Loading...
24C-042 (5) KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 12, 2001 Northampton High School KB # 96079 Page 6 of 6 LOUNGE NO. 0407 (CONT'D) 4. Install hazard tape (black&yellow stripe.) on edge of low duct. �Y 5. Patch wall behind door to lounge bathroom(no fixtures). Install carpet in lounge. , t. BOYS HANDICAP TOILET NO. 0405 1. Clean toilet partition. - 2. Remove foreign substance from handicap grab bar. r` 3. Clean kick plate. GIRLS41ANDICAP TOILET NO. 0404 i 1. Patch abandoned pipe hole on east wall. 2. Install blank on abandoned 4" square electrical box. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 12, 2001 Northampton High School KB #96079 Page 5 of 6 ART 1 NO. 3204 1. Patch to match damaged wall at north side of counter. 2. Replace water stained ceiling pad at south west corner. '3. Re-patch hole in wall inside open cabinet at east wall. 4. Counter sink screw holes and plug in open cabinet shelving unit. 5. Re-place damaged ceiling pads in sink alcove. 6. Replace existing plug and install GFI plug on counter wall near sink. ART YNO. 3211 1. Patch to match holes in wall over 3211B Door. y 2. Clean or replace all ceiling pads in the vicinity of the sprinkler heads due to dirty fingerprints on pads. joint at ceiling 3. Install ceiling grid in� ad at duct.p 4. Remove chalk line over north wall cabinets. "5. Caulk around 5"blank cover at skylight. 6. Counter sink screw head holes and install plug at all open shelving cabinet units. AREA OF REFUGE NO.3213 1. Correct or replace ceiling pad at sprinkler head. 2. Replace damaged ceiling pad at smoke detector. LOUNGE NO. 0407 Remove brick dust from south wall. 2. Build soffit around duct and complete ceiling. 3. Caulk around duct at east wall. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508) 520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 12, 2001 Northampton High School KB #96079 Page 4 of 6 AUDITORIUM NO. 1210 (REAR) 1. Re-install ceiling pads. 2. Install railings at handicap sections. L/ 3. Remove caulk or cement from inside north wall grill. L/ 4. Restain wood trim at Door Head No. 1210E. ART ROOM 2 NO. 3210 V/ 1. Reinstall ceiling pads. l� 2. Fire caulk around duct to spray booth at ceiling pad. 3. Correct or Replace ceiling pads at 7 sprinkler heads - (pad damaged or does not cover escutcheon). 4. Clean or replace ceiling pads at sprinkler head areas due to obvious fingerprints. 5. Counter sink screws and install plug at open shelving cabinets. STORAGE NO. 3206 0 1. Paint one coat of paint to cover patched walls. 2. Paint wood door trim on inside of Storage Room. ART FFICE NO. 3208 1. Remove paint from Door No. 3210. 2. Clean interior windows. 3. Install back to room sign at window. {/ 4. Re-install ceiling pads. 5. Touch up paint on glazed block wall at window. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508) 520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 12, 2001 Northampton High School KB #96079 Page 3 of 6 AUDITORIUM STAGE NO. 1205 1. Adjust closing speed on Door No. 1205 to have positive latch. 2. Clean kick plates on Door No. 1205. 3. Fire caulk wall around duct at elevator. 4. Paint blank cover "blue to match" or install required electric. ELECTRIC ROOM NO. 1206 I. Fire caulk all openings through wall and ceiling. 2. Install missing screws to both closer brackets. 3. Complete electric wiring. ELECTRIC STORAGE NO. 1207 1. Fire caulk all openings in wall and ceiling. 2. Complete electric. 3. Paint door& door frame. VESTIBULE NO. 1208 1. Paint east wall. 2. Provide escutcheon on sprinkler head. :1Z 3. Paint cast iron pipe. f9 4. Touch up door frame to Door No. 1208A. 5. Paint door frame to Door No. 1208B. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 12, 2001 Northampton High School KB # 96079 Page 2 of 6 CORRIDOR.NO. 2203 �1. Remove blue paint from wall at Door No. 2207. 2. Replace water damaged ceiling pads. 3. Clean or repaint the wall on north side of stairs. UPP J R BALCONY NO. 2202 1. Touch up noticeable scratches in UmStrut bus bar, particularly at door entrances. 2. Clean base at north wall. 31 Paint base at bottom rail. 4 glass to Projection Room. 5. Remove all door construction identity tags from hinges (typical). PASSAGE WAY NO. 1218 ✓ 1. Replace damaged ceiling pads. STAIR NO. 21 1. Remove large grill and clean floor at bottom of grill. 2. Touch up wood base on each side of grill. Clean face of all glazed block to exterior. 4. Clean all risers and stair stringers. 5. Repair top of metal door No. 1216 (bent). 6. Correct construction damage to existing wood casing at top of door. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860) 229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 12, 2001 Addition&Renovations Northampton High School Northampton, MA Prepared By: Robert LaMontagne KB # 96079 UPPER AUDITORIUM LOBBY NO. 2209 1. Install 4x4 face duct grill at south wall. 2. Patch to match crevice in wall above Double Doors No. 2201B. 3. Adjust height of spot light fixture so ceiling pad will rest on grid. STORAGE ROOM NO. 2204 1. Install ceiling in Storage Room unless otherwise directed by Traci. OT 1?'r1/W 2. Remove abandoned boxes (telephone) from wall. —%kk, - 3. Install ASA plate for positive latch. 4. Install protective grill to light fixture. DRAMA ROOM NO. 2206 1. Replace damaged ceiling pad at entrance. 2. Touch up walls and wood base on north wall. :�/ Patch to match holes in south and west walls. 4. Clean or replace all ceiling tiles with obvious fingerprints. ROONYNO. 2202 1. Patch screw holes and paint all wood nailers under counter that are noticeable upon entry into lower landing. 0/�2. Re-install ceiling pads on north wall. �4. Touch up paint on base of entire window. Remove paint from electric cover. STORAGE ROOM NO. 2207 C' 1. Adjust ceiling pads to rest on ceiling grid at smoke detector. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 r -------, -- r - KAESTLE BOOS ASS(�X,'1ATES,1(`C. ARt,HITECTS March 22, 2001 John A. Kaestle Mr. Robert Aquadro emerinrs Aquadro &Cerruti, Inc. Texas Road Charles W. Boos P.O. Box 656 David W.King Northampton,MA 01061 Mark J.Weisman Michael 1.Blessing Re: Addition & Renovations to Am`r Rusty Malik Northampton High School Michael 1.McKeon Northampton MA Richard F.Webb KB#96079 Jeffery R.NicElravy Dear Mr. Aquadro: Christopher M.Roof Pursuant to my visit to observe work on March 12, 2001, enclosed is the Punch List. Ti,i(i N.Millkowski Please advise me when this work is ready for a re-inspection. Scott i.lvlan"iagh Terry A.McDonald Very truly yours, )ohn W.Juros Lawrence P.Trim Scott D.Pellman Janice K.Llntner Robert Lamontagne KAESTLE BOOS ASSOCIATES,INC. Daniel Tavares II RL:gh CONNECTICUT Enclosure 416 Slater Road P.O.Box 2590 c: Joseph Misterka (w/enc.) New Britain,CT 06050-2590 Lawrence Fink(w/enc.) Phone:(860)229-0361 William Letendre (w/enc.) Fax:(860)229-5303 MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 E-Mail:kba @kba-architects.com Web:www.kba-architects.com sMa3 IINTSERVER2ldntnlNonhampionICAIPunch Listslugtmrlro03i20 1puncldistdac KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Northampton High School KB# 96079 Page 10 of 10 Room No.3432: ✓� Install ceiling pads. / Install blank on abandoned electric box. r/ Touch up unpainted area on East wall. Remove brown paint from wall at doorway. Stair No. 41: Install ceiling pads. Corri r No.3403: Clean risers to both sets of stairs to B wing. Replace water damaged ceiling pads over lockers-East side. _ P .Install fire extinguisher and paint cabinet. _Clean all locker faces. Clean door to elevator. _ In bathroom(B-Wing)off corridor, replace or clean ceiling pads. Install escutcheon on sprinkler heads- South end of corridor. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Northampton High School KB# 96079 Page 9 of 10 Room No. 3428• Adjust faucet from dripping. Touch up scratch in door. Room No. 3429: Q Replace broken lens to light fixture. Patch holes in wall under handicap sink. Remove paint from windowsill. Ro4 No. 3430: Clean cabinets. Install end cap to radiator. Install blinds in window. Adjust ceiling grid over computer counter so the ceiling pad will set on the ceiling grid. Room No.3431: Re-install ceiling pad. Rooni No.3430: Install escutcheon on sprinkler head. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Northampton High School KB# 96079 Page 8 of 10 Room No. 3421: Remove paint from access door in first toilet stall at window. Patch holes in wall at toilet partition bracket incorrectly drilled. Touch up multi-colored paint at paper towel dispenser. Room No.3423: / Adjust ceiling exhaust grill so that ceiling pad will rest on ceiling grid. Room No.3422: Touch up scratches above door on West wall. Room No.3420: f Install grill on supply duct. ✓ Install height of sprinkler head so ceiling pad will rest on ceiling grid. V Clean laminate doors to new closets. Clean counter top to unit ventilator shelving. Touch up wall or remove blue paint from wall at window panel. Typical-Secure all access panels(12 x 12) in walls. Rolm No.3422: — J Install ceiling pads. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Northampton High School KB# 96079 Page 7 of 10 Corridor No. 3402: _ Clean all lockers. V/' Install Electrical panel covers more securely. Caulk the top of glazed block at multi-colored paint at Door No. 3407. _ Install missing screw to two gang cover at doorway to Stair No. 43. ' i` Install end caps to radiators at window wall. Install fire extinguisher- paint cover or replace. Install escutcheons on all through floor plumbing pipes. Stair o. 44: Clean base on West wall. Clean lens on light fixture. �+ Install cover to electrical box at back of door. Clean door panic hardware. Adjust height of sprinkler head so that ceiling pad rests on ceiling grid. Room No.3420: Caulk or patch,around electrical covers to conceal holes. Clean sink of all construction cement and debris. Be sure drain is working properly. ` Remove construction debris in pipe chase closet. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Northampton High School KB# 96079 Page 6 of 10 Room No.3414: _ Fire caulk all openings through 1 hour fire rated wall. Install covers on electric panels. Room No.3410:J Adjust height of lens in light fixtures to set down properly. Install escutcheon above sprinkler head. Install grill to exhaust duct. Room No.3419: Install shelving unit at unit ventilator. Clean computer table. :11�/ Adjust ceiling light fixture hanger so as ceiling pad will rest on ceiling grid. Clean top of wood trim at South wall. Roam No.3418: f' ✓ Clean top rail wood trim at South wall. Remove paint off base at North East wall. Stain new wood handles on old cabinets. Remove P aint from base at room entrance corner. Correct or replace ceiling pad at South East light fixture. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215, Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Addition &Renovations Northampton High School Northampton,MA Prepared By: Robert E. Lamontagne KB4 96079 Room No.3413 (Cont.): JInstall(5)grommets on counter tops. a! Replace (factory imperfect) ceiling pad at South West corner. Replace (factory imperfect) ceiling pad near light fixture at South West. Patch to match hole in wall under South wall marker board. Room No.3417 L/ Install blank cover to abandoned electrical box in alcove at South wall. a./ Remove VCT the at west wall -extend under base to cover substrate. ✓ Touch up wall paint or remove brown paint at side of unit ventilator. J/ Remove wall paint drops from base under window. Room No.3416: L/ Re-install removed ceiling pads. Adjust ceiling grid on east side to cover joint in ceiling pad. Replace damaged ceiling pad at vent over door. Room No.3415• Replace damaged ceiling pad at East wall. Clean ceiling light lens. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 i KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Addition&Renovations Northampton High School Northampton,MA Prepared By: Robert E. Lamontagne KB# 96079 Room No.3407 (Cont.): �✓ Install blank covers over abandoned electric boxes. ✓ Install missing screw on new existing blank cover. Change blank cover to"Blank goof cover"to cover damaged paneling. ' Stain new base at computer table. Stain edge of door. Room No. 3412: Clean parabolic lens on light fixture. Caulk edges of new marker board. v/ Touch up wall color or remove blue paint over unit ventilator. Remove red paint from wire mold cover on East wall. V Clean all wire mold covers. 1� Stain new handles on existing cabinets. Room No.3413 ✓ Clean all counters -Note: remove and replace any counters that are scratched due to construction abuse related to physically working/walking on unprotected counters. 'f Vacuum rug. Clean marks and finger prints from light fixtures. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Addition &Renovations Northampton High School Northampton, MA Prepared By: Robert E. Lamontagne KB# 96079 Room No. 3409 (Cont.): ✓ Cut off wood shim(or paint black to match)under the unit ventilator. Clean the wire mold cover. Patch hole in wood jambs at side of marker board(front of classroom). ` / Typical—Remove all tape on door numbers on hinges. Room No. 3405 4/ Remove paint/tile cement from unit ventilators base grills. Remove finger pads from ceiling pad(South West light fixture). f Typical—remove manufacturer's tags from all unit ventilators. +� Re-adjust cover plate to computer plug beneath computer table. Remove white paint from base on North West wall. Room No. 3406: a/ Remove paint from the base on unit ventilators. JClean new laminate doors to closets Room No. 3407: Clean tops of unit ventilators. Re-install ceiling pads CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Addition& Renovations Northampton High School Northampton, MA Prepared By: Robert E. Lamontagne KB# 96079 Room No. 3404: —i/ Touch up wall paint at side of clock. J Adjust old closer(door closes extremely fast). / Clean paint off sills at both blocked up windows at South wall. �9 Remove tile cement from leg of computer table. Room No. 3408: Install missing shelves in existing closet. V/ Repaint South wall. ✓ Install marker/tack board(North wall) Adjust(level)top of unit ventilator shelving counter top. U/ Clean computer table. !J Clean white paint from base in alcove on East wall. Patch to match wall at side of 2 gang entrance switch. Install missing base grill on unit ventilator. Room No.3409: Caulk the top.of the new marker board. Install marker/tack board in front of classroom. Stain new handles installed on old cabinets. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 s KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST March 2, 2001 Addition&Renovations Northampton High School Northampton, MA Prepared By: Robert E. Lamontagne KB# 96079 THIRD LEVEL AREA D Stair No. 43• Replace ceiling pad at sprinkler head. Stair No. 42: C Remove paint from the glazed block(South wall). Clean rust off glazed block(South wall) L/ Install missing ceiling. j Replace damaged ceiling pad on the side of the light fixture. V" Remove blue paint on grout at west wall stair mezzanine. L/ Clean panic device on door. Corridor No.3401: Remove red paint off base at corners of South West and South East walls. j Install new ceiling pad at first sprinkler head to cover escutcheon. jClean finger prints from ceiling grid outside Room No. 3408. V Install missing complete row of lockers outside Room No. 3405. Clean all lockers. Install wall grill over"Custodian Closet"door. Install fire extinguisher,paint existing cabinet. