranty on the heat exchanger in commercial Internal condensate trap design (patent pending) provides applications. condensate management options and is self-priming to Standard 5-year limited Parts warranty. prevent nuisance problems. Extended lifetime heat exchanger and 10-year limited Venting applications-may be installed as either 2-pipe parts warranty when product is registered online (sealed combustion) or single-pipe vent(using indoor com- within 90 days of purchase for replacement or closing bustion air). for new home construction. See Limited Warranty certificate in Users Information Manual for details. FOR DISTRIBUTION USE ONLY- NOT TO BE USED AT POINT OF RETAIL SALE ommmommmmmw Entire House 1066 32666 10637 656 656 Other equip loads 0 0 Equip. @ 0.90 RSM 9573 Latent cooling 400 TOTALS 1066 32666 9973 656 656 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Mar-11 08:35:20 wrightsoftw Right-Suite®Universal 2015 15.0.07 RSU22550 Page 2 ACCK ...\Gateway\Documents\American Standard\Thayer.rup Calc=MJ8 Front Door faces: N Load Short Form Job: Date: Entire House By: Rock Valley HVAC Project Information For: Dougas Thayer 89 Florence Rd, Northampton, MA 01060 Design Information Htg Clg Infiltration Outside db (°F) -2 85 Method Simplified Inside db(°F) 72 70 Construction quality Tight Design TD (°F) 74 15 Fireplaces 0 Daily range - M Inside humidity (%) 30 50 Moisture difference(gr/lb) 32 38 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 656 cfm Actual air flow 656 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.062 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.96 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Kitchen 209 5580 1777 112 110 L. Room 147 5204 1760 105 109 Dining Rm. 154 4739 1682 95 104 Bath 1 46 1434 424 29 26 Bed 1 147 4597 1478 92 91 Bed 2 154 4132 1400 83 86 Bed 3 160 5480 1673 110 103 Bath 2 49 1500 443 30 27 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Mar-11 08:35:20 .` + WrightSOft' Right-Suite®Universal 2015 15.0.07 RSU22550 Page 1 XCK ...\Gateway\Documents\American Standard\Thayerrup Calc=MJ8 Front Door faces: N 8 , �'t, r %4 G/PGO �) Z, //\ lAe Iq F � h 1 1,w � l � 0 r, fe AW tz gy/o ti 15e-,,A INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yes❑ No❑ If you have checked Yes,indicate the ty a of coverage by checking the appropriate box below: A liability nsurance policy Other type of indemnity ❑ Bond ❑ tY p Y OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box[],I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation:YES NO Progress Inspections Date Comments Final Inspection Date Comments Type of License: By ❑ Master r Title ❑ Master-Restricted / City/Town ❑Journeyperson j Signature of Licensee Permit# 6 ❑Journeyperson-Restricted License Number: r6 2 Fee$ ❑ Check at www.mass.gov/dpl Inspector Signature of Permit Approval uommonweann or iviassacnusetts Sheet Metal Permit Date: ,3 /—OZ Permit# ted Job Cost: $ %C' , �' ``' Permit Fee: $ S� Pla ubmitted: YES v--'NO Plans Reviewed: YES NO _> "Bu d ss License # Applicant License # Ii cV z (. Bu ss Information: Property Owner/Job Location Information: Uj L.0 .o Na t= (2�z �< V(` 1C ` y y� Name: l� .� 2� o l trect 7 Street: City/Town: , t r 6AlIq c,<e rife) City/Town: Telephone: >_7 ```1 Telephone:(gl�) s 3� – e--V 7f.' Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 M- license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. over 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work:�''� Renovation: HVAC Metal Watershed Roofing Kitchen Exhaust System Metal Chimney /Vents Air Balancing Provide detailed description of work to be done: e � � File#SM-2015-0036 APPLICANT/CONTACT PERSON ROCK VALLEY HVAC ADDRESS/PHONE 7 APPLEWOOD LN (413)535-7804 PROPERTY LOCATION 89 FLORENCE RD MAP 22D PARCEL 066 001 ZONE URA(100)/WSP(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Buildina Permit Filled out Fee Paid Typeof Construction: INSTALL COMPLETE DUCT SYSTEM New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included• Owner/Statement or License 2626 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Pe 1 ree n Permit DPW Storm Water Management S natu B in f icial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information. 89 FLORENCE RD SM-2015-0036 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 2705 Map: 22D B,iock: 466 SHEETMETAL PERMIT Lot: 001 Permit: SHEETMETAL _ Category::SHEETMETAL — Permit# SM-2015-0036 PERMISSION IS HEREB Y GRANTED TO: Project# -JS-2015-0009'38 P t. Contractor: License: Expires: Es Cost: $10,040.04_.j — Fee Charged:$25.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2016 Balance Due:$.00 Owner: THAYER DOUGLAS #of Fixtures _ _ Applicant: ROCK VALLEY HVAC D if gSafe#` _ AT. 89 FLORENCE RD lUseGroup' PonstClass ISSUED ON. 18-Mar-2015 AMENDED ON: EXPIRES ON. TO PERFORM THE FOLLOWING WORK: INSTALL COMPLETE DUCT SYSTEM THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2015-004335 17-Mar-15 565 $25.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck @ northamptonma.gov GeoTMSO 2015 Des Lauriers Municipal Solutions,Inc.