Loading...
07-027 (3) Page Two UNIT & MATERIALS SPECIFICATION IN DETAIL 12. PLUMBING: (1 ) Stainless Steel sink - 32" x 21 " double compartment with single lever mixer, swing faucet, spray and strainer; (2) Lavatory - in white (3) Water closet in white with seat; (4) Bathtub - Owens Corning fiberglass with integral surround in white with faucets, shower, waste &overflow, & tub enclosure; (5) Shower - Owens Corning fiberglass with faucet in white. Plumbing fixtures American Standard or equal ; (6) Other plumbing as shown, 13. APPLIANCES: (1 ) Range 30" Slide-In: (2) Hood, Light & Fan; (3) Disposal - 1/3 horsepower; continuous speed; (4) Dishwasher*; (5) 16 Cu,Ft. Refrigerator with double door*; (6) Washer*; (7) Dryer*; NOTE: These appliances in Avocado or Harvest Gold, General Electric or equal . Items #6 & 7 - WHITE Only. 14. HEATING: Baseboard Electric complying with National Electric Manufacturers Assn. (NEMA) & Underwriters ' laboratories, Inc. (UL) complete with a full length thermal disconnect and calrod element as manufactured by Berko Electric Manufacturing Corp. or equal . Each room thermostatically controlled with a double pole thermostat. Optional - oil fired. cast iron boiler with hot water baseboard heat. 15. ELECTRIC WIRING & FIXTURES: (1 ) All switches (silent type) G.E. or equal convenience outlets and light fixtures; (2) All rough wiring including the main panel ; (3) Nutone or equal door chimes; (4) Nutone or equal smoke detector/alarm system, 16. INSULATION: Full Thick (6-1/2")(R-22) in ceilings, semi-thick (3-1/2")(R-11 ) in walls & under first floor. 17, ROUGH HARDWARC: ( 1 ) Nails; of the proper size and specifications for a complete job. Galvanized nails for all exterior exposed nailing. Galvanized nailing for roofing. 18. FINISH HARDWARE: (1 ) Locks - main entrance lockeet as manufactured by Weiser Company or equal . Inside doors with interior cylindrical lockets and latch sets; (2) Other - all finish hardware for a complete job. 19, EXTERIOR FINISH: (1 ) Prime painted, except for Cedar Shingles which are natural , 20. FLOORING: (1 ) Continuous filament nylon carpet with padding in bedrooms, hall , living room, and formal dining room; (2) Vinyl inlaid in kitchen and bathroom over 3/8" ply- wood underlayment grade, 21 . MEDICINE CABINETS: Bath #1 - large double sliding mirror door with light above, Bath #2 - single door cabinet with light fixture above. Grote or equal , 22. These specifications are intended to include labor in manufacturing of the house and materials for the house above the foundation sill plate. Purchaser to provide two (2) mechanics to assist in the erection of the house onto the foundation. Labor and ma- terials for the foundation, sill plate, stairway erection, hook--up or electrical plumb- ing and/or labor for field completion and items related thereto are not included. 23. Specification, sub,ject. to change without notice. For split-entry, Cape models and 26 ' wide Uni--Structur(­, and at.t:ached garages, refer to specification sheets !>o noted. Optional M CONTINENTAL HOMES Route 3 South, Nashua, New Hampshire 03060 Telephone (603) 888-2191 CONTINENTAL UNI-STRUCTURE: UN11 & MATERIAL SPECIFICATION IN DETAIL Effective MARCH '15, 1976 1 . EXTERIOR WALLS: (1 ) Framing - Western Hemlock or Western Spruce construction & standard (factory option) stud size 2x4, S4S, spaced 16" O.C. ; (2) Sheathing 1/2" x 4' x 8' -C.D. exterior glue, 32/16 plywood conforming to U.S. Product Standard, P.S. 1-66; (3) Sidings: Masonite X-90 9" or 12". Optional extra - Cedar Shingles, Masonite X-90 6" Masonite Color-Lok 9" in white, green or bronze. All siding shall be deleted if requested. All gable end sidings are shipped loose for field application. 