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 - r - a.. -- y KAESTLE BOOS ASSOCIATES,INC. ARCHITECTS March 8, 2001 John A.Kaestle emeritus Charles W.Boos Mr. Robert Aquadro David W.King Aquadro & Cerruti,Inc. Mark I.Weisman Texas Road Michael 1.Blessing P.O. Box 656 Am'r zu,iv Malik Northampton,MA 01061 Michael J-McKeon Richard F.weiab Re: Addition & Renovations to Northampton High School Jeffery R.McElravy Northampton MA Christopher M.Roof KB#96079 Dear Mr. Aquadro: Traci H. tililiko�ski Scott I.Mtangiagli Pursuant to my visit to observe work on March 2, 2001,enclosed is the Punch List. Terry A.McDonald John W.luros Please advise me when this work is ready for a re-inspection. Lawrence P.Trim sr_ott D.Pellman Very truly yours, lanice K.Limner Daniel Tavares II Robert Lamontagne CONNECTICUT KAESTLE BOOS ASSOCIATES,INC. 416 Slater Road RL:kmr P.O.Box 2590 New Britain,CT 06050-2590 Enclosure Phone:(860)229-0361 Fax:(8b0)229-5303 c: Joseph Misterka(w/enc.) Lawrence Fink(w/enc.) MASSACHUSETTS William Letendre (w/enc.) 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 -Mail:kba @kba-architects.com Web:www.kba-architects.com IWTSCRVF.R11DuluWarthumprnnlCAV'trnchLislvkrepiadrn030?0!/nrnchlist.doc KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB#96079 Page 10 of 10 Roo N o. 2430 =Clean cabinets Adjust height of cabinet doors to align Corridor No. 2404: Install magnetic hold opens Storage Closet: t/ Complete electric Stair No.41: J, Install ceiling pads Clean stainless steel 2 x 2 angle at ceiling Clean glazed block CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB# 96079 Page 9 of 10 Rooin No. 2426: Adjust ceiling light so ceiling pads will rest on grid lClean excessive finger prints off ceiling light fixture Install flag staff bracket Q Re-cut carpet under computer cabinet East wall Room No. 2423: Install escutcheon on sprinkler head : . Adjust doors to remain closed when not in use Correct lock to handicap door(does not lock) Room No. 2427: _7 Install escutcheon on sprinkler in cabinet alcove Remove paint from wire mold-West wall Remove plastic from parabolic light fixtures '//eplace ceiling pad near sprinkler head Replace second ceiling pad in same area(damaged from factory) Clean windows Room No. 2431: CyReplace two (2) dead light bulbs in ceiling fixture Install door bumper CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508) 520-0856 I KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB# 96079 Page 8 of 10 Corridor No. 2401: Reinstall ceiling pads Install magnetic hold opens at door Clean light fixture lens (15`fixture South side) 1/ Replace broken light fixture lens (2°d fixture) Paint fire extinguisher cabinet -east wall Stair No. 42: Install missing hardware on double doors + Clean stairs and railings Corridor No. 2402: Install ceiling pad Replace damaged ceiling ad near speaker at Door No. 43 P g gp Patch hole in electric panel cover(South West corner of corridor) Patch hole in glazed tile at Door No. 2416 Clean water fountain(West side) _V Remove magic marker from glazed block near windows Paint fire extinguisher cabinet /i Install fire extinguisher Reinstall ceiling pads Clean water fountain(East side) CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB#96079 Page 7 of 10 Room No. 2413: Patch(caulk) large crack in wall _l Paint or stain door jamb at ASA plate 1/ Install blank cover on duplex electrical box behind door Roorn No. 2412: Touch up scratches on front of unit ventilator Stain or paint new base at unit ventilator Install flag staff bracket Install missing lense on light fixture Room No. 2424: 11 Clean brick dust off wall in handicap toilet stall Correct lock(does not lock) on door to handicap stall Adjust doors to stay closed when not in use on toilet partition Install escutcheon on sprinkler head in ceiling Roo o. 2422: Adjust closing speed on door closer CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB#96079 Page 6 of 10 Room No. 2410 Cont. Install new mull center over science casework door in island casework L/ Replace ceiling pad in North West corner of ceiling Putty holes and paint casing on closet doors Room No. 2411: _V1 Remove plastic from lights Install missing ceiling pads ( Install metal shelves in unit ventilators L/ Clean brown paint off south wall wire mold New marker board short 1" in some places -install trim Room No. 2405: _ Install ceiling pads _ Install electrical control box under sink Tape gaps in pipe insulation Install missing screws from door hinges t/ Adjust door closer(too hard to open) Clean toilet partition Correct lock on door to handicap stall- (does not lock) CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB#96079 Page 5 of 10 Room No.2408: IV Adjust light fixture bracket so ceiling pads will sit on ceiling grid 4 Install three missing shelves in wood cabinets Stain planed edge of door were finish was removed Replace ceiling pad over sprinkler head at 2406 B Door Room No. 2407: Adjust light fixtures so ceiling pads will rest on ceiling grid Clean windows Stain planed edge of door where finish was removed#2407 C Remove all tags from door hinges (Typical) Room No. 2406: I./ Remove part of old dead bolt on door jamb and patch IJ Install marker boards Reinstall removed ceiling pads Room No. 2410 Adjust ceiling light brackets so ceiling pads will sit on ceiling grid Install marker boards Correct faucet from dripping in sink Install new mull center stop at door in West wall casework CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508) 520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB#96079 Page 4 of 10 Room No. 2418 A& B: Install base Patch large hole in ceiling V/ Patch hole in corridor wall Install missing floor tile ' YPatch hole in ceiling at conduit Install cover to duplex plug Room No. 2409• Install flag staff holder Install metal shelf on unit ventilator _ Remove extra wood shelf in cabinet on North wall and install in Room 2408 Remove nails from casing at top of cabinet y stall blank plate at abandoned electrical box on West wall stall blank plate at abandoned electrical box on North wall Patch East wall above base in small alcove Clean excess plaster drilling powder from base on South wall CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB#96079 Page 3 of 10 Room No. 2416• .Remove plastic from parabolic light fixtures 1/ `Clean windows _—Y"Remove wall paint from wood door casing Install screws in door hardware backset ' VReplace damaged new wood door(large chip in laminate, top of door) Lower light fixtures to allow ceiling pads to rest on grid :r)l Install flag staff bracket Touch up wall paint at door bumper Stair No. 43: ;> Install magnetic hold opens Paint over brown fire caulking on South wall Remove excess paint off black base R om No. 2409: f Install missing light fixture Remove plastic from light fixtures Clean cement off top rail of marker board Adjust light fixtures so ceiling pad will rest on ceiling grid CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Northampton High School KB#96079 Page 2 of 10 Room No. 2420: Clean Windows _ Remove plastic from lights 1,/ Adjust light chain holder brackets to allow ceiling pads to sit on ceiling grid Install flag staff holder ' Patch hole in wall above base under computer table. Room No. 2419: Install marker boards on South wall Remove plastic from light fixtures Clean windows Install flag staff holder Room No. 2417: Remove paint from oak paneling under counter on North wall Install marker board over existing chalkboard Install cover plates on duplex plugs t,//, Remove blue paint or touch up wall at center window sill I Clean all counters `Remove excessive fingerprints from light fixtures Patch hole in leg of East section of counter CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860) 229-5303 P: (508)520-9928 F: (508)520-0856 a � KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST February 23, 2001 Addition&Renovations Northampton High School Northampton, MA Prepared By: Robert E. Lamontagne KB#96079 SECOND LEVEL AREA D Room,No. 2421: —//Replace broken glass in exterior window "kemove or touch up excess paint on wall over door casing ' i )nstall staff bracket V,/� " =Patch and paint hole in West wall above wire mold Clean tops of all exterior wall counters and H.C. computer table Remove paint and clean window frame at sill Re-paint corridor side of door p V Caulk top of wire mold on West wall Paint West edge of chalk board rail ✓ Remove brown paint from East side of wire mold JRemove excess brown paint from chalk board at rail ✓' Patch hole in wall where projection screen was installed Remove plastic from ceiling lights JClean windows CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Stater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508) 520-0856 KAES T 1_E BOOS ASSOGIATES,ING. ARGHl TEGTS March 5, 2001 John A.Kaestle emeritus Charles W.Boos Mr.Robert Aquadro David W.King Aquadro & Cerruti, Inc. Mark I.Weisman Texas Road Michael J. Blessing P.O. Box 656 Am'r Rusty Mark Northampton, MA 01061 Michael J.McKeon Richard F.wehh Re: Addition & Renovations to Northampton High School ierfery R.McElravy Northampton MA Christopher Ni,Roof KB#96079 Mili ri, Dear Mr. Aquadro: Tr,.ci l+.owski S(cat 1.Mangiagh Pursuant to my visit to observe work on February 23, 2001, enclosed is the Punch List. Terry A.M(.Donald Jahn W.Jr los Please advise me when this work is ready for a re-inspection. Lawrence P.Trim Scott D. Pellman Very truly yours, Janice K. Linmer Daniel Tavares II Robert Lamontagne CONNECTICUT KAESTLE BOOS ASSOCIATES,INC. 416 Slater Road RL:kmr P.O. Box 2590 New Britain,CT 06050-2590 Enclosure Phone:(860)229-036'1 Fax:(860)229-5303 c: Joseph Misterka(w/enc.) Lawrence Fink(w/enc.) MASSACHUSETTS William Letendre (w/enc.) 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 -Mail:kba@kba-architects.com ',Web:www.kba-architects.com i " 1Sv try K:WnrthnmpfnnlCAlPnnchLislslnc�adm01280lpm,chlrsLcloc KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST January 23,2001 Northampton High School KB # 96079 Page 2 of 2 B. Trucks&Rigging(Continued): 8. End stops have to be provided on all tracks. 9. Specification dictates the Scenic Track to have 176 carriers Walker provided approx 110 carriers 10. Toe ropes and clamps have to be attached to the 96 roter drape 11. All existing head blocks have "to be removed". There are presently 13 pieces of head block equipment still attached to existing walls and carriers. 12. Curtains have to be labeled "Fire Retardant". This could not be verified. 13. Provide the owner with on site training. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST January 23, 2001 Addition& Renovations Northampton High School Northampton, MA Prepared By: Robert LaMontagne KB # 96079 Stage Rigging/Curtains A. Curtains: 1. KBA Specification 2.4-A -Provide not less than 60 percent additional fullness for curtains(7 1/4" lap). — ■ The curtains provided are only 50 percent fullness-(6" lap) 2. Curtains should not be stored on site. They are being kept in a bag(should be boxed)that is already worn from being dragged around the stage by other trades. 3. Provide Border Curtains with lead tae at bottom. B. Tracks&Rigging: 1. All 1/4" shackles at pipe battens have to be secured with bailing wire .2. All cables to have bailing wire at main cranks&turnbuckles 3. All cable ends have to be terminated and taped off 4. All walk along tracks(scenery tracks)cannot exceed 4 feet between supports. (KBA 3.4-A-2) Walker provided supports at approx 6-0" _ 5. The main traveler(Heavy duty track)cannot exceed 6'-0"between supports (KBA 3.4-A- 1 -Walker provided supports at approx 8'-0" 6. Cable crank assembly has to be secured with a "#5 rated bolt" The crank is now secured with lag bolts VJ 7. Base mounts for the cable cranks have to be secured to"concrete"with rated bolts. They are presently secured to the wood floor with lag bolts. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 t KAESTLE BOOS ASSOCIATES,ING. ARCHITECTS January 29, 2 1 John A.Kaesde Mr. Robert Aquadro emeritus Aquadro & Cerruti, Inc. Texas Road Charles W,Boos P.O. Box 656 David W.King Northampton,MA 01061 Mark J.Weisman Michael J. Blessing Re: Addition & Renovations to Ar»'r Rusty Malik Northampton High School Michael J.McKeon Northampton MA KB#96079 Richard F.Werth Dear Mr. Aquadro: Jeffery R.McElravy Christopher M.Roof Pursuant to my visit to observe work on January 23, 2001, enclosed is the Punch List. Traci H.MiIikow,;ki Please advise me when this work is ready for a re-inspection. Scott J.Mangiagli Terry A.McDonald Very truly yours, John W.Juros Lawrence P.Trim Scott D.Pellma" Robert LaMontagne Janice K.Linmer KAESTLE BOOS ASSOCIATES,INC. Daniel Tavares II RL:kmr CONNECTICUT Enclosure 416 Slater Road P.O. Box 2590 c: Joseph Misterka(w/enc.) New Britain,CT 06050-2590 Lawrence Fink(w/enc.) Phone:(860)229-0361 William Letendre (w/enc.) Fax:(860)229-5303 MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 :-Mail:kba@kba-architects.com Web:www.kba-architects.com M" M-0=1 \\NTSERVER2\Data\Northampton\CAT unchLists\aquadro01230ipunchlist.doe 4�a.�lYS.Y4"S3i'3L.�Lt�K.�`�v�' 1Jff9 .r December 21, 2000 Mr. Robert Aquadro Aquadro&Cerruti, Inc. Texas Road P.O.Box 656 Northampton,MA 01061 Re: Addition &Renovations to _ Northampton High School Northampton MA KB#96079 Dear Mr. Aquadro: I am writing in response to the letter from Dant-Clayton Corporation dated December 15, 2000, regarding the installation of the galvanized handrail systems at the Grandstand. The information stated in the letter is correct. In a telephone conversation with Mr. Lewis, I verbally approved the substitution of galvanized pipe in lieu of extruded aluminum pipe in order to obtain the code required maximum outside diameter of 11/z". The second item on the Punch List dated October 31, 2000, can be deleted. The installation of the galvanized rails is acceptable. Considering that the aluminum rails are specified to have an anodized finish, the galvanized rails are to be finish painted to achieve an equivalent substitution. Very truly yours, Traci H. Milikowski,RA Associate KAESTLE BOOS ASSOCIATES,INC. THM:gh Enclosure c: Joseph Misterka(w/enc.) Lawrence Fink(w/enc.) William Letendre(w/enc.) K:\NorthaniptonWrchStructInt\Correspondence\AquadroWquadro 122 1 00grandstand.doc l KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST October 31,2000 Northampton High School KB #96079 Page 2 of 2 lean the aluminum exterior of the base of the Bilco door unit. File excess aluminum weld on corners of Bilco door unit aluminum base. rind excessive amount of splattered weld on aluminum base. lean paint off interior vinyl wall at West Doorway near hinges. lean wood staff moulding at exterior door jambs at the hinge side. orrect bottom of vinyl corner at the back of the west side of the scorers encloser;bent and protruding. Clean all vertical posts on the guardrail on the roof of the scorekeeper's enclosure. Repair dent in aluminum floor planking at the bottom of the 6t°row bleacher seats on the West side. Remove Painted name Northampton on vertical post at both ramps. can all vertical post at the east and west ramps. f Install bolts to fill incorrect drilled holes in aluminum boxers at base of ramps. Install guard rail on concrete base at the middle landing of both east and west ramps. Clean all aluminum boxers at the base of ramps. Provide wide sloped low step incline at the bottom riser of the lower steps to correct code violation 8 '/4" rise. Maximum 7"rise. pn _ Grandstand bleacher handrails do not comply with KBA Specification Section 2.02.2. (Handrail shall extend 12"past the nosing of the last riser at the top.) (/ Provide all handrail post with cast aluminum top caps. Correct the 3/16"gap in the main longitudinal portion of the decking. