Loading...
17C-072 (5) Location..................................................................... PermitNo. ................................................................. Application for other than a Dwelling PermitGranted........................................... 19......... To .............................................................................. 4: NOTE:IN ORDER THAT THIS APPLICATION MAY BE ACCEPTED,THE DATA CALLED FOR BELOW MUST BE SO SET FORTH THAT WE CAN DETERMINE FROM THE APPLICATION AND THE ACCOMPANYING PLANS WHAT THE EXISTING CONDITIONS ARE AND _ WHAT THE FUTURE CONDITIONS WILL BE. ' ) 7C` � ¢= Plans,in duplicate,mustbe filed with this application before a permit will be granted,one of which,upon issuance of the permit shall be kept at the site during the progress of the work. New............. .� /n Addition........❑ No.................-D, Zone.11.1`..t,7..(�...., Type..................., Map....17.G....., Parcel...�.�.......... Alterations ....❑ Repair............❑ Demolition.... _ a CITY OF NORTHAMPTON Demolition e MASSACHUSETTS Application for other than a Dwelling Permit (To be filled out in ink OR on a typewriter) Date.......04Y.......7.y................... 19 9.J.. To the Building Inspector: Application for a permit is hereby made a r O t the�llowing-- L 1. Location, Street and No.. St!�,T(/.�� ../.�!.er........./..!!G..!f 7. !1►!!� Q. ........................................ 2. Nearest cross street.... ....� 1... Sf�' . ..J...... ...................................................... .... . Lot No.................... ,�� j 3. Owner's name......1..(!1.1t '!1.1.N....1r...../...[eo.1l.►"....................... Address ,�1� �'�!�6.s.4�'!9(.��'......................... 4. Architect's name...............?Ymt................................................ Address ............................................................. 5. Builder's name ............................................................................ Address .................. ..... ....e........................... 6. Use of building, Present..................................... Proposed ......S�4Y.1 1�.... �................................ 7. Building fronts on how many Streets?............jo.e............................................................................................... 8. Is building in fire district?...................lY 4.................................................................................................y........... 9. Size of building,Width in ft. ... .....11....�............, Length in ft.....7..!�................. Height in ft...... �fD................� 10. Distance of building from Street Line..44?..., left lot line.�1/ right lot line.I.75 rear lot line 11. Type of construction(check one): i-A.......... 1-B .......... 1---C .......... II.......... III.......... IV .......... V .......... Stories B 1 2 3 4 5 6 7 Roof Story heights in ft. Thickn's of walls in ins. Material of walls ` Material of floor/roof e Design live load Design dead load Occupancy or Use No.of persons/families Q 1 ayt' n No.of stairs e 12. Soil under footing is........ ..e, .:..............p............................. 13. Depth of footing below grade...1 �!l ,l.f........... Or. Will Iles be used?....,/V*0,,,,,,,,,,,,,,,,,,,,,,, 14. Area of entire building(Present plus new) ............... . QO.............................................. . ................. sq.ft. 15. Type of roof-flat....................... pitched.....X..... ... Material of roof covering......... �........................... 16. No.of elevators.....0...... Method of Cleating.&M2. System ................................. Fuel ................................. 17. Are live loads noted on drawings? ..1.'s....... Are all other structural conditions noted on drawings?A. � ......... 18. Building(will be)(is)equipped with sprinklers?.....M...................... With sprinkler alarm?....A.................. 19. Is building to�be-used as a factory,workshop or mercantile or other establishment employing 10 or more persons? ....................1.!.:!�........................................................................................................................................................ 