2. FLOOR FRAMING & SUBFLOOR: (1 ) Girders - Western Hemlock or Western Spruce composed of two layers of 3/8" plywood, 2-2 x 8 S4S & 2-2 x 6 S4S; (2) Floor joists 2x8 Western Hemlock or Western Spruce S4S, 16" O.C. ; (3) Subflooring 5/8" x 4' x 8' Tongue and Groove with exterior glue, underlayment 42/20 plywood. 3. PARTITION FRAMING: (1 ) Studs - Western Hemlock or Western Spruce construction & standard. 2x4, 16" O.C. ; (2) Shoe - 2x4 S4S; (3) Plates doubled; (4) Headers - see plans. 4. ROOF: (1 ) Sheathing 112" x 4' x 8' C.D. exterior glue plywood 32/16 conforming to U.S. Product Standard, P.S. 1-66; (2) Shingles - Asphalt 240 lb. Sealtab, size 12' x 36 WUnderlayyrent - 15 lb, Aspphalt felt, doubled; (4) Roof Trusses - 24" O.C. (Roof ch - 3/1Z - optional 4 5/12) . 5. INTERIOR WALLS & CE=ILINGS: (1 ) Gypsum Board - 1/2", walls & ceilings (factory finished); (2) Paneling - optional over 112" Gypsum Board; (3) Wall finish painted - two coats homogenized latex as manufactured by Glidden Company or equal ; (4) Bathroom, Kitchen & Hall walls — vinyl wall covering; (5) Kitchen Accent wall - Wainscotting with Paneling - wallpaper above, 6, ADHESIVE: B.F. Goodrich, PL400 Adhesive or equal applied to: (1 ) Plywood on exterior walls; (2) Subfloor; (3) Gypsum Board; (4) Paneling. 7. DOORS WINDOWS & MILLWORK: (1 ) Door Mts - 2-1/4" casing, jamb, and trimming are pre-. finisAed. Doors flush prefinished; Windows - Crestline prefinished with wood storm sash and half screens; (3) Base - l member, prefinished; (4) Closet rods- wood or metal (factory option) . 8. ENTRANCE DOORS & EXTERIOR MILLWORK: (1 ) Entrance doors - Pease Everstrait or equal ; (2) Ventilation - gables, 8 mesh galvanized screen behind, see plans; (3) Exterior millwork, Western Pine. 9. CABINETS & INTERIOR DETAIL: (1 ) Cabinets - Triangle Pacific prefinished; (2) Counter top post formed Formica; (3) Lavinette, main bath - prefinished with lavatory. Other millwork as per detail . 10, STAIRWAYS: Basement Stairs where shown, 11 , BATH ACCESSORIES: (1 ) Four (4) per full bath; (2) Four (4) per half bath. Continental Homes Division of Weil-McLain Co. Inc . Plants in Boones Mill, Virginia. Malden. Missouri: Nashua, New Hampshire * Optional CITY OF NORTHAMPTON ZONING PERMIT APPLICATION �,' j � '� �1 Tax Map No. a Lot / Zoning Ordinance Section 10.2 Rece ved: File No. Plan File Owner Applicant /2 G�/ T��L ��4�rr� Address `��`i ��1z'� X 2V /V' 70AI Address Telephone_ ✓��`� �3 Telephone This section is to be filled out in accordance with the "Table of Dimensional and Density Regulations: (Z.O. ARTICLE VI) Zoning Use Lot Front Depth Setbacks Max. Bid. Min. Op. District Area Width Front Side Rear Cover Space Past Existing %0 75 0 — loo Present Proposed % % Mark the appropriate box to indicate the use of the parcel: ❑ Non-Conforming Lot and/or Structure. Specify Residential XSingle Family Unit ❑Multi-Family ❑ Duplex ❑ Other ❑ Business ❑ Individual ❑ Institutional ❑ Subdivision ❑ Regular ❑ P.U.D. ❑ Cluster ❑ Other ❑ Subdivision with "Approval-Not-Required"-Stamp: ❑ Planning Board Approval: ❑ Zoning Board Approval (Special Permit 10.9: Variance) ❑ City Council (Special Exception S. 10.10) Watershed Protection District Overlay: (Z.O. Sect. XIV) ;<Yes ❑ No Parking Space Requirements: (Z.O. Sect. 8.1) Required Proposed -� Loading Space Requirements: (Z.O. Sect. 8.2) Required Proposed Signs: (Z.O. Art. VII) ❑ Yes �WNo Environmental Performance Standards: (Z.O. Art. XI 1) >Yes ❑ No Plot Plan ❑ Yes X No Site Plan ❑ Yes D(No (S. 10.2) (S. 10.2 and 10.11 _ Waiver Granted: Date ❑ This section for OFFICIAL use only: ❑ Approval as presented: ❑ Modifications necessary for approval: ❑ Return: (More information needed) ❑ Denial: Reasons: 177 Signature Signature of Appl,i_qdnt Date Sig uup—of Admin. Officer Date THE PRINTING t%VS o� o Crzt of Wort uni jton � $ �lassach�isetts =— t i 1j = s Offire of tht �nsptrtor of 'Puilbings W 212 Main Street•Municipal Building = �7 Northampton, Mass. 01060 V CERTIFICATE OF OCCUPANCY July 20, 1977 Page No. 2 Plot Building (Name) Forth Farms Road Address Same Owner vlalter Japer Address 5Y9 N. Farms Road Applicant Same Address Use: 1st bne—family -rAcaidw_nt P- Occupancy l„a1+_tez laser 2nd Occupancy 3rd Occupancy 4th Occupancy Zone District RR Required Inspections: New Building X Existing Building- Elevator ? Electrical - r Plumbing Fire Building 'l Other r✓ -A,`fA. C,,A Inspector of Buildings ` TILE wR�55 ZONING • IX. SITE OR PLOT r=�i •r MOMMUMMOMMMUM Was .i! NM+�I ■ ��ui�itii�•�is�i■i::�Na::wr:�iii:°iiii • uriZ°ia�S::Nii:r ior��� � �i2�::•rrNi:i :� : y■{*��'y.`.; as :.e qq.- �6 ' \ ! ■ a�n�1 a "Wage • N • . •�Mi�••��lN►��■■a•rrf iar•� • a■I aIN 4l:g u•N•ii#N.aU.a•.■a N::•NNuNu•aYa•N#!N N" ■■■■om" Na: a: N■ 8:4: lunges ■:■NaraNNlONNNa Ns \ i �aN NaaNH•ala.■N#■••N•■a• i a..*� : .C::q:S.:'::�.:::�C a( '/lf_i N • N � r •N:i■N�NNa N,NaNNMoN.■ me � .�r � • :9 '�•� • a ■ NNS rNNNNU uu i p • NlNa■Na aNa. •rN■N pry • .a■ sN:jiNauw3N.::su■aaa����yr r■ •uruN oou • • i � FREM a:laaa:ra■u N■N NNar- :rNNlN■ a N ■�trw•gNq:a:• • ■!■l:a:smarm ' aliU N ■\\alas• oN! as N 9�•• •i NNr:NY 0 MC: bir .r �« 4 • :: : •� u •a �•::• ll.1N ■ ■ u a OWN �r ,•:,g! N N•:u:::: uunlumusl 39-Hum. Irin Nao m .a �r �� s HO wuitis■ iir�i•a! .01� « :s 0.■ :1.1••11:: Oaaapaa ' - ay.lo••aN.aua f ; i Q :■:i:l::::i:•N•�•ri r a i::u::re•• al :am i ia•ial : :•M ii$�:•uagI s :, I Non PJ1 o , g M NOTES and Data — (For department use) IV. IDENTIFICATION — To be completed by all applicants Name Mailing address - .\rnnhcr, street, rih, rrrnl SIafc� ZIP code T(e/l.pNp. 1. Owner or f+L.��TZ- ���'�[.� ✓�/ /v �i"7��/� /C.C� /!/��/i�q/�p��l/ �� ��9 U �/ G��� Lessee �/ / A/ • Bui lder's L. o 17 oge,&- L---?,/�,.V No. Contractor 3. /�/ i Y JS/✓�� 00 Architect or - +tO'T7 A/` L- Engineer I hereby certify that the proposed work is authorized by the owner of record and that I have been authorized by the owner to make this application as his authorized agent and we agree to conform to all applicable laws of this jurisdiction. Signature of applicant Address Application date le�,ew-r g12 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Required Check Plan Review Date Plans B Date Plans B Notes 9 Fee Started y Approved y BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Date Date Permit or Approval Check Obtai ed Number By Permit or Approval Check Obtained Number By BOILER PLUMBING _ CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit number 154 Building Permit issued May 121, 197 _ Building Permit Fee $ !78.oo Certificate of Occupancy S Approved by Drain Tile Plan Review Fee S- TNSPP .TOR OF BUILDINGS TITLE City of Nort4alliptan 41 ,� � �TilsssMChllsetfs O##ice of theJns}rertur ofuilDings APPLICATION FOR ZONING PERMIT AND Page Plot�_ BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, 111, IV, and IX. p .