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST October 31, 2000 Addition&Renovations Northampton High School Northampton, MA Prepared By: Robert LaMontagne KB #96079 Grandstand Correct alignment of base to stair guard rails. Four sided base must align with stair deck members. Replace all galvanized handrails with KBA specified anodized, extruded aluminuminum pipe. Railings at ramp not complete: See above note. !*A� Aeplace handrails at bottom of stairs at center section.They are bent and distorted. See above note. Infill large opening in the decking at the top of both ramps on the corner at the base of the stairs. Replace the damaged aluminum cap on the railing support at the top of the lower section of stairs. Replace the dented aluminum threshold joint cap on the main deck near the center set of bleacher stairs. Check ends of all seat brackets for rough edges. Edges must be filed or ground down. See example at the fourth row on the east side of the bleachers. Remove blue paint(?)off the standing deck at the top of the bleacher seats on the east and west side. emove curled drill burrs at bolted holes under seats. 11 walkways and footboards require end caps on all sides. Install all missing end caps. Level crooked post on railing post at the bottom of the center bleacher stairs. Clean all aluminum handrail and guardrail vertical posts. eplace damaged vinyl corner on siding at west side at the bottom of the scorekeeper's enclosure. Paint a second coat of paint on both doors and door jambs. lean brown paint off the ceiling near the trim of the Bilco door opening. Clean white paint(?)off ceiling near the rear of the ladder at the wall. eplace bad cut on left top side of door casing on east door. Clean all glass;remove labels. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860) 229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 111Z Id KAESTLE BOOS ASSCGIATES,INC. A R C H-1 T E.-C.I.S, November 7, 2000 John A. Kaestle Mr. Robert Aquadro emeritus Aquadro& Cerruti, Inc. Charles W.Boos Texas Road P.O. Box 656 David W.King Northampton,MA 01061 Mark J.Weisman Michael J. Blessing Re: Addition &Renovations to Arn'r Rusty Malik Northampton High School Michael J.McKeon Northampton MA KB#96079 Jeffery R.McElravy Christopher M.Roof Dear Mr.Aquadro: Richard F.Webb Enclosed is a Punch List I prepared from an on-site visit on October 31, 2000. Jamie L.DiPinto Please advise me when you are ready for a re-inspection. Vincent R.Amrhein Traci H.Millkowski Very truly yours, Scott J.Mangiagh Terry A.McDonald John W.Juros Lawrence P.Trin) Robert E. Lamontagne Scott D.Pellman KAESTLE BOOS ASSOCIATES,INC. REL:1ch CONNECTICUT Enclosure 416 Slater Road P.O. Box 2590 c: Lawrence Fink(w/enc.) New Britain,CT 06050-2590 Joseph Misterka(w/enc.) Phone:(860)229-0361 William Letendre (w/enc.) Fax:(860)229-5303 MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 E-Mail:kba @kba-architects.com Web:www.kba-architects.com °� : KAESTLE BOOS ASSOCIATES, INC. WINDOW PUNCH LIST October 10, 2000 Northampton High School KB# 96079 Page 2 of 2 L/ Room No. 2506—Clean caulk off sills J Room No. 2506—Clean paint and caulk off window frames C/ Room No. 2507—Clean Greenhouse windows i� Room No. 2507—Complete caulking at window base V 'oom No. 2512—Clean paint off interior frames Room No. 2512—Clean interior window frames Room No. 2514—Clean outside glass Room No. 2514—Clean paint off window Room No. 2514—Clean interior window frame e� Room No. 2515 —Clean interior frame �✓ Room No. 2515—Clean paint off frame e/ Room No. 2515 —Clean outside glass Room No. 2515 —Clean caulk off top and bottom of interior panel Room No. 2516—Clean outside glass Room No. 2516—Clean interior window frame Room No. 2518—Clean paint off interior window frame CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 t KAESTLE BOOS ASSOCIATES, INC. WINDOW PUNCH LIST October 10, 2000 Addition &Renovations Northampton High School Northampton, MA Prepared By: Robert Lamontagne KB# 96079 Lower Level Area E Room No. 0503 —Clean caulk off interior glass, clean cement off sills, clean outside of glass Room No. 0504—Clean outside of glass Room No. 0505 —Caulk bottom of window at base Main Level Area E V Room No. 1505—Clean exterior of glass V Room No. 1506—Clean exterior of glass tJ Room No. 1507—Clean outside glass Room No. 1507—Caulk 8"mull center at bottom Room No. 1508—Clean exterior of glass Room No. 1508—Caulk window trim at mull center Room No. 1509—Clean exterior of glass Room No. 1517—Clean outside glass Upper Level Area E Room No. 2503 —Clean exterior of glass r' Room No. 2504—Clean exterior of glass ✓; Room No. 2505 —Clean interior panels Room No. 2505 —Clean interior window frame CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 r- °------ KAESTLE BOOS ASSOCIATES,INC, ARCHITECTS October 17, 2000 John A.Kaestle Mr.Richard Aquadro emeritus Aquadro & Cerruti, Inc. Texas Road Charles W.Boos P.O. Box 656 David W.King Northampton,MA 01061 Mark J.Weisman Michael J.Blessing Re: Addition&Renovations to - Am'r Rusty Malik Northampton High School Michael J.McKeon Northampton MA KB#96079 Jeffery R.McElravy Roof Dear Mr. Aquadro: Christopher M.Roo Richard F.Webb pursuant to my visit to observe work on October 10, 2000, enclosed is a Punch List. Jamie L.Di Pinto Please advise me when this work is ready for a re-inspection. Vincent R.Amrhein Traci H.Milikowski Very truly yours, Scott J.Mangiagh Terry A.McDonald John W.Juros Lawrence P.Trim Robert Lamontagne KAESTLE BOOS ASSOCIATES,INC. Scott D.Pellman RL:lh CONNECTICUT Enclosure 416 Slater Road P.O. Box 2590 New Britain,CT 06050-2590 Phone:(860)229-0361 Fax:(860)229-5303 MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 E-Mail:kba @kba-architects.com Web:www.kba-architects.com KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB# 96079 Page 7 of 7 2509 Darkroom Incomplete. 2509 C stodian 7Paint wall at slop sink. ]/Adjust trim at light fixture. _ (Y Adjust ceiling tile at diffuser. 2510 lectrical 7Finish paint all. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB# 96079 Page 6 of7 Patch south wall at electrical device. Install adjustable shelves in peninsulas. 2504 Chemistry Prep Finish installation of fume hood end panel. �/ Install wood trim at fume hood. V Replace scratched face panel of fume hood. Replace damaged ceiling tiles. Install make-up air diffusers at fume hood. Patch hole,west wall high. Clean all rubber base. 2517 C emistry Storage Install door hardware: levers, closer, silencers. 2503 Chemistry l� I stall wood trim at fume hood. In tall make-up air diffusers at fume hood. Install access panels at six(6) sink locations in peninsula casework. Adjust ceiling tiles at smoke/heat detectors. Adjust devices in wiremold, west. 2520 O Tice Repalce ceiling the at sprinkler head. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5,2000 Northampton High School KB# 96079 Page 5 of 7 Install keyboard tray at handicapped computer station,west. Install missing ceiling tile at window. 2515 Prep Wire glass in door(review Drawings for 1 hour rating requirement) ; Finish wood trim at fume hood, right side. install make-up air diffusers at fume hood. Patch wall at vent piping to Flammable Storage cabinet. Paint exposed piping at Flammable Storage cabinet. Patch east wall at cut electrical device cover, near casework. 2516 Physics nAdjust base cabinet doors near door to prep. /Instal missing ceiling tiles. L/ Clean rubber base. Replace ceiling the at sprinkler head, southwest. j� P int wall above Hamden panel, north. Adjust troffers in pendant lights. 2505 Chemistry Adjust ceiling tiles at smoke/heat detectors. � Install access panels at six(6) sink locations in peninsula casework. Paint south wall at fume hood. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB#96079 Page 4 of 7 2518 Biology Prep Relocate small diffuser located in center of grid. s Caulk at epoxy countertop/backsplash, north. Reinstall v.c.t. flooring at northwest corner(wide joints). , Patch west wall at backsplash. 2512 iology Install rubber base,north door. / Paint east wall at telephone outlet. �,✓ Adjust escutcheon at pendant light fixture, center. Adjust doors at sink base cabinet, south. Adjust latches on base cabinet, south far left. 2519 ffice Adjust devices in wiremold, north. Gap in rubber base at door frame. 2513 Small Classroom Install sprinkler heads. �L Patch wall at wiremold, east. Paint north wall, east side. 2514 eneral Science 7Wash/wax floor. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB# 96079 Page 3 of 7 ✓ Paint exhaust fan ductwork and metal trim, east and west. Paint wall at soil cart locations(2). L/ Greenhouse window repair? L/ Replace ceiling tile at sprinkler head, east end. L/ Replace damaged ceiling, center. 0 Caulk at epoxy countertop/backsplash, north. ' Adjust base cabinet door far right, south wall. Install adjustable shelf, west. 2506 Prep Room filled with Owner's boxes. Casework and counters not visible. 1� Install rubber base, south wall. Paint wall at switch,south wall. Install rubber base behind refrigerator. 25111 Biology Clean rubber base, east and west. Install rubber base, north. l/ Clean glass upper cabinet, south far right. Wire glass required at Prep Room door 2518A (confirm rating). ? Reinstall(4)diffusers located off center of ceiling grid. V Paint wall at door head 2511. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB#96079 Page 2 of 7 Resurface existing tackboard, east. 2502 Corridor Resurface all tackboards. Install electrical device cover above tackboard, north wall east end. _ JReplace purple joint covers at locker trim. V Remove tape from ceiling grid near room 2519. Adjust locker door 2205. Install electrical device cover at Door 2514. 2506 Biology Install rubber base, east. Install rubber base at Door 2506A. Install electrical device at Door 2506A. (or patch wall, cannot remember!) Adjust ceiling tiles at window pocket. L, Adjust catch on base cabinet, center south wall. Adjust base cabinet doors, south wall far left. �! -lean base cabinet drawers inside, all. Paint north wall. Loud rattle in diffuser near emergency shower. 2507 Greenhouse Adjust signage flush with wall. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Addition & Renovations Northampton High School Northampton, MA Prepared By: Traci H. Milikowski KB# 96079 Second Level Area E General Note: Most epoxy resin tops were covered with Owner's boxes and not able to observed. Surfaces appear to be scratched. Clean tops and sinks. Adjust or caulk at gaps in backsplash to countertops (several locations). Windows are not included in this Punch List. Paint all electrical panel sheet metal covers in corridors. Complete fire extinguisher cabinet repair in corridors, install fire extinguishers. (� Install fire extinguishers in cabinets in all labs. Install goggles in eyeglass monitors in all labs. Paint exposed piping at all emergency eyewash/bodywash stations. Remove tape from walls and doors designating room numbers. Install all sliding markerboards. Install all tackboards. istall grommets in epoxy countertops at all computer workstations. s Adjust all door closers. Doors not latching. 2501 Cridor Nice touch,but replace purple joint covers at locker trim. Install tackboard(or paint)at exposed concrete block, east wall. Patch wall at electrical device, south wall. Paint base or install green rubber base at locker end wall near Room 2506. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB# 96079 Page 7 of Install escutcheons at sprinkler heads. 0311 Team Room Z"kepair ceramic tile base at column. r J Install number plates on lockers. Paint wall mounted bench brackets. 03,12 ,A�llccove L' Install escutcheon at sprinkler head. �1 /Fill hole at pipe penetration in west soffit. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5,2000 Northampton High School KB# 96079 Page 6 of 7 r' 0307 ocker Repair vct at marble threshold. Install escutcheons at sprinkler heads. Replace damaged ceiling tile. 03 HCT Install lav guard at sink. Clean tile walls at shower. Install escutcheon at sprinkler head. Install locker number plates. 0309 Showers Caulk at plaster ceiling/ceramic wall tile. Install piping enclosure from partition to ceiling,typical of all. lean stained grout in floor tile. Clean marker from ceramic tile floor. nstall curtain at h.c. stall. Clean grout at ceramic tile walls,re-grout as required. 0310 Toilet aint at door frame 031113. Adjust shoe at pilaster of h.c. stall. Remove plastic from base of express lay. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5,2000 Northampton High School KB# 96079 Page 5#f 7 Replace damaged ceiling tile near light fixture. t/ Install escutcheon at sprinkler head near door 0304. 0325 forage Clean floor. - 0326 Fitness No lights were on at time of Punch List. Install electrical panel cover plate and paint, east. f Install tackboard,north. l Install escutcheons at sprinkler heads in alcove area. 0322 Storage Complete. 7 0304 iris' Locker Install tackboards,north and west. Install escutcheon at sprinkler head in vestibule area. 0305 Passage Install escutcheons at sprinkler heads. Adjust closer on Door 0305. 7 0306 Mee stall tackboard. Install escutcheon at sprinkler head. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB# 96079 Page 4 of 7 Replace locker M088 with filler panel. (Review shops) Replace broken floor tile in aisle, east end. Replace green filler panel in northeast row. Scuffed door frame 0323A. 0302 Corridor Repair rubber base at pilaster, north end east wall. Adjust ceiling tile at speaker. 0322 Custodian Complete. 0320 'ainer Install sink complete with lav guard. Install icemaker. Install electrical device, north. Install undercounter refrigerator, east. 0321,Storage Install electrical device cover on west side of column. 0303 orridor Clean dirt east,wall and all window stools. Magnetic hold on Door 0302C not operational. Adjust ceiling tile at speaker. Replace ceiling tile at sprinkler. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB#96079 Page 3 of 7 Install closer on door. (check hardware set) V/ Patch wall at water closet. G nstall missin g g ceilin tiles. V Clean ceramic the walls at shower. 