20. Is building to be used as an office building,dormitory,hotel,family hotel,apartment or boarding house,lodging house or tenement house having 8 or more r�s above the second story? ..........A......................................... 21. How many exits(per floor)to street? ......../...Ws. ............................................. ................................................... 22. Is building a"Place of assembly"as defined by, General Laws? ... +� ...............e.................................. llt............... Building �.............. 23. Will building conform to the General Laws. .......... g and Zoning Ordinances. .......l.1............ 24. If a garage,distance from nearest building? .........�a°t�0x......3.7........................................................................... 25. If an addition,alteration or demolition,when was building erected?.........„/..!7.................................................... 26. Estimated costs:- The undersigned certifies that the above statements are true to the best / General$...... ................ Hof his/her knowledge and belief. Plumbing......................................... � -. ............. ...... ......................................... Gas Piping Signature of owner,architect or engineer Sprinklers........................................ WRITTEN DISCRIPTION OF WORK TO BE DONE Heating.. (Use blank half of reverse side,if necessary) Electric.K4Ir�N..Ci (.Yt..Sy�'.7.1'r°it)f G5 ............................................................................................................... Other............................................... ............................................................................................................... Total$.....1��fj� ....................................................................................................... ..... J PRINT SHOP •X L } f ��<.. Y �I pi 3f1 RETURN IN 6 DAYS DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ' Municipal Building Northampton, Mass. 01060 Ncn-rm Named 25 Garfield Axe. NordwTtcri, 1A 01060 July 9,1991 City of Northampton Office of the Building Inspector Northampton, MA 01060 Re: Building Permit 17C 72 Gentlemen: Please extend the building permit for an additiona; six(6) months for the three car garage located at 25 Garfield Avenue. Sincerely, Norman Menard � L- Notary Date My commission expires December 5,1991 4" SLAB ON GRADE i us.s,•-6/5 W-Tt FA8F"C n ---SAIIQ r5 OR CONS'IR. JM Z u: - A7 14'-O'C�"„ O 0 AL 7 - - - — - -- _ 0U7 -0 OJ? OF FoUt:DA'10N FOUNDATION PLkN CL"r-Rf snap OUTDO C'IAD ANO:.z OROJ--SLOPE ro M QN rcaa>7t aat�F.D ar+c,F 90#T OARS 0 2r C/OiiS �- D OWAUL PAYEE I t� r ARCH TO PANM DETAIL PA.M ANCHORS SIDENAi•I ELEVATION h: NS.. Ma. TENSILE o 111! t it BOLTS. 5/16"-18 x 3/4'. GRADE 2 SAE i :t it it I A DESIGN DATA 19—APEK- 25 psl REARWALL ELEVATION"T W.w.;:. D ESIGN L'ATA : CONCRETE S-,vF-NCTH AT 28 DAYS TO BE 3000 PS. 2. RONFORCING STEEL TO BE DEFORMED BARS. GRADE 50. 0 24' c,c I SAFE S041- BEARING PRESSURE WAS ASSUMED TO BE 350C PSF. 4. ALL MATERIALS SHALL CONFORM TO THE APPROPRiAit AS7V SPECIRCATIONS- S7,RRUPS a 118- o/'c --ICA SECTION A-A 7 42'-8- OJT 70 OUT OF FWNDA7ON 22' REV. DATE I DESCIPEPMON BY j AF.P. W.WY. 12' -J� I-NO.4 BARS (-'O,.,.'T. 4' is' PIONEER BTdTDLN, GS --7 PIONEER 21 GENERAL ARRANGEMENT CHECKED. CL*W. N0-3 STIRRUPS 0 le o/c P-Rl4UTO 4 MR. MENORD FLORENCE. MASS. SECTION B—B t SCALl'-- wXXI ma COWMACT Na SHEET XQ N.T.S. S-35-1115 14 MENORD.DWG 1 0 F MAR 90 35"-b 0,J7 TO Oi:T ✓ S7- AR--H;--. GENERAL NOTES DOOR I. ALL MATERIALS AND WORKMANSHIP SHA!_L. CONFORU W7-i vUli ING THE REQUIREMENTS OF THE BOCA BASIC NADONAL � BUILDING CODE. _�. ._-_----------- ------ "�_.__ 2. IT IS THE OWNER'S RESPONSIBILITY TO MAKE CERTAIN THAT NO LOADS OTHER THAN THOSE GIVEN UNDER 'DESIGN DATA' ARE IMPOSED ON THE STRUCTURE. 3 SOLUTIONNDONLY. CHANGES MAY BE NECESSARY SUGGESTED TO LOCAL BUILDING REGULATIONS. -Y THE FOUNDATION SHALL BE FOUNDED ON NATURAL UND1STliRBED o I SOIL CAPABLE OF SAFELY SUSTAINING 3500 PSF. -�— II 5. SLAB ON GRADE SHALL BE PLACED ON SOIL CAPABLE OF _ SUSTAINING 500 PSF. WITHOUT SETTLEMENT. 