�uV //�� ZONING y� 1• AT (LOCATION) i' Qa7lt M em4 RD DISTRICT ',` LOCATION �+(NO.) (STREET) OF BETWEEN l 0L) it WA- AND —1-6LOAj t° l i1✓C BUILDING (CROSS STREET) (t'Rt11-9+QEt'r) LOT SUBDIVISION LOT _BLOCK SIZE 31 Vf 11. TYPE AND COST OF BUILDING — All applicants complete Parts A — D M A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use M 1 New building Residential Nonresidential 2 Addition(1/ residential, enter number f 120 One family 18 ❑ Amusement, recreational of new housing units added, if any, in Part D, 13) 13 ❑ Two or more family — Enter 19 ❑ Church, other religious \ number of units— — — — --jo. 20 ❑ Industrial 3 ❑ Alteration (See 2 above) 14 ❑ Transient hotel, motel, 21 ❑ parking garage 4 ❑ Repair, replacement or dormitory — Enter number 5 ❑ Wrecking (If multifamily residential, of units ------- — 22 Service station, repair garage enter number of units in building in 15 ❑ Garage 23 ❑ Hospital, institutional Part D, 13) ❑ r' 16 ❑ Carport 24 Office, bank, professional 6 ❑ Moving (relocation) Public utility 17 ❑ Other — Specify 25 ❑ y 7 ❑ Foundation only 26 ❑ School, library, other educational r-' B. OWNERSHIP 27 ❑ Stores, mercantile 8 K Private (individual, corporation, 28 ❑ Tanks, towers nonprofit institution, etc.) 29❑ Other — Specify 9 ❑ Public (Federal, State, or local government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., food processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement•,,,,,•,,,....., c�J�S� L� school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical..................... b. Plumbing ..................... c. Heating, air conditioning.......... d. Other(elevator, etc.)............. 11. TOTAL COST OF IMPROVEMENT $ S a -ov me III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. y D E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS R1 30❑Masonry (wall bearing) 40 ❑ Public or private company 48• Number of stories.............. 31 � Wood frame 41 ® Private (septic tank, etc.) 49• Total square feet of floor area, all floors, based on exterior 32❑ Structural steel dimensions ..................... pt©GJ 33 ❑ Reinforced concrete H. TYPE OF WATER SUPPLY 34 ❑ Other — Specify 42 ❑ Public or private company 50. Total land ores, sq. ft. ........... 35a 3�p 43 Private (well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... O 35 ❑ Gas Will there be central air 52. Outdoors........................ 36 ® Oil conditioning? L. RESIDENTIAL BUILDINGS ONLY 37 ❑ Electricity 44 ❑ Yes 45 [g No 53. Number of bedrooms.............. .g 38 ❑ Coal 39 ❑ Other — Specify Will there be an elevator? 54. Number of Full.......... 46 ❑ Yes 47 LZ No bathrooms Partial....... I hereby certify that the proposed work is autorfzed by the over of ..record and I have been authorized by the owner to make this application as his authorized agent. SIGNATURE OF AGENT ADDRESS (NUMBER) (STREET) (CITY) APPROVED BY ? TITLE F DATE 19 DEPT. PILE COPY � Zo Q BUILDING is PERMIT VALIDATION DATE May 12. 19 77 PERMIT NO. 154 APPLICANT_ Walter Jager ADDRESS 9 N_ Farms 'j OA N0.) (STREET) (CONTR'S LICENSE) NUMBER OF PERMIT TO New QnA� fi�atf rP.CI[3eYAt!P_ ) STORY Regidenne DWELLING UNITS (TYPE OF IMPROVE ENT) N0. - (PROPOSED USE) AT (LOCATION) North Farms Road DINING RR DISTRICT (N0.) (STREET) a BETWEEN _ (in I III fxy �[,9:V AND Town Tine 'D X%ROSS STREET) (CROSS STREET) w IL SUBDIVISION LOT BLOCK SIZE 31 acres a U O BUILDING IS TO BE FT. WIDE BY FT. LONG BY FT. IN HEIGHT AND SHALL CONFORM IN CONSTRUCTION m O Z TO TYPE USE GROUP BASEMENT WALLS OR FOUNDATION E FY (TYPE) a REMARKS: NAw 0nA-.fa.mj3y rRAiC]ennn AREA OR PERMIT VOLUME (CUBIC/SQUARE FEET) ESTIMATED COST $ 25.,5OO.00 FEE $— 78.0O OWNER Val_'(,er .Tq.ger ADDRESS 549 N. F BUILDI D P . Farms Rr�., Northamp#,�ln BY (Affidavit on reverse side of application to be completed by au orized agent of owner)