0318 hovers j Caulk at plaster ceiling/ceramic wall tile. Install piping enclosure from partition to ceiling,typical of all. 1 Clean stained grout in floor tile. 7 , Clean marker from ceramic tile floor. XInstall curtain at h.c. stall. Clean grout at ceramic the walls, re-grout as required. 0324�Locker Alcove Paint bench brackets. 0319 Toilet Clean pencil marks from wall and floor at partitions. Clean walls and floor. Replace cove tile at Door 0323B. 0323 Team Room Paint bench brackets. Replace locker M005 with filler panel. (Review shops) '' CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,.Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5,2000 Northampton High School KB# 96079 Page 2 of 7 /Install ceramic tile base at access panel below drinking fountain, south. 1 Paint low wall at entrance to showers. Replace yet another great filler panel color at locker bank, north wall center bank. /Install sloped tops at center locker bank. Install tackboard, west. Replace chipped floor tile,northwest, second locker bay. 0314 Passage Clean west wall at door to Area A. 2— Install ceiling tiles. 7 0315 ffice Patch east wall at electrical device. Replace damaged ceiling tile. ;'Patch west wall at electrical device. t Electrical devices at south wall covered by desks. Review, patch as required. 031 Locker Patch wall at signage. Adjust hardware at locker 3. Install sloped tops at lockers. 0317 Toilet Install sink, complete with lav guard. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Addition&Renovations Northampton High School Northampton, MA Prepared By: Traci H. Milikowski KB# 96079 Lower Level Area C Gener L Address installation of control joints in ceramic the floors. " f Remove tape from floor drains. / Touch up paint at h.m. door frames/multi-colored paint walls. 0301 Corridor Replace all damaged ceiling tiles along south wall. Adjust ceiling tile in vestibule area to Area B,north. 7 Patch/paint h.m. frame to Storage 0204. 7/ Adjust recessed light fixture in door pocket to Boys Locker 0313. Replace damaged ceiling tile, center. 0202 Corridor Vnstall missing ceiling tiles. 0201 orridor Clean rubber flooring at Aerobics vestibule. 0313 Boys' Locker L// Clean stained grout in first bay of lockers near entrance vestibule. Install tackboard, south. Replace damaged ceiling tile in vestibule area. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Addition &Renovations Northampton High School Northampton,MA Prepared By: Traci H. Milikowski KB# 96079 Partial Main Level Area C 1310 irls' Dressing 7Clean/paint scuff marks, south wall. y Clean door. Clean casework. 13, /11 Boys' Dressing ( Ceiling mounted light fixture not operational. Install door stop. a� Clean/paint scuff marks, south wall. Clean rubber base. 1301 Corridor A,nstall missing ceiling tiles. ///Three light fixtures not operational. -Clean rubber base. l sAd'J ust lens in light fixture, east end. Adjust ceiling tiles in grid, east end. Install rubber base at wood bench ends. i Reinstall rubber base at corner condition of wood bench. Replace cut tiles at round cuts in tile pattern at entrance to Media Center. Clean grout at edges of glass block. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB#96079 Page 4 of 4 aint base at locker end near door 051913. Clean rubber base. 0501 Corridor ;'/Replace cut tile at blue clover pattern, north end. Stair E1 Exposed wiring at Lower Level east. Paint all treads. —�z Install recessed entry mat. iy,, Finish paint handrails and brackets. Install electrical device in ceiling of lower to main level landing. f LInstall sprinklers. r' Remove cover from electrical device at Second Level. Patch wall at Area of Rescue panel at Second Level. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 l KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB#96079 Page 3 of 4 i 1502 Corridor ,/,/Remove high voltage sign at Electrical 1525. I /Patch wall at cover plate above lockers, near entrance to room 1513. Install missing ceiling tiles. l Adjust locker door M092. ` ,,/Remove pencil marks on ceiling grid near room 1514. Replace two damaged ceiling tiles above Door 1515A. Install tackboard near room 1517. Adjust fire extinguisher cabinet door near room 1516. /Clean double egress doors at west end. Install threshold at double egress doors. i 1503'Corridor Install electrical device, east wall. Lower Level Area E 0502 Corridor JZ omplete fire extinguisher cabinet repair near Boiler Room door. f Adjust locker door G068. Y Clean glazed block walls,north. ?Adjust 1 locker G094. djust ceiling tile near Door 0511B. locker door G045. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5, 2000 Northampton High School KB#96079 Page 2 of 4 1405 Ylestibule Paint hollow metal frames(bases) at main entrance set of frames. Install recessed entry mat. Clean existing black base. 1415 Passage ` eplace ceiling tile at recessed can light fixture. Replace ceiling tile at east end. 1401,Corridor Install grille at radiation, east wall north end. / Replace sprinkler head with recessed type at soffit to Boys' Toilet, Clean east wall across from Stage. Install rubber base at double egress doors between D and E. Main Level Area E 150 1 Corridor [, Install missing ceiling tile. Replace ceiling tile at sprinkler across from room 1508. nstall tackboard, east. Scratched locker M143. Adjust lens on light fixture near room 1512. Paint doors 51 C. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST September 5,2000 Addition&Renovations Northampton High School Northampton, MA Prepared By: Traci H. Milikowski KB#96079 Lower and Main Level Areas D and E Corridors General ^ Paint all electrical panel sheet metal covers. Paint P-1 at all repairs of 1940/1966 stair demolition, Areas D/E. Refer to ASI. JComplete fire extinguisher cabinet repair, install fire extinguishers. Main Level Area D 1404 Corridor /Install sprinkler head. 14,033 Corridor Patch hole in black base, east wall south end. C/ Paint wall at bullnose wainscot near Toilet 1433, east wall. Install lockers,west wall north end. Finish paint north wall at Stair D4. 14:7�nstall rridor missing ceiling tiles. /,Replace ceiling tile at speaker,west end. Replace yellow cut tiles in round pattern at main entrance. Replace yellow cut tiles in clover pattern. Paint doors 140513. Paint hollow metal frames (bases) at main entrance set of frames. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215, Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIA_TES,IN_C. ARCHITECTS September 6,2000 John A.Kaestle Mr.Robert Aquadro emeritus Aquadro & Cerruti, Inc. Texas Road Charles W.Boos P.O. Box 656 David W.King Northampton,MA 01061 i Mark J.Weisman Michael J.Blessing Re: Addition &Renovations to Am'r Rusty Malik Northampton High School Northampton CIA Michael J.McKeon KB#96079 Jeffery R.McElravy Dear Mr. Aquadro: Christopher M.Roof Richard F.Webb Enclosed are the following Punch Lists generated by my walk-thru on September 5, 2000. Jamie L.DiPinto Vincent R.Amrhein • Lower Level Area C Traci H.Milikowski 0 Partial Main Level Area C Scott J.Mangiagli ' Lower&Main Level Areas D and E ■ Second Level Area E Terry A.McDonald John W.Juros please incorporate these with previously issued Punch Lists, and advise me when you are Lawrence P.Trim ready for a re-inspection. Scott D.Pellman Very truly yours, CONNECTICUT 416 Slater Road P.O.Box 2590 New Britain,CT 06050-2590 Traci H.Milikowski,RA Phone:(860)229-0361 Associate Fax:(860)229-5303 KAESTLE BOOS ASSOCIATES,INC. THM:lk MASSACHUSETTS 124 Grove Street Enclosure Suite 215 Franklin,MA 02038 c: Lawrence Fink(w/enc.) Phone:(508)520-9928 Joseph Misterka(w/enc.) Fax:(508)520-0856 William Letendre(w/enc.) Richard Aquadro(w/enc.) E-Mail:kba®kba-architects.com Web:www.kba-architects.com KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB #96079 Page 4 of 4 WES LEVATION(C-BUILDING) (at Fitness Room) nstall chain link fence below Fitness Room stall cover on electrical box at painter panels e-install or remove wire hanging at aluminum fascia Paint lintel over new window at south west side of building EAST E EVATION(C-BUILDING)(at Fitness Room) Remove bracket at Fitness Room below alum panels on masonry wall. Paint corner of alum panels at inside corner of south wall EA72emove EVATION(C-BUILDING)(at Girls'Locker Rooms) old light fixture at exterior of Girls'Locker Rooms w/ Remove old exterior faucets Remove paint on wall Install blank on exist electrical box CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508) 520-0856 r KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB #96079 Page 3 of 4 atch hole in brick above exterior water valve r Remove excess piece of alum off wall Remove caulk and recaulk around scupper SOUTH LEVATION(C-BUILDING) I/Raint Door and frame 2 coats at Generator Room 0523 X, tall weather striping on bottom of Door Patch hole(new)at elec.box EAST E f+VATION(C-BUILDING) Caulk around 5'X 5' louver at generator Room SO UT ELEVATION(C-BUILDING) 7Patch holes over Door(new)from re-located light fixture Caulk under existing exterior windows at stairwell WEST {EVATION(C)-BUILDING) R ove old light fixture and patch wall Caulk under windows SOUTH ELEVATION(C-BUILDING) ::/lean caulk on brick Remove old horn from building /ant i lintel over new window at Corridor 0303 Clean caulk on brick below new window at Corridor 0303 CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB #96079 Page 2 4 Milo Fib IRemove tar on window and brick at Room No.0503 r _ R m (new)bolts and patch holes at electrical blank cover The installation of 6"X 6"Pressure treated beam at pathway is a possible code violation. If not removed than beam ould be safety striped or day-glow painted at path intersection. Remove caulk off brick at Room 0504 window mull center SOUTH ELEVATION(E)BUILDING Patch holes(new)in brick at elec.box for exhaust fan rt rovide finish coat of paint on Doors(5 1) Pr/ovide mortar joint fill at steel lintel installation nstall missing screw in Door hinge(5 1) Caulk around Door frame &sides of window at(5 1) WEST EVATION(E)BUILDING Patch masonry footing(damaged installing tar walk) EAST EVATION(E)BUILDING C an brick wall under stairs lean caulk off brick at window(Room 0507) Remove or re-install hanging wire at roof level jog SOUT LEVATION(C)BUILDING /clean ean chalk line off brick caulk off brick above light below louver WEST LEVATION(C)BUILDING Caulk around vent Install cover to conduit box CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Addition &Renovations Northampton High School Northampton, MA Prepared By: Robert LaMontagne KB#96079 EXTERIOR(Existing Building) EAST E VATION(D WING) lean all windows Y emove initials spray painted on brick nstall missing louvers eplace(2'X 3')louver in ground level e ove old bracket over 2'X 3'louver emove old pipe brackets on first course of brick Remove bolts and patch holes under window at Room 1407 e'place damaged brick(Damaged when cutting louver opening under window at Room 2408) aulk under window at Room 1407 emove nail in foundation wall above 5'X 5'Vent Install cover on 4" brass Drain EASEVATION(E WING) Clean brick(Masonry dust)at Main Level e-caulk inside corner of brick at northeast jog near Door No. 0403 /emove protruding bolts and patch holes at northeast wall near Door No. 0403 P"""it Door and frame No.0403 Install vision frame and glass in Door No. 0403 Install Aluminum Fascia at roof edge Remove excess caulk off brick near aluminum Door No. 0505 CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain, CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508)520-0856 NET— ow KAESTLE BOOS A_SSOCIATES,INC. ARCHITECTS September 6,2000 John A.Kaestle Mr. Richard Aquadro emeritus Aquadro & Cerruti, Inc. Texas Road Charles W.Boos P.O. Box 656 David W.King Northampton,MA 01061 Mark J.Weisman Michael J,Blessing Re: Addition&Renovations to Am'r Rusty Malik Northampton High School Michael J.McKeon Northampton MA KB#96079 Jeffery R.McElravy Dear Mr. Aquadro: Christopher M.Roof Richard F.Webb Enclosed is a Punch List of the Exterior of the Existing Building generated by my walk- thru on August 31, 2000. Please incorporate these with previously issued Punch Lists, Jamie L.DiPinto and advise Ms. Milikowski when you are ready for a re-inspection. Vincent R.Amrhein Traci H.Milikowski Very truly yours, Scott J.Mangiagli Terry A.McDonald John W.Juros Robert LaMontagne Lawrence P.Trim KAESTLE BOOS ASSOCIATES,INC. Scott D.Pellman RM:lk CONNECTICUT Enclosure 416 Slater Road P.O. Box 2590 c: Lawrence Fink (w/enc.) New Britain,CT 06050-2590 Joseph Misterka (w/enc.) Phone:(860)229-0361 William Letendre (w/enc.) Fax:(860)229-5303 Robert Aquadro (w/enc.) MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 Aail:kba®kba-architects.com Veb:www.kba-architects.com KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB#96079 Page 2 of 2 Install grilles and rubber base at casework,west. 1228 Uniform Storage Clean carpet at floor stops. Patch wall at electrical device. _ 1217actice C6mplete. 1216 Practice Clean carpet at floor stop. � Patch wall at data outlet. 1215 Practice { Patch wall at electrical devices. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)1520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Addition &Renovations Northampton High School Northampton, MA Prepared By: Traci H.Milikowski KB#96079 Partial Main Level Area B General Comments ' Remove covers from all ceiling mounted electrical devices. Cut in paint at h.m. frames/caulk joint. All doors to be reviewed as this typically occurs at most frames. Lam, Clean scuff marks,paint finish coat at h.m. doors and frames. Remove protective covers from all kick plates,mop plates, and other hardware on doors. c✓� Install silencers on all doors. 1212 Rand Remove plastic protective coating from light fixtures. r; Install markerboard,east. Clean slop sink, east. ,/Paint h.m. door frames/wall a nd scuffed door frames. Install rubber base,north. Finish paint outside corner,north wall. L11 Patch/paint wall below plastic laminate window stools. Patch/paint at all window trim,jambs and heads. Install blinds. Clean windows,install s creens. 1 Clean fabric at acoustical wall panel, south. +� Install grille doors on casework,west. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508) 520-9928 F: (508) 520-0856 t KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB#96079 Page 8 of 8 1110 Waiting V/ Install tackboard, east. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 t KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB#96079 Page 7 of 8 Storage Closets, south Locked at time of Punch List. Owner occupied. 1116 HCT Clean floor. Clean accessories. v Install lav guard and escutcheons at piping to sink. 1113 Exam Paint east wall at casework. Install modesty panel at sink in casework. L� �R,eplace broken lens on light fixture. �-//Clean rubber base. 11-L Cot ht fixtures. / Remove plastic covering from light 1J Clean scuff marks from floor. Patch wall at electrical outlet, south. 1112 Office Paint outside corners of north entrance. Install tackboard,west. Clean refrigerator. Install modesty panel at sink in casework. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB#96079 Page 6 of 8 i✓ Install missing ceiling tiles. Finish p aint west soffit. +� Finish paint guardrails, scuffed at west side. Clean all railings. Touch-up paint as required. Install device cover plate at east end of door pocket,pair doors 1103B. Clean rubber flooring and base, all treads and risers. 1103 Corridor JInstall remainin g rubber base. Paint overspray at railings on ramp/stair. V Remove debris, clean floor and base. i/ Install diffuser. Floor pattern? 111 Custodian Patch vet flooring at conduit penetration. 1118 Electrical Locked at time of Punch List. 1114 Exam I Install modesty panel at sink in casework. Adjust light switch cover. Clean rubber base north. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 r i KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB#96079 Page 5 of 8 aint wall at access panel,north. One light fixture not in operation. 1102 Corridor Install missing ceiling tiles. Clean v.c.t flooring and rubber base. F Adjust lens on light fixture, east end. Replace pair of doors 1105C,veneer is delaminated on corridor side. ,r Patch/paint wall at water cooler face panel,north. Paint wall below unit. Clean scuff marks, paint doors 1102. 1120 Emergency Electrical Locked at time of Punch List. 1106 Storage Repair wall at fintube,north. Remove nut from steel column,patch wall,north. Finish paint east wall high. finish paint exposed ductwork. Install floor stop in corridor at left hand door. 1107 Men's HCT 1108 Women's HCT Locked at time of Punch List. Sta' Al Replace ceiling tile near Gymnasium entrance doors. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB#96079 Page 4 of 8 Adjust sag in ceiling mounted cabinet unit heater. 0111 Aerobics "//Clean flooring. Installation incomplete at time of Punch List. ,/Patch holes in soffit, finish paint at north and east. Patch hole in mortar joint,low north wall. Clean entrance glass and hollow metal frames. Clean west wall near switch. Install tackboards. L/Finish paint exposed ductwork. ,/Paint railing wall brackets, east. Finish stain wood railing. Clean mirrors. Scratch in third mirror from left. Damage at butt joint between first and second panel. Adjust pendant light fixture mounting,north. One light fixture not in operation. stall rubber flooring at south vestibule area. L// Patch wall at water cooler face panel. �-' Fill hole (smoke resistant) at pipe penetration south wall. Patch hole in mortar joint,high south wall. . 0112 At letic Storage Finish installation of rubber mat flooring and rubber base. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860) 229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB#96079 Page 3 of 8 Paint wall/door frame, south. Team Room Storage Install closer on door to storage room. (verify hardware set) Remove wall tie,patch north wall. Finish paint north wall. ` v Light fixture did not operate. Install sprinkler. 1117 HCT Clean ceramic tile floor and base. Clean accessories. V Repair ceramic tile base,northwest corner. L1 Install lav guard and escutcheons at piping to sink. Finish ceramic tile base at water closet. jRemove wire hanging from light fixture. Paint exposed concrete block, west wall. Stair A4 (Lower) ✓ Clean rubber flooring and base. _Paint h.m. frames. (',,/Install cover plate or patch wall, west. Paint at h.m. frames/wall. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508) 520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Northampton High School KB#96079 Page 2 of 8 i Install vented rubber base at safety padding,north and south. Install all wall mounted electrical devices. -/Install aluminum thresholds at all doors. /Trim blue paint at head of translucent wall panels and steel, all. 0 Paint exposed relieving angle in 4 bays of split-rib concrete block panels,north. _J_/Patch wall at lighting controls,north. if Mismatched veneers on door pairs 1105A and 1105B. Stair A4 Main /Clean rubber flooring and base. Clean doors. lean north wall at stair. Paint at north rail wall brackets. Stair A5 Not included in Punch List 1104 Visiting Team Room Install glazing in door. stall wood bench,north. - Install hooks,north. Paint exposed block wall, south. `Caulk at access panel, east. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 31, 2000 Addition&Renovations Northampton High School Northampton,MA Prepared By: Traci H. Milikowski KB#96079 Main Level Area A Partial Lower Level Area A General Comments ✓ Remove covers from all ceiling mounted electrical devices. - ,//Cut in P aint at h.m. frames/caulk joint. All doors to be reviewed as this typically occurs at most frames. Clean scuff marks,paint finish coat at h.m. doors and frames. ✓' Remove protective covers from all kick plates,mop plates, and other hardware on doors. Install silencers on all doors. Install multiple signage with top sign no higher than 60" a.f.f. to center. Install backplates on all glass mounted signage. • Stairs A2 and A3 were incomplete at time of Punch List. 1105 Gymnasium L/ Install bleachers. Install walk-draw curtain. /Clean backstops. Adjust safety padding at bottom of backboard,north backstop. —/, Operation of sidecourt backstops: back or forward fold? Refer to previous correspondence regarding conflict with main court volleyball. ✓ Remove protective coverings, final clean wood floor. ✓/Several pin holes were observed in open portions of floor, southeast blue band. Repair all. -7/Paint wood blocking at backstop brackets,north and south. /Install wood trim at safety padding. (In progress at time of Punch List.) CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860) 229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES,INC. A R C H I T E C T S September 5, 2000 John A. Kaestle Mr.Richard Aquadro emeritus Aquadro& Cerruti, Inc. Texas Road Charles W.Boos P.O. Box 656 David W.King Northampton, MA 01061 Mark J.Weisman Michael J.Blessing Re: Addition&Renovations to Am'r Rusty Malik 'Northampton High School Michael J.McKeon Northampton MA KB#96079 Jeffery R.McElravy Dear Mr. Aquadro: Christopher M.Roof Richard F.Webb Enclosed is a Punch List of Main Level Area A and Partial Main Level Area B generated by my walk-thru on August 31, 2000. Please incorporate these with previously issued Jamie L. Di Pinto Punch Lists, and advise me when you are ready for a re-inspection. Vincent R.Amrhein Traci H.Milikowski Very truly yours, Scott J.Mangiagli Terry A.McDonald John W.Juros Traci H.Milikowski,RA Lawrence P.Trim Associate Scott D.Pellman KAESTLE BOOS ASSOCIATES,INC. THM:lk CONNECTICUT 416 Slater Road Enclosure P.O.Box 2590 New Britain,CT 06050-2590 e: Lawrence Fink(w/enc.) Phone:(860)229-0361 Joseph Misterka (w/enc.) Fax:(860)229-5303 William Letendre (w/enc.) Robert Aquadro (w/enc.) MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 E-Mail:kba®kba-architects.com Web:www.kba-architects.com KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 14, 2000 Addition &Renovations to Northampton High School Northampton,MA KB 496079 Page 2 of 2 Room No. 1303 Clean scuffs on doorjamb Install missing ceiling tiles Room No. 1304 V Repair lower west wall, bubble in sheetrock Clean scuffs from lower east wall and rubber base Room No. 1305 epair gouge in door Adjust light sensor lean glue from top of wire mold on east side of room. Remove plastic from light fixtures Cl t in paint at corridor wall near door om No. 1307 Clean light fixture lens Replace broken light fixture lens, adjust fixture CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Addition &Renovations to Northampton High School Northampton,MA Prepared By: Robert Lamontagne KB#96079 Main Level Area"C" General cleaning of doors, floors and windows, casework oom 1302 Media Center /Entry doors from corridor,touch up paint on inside frame �! v' lean glue off of backpack cubby on east side of entry n-part off of top of backpack cubby on west side of entry J { 2 Install television monitors over nt —and Room 1307 lean scuffs off of Northwest wall of Head End Room 1303 (Media center side) Repair dings in wall at corner of computer area :�/Remove plastic from light fixtures ,Remove blue plastic from fire strobe device on Northwest side of computer area an smudge on ceiling grid over Northwest side of computer area Touch up paint on door frame to Room No. 1304 Touch up paint on window frame to Room No. 1305 Clean scuff on west wall below three cut out for television on west wall lean scuffs on west wall corner ouch up paint on lower wall, southeast alcove — Touch up paint on door frame and window frame to Room 1306 / Remove blue paint on wall and repair dings on wall to the west of door to Room No. 1306 Replace damaged tile in southwest alcove area nstall window blinds on south side I stall rubber base on pilasters on south side of space Clean scuffs off of south eastern mot pilaster can scuffs on wall of east wall behind circulation desk nstall rubber base on underside of circulation desk,north side near column Amish installing rubber base on the outside of the circulation desk,typical around columns Repair laminate on light beige section of south side of circulation desk(outside face,near column) hipped Clean scuffs on laminate on base of south side of circulation desk Install shelves'in display kiosks and clean Center ceiling over existing shelving on south side of Media Center, adjust misaligned ceiling tiles CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 Ap- ski'�Y---•°�u'4FbT.`.�iffiti4151iim^'.� KAESTLE BOOS ASSO_CIATES,INC. ARCHITECTS September 1, 2000 John A.Kaestle Mr. Robert Aquadro emeritus Aquadro & Cerruti,Inc. Texas Road Charles W.Boos P.O. Box 656 David W.King Northampton, MA 01061 Mark J.Weisman Michael J.Blessing Re: Addition &Renovations to Am'r Rusty Malik Northampton High School Northampton MA Michael J.McKeon KB 496079 Jeffery R.McElravy Dear Mr. Aquadro: Christopher M.Roof Richard F.Webb Pursuant to my visit to observe work on August 29, 2000, enclosed is the Punch List. Jamie L.DiPinto Please advise me when this work is ready for a re-inspection. Vincent R.Amrhein Traci H.Milikowski Very truly yours, Scott J.Mangiagh Terry A.McDonald John W.Juros Robert LaMontagne Lawrence P.Trim KAESTLE BOOS ASSOCIATES,INC. Scott D.Pellman RL:gh CONNECTICUT Enclosure 416 Slater Road P.O.Box 2590 c: Joseph Misterka(w/enc.) New Britain,CT 06050-2590 Lawrence Fink(w/enc.) Phone:(860)229-0361 William Letendre (w/enc.) Fax:(860)229-5303 MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 -Mail:kba @kba-architects.com Web:www.kba-architects.com \\NTSERVER2\data\Northampton\2000\High School\Ca\Punchlisu\aquadro0831009punchlist.doc r KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29,2000 Addition and Renovations KB#96079 Northampton High School Page 4 4 �nstall railings at stairs Install flashing over concrete band EAST ELEVATION (A)W G Clean doors ZInstall electrical box cover Clean Caulk off brick over aluminum doors CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Stater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 t KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Addition and Renovations KB 496079 Northampton High School Page 3,of 4 V/ ;Clean excess caulk on brick over storefront doors /,,Clean all windowsills aluminum Paint double doors at Receiving Dock rfnstall caulking under lower EIFS entire west wing V/ Caulk around "Coiling.Door Jamb" r Replace weather striping at top of roll up door(does not cover opening) iZ r" Paint galvanized jambs at roll up doors stall railings at Receiving Dock and Stairs Caulk first course of brick where meets dock SOIJTI1I ELEVATION (A)WING Clean al{ windows Paint all lintels aulk under all precast sills Install scupper and cover at southwest elevation Drain(?) has to be extended and piped to ground in Brick wall near wall with ground face block — After correcting drain(see above),clean rust off building XCaulk all ground face block under Lower EIFS Cut excess flashing over lower EIFS Clean ground face block at south east elevation near stair CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 F KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Addition and Renovations K13#96079 Northampton High School Page 2 of 4 NORTH ELEVATION (A)WING Tighten lever handles on aluminum storefront entrance —12— Clean aluminum storefront doors _ Paint Steel Lintel NORTH WEST ELEVATION (A)WING (at entrance door jog) Remove dripped caulk from brick WEST ELEVATION (A WINO —L/Install missing roof ladders ✓ h stall missing hinge screw at single door oor& Frame No. 0103B needs re-painting Clean ground face block under window le' Finish aluminum fascia on roof over doors /Cover missing for Knox Box --L/— C,Iean Knox Box Clean aluminum storefront doors y Paint lintel over aluminum doors Paint lintels over all windows CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road, P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 r KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29,2000 Addition and Renovations Northampton High School Northampton, MA Prepared By: Robert LaMontagne K13496079 NORTH ELEVATION (13) WING Railings at exterior stairs and ramp at north end of returning wall must conform to "Guardrail" (T-6") height - l/ eismic joint cover joint at EIFS is missing 1 Clean caulking off EIFS near scupper WEST ELEVATION (P) WING /Cut off exposed ties in brick over Double Doors Cut off exposed flashing under precast sill at main level windows Cut off and caulk excess flashing over louvers r' Cut off and caulk excess flashing over lintels under ground face block L/ Clean aluminum louvers Paint Steel Lintels at all windows, louvers& doors ,Replace hinges on both double doors (have to be galvanized). Note: there is a missing set of hinges Replace dented cap on "door handle blank" /Doors and frames need an a finish coat of paint at exterior CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 f KAI:STI I: !J008 All ,I g I I F 1;-1 'S August 31,2000 )<i , K,.,t,,li„ Mr. Robert Aquadro t.rt,<t ttll. Aquadro & Cerruti, Inc. Texas Road hai1,�\A bu(,, P.O. Box 656 1)3vid W.Kink Northampton, MA 01061 Mal'k J,wc'!Sman ttilir I,ael i' Re' Addition & Renovations to Ani r )r_t I} tiv.,i k Northampton high School t,ael I M.rt�„rt Northampton MA n�ti, KB#96079 Dear Mr. Aquadro: Iiit i,,trd 1.Vv(.hh Pursuant to my visit to observe work on August 29, 2000, enclosed is the Punch List. i<,,,,,t i. ui1`111 t, Please advise me when this work is ready fora re-inspection. `Vint eul k.Arrrhruv Very truly yours, letrrc r�.-Mt I irxialti Huhn vv,.it�t„� Robert LaMontagne t.�U tt nt t,I� oiin KAESTLE BOOS ASSOCIATES,INC. ��t txl a r.•n.