6. SPECIFIC NOTES AND DETAILS SHOWN ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THE BUILDING MANUAL SUPPLIED. i It i -A ARCH DATA i 2r I FRONTWAL L ELEVATION f I 35"-4" OUT TO OUT OF STEEL ACHES } k BUILDING T--- �— STEEL-• .030/.038 GALVALUME SHEET STEEL, STRUCTURAL WALITY. 1 � � o .+� ►gyp � O �• M a O 5 > o I Zoning C- _ Miscellaneous Additions,Repairs,Alterations,etc. Tel.No. Alterations a "I"..NORTHAMPTON, MASS. 19 Additions APPLIC ATION FOR PERMIT TO ALTER Repair Garage ,. r ..rr: p,A; Lot No. Location � �/ ,�r.?�- } Owner's name �/ Yrc� � r�1�da�! a�/,.r� Address -}' 2 ". .i�l'�� e_ c 3. Builder's name Address Mass.Construction Supervisor's License No. Expiration Date_ 4. Addition 5. Alteration 6. New Porch 7. Is existing building to be demolished? " 8. Repair after the fire }Garage % f ... =j i, �,Ys - �.1!No.of cars Size 10. Method of heating Distance to lot lines 12. Type of roof — 13. Siding house VEstimated cost:- The undersigned certifies that the above statements are true to the best of his, h( knowledge and belief. Signature of responsible applicant Remarks �, -PB�IyNyTnPSHf lw� ". 1 ?e- 7a Date Filed f,,ile No . ZONING PERMIT APPLICATION (510 . 2 ) 1 . Name of Applicant: Address Telephone : 91 t - n /t 2 Owner of Pro],-)nr,--y: r 7 A d dr,e s,s _TelephorL 3 Status of Appi.icant: ,-,--o w I I C-1 r --contract Purchase--r L c s,,;e.o other. (explain:___ 4 Parcel Identification: Zoning Map t.,)heetP Parc,,:,:l,� Zoning District (s) (include o Street ileq.ii red 5 . F'Xistilig b Zoning -R�)0 q� -e—d Use of Structure/Property (if project !.!:i only interior work, skip to #6) b 'e'q Building height -%Bldg. Coverage (Poo tpri n t) Setbac)(s front side rcar Frontage Floor Area Ratio -%-Open Space (Lot area minus building :-j.nd pa.rki.rig) Parking Spaces Loading Signs Fill. (volume, & location) Narrative Description of Proposed Work/Project: (Use additional sheets necessary) 4 7 . Attached Plans : Sketch Plan Site Plan B . Certification: I hereby cer-t-ify that the information contained herein is true and accurate to the best of my knowledge . Date: Applicant I s S ignatu're: 161rj/j/-rt,Sx- THIS SECTION FOR OFFICIAL USE ONLY: �enied pproved as presentcd/based on inf ormation preseqte.d as presented. Reason for Denial .- A�— I Signattfd-'o Iui.-r'cltn nspe Date 'n7 4, Y 1 �C o WO o � d a tz c <) n c. 3 o ''d C M O O o z tri c` Zoning U Miscellaneous Additions,Repairs,Alterations,etc. Tel.No. Alterations a NORTHAMPTON, MASS. 19 Additions Repair APPLICATION FOR PERMIT TO ALTER Garage 1. Location S CA S � ' �'�'? /I Ll Lot No. 2. Owner's name �''`''�'Le d� "'v�- Address 3. Builder's name Address Mass.Construction Supervisor's License No. Expiration Date 4. Addition 5. Alteration 6. New Porch 7. Is existing building to be demolished? 8. Repair after the fire r � ' 9. Garage &5 No.of cars Size ZS X ZS 10. Method of heating 11. Distance to lot lines 12. Type of roof 13. Siding house 14. Estimated cost:- 71, v The undersigned certifies that the above statements are true to the best of his, her knowledge and belief. Signature of responsible applicant Remarks— PRINL+SH H P N City of Northampton REQUIRED INSPECTIONS 1 . Footings and Walls ,. 2 . Structural Components in BUILDING DEPARTMENT �s Place 3 . Complete Building No. -262- Office of the Building Inspector Date MW 10, 1990 19 BUI DING P RMIT THIS MAY CERTIFY THAT Ncmmz Na-md Insp. on Site — Foundations has permission to 25x25 ganne - tlree cis :3s�2� Insp. of Plumbing — Rough situated on 25 GaHield Awe. Insp. of Plumbing — Finish provided that the person accepting this permit shall in every re- Insp. of Wiring — Rough spect conform to the terms of the application on file in this office, and to the provisions of the Statutes and the Ordinances relating Insp. of Wiring — Finish to the Construction, Maintenance and Inspection of Buildings in Insp. of Health (Septic Tanks) the City of Northampton. Any violation of any of the terms above noted is an immediate revocation of this permit. Expires six Building Insp. — Rough months from date. Building Insp. — Finish Note: A certificate of occupancy will be issued by this office upon return of this card signed by the Plumbing, Wiring and Building Smoke Detectors (Fire Dept.) Inspectors. Gas Inspection THIS CARD MUST BE DISPLAYED IN A CONSPICU US PL AC E ON THE PREMISES Certificate of Occupancy Building Inspector PAINT R P