„�,�� RL:gh < ()NN[( nl U! Enclosure 41 h Y,iwr Road 13() box 21,90 c: Joseph Misterka(w/enc.) New ariiain, c 1 060':,0 Lawrence Fink(w/enc.) Pht�t,t t)sl,oi ,,t1 Oit,l William Letendre (w/enc.) 124 l,noy(,SlreH tiuow 21 I ranklin,MA,1)21)51” Phoit(t:508) c12i1 y9?t't t ax:(508)`,20 0856 Mail:kba@kha att hilet Is.c om Web:www.kba-art hitet C,.t o!" \\N'FSERVBR2\data\Northampton\2000\I{igh SchoolT a\Punchlists\aquadro0831009punch list.doc KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Northampton High School KB#96079 Page 9 of 9 Install missing ceiling tile. Fix shoe at wide pilaster of handicapped stall. Clean wall at sinks. Paint door frame, install silencers. Grout floor tile at door frame/threshold. Stair Al,Lower Level only i/Al Install tackboard. L-, Patch wall at electrical outlet, south. t/ Paint at door frame/wall,Door 0101A. Paint at stringer/soffit. Paint soffit at recessed can light fixture. Z0135 assage Install sprinkler head in soffit. Replace damaged ceiling tile. Adjust ceiling tiles in northeast corner. Caulk at elevator entrance frame. Install musing ceiling tile. 0110 Elevator achine Room Complete. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Northampton High School KB#96079 Page 8 of 9 stall tackboards. Clean dirt,north and south walls. Install missing ceiling tiles. XFinish paint above door 0109. 0108 en Toilet Clean accessories. dean ceramic tile floor and base. Grout is stained. / Clean partitions. ✓ Clean wall at urinals. /eplace broken lens in recessed light fixture. Paint access doors,west wall. Reinstall partition mounted accessories according to Contract Documents. y 70109 omen Toilet Clean accessories. Clean ceramic tile floor and base. Grout is stained. Clean partitions. aint access doors,east wall. Reinstall partition mounted accessories according to Contract Documents: Install large access door,west wall. Replace damaged ceiling tiles. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. ]PUNCH LIST August 29, 2000 Northampton High School KB#96079 Page 7,,of 9 nstall lav guard at sink. Clean wall near sink. Install mop/kick plate on door. (Confirm hardware set.) 01333 Men Toilet a/ Clean all toilet accessories. Finish electrical installation at sink. Install lav guard at sink. 4. Clean west wall. Install mop/kick plate on door. (Confirm hardware set.) Install sprinkler head. 0104 Vestibule Incomplete. 0106 Storage Clean/paint scuff marks, east wall. Install rubber base,north wall. Replace ceiling ti es near light fixture. 0107 Electrical Not reviewed. t ridor ash and wax floor. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Northampton High School KB#96079 Page 6 of 9 0127 Can Wash /Replace damaged ceiling tiles. Paint wall at exposed piping,west. 0103 orridor Adjust ceiling tile at sprinkler head, south. Adjust sag in ceiling mounted cabinet heater. Clean cover. Replace damaged ceiling tile adjacent to exterior pair of doors. t7 Paint interior and exterior finish coat at exterior pair of doors. Remove graffiti. Yclean scuff marks, west wall. Replace damaged ceiling tile near toilet/locker room. Repair caulk at stool of north window. Clean all window stools. 0131 -ocker 7 Paint steel angle bench supports. Stain wood bench. Install sloped tops,locks,nameplates on metal lockers. Patch wall at electrical device above Door 0130. 0130 Women Toilet Clean all toilet accessories. L/ Finish electrical installation at sink. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Northampton High School KB#96079 Page 5 9s.9 Replace damaged ceiling tile near ref/frz area. Relocate hanging pot rack at northwest. Install per Documents. (Refer to Zaralban Punch List.) 0116 Dry Storage _ Door requires knurled outside lever. 0129 Office Install tackboard. 0124 Receiving Paint jambs at coiling door. Cover of coiling door is scratched and dented. Repair/paint hollow metal door. Touch up paint between wall and h.m. frames of doors and window. 0125 `ce Install tackboard. Replace damaged ceiling tile. Clean walls or paint. 01261tecycle Paint wall at exposed piping, north. —1/4 Install missing ceiling tiles. Install electrical device or cover plate at north wall. Install escutcheon at sprinkler head. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F. (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Northampton High School KB#96079 Page 4 of 9 lean coiling door and frame. ,/Install missing ceiling tiles. +-'' Relocate sprinkler head to center of pad, adjacent to coiling door. —Z Paint/repair scuffmarks in soffits. V Install electrical devices in ceiling. Clean wall at doors,north. Install rubber base at all low walls. pry Caulk at joint between plastic laminate cap and gypsum board. l Install electrical devices at all low walls. 0118 Dishwash Clean coiling door and frame. Secure chain hoist to wall. Install missing ceiling tiles. 0119 Storage. Complete. Z 0115 Ki hen djust ceiling tiles in passage adjacent to Office. Paint block at north wall. eplace ceiling tile at diffuser,northwest. Paint access panel northwest corner. Replace ceiling tile with handprints,west center, and any others. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29, 2000 Northampton High School KB#96079 Page 3 of 9 Install missing ceiling tile at south center. Clean water coolers at north wall. Paint soffits at entrance to Servery. _j,,�'�Adjust light switch cover at coiling doors,north wall. / Patch wall at electrical device adjacent to exterior doors, east wall. —1/- Clean exterior aluminum doors and frames. Repair scratches. /-Repair caulk joint at head of aluminum doors. tall missing fin tube radiation covers. Y w. stall snap trim at southeast wmdo an all window stools. Replace ceiling tile at sprinkler head,west adjacent to Faculty Dining. 0123 assage Clean wall, southeast. stall tackboards. Patch wall at access panel,north wall. 0126 Custodian Complete 011 Servery Clean floor and base. Adjust recessed light fixtures to fit in grid. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KA.ESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29,2000 Northampton High School KB#96079 Page 2 of 9 0121 culty Dining 7Clean casework inside and out,north elevation. Install knee panel at sink. 7 Caulk at wall/counter and full height backsplash. Install refrigerator. Clean floor tile at casework area. Repair ceiling grid at corner of north column. —�3(paint soffit at folding partition track. Install switch cover at south column. JiV-""Folding partition was closed. Vinyl needs cleaning at first panel, clean all panels as required. Caulk both sides of folding partition jambs, and repair vinyl edge. Exposed edge unacceptable. Relocate all sprinkler heads not located in center of pad. Adjust recessed light fixtures to fit in grid. 0122 SA-rage Patch wall at electrical outlet,north wall. Paint access panel, south wall. 0120 Cafeteria 7Clean all pendant light fixtures, all surfaces. 1f Adjust electrical device cover at soffit with t.v.bracket. Lr Adjust electrical device cover at southwest column. JRepair/paint scuff marks at southeast soffit. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P; (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 29,2000 Addition&Renovations Northampton High School Northampton,MA Prepared By: Traci H. Milikowski KB#96079 Lower Level Area A General Comments Remove covers from all ceiling mounted electrical devices. Cut in paint at h.m. frames/caulk joint. All doors to be reviewed as this typically occurs at most frames. Remove protective covers from all kick plates,mop plates and other hardware on doors. L-/Install silencers on all doors. Clean rubber base. Clean all resinous flooring and integral base. Patch or clean paint at top edge of resinous base. Touch up paint at all hollow metal doors and frames. Most doors have scuffmarks. Exterior doors require finish coat. Replace all damaged ceiling tiles. • Typical at Cafeteria and Faculty Dining: J:,I Cut in paint at columns to wall and columns to soffits. Touch up paint at column/wall and caulk joints. • Windows are not included in this punch list; review frames for scratches. All windows are yet to be cleaned, including removal of adhesives, and screens installed. • Refer to separate Punch List, issued by Zaralban&Associates, for all food service equipment. • Stairs Al, A2, and A3 were incomplete at time of Punch List. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508) 520-0856 KAESTLE BOOS ASSO_CIATES,INC,. A R C H LT E C T S August 30, 2000 John A. Kaestle Mr. Richard Aquadro emeritus Aquadro & Cerruti, Inc. Texas Road Charles W.Boos P.O. Box 656 David W.King Northampton, MA 01061 Mark J.Weisman Michael J.Blessing Re: Addition &Renovations to Am'r Rusty Malik Northampton High School Michael J.McKeon Northampton MA KB#96079 Jeffery R.McElravy Christopher M.Roof Dear Mr. Aquadro: Richard F.Webb Enclosed is a Punch List of Lower Level Area A generated by my walk-thru on August 29, 2000. Please incorporate this with previously issued Punch Lists, and advise me Jamie L.DiPinto when you are ready for a re-inspection. Vincent R.Amrhein Traci H.Milikowski Very truly yours, Scott J.Mangiagh Terry A.McDonald John W.Juros Lawrence P.Trim Traci H. Milikowski, RA Associate Scott D.Pellman KAESTLE BOOS ASSOCIATES,INC. THM:lk CONNECTICUT 416 Slater Road Enclosure P.O. Box 2590 New Britain,CT 06050-2590 c: Lawrence Fink(w/enc.) Phone:(860)229-0361 Joseph Misterka(w/enc.) Fax:(860)229-5303 William Letendre(w/enc.) Robert Aquadro (w/enc.) MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 Mail:kba®kba-architects.com 'deb:www.kba-architects.com KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB#96079 Page 7 of 7 Clean adhesive at existing glazed block base adjacent to Door 0511 C. Paint reveal at wood cap, both sides, black. (review detail) Clean exterior doors,repair weatherstripping. (Exterior surface not observed, based on other exterior — doors, assume requires finish coat of paint on doors and frame.) Install all electrical device cover plates on north, south and west walls. t ` Install missing ceiling tile. r Note: Control Room locked at time of punch list. 0514 Storage .Adjust ceiling the at east wall. Install sprinkler. 0513 Audio L/Install diffuser. Install sprinkler. ` Paint over graffiti at north wall, 0512 Voice Over Install diffuser. Install sprinkler. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 6 of 7 Repair v.c.t. at island casework, south. 0518 Electrical Workroom Install ceiling the at south wall. Clean adhesive from existing glazed base at electrical room, or install new rubber base at partial south and west walls. Clean/paint at electrical room door. Touch-up paint at west wall adjacent to electrical room. Install louvers at gravity dampers. Touch-up paint at west wall rubber base. Replace damaged ceiling tile at window. Clean paint on ceiling grid wall trim, northeast. 0516 raphics Vacuum carpet. + Unit ventilator was in operation, appears to have a rattle. Adjust ceiling tiles at pendant light fixture mounting plates. Install louvers at gravity dampers. i Adjust all base cabinet doors. Remove tape from vertical wiremold, south wall. 0511 TV Studio c. Clean rubber flooring and base at ramp and landings. Clean steel stair treads. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590, New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB# 96079 Page S,bf 7 Patch wall at electrical device above toilet room door,north wall. 0506 HCT Clean ceramic tile floor and base. Grout is stained at center of room. __L�ZX/Replace cracked tiles in floor field. Install handicapped lavatory guard. 0519 Modular Technology Caulk at base cabinet and countertop, casework at west wall. f 1`/Paint at vertical wiremold, west wall near window. can reducer strip. Clean epoxy resin countertops and sink. Cover exposed particle board edge below skirt at sink, east wall. r' Recaulk at base of door frame, east wall. Replace water damaged ceiling the at southeast corner. �F __L-Z Patch hole in wall at south soffit, east of center. Adjust ceiling tiles at pendant light fixture mounting plates. _ 11-/Clean/repaint soffit at folding partition. Install louvers at gravity dampers. Install louvers at ceiling mounted cabinet unit heaters. 'Install insulation at exposed ductwork at ceiling mounted cabinet unit heaters. Adjust devices in wiremold at island casework. v CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB# 96079 Page 4 of 7 0504 Multi-Purpose Vinyl gasket exposed at unit ventilator. Repair scratch/touch-up paint at metal shelving unit. /Install rubber base at exposed wood base,north face of plastic laminate casework, east wall Adjust pendant light fixture baffle. Clean rubber base, south wall. V/ Clean tall cabinet doors. r e Clean paper towel dispenser. Install rubber base at support legs of computer counter. Cut-in paint at h.m. frames/caulk. 0524 Observation Clean glass. Adjust ceiling tile at 45° angled wall. Light fixture did not turn on. Check switch or missing bulb. 0505 early Childhood Remove tape from wiremold, east wall. Clean reducer strip at carpet/v.c.t. L Repair missing portion of wall trim at ceiling grid, north wall. Install refrigerator. Caulk at tall cabinet, north wall. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 r KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB#96079 Page 3 of 7 Install rubber base at lower floor area. T Clean concrete floor and steel stair. Repaint as required. w / ouch up paint at scratches on double doors. Reinstall lever lockset on double doors with knurling/key side on Project Lab side. (Currently installed with lock on storage side.) ` 0506 HCT Clean tile floor and base. Clean fixtures and accessories. install handicapped lavatory guard. Install escutcheon at sprinkler head. 0503 Food Lab t/'Resinous floor and base under repair during punch list walk-through. (Issue previously addressed in separate Field Observation Report.) Install door at storage room. Install escutcheon at sprinkler head, southeast. Clean markerboard. Remove label at window solid panel. ..nstall cap at low wall. Clean doors and hardware. PP damaged Repair d support leg at computer counter. P g Touch-up paint at resinous base/door frames. T CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB# 96079 Page 2 of 7 _ Galvanizing is damaged at wall mounted handrail, repair rusted surface. Finish paint. Clean paint from laminate countertop, east wall. 1/ j�Repaint room side of Door 0507A (scuff marks). 7Clean door, touch up paint at Door 0520. 0520 Finish Room Iylstall missing ceiling tile. Clean floor. ouch up paint at h.m. window frame. Clean sink. Install rubber base. Install escutcheon at sprinkler. 0509 Department Office f Clean rubber base and floor. ' einstall rubber base at door frame, both sides, at north wall. Return to jamb. atch wall at electrical devices, south wall. Clean door and glass. 1 Cut-in paint at h.m,window frame. 0521 Storage Paint low wall at loading area,north. Touch up paint at interior of exterior door. Paint exterior finish coat at exterior door and frame. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Stater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P. (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Addition&Renovations Northampton High School Northampton,MA Prepared By: Traci H. Milikowski KB#96079 Lower Level Area E General Comments • Windows are not included in this punch list; however, note that several frames have been scratched, i.e. at wide mullion covers, true mullions, sash, etc. All windows are yet to be cleaned, including removal of adhesives, and screens installed. • Corridors are not included in this punch list. Installation of rubber and painted base has been addressed in a Z vious Field Observation Report. Locker installation is incomplete. Floors have not been cleaned. Adjust all devices in wiremold. Remove covers from all ceiling mounted electrical devices. z Remove protective plastic from all light fixtures. 1r� t�Cut in paint at h.m. frames/caulk joint. All doors to be reviewed as this typically occurs at most frames. ky Install louvers at all gravity dampers. 0507 Project Lab Clean floor. I stall wire cages at all emergency lighting fixtures. Adjust devices in wiremold at south wall. Paint steel column at window,west wall. ✓install louver at gravity damper, west wall. Clean panic device at exterior door. :i/Paint exterior finish coat at exterior door and frame. Finish paint interior of door around panic device. Plug holes at bottom rail of exterior guardrail. Finish paint. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 i ai me KAESTLE BOOS ASSOCIATES,INC. ARCHITECTS August 16, 2000 John A.Kaestle Mr.Robert Aquadro emeritus Aquadro & Cerruti, Inc. Texas Road Charles W.Boos P.O. Box 656 David W.King Northampton, MA 01061 Mark J.Weisman Michael J.Blessing Re: Addition &Renovations to Am"r Rusty Malik Northampton High School Northampton MA Michael J.McKeon I{B#96079 Jeffery R.McElravy Dear Mr. Aquadro: Christopher M.Roof Richard F.Webb Enclosed is an additional Punch List generated by my walk-thru on August 15, 2000. Please incorporate this with previously issued Punch Lists, and advise me when you are Jamie L.DiPinto ready for a re-inspection. Vincent R.Amrhein Traci H.Milikowski Very truly yours, Scott).Mangiagli Terry A.McDonald John W.Juros Traci H. Milikowski Lawrence P.Trim Associate Scott D.Pellman KAESTLE BOOS ASSOCIATES,INC. THM:lk CONNECTICUT 416 Slater Road Enclosure P.O.Box 2590 New Britain,CT 06050-2590 c: Lawrence Fink(w/enc.) Phone:(860)229-0361 Joseph Misterka(w/enc.) Fax:(860)229-5303 William Letendre (w/enc.) MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 -Mail:kba @kba-architects.com Web:www.kba-architects.com REMEMNSWeEksm KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB# 96079 Page 13 of 13 Repair gouge in wall at south wall of classroom. J! /evel doors on casework. Clean scuffs on north wall. 1407 Cl sroom I fall door stop stall missing ceiling tile pair Unit ventilator on left side where butts against bookcase unit. ouch up painted existing chalk tray. Replace poorly installed whiteboard. Seaming problem. 1405 Vestibule L,//General floor cleaning required of floors and doors. /,Remove scuffs from storefront to Reception. L//Clean scuffs from fascia at administration wall. Clean register at ceiling. Touch up paint at storefront doors to Corridor 1402. Install recessed mat. 14,0/3--Corridor V In Main Level D,the top of the new glazed block needs more and neater grouting 7 Electrical box cover needs adjustment outisde Office 1438 CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB# 96079 Page 12 of 3 Install door stop for toilet room door and storage closet door. F' ish door edge on door to toilet room. Replace discolored ceiling tiles. 1409 all Classroom - 7I stall door stop. epair bump in wall on North side. nstall missing ceiling tile. eneral cleaning of floors. Repair window frame on operable window, left corner. lean unit ventilator. pair grille at base of unit ventilator. Touch up paint on door frame right side. 1408 C ssroom Replaced damaged ceiling tile lean floors. Finish wood trim at window. VReplace ceiling tiles with water damage. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB#96079 Page 11 of 13 141 IDF Add blank plate to abandoned electrical device in south east corner. finish ceiling installation. emove plastic from light fixtures. General cleaning of floors. fAdd ushing to 4" pipes. k hole in wall at coverplate near door. ire rating in around duct in telephone switch gear room 1411 oilet Clean window. Install trim at light fixture. Install mirror. Replace damaged ceiling tiles. 1410 p d Adj.Counselor Paint walls where patched. Remove blue protective tape from wiremold. Clean unit ventilator. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 10 of 13 1420 Custodian /"'C' lean sink. Clean door. Adjust cabinets i� Adjust Unit 64 cabinets 1414 Seminar/Conf Repair gasket at window. Repair header at window. Clean ceiling grid at north east corner. Adjust light fixtures so there are no gaps and fixtures are level. i Clean blank cover plates of stain. Replace discolored ceiling tile in north west corner. L/ Install missing ceiling tile. �J stall door stop. Clean unit ventilator. Repair wood door jambs. Adjust door closer so if does not close on its own. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 9 of 13 1425 Adjust closer on Door No. 1425B, closes too fast Silencers missing on Door No. 1425A i/ Missing Butt screw and latching speed is too fast 1422 Ge eral Comp.Lab#1 Caulk window. Clean carpet and light fixtures. d rubber base to window wall under counters. , stall missing ceiling tiles. place damaged ceiling tile,damaged and scored. epair broken exterior window. Add glass and lockset to door from corridor 1402. :'/Repair emedial Classroom gouges in wall. Caulk windows. �( Touch up wall paint. Install door stop. 1/ Touch up paint on door frame to Rm 1423. General cleaning of floor. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 i KA.ESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 8 of 13 1427 Assistant Principal C ulk window and paint sill. Finish ceiling installation at window pocket recess. CJ C1 an scuffs off side walls, east and west. air dent m wall from latch side of door. Top of door rubs 1426 eception nstall electrical device on South wall. uch up paint on door frame left side (to corridor). Clean scuffs on walls. V/�epair gauges on North wall. C lk windows and paint sills. emove plastic from light fixtures. I stall speaker. Finish ceiling tile installation at window pocket. Terminate cabling under worksurface as required. Close up wiremold under desk. Recut ceiling tile at door to corridor,unacceptable cut. Sprinkler head needs height adjustment CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O. Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 7 of 13 Install handicap lavatory guard. hange blank in ceiling to a finish blank Ceiling pads in entire area are not seating as per revealed pads 1429 Passage Install missing rubber base to left of door to Rrn 1428. _Z/"Paint blank plate on wall in addition to blank plate in alcove ceiling near storage closet. tom'' Install glass in door to corridor. ✓ Paint wall near casework near alcove. /eplace ceiling the at sprinkler head in front of mailboxes. Bad cut.. Touch up paint at wing walls near sink, and outside corners. Repair gouges in wall to left of casework in copy area. L.vel cabinet doors, second pair from right side. Rectify wire in corner from ceiling. 1428 Principal C ulk window. Paint sill Remove scuffs from wall. Remove plastic from light fixtures. Doors to the casework with sink on north wall,need adjustment CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES;INC. PUNCH LIST August 15, 2000 Northampton High School KB# 96079 Page 6 of 13 1431 Conference ;,Install door stops,Repair dent in wall behind door. Remove scuffs from west wall. Clean floor, specifically HVAC shaft recess. /Move cables visible in ceiling at North East corner. Caulk windows l/ ouch up scratched paint at left side of header at window. Last cut of ceiling tiles at North end of room unacceptable. �'ust light fixtures to eliminate gaps between lengths. Touch up painted baseboards. round wire visible on light fixture, South east corner. place missing screws on door butt hinges. Adjust ceiling tiles, generally. Suspended light fixtures have to be dropped down, as they are pushing up the revealed ceiling pads 1430 Toilet Install door stop. ' stall mirror,over sink. Clean floor. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB#96079 Page 5 of 13 l ,/ Inst 1-door stop. can scuffs on base. The end 4'-0" at the south wall of the ceiling in the Life Skills Room No. 1436 needs to be straightened. (Cut one ceiling pad and move over entire row approximately 3/8") !� Sprinkler head is not in the center of one of the pads V' /Cabinet doors on Casework Unit on the south wall needs alignment adjustment, hinge adjustment so doors will close. 1435 Life Skills V/ Fix door stop,remove backing. Remove tape on door frame. f aint windowsill. nstall missing ceiling tiles. stall electrical device over Toilet Room door. o up washer and dryer. Add cover plates to receptacles at casework. 1434 Storage /n stall door stop. Ceiling grid needs adjustment as the ceiling pad is not sitting entirely on the grid CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 a KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB#96079 Page 4 of 13 1438 F culty Office Remove marker on wall at door frame inside room. 'V Complete unit ventilator installation. 7 Ftall missing ceiling tiles. x ceiling soffit. Repair wall at northeast corner of room. 7Repair mall Classroom#3 bumps in north wall. Install sprinkler escutcheons. Paint window sill. Clean unit ventilator. i� emove plastic from light fixtures. Repair soffit at window pocket. I:ynstall electrical device at wall or plate if not using. nstall door stop. 1436 Storage epair north walls with water damage. Replace ceiling tiles with water damage. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 3 of 13 1450 Electric plug on the southeast wall needs adjustment,does not cover hole 1446 Large nick in Door No. 1446 - 1 Silencers missing in door frame 1443 Silencers missing on double doors into Passage 1443 1442 Conference !� Install door stop. Y Remove plastic from light fixtures. ✓' Install glass in door. General cleaning, including light fixtures. 1441 F culty Workroom Install refrigerator. �/Replace ceiling tile at sprinkler head. 1439 1440 H.C.T. stall handicap lavatory guard. Replace ceiling tile at sprinkler head. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 2 of 13 L Ceramic tile base cap is not complete in back of toilet Door No. 1464 needs adjustment(rubs on strike side) Metal Frame at Door No. 1464 needs to be caulked at but side 1461 L/ Door No. 1461 missing butt screw Screws missing at top plate 1455 `C Ceiling grid bent,west wall,next to diffuser a Adjust cover of eyeball light over tack board @ south wall 1454 //Patch hole at the top of the wall 7 ,6 ,fioor No. 1454 from Corridor needs adjustment(it rubs) Patch side of light switch Door at 1456 rubs 7//"Door No. 1451 rubs,needs adjustment CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Addition&Renovations Northampton High School Northampton,MA Prepared By: Susan Sclafani KB#96079 Main Level Area D General Comments • Corridors are not included in this punch list. Installation of rubber and painted base has been addressed in a pre�ious Field Observation Report. Locker installation is incomplete. Floors have not been cjeaned. Adjust all devices in wiremold. General cleaning required, including light fixtures.. Ll ;Remove protective plastic from all light fixtures. }' //9 Cut in paint at h.m. frames/caulk joint. All doors to be reviewed as this typically occurs at most frames. • The following rooms are not ready for punch list. 1424 Health Coordinator 1419 Boy's Toilet 1433 1465 Window handle needs to be tightened(very loose) 1464/H.C.T. nstall emergency call button. nstall missing cover plate. Repair hole under sink. atch around toilet escutcheon. _ Install missing ceiling tile. Touch up paint on door frame. Cleaning of floor. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB# 96079 Page 6 of 6 17,chool Store Install receptacle plate at casework. Replaced water damaged ceiling tile 1523 General Classroom L.-' Remove letters from door(Audio Visual Center) Install missing ceiling tiles. L-''install door stop. 1524 General Classroom "° Install door stops Install fresh air intake grille louver at gravity damper. Remove letters from door(Faculty Library) CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 1' KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB#96079 Page 5 of 6 1517 SPED Alt Learning t Y ouch up paint at doorframe. stall missing ceiling tiles. 0 I Install unit ventilator face panel. ` Remove blue tape from wiremold !Touch up soffit at window pocket. _ Touch up outside corner wall Install fresh air intake grille louver at gravity damper. Replace ceiling pad at north wall, second row 1518 Time Out i.J Install missing ceiling tiles. ,Install glass in door. R/ Install door stop. Clean&paint header at window pocket. 1519 Book Storage Replace broken lens on light fixture. Install missing ceiling tiles. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15, 2000 Northampton High School KB#96079 Page 4 of 6 1514 eneral Classroom 'Install door stops. Install hardware on existing cabinet. Touch up paint at door header. Install missing duplex receptacle cover. Install fresh air intake grille louver at gravity damper. Install missing ceiling tile. UJ Top of marker board(wall)has to be finished 1515 eneral Classroom Install hardware at existing cabinet. Clean/repair tack strip at markerboard. Install missing ceiling tiles. tY Install rubber base at corner near unit ventilator. 15166 General Classroom C� Touch up paint at door frame. L/ Install missing ceiling tiles. Install unit ventilator face panel. Remove blue tape from wiremold. y Install fresh air intake grille louver at gravity damper. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 3 of 6 1507 General Classroom Install hardware on existing cabinet. `✓ Install face plate on unit ventilator. Clean tack strip on marker board at south wall of classroom. nstall missing ceiling tiles. Touch up header at window. 1508 General Classroom t ' Install fresh air intake grille louver at gravity damper. Install missing ceiling tiles. 1509 L/ Fix tile floor under computer counter 1512/1513 Small Classrooms a djust light sensors Repair trim at header at folding partition. i Remove tape from bottom of folding partition. ouch up paint at header at door in Rm 1512 Clean fingerprints on header over door. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Northampton High School KB#96079 Page 2 of 6 , �f Repair face of unit ventilator. Remove paint from wiremold at south wall of classroom. Paint cleat under computer counter. 1505 General Classroom Adjust wiremold at north wall of classroom. remove p aint at top of markerboard. � -z/Reinstall markerboard, poor seaming. Touch up wall at existing cabinet. /Touch up paint on wall at base. w Remove paint from wiremold at computer counter area. Repair VCT at south wall of classroom, east corner. Install fresh air intake grille louver at gravity damper. Install door from corridor to classroom. Replace damaged ceiling tiles. V' Marker boards need 1/4 x'/4 molding or caulking to finish 1506 eneral Classroom stall latch set on existing closet ut in paint at north wall of classroom at wiremold. Install missing ceiling tiles. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 MW J KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 15,2000 Addition&Renovations Northampton High School Northampton,MA Prepared By: Susan Sclafani KB#96079 Main Level Area E General Comments • Windows are not included in this punch list; however, note that several frames have been scratched, i.e. at wide mullion covers, true mullions, sash, etc. All windows are yet to be cleaned, including removal of adhesives, and screens installed.Blinds are to be installed as scheduled. Clean window sills. • Corridors are not included in this punch list. Installation of rubber and painted base has been addressed in a previous Field Observation Report. Locker installation is incomplete. Floors have not been cleaned. Adjust all devices in wiremold. General cleaning required, including light fixtures. a Remove protective plastic from all light fixtures. L/, Cut in paint at h.m. frames/caulk joint. All doors to be reviewed as this typically occurs at most frames. ! Install louvers at all gravity dampers. tom° Install silencers at all doors. Install sprinkler head escutcheons • The following rooms are not ready for punch list. 1522 SPED Conference 1509 General Classroom Install missing ceiling tiles. V Patch/caulk wall at north wall of classroom outlets. Install missing duplex receptacle cover plate. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 r KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 1, 2000 Addition and Renovations Northampton High School Northampton,MA Prepared By: Traci H. Milikowski K13#96079 Women's Toilet 1459 'Clutch and paint wall at electrical device below sink. Install lav guard at exposed sink piping. J~ ✓' Clan ceramic the floor, base, and all plumbing fixtures. 1f ,Remove overspray from hollow metal frame. 12 Install sprinkler head escutcheon and reset height. Corridor 1443 _ Remove painting tape from call for aid devices,west wall. v ' Paint outside corner near floor stop. Remove adhesive at south concrete block wall. t,. °-' Patch and paint east wall, south of Door 1445A. Patch and paint west wall below electric water cooler. Repair gouge in east wall across from Men's Toilet. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 1,2000 Addition and Renovations Northampton High School Northampton,MA Prepared By: Traci H. Milikowski KB#96079 Office 1449 i r" s Install blank plate at electrical device on east wall. Repair hole in gypsum board at door lock height. Office✓1448 1 i ]replace portion of dented 2' ceiling grid. 1 ,Patch and paint wall at light switch. r Repair hole in gypsum board at door lock height. Office 1447 i/� ,Repair hole in gypsum board at door lock height. Repair wall low at window. Workr om 1445 1, Patch and paint wall behind copier. :�z Patch and paint wall at light switch near sink. Repair gouge in wall at paper towel dispenser at east wall. Add clip at vertical wiremold at south wall. Men's Toilet 1460 Patch and paint wall at electrical device below sink. f Install lav guard at exposed sink piping. Clean ceramic tile floor,base,and all plumbing fixtures. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 1, 2000 Addition and Renovations Northampton High School Northampton,MA Prepared By: Traci H.Milikowski KB#96079 A.C. Office 1455 ,Adjust ceiling the and grid at window. Patch screw holes in gypsum board at south wall. ach gouge in gypsum board to _ L, Clean carpet at floor stop. k /' Add clip at vertical wiremold, north wall. � �ac Repair wall low at doorjamb,west wall. Patch and paint at receptacle and doorjamb at west wall. North Corridor and Entrance Vestibule Patch and paint wall at Door 1451 B. Clean all brick. - t , Inst _ all ceiling tiles. Return rubber base at north brick walls, to curtain walls each side. Conference 1451 Patch holes in west wall. Office 1 '50, /aintatdooijambs. Replace cut ceiling tile at south wall. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 0 KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 1, 2000 Addition and Renovations Northampton High School Northampton,MA Prepared By: Traci H. Milikowski KB#96079 L Adjust ceiling tile near northwest window. 1,-/Repair dent in base of north column. /Patch and paint gypsum board wall north of Door 1446. Reception 1446 Repair gouge in Door 1446. Clean door. Install silencers. Repair wall at Door 1451A. Finish wall around light sensor at west wall. f jj Finish paint high at north wall,and inside corners of east wall. j Clean exit sign. j Install missing ceiling tile. Patch and paint gypsum board above south hollow metal framed window and Door 1445B. St ora a 1463 7Install missing ceiling tile. Time Out 1454 L, Adjust ceiling the and grid at window. Patch east wall below light switch. i Remove scuff marks, low at south wall. Patch gypsum board at west wall light switch. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 r KAESTLE BOOS ASSOCIATES, INC. PUNCH LIST August 1, 2000 Addition and Renovations Northampton High School Northampton,MA Prepared By: Traci H. Milikowski KB 996079 Partial Main Level Area D (Interior round building-Guidance Suite) General k Touch up paint at all window stools. _ Caulk at all diffusers in window stools. s Remove plastic from all light fixtures. _ Trim out wall paint at all hollow metal frames. �Vacuurn carpet. Viewing 1458 Repair water damage at south wall near window. Clean electrical device cover plates. C--""P"aint electrical device cover at south wall to match adjacent plates. Career enter 1456 atch gypsum board below tackboard at north wall. Install light fixtures in gypsum board soffit at skylight. 'stall ceiling tiles at east side of skylight area. � /Install light trim at northeast side of skylight area. Clean joint compound from skylight. CONNECTICUT OFFICE MASSACHUSETTS OFFICE 416 Slater Road,P.O.Box 2590,New Britain,CT 06050-2590 124 Grove Street,Suite 215,Franklin,MA 02038 P: (860)229-0361 F: (860)229-5303 P: (508)520-9928 F: (508)520-0856 —=`7331 Ma M KAESTLE BOOS ASSOCIATES,INC_. ARCHITECTS August 3,2000 John A. Kaestle Mr. Robert Aquadro emeritus Aquadro & Cerruti,Inc. Texas Road Charles W.Boos P.O. Box 656 David W.King Northampton,MA 01061 Mark J.Weisman Michael J.Blessing Re: Addition &Renovations to M a ichRusty Malik Northampton High School Northampton MA Michael J.McKeon KB#96079 Jeffery R.McElravy Dear Mr. Aquadro: Christopher M.Roof Richard F.Webb Pursuant to my visit to observe work on August 1, 2000,enclosed is the Punch List. Jamie L. DiPinto Please advise me when this work is ready for a re-inspection. Vincent R.Amrhein Traci H.Milikowski Very truly yours, Scott J.Mangiagli Terry A.McDonald John W.Juros Traci H.Milikowski, RA Lawrence P.Trim Associate Scott D.Pellrnan KAESTLE BOOS ASSOCIATES,INC. THM:gh CONNECTICUT 416 Slater Road Enclosure P.O. Box 2590 New Britain,CT 06050-2590 c: Joseph Misterka(w/enc.) Phone:(860)229-0361 Lawrence Fink(w/enc.) Fax:(860)229-5303 William Letendre (w/enc.) MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 !-Mail:kba®kba-architects.com Web:www.kba-architects.com K:\Northampton\1000Ugh School\Ca\Punchlisu\aquadro0803009punchlist.doc p1010033.jpg(64Ox48Ox24bjpeg) t z Xr' � a 6 n p8 a> zt � /em+#g( 482#akGp2 �O p1010027.jpg(640x480x24bjpeg) t � R low f, s .a ',��s��s r.�5s 2�w�� xv S"` •�����,€,.������,atr3,.,'�.��� .�.��., Y.:i,,,l m,���.�' ��`.�� _���t.,.��ia�x.',£ p1010026.jpg(640x480x24b jpeg) IN, Ill c �� r & F 3 p p�pR` Y 5 Igo 'z p1010021.jpg(640x480x24bjpeg) � y %�d /@mm]@( 48 +#+mbi¢ F., 'Poll/ : §/ y . . . .�� a* . p1010019.jpg(640x480x24bjpeg) w F 2 trr rtk "�`��'����4✓��ar', kn�i� dF�"Y e k��+� �. C Y'r{ gIR4-11Wf . 3., a C � � 5 w g'r i k A 4 RIRR£ p1010018.jpg(640x48Ox24b jpeg) a S� dQ '�� 2 4 e�t✓ h '. p1010017.jpg(640x480x24bjpeg) g ,J. vj 1 w a �� T �s � p1010016.jpg(640x480x24bjpeg) t ?� 2�✓�' s r �P i $ , r ima t AN tymm"I no ,t ANY N� b i � F NORTHAMPTON HIGH SCHOOL Monitized Punch List Contractor Item Description r NE Landscape Landscape punch list from KBA dated September 15,2001. NE Landscape Landscape review May 2002. S Gibson Install several missing locks. Currently on order. Division 10 Replace interior building signage throughout. B-G Mechanical Label all ductwork in Boiler Room. — B-G Mechanical Complete air balancing. In progress. B-G Mechanical Building pressure test. B-G Mechanical Roof to AHU's and HRU's leak. B-G Mechanical Install gravity vent cover in room 113. B-G Mechanical Install return register in room 309. B-G Mechanical Balance fume hoods. Gibson being directly held up by B-G. Sagamore Sink in 318 does not drain properly. ° Sagamore vanZelm letter of July 16,2001,"Plumbing O&M Manuals" Items 1 &2. Sagamore New air tank does not have the appropriate nameplate. HFP Sprinkler Label piping throughout Boiler Room. HFP Sprinkler This company has not responded to the Phase Two issued punch Asts. Wayne Griffin Complete sound systems in the Grandstand,Cafeteria,Auditoem and Dramatic Arts. Wayne Griffin Complete the Media Retrieval System.- Wayne Griffin Install security magnets properly in all new exterior aluminum door leaves. ., Nayne Griffin Provide labels for MI cable in Boiler Room. Nayne Griffin vanZelm letter of July 16,2001,"Electrical O&M Manuals" Items 1,4&5. Nayne Griffin vanZelm letter of September 17,2001,"Electrical As-Built Drawings", Items 1,2&3. Nayne Griffin vanZelm letter of September 17,2001,"Signet As-Built Drawings", Items 1,2,3&4. Vayne Griffin Complete area of refuge station at door 14 A. Nayne Griffin Complete"Data and Video Cabling Systems"required documentation. _V E_ L _ _ OOD_�,' FCC L_ 1M_T=c H A N I C A L A N D E L E C T R I C A L E N G I N E E R S December 21, 2001 Ms. Traci H. Milikowski Kaestle Boos Associates, Inc. P.O. Box 2590 New Britain, Ct. 06050-2590 RE: Northampton High School- Final Punchlist Review vZH&S #96318.00 Dear Traci: On Thursday, December 13, 2001, a site visit was conducted to review the status of punchlisfitems that have been previously noted by our office. The following is a list of items still outstanding. These items are in addition to the Monetized Punch List(attached)that was recently compiled by Aquadro & Cerrutti, Inc. (see attached). 1. Revised as-built drawing of Boiler Room is still needed for Owner's record. 2. Seismic Bracing is loose on piping in Mechanical Room (near HRU-2). 3. Pump#6 in Boiler Room is very noisy. Should be checked. (Bad bearings?). 4. Electrical disconnect switch for Exhaust fan (EF-26) in Generator Room is in the "off' position. Why is this fan off? 5. Lightning Protection System- upon inspection of the system, the following was observed: a. Many of the cable mounting brackets have come loose from the roof and Air Handling Units (See attached photos). b. Cable splice fittings are rubbing on the roof membrane and could eventually create a leak in the roof(See attached photos). c. Some of the rooftop exhaust fans have not been connected to the Lightning Protection System (See attached photos). Should you have any questions, please contact me. Sincerely, �E MOOD & BRADFORD, INC. Bill Donald Field Engineer cc: Steve Krawczynski-vZH&S file MD:wjd PRINCIPALS SENIOR ASSOCIATE ROBERT B.HICKEY,P.E. RONALD W.POLASKE,P.E. DAVID G.WOOLLEY,P.E. ASSOCIATES DAVD W.MADIGAN,P.E. EDWARD D ALLEN,P.E. WILLIAM R.COSGROVE TOWN CENTER 29 SOUTH MAIN STREET WEST HARTFOR D,CT 06107-2420 STEVE S.KRAWCZYNSKI,P.E. SHASHI B.BANSAL.P.E. THOMAS A.WUNDER Voice:(860)521-4329 Fax:(860)521-5620 E-Mail:engineers Qvanzelm.com Webihttp://www.vanzelm.com WEBSTER M.GROUTEN,JR. Mr. Robert J. Aquadro -2- January 7,2002 Punch List dated September 5 2000 Although the painting of stair treads in the Area D and E stairs was discussed when it was found that the rubber tread/nosing detail could not be installed over the existing profile, I believe that the final solution only required painting of the steel risers and stringers. Please confirm. Also enclosed is correspondence from vanZelm Heywood & Shadford dated December 21, 2001 regarding outstanding items from the M/E/P Punch List. The work that remains for the lightning protection is assigned a value of$1000. Please notify me in writing upon completion of the remaining Punch List items. Very truly yours, ` Traci H. Milikowski, RA Associate KAESTLE BOOS ASSOCIATES,INC. THM:jdd Enclosure c: Joseph Misterka(w/enc.) CONNECTICUT Lawrence Fink(w/enc.) 416 slater Road Anthony Patillo(w/enc) P.O.Box 2590 Brett Jacobus(w/enc.) New Britain,CT 06050-2590 William Donald Phone:(860)229-0361 Fax:(860)229-5303 MASSACHUSETTS 124 Grove Street Suite 215 Franklin,MA 02038 Phone:(508)520-9928 Fax:(508)520-0856 370 Faunce Corner Road North Dartmouth,MA 02747 Phone:(508)998-2910 Fax:(508)998-2920 E-Mail:kba @kba-architects.com Web:www.kba-architects.com \WTSERV ER2\Data\Northampton\ArchStructlnt\CorrespondenceW quadro\Aquadro010702finalpunch.doc swommmoAlummumm s KAESTLE BOOS ASSOCIATES,INC. January 7, 2002 ARCHITECTS Mr. Robert Aquadro Aquadro &Cerruti, Inc. Texas Road P.O. Box 656 Northampton, MA 01061 Re: Addition &Renovations to Northampton High School Northampton MA KB#96079 Dear Mr. Aquadro: The enclosed Punch Lists have been reviewed on-site by Mr. Robert Lamontagne of this office and are either checked (4) as complete or designated with an "O" for incomplete. The majority of items is cosmetic and includes replacement of ceiling tiles, general painting and painting clean-up, casework adjustment, patching and repairs, and miscellaneous electrical items. Installation of fire rated caulking as well as general caulking is required in some areas. These items are assigned a value of$10,000. In general, each outstanding item is self-explanatory and does not require further CONNECTICUT direction. The items that follow require commentary in addition to the Punch List: 416 Slater Road P.O.Box 2590 punch List dated January 23, 2001 New Britain,CT 06050-2590 The scenery and curtain tracks have not been installed with the specified spacing of Phone:(860)229-0361 supports. Provide documentation that the supports provided meet the loading Fax:(860)229-5303 requirements of the curtains. MASSACHUSETTS I recall that the removal of the existing head blocks was discussed with the Owner. Our 124 Grove Street concern is that these head blocks are unsafe for any new rigging equipment and would be Suite 215 misused. It must be made clear that these head blocks are to be abandoned in place and Franklin,MA 02038 labeled such that they are not used in any way. Phone:(508)520-9928 punch List dated October 31, 2001 Fax:(508)520-0856 In correspondence dated December 21, 2000, 1 addressed the provision of a galvanized handrail system in lieu of the specified anodized aluminum railings, in order to obtain the 370 Faunce Corner Road code required maximum diameter of 1 t/2". The Owner subsequently deleted finish North Dartmouth,MA 02747 painting of all exterior galvanized railings in favor of exposed galvanizing as less Phone:(508)998-2910 maintenance. However, the galvanized railings on the Grandstand have now rusted and Fax:(508)998-2920 are to be either repaired or replaced. Please address this issue with a proposed solution, in writing. E-Mail:kba @kba-architects.com Web:www